| 1 | Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I. |
| 3 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 4 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 5 | 1:2:4 (1 cement : 2 coarse sand (zone - III) 4 graded Stone aggregate 20 mm nominal size) |
| 6 | 1:3:6 (1 cement : 3 coarse sand (zone - III) 6 graded Stone aggregate 40 mm nominal size) |
| 7 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III) 3 graded Stone aggregate 40 mm nominal size) |
| 8 | Centering and shuttering including strutting,propping etc. and removal of form for :- Foundations , footings,bases of column , etc for mass concrete |
| 9 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III) 3 graded Stone aggregate 40 mm nominal size) |
| 10 | Centering and shuttering including strutting,propping etc. and removal of form for :- Foundations , footings,bases of column , etc for mass concrete |
| 11 | Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth curing, taxes and royalty all complete as per building specication and direction of E/I. |
| 12 | Providing and layingdamp proof course 50 mm thick with cement concrete 1:2:4 (1 cement :2coarse sand (zone - III) : 4 graded stone aggregate 20 mm nominal size. |
| 13 | Providing Designation 100AB/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9\"x4.5\"x3\") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 14 | Reinforced Cement concrete woek in beams,suspended floors,roofs having slope up to 15* landing,balconies,shelves,chajjas,lintels,bands,plain window sills staircases and spiral stair cases above plinth level up to floor five level , excluding the cost of centering , shuttering,finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand (zone - III):3 graded stone aggregate 20 mm nominal size. (Band at Lintel) |
| 15 | Centering and shuttering including strutting,propping etc. and removal of form for :- Lintels,beams,plinth beams,girders,bressumers and cantilevers |
| 16 | Reinforced Cement concrete woek in beams,suspended floors,roofs having slope up to 15* landing,balconies,shelves,chajjas,lintels,bands,plain window sills staircases and spiral stair cases above plinth level up to floor five level , excluding the cost of centering , shuttering,finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand (zone - III):3 graded stone aggregate 20 mm nominal size. (Lintel) |
| 17 | Centering and shuttering including strutting,propping etc. and removal of form for :- Lintels,beams,plinth beams,girders,bressumers and cantilevers |
| 18 | Reinforced Cement concrete woek in beams,suspended floors,roofs having slope up to 15* landing,balconies,shelves,chajjas,lintels,bands,plain window sills staircases and spiral stair cases above plinth level up to floor five level , excluding the cost of centering , shuttering,finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand (zone - III):3 graded stone aggregate 20 mm nominal size.(Tie Beam) |
| 19 | Centering and shuttering including strutting,propping etc. and removal of form for :- Lintels,beams,plinth beams,girders,bressumers and cantilevers with water proof ply 12 mm thick |
| 20 | Reinforced Cement concrete woek in beams,suspended floors,roofs having slope up to 15* landing,balconies,shelves,chajjas,lintels,bands,plain window sills staircases and spiral stair cases above plinth level up to floor five level , excluding the cost of centering , shuttering,finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand (zone - III):3 graded stone aggregate 20 mm nominal size. (Roof Slab) |
| 21 | Centering and shuttering including strutting,propping etc. and removal of form for :- Suspended floors,roofs,landing, balconies and access platform with water proof ply 12 mm thick |
| 22 | Reinforced Cement concrete woek in beams,suspended floors,roofs having slope up to 15* landing,balconies,shelves,chajjas,lintels,bands,plain window sills staircases and spiral stair cases above plinth level up to floor five level , excluding the cost of centering , shuttering,finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand (zone - III):3 graded stone aggregate 20 mm nominal size. (Chajja) |
| 23 | Centering and shuttering including strutting,propping etc. and removal of form for :- Weather shade, Chajjas, corbels etc. including edges |
| 24 | Supplying fitting and fixing 20 gauge G.C.I. Sheet (Door & Window) gate on M.S.angle frame of size 60*60*6mm, including cost of fabrication providing necessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size, applying a prim ing red lead paint over steel work,taxes all complete as per specification and direction E/I. |
| 25 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specification and direction of E/I. |
| 26 | Providing 25 mm thick first class patent stone flooring (1:2:4)with stone chips in two layers, bottom layer 19mm thick (1:2:4) with 12 mm to 6mm size graded stone chips and top layer 6 mm thick (1:2:4) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction ofE/I |
| 27 | Providing 12 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 28 | Providing and fixing fan hook of 16mm diaM.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab beam at the time of casting all completeas perbuilding specification and direction of E/I. |
| 29 | Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly includingcost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.) |
| 30 | Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 31 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 32 | Providing 12mm thickcement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with flor, curing, taxes and royalty all complete as per building specification and direction of E/I |
| 33 | Providing 12mm thickcement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 34 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l. |
| 35 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 36 | 110 mm diameter |
| 37 | Bend 87.5°110 mm dia |
| 38 | Shoe (Plain) 110 mm dia |
| 39 | Single tee with door |
| 40 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 41 | 8 mm dia |
| 42 | 10 mm dia |
| 43 | 12 mm dia |
| 44 | 16 mm to 20 mm dia |
| 45 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgroutedwithfinesand,includingnecessaryexcavation,levelling& dressing & finishing the top smooth. |
| 46 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 47 | Group C |
| 48 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 49 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 50 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 51 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 52 | Supplying and fixing 3 pin 5 amp. Ceiling rose on the existing junction box/wooden block including connection etc. as required |
| 53 | Supplying and fixing batten/angle holder including connection etc. as required |
| 54 | Installation, testing and commissioning of pre-wired, flourescent fitting/ compact fluorescent fitting of all type complete with all accessories and tubes etc. direcly on ceiling/wall including connection with 1.5 sq. mm FRPVC insulated, copper conductor, single core cable and earthing as required. |
| 55 | I.T.C. of ceiling fan incluing wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm FRPVC with 1.5 sq.mm FRPVC insulated copper conductor single core cable etc. as reqd. |
| 56 | 20 mm PVC Conduit |
| 57 | 5/6 amps, one way switch |
| 58 | 3 Pin 5/6 amps, socket outlet |
| 59 | 170 mm x 221 mm x 48 mm deep / (8\" x 10\") |
| 60 | 8 waydouble door |
| 61 | 6/32 amps, single pole of \"B\" Series |
| 62 | 40 amps, single pole of \"B\" Series |
| 63 | 6/32 amps, D.P. |
| 64 | Supply of Ceiling Fan 48\" (1200 mm)as required |
| 65 | Supply of 15/16 Watt L.E.D Bulb |
| 66 | Supply of Batten (20/22W) |
| 67 | Carriage of materialsSand |
| 68 | Stone chips |
| 69 | Stone metal |
| 70 | Brick |
| 71 | G.S.T @ 18% |
| 72 | Labour Cess 1% |