}

Tender For Provision Of Briefing Hall And War Gaming Centre At Caw, hakimpet-Telangana

Military Engineer Services-MES has published Tender For Provision Of Briefing Hall And War Gaming Centre At Caw. Submission Date for this Tender is 14-05-2024. Nozzle Tenders in hakimpet Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

42119118
Corrigendum : Tender For Provision Of Briefing Hall And War Gaming Centre At Caw
Open Tender
Indian
Telangana
hakimpet
14-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of Briefing Hall And War Gaming Centre At Caw ; 1 General Summary Note: Schedule ‘A’ Part I To Xiv Are Prepriced By Mes Under Ser No. 1 To 13. Bidders Shall Insert Their Lumpsum Amount In The Green Coloured Field Under Col-6 Only. 2 Lumpsum Price Worked Out By The Contractor For “Building Or Works ” As Listed In Schedule ‘A’Part–I 3 Lumpsum Price Worked Out By The Contractor For “Internal Water Supply” As Listed In Schedule ‘A’Part–Ii 4 Lumpsum Price Worked Out By The Contractor For “Internal Electric Supply As Listed In Schedule ‘A’Part–Iii 5 Lumpsum Price Worked Out By The Contractor For “Demolition Of Buildings” As Listed In Schedule ‘A’ Part – Iv. 6 Lumpsum Price Worked Out By The Contractor For “Road / Path / Culvert As Listed In Schedule ‘A’ Part V . 7 Lumpsum Price Worked Out By The Contractor For Sewage Disposal As Listed In Schedule ‘A’ Part Vi . 8 Lumpsum Price Worked Out By The Contractor For “Area Drainage” As Listed In Schedule ‘A’ Part – Vii. 9 Lumpsum Price Worked Out By The Contractor For “Rain Water Harvesting” As Listed In Schedule ‘A’ Part – Viii. 10 Lumpsum Price Worked Out By The Contractor For “Refrigeration And Air Conditioning” As Listed In Schedule ‘A’ Part – Ix. 11 Lumpsum Price Worked Out By The Contractor For “Fire Alarm And Fire Fighting System” As Listed In Schedule ‘A’ Part – X. 12 Lumpsum Price Worked Out By The Contractor For “ Lightening Conductor” As Listed In Schedule ‘A’ Part – Xi. 13 Lumpsum Price Worked Out By The Contractor For “External Electric Supply” As Listed In Schedule ‘A’ Part – Xii. 14 Lumpsum Price Worked Out By The Contractor For “External Water Supply” As Listed In Schedule ‘A’ Part – Xiii. 15 Sch A Part - Xv : Fittings / Fixtures & Misc Items. Road / Path / Culvertm&L For Road Marking As Per Irc35 Minimum Thickness Of 1.0Mm With Hot Applied Thermo Plastic Compound With Reflectorising Glass Beads, Painting Lines, Dashes, Arrows, Letters Etc On Roads, Pavements And The Like, N.Exc 10Cm Wide, With White Or Golden Yellow Colour Including Preparing The Surface Complete All As Specified And As Directed By Engineer-In-Charge. 16 Refrigeration And Air Conditioning Supply, Install, Test And Commissioning Central Air Conditioning Installation Air Cooled Type Including Ahu, Pump Sets, Cooling Towers, Ducting And Electrical Connection Suitable For 3Phase, Ac Supply Of Capacity 120 Tr ( 3X 40 Tr ) Including Provision Of Winter Heating And Humidification Complete All As Specified And As Directed By Engineer-In-Charge. 17 Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 270 V With Built-In Thermal Overload Protection, Intitial Time Delay System, Low And High Voltage Cut-Off Protection And Of Capacity 4 Kva Complete All As Specified And As Directed By Engineer-In-Charge. 18 Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 270 V With Built-In Thermal Overload Protection, Intitial Time Delay System, Low And High Voltage Cut-Off Protection And Of Capacity 5 Kva Complete All As Specified And As Directed By Engineer-In-Charge. 19 Supply And Fix Refrigerator Electricdriven ( Single Phase, 230V, Ac, 50Hz ) Having Capacity ( Gross Volume ) Not Less Than 320 Litres, Minimum 2 Star Rated, Frost Free, Double Door, Inverter Type Compressor Complete All As Specified And As Directed By Engineer-In-Charge. 20 Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 270 V With Built-In Thermal Overload Protection, Intitial Time Delay System, Low And High Voltage Cut-Off Protection And Of Capacity 2 Kva Complete All As Specified And As Directed By Engineer-In-Charge. 21 Fire Alarm And Fire Fighting System :Providing & Fixing Testing & Commissioning Of Cubical Type Floor Mounted Fire Control Panel Fabricated From 16G M.S. Sheet Dully Painted With Stove Enamaled Finish Of Approved Shade And Comprising Of :- ( A ) One Isolation Switch. ( B ) One 63-Amp Fuse Switch Unit. With 63 Amps Hrs Fuse. ( C ) D.O.L. Starter Suitable For Main Pump Motor With Overload Relay, Single Phase Preventor, Timer, Push Buttons And Auto Manual Selector Switch 22 Providing And Applying Two Coat Of 4 Mm Thick Pypkote Antirust Protection Including Primer And Lap Of 25 Mm On100mm Dia M.S. Pipe In Trenches Or Complete Including Surface Preparation Coating And Wrapping Shall Be Confirmto Isi 10221 Including Conducting Holiday Test Complete All As Specified And As Directed By Engineer-In-Charge. ( Make :- Iwl / Stp / Tikitak ) 23 Providing & Fixing Air Release Valve Of 25 Mm Dia And 25 Mm Dia Gun Metal Gate Valve With Fittings Etc. To Be Installed At Risers Complete All As Specified And As Directed By Engineer-In-Charge. ( Make :- Kartar / Zoloto / Beer / ) 24 Supply, Installation Testing & Commissioning Of Active Repeater Panel To Be Integrated With Fire Alarm Control Panel, Larger Display Full Colour 800 X 480 Lcd With Resistive Touch Screen And Automatic Back-Light Dimming And The Status Of Any Fire / Fault Of Integrated Fire Alarm Panels, Panel Should Compliant With En54-2, En54-4 And Approved By Lpcb ( Make: Advance / Hochiki / Argus / Appollo ) . 25 Supply, Installation Testing & Commissioning Of Microprocessor Based Networkable Analogue Addressable 2 Loop Fire Alarm Control Panel. The Panel Shall Be Compliant With En54-2, En54-4 And Approved By Lpcb. The Panel Shall Have Lcd With Resistive Touch Screen And Automatic Backlight Dimming. The Panel Must Also Have The Capability To Take Addressable Intelligent Wired And Wireless Devices On Same Loop. Each Loop Shall Have A Capacity Of 127 Analogue Addressable Devices And 127 Base Sounders / Base Sounder Beacons. The Panel Shall Have An Event Log Of Minimum 1000 Events @ 1 Second Resolution, Filterable And Printable. The Panel Shall Have Three Access Levels. Panel Shall Support Upto 5000 Cause & Effects Entries, With Upto 20, 000 Inputs Controlling & 20, 000 Controlling Outputs Across The Network. The Panel Shall Have Capability For Peer To Peer Networking Through Rs485 Network Card. The Panel Must Have 4 Inbuilt Programmable Sounder Circuits, Each Circuit Rated At 2.5A.The Panel Must Have Inbuilt 3 Programmable Inputs And 5 Inbuilt Programmable Relay Outputs. The Panel Shall Have Up To Sub-Addressable 512 Programmable Inputs / Outputs Via Optional Rs485 Comms Serially Connectedexpansion Cards. The Panel Shall Have 240 V Ac Power Supply Along With Automatic Battery Charger. 26 The Panel Shall Be Fully Expandable Via Common Plug In Loop Driver Boards. The User Shall Have A Choice Of Using The Panel With 5.25 Amp Or 10.25 Amp Power Supply Unitwhich Is Inbuilt In The Facp And Should Be Approved To En54-4. The Panel Shall Have Configurable Via Usb Port To Pc Or Memory Stick. The Panel Shall Have Dedicated Rs232 Serial Port For Optional Printer. ( Make: Advance / Hochiki / Argus / Appollo ) 27 Supply, Laying, Testing And Commissioning Of Cabling For Firedetection And Alarm System With 1.5Sq.Mm 2 Core Annealed Tinned Multi Strand Copper Conductor Pvc Insulated Flexible Frls Wire In Ms Conduit As Required. ( Make :- Polycab / Havalls / Finolex / Rr Kabel / Kei ) 28 Providing And Fixing Of 16 Gauge Ms Conduit In Size 20Mm Including The Cost Of Junction Box Bends, Elbow, Sockets, Tee And Gi Flexible Conduit To Connect From Ceiling To False Ceiling Etc Laying In Slab, Cutting Chasses And Making Good Or Surfaces Mounting Including All Fixing Hardware. ( Make :- Bec Industries / Akg / Kalinga / Bharat ) 29 Providing & Fixing Of Isi Marked ( Is: 2878 ) Portable Co2 Fire Extinguisher Of Capacity 4.5 Kg Flat Base Including Valve Discharge Hose Of Not Less Than 10Mm Dia. Meter Complete In All Respect Including Initial Fill With Co2 Gas Confirming To Is 307-1966 And Filled To Filling Ratio Of Not More Than 0.367. ( Make :-Victor / Envos / Mec / Kanex ) 30 Providing & Fixing Of Isi Marked ( Is: 15683 ) Portable Afff Foam Type Fire Extinguisher, Capacity 9 Liter Complete In All Resp. ( Make :-Victor / Envos / Mec / Kanex ) 31 Providing & Fixing Of Isi Marked ( Is: 15683 ) Portable Abc Multipurpose Mono Monioum Phosphatepowder , Nitrogen Pressurised Type Fire Extinguisher, Capacity 6 Kg Complete In All Resp. ( Make :-Victor / Envos / Mec / Kanex ) 32 Providing & Fixing Of Isi Marked ( Is: 13886 ) Trolley Mounted Fire Extinguisher, Afff Mechnical Foam Type ( Gas Pressurized ) Capacity 50 Liter Complete In All Respect. ( Make :-Victor / Envos / Mec / Kanex ) 33 Providing & Fixing Of Isi Marked ( Is: 2878 ) Portable Co2 Fire Extinguisher Of Capacity 22.5 Kg Flat Base Including Valve Discharge Hose Of Not Less Than 10Mm Dia. Meter Complete In All Respect Including Initial Fill With Co2 Gas Confirming To Is 307-1966 And Filled To Filling Ratio Of Not More Than 0.367. ( Make :-Victor / Envos / Mec / Kanex ) 34 Supply, Installation, Testing And Commissioning Of 4 Kg Capacity Fm 200 , Dhp Assembly Withautomatic Valve Ce & Pie Approved, Push In Connector For Tube, Mounting Bracket, End Of Line Adopter And Low Pressure Switch For Monitoring System Activation. Make ( Rotarex / Siemens / Ceasefire / Enovs ) . 35 Supply, Installation, Testing And Commissioning Of 6 Kg Capacity Fm 200 , Dhp Assembly Withautomatic Valve Ce & Pie Approved, Push In Connector For Tube, Mounting Bracket, End Of Line Adopter And Low Pressure Switch For Monitoring System Activation. Make ( Rotarex / Siemens / Ceasefire / Enovs ) . 36 Supply, Installation, Testing And Commissioning Of 9 Kg Capacity Fm 200 , Dhp Assembly Withautomatic Valve Ce & Pie Approved, Push In Connector For Tube, Mounting Bracket, End Of Line Adopter And Low Pressure Switch For Monitoring System Activation. Make ( Rotarex / Siemens / Ceasefire / Enovs ) . 37 Supply, Installation, Testing And Commissioning Of Hooter With Accessory. Make ( Rotarex / Siemens / Ceasefire / Enovs ) . 38 Supply, Installation, Testing And Commissioning Of Ul Listed Linear Pneumatic Heat Detection Tube With All Necessary Fittings & Supports. Make ( Rotarex / Siemens / Ceasefire / Firedetec / Enovs ) . 39 Emergency Lighting Control Panel ( Approved As Per Bs En 60598-2-2 By Lia Laboratories Ltd ) With Two Lighting Lines With Maximum Of 254 Devices On Both Lines, Up To 127 Devices Per Line, Luminare Line Length 500 / 1000 Metres .The System Shall Work On Extra Low Voltage And Shall Be Addressable. Make Hochiki, Neptolux, Tamlite, Schneider, Honeywell, Ceasefire 40 Els Panel Transformer 230 V With An Output Of 35V Ac And Is Placed Between Mains And El2 Control Panel. ( Approved As Per Bs En 60598-2-2 By Lia Laboratories Ltd ) , Make Hochiki, Neptolux, Tamlite, Schneider, Honeywell, Ceasefire 41 Key Pad With An Lcd To Control, Read And Configure The Main Els Control Panel. Make Hochiki, Neptolux, Tamlite, Schneider, Honeywell, Ceasefire 42 Addressable Exit Signage Visible From 20 Mtrs ( Approved As Per Bs En 60598-2-2 By Lia Laboratories Ltd ) With Integral Battery Capacity Of 3 Hrs And Bicoloured Led Status Indicator. Available In Left, Right, Down Signs With Batteries Incorporated Into Each Luminaire Shall Be Polymer Lithium Ion Technology And Incorporate Over Voltage, Over Current And Deep Discharge Protection Circuitry.Provides At Least 3 Hours Luminaire Operation When Fully Charged. ( Approved As Per Bs En 60598-2-2 By Lia Laboratories Ltd ) , Make Hochiki, Neptolux, Tamlite, Schneider, Honeywell, Ceasefire 43 Addressable Closed Area Led Down Lighter ( Approved As Per Bs En 60598-2-2 With Bs En 60598-1:2008 +A11 By Lia Laboratories Ltd ) With Integral Battery Capacity Of 3 Hrs And Bicoloured Led Status Indicator. Make Hochiki, Neptolux, Tamlite, Schneider, Honeywell, Ceasefire 44 Addressable Open Area Led Down Lighter ( Approved As Per Bs En 60598-2-2 With Bs En 60598-1:2008 +A11 By Lia Laboratories Ltd ) With Integral Battery Capacity Of 3 Hrs And Bicoloured Led Status Indicator.Make Hochiki, Neptolux, Tamlite, Schneider, Honeywell, Ceasefire 45 Supply & Testing Of Screened And Twisted Single Pairwith 1.5Sq.Mm 2 Core Annealed Tinned Multi Strand Copper Conductor Pvc Insulated Flexible Frls Wire In Ms Conduit As Required. ( Make :- Polycab / Havalls / Finolex / Rr Kabel / Kei ) . Note : Cost Of Ms Conduit Shall Be Included In Quoted Rate. 46 Ul Listed Novec 1230 / Fm200 Pressure Fire Suppression Systemsupply, Installation, Testing & Commissioning Of 80 Litres Capacity Seamless Cylinder Ccoe Approved, Complete With Valve Assembly And Pressure Gauge With A Safety Burst Disc And A Safety Cap With Switch In Gauge Make :- Honeywell / Crypto / Rotarex / Sevo / Kidde 47 Supply, Installation, Testing & Commissioning Of Novec 1230 / Fm200 Gas Compound Of Carbon, Fluorine And Oxygen ( Cf3cf2c ( O ) Cf ( Cf3 ) 2 ) . Make :- Honeywell / Crypto / Rotarex / Sevo / Kidde / 3M 48 Supply, Installation, Testing & Commissioning Of Electric Control Head Operated Electrically From The Detection & Control System Or Locally With A Manual Lever On The Control Head.Make :- Honeywell / Crypto / Rotarex / Sevo / Kidde / Ceasefire 49 Supply, Installation, Testing & Commissioning Discharge Of Nozzles Are Designed To Provide The Proper Flow Rate And Distribution Of Fk-5-1-12 To Total Flood A Hazard Area :360 Degmake :- Honeywell / Crypto / Rotarex / Sevo / Kidde 50 Supply, Installation, Testing & Commissioning Of Master Cylinder Adapter Kit Used To Actuate The Slave Cylinder. Make :- Honeywell / Crypto / Rotarex / Sevo / Kidde 51 Supply, Installation, Testing & Commissioning Discharge Hose, 1-1 / 2” ( Make :- Honeywell / Crypto / Rotarex / Sevo / Kidde 52 Supply, Installation, Testing & Commissioning Of 1-1 / 2 Manifold Check Valve Installed At The Discharge Manifold To Allow Removal Of Any Fk-5-1-12 Cylinder From The Manifold While Still Retaining A Closed System.Make :- Honeywell / Crypto / Rotarex / Sevo / Kidde 53 Supply, Installation, Testing & Commissioning Of Supervisory Switch For Indication Of Discharge Of System. 54 Supply, Installation, & Fixing Of Of Cylinder Strap For 80 Ltr. Cylinder. 55 Supply, Installation, Testing & Commissioning Of Brass Male Elbow. 56 Supply, Installation, Testing & Commissioning Of M.S.Seamless Schedule 40 Pipe Up To 50 Mm Dia Size Including Allforged Fittings Such As Tee, Elbow, Supports And Paitning As Per Requirement Of Site, Etc.Pipe ( S ) : M.S. Seamless To Astm A-106, Sch. 40 57 Supply, Installation, Testing And Commissioning Of 2 Zone Gas Release Panel With Release Module And Battery Backup. Make ( Kidde / Hochiki / Siemens / Ravel / Ceasefire / Honeywell ) . 58 Supply, Installation, Testing And Commissioning Of Manual Release Switch. Make ( Kidde / Hochiki / Siemens / Ravel / Ceasefire / Honeywell ) . 59 Supply, Installation, Testing And Commissioning Of Abort Switch. Make ( Kidde / Hochiki / Siemens / Feuerx / Ravel / Ceasefire / Honeywell ) . 60 Supply, Installation, Testing And Commissioning Of Convensional Smoke Detector. ( Make: Advance / Hochiki / Argus / Appollo / Ravel / Ceasefire / Honeywell ) 61 Supply, Installation, Testing And Commissioning Of Convensional Manual Call Point. ( Make: Advance / Hochiki / Argus / Appollo / Ravel / Ceasefire / Honeywell ) 62 Supply, Installation, Testing And Commissioning Of Convensional Hooter. ( Make: Advance / Hochiki / Argus / Appollo / Ravel / Ceasefire / Honeywell ) 63 Supply, Laying, Testing And Commissioning Of Cabling For Firedetection And Alarm System With 1.5 Sqmm 2 Core Annealed Tinned Multi Strand Copper Conductor Pvc Insulated Flexible Frls Wire In Ms Conduit As Required. ( Make :- Polycab / Havalls / Finolex / Rr Kabel / Kei ) Note : Cost Of Ms Conduit Shall Be Included In Quoted Rate. 64 S&F Recessed Mounted Accent Lighting Luminaire 42W Suitable For 230V Ac 50Hz Supply With Diecast Aluminum Heat Sink And Sand Grain Finishing Reflector, With 2.5 Kv Surge Protection, Angle Of Light Beam Spread-24 Degree, Available In Two Lumen Packs With Option Of Dali Dimmable Driver. Type , Make - Phillips Cat Part No - Rs -271B Led 40 / 840Or Its Equivalent To Bajaj / Havells / Wipro 65 S&F Lux Space Pro Is A Deep Recessed Downlighter 18W Range Suitable For 230V Ac 50Hz Supply With Extremely Low Glare ( Ugr <19 ) & High Quality Faceted Reflector For Superior Lighting And Aesthetics. The Range Is Available In Medium ( 32° ) & Wide Beam ( 65° ) Optics For Both Standard And High Ceiling Applications. Make:Phillps Cat Part No Dn590b M Led20s 66 S&F Sit Rowindicator And Foot Light10watt , Suitable For 230V Ac 50Hz Supply Withmarking And Direction 67 S&F Excess Electronic Controlsystem 68 S&F Led Light 18Watt Dimmable Type Suitable For 230V Ac 50Hz Supply Cat Part No Dn195 Make Phillipsor Equivalentto Bajajhavells Or Wipro ( For Motivation Hall 12 Nos ) 69 S&F Decorativeroof Lightat Reception Roomof Diamonds Are Forever Gold Crystal Chandeliercomplete Suitable For 230V Ac 50Hz Supply . 70 S&Fip65, Dust And Waterproof Led Luminaire 36W Suitable For 230V Ac 50Hz Supply With Polycarbonate Housing Suitable For Wall & Ceiling Mount Applications. Type Make -Phillips Cat Part No -Wt201cled-445 / 6500Psuor Its Equvilant To Bajaj / Wipro 71 S&F Led Light 2X2 42W Suitable For 230V Ac 50Hz Supply Decorative Type Cat Part No Rc740bled 36Ws ( 2X2 ) Make Phllips Or Equivalent To Bajaj , Wipro 72 S&F High Performance Led Downlights Suitable For 230V Ac 50Hz Supply100 Lumen / Watt Efficacy , Efficient Heat Sink ( Die Cast ) With Steel Clips, Integrated Driver Control ( For Easy Installation ) Type Hsn, 16 Watt Cat Part No Dn 194B-Led20s-365 / 865 W60l60 Make Phillips Or Its Equvilant To Bajaj / Havells / Wipro 73 S&F Electrically Operated Chimney Single Phase 230 Volt For Modular Kitchen, Faber 90Cm 1200Mcub / Hr Heat Auto Clean Chimney Suitable For Kitchen Of Size 8100Mm X 5000Mm And Height 3500Mm 74 S&F Telehpone Socket Special Type ( For Telephone / Data Cable ) 75 S&F Tv Socket Special Modular Fiush Type 76 S&Fgarden Led Bollard Light 10Wcat Part No-Lblsr-10-Ww Make -Crompton 77 S&Fgarden / Pathway Ledpost Toplight 20Wcat Part No-Lpth 20-Ww- Make 7 / 6 / 2021Crompton 78 S&F Junction Box Of Minimum Size 100Mmx100mmx75mm Consisting Of 4 Way Connector, Insulators Etc Suitable For Post Top Light With Fixing Clampsall As Specified And As Directed. 79 External Electric Supply : Supply & Fix Cubical Type, Factory Made Lt Panel Board, Suitable For 3 Phase, 415 Volts, 50 Hz System, With Aluminium Bus Bar For R, Y, B And Neutral And Bus Bar Size Shall Be Suitable To Carry Current At 1.5 Times Current Carrying Capacity Of Out Going Switch Gears, , Outdoor Type, Factory Fabricated With 3.15 Mm Thick Crca Sheet With Inspection Doors At Front & Rear Side Inclusive Of Necessary Locking Arrangement, Suitable Glands, Opening For Vent And Cable Entry, Spare Terminal For Mccb With Angle Iron Of Size 50X50x5 Mm Thick, Grouted In Floor Complete With The Following Accessories, Duly Pre-Treated And Powder Coated Finish Complete. ( A ) Mccb, 4 Pole 500A, 50 Ka- 01 No ( Incoming ) . ( B ) Mccb, 4 Pole 320A, 50Ka- 01 No ( To Ac Plant ) . ( C ) Mccb, 4 Pole 250A, 50Ka- 01 No ( To Briefing Hall ) . ( D ) Mccb, 4 Pole 160A, 50Ka- 01 No ( To Apfc ) . ( E ) Mccb, 4 Pole 160A, 50Ka- 01 No ( Spare ) . ( F ) Spare Box / Space For Fixing Mccb 01 No ( Mccb Not To Be Provided ) . ( G ) Digital Display Vaf Panel Meter- 01 No With Ct Coils. ( H ) Led Indicator Ryb - 01 Set. ( J ) Sufficient Space Shall Be Provided Within Lt Panel For Installation Of 4 Kg Fire Extinguisher ( Cost Of Fire Extinguisher Is Not Included ) . 80 Supply & Fix Cubical Type, Factory Made Lt Panel Board, Suitable For 3 Phase, 415 Volts, 50 Hz System, With Aluminium Bus Bar For R, Y, B And Neutral And Bus Bar Size Shall Be Suitable To Carry Current At 1.5 Times Current Carrying Capacity Of Out Going Switch Gears, , Indoor Type, Factory Fabricated With 2 Mm Thick Crca Sheet With Inspection Doors At Front & Rear Side Inclusive Of Necessary Locking Arrangement, Suitable Glands, Opening For Vent And Cable Entry, Spare Terminal For Mccb With Angle Iron Of Size 40X40x5 Mm Thick, Grouted In Floor Complete With The Following Accessories, Duly Pre-Treated And Powder Coated Finish Complete ( A ) Mccb, 4 Pole 250A, 35 Ka- 01 No ( Incoming ) . ( B ) Mccb, 3 Pole 125A, 35Ka- 01 No. ( C ) Mccb, 3 Pole 100A, 35Ka- 02 No. ( D ) Mccb, 3 Pole 63A, 35Ka- 02 No. ( E ) Spare Box / Space For Fixing Mccb 01 Nos ( Mccb Not To Be Provided ) . ( F ) Digital Display Vaf Panel Meter- 01 No With Ct Coils. ( G ) Led Indicator Ryb - 01 Set. ( H ) Sufficient Space Shall Be Provided Within Lt Panel For Installation Of 4 Kg Fire Extinguisher ( Cost Of Fire Extinguisher Is Not Included ) 81 Supply, Installation, Testing And Commissioning Of Diesel Engine Driven Generating Set Alongwith Acoustic Enclosure 415V, Ac, 3 Phase 4 Wire 50Hz Having Capacity 320Kva Including Pcc Platform As Recommended By The Manufacturer Automatic On Mains Failure ( Amf ) Type 0.8 Power Factor 50 Hz 1500 Rpm Self Excited, Self Regulate Brushless Ac Generator Suitable For Ambient Conditions Complete With Relay Panel, For Automatic Starting On Main Failure Control Panel And Confirming To Is With The Following For Dg Set Complete With Acoustic Enclosure. 82 ( A ) Alternator :Standard Design Alternator Rated At 320 Kva Net Output At Site After Considering De-Rating As Per Site Conditions At Power Factor 0.8, Ac 3, Phase 4 Wire, 415 Volts, 50 Cycles, 1500 Rpm Self Excited Self Regulated Screen Protected Drip Proof Ip 23 Brushless Design With Hub And Shield / Roller Bearing With Winding In Each Face Insulating Class H Band Of Voltage Regulation ± 5% Of Rated Voltage From No Load To Full Load The Alternator Shall Be In Position To Generate Supply With Frequency / Regulation Within ± 1% Tolerance. 83 ( B ) Diesel Engine Adequate Capacity Diesel Engine ( Not Less Than 400Hp ) Water Cooled To Drive Independently Above Alternator And After Considering De-Rating As Per Site Conditions Generating And Reducing Power Consumed By Accessories. Directly Coupled Through Flexible Coupling , Multi Stroke Direct Injection, Cold Starting 1500 Rpm As Per With On Overload Capacity Of 10% One Hour In A Day 12 Hours Continuous Running Complete With Standard Accessories All As Specified And Required For Safe Handling And Operations. ( B1 ) Retrofit Emission Control Device ( Recd ) Suitable Capacity Recd Shall Be Supplied, Fixed, Commissioned And Tested By Contractor Alongwith All Required Items For Its Satisfactory Working. This Device Should Control Dg Set Emissions Such As Oxides Of Nitrogen, Hydrocarbon, Carbon Monoxide, Particulate Matter And Smoke Within Limits As Prescribed By Cpcb. Necessary Testing Arrangement Shall Be Provided By Contractor At His Own Cost. 84 ( C ) Control Panel ( Controller ) It Shall Be Microprocessor Based, Integrated With Amf Panel, Graphical Lcd Display.Monitoring Features:- Phase Voltages & Currents, Frequency, Reverse Power, Genset Kva, Kw, Kwh, Kvar, Power Factor, Canopy Temperature, Lube Oil Pressure, Engine Temperature, Rpm, Run Hours, Number Of Starts, Fuel Level, Auto / Manual Stop, Battery Charge Condition.Diagnostic Features:-Battery Charging Failure, Over / Under Speed, Over Current , Over / Under Voltage, Over Kw, Phase Seq., Phase Missing, Mains Under Voltage, Earth Fault Trip, Fuel Usage Alarm, Low Lube Oil Pressure, High E N G I N E Te M P E R A T U R E , Low / High Battery Voltage, Low Fuel Level, Over Crank Protection , Routine Maintenance Indicator, Gen Set Test Facility, Mains Frequency. 85 ( D ) Accoustic Enclosure Noise Level Less Than 75Dba, Ease Of Access And Serviceability, Aesthetically Designed, Weather And Sound Resistant Enclosure, Insulation Conforms To Ul94-Hf1 Class For Flammability, Shall Be Provided With Anti Vibration Pads 86 ( E ) Amf Panel :- Amf ( Auto On Mains Failure ) Panel, Kiosk Type Outdoor, Weather And Vermin Proof Factory Made Cubicle Made Out Of Crca Sheet 3.15Mm Thick Front And Rear Opening Of 415 Volts, 3 Phase 4 Wire Ac 50 Cycles Having Bus Bar Capacity Suitable To Carry Current Of 110% Full Load 320 Kva Dg Set Generation Complete With Following Items:- Mccb Tp 500A, 50Ka Qty-02 Nos, Contactor 500A, 3P Qty-02 Nos, Aluminium Bus Bars ( R, Y, B, N ) Of Suitable Rating, Relay, Amf Logic Controller, Battery Charger, Single Phase Preventor, Auto / Manual Switch, Start, Stop Push Button, Volt Meter, Ammeter, Kwh Meter, Ryb Indicators, Load On Dg Indiacator, Load On Mains Indicator, Protection Gears Etc. Any Item Other Than Above But Required For Automatic Operation, Protection Of Life And Components Shall Be Provided By Contractor Without Additional Cost. 87 Amf Functioning Starting The Dg Set When There Is A Failure Of Main Supply / Single Phasing Or When The Voltage Is Lower / Higher Than The Pre Set Value Or Where There Is Failure Of One / Two Phases. Transferring The Load To The Dg Set From The Mains. Transferring The Load Back To The Mains When Healthy Mains Supply Is Restored And Stoppage Of Dg Set. Note : The Above Functions Shall Be Carried Out Automatically Without Human Intervention. 88 ( F ) Civil Works All Civil Works Related To Foundation Installation Of Panel And Equipments Including Making Good Of Existing Structure If Disturbed During Installation And Commissioning Of Gen Set, ( Total Depth Of Foundation Shall Be Minimum 300Mm With Anti Vibration Pads ) . 89 ( G ) Testing ( I ) Necessary Testing Equipment And Heater Load For Testing Before Handing Over The Work ( Phase -I & Phase -Ii Tests ) Shall Be Carried Out By The Contractor To The Entire Satisfaction Of The Accepting Officer Or Any Person Authorized By Him And The Satisfactory Results Shall Be Kept In Mes Records Duly Signed By The Contractor, Engineer-In-Charge And Testing Officer. ( Ii ) Phase -I Test Will Be Performed For 1 Hour Without Load After Completion Of Installation By Engineer-In-Charge. ( Iii ) Phase-Ii Test Will Be Performed For 12 Hours By The Rep Of Accepting Officer. ( Iv ) Dhpp ( Diesel ) Required For Phase-I And Phase-Ii Testing Shall Be Supplied By Contractor On His Own Cost. 90 External Water Supply : Material & Labour For Cutting Of Existing Bituminous Road / Hard Standing Upto 15Cm Depth For Laying Of Pipe & Making Good To The Disturbed Surfaces By Providing Pcc Or Same Material After Laying Of Pipe And Returning Filling Of Soilcomplete All As Specified And As Directed. Note:- Excavation And Earth Work Will Be Measured And Paid Under Relevant Items. 91 Construction Of Valve Chamber Having Inner Dimension 600 X 600 X 600 Mm ( Suitable For Gate Valve Upto 50Mm ) With Pcc 1:4:8 Type D2 For Foundation, Brick Work Wall In Cement Mortar ( 1:4 ) , Pcc 1:2:4 Type B1 For Coping, Rendering Plaster In Cm 1:4, 15 Mm Thick Including Provision Of Ms Sheet Top Cover 3 Mm Thick With Brazing Of Ms Flat Of Size 25 Mm X 4 Mm At Edges And In Diagonal And Angle Iron Base Frame Of 40 X 40 X 5 Mm, Painting With Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer On Iron Surfaces, Lime Wash On Internal And External Cement Surfaces And Locking Arrangements Necessary Excavation Earth Work Complete All As Specified And As Directed. 92 Cutting Existing Iron Pipe In Position And Inserting New Gi Tee Of 50X50x50 Mm Dimension Complete All As Specified And As Directed.Note:- Excavation And Earth Work Will Be Measured And Paid Under Relevant Items. 93 Internal Water Supply :Supply And Fix 15Mm Bore 2 Way Bib Tap Brass Chromium Plated Fancy Type With Wall Flange Complete All As Specified And As Directed. 94 Internal Electric Supply :Supply And Fix Vertical Tpn Distrubtion Board Ip43 6Way Suitable For Mccb Triple Pole As Incommer Complete All As Specified And As Directed. Note:- Incomming Mccb And Outgoing McbS Will Be Measured And Paid Separately. 95 Supply And Fixmcb Single Pole C Curve 6-32 Amps 10Ka Complete All As Specified And As Directed. 96 Supply And Fixmcb Triple Pole C Curve 63 Amps 10Ka Complete All As Specified And As Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Mar-2024 Amendment No 1 Date 01-04-2024
2 21-Mar-2024 Amendment No 2 Date 11-04-2024
3 04-Apr-2024 Amendment No 3 Date 22-04-2024
4 10-Apr-2024 Amendment No 4 Date 02-05-2024
5 19-Apr-2024 Amendment No 5 Date 07-05-2024
6 25-Apr-2024 Amendment No 6 Date 14-05-2024

Key Value

Document Fees
INR 3000 /-
EMD
INR 745350.0 /-
Tender Value
INR 8.40 Crore /-

Attachment

FileName File Description File Size
c2aaa331-7aa0-423d-bb5b-b3fdcd41760a.html Tender Notice 0 KB
801536TENDER.pdf Tender Document 0 KB
ArchDrawings.pdf Tender Document 0 KB
BOQ_718099.xls Tender Document 0 KB
Strldrawings.pdf Tender Document 0 KB
TDDWG.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail