Tender For Manning And Operation, Repairs And Routine Maint Of Central Ac Plant And Cold Storage Installation At Nad, Mwc, Ccdt, Cg Complex And Ins Vajarbahu And Others Loc Etc Under Ge (Nw) Kunjali, Colaba, Mumbai, kunjali-Maharashtra

Military Engineer Services-MES has published Tender For Manning And Operation, Repairs And Routine Maint Of Central Ac Plant And Cold Storage Installation At Nad, Mwc, Ccdt, Cg Complex And Ins Vajarbahu And Others Loc Etc Under Ge (Nw) Kunjali, Colaba, Mumbai. Submission Date for this Tender is 13-03-2024. HVAC Tenders in kunjali Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42118771
Corrigendum : Tender For Manning And Operation, Repairs And Routine Maint Of Central Ac Plant And Cold Storage Installation At Nad, Mwc, Ccdt, Cg Complex And Ins Vajarbahu And Others Loc Etc Under Ge (Nw) Kunjali, Colaba, Mumbai
Open Tender
Indian
Maharashtra
kunjali
13-03-2024

Tender Details

Manning And Operation, Repairs And Routine Maint Of Central Ac Plant And Cold Storage Installation At Nad, Mwc, Ccdt, Cg Complex And Ins Vajarbahu And Others Loc Etc Under Ge ( Nw ) Kunjali, Colaba, Mumbai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-03-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 132250.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : MANNING AND OPERATION, REPAIRS AND ROUTINE MAINT OF CENTRAL AC PLANT AND COLD STORAGE INSTALLATION AT NAD, MWC, CCDT, CG COMPLEX AND INS VAJARBAHU AND OTHERS LOCETC UNDER GE (NW) KUNJALI, COLABA, MUMBAI
Sl. No. Item Description
1Manning & operation for following Central AC Plants TPW and NAD run in two shift per day (shift 08 hrs) by Ref Mech (Semi Skilled) including maintaining record periodical minor maint/ repairs (ie daily check, monthly, quarterly and half yearly) with all consumable parts except for major repair and spare parts of central AC plants at TPW, NAD A-63 Building Naval Dockyardincluding daily cleaning of AC plants complete with cooling tower AHU & other accessories for 08 hours run daily in two shift including Sunday and Holidays from 0800 hrs to 1600 hrs. to 1600 hrs to 2400 hrs
2NAD AC PLANT :- 02 Nos x 40 TR, Make :- Voltas Model No ACC WC04000 MNT(a)Compressor Make Voltas Model No ACC WC04000 MNT -02 Nos. (b) Compressor motor 60HP-02Nos. (c) Condenser/ chiller water pump set mono block-04Nos. (d) Air handling unit with blower motor -01No. (e) FRP Cooling tower with CT Fan- 01No. (f) Electrical control panelcubical type floor mounted with main switch MCB"s voltmeter, Ammeter, Starter condenser etc. complete-01 Set. (g) Control devices such as expansion valvethermostat solenoidvalves HP/ LP/ CPcut outs with panel, panel board installed gauges-01Set (h) Digital type thermometer-01Set (j) Air supply duct with grill diffusers dampersand re-heater, pre-heaters etc. complete-01Set (k)Condensers and Condenser piping, Chilled water piping lines 100/80/50mm with valves, water pressure gauge and water temperature gauge complete-01Set
3Manning and Operation for package type AC plant by Ref Mech (Semi Skilled) of capacity 06 Nos x 11 TR,Make :- Blue staratVAJARABAHU ND running daily round the clock (24 hrs) in 3 shifts ie (06.00 hrs to 14.00 hrs, 14.00 hrs to 22.00 hrs and 22.00 hrs to 06.00 hrs) for smooth functioning of entiresystem and to maintain specific temperatureincluding daily cleaning area of AC plant complete including Sunday & Holidays.
4Manning & operation of Central AC Plants in one shift per day (shift 08 hrs) operated by one Refg Mech (Semi Skilled) including maintaining record periodical minor maint/ repairs (ie daily check, monthly, quarterly and half yearly) with all consumable parts except major repair and spare parts of central AC plant CCDT (B) Naval Dockyard complete of 02 Nos x 7.5 TR capacity (Make : KirloskarModel AK- 3) with cooling tower AHU and other accessories (one running and one standby) for single shift of 08 hrs daily from 0900hrs to 1700hrs including Sundays & Holidays including maintain cleaness of AC plant Complete all as specified and directed by Engineer- in-charge.
5Manning & operation of Central AC Plant in one shifts per day (each shift 08 hrs) operated by one Refg Mech (Semi Skilled) in one shift including maintaining record periodical minor maint/ repairs (ie daily check, monthly, quarterly and half yearly) with all consumable parts except major repair and spare parts of central AC plants condensing unit complete of 3 Nos. x 40 Ton (two running & one standby ) (Make :- Voltas, Model No. ACWCURO0400MNT at MWC building No.173 (ND)including maintain cleaness of AC plantcomplete with cooling tower AHU & other accessories run for one shifts daily from (09.00 hrs to 17.00 hrs) including Sundays & Holidays Complete all as specified and directed by Engineer- in-charge.
6Manning and Operation of Walk in Cooler (Mutton Point CG Complex Make :- Blue star) running round the clock in (three shifts) by Ref Mech (Semi Skilled) each shift of 08 hour ( 06.00 hrs to 14.00 hrs, 14.00 hrs to 22.00 hrs and 22.00 hrs to 06.00 hrs) dailyincluding Sundays and Holidays including maintaining cleaness of AC plant of the following plants :- (a) 03 Nos cabinet/ rooms of Walk in cooler consisting total 09 Nos refrigeraion unitshaving capacity of each unit 2 TR driven single phase, Emerson hermetically sealed compressor units model CR-1010 BCU10 ( 02 running & one standby in each walk in cooler room) for maintain the temperature range 08° C to 12°C RH 60% for eggs room. Make: Blue Star (b) 02 Nos Walk in cooler having refrigerant unit 06 Nos x 10TR each three phase hermetically sealed compressor Model LC-2120 (02 Nos running and one stand by in each walk- in- cooler) for maintaining the temperature range (-) 18°C to (-) 20°C RH 50% for fish/ mutton/ chicken room
7Notes for item No 1.0 to 5.0- (i) Contractor shall submit ID proof, residential proof, bank A/C details to department and obtain approval of Engineer-in-Charge before employing a person as Ref Mech (ii)Ref/ AC mechanic shall be available as per the shift timings specified in the tender and he will report to JE E/M in-Charge. In case of emergency he will function according to their direction.If he is found absent or move without intimating to in-Charge or JE he will be treated as absent for the said shift and recovery of Rs 1500/-per shift shall be affected. (iii) Payment as per quoted rate shall also be deducted in addition to the penalty as specified above. (iv) Contractor shall submit the labour licence & Copy of GST Regn registered number issued by concerned authority. (v)The payment shall be made to employees on or before 10th of every calender month.Payment to employees shall be done by crossed cheque / RTGS / NEFT / IMPS through Aadhar card linked Bank Account only and it shall not be less than minumum fair wages and statutory requiments such EPF and ESI as per Act in vogue. (vi)The rate quoted by the contractor shall be inclusive of life insurance for the tradesmen employed by him in case of untoward incident such as injuries fracture or casualty while on duty (vii) Surprise check will be carried out by department representative and if any employes is not available at his working place, he will be treated as absent. (viii)Contractor has to submit the list of employees including reserve alongwith police verification, Aadhar card, Aadhar card linked Bank Account No and relevant documents as mentioned in PS to the Engineer-in-Charge alongwith performance security before issue work order.
8(ix)Contractor has to submit proof of payment of EPF and ESI subscription made by his alongwith RAR failing which RAR will not be progressed for payment (x)Contractor has to employ the number of labours per day as intimated by the Engineer-in-Charge for which he has to make alternative arrangement. (xi) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (xii)Contractor shall quote the rates considering their monthly leaves, releiver etc as per labour laws and nothing extra shall be paid on account of the above. In case of absence of staff/tradesman from duty, payment of that day will not be paid. In addition to that a penalty of Rs 1500/- per day per person will be recovered from contractors dues.Also in case of long absence (more than one week) of staff/tradesman, the penalty shall be recovered including Sundays & Holidays if any.The contractor shall have no claim on this account. (xiii) Contractor has to supply two sets of Tools and Plants (as applicable) to the labours employed by him and should be placed with the safe custody of department.Rates quoted shall be deemedshall be included as part of contractors profit.
9(xiv)The bidders shall not quote rate less than minimum fair wages including other statutory requirement such EPF and ESI including GST as given at para 19 of Sch A Notes. If the quoted amount is less than the estimated cost, the lowest bidder will have to deposit FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid.(xv)The deposited amount shall be the difference between estimated costand amount quoted by lowest bidder for respective item. FDR/BGB shall be released only after satisfactory completion of work.If the contractor fails to pay minimum wages to employees and other statutory requirments like EPF and ESI, the department shall have right to withhold the said amount which will be verified and confirmed by GE.The decision of Accepting Officer regarding amount to be withhold shall be final and binding.The withhold amount will be utilised byGE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 working days, it shall be treated as willful negligence of the bidder with ulterior motives and such tenderer shall be banned from bidding for a period of six months commencing from the date of opening of Financial Bid .The contractor shall sumbit 03 Nos of BGBs/FDRs of equal amount as mentioned above.The BGBs/FDRs validity shall be 04months, 08 month & 12 monthsrespectively for the purpose of encashment/ release as the case may be. (xvi) The rates quoted shall be inclusive of suitable reliver wherever sundays & holidays are mentioned for working (xvii) Quoted rates should include Stationary,Uniform,Shoes,log book and all safety equipments/ Harness which shall be included as part of contractors profit.
10Labour only for repair/overhauling and including replacement of unserviceable spares of AC Plantcompressor reciprocatingtype model5 H 40 OF VOLTAGE Make by dismantling complete assembly, after pumping down refrigerant R-22, checking of all spares and segregate of serviceable and unserviceable spares overhaulingthe compressor includingreplacement of unserviceable spares, alsoincluding machining of crank shaft bearing,polishing, replacing of gasketspacking,reassembling complete and rechargingof pumpeddown Refrigerant, also charging of additional refrigerant upto the required pressure & topping up if required to maintain the required standingcharged pressure of compressor oil and gas, testing for smooth functioning etc,Complete all as specified and directed by Engineer- in-charge. Location :MWC AC PLANTS (Note: Cost of all the elements (material cost as well as labour cost) for making the compressors completely functional except the following shall be deemed to be included in the quoted rates : (a) Supply only spares for compressor reciprocating type model 5 H 40 of existing Make included under item Nos 06.01 to 06.17 here-in-after. (b) Supply only additonal refrigerant required for recharging of pumped down refrigerant, if required and paid under relevent item here-in-after. (c) Supply only compressor oil for topping up, if required and paid under relevent item here-in-after.
11Crank shaft
12Piston
13Oilrings
14Shaft seal assembly
15Liner assembly
16Oil pump assembly
17Rockers arm
18Loader/unloader spring
19Piston rings
20Suction valve reeds
21Discharge valve reeds
22Oil filter
23Suction strainer
24Oil pressure regulating valve
25Connecting rod
26Gasket set
27Compressor safety valve
28Labour only for repair/overhauling and including replacement of unserviceable spares of AC Plantcompressor reciprocatingtype model5 H 60 OF VOLTAGE Make by dismantling complete assembly, after pumping down refrigerant R-22, checking of all spares and segregate of serviceable and unserviceable spares overhaulingthe compressor includingreplacement of unserviceable spares, alsoincluding machining of crank shaft bearing,polishing, replacing of gasketspacking,reassembling complete and rechargingof pumpeddown Refrigerant, also charging of additional refrigerant upto the required pressure & topping up if required to maintain the required standingcharged pressure of compressor oil and gas, testing for smooth functioning etc, Complete all as specified and directed by Engineer- in-charge. Location :NAD AC PLANTS (Note: Cost of all the elements (material cost as well as labour cost) for making the compressors completely functional except the following shall be deemed to be included in the quoted rates : (a) Supply only spares for compressor reciprocating type model 5 H 40 , Make : VOLTAGEincluded under item Nos 7.01 to 7.17 here-in-after. (b) Supply only additonal refrigerant required for recharging of pumped down refrigerant, if required and paid under relevent item here-in-after. (c) Supply only compressor oil for topping up, if required and paid under relevent item here-in-after.
29Crank shaft
30Piston
31Oilrings
32Shaft seal assembly
33Liner assembly
34Oil pump assembly
35Rockers arm
36Loader/unloader spring
37Piston rings
38Suction valve reeds
39Discharge valve reeds
40Oil filter
41Suction strainer
42Oil pressure regulating valve
43Connecting rod
44Gasket set
45Compressor safety valve
46Pumping down the compressor and transfer existing refrigerent gas complete for overhauling of compressor reciprocating open type model FK - 4 Kirloskar Make 2 x 7.5 TR Capacity, dismantling complete assembly & replacing of minor unserviceable parts including machining of crank shaft boring polishing etc replacing of gaskets packing reassembly and recharging ofpumped down refrigerant & topping up if required to maintain the required standing pressure charging of compressor oil complete testing for smooth functioning etc.at CCDT ND complete all as specified and directed by Engineer- in-charge. (Note : Major spare parts, compressor oiland refrigerant gas for topping up will be paid separately )
47Material and labour for cleaning of cooling coil section of AHUfor descaling and providing 02 Nos.15mm Tee outlet for local circulation of MAIC solution in the cooling coil (separate container and pump set of appropriate capacity to be used for circulation) pH value of solution to be kept at 4 & checked at an interval of 01 hr. duration process the scalgum / WS / Cleansol or equivalent solution to be used for descaling if ph value remains less than "7" flush with fresh water addedto sodium carbonate till pH value attains "7" refix the coilsection in position minor repairs to be carried out in AHU Coil bins to be cleaned by scalgum solution by spraying the solution with washing pump up to required level, AHU and Complete all as specified and directed by Engineer- in-charge for the followings :-
48AHU of2 x 50TR Capacity AC Plant at NAD A-63 Naval Dockyard
49Dismantling AHU of 2 x 60TR TR capacity AC plant carefully by removing side and top panel removing unserviceable blower shaft bearings,removing motor & blower assembly, replacement of new AHU blower shaft bearings reassembling blower assembly and refixing electric motor & top side panel in original position with new nut bolts washers & shafts keys & checking the shafts balancing & testing for smooth running complete all as specified and directed by Engineer- in-charge. at NAD A-63 Naval Dockyard.
50All as per item No 11.00 but for 2 x 7.5 TR AC Plant at CCDT(ND)
51All as per item No 11.00 but for 3x 40TR AC Plant at MWC Bldg No 173(ND)
52Material and labour for dismantling cooling tower by removing CT Fans, sprinklers, PVC filler and clean cooling tower body by removingscale , dust, dirt and refix PVC filler by cleaningwith dilutedHCL solution reassembling, connecting , cleaning externalsurface and applying two coats of approved synthetic enamel paint including writing SM number/ markingand testing etc Complete all as specified and directed by Engineer- in-charge for the following capacity cooling towers for the following :-
53Cooling towerof 2 x 50 TR Capacity at NAD A-63 Naval Dockyard
54Cooling towerof 6 x 7.5 TR Capacity at A - 14 (Naval Dockyard)
55Cooling towerof 3 x 40 TR Capacity at MWC Bldg. No. 173.(Naval Dockyard)
56Supply and fixing in repair of unserviceable / worn-out "V" Belt of AHU"s complete all as specified and directed by Engineer- in-charge.
57Supply and fixing in repair of unserviceable / worn-out rubber coupling suitable for compressor shaft and motor shaft Complete all as specified and directed by Engineer- in-charge.
58Takingout old unserviceablecooling tower fills sheets of 2X50 TR from the siteand supply and fix new fibre fills sheet of same size for coolingtower as per the existing at site and complete all as specified and directed by Engineer- in-charge at NAD A-63 Naval Dockyard
59Taking out old unserviceable cooling tower nozzles and supply and fix new cooling tower nozzles suitable for 2x 60 TRMihir make cooling toweras per existingat NAD A-63 Naval Dockyard complete all as specified and directed by Engineer- in-charge
60Material and labour for disconnecting condenser for descaling & plugging them & providing of 15 mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) pH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be usedfor descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7 flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulatingdiluted acid solution as specified above & pH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for the following :-
61Condenser of2 x 50TR Capacity AC Plant at NAD A-63 Naval Dockyard
62Condenser of 2 x 7.5 TR Capacity AC Plant at CCDT (ND)
63Condenser of 3 x 40TR Capacity AC Plant at MWC Bldg. No.173(ND)
64Material and labour for disconnectingfor Chiller descaling & Plugging them & providing of 15 mm tee outlet for local circulation of mild acid solution in the Chiller (separate container and small pump set to circulate diluted acid solution to be used) pH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be usedfor descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7, flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulatingdiluted acid solution as specified above & pH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for the following :-
65Chiller of2 x 50TR Capacity AC Plant at NAD A-63 Naval Dockyard
66Pumping down theexisting refrigerant fromthe condensor and carrying out theleak test of plant with the pressure of Nitrogen gasand monoitoring for 24hrsassesleakages by brazing & replacementof necessary gasketwhereverrequired including copper tubes of suitable size vacumizing of the plant by vaccum pump finallyreharging of existing refrigerant gas to the plant and topping up of refrigerant if requiredtomaintain the standard pressure etccomplete including testing of the plant for smooth functioning Complete all as specified and directed by Engineer- in-charge. (Note: Refrigerant required for topping up will be measured and paid separately under relevant items)
67Rewinding ofunserviceable electric motor 3 phase 50 Hz 415volt offollowing capacity pump set complete comprising as under :- (a) Disconnecting& removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wireofexisting gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. completefor class "F" insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc Complete all as specified and directed by Engineer- in-charge. NOTE: Any damage caused during handling will be made good by contractor without any extracost to department
687.5 HP Chiller / Condenser Water Pump Motor .
6915 HP Chiller/CondenserWater Pump Motor.
705.0 HP Chiller/CondenserWater Pump Motor.
713.0 HP Chiller/CondenserWater Pump Motor.
7210 HP Condenser/Chiller Water Pump Motor.
7315 HP Compressor Motor .
7460 HP Compressor Motor.
7540 HPMotor.
7650 HP Motor.
7725 HP Motor.
78Overhauling of Monoblock pump set after removing from the base plate, disconnectingfrom pipe line, dismantling the pump set, replacing unserviceable gland packing, gun metal bush bearing water seal applying grease etc. complete and reassembling the pump set connecting with pipe line reconnection of electric supply, including buts bolts, gaskets etc. complete testing of pumps for smooth functioning with following capacityof pumps and motors complete all as specified and directed by Engineer- in-charge:-
797.5 HP Chiller / Condenser Water Pump
8015 HP Chiller/CondenserWater Pump
815.0 HP Chiller/CondenserWater Pump
8210 HP Condenser/Chiller Water Pump
83Over hauling sevicing of electric motor after removing from the base foundation including disconnecting of electric connection and replacment of unserviceable ball bearing complete and reassembling, realignment and reconnection of electric supply complete and testing on load for smooth functioning of following capacity motors complete all as specified and directed by Engineer- in-charge:-
8415 HP Motor .
8560 HP Motor.
8640 HP Motor.
8750 HP Motor.
8825 HP Motor.
8910 HP Motor
90Supply and charging refrigerant R-22 gas in AC plant system as per requirement complete all as specified and directed by Engineer- in-charge
91Supply only refrigerant R-407(a) gas as per requirement, Complete all as specified and directed by Engineer- in-charge.
92Replacement of compressor oil with new compressor oil Complete all as specified and directed by Engineer- in-charge.
93Material and labour for repairs to Microprocessor of 50/60 TR Capacitychiller unit including replacing diods , transistors and wiring etc for AC Plant at NAD A-63 Naval Dockyardall Complete all as specified and directed by Engineer- in-charge.
94Material and labour for Expansion valve of 50TR/60TR chiller unit including takingdown old unserviceable valve complete all as specified and directed by Engineer-in-Charge .
95Material and labour for Expansion valveof 30/40TR chiller unit including takingdownold unserviceable valve complete all as specified and directed by Engineer-in-Charge.
96Material and labour Expansion valve of AC plant capacity 7.5/15 TR including taking down old unserviceablevalve complete all as specified and directed by Engineer-in-Charge.
97Taking down old unserviceable shaft seal assembly complete and Supply and fix new shaft seal assembly suitable for 15/7.5 TR Capacity chiller unitall as specified and directed by Engineer-in-Charge .
98Taking down oldunserviceable CIbutter fly valveand supply and fix new CI Butter fly valve slim seal design with nitrile rubber lined seat with clutch lever (p10)as per (ISI Marked) cast iron, PN 1.6, class 125, as per IS 13095: 1991 of the following size complete all as specified and directed by Engineer- in-charge:-
99100mm
10080mm
10150mm
102Taking down oldunserviceable Non Return valveand supply and fixing new CI Non Return valve (PN 1.6) as per IS 5312 (Part 1): 2004, of the following size complete all as specified and directed by Engineer- in-charge
103100mm
10480mm
10550mm
106Taking down oldunserviceable Strainer of any make and size and supply and fixing new Strainer of the following size complete all as specified and directed by Engineer- in-charge
107100mm
10880mm
109Supply and fixing Condensor safety valve suitable for chiller unitall as specified and directed by Engineer-in-Charge.
110Material and labour for HP cut out including taking down old one complete all as specified and directed by Engineer- in-charge.
111Material and Labour for LP cut out including taking down old one complete all as specified and directed by Engineer- in-charge.
112Material and labour for oil pressure cut out controls for compressor including taking down old one complete all as specified and directed by Engineer- in-charge.
113Removing old unserviceable power contactor and supply& fixing new power contactor MNX -32 Complete all as specified and directed by Engineer- in-charge.
114Removing old unserviceable power contactor and supply& fixing new power contactor MNX -40 Complete all as specified and directed by Engineer- in-charge.
115Removing old unserviceable power contactor and supply& fixing new power contactor MNX-18 Complete all as specified and directed by Engineer- in-charge.
116Removing old unserviceable contactor and supply& fixing new power contactor ML-2 Complete all as specified and directed by Engineer- in-charge.
117Removing old unserviceable contactor and supply& fixing new power contactor ML-3 Complete all as specified and directed by Engineer- in-charge.
118Removing old unserviceable contactor and supply& fixing new power contactor ML-4 Complete all as specified and directed by Engineer- in-charge.
119Removing old unserviceable contactor and supply& fixing new Auxiliary contactor Complete all as specified and directed by Engineer- in-charge.
120Removingold unserviceable timer from compressor panel andsupply &fix Timer 800 SD of Simens make for Compressor motor Complete all as specified and directed by Engineer- in-charge.
121Removingold unserviceable timer and supply& fixing GT Timer of L&T make for Condenser motor Complete all as specified and directed by Engineer- in-charge.
122Replacement of bimetal over load relay of range 14-23 Amps direcectly operated suitable for 10 HP motor Complete all as specified and directed by Engineer- in-charge.
123Replacement of bimetal over load relay of range 9-15 Amps direcectly operated suitable for 5 HP motor Complete all as specified and directed by Engineer- in-charge.
124Taking down old unserviceable AHU Blower and supply& fixing new AHU Blower Complete all as specified and directed by Engineer- in-charge.
125Taking down old unserviceable AHU Blower Drum and supply& fixing new AHU Blower Drum Complete all as specified and directed by Engineer- in-charge.
126Taking down old unserviceable AHU Blower shaft and supply& fixing new AHU Blower shaft Complete all as specified and directed by Engineer- in-charge.
127Taking down old existing MS pipes supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of following sizes Complete all as specified and directed by Engineer- in-charge.:
128150 mm
129100mm
13080mm
131Taking down old existing GI pipes supply, lay and welding GI pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of following sizes Complete all as specified and directed by Engineer- in-charge.:
13280mm
13350mm
13440 mm
135Removing the unserviceable liquid line valve of size 15 mm from the liquid line after pumping down the compressor & supply and fixing new liquid line valve 15 mm including connected works as required for smooth functioning of AC plants complete all as specified & directed by Engineer-in-Charge
136Removing the unserviceable liquid line valve of size 25 mm from the liquid line after pumping down the compressor & supply and fixing new liquid line valve 25 mm including connected works as required for smooth functioning of AC plants complete all as specified & directed by Engineer-in-Charge
137Removing unserviceable thermostat of central AC plant & supplying and fixing new thermostat of range 5 degrees centigrade to 25 degrees centigrade complete with all accessories all as specified & as directed by Engineer-in-Charge
138Removing the unserviceable solenoid valve assembly 5/8" flare size and Supply and fix new solenoid valve assembly 5/8" suitable for AC plant of various capacities Complete all as specified and directed by Engineer- in-charge.
139Removing the unserviceable solenoid coil and Supply and fixing new solenoid coil suitable for AC plant of various capacities Complete all as specified and directed by Engineer- in-charge.
140Removing the unserviceable chiller water sensor and supplying and fixing new chiller water Sensor of suitable capacity Complete all as specified and directed by Engineer- in-charge.
141Removing the unserviceable pressure Sensor HP / LP / OP from and supplying and fixing new pressure Sensor of suitable capacity complet all as specified & directed by Engineer-in-Charge
142Removing the unserviceable pressure gauges HP / LP / OP from existing position and supplying and fixing new pressure gauge of capacity 0 to 30 Kg / square centimeter complete with necessary accessories Complete all as specified and directed by Engineer- in-charge.
143Removing the unserviceable water pressure gauges from water line & supplying and fixing new water meter up to pressure 0 to 7 Kg / square centimeter complete with all accessories Complete all as specified and directed by Engineer- in-charge.
144Material and labour for scraping cleaning and preparation of external surface and painting complete installation at 2 X 7.5 TR (15 TR capacity) including compressor motor piping cooling tower condenser AHU and panel Board etc with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer as per ENCs colour code as given including writing to SM & MES numbers Complete all as specified and directed by Engineer- in-charge. Location : CCDT ND
145All as per item No 68.00 above but of 3 x 40 TR (120 TR Capacity) Location : MWC Bldg. No.173
146All as per item No 68.00 above but for 2 x 50TR (100 TR Capaciry)AC Plant atNAD A-63 Naval Dockyard
147All as per item No 68.00 above but for 3 x 10 TR (30 TR Capaciry) AC Plant atDockyard offr mess
148Taking down old unserviceable AHU pre filter and Supply and fix new pre filters efficiency 90% down to particular size of 10 micron double knitted twisted polymer fabric (washable) rated with press drop of 6 mm WC, including aluminium anodized frame work of 16 SWG to be mounted in AHU filter assembly size as per existing.
149Taking down old unserviceable aluminium rectangular duct grill of any size and make and supply and fix new fresh air /return air of aluminium rectangular grills complete with wooden frame work made out of II nd class hard wood, volume control damper including gasketand connected accessories Complete all as specified and directed by Engineer- in-charge.
150Supply, errect and fabricated rectangular square duct made out of 24/22 gauge GI sheet in L shaped hollow profile including all accessories such as corner, carriage bolt hangers, gasket and seal thelongitudinal joints with and including approved sealant Complete all as specified and directed by Engineer- in-charge.
151Taking down old unserviceable Duct insulation from any surface and supply and fix nitrile rubber insulation (Armaflex) of one layer of 19mm thickness sticking on Duct surface by using approved adhesive and sealing the joints by weather proof tape Complete all as specified and directed by Engineer- in-charge.
152Material and Labour for pipe insulation, cleaning the pipe surface with steel wire brush, apply one coat of zinc chromate paint and allowed to dry, apply two coats of cold setting adhesive compound on around surface of pipe, stick expanded Nitrile 50 mm thick or nitrile sheets tightly pressed, wrapped with one layer of aluminium cladding with 26 guage AL sheet suitable for covering the surface ofpipe line insulation for protection against the demage of PUF insulation slab complete for 250 mm pipe complete all as specified and directed by Engineer- in-charge.
153Ditto-all as per item No 73.00 above but 200 mm dia.
154Ditto-all as per item No 73.00 above but 150 mm dia.
155Ditto-all as per item No 73.00 above but 125 mm dia.
156Ditto- all as per item No 73.00 above but 100 mm dia.
157Ditto-all as per item No 73.00 above but 80 mm dia.
158Ditto-all as per item No 73.00 above but 65 mm dia.
159Ditto-all as per item No 73 above but 50 mm dia.
160Ditto-all as per item No 73.00 above but 40 mm dia.
161Suuply and fixing in repairs volume control damper made out of galvanized ironor anodized aluminium with overlapping leafs to avoid any leakage from the damper as per existing at site complete all as specified and directed by Engineer- in-charge.
162Suuply and fixing in repairs leather type canvas inAHU ductof any size as per existing at site Complete all as specified and directed by Engineer- in-charge.
163Cleaning of Air handling ducts(GI/AL) internally by using special T&P like robortic arm, air compressor, air jet nozzles, flipper, vaccum pump and a suction blower with hepa filterand check before and after the cleaningComplete all as specified and directed by Engineer- in-charge.
164Taking down (GI/AL) or any other type of false ceiling/ perforted board and Material and labour new perforted sheet of size 2x2 sqft complete all as specified and directed by Engineer- in-charge.