Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | R.c.c. workwith cement approved coarse sandand2cm. (3/4\") guageapproved stoneballastin the proportion 1:1.5:3,(1cement :1.5corse sand 3 grit) in lintels of doors and windows excludingsupply of reinforcement and its fixing and bending but including its fixing and bindingthe same necessarywith 24 BWG bindingwireand including necessary centeringand shuttering etc.and also including supply of all materials,labour andtools and plants etc, required forproper completion of the works. The rate excludes making of drip course which shall be paid extra excluding GST.PWD-283 |
| 2 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in slab excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. |
| 3 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lighter beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. |
| 4 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in Column excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. |
| 5 | 1st Class brickwork in 1:6 cement & coarse sand of 1.50 fineness modulus mortar insuper-structure including necessarycutting andmouldingofbricksrequiredandalsoincludinghoney comb brick workthickness of wall more than one brick and for extra labour to above items |
| 6 | 1st Class brick(M-150) work in 1:4 cement & coarse sandcement of 1.50 fineness modulus mortar insuper-structure including necessarycutting andmouldingofbricksrequiredandalsoincludinghoney comb brick workthickness of wall more than one brick and for extra labour to above items |
| 7 | Providing and laying \"Brick coba\"12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other,over 20mm thick base ofcement mortar 1:4 cement and coarse sand mixed with water proofing compound.spreading cement slurry mixed with acrilic cement concrete water proofing compoundfilled gapes of coba and top of coba mortar with water proofing compound in 1:4 cement and coarse sand mortar. All above operations to be done in order and as directed and specified by the Engineer-in-Charge With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 8 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 9 | Mild steel or iron workofsmall sizes and sections suchand holding down bolts, holdfasttierods,gratings etc. ( when notincludedinan overall rates) wroughttorequiredfromincluding supply ofsteel anditswastage includingcostof bolts, nuts if required forandwelding, grinding and making holes as required completion of workfabricationofholesdoors, chaukhats nosing. Fabrication of holdfastfordoor chaukhats and windows. |
| 10 | M.S. Grill |
| 11 | M.S. Z-section fixed panels |
| 12 | M.S. Z-section openable panels |
| 13 | M.S. Angle iron 40X40X5 MM |
| 14 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 15 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia |
| 16 | FixingofM.S.Chaukhats (a) Door chaukhats |
| 17 | (b) Window chaukhats up to 1.5 sqm |
| 18 | (c) Ventilator chaukhats |
| 19 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennot includedin anover all rates )wroughttorequired shape as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured upto floor two level. |
| 20 | 12mm thick plaster with cement mortar in proportion of 1:6 cement & Coarse sand |
| 21 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 22 | Making grooves 10 to 12mmwidex 8mm deep in plaster of the wallor in ceiling vertically or horizontally as required. |
| 23 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 24 | Providing and laying 8 to 10 mm thick ivory or light shade vitrrified tiles of 600 x 600 mm size in flooring or skirting laid with 1:3 cement mortar finished with cement slurry & with pigment grouting & polishing complete I/C S/O all material labour T&P etc. required for proper completion of the work.excluding base concrete. |
| 25 | 25mm thick KOTA stone slab flooringover 20mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab includding rubbing and polishing complete with base of cement mortar. |
| 26 | Kota stone 10 to 12 mm thick in skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 27 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 28 | Supply and fixing 6mm (1/4\") thick china white glazed tilesin flooring or in skirting or dado laid with 1:3 cement and approved course sand mortal finished with white cement slurry jointing and polished complete including supply of all materials labour T & P etc. required forpropercompletionofthe work. |
| 29 | Painting roofs or other iron work in large areas with one coatpriming paint and two coat of approved superior quality paint including supply of all materials , labour & tools and plantsetc. required for propercompletion of work . Paint to be used ISI marked. |
| 30 | Painting or varnishing work in small areas or new woodwork with one coat (upto one square metre of ready mixed priming paint and one coat of approved superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used ISI marked. |
| 31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 32 | Distempering (Two coat) with oil bound distemper of approvedbrandandmanufacture&ofrequiredshadeon undecoratedwallsurfacetogiveanevenshadeover& includingaprimingcoatwithcementprimerofapproved brand & manufacture such as Berger,J&N, Shalimar, Asian paints afterthoroughlybrushing the surface free from mortardroppings&other foreignmatters&alsoincluding preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. |
| 33 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 34 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : With 4.0 mm thick glass panes. |
| 35 | Providing & fixing stainles steel door bolts ISI marked required colour or shade with nuts and screws etc complete.250x16 mm |
| 36 | Providing & fixing stainles steel tower bolts ISI marked to required colour or shade with necessary screws etc complete.250x10 mm |
| 37 | Providing and fixing stainless steel handles ISI marked to required colour or shade with necessary screws etc complete. 125mm |
| 38 | Providing and fixing stainless steelhanging floor door stopperwith necessary screws etc. complete.Twin rubber stoper |
| 39 | Providing and Fixing of Door slincer including necessary screws etc complete |
| 40 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 41 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. |
| 42 | Providing and laying A.A.C. Blockin toilet sunken area including supply of materils welding labour tools and plants etc complete as per instruction of Engineer Incharge. |
| 43 | Sanitary & Water Supply Work :-Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting and fixtures completed including cutting and making good the walls and floors wherever required. |
| 44 | White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 45 | Providing & fixing white viterous china wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standardpattern, including painting of fitting and brackets, cutting & making good the walls wherever required.Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap |
| 46 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.32 mm dia (for wash basin & sink) |
| 47 | 40 mm dia (for wash basin & sink) |
| 48 | Providing & fixing stainless steel AISI 304 (18/8) kitchen sink with drain board as per IS :13983 with C.I. bracketsandstainless steel plug 40 mm including painting of fittings and brackets cutting and making good the walls wherever required.510x1040 mm bowl depth 178 mm |
| 49 | Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 50 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredc) Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern |
| 51 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredd) Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern |
| 52 | Soil Waste & Vent Pipes And Fittings :-S/F of upvc SWR Pipe Type -B confirming to IS -13592 incluiding jointing the pipes with rubber ring lubricant and UPVC SWR Cuplar confirming to IS 14735 also inluiding excavation of treches cutting of walls and holes and repairing of walls , floors and refilling the trenches as before cut including cost of other fittings such as door band, T and YT including supply of all materials labour and t&p required for prper complition of the work. 110mm dia SWR Pipe |
| 53 | 90mm dia SWR Pipe |
| 54 | Providing & fixing SWR PVC clamps i/c supply of material tools & plants labour etc. an as per instruction of Engineer-In-ChargeFor 110 mm dia pipe |
| 55 | For 90 mm dia pipe |
| 56 | S/F of upvc SWR Nahani Trap size100/90mm confirming to IS -14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. 110mm dia |
| 57 | Providing & fixing Sand Cast iron SWR coupler110 mm dia |
| 58 | 90 mm dia |
| 59 | Providing & fixing sand cast iron SWR bend i/c supply of material tools & plants labour etc. an as per instruction of Engineer-In-Charge.110 mm dia |
| 60 | 90 mm dia |
| 61 | Providing & fixing SWR Tee i/c supply of material tools & plants labour etc. an as per instruction of Engineer-In-Charge.110 x 110 x 110 mm |
| 62 | 90 x 90 x 90 mm |
| 63 | Providing & fixing SWR Terminal Guard i/c supply of material tools & plants labour etc. an as per instruction of Engineer-In-Charge.110 mm dia |
| 64 | 90 mm dia |
| 65 | Providing and fixing 110 mm dia PVC rain water pipes 6 kg/cm sq. i/c all fittings for proper completion of work as per direction of Engineer in Charge. |
| 66 | Water Supply Pipes And Fittings :-Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work exposed on wall20mm nominal outer dia pipes |
| 67 | 20mm nominal outer dia pipes |
| 68 | 32mm nominal outer dia pipes |
| 69 | 50mm nominal outer dia pipes |
| 70 | Painting G. I. pipesand fittingswith synthetic enamel white paint over a ready mixedpriming coat, both of approved qualityfornew work.20mm dia nominal bore |
| 71 | 25mm dia nominal bore |
| 72 | 32mm dia nominal bore |
| 73 | 50mm dia nominal bore |
| 74 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall a) 32mm dia nominal outer dia pipes |
| 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.a) 15mm dia nominal outer dia pipes |
| 76 | b) 20mm dia nominal outer dia pipes |
| 77 | c) 25mm dia nominal outer dia pipes |
| 78 | Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end)25 mm nominal bore |
| 79 | 32 mm nominal bore |
| 80 | 50 mm nominal bore |
| 81 | Providing and fixing ballvalve (brass) of approved quality complete. (High or low pressure with plastic floats).25 mm nominal bore |
| 82 | Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. |
| 83 | Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. |
| 84 | Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. |
| 85 | Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. |
| 86 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and makingnecessaryholes for inlet, outlet and overflow pipes but without fittingandbasesupportfor tank.8000 litres capacity |
| 87 | Providing and fixing white vitreous china urinal partition for half stall urinals. (Parryware, cera, hindware or equivalent) |
| 88 | Providing600 mm long C. P. brass towel railcomplete with C.P. brass brackets |
| 89 | Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. |
| 90 | Wiring points for light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduitpipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire,piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc.complete in all respects.as directed including matching colour wash. |
| 91 | Wiring points for two way light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduitpipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire and two number two way piano type switches & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc.complete in all respects.as directed including matching colour wash. |
| 92 | Wiring points for Fan /Fresh air fan (light duty exhaust fan )with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduitpipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire,piano type switch & ceiling rose on 3mm thick phenolic paminated backalite sheet etc.complete in all respects.as directed including matching colour wash. |
| 93 | Wiring points for Plug with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduitpipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire,piano type switch & socketsheet etc.complete in all respects.as directed including matching colour wash. |
| 94 | Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable inPVC conduitpipe partly concealed including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C. |
| 95 | Supply and wiring of submain with two number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in20mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 2.5 Sqmm FR PVC Multistand copper earth contunity wire including colour wash etc. complete in all respects. |
| 96 | Supply and wiring of submain 2 number 6 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 4.0 Sqmm FR PVC Multistand copperearth contunity wire including colour wash etc. complete in all respects. |
| 97 | Supply and wiring of submain with 4 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in32 mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects. |
| 98 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWG MS. Sheet incorporating 10mm dia, M.S. round bar duly bent for supporting fan hanger dully painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C roof before concreting along with supply of all materials,labour. T& Petc. required for proper completion of the work. |
| 99 | Supply & fixing of single wall bracketon matching M.D.F.E.G.boardbase etc. complete in all required. Cat. AA |
| 100 | Supply & fixing of fancy type round ceiling fitting made of polycarbonate for and with 1x 15/18 watt CFL complete in all respects. Cat. AA |
| 101 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light complete including tube etc. on surface complete in all respect.1 X 22 W CAT-AAA |
| 102 | 2 X 22 W CAT-AAA |
| 103 | Add for fixingof tube fitting as pendent with two no. 19 mm dia 16 gauge rigidsteel conduit double check nuts spring loaded flanges or M.S hook fabricated from 25mm x 3 mm flat ironduly groutedin the ceiling upto3.5 hieght of ceiling including painting with synthetic enamel paint along with supply of all materialslabour T & P etc.. Requiredfor proper completionof work . |
| 104 | Making hole in the wall for exhaust fan and finishing prperly complete in all respects. |
| 105 | Supply and erection of AC 1200mm sweep ,230/250 Volts,50Hz ceiling fan without regulator standard down rod ,blades including connection etc. completeas required as per direction of E/I Make Bajaj,Crompton or equivalent. |
| 106 | Supplyfixingofelectronic fan regulator (Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. |
| 107 | Supply & erection ofA.C 230/250 Volts,50 Hz exhaust fans including providing m.S bolts,mounting frame and other acessories including connections etc.complete as required300mm sweep as per directionof E/I Makebajaj,Cromption or Equivalent. |
| 108 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve6 - 32 amps.Cat. A |
| 109 | Supply and fixing of 40/63 Amp MCB(10KA)C Curve 40 Amp. 4 Pole MCB Cat. A |
| 110 | 63 Amp. 4 Pole MCB C Curve-Cat. A |
| 111 | Supply and fixing of flush/surface mounting distribution boardswith additional metal door without MCBcomplete in all respects. 4 Way TPN Cat. A |
| 112 | 6 Way TPN |
| 113 | Supply and fixing of power plug with 15 Amp./250 Volt flush type universal switch and 5 pin 15 A/250 Vflush type universal socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. |
| 114 | Supply & fixingof Sheet Steel Enclosure Surface/ Flush Mounting fitted With 20/32 Amp. 2Pin and earth metal clad scraping earth plug and socket complete in allrespects as per direction and satisfaction of engineer-in-charge.-Cat. A |
| 115 | Supply and fixing of 63 A 415 V metal clad TPN CFS complete with HRC fuse etc. on angle iron frame complete in all respect . |
| 116 | Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. |
| 117 | Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. |
| 118 | Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects. |
| 119 | S/F of change over switch on angle iron frame ,including the cost oflabour,T&P painting and other material required for proper completion of the work asper direction&satisfaction of E/I 320 Amp. Four pole on 50 mm x 50 mm x 6 mm angle iron frame. |
| 120 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used. All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T.PanelIncoming : One (1) No 315A 4 pole MCCB Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-315A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No.315 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 100Amps TPN- 3 NosOR outgoing as per site requirment |
| 121 | Supply and laying of aluminium conducter PVC insulated armoured served sheathed cables 1100 volts grate at a depth of below ground lvl overa cusion of 75 mm thick sand alroundand protected with burnt on side and on top ,On surface the cable run shallbe fixed on M.S clamps etc. of suitable size or as directed by E/I complete in all respects,The armouring of the cable shall be properly connected with the earth conductor by clamps atc.(i) 10 Sq. mm 2core |
| 122 | (ii) 16 Sq. mm 4 core |
| 123 | (iii) 70 Sq. mm 3.5 core |
| 124 | (iv) 120 Sq. mm 3.5 core |
| 125 | Supply 7 fixing of plain or pin type copper tin plated cable socket to the cable leads, insulated with tape and making connection etc. complete in all respect as per direction of E/I(i) 10 Sq. mm |
| 126 | (ii) 16 Sq. mm |
| 127 | (iii) 35 Sq. mm |
| 128 | (iv) 70 Sq. mm |
| 129 | (iv) 120 Sq. mm |
| 130 | Internal Hydrant SystemSITC of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex) DSR-18.9.1 |
| 131 | SITC of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC) DSR- 18.16.1 |
| 132 | SITC of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex) DSR-18.18.1 |
| 133 | SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle |
| 134 | Providing and fixingMS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or RCC walls and making good complete. (For Riser) DSR-18.8.7100mm dia |
| 135 | Supply, installation, testing and commissioning of Manual Swing Type First aid Fire Hose Reel conforming to IS: 444 complete with all other necessary fixing accessories. DSR -18.17.2 |
| 136 | Supply of Fire Man Axe. |
| 137 | Providing and fixing weather proof standard Fire Duct Door complete in all respect for internal. |
| 138 | SITC of Air cushion Tank (2000x1000)mm. |
| 139 | SITC of Air Release Valve. |
| 140 | Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. DSR -16.11.2.2 150 mm |
| 141 | SITC of Butterfly Valve complete with all respect. DSR-16.11.1.2 150 mm |
| 142 | Supply, Installation, Testing & Commissioning of Pressure Gauge with gauge cock DSR-16.8 |
| 143 | Supply, Installation, Testing & Commissioning ofFire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet. 2 way |
| 144 | Supply, fixing , testing & commissioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump)(Make : Kirloskar/Mather+Platt) (a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. (b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class \"B\" insulation for the above pump and flexible coupling with the pump.The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it\"s rated discharge at 65% of rated head. (c) Common bed plate of fabricated mild steel channel or cast iron type. (d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc. (e) Pressure switch for automatic operation of motor including necessary wiring upto control panel. (f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT\"s protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details. Discharge :450 liter per minute. Head : 35 meter |
| 145 | Supply and fixing of ABC type (4 kg.) ISI Marked1131 |
| 146 | Supply and fixing of CO2 gas type (4.5 kg.) ISI Marked 1132 |
| 147 | Supply and fixing of self glow type exit signage |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy