Public Works Department-PWD has published Tender For Repair And Maintenance Of Various Items Installed At Maha Adhivakta Building, Prayagraj. Part O - Fire Fighting And Fire Alarm System For 6Th To 9Th Floor. Submission Date for this Tender is 23-02-2024. Alarm Systems Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42204287
Tender For Repair And Maintenance Of Various Items Installed At Maha Adhivakta Building, Prayagraj. Part O - Fire Fighting And Fire Alarm System For 6Th To 9Th Floor
Open Tender
Indian
Uttar Pradesh
prayagraj
23-02-2024

Tender Details

Tender For Repair And Maintenance Of Various Items Installed At Maha Adhivakta Building, Prayagraj. Part O - Fire Fighting And Fire Alarm System For 6Th To 9Th Floor

Key Value

Document Fees
INR 2354 /-
EMD
INR 721500.0 /-
Tender Value
INR 1.04 Crore /-

BOQ Items

Name of Work : - Repair and Maintenance of various items installed at Maha Adhivakta building, Prayagraj. (Part O - Fire Fighting and Fire Alarm System for 6th to 9th Floor)
Sl. No. Item Description
1Supply , erection and testing of ISI marked M.S.pipe (Class C and special etc. as per IS:1239 for above/under ground laying for hydrant system including transportation of material up to the worksite, fixing/laying of pipes including special i.e. bends tees, reducers flanges etc in proper position including all supports as per layout, by welding aligning the pipes lune, wrapping & Coating with Pyp coat etc providing taping for pressure gauge and for other instruments etc. cleaaning by water etc complete as per drawing & directgion of the engineer-in-charge. Make :- Tata / Jindal- Hissar/ SAIL [P.S. No. AR based on S/N 18.7 of DSR E/M 2022]
2150 mm Dia
3100 mm Dia
480mm Dia
550mm Dia
640mm Dia
732mm Dia
825mm Dia
9SITC of first and Hose reel drum with 20mm dia, 30Mtr long rubber pipe shut off nozzle, 25mm dia gate valve complete confirming to IS:884/444. Make: Safeguard/Firex/ Lifeguard/ G Tech/Firematic/ Safex/Atasee [P.S. No. As per part A Item No. 2, 3, 4, 5 and 6 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
10SITC of ISI marked single headed 63 mm dia SSHydrant Valve, comprising of 80mm dia flanged bend 63mm dia SS oblique pattern landing valve complete with blank cap etc. (Make: Safeguard/New Age/Lifeguard/ G Tech/Minimax/Safex/Atasee).[P.S. No. As per part A Item No. 2, 3, 4, 5 and 6 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
11SITC of RRL 63mm dia 15mtr long complete with SS coupling to IS:636. Make: Safeguard/Firex/Lifeguard/ G Tech/Firematic/ Safex/Atasee)[P.S. No. As per part A Item No. 2, 3, 4, 5 and 6 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
12SITC of SS branch pipe with nozzle 63mm dia confirming to IS:903. Make: Safeguard/Newage/Lifeguard/Minimax/ Safax/Atasee).[P.S. No. As per part A Item No. 2, 3, 4, 5 and 6 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
13SITC of Hose Box 0f 18SWG MS sheet with glass fronted door including locking appartment to accommodate 02Nos RRL hose & 01Nos SS branch pipe with nozzle.(External). Make :- Ceasefire / Newage /Minimax/HD/Tyco /Safeguard/ Superex/Atasee [P.S. No. As per part A Item No. 2, 3, 4, 5 and 6 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
14SITC of C.I. double flanged sluice valve complete with nuts, bolts & Washers etc. confirming IS780. Make: Kalpana/Aarko/Sir/Kartar/Kirloskar. [P.S. No. As per part A Item No. 17,16, and 24 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
15150 mm Dia
16100 mm Dia
17SITC of C.I. double flanged Non-Return valve complete with nuts, bolts & Washers etc. confirming IS780. Make: Kalpana/Aarko/Sir/Kartar/Kirloskar, for 150mm dia. [P.S. No. As per part A Item No. 17,16, and 24 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
18S/F G M Ball Valve 50 mm dia. Make Kalpana/Aarko/Sir/Kartar/Kirloskar. [P.S. No. As per part A Item No. 17,16, and 24 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
19Providing, installation testing and commisioning of non-return valve of 100mm dia confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. Make :- Kalpana/Aarko/Sir/Kartar/Kirloskar, [P.S. No. AR based on S/N 18.14.5 of DSR E/M 2022]
20Providing fixing testing and commisoining of 15mm dia quartzoid bulb type pendent sprinklers of rating 68 degree c with required accessories. Make:- Grinnel- Tyco / Viking / HD/ Atasee [P.S. No. AR based on S/N 18.21.1 of DSR E/M 2022]
21SITC of sprinkler flexible pipe (UL listed) of stainless steel complete with 15NPT on reducer thread with working pressure of 175PSI test pressure of 875PSI (burst) with branch line (inlet) 25mm NPT male thread to sprinkler head (outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, centre bracket stockbar of 700mm size as required. Make :- Eversafe /Newage/Tyco/Viking[P.S. No. AR based on S/N 18.25.1 of DSR E/M 2022]
22SITC of electric driven terrace pump suitable for automatic operation consisting of following complete in all respects. (A) Supplying, installation, testingand commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete inall respects, as required:(Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steelshaft, mechanical confirmingto IS :1520 (C)  Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontalfoot mounted type with Class-"F" insulation,conforming to IS-325. (D)  M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads. For 450lpm 35m head. Make :- Kirlosker/ Willo/ KSB [P.S. No. AR based on S/N 18.4.2 of DSR E/M 2022]
23Supply and fixing of PVC tank with cover and suitable locking arrangement having 5000 litre capacity@6.10 per litre. [P.S. No.Item No- 1649 of DSR 2021 Vol-1]
24Dismentaling of all damaged pipes, sprinklers, fire fetectors and wiring etc on all foor floors. [P.S. No. Q/R]
25Fire Alarm System
26SITC of Manual Call point break glass type housed in MS sheet including connection. Make: Honeywell-Notifier/ Siemens/ Apollo/Agni/Daksh. [P.S. No. As per part B Item No. 1 & 2 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
27SITC of Electronic LMT hooter housed in MS housing suitable for wall mounting/ceiling including making connection. Make:- Honeywell-Notifier/ Siemens/ Apollo/ Agni/Alpha/Daksh.[P.S. No. As per part B Item No. 1 & 2 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
28S/W of submain with 3No. 1.5Sq.mm. PVC insulated 1100V Grade single core Cu conductor cable in 20mm dia heavy gauge rigid steel/PVC conduit on surface complete in all respect. Wire Make :- Havells/ KEI/ R.R. Kabel/ Finolex/ Polycab [P.S. No. As per part B Item No. 10 & 6 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
29Supplying, Installation, Testingand commissioning of ResponseIndicator pull standing type including making connection with wire. Make :- Morlay/ Seimens Finder/ GE Edwards/ Honeywell- Notifier/Advanced/ Apollo[P.S. No. As per part B Item No. 10 & 6 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
30Supplying, Installation, Testingand commissioning of Ionization SmokeDetector as per fire specification including making connection with wire. Make - Honeywell-Notifier/System Sensor/ Edward/ FST/ Apollo/Advanced. [P.S. No. As per part B Item No. 8, 5 & 12 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
31SITC of 6 Zone Fire Alarm local control panel for above, complete in all respect with Auto display. Make - Agni/Alpha/Daksh/Honeywell-Notifier/ Siemens/ Apollo/ Advanced/ [P.S. No. As per part B Item No. 8, 5 & 12 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
32S/L of 6core Copper cable for connect LCP to Main pannel with PA system. Make:- Havells/ R.R. Kabel/ Polycab/ KEI [P.S. No. As per part B Item No. 8, 5 & 12 of Letter No. 3228(1) EM/13E W-CE(E/M) - Fire/14-15, Dt. 18-11-14]
33Fire Extinguisher Cylinders
34Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. [P.S. No. 1132]
35Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. [P.S. No. 1131A]