Tender For Repair And Maintenance Of Town School In Gobichettipalayam Municipality, gobichettipalayam-Tamil Nadu

Municipal Adminitration And Water Supply Department-MAAWSD has published Tender For Repair And Maintenance Of Town School In Gobichettipalayam Municipality. Submission Date for this Tender is 14-02-2024. Building Work Tenders in gobichettipalayam Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42085206
Tender For Repair And Maintenance Of Town School In Gobichettipalayam Municipality
Open Tender
Indian
Tamil Nadu
gobichettipalayam
14-02-2024

Tender Details

Repair And Maintenance Of Town School In Gobichettipalayam Municipality

Key Value

Document Fees
Refer document
EMD
INR 15000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: -Repair and Maintenance ofMunicipal Town Middle School
Sl. No. Item Description
1Dismantling the Existing damaged A/C Sheet roof in the existing building
2Dismantling of Wooden Purlin in the existing building
3Dismantling of Brickwork in the existing building
4Doors and Windows including removal of frames, hinges and fastenings
5Earthwork excavation and depositing on bank within initial lead of 10m and initial lift of 2m as sand silt or other loose soil wet sand light black cotton soil and ordinary soil including excavated earth etc., as per standard specification complete
6Earthwork excavation and depositing on bank within initial lead of 10m and initial lift of 2m as sand silt or other loose soil wet sand light black cotton soil and ordinary soil including excavated earth etc., as per standard specification complete
7Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
8Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
9Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38
10Column Footing
11Column
12Beam
13Slab
14Reinforced cement concrete 1:1.5:3 (one cement one point five sand & three aggregate) using 20mm size ISS metal including cost and conveyence of all meterials to site mixing laying consolidating working etc., but excluding cost of steel wherever neccesary fan hooks fixing etc., complete as per standard specification.
15Supply and fabricating and placing in position of M.S. or RTS of steel rods torequired size and length as directed by the departmental officers including cost of binding wire, cutting, tying etc., including cost and conveyance of all materials etc., upto 16mm dia.
16Brick work in C.M 1:5 mix (one cement & Five sand) using Chamberbrick size (9"x43/8x23/5cm) including cost and conveyence of all meterials to site and all labour charges etc., as per standard specification.
17Plastering with cement mortar 1:3 (one cement three sand) mix to 10mm thick including cost and coveyance of all materials to site finishing curing etc., complete.
18Plastering with cement mortar 1:5 (one cement five sand) mix to 12mm thick including cost and coveyance of all materials to site finishing curing etc., complete.
19Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement
20Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Door of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the door. The door should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The door should be got approved from the executive Engineer before use on work
21Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) window of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the door. The door should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The door should be got approved from the executive Engineer before use on work
22White washing two coats using best shell lime including cost and conveyance of all meterials and labour charges for finishing etc., complete.
23Painting two coatswith ready mixed plastic emulsion paint of First class quality of approved colour etc., over plastered surface including priming coat and cost and conveyence of all meterials etc., complete as per standard specification.
24Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors.
25Dismantling damaged tiles
26Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
27Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work
28Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for PVC Open light point (For Electronic regulator). (SD 18)
29Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for PVC Open Fan point (For Electronic regulator). (SD 18)
30Open Plug point (SD 36)
31Supplying and fixing of single box type 4" 40 w flu. Fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu. Tube with PVC unseathed copper leads fromterminals to the fitting.as per standard specification(SD 88)
32Supply and fixing of 1200 mm sweep AC ceiling fan complete with stepped electronic300W regulator with the existing down rod on the existing clamps. (SD110)
33GST 18%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail