Panvel Municipal Corporation has published Tender For Providing And Installing Traffic Signaling System At Various Location Within Jurisdiction Of Panvel Municipal Corporation For Regulation To Traffic Under Development Of Urban Transportation Of Infrastructure.(Dpdc Scheme). Submission Date for this Tender is 23-02-2024. Traffic Signals Tenders in Raigad Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Feb-2024 | Pre Bid Queries | Technical Bid | 23-02-2024 |
Sl. No. | Item Description |
1 | Lumpsum charges per signal for monthly Preventive & Corrective Maintenance of Road Traffic Signals – Isolated junctions. Per Month per junction ratesA. Preventive Maintenance a.Regular preventive maintenance of Traffic Signal System involving external and internal cleaning of the controllers, cleaning of the signal aspects, poles, junction boxes etc. once in fortnight, tightening of all the screws of the controllers, poles etc.B. Corrective Maintenance a. Taking corrective action for electrical/electronic failures inside thecontrollers/poles /Aspects etc. b. Repairing of LED"s PCBs etc. c. Controller programming / reprogramming. d. Repairing / replacement of faulty / defective spare parts of the controller including repairs of various cards etc.Signal Junctions |
2 | Supply of Microprocessor based Automatic traffic signal controller with housed in a water proof, dust proof & dust tight cabinet with internal locking arrangement , Police panel etc., incorporating the following – minimum 16 timing plans & 12 phases, 7 dayclock, with 16 groups with minimum 48lines with conflict management facility and GPS clock system |
3 | Supply of controller cabinet for controllers of M.S. Sheet material of 2 mm thickness with I.P.-65 protection having size of 600X300X1200 mm (WXDXH) |
4 | Installation & commissioning of Traffic Signal Controller Including all Fittings on PCC foundation.( Excluding PCCfoundation). |
5 | Installation and commissioning of contdown timer for Signal Junctions |
6 | Supply of count down timer (2 1/2 digit 8" digit height dual colour) for non-ATC Signal Junctions as per latest IS, BS or equivalent standards |
7 | Supply of single120mm (OD)/100 mm (ID) DWC HDPE Pipes conforming to the IS 14930 (Part-II) including supply of necessary sockets, couplings etc. |
8 | Laying of single 120mm (OD)/ 100 mm (ID) DWC HDPE Pipes including pull wire along with necessary sockets, couplings etc. |
9 | Supply of single 50 mm (OD)/ 37 mm (ID) double walled corrugated High Density Poly Ethylene (HDPE) Pipes conforming to the IS 14930 (Part-II) including supply of necessary sockets, couplings etc |
10 | Laying 50 mm (OD)/ 37mm (ID) double walled corrugated High Density Poly Ethylene (HDPE) Pipes including pull wire along with necessary sockets, couplings etc |
11 | Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
12 | Laying of 50 mm Dia. Class "A" G.I. pipe, with provision of pull boxes etc. |
13 | Supply of Traffic signal Straight poleof 6 mtr, inner dia 100 mm from resistant to peeling with base plate size of ( LXWXT) 200mm X200mmX10mm painted with redoxide and double coat with synthetic enamel paint of yellow colourassembly G.I., class B, |
14 | Supply of 2 mm thick 310 mm x 215 mm x 100 mm MS junction box including providing cover with provision to adjust overall height, knock outs on four sides to accept cables of specified sizes and including elmex connector, gland, cable terminations etc |
15 | installation of 2 mm thick 310 mm x 215 mm x 100 mm MS junction box as described above |
16 | Supply of power supply box 600mm X 400mm X 300mm (HXWXD), with canopy made in welded construction of S.S. 304 material having sheet of thickness 1.6mm with IP 55 protection as per technical specification and as per requirement of power supply authority |
17 | Installation & commissioning of power supply box. |
18 | Supply of Polycarbonate LED Signal head housing 300 mm dia. alongwith brackets & accessories etc. (For all type of LED Retrofit) |
19 | Supply of 300 mm dia – signal LED retrofit - Red (blow) with minimum light output 260Cd and maximum power consumption 10W ±10%, with IP-65 protection |
20 | Supply of 300 mm dia – signal aspect – LED retrofit - Amber (blow) with minimum light output 260Cd and maximum power consumption 10W±10%, with IP-65 protection |
21 | Supply of 300 mm dia – signal aspect – LED retrofit - Green (arrow/U- Turn) with minimum light output 100Cd and maximum power consumption 4W±10%, with IP-65 protection |
22 | Supply of 300 mm dia – signal aspect – LED retrofit - Red (ped. standing) with minimum light output 65Cd and maximum power consumption 4W±10%,with IP-65 protection |
23 | Supply of 300 mm dia – single aspect – LED retrofit - Green (ped.walking) with minimum light output 45Cd and maximum power consumption 4W±10%,with IP-65 protection |
24 | Installation of Polycarbonate LED Signal aspect of 300 mm dia. on standard traffic signal straight pole & Cantilever Pole |
25 | Supply of PVC insulated armoured cable - 1.0 Sq.mm. 8 core copper conductor |
26 | Supply of PVC insulated armoured cable - 1.0 Sq.mm. 16 core copper conductor1.5 Sq.mm. 16 core copper conductor |
27 | Laying of signal cables in trenches, existing ducts / G.I. Pipes including ferruling, testing etc. but excluding any cable joint, excavation etc. |
28 | Excavation of trench for traffic signalscables and conduiting as per requirement of the signal junction up to the depth of 1000mm below the ground surface and width 500mm in the Carriage way (Asphalt/ Mastic Asphalt/ paver block) including refilling of the trench in carriage way and removal of debris. |
29 | Excavation of trench for traffic signals and VMS boards cables and conduiting as per requirement of the signal junction up to the depth of 1000mm below the ground surface and width 500mm in the Carriage way (Cement Concrete) including refilling of the trench in carriage way and removal of debris. |
30 | Excavation of trench for traffic signals and VMS boards cables and conduiting as per requirement of the signal junction up to the depth of 600mm below the ground surface and width 500mm in the footpath/soft soil including refilling of the trench in footpath and removal of debris. |
31 | Erection of signal pole in 60cm x 60cm x 12cm deep pit with 1:1:5:3 cement concrete & providing coping of 30 cm dia in c.c plastering finishing curing including providing local earthing with G.I. wireloop etc for 6 mtr long pole |
32 | Construction of signal controller foundation upto 600mm height above ground level and 600 mm below ground level on C.C. M20 grade pedestal, having size (LXBXH) with fixing of SS304 nut bolts for controller cabinet & Power supply box cabinet |
33 | Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 2500 VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV |
34 | Supplying and erecting 12 V/100Ah tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete |
35 | Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as perspecification no. EA-EP |
36 | Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected withglands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. CB-LT/AL |
37 | Installation & Commissioning of New type LED cantiliver Traffic Signal pole including Transportation from MCGM Depot to signal location (excluding foundation) |
38 | Construction of foundation for New type LED cantiliver Traffic Signal pole including foundation bolts as per technical specification and drawing |
39 | Fabrication, Supply of New type LED cantiliver Traffic Signal pole of GI ERW square pipe including 6 Nos of LED Modules, fixtrues, control units, drivers, relays, wires, cables, necessary accessories, transportation of pole to PMCand as per the technical specifications and drawings |
40 | Making Horizontal Directional Drill / Bore of 150 mm dia and depth up to 1.5 mtr in soft soil and laying 150 mm HDPE/GI pipe etc. complete as per specification no. CW-EXN-CTR |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail