Tender For Construction Of Building For Critical Care & Emergency Services In Government Stanley Hospital, Chennai-1., chennai-Tamil Nadu

Public Works Department-PWD has published Tender For Construction Of Building For Critical Care & Emergency Services In Government Stanley Hospital, Chennai-1.. Submission Date for this Tender is 08-02-2024. Building Work Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42084056
Tender For Construction Of Building For Critical Care & Emergency Services In Government Stanley Hospital, Chennai-1.
Open Tender
Indian
Tamil Nadu
chennai
08-02-2024

Tender Details

Construction Of Building For Critical Care & Emergency Services In Government Stanley Hospital, Chennai-1.

Key Value

Document Fees
Refer document
EMD
INR 5482500.0 /-
Tender Value
INR 109.44 Crore /-

BOQ Items

Name of Work : Construction of Building for Critical Care & Emergency Services in Government Stanley Hospital, Chennai-1.
Sl. No. Item Description
1Installation Charges inclusive of Transportation to site and the Boredpile equipment employed for the works including setting up of pile driving equipment with all accessories and tools at each of the pile location based on the sequence of operation approved by the departmental Engineers irrespective of the location and distance involved in movement of pile driving equipment etc., complete.
2Installation of Verticalbored cast in situ RCC piles of basic length 20 RMin all types of soil with M30 Grade using Ready Mix Concrete (Sulphate resistant Cement), Supply and erection of reinforcement, shoe, fabrication, including cost of binding wire, cutting, tying, welding and placing the reinforcement cage in correct position, driving and removing the temporary casing pipe of full depth, shifting the plant and equipments from one point to another, carryingout any ancillary work adjacent to piling work, trimming the concrete above cutoff level, cleaning the debris and levelling the site etc, as directed by the Departmental Engineers.The Rig capacity,height of Towerand length of casing pipe etc., must be adequate to take care of change in soil profile. The length of pile for payment shall be measured from top of shoe to the bottom of the pilecap.Testing of Concrete as specified in IS 456/2000 acceptance criteria as per clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site.
3600 mm dia pile having longitudinal main reinforcement of 8 Nos 20#with helical reinforcement at 8 # @ 150mm C/C with inner rings of 12 # @ 1000mm C/C with liftinghook of12 # at required length.
4750 mm dia pile having longitudinal main reinforcement of 12 Nos 20#with helical reinforcement at 8 # @ 150mm C/C with inner rings of 12 # @ 1000mm C/C with liftinghook of12 # at required length.
5450 mm dia pile having longitudinal main reinforcement of 8 Nos 16#with helical reinforcement at 8 # @ 150mm C/C with inner rings of 12 # @ 1000mm C/C with liftinghook of12 # at required length.
6Initial Load Test as per IS 2911 Part IV 1985 including cost of single pile (250% of pile capacity), labour, reinforcement charges and all other incidential charges including excavation, shoring, strutting, dewatering etc. as necessary hire charges for jacks, measuring devices, Structural Frame work for platform, Kent ledges etc, as required and providing pilecap.
7Routine load test as per IS 2911 part IV 1995 (150% of pile capacity) including labour charges for jack, measuring devices, structural frame work plot form, kent ledges etc., as required and as directed by the departmental officers etc. complete.
8Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
9Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
10Supplying and filling in foundation and basement with filling M-sand in layers of not more than 15 cm thick, well rammed watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
11Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
12Supplying and filling in foundation and basement with crushed stone dust in layers of not more than 15 cm thick, well rammed watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
13Brick work in Cement Mortar 1:6 (One cement and six sand) using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS:12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and basement and for superstructure including curing, etc.,complete complying with standard specifiction.
14For foundation & basement
15Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
16Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
17For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
18For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.,
19For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
20Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000,using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kglms and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m") 7670 kg. of sand, but excluding cost of reinforcement grill and fabricatingcharges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
21For Foundation & Basement
22Ground Floor Super Structure
23First Floor Super Structure
24Second Floor Super Structure
25Third Floor Super Structure
26Fourth Floor Super Structure
27Fifth Floor Super Structure
28Sixth Floor Super Structure
29Seventh Floor Super Structure
30Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire)
31Brick work in Cement Mortar 1:6 (One cement and six sand) using Fly Ash Bricks of 230 x 110x75mm size conforming to IS:12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and basement and for superstructure including curing,etc.,complete complying with standard specifiction.
32In Ground Floor Super Structure
33In First Floor super Structure
34In Second Floor Super Structure
35In Third Floor Super Structure
36In FourthFloor Super Structure
37Fifth Floor Super Structure
38Sixth Floor Super Structure
39Seventh Floor Super Structure
40Brick partition walls of 11cm thickness using Fly Ash Bricks of 230 x 110 x 75mm size in cement mortar 1:3 (one cement and three sand) including charges for fixing Hoop iron reinforcement if found necessary including curing etc., complete and as directed by the departmental officers. (The cost of hoop iron reinforcement shall be paid separately)
41In Ground Floor Super Structure
42In First Floor super Structure
43In Second Floor Super Structure
44In Third Floor Super Structure
45In FourthFloor Super Structure
46Fifth Floor Super Structure
47Sixth Floor Super Structure
48Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed
49Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed
50Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed.
51Providing granolithic floor finish of the 50mm thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers)
52Providing, mixing, laying polymer based water proofing treatment for the Sunken Toilet / Lift well / OHT Rcc wall by applying cement based, flexible, waterproofing compound confirming to IS:2645, to a thickness of 1mm of the prepared surface of the roof slab / floor slab as per specifications mentioned above providing cement mortar 1:3, waterproofing cover plaster to a thickness of 12mm over the membrane coating with admixture of approved make. Rate quoted is inclusive of preparation of surface, which includes cleaning of surface polymer mortar curing, labour, tools and equipment, etc. Rate inclusive ofgrouting with cement and sand required for the treatment, the cost and labour charges for fixing 25mm dia pressure pipes 15kg/cm2 to a length of 45cm for drip pipes, etc. complete.
53Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc.,with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
54Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing adding admixture SEBEX 112 etc. complete complying with standard specification and as directed by the departmental officers.
55Brick Jelly Lime Concrete of 1:2:5 (One Lime,Two Sand and Five Brick jelly ) with 40 mm hand broken brick jelly for Sunken portionsincluding dewatering wherever necessary and laid in layers of not more than 15cm thick, well rammed, consolidated and curing etc. complete complying with standard specification.
56Weathering course concrete using best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime in the proportion of brick jelly to lime being 32:12-1/2 by volume and laid over the RCC roof slab in a single layer and consolidated to the required finished thickness by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling jaggery and lime water etc. complete complying with standard specification.
57Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
58Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
59Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
60Paving the floor with best quality Double Charged Vitrified Tiles (Matt Finish) 1200 x 600 x 10mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand)20mm thick in all floors and the top pointed with the white cementmixed same colour pigments etc., complete complyinE withstandard specification. (The make and brand ofthe tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be gotapproved by Executive Engineer before use on works)
61EPOXY FLOORING Flooring is of 2mm thick self level epoxy flooring with antistatic and anti microbial property. and Flooring should be shock proof, scratch proof , flame retardant and antimicrobial. The Corners should be uniformly curved. Final Surface should be noncorrosive to biological fluids and detergents. The Color should be uniform, pleasant and matching with ambience . It should be inert to body fluids, chemicals and disinfectants and should not be affected by temperature variation.Flooring installation should be done by skilled workers of accredited agencies authorized by the supplier ofEpoxy Material. The corners should not be terminated sharply and concealed cover-former (aluminium) should be used overlapping the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self-levelling compounds should be used for this purpose.
62FLOORING - SEAMLESSVINYL FLOORING WITH ANTI STATIC AND ANTI MICROBIAL PROPERTY It shall be self leveling 3.00inm anti static seamless PVC flooring. Floorshallbe smooth,non-slip,imperviousmaterialconductiveenoughto dissipate static electricitybutnot conductiveenoughto endangerpersonnel from electric shock It shallbe Electro Static Discharge (ESD) combatPVC seamless flooring of veryhighqualitythicknessnotlessthan2.00mm.Continuousrollshallbe usedandwithminimumjoints.TheJointstobeweldedbyspecialPV thermalunits using PVC welding bars of same colors. The sheet shall be highly durable to shock and indentation.It shall be scratch proof,inerttobodyfluids,chemicals anddisinfectants &shall notbe affected by the temperature variations. Theflooringshallbedonebyskilledworkersoftheaccreditedagencies, autlioi‘izedby the supplier of PVC sheets. The Electricalresistance (Pointto ground)shallbewithin2.5X104to5X106Ohms.Thefloorshallnot allowbuildupofElectricalchargesbeyond100Vduetoantistaticeffect. Thecornersshallnotbeterminatedsharply&concealedcovingshallbe used tooverlap thewallpaneltoaheightofapprox.25mm&sealed perfectly & uniformly. Selfleveling compounds shall be used
63Supplying fabricating & Fixing in positionwall cladding using stainless steel sheets made-up of SS304 (Equivalent to IS 6911-04, Cr 19, Ni 19) 1.6 mm thick minimum 8 - 8.5 % nickel and 18 % chromium sourced from original stainless steel manufacturer with plastic surface protection taping that can be pleaded out after installation the sheets should be clipped to the clips which were to MS frame made of 50 x 50 x 4 mm MS angles run at both direction well anchored on the wall with necessary clamps , wooden plugs etc., at 1m interval on both directions the clip and the frame .Work should be Tigwelded using 308 L grade SSS electrode, the stainless steel joints have to be welded to have proper joints less panelling , to upkeep the sterility inside the theatre with proper packing with bisonboard. The plastic tape has to be pleaded off after completing all the works and fine cleaning has to be done with acetone for shining etc. complete as specified by the dept. officer
64Supplying fabricating & Fixing in position false ceiling using stainless steel sheets made-up of SS304 (Equivalent to IS 6911-04, Cr 19, Ni 19) 1.6 mm thick minimum 8 - 8.5 % nickel and 18 % chromium sourced from original stainless steel manufacturer with plastic surface protection taping that can be pleaded out after installation the sheets should be clipped to the suspended stainless anchors made out of 25 mm stainless steel angles of 3mm thick and SS 304 grade forming 1 m grade points. The horizontal members shall be TIG welded to the stainless steel anchors to from the clip on grid. The Suspended shall be held with stainless steel grip bolts and plates, the length of suspended anchors will depend on the room size and the height at which the false ceiling is desired. The horizontal joints should be kept to minimum, suitable adhesive of Eg.Silica gel is to used between horizontal segments so that the joint between two segments is not more than 0.2mm. The plastic tape has to be pleaded off after completing all the works and fine cleaning has to be done with acetone for shining etc. complete as specified by the dept. officer
65Flooring with Self design Joint free rectified Ceramic Tiles ofsize 600 x 600 x 6mmlaid over 20mm thick cement mortar 1:3 (Onecement and Tree sand) base mortar over the existing slab / floorincluding cutting the tiles to the required size with special cutter wherever necessary, laying in positionand and pointing with whitecement mixed with colouring pigment at the rate of 0.3 kg. / sq.m.etc., complete complying with standard specification. (The makeand brand of the tiles should be Johnson / Kajaria / Somany / Nitco/ RAK or Equivalent which has to be got approved by executiveEngineer before use on works)
66Dadooing walls with Joint free rectified Colour designed digital print ceramic tiles, with borders, with size of 600mm x 600mm x 8mm and above setin Cement Mortar 1:2 (One Cement and Two sand) 20mm thick andpointing the joints with white cement mixed with colouring pigmentsat the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc,complying with standard specification and as directed by thedepartmental officers. (The make and brand of the tiles should belike Johnson / Kajaria / Somany / Nitco / RAK or Equivalent whichhas to be got approved by Executive Engineer before use on works)
67Clading the walls by supplying and fixing of White Galaxy or equivalent quality of granite vertical slab for an average thickness of 17 mm to 20mm for vertical surface over a base layer in cement mortar 1:2 10 mm thick and pointing with the same mortar as directed andagmi, Aroldate and POP Paste for fixing the granite slab in position wherever necessary. The quality and colour of granite slab should be got approved by the Executive Engineer before use on works
68Supplying 18 to 20 mm thick white jet blck granitepartition slab for urinals of 1200 x 600 (Avg) mm size fixing to wall using3Nos.of suitable chromium plated brackets with CP bolt and nets, washers, cutting to required shape polishing to all the expose and surfaces and edge grinding etc, complete as directed by the dept officers.
69Providing grooving to granite slab at the intermediate edges of the vertical face with neat finishing etc complete with standard specification and as directed by the departmental officers. The cost including higher charges of machines and labour charges etc complete
70Providing Double semi nosing to granite slab at the edges of the vertical space with neat finishing etc complete with standard specification and as directed by the departmental officers. The cost including higher charges of machines and labour charges etc complete
71Providing and Fixing of PVC Trims (Corner beeding) at the outer corner profiles of the tiles including cost of material, labour and handling etc. as directed by departmental engineersat site of work and as per standard specification.
72Supplying and applying of two coats of Ceiling Putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand prepared (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the departmental officers.
73Supplying and applying Putty with two coats of plastered wall surface of first class quality and of approved including thorough scrapping, clean removal of dirt wherever required etc., complete complying with standard specification.
74Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
75Textured wall painting with exterior weather proof emulsion paint (2 coats) of approved quality and colour over a priming coat including through scrapping, clean removal of dirt etc., complete and including necessary plaster of Paris, putty whereas required as directed by the departmental officers.
76Supplying and fixing Teak Wood frames for doors Windows and Ventilators using required MS angles, flats and rods of approved design and as directed by the departmental officers including cost of MS Grills, labour charges and cost of one coat of red oxide primer with labour charges for priming coat etc. complete complying with standard specifiction.
77supplying, hold fast of M.S flats of over all size of 330x50x6mm suitably folded to the required L shape have two end of lap of 50mm long each and overall length of the horizontal portion as 230mm & including making necessary grooves in two end laps to accomadate screws etc., complete.
78Supplying and fixing in position of Teak wood door shutter using spl quality teak wood planks of 40 mm thick panelled doors with required raw materials, Brass hinges, Brass tower bolt,ornamental Brass handles, Door stopper, Door closer,Brass aldrops and bush with suitable locking arrangements etc. The rate should be inclusive of cost of materials, labour charges for wrought and put up the doors with kadasal charges and transporting charges etc complete complying with standard specification and as directed by the Departmental officers.
79FRAME:Fully Solid Core WPC-75MMX50MM:Providing and Fixing of Qute WPC/PVC Solid Door frame extruded with size 75mmx50mm.The inner core made of rigid WPC Compound with minimum shore hardness of 55,and Bulk Density 0.8 Grms/Cub.C.mt.The frame shall be fixed fixed to the wall using 10x100mm long M.S.Screw through the frame by using PVC Fasteners.A minimum of 4nos screws to be provided for each vertical member.
80Supplying and fixing solid core flush shutter 35mm thick with teak ply on both sides,teak lipping alround with necessary adhesive and C.P.screws, including fixing of aldrop , tower bolt, hinges , door stopper with Nylon bush and lock strike plates , putty, fevical etc., complete . All aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 for anodic film thickness of not less than 15 microns. The rate is inclusive of cost of fevical, fixing charges,polishing, transportation, loading, unloading all other incidental charges and handling charges etc., complete complying with standard specification.
81Single leaf
82Double leaf
83Supplying, fabricating and fixing in position factory made stainless steel Flush door shutter 35mm thick using SS 304 Grade 1.6mm thick, Stainless sheets on both sides( Equivalent to IS 6911 - 04 Cr.19,Ni 9) minimum 8-8.5% nickel and 18% Chrominum sourced from original stainless steel manufacurer with view panel size 30mmx45mm made up of 6mm thick clear toughened glass fitted with double side adhesive tape and finished with dowconing silicon sealent floor spring for each shutter consealed tower bolt suitable stainless steel locking arrangement and other necessary furniture fittings of approved quality.The vertical styles and other frame members and cross stiffeners shall be of same quality stainless steel box section of suitable size and thickness with proper core material as prescribed by the departmental officers.(Doubles Leaves)
84Polishing the teak wood shutters with two coats of Melamine polish to wood surface as per direction etc., complete should be got approved by the Executive Engineer before use on works.
85Supplying and fixing Fully Solid Core WPC-75MMX50MM:Providing and Fixing of Qute WPC/PVC Solid Door frame extruded with size 75mmx50mm.The inner core made of rigid WPC Compound with minimum shore hardness of 55,and Bulk Density 0.8 Grms/Cub.C.mt.The frame shall be fixed fixed to the wall using 10x100mm long M.S.Screw through the frame by using PVC Fasteners.A minimum of 4nos screws to be provided for each vertical member
86Supplying and fixing of wood polymer composite (WPC) door with solid door frames extruded with size 75mmx50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55 and buld density 750kg/cub.Mt. The frame shall be fixed to the wall using 10x10mm long MS screw throught the frame by using PVC fasteners. A minimum of 4nos screw to be provided for each vertical members, Door Shutter of 25mm thick Wood Polymer Composite (WPC) single core Extruded Door Shutter, with one side digital printing of specified Design which is approved by engineering-in-charge. Both side of the shutter shall have rough sugar texture finish, laminated with UV oil. The solid WPC board shall have minimum shore hardness of 55 and Bulk density 550kg/cub.Mt moulding the thickness remains 25mm (+/-1mm) etc. complete as per the direction of the departmental officers.(make Qute / Equivalent)
87Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
88Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI 1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
89Manufacturing, Supplying and fixing of Steel doors with following specification. MS Angle of size 40 x 40 x 6mm at 3.5 kg/m used for outer frame and MS Angle of size 35 x 35 x 5mm at 2.6 kg/m for the shutter frame.Stiffeners with 32 x 6mm at 1.5 kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame.18 GCR Sheets of best quality is laid as panel in the shutter frames.18 x 5mm at 0.70 kg/m MS Flat is welded over the 32 x 6mm at 1.50 kg/m MS Flat on the rear side of the door, sand witching the CR Sheet for rigidity.Additional stiffeners with 18 x 5mm at 0.7 kg/m MS Flats are provided diagonally on the rear side of the shutter.2 Nos.of hinges in case of single leaf and 4 Nos. of hinges in case of double leaf shutters is provided.6 Nos.of hold fasts 200mm length spliced at the ends are welded to the outer frame of the door.Tower bolt 2 Nos.one at the top and the other at bottom
90Supplying and fixing of M.S. grill of approved design for open courtyard, grill, grill work to doors and window openings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including cutting the members, welding, grinding, one coat of priming coat using best approved quality red oxide primer,dismantling of walls /concrete if necessary, fixing and finishing the dismantled portion to original condition etc., complete complying with standard specification.
91Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
92Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc.complete
93Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mmdiaof1.60mmthickweldedtotherailing.The supports will be groutedinto the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supportingarrangementsthehandrailinfloor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
94Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
95160mm dia
96110mm dia
97Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 Part I to IV in stages to suit the progress of work consist as per the detailed specification as below.(Measurements taken for the plinth area for the purpose of payment) including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing, etc., complete and as directed by the departmental officers.(The chemical should be got approved by Executive Engineer before use on work).Stage-1: Spraying anti-termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation.Stage-2: Spraying anti-termite chemical solution to the grade beam level, spraying has to done for the grade beam, brick masonry contact with the back fill earth.Stage-3: Spraying anti-termite chemical solution on the sand for the flooring before laying the flooring concrete.This treatment has to be carried out on the sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring thoroughout.Stage-4: Spraying anti-termite chemical solution alround building outside by making holes through bar before laying plinth protection and the holes to be closed after the treatment
98Providing and fixing 8 mm thick fully designed perforated calcium silicate board 2"x2" panel tiled false ceiling (Hilux) includingsupplying and fixing true horizontal level false ceiling with 24mm prelude grid system Using hot dipped galvanised steel section exposed surface chemically cleaned caping prefinished in backed polyester paint wall angle of size 3000x19 x19mm used in the periphery of the ceiling fixed to the wall, parttion with the help of screws at 600mm c/c. Mainrunner of size 3000x24mm suspended at a 1200mm c/c by using securely fixed to the structural soffit of RCC slab by using 6mm Nylon Rwl plug at every 1200mm(max)and 1200mm long cross tee of size 1200x24mm to interlocked between mainrunner at 600mm c/c(max) to form a grid of size 1200x600mm.600mm long cross tee of size 600x24mm is inserted to form a grid of 600x600mm and finally laying classic lite regular edge tiles of size 600x600x15mm
99Supplying and Installing Metal false ceiling using fire retardant galvanized steel sheet plain lay-in-tile of size 600 x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest in the exposed grid system to give a600 x 600mm centre to centre ‘T’ THE ‘T’ shall be not dipped GS tee section 3600mm long main tee.24mm wide and cross tee 1200mm / 600mm to from grid of 600mm x 600mm. the grid for placing the panels are formed by running main runner of ‘T’ section of size 30mm x 24mm powder coated at bottom at intervals of 1200mm centre to centre and cross runners of ‘T’ section of size 20 x 24mmat 600mm intervals with powder coating at bottom. Necessary provision for interlocking of ‘T’ sections are made at required intervals not exceeding 1200mm. the main runners are suspended from the ceiling by means of 4mm diaGi rods fixed to the ceiling using anchor fasteners of 50 x 8mm size with nylon inset and hooked to the main rubbers using clip arrangements.The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed be placed at the side wall using edge.etc as per std. specifications
100Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works).
101Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC /12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition,etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting
102Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.)
103Supplying and fixing in position best quality and approved make Indian made white/colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
104Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
105Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, SS clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The UPVC pipes shall be got approved by Executive Engineer before use on works.
10620 mm dia UPVC Pipe
10725 mm dia UPVC Pipe
10832 mm dia UPVC Pipe
10940 mm dia UPVC Pipe
11050 mm diaUPVC Pipe
111Supplying and fixing in position first quality and approved Gun Metal Gate valve /wheel valve /check valve (Heavy Type) with ISI mark of the following sizes including cost of shellac,thread etc., Including labour for cutting and threading of GI Pipe etc.,Complete Complying with standard Specfications for both internal & External Water supply arrangements
11225 mm dia G.M. Wheel Valve
11332mm dia G.M. Wheel Valve
11440 mm dia G.M. Gate Valve
11550 mm dia G.M. Gate Valve
116Supplying and fixing in position 15mm dia following taps (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works)
11715mm dia CP Pillar Tap
11815mm dia Long body Tap
11915mm dia Stop Cock
12015mm dia Swan Neck Tap
121Supplying and fixing in position 15mm dia two way bibcock(heavy duty) with Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works)
122Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.50mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
123Supplying and fixing approved best quality brass CP towel rail 600mm long of approved make with brackets of same materials including cost of teak wood plugs and CP screws, etc.,complete complying with standard specifications.(The tower rail should be got approved by Executive Engineer before use on works).
124Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works).
125Supplying and fixing coat hook with twin arms heavy tube to rear of wooden shutter of WC cubical,use of S.S screws etc,complete asdirected by the dept officers.
126Supplying UPVC Specialsin water supply arrangements (both in internal and external water supply arrangements
127UPVC Elbow
12850 mm dia
12940 mm dia
13032mm dia
13125 mm dia
13220 mm dia
133UPVC Tee
13450 mm dia
13540 mm dia
13632mm dia
13725 mm dia
13820 mm dia
139UPVC Reducer
14050x40mm dia
14140x32mm dia
14232x25mm dia
14325 x 20 mm dia
144UPVC Reducer Elbow
14550x40mm dia
14640x32mm dia
14732x25mm dia
14825 x 20 mm dia
149UPVC Reducer Tee
15050x40mm dia
15140x32mm dia
15232x25mm dia
15325 x 20 mm dia
154UPVC Hex Nipple
15550 mm dia
15640 mm dia
15732mm dia
15825 mm dia
15920 mm dia
160UPVC Union
16150 mm dia
16240 mm dia
16332mm dia
16425 mm dia
16520 mm dia
166Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap "A" grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.
167Supplying and fixing in position best quality PVC soil / waste pipes of various dia having6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
16875mm dia PVC soil waste pipe
169110mm dia PVC soil waste pipe
170160mm dia PVC soil waste pipe
171Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
172PVC Elbow
173160mm dia
174110mm dia
17575mm dia
176PVC Elbow with Door
177110mm dia
17875mm dia
179PVC Tee
180110mm dia
18175mm dia
182PVC Tee with Single Door
183110mm dia
18475mm dia
185PVC Y
186110mm dia
18775mm dia
188PVC "Y" with Single Door
189110mm dia
19075mm dia
191PVC bend
192110mm dia
19375mm dia
194Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works).
19575 mm dia
196110 mm dia
197Construction of Inspection chamber or manhole of the following size including necessary earth work excavation in all soils to full depth as may be directed with sand filling at bottom of the chamber for 10cm thick, concreting CC 1:5:10 using 40 mm guage HBGs jelly 10 cm thick and sode walls 9" thick brick work in cement mortar 1:5 using Fly Ash Bricks of 230 x 110 x 75mm filling the size of foundation with excavated earth, plastering with cm 1:3 20m thick for inside and bottom and making necessary benching with brick jelly cement concrete to the required slope and finishing neatly etc., complete.
198Inspection Chamber of Size 0.60 x 0.60 x 0.60m (average depth)
199Inspection Chamber of Size 0.60 x 0.60 x 0.90m (average depth)
200Supplying and fixing in position of Steel fibre reinforced cement concrete (SFRC)manhole / inspection chamber cover slab with framesize 0.60x0.60m including necessary labour charges for fixing the frame in position over the cement mortar base and finishing the joints etc. complete as directed.
201Supplying and fixing of CI steps of approved quality including dismantling masonry wherever necessary and redoing the damaged portion to original condition
202Providing PVC Water Bar 150mm wide with singel bulb of approved quality and brand and including fixting etc complete complying with standard specifications and as directed
203Providing rain water harvesting pit of 1.50m dia and 1.50m depth with necessary earth work excavation,erecting the five nos of Rcc collar of 1.50m dia,sand filling of 0.60m depth,filling of 40mm HBS Jelly of 0.60m depth and covering with Rcc cover slab of 50mm thick and also connecting 110mm dia PVC pipe of 10.00m legth including transporting charges,fixing,etc.complete.
204Drilling bore wells anywhere in Tamilnadu including transportation from one place to another within Tamilnadu in alluvial soil sedimentary strata of clay and sandstone shale pebbles boulders etc, by first taking a pilot bore of 140mm / 150mm dia and then enlarging to required dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drillng at site etc complete complying with standard specification and as directed by the departmental officers. Upto 60M Depth.
205Reaming 140 / 150 mm dia pilot bore to 300mm dia bore etc complete complying with standard specification and as directed by the departmental officers.Upto 60m depth ending below ground level.
206Supplying of PVC casing pipes 160mm assembly (With slot or without slot) in the drilled hole including welding the joints etc., complete supplying and packing the annular space with pebbles of size and quality as approved by the Executive Engineers
207Slotted pipe 160 mm Dia
208Plain pipe 160mm Dia
209Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.
21010mm OD 0.90mm thick copper pipe
21115mm OD 0.90mm thick copper pipe
21222mm OD 0.90mm thick copper pipe
21328mm OD 0.90mm thick copper pipe
21442mm OD 1.20mm thick copper pipe
215DIN / BS Standard Outlet Points with from loading, inner connecting and brass body. Single press inlet with two stage process first stage for patient usage and second stage in parking mode, covered by plastic cover duly colour indicated with specific gas name and non inter-changeable for other gases. The cost of materials inclduing transport, etc., complete, as per standard specification and as directed by the Departmental Officers
216Oxygen manifold arrangements of 2 banks x 12 cylinder each wing with semi automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282- 1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) Mainfold top frame with provision for connecting 12 cylinders on right bank and 12 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder spport middle angle frame for claping 2 x 12 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg. / CM2. The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.
217Nitrous Oxide Manifold Arrangements of 2 banks x 3 cylinder each wing, with automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IOX regulator 2 Nos. with suitable adopter, flexible SS hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarams with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) 2 x 3 cylinder Nitrus Oxide Manifold should be suitable with stand a pressure of 140 Kg. / Cm2 and above along with high pressure copper annealed tail pipes with end brass adapter suitable for Nitrous Oxide Cylinders and manifold. 2) Top frame comprising of high pressure copper pipes of size 12mm ID 1.5mm wall thick with high pressure brass fittings made of high tensile brass and connections through non-return valves, high pressure copper tail pipes made of high pressure copper pipe size of 7mm ID x 1.5mm thick. 3) The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely with fitted heavy duty regulator. The Manifold should be tested at 3500 pig as per IS 12827 / 1989 & ISO 7396 / 1987 Specification
218Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber "O" ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827
21915mm Isolation Valve
22022mm Isolation Valve
22128mm Isolation Valve
22242mm Isolation Valve
223Supply, installation, testing and commissioning of equivalent to Ingersoll Rand Reciprocating Air Cooled Type (10 HP) Rating Vaccum Pump as per following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specification a) Vaccum Pump - 10 HP - 1 No. b) Electric Motor - 10 HP - 1 No. c) DOL Starter with OLR - 1 No. d) Vaccum Switch - 1 No. e) Vaccum Gauge - 1 No. f) Control Frame with Fittings - 1 No. g) Suction Scrubber - 1 No. h) V-Belts - 1 No. i) GI & MS Fittings - 1 No. j) Brass Fittings - 1 No. k) Exhaust Silencer - 1 No. i) Base Frame for Motor and Vaccum Pump - 1 set m) Pilot Line with Fittings - 1 set, Vaccum Room & Air Compressor Room Inside
224Supply, installation, testing and commissioning of Compressed Air System of Reciprocating Oil Free Air Compressor Belt Driven Type 15 HP Air Compressor with following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specification Compressor package consists of following: a) 15 HP Air Compressor - 1 No. b) Electric Motor 10 HP - 1 No. c) Dol Starter - L&T - 10 HP - 1 No. d) Base Frame Kit (for Motor and Compressor) - 1 set e) Pressure Swith - 1 No. f) Pressure Gauge - 1 No. g) NRV and Pilot Fittings - 1 No. h) Delivery Tube - 1 No i) Foundation Bolts & Anchor Fasteners - 1 Lot j) Belt Guard - 1 No. k) Refrigerator Type Air Dryer-60 cfm. capacity-1 No. l) Drain Ball Valve - 1 No. m) Air Outlet Ball Valve - 1 No. Vacuum Room & Air Compressor Room Inside Accessories: Non-Return Valves, Air Pressure Switch, Pressure Gauge, Isolation Valves, Air Filters etc., Inter connecting piping: Mild Steel Pipe of 2" with fittings.
225Supply, installation, testing and commissioning of MS Fabricated Vertical Mounted Type 1000 liters capacity Vaccum Receiver with inlet and outlet and drain holes provided suitable to operate with vaccum pump, etc., as directed by the Departmental Officers.
226Supply, installation, testing and commissioning of MS Fabricated Vertical Mounted Type 1000 liters capacity Compressed Air Receiver with inlet and outlet and drain holes provided suitable to operate with vaccum pump etc as directed by the Departmental Officers.
227Bed Head Panel of size 1m length, hSeventh 0-0.30 cm and depth of 4".The aluminium powder coated with requirement colour for provision points of O2-2 Nos., Air 1 No., Vaccum 1 No. with double electrical socket with switch 2 Nos. with 2 set with 1V - bottle holder fixing to the wall hanging including monitor stand etc., complete.
228Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per miniute. It should meet strict permission and dumbling standard. The meter body should be made of brass materials. The humidifier bottle should be made of unbreadkable polycorbonate material and auto cleavable at 134 degree centigrate. The includes flow meter and its accessories (silicon tube with mask.) The cost of materials including transport, etc., complete as per standard specification and as directed by the Dpartmental Officer and as per IS 12827/1987 & ISO 7396/1987
229Ward Vaccum Unit with Gauge both mounted on a collection jar of capacity 600 ml and with a wall bracket for mounting it on the wall. The collection jar should be made of unbreadkable polycarbonate materials which is fully auto cleavable at 134 degree centigrade as per standard specification and as directed by the Departmental Officer and as per IS 12827/1989 & ISO 7396/1987 Specification . The rate includes cost of silicon hose with SS nipple on either side.
230Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled holeincluding jointing the pipes with PVC Couplers with cement paste etc. complete, cost including supply and packing the annular space with pebbles of size and quality etc complete complying with standard specification and as directed by the dept officers.
231Charges for developing the bore well with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor etc complete complying with standard specification and as directed by the departmental officers.
232Supplying laying and jointing HDPE pipes of 10kg/cm2 for borewell motor purpose of approved quality etc., complete and as directed by the departmental officers.
23340mm Dia
23425mm Dia
235Paving the floor with best quality approved Tactile Paver Type of New Tek BT Yellow Colour Ceramic Tiles of size 305 X 305 X 15mm for Vision Impairment Person.laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
236Supplying and laying Paver Block of 63mm thick approved design madeout of 6-10mm thick HBGS chips in cm 1:2:4 properly Occurred to attain the required strength laying the rubber Moulded paver block and well Compacted using 1-3 tonne capacity of manufacturing the inter locking blocks,loading,transportation,unloading and other incidential charges etc., complete complying with standard specification.
237Supplying and fixing Lapato finished granite slab of size 1200x600 of 20mm thick necessary raw materials etc., The rate is inclusive of cost of materials, labour charges and transporting etc., complete as directed by the departmental officer.
238Supply and fixingof Fire fighting applicationoblique type stainless steel Hydrant Valve (Single Headed) of size 63mm –dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E” , bolts & nuts with washer as per IS 5290 atring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.(Make;OMEX/KARTAR/LIFE GUARD/SAFE GUARD/EQUIVALENT.
239Supply, Installationof Fire fightingapplication180 degree swinging type, hose reel drum with 20 mm diabraidedthermoplastichose of 30 metres long so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm diaball valve & open & close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve,including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.(Make;OMEX/KARTAR/LIFE GUARD/SAFE GUARD/EQUIVALENT. as directed by the department officers.
240Supply, and fixing in positionof Fire fighting application Hose of 63mm dia of 15mts length binded by copper wire with 63mm dia Stainless steel male and female instantaneous fire fighting special coupling as per IS 901 asdirected by the department officers Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.(Make;OMEX/KARTAR/LIFE GUARD/SAFE GUARD/EQUIVALENT.
241Supply, and fixing inpositionofFire fighting application 63mm dia stainless steelshort length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.(Make;OMEX/KARTAR/LIFE GUARD/SAFE GUARD/EQUIVALENT..
242Supply of Fire fighting applicationM.S. Hose Box to keep two number ofHoses and one number of branch pipe with nozzle. having proper glass window type double door with universe open key, painted inside white and outside PO red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers. (Make: OMEX/KARTAR/LIFE GUARD/SAFE GUARD/EQUIVALENT.
243Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, Shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.(Make;OMEX/KARTAR/LIFE GUARD/SAFE GUARD/EQUIVALENT. as directed by the department officers.
244Supply, erection, testing and commissioning ofMS ‘C’ Class heavy duty pipe as per IS 1239, to withstand a developing pressure of 10 kg/Sq.cm including necessary fittings like MS flange of table ‘E’, Elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding. Includingone coat metal primer and two coat P.O red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.Make;JINDAL/EQUIVALENT.
245150 mm dia MS ‘C’ Class heavy duty pipe
246100 mm dia MS ‘C’ Class heavy duty pipe
24780 mm diaMS ‘C’ Class heavy duty pipe
24850 mm dia MS ‘C’ Class heavy duty pipe
24925 mm dia MS ‘C’ Class heavy duty pipe
250Wrapping and coating anti-corrosive treatment for under ground MS pipe having one coat of anti-corrosive metal primer, one layer of Asphalt Tar tape wound over the M.S Pipe as per standard methods as per standard specification as directed by the departmentalofficers.
251150mm dia anti-corrosive treatment for under ground MS pipe
25280 mm dia anti-corrosive treatment for under ground MS pipe
253Supply, erection, testing and commissioning of following sizesheavy duty foot valveincluding all accesories such as MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at end of 150/200mm dia suction pipeline at sump including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.Make:NORMEX/KARTAR
254150mm dia heavy duty foot valve
255Supply, erection, testing and commissioning of 80mmheavy duty foot valveincluding Necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at end of 80mm dia suction pipeline at sumpas per standard specification and as directed by the departmentalofficers.Make:NORMEX/KARTAR
256Supply, erection, testing and commissioning of Cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.Make:NORMEX/KARTAR
257150 mm dia spindle sluice valve
258100 mm dia spindle sluice valve
25980 mm dia spindle sluice valve
260Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of followingsizes to control one way flow of water to be installedpump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 . including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.
261150 mm dia Non-return valve
262100 mm dia Non-return valve
26380 mm dia Non-return valve
264Supply, erection, testing and commissioning ofGun metalGate valve of size 50mm dia size including necessary MS flange of table ‘E’, gaskets, bolts & nuts etc.,installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.Make:LEADER/EQUIVALANT.
265Supply, erection, testing and commissioning of Gun metalnon-return valve of size 50 mm diaincluding necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc.,installed at pump house delivery line for the purpose of priming to suction line so that to control one way including conveying ,fixing and incidental charges etc completeas per standard specification and as directed by the departmental officers.Make:LEADER/EQUIVALANT.
266Supply and providing 1000 Litres capacity priming tank made up of PVC.Make:SINTEX/EQUIVALANT
267priming tank mounted with the supporting arrangement fabricated using MS angle for the height of 3.00 mtrs from the floor level, inlet,outlet, and drian arrangements inside the fire fighting pump room as directed by the department officers.
268Supply and laying of following sizes of armoured Aluminium/Copper cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers. Make: POLYCAB / PARACON / FINOLEX / EQUIVALENT.
2693 Core 185 sqmm armoured Aluminium cable
2703 Core 10 sqmm armoured Copper cable
27110 core 2.5 sqmm armoured Copper cable
2723 Core 95 Sq.mm Armoured aluminium cable
2732 Core 1.5 Sq.mm Armoured multi strand aluminium cable
274Supply, erection testing and commissioning of Fire Fighting Application Horizontal Centrafugal type pump rated for 2280 LPM at 70 Meters head with Eletrical Motor of 60 HP of 415 volt 3 phase connection complete with base plate and accessories. (Make: Kiriloskar or Equivalent). The rate inclusive of neccessary vibration, bad mounting etc., as per standard method as directed by the Departmental Officers.
275Supply , Installation , Testing and commissioning of Diesel engine driven main Fire Pump suitable for automatic operationand consisting of following complete in all respects as required. (a) End Suction, top discharge centrifugal pump of cast iron body & Bronze impeller with stainless steel shaft, mechanical seal to ensure minimum pressure of 3.5kg / sq. cm. at Highest and farthest outlet at specific flow of 2280 LPM. b) 68 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete.Auto starting mechanism, 12 volts/24 volts electric starting equipment like self Motor,Dyanamo, Solenoid switches etc., c)110 ltrs capacity Diesel tank mounted over stand fabricated using 25mmx25mmx6mm size MS angle,providing with level indicator,inlet port,outlet port, drain port and deisel return line port and fuel pre filter,after filter etc., d)exhaust system having flexible metallic mufler,100mm dia MS heavy pipeextended upto 1m. outside pump house duly insulated with 50mm thick glass wool with 1.00 mm thick aluminium sheet cladding,residential silencer with necessory MS support arrangements from wall or ceiling as per site condition. e)Dash Board consisting the Instruments like Temperature Gauge,Galvano type DC Ammeter, Lub oil Pressure Gauge, Ignition switch,Emergency Stop and all other protection equipment as per specification , stop soloneid for auto stop in the event of fault with audio indicatios, painted with post office red colour etc as required. f)12 V / 24 V , storage battery, maintenance free tape , 180 AH rating. M.S fabricated common base plate, coupling guard, foundation bolts etc as required. g) Postioning the Diesel Engine driven Fire Pump over cement concret foundation using suitable size Anti Vibration mounting arrangements. All works including conveying ,fixing and incidental charges etc completeas per standard specification and as directed by the departmental officers. Make: KIRLOSKAR / EQUIVALENT."
276Supply, erection, testing and commissioning of 180 LPM 70 metres Head Pressurization pump with 10HPelectrical motorof kirloskar make with suitable base frame, Includingnecessary vibration bad mountingetc., including conveying ,fixing and incidental charges etc completeas per standard specification and as directed by the departmental officers. Make: KIRLOSKAR / EQUIVALENT.
277Supplying ,installation , testing and commissioning of Fire Fighting electrical control panel of cubical construction ,floor mounted type fabricated using CRCA sheet ,compartmentalised with hinged lockable door dust,and vermin proof, cable alley,inter connection, having switch gears and accessories mounting and internal wiring, earth terminals, numberings, necessarymetering protections & indications complete in all respect ,suitable for operation on 415volt,3 phase,50 Hz AC supply with enclosure protection class IP 54and mounted with the followings.
278A: Common Panel in Fire Pump House (i)Incomer a) 1 No 600A TP&N sdfu with HRC fuses b) 1 Set of 600A, 4 bar Aluminium bus bar, 415V, 50HZ AC supply c) 1No (0-500A) digital ammeter with selector switch & CT’s d). 1 No (0-500V) digital voltmeter with selector switch & control fuses. e).3 Nos. phase indication lamp LED Type with toggle switches with control fuses.
279(ii)Outgoing a.Main Fire Pump 400 A TPN SDFU with HRC fuses with suitable HP fully automatic starter / delta starter with over load protection, digital ammeter with built- In selector switch and suitable CTs, current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic operation, selector switch for auto / manual / OFF operation-1No.....
280(b)Jockey Pump 2. 125 A TPN SDFU with HRCfuses with suitable HP fully automatic Star/Delta starter with over load protection ,current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic operation ,selector switch for auto /manual operation- 1 No (c)Diesel Engine Control Comprising:- (a) Auto/manual selector switch & 3 attempt starting device,timers and relays asrequired, push buttons, start/stop in manual mode. (b) Indication lamp for High/low Lub oil pressure,High water Temp. and Engine ON indication. (c) Battery charger suitable for 12 V/24 V DC with boost and tickle selector switch,0-15V/0-30V DC volt meter, 0-20A DC Ammeter. (d) All standard relays and accessories for automatic operation of diesel engine. (e) The above Combined panel mounted over M.S Channel Fabricated Frame with Cement concrete Plotform, all other connection works carried out as per standard methods and including conveying ,fixing and incidental charges etc completeas per standard specification and as directed by the departmental officers. Make: FABRICATED AS PER STANDARD .
281Supply, erection, testing and commissioning of Fire fighting4 way fire brigade inlet with necessary Gun metal 63 mm dia non return spring shutter arrangements so that to control one way flow at the time of emergency water supply by fire andrescue service fire engineentry , including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers. Make: KIARTAR/OMEX/ EQUIVALENT.
282Supply, erection, testing and commissioning of Air release valve of 20mm dia so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.Make: KARTAR / EQUIVALENT.
283Earthing arrangements with GI earth plateincludingcharcoaland saltwith necessary excavation in all soils and to full depth as may be required and masonry work, refilling the sides of foundation with excavated earth as per the standard specification and as directed by the department officers.
284Supply, erection, testing and commissioning ofPressure Gauge with 0 to 14kg range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers.Make: H- GURU / ISI MAKE / EQUIVALENT.
285Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line indfos or Donfos including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start & auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmentalofficers. Make: DONFOSS/ INDFOSS / ISI MAKE / EQUIVALENT.
286Supply and fixing of stored pressure ABC (Mono Ammonium Phospate)powder type Fire Extinguisher of 6 kgs capacity as per IS:15683 with pressure gauge,discharge hose& control nozzle,wall mounting bracket,safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmental officers.Make: EXCELLENT/SAFETY FIRST / EQUIVALENT
287Supply and fixing of carbon-di-oxide Gas type 2 kg capacity Fire Extinguisher as perNew IS No.15683complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc completeas per standard specification and as directed by the departmental officers. Make: EXCELLENT/SAFETY FIRST / EQUIVALENT
288Suppling and fixing position of polycorbonate sheet (Opaque White) roofing with following specification. The roofing made of 10 mm thick multi wall polycarbonate sheet roofing with following specification. The roofing made of 10mm thick multi wall polycarbonate sheet with approved colour (Lexan branded) double sided UV coated using MS frame work consists of main truss 50 x 50 mm MS square pipe for vertical support in the base plates and top connecting plate for fixing truss. The rate including cost of 10mm thick multi wall polycarbonate sheet, MS truss work, MS vertical support pillars, Horizontal purlins, Aluminium plate for bottom & top with sealent for all joint of sheets and labour charges for all fabrication works and sheet fixing work and necessary Scaffolding cost and painting work for all MS Truss with purlin etc., completed. and as directed by departmental officers.
289Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessorieswith6A Modular switchin flush with Modular MS box and covered with modular plates and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (5 points per coil)
290Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessorieswith6A Modular switchin flush with Modular MS box and covered with modular plates and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (6 points per coil)
291Wiring with 3 x 1.5 sq.mm PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories and with MS moduler box with 2nos 6A Two way module switch covered with module front plate inflush with wall and making good of the concealed portion with suitable colour for PVC concealed and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point
292Supply and fixing of 4 feet SBT fitting with 20 W LED tube (single side) on wall or ceiling with round blocks with PVC unsheathed copper leads from terminals to the fitting with proper connections complete
293Supply and fixing of 4 feet 20W single box type fitting complete with Twin conduit pipe suspension from ceiling with connecting PVC unsheathed copper leads from terminal to the fitting complete
294Supply and fixing of2x224W LED recess mountedLuminaries fitting with conduit /chain suspension and with PVC unsheathed copper leads from terminal to the fitting with necessary connection.
295Supply and fixing of 120W LED streetlight fitting on GI pipe of 32mm Dia with suitable clamps on wall with interconnection complete
296Supply and fixing of 200W LED flood light fitting on suitable angle iron or pillar frame work on wall/elevations with interconnection complete.
297Supply and fixing of BH 10W with intergrated fitting with integrated LED driver and connecting with PVC unsheathed copper leads from terminals to the fitting
298Supply and fixing of 1200mm (48”) Sweep AC ceiling fan (High speed) complete with stepped electronic 100W regulator with 300mm down rod on and including fixing of new clamp on ceiling complete
299Supply and fixing of 450 mm wall mounting fan with necessary connection.
300Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
301Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan
302Supply and fixing of 450 mm (18") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
303Supply and fixing of louvers shutters arrangements for 450 mm (18") sweep (light duty) AC exhaust fan
304Supply and fixing of 1no.6A two module socket , 1 no. 6/16A two module socket, 1 no. 6A one module switch, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections.
305Supply and fixing of 3nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections.
306Supply and fixing of 2 modular box with 1 no 25A modularsocket with one 25A DP MCB in 2 pole enclosure in flush with wall with earth connection.(AC plugset)
307Supply and fixing of 63A 4P MCB with enclosure in flush with the wall with earth connection
308Supply and fixing of 32A 4P MCB with enclosure in flush with the wall with earth connection
309Supply and fixing of 32A 2P MCB with enclosure in flush with the wall with earth connection (For various Stores)
310Supply and fixing of 12 way SPMCB Distribution board with metal double door with IP 42, IK-07 Protection in flush with wall with 1No 32 Amps DP MCB as incoming and 10 Nos 10Amps SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB"s should be with ISI mark (SLDB and Lift supply)
311Supply and fixing of7Segement three phase distribution boardwith 4 way triple pole MCB distribution board with metal double door with IP 42, IK-07 protection, with 63A 4 pole MCB as incoming and 3 Nos 63A DPMCB, 12 Nos 6-32A SPMCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark.
312Supply and fixing of Vertical type 12 way triple pole neutral MCB distribution board metal double door with IP 42, IK-07 Protection, with 125A 4 pole MCCB as incoming and 2 Nos 32A TPMCB, 2 Nos 63A TP MCBand 24 Nos 6A to 32A SPMCBas Outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark.
313Supply and run of 2 of 4 sqmm (56/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 Sq.mm Cu wire and making good of the concealed portion with suitable colour
314Supply and run of 2 of 6 sqmm (84/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 Sq.mm Cu wire and making good of the concealed portion with suitable colour
315Supply and Run of 4 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
316Supply and run of 4 of 10 Sqmm (140/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 Sq.mm Cu wire and making good of the concealed portion with suitable colour
317Supply and run of 4 of 16 Sqmm PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 Sq.mm Cu wire and making good of the concealed portion with suitable colour
318Supply and Erection of 400A capacity dust and vermin proof cubical panel boardmade up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting switcheswith centre bus chamber andvertical covers, cable chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in I.S specifications INCOMER 400A 4P MCCB -2 Nos with interlocking arranagement of only one incommer on at any given time by means of one key two switching operation
319OUTGOING 200A TP MCCB - 4 Nos 160A TP MCCB - 1 Nos 100A TP MCCB-2 NosThe bus bar chamber with consist of 4 Nos 2” x 1/4” tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans .2Nos 1/8” tinned copper flats should be provided all round the panel of earth bus. The fuse switches should be connected with the phase and neutral buses with suitable size of rigid copper flat/rod with suitable lugs phase and neutral tinned buses should be tinned properly
320The panel should be powder coat paint of approved colourapproved by the site officer and also the danger board. The capacity of the switches size of incoming and out going cable the place to which the supply is fed should be mounted on switch chamber. The panel board should be mounted on 100mmx 50mmx MS channel provided all around the bottom of the panel. The whole arrangement should be erection of a angle iron frame pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 1.0 m from the ground level and with necessary earth connection(Floor AC, Essential plugs panel)
321Supply and Erection of 250A capacity dust and vermin proof cubical panel boardmade up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting switcheswith centre bus chamber andvertical covers, cable chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in I.S specifications. INCOMER 250A 4P MCCB -2 Nos with interlocking arranagement of only one incommer on at any given time by means of one key two switching operation OUTGOING 100A TP MCCB -4 Nos 63A TP MCCB-1 No
322The bus bar chamber with consist of 4Nos 1” x 1/4” tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans .2Nos 1/8” tinned copper flats should be provided all round the panel of earth bus. The fuse switches should be connected with the phase and neutral buses with suitable size of rigid copper flat/rod with suitable lugs phase and neutral tinned buses should be tinned properly
323The panel should be powder coat paint of approved colourapproved by the site officer and also the danger board. The capacity of the switches size of incoming and out going cable the place to which the supply is fed should be mounted on switch chamber. The panel board should be mounted on 100mmx 50mmx MS channel provided all around the bottom of the panel. The whole arrangement should be erection of a angle iron frame pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 1.0 m from the ground level and with necessary earth connection(Floor Lighting Panel)
324Design, supply erection testing commissioning and handing over 150KVAR capacity automatic power factor control panel with 150KVAR capacitors with the following specifications L&T etasys-MU contactor switched standard AFC panel/Equivalent capacitors –LTXI ultra heavy duty capacitors. In comer-400A MCCB switching –Auto+ manual 1)Automatic Power factor controller Power factor controller for 150KVAR capacitor bank indigenously designed micro controller based programmable controller works three phase and switchingon the suitable capacitor banks and maintaining the PF to the Optimum. The controller is to have a scrolling LCD display which shows instantaneous voltage and current of all the three phases KW, KVA, KVAR and PF indication for the number of banks ON/OFF load in balance and protection for low/High voltage single phasing and phase sequence.
3252) Supply and fixing of suitable power supply unit for the power factor controller3)Supply and fixing of current voltage Transducers of ratio 400:1 to measure current and voltage in all the three phases 4) Supply and fixing of suitable current limiters to cater the inrush current.5)Supply and fixing of 400A MCCB as incoming to the panel 6)Supply and fixing of suitable MCCB’s for switching ON andOFF of 1 to VIII stage wise capacitors of the capacitor.7)Supply and fixing of contactors of suitable rating for switching ON & OFF of the capacitors in various stage of L&T Make/Equivalent8)Supply and fixing of 150 KVAR capacitor 440V, 50HZ Dleta connected L&T LT/L Ultra heavy duty capacitors Make/ equivalent in 6 Stages in steps.Stage wise details1)Stage : 12.5KVAR 2)Stage: 12.5KVAR 3)Stage: 25.0 KVAR 4)Stage: 25.0KVAR 5)Stage: 25.0KVAR 6)Stage : 50.0KVAR
326Design, Supply, testing and commissioning of 800A floor mountedMV cubical panel bus bar chamber dust and vermin proofaccommodating the following switches and 1 No800A ACB as Incomer unit with the following items of work complete to satisfy the latest IS rules and CEIG guidelines. Supply and fixing of suitable size bus bar chamber made up of 16 SWG MS sheet steel with 4 Nos of 2” x ½” tinned copper bus bar for 3 phases and neutral and 2nos of earthing bus of size 1” x 1/8 tinned copper bus on suitable bus bar insulator (Epoxy insulator) with maximum creep age distance and supported on MS base channel frame work of size 4”x2”x 1”-1set incoming
327safety access+D99+D97series as per CEIG,IE rules in force with inter connection and terminations as required in specification 2)Supply and fixing630A TPMCCB( Make L&T/Siemens) - 2 Nos Interconnecting the all LTSwitches to bus bar withsuitable insulated tinned copper flats and painting of phases and neutral indication Doubleearth connection of the switches to earth bus using suitabletinned copper flatsby 2 runs of 1” x 1/8” supply and fixingof LED lamp arrangements with toggle switches to the control to each phaseand with rigid connection in suitable separate compartments with 2 sets of supply and fixing of Trivector meter L&T or equivalent make in the cubicle by CEIG rules with supply and fixing of danger board with Siemens grey powder coating with super scribing the names of places to which supply is fed feeder sizes of cables direction of cables etc., Erection of panel board complete with suitable foundation bolts and nuts including suitable MS channel concrete, testing and commisioning.
328Supply and laying of run of 3 of 3 ½x400 sqmm PVC LTUG armoured cable in HDPE pipe of suitable dia in a trench to be excavated at depth of 0.75m and refilling the earth to make good (SD 756 Rs.2440 x 3 runs = Rs.7320) (T/F Outgoing)
329Supply and fixing of brass cable gland for 3-1/2 x 400 sqmm PVC armoured LTUG cable with earth connection
330Supply and providing cable end termination of 3-1/2 X 240 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
331Supply and laying of run of2 of 3 ½x185 sqmm PVC LTUG armoured cable in HDPE pipe of suitable dia in a trench to be excavated at depth of 0.75m and refilling the earth to make good (SD 753=1432*2=2864) (For 600 A power, light Raising Mains, DG, AMFs and C/o panel)
332Supply and clamping of Run of2 of 3-½x185 sqmm PVC armouredLTUG cable on wall with earth connection
333Supply and clamping of Run of3-½x185 sqmm PVC armouredLTUG cable on wall with earth connection
334Supply and fixing of brass cable gland for 3-1/2 x 185 sqmm PVC armoured LTUG cable with earth connection
335Supply and providing cable end termination of 3-1/2 X 185 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
336Supply and clamping of 3-1/2 X 150 sqmm PVC armoured LTUG cable on post or on wall with MS clamps (for lighting panel, AC Panel on floor)
337Supply and fixing of brass cable gland for 3-1/2 x 150 sqmm PVC armoured LTUG cable with earth connection
338Supply and providing cable end termination of 3-1/2 X 150 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
339Supply and Laying of 3 1/2 x 120 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good ( for motor room)
340Supply and fixing of brass cable gland for 3-1/2 x 120 sqmm PVC armoured LTUG cable with earth connection
341Supply and providing cable end termination of 3-1/2 X 120 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
342Supply and Laying of 3 1/2 x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
343Supply and fixing of brass cable gland for 3-1/2 x 70 sqmm PVC armoured LTUG cable with earth connection
344Supply and providing cable end termination of 3-1/2 X 70 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
345Supply and Laying of 3 1/2 x 50 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
346Supply and fixing of brass cable gland for 3-1/2 x 50 sqmm PVC armoured LTUG cable with earth connection
347Supply and providing cable end termination of 3-1/2 X 50 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
348Supply and clamping of 3-1/2 X 35 sqmm PVC armoured LTUG cable on post or on wall with MS clamps(for lift room)
349Supply and fixing of brass cable gland for 3-1/2 x 35 sqmm PVC armoured LTUG cable with earth connection
350Supply and providing cable end termination of 3-1/2 X 35 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
351Earthingas per ISI specification with an earth electrode of 2.1mtr class ‘B” GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mmx6mm with necessary funneling arrangement with necessary masonry work with 38 mm RCC cover slab for brick masonry works.(For Transformer, DG, MV panel, CSSD, Laundry,Lift, Raising Mains, RMG)
352Supply and run of25mm x 3mm tinned copper flat with necessary clamps/support on wall / floor/ground for earth connection
353Supply and run ofNo 8 SWG GI Wire for earth connection
354Supply, Erection, Testing and commissioning of 1 No 26 Persons bed cum Passengers lift, Gearless lift with machine roomas per the specification which Excluded tax and duties. Technical Specifications: Type of Lift: Bed Cum Passenger . Capacity of Lift:26 Persons(1768 Kgs) 1) Speed:1.0mtr/sec 2) Type of Drive: Microprocessor based Specific Variable voltage Variable Frequency (V3F) drive with enhanced ride comfort, and near Zero Levelling functions. 3) No. of. Floor: Ground + 6 floors 4) Total Travel: 21 mts Servicing Ground + 6 floor stops, 7 levels & opening 5) Levelling Accuracy : High Level Accuracy with smooth & Jerk free stopping 6) Construction of car: Special car made up of stainless steel moonrock finish panels complete with false ceiling in car sleek (small circular lights) tubular handrail, fan for better aesthetic.
3557) Position of Machine: Directly above the Lift Well. 8) No. of Car entrance: Side/centre opening door with stainless steel No.4 finish complete with SS frames. 9) No. of Landing Entrance-Side/centre opening door with stainless steel No.4 finish complete withSS frame. 10) No. of entrance: One in front only 11) Car size: 2400mm wide x 1300mm Deep x2000mm height, clear opening: 1100mm x 2000mm height. 12) Lift Well size:2300mm wide x 3000mmDeep.RCC Construction with Brick masonry 13) Lift pit depth: 1600mm 14) Power supply: 415V Three phase and 230V 50HZ single phase AC supply for light. 15) Control: Micro computer based full collective logic system with /without attendant mode. 16) Car Indicator: Digital 7segment 1.1mm Height direction & position indicator with height intensity indication in Red colour. 17) Landing indicator: Digital 7segment 25mm height direction & position indicator with height intensity indication in Red/orange colour.
35618) Emergency alarm bell: Battery operated alarm bell to be provided with automatic charging. 19) Emergency light: Battery operated light to be provided with automatic charging device 20) Fire man’s switch: To be provided at Ground floor 21) Minor builders work: To be provided by Lift contractor 22) Scaffolding: To be provided by lift contractor 23) Steel for lift Machinery; To be provided by lift contractor 24) Stainless steel sill angles and facial plates. To be provided by lift contractor 25) Servicing and Maintenance: Free Comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 26) Automatic Rescue Device: To facilitate the landing of the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, inverter, under voltage protection system etc. 27) Overload indicator for no of passengers/aggregate load exceeding the set limit
35728)Floor annunciate with music a) Inverter based battery operated emergency light& alarm bell. b) Stainless steel signal fixtures c) Aluminium checker plate flooring d) Call Registering Type Braille micro push button e) Automatic rescue device f) Full collective logic g) PCB control push button h) Separate fan switch in the car i) Constant voltage Transformer for control system j) In built brake release lever k) Pit ladder l) Load weighing device m) Lift floor announcement n) Minor civil works o) Scaffolding
35829)Over speed governor, phase failure and phase reversal relay, alarm bell, T guide brackets for car and counter weight, Rubber padding under winding unit. Motor of adequate capacity, single reduction worm gear electromagnetic brake withcompression springs, car safety gears, buffers, electro mechanical door locks. Emergency key. Side supporting angels motor over load protection devices, final limit switch main suspensions ropes, counter weights, etc., 30) Guarantee: Guarantee for the materials and workman ship of equipments complete should be offered by the lift firm for a period of not less than one year. 31) Site testing in accordance with IS 14665 should be carried out at the time of handing over.32) All the feature as per differently abled persons act should be provided 33) 2 hrs fire retardant landing doors
359Supply, Erection, Testing, Commissioning and Handing over of 1 No 500 KVA Diesel Generator set (Make: Kirloskar/ Ashok Leyland/ Equivalent) of 0.8P.f. Three Phase, 415/420Volts, 50c/s, 1500 RPM as detailed below 1.ENGINE: Water cooled Diesel engine suitable for generator application with a shaft Output of 670 BHP at 1500 RPM under NTP Condition as per BSS 5514/IS 10000. The engine shall comprise the following standard scope of supply: 1. Dry type Air cleaner 2. Expansion bellow 3. Radiator, Radiator fan and mounting 4. Air to air charge cooler 5. Exhaust Gas turbo charger 6. Lube oil cooler and Lube oil filter 7. Fuel filter (pre and micro) 8. In-line Mono-block fuel injection pump with governor and fuel feed pump 9. Electronic governor 10. 24V Battery charging alternator 11. 24V Volt electric starter motor 12. Engine test Certificate 13. Residential Mufler 14. Fly Wheel with starter ring, dynamo, standard batteries with cable, flexible exhaust piping.
360C) STANDARD CONTROL PANEL: The control panel (cubical) should be vermin and dust proof and fabricated with 16 SWG CRCA sheet metal and floor mounted with suitable hinged doors, enamel painted & incorporating the following. 1No. KWH meter. 1No. Frequency meter 1No. Voltmeter selector switch. 1No. KW meter 1No. Ammeter selector switch with Ammeter. 1No. AC voltmeter. 3Nos. Current transformer with suitable ratio. 1Set of pilot lamps and push button switch for ON and OFF operation. 1Set input terminal board. 1Set output terminal board. 1No. MCB of suitable capacity with magnetic thermal overload release instantaneous short circuit trip under voltage release. 1Set of HRC fuses for back up protection. 1Set of fuses for the meters
3611No. power factor meter 1No. Battery charger for charging the battery from mains comprising of i)Transformer ii)Rectifier iii) DC ammeter iv)DC voltmeter v)charging rate selector switch vi)circuit breaker vii)voltage regulator. [Note: this will be in addition to the battery charging alternator fitted on the engine] 1Set of audio and visual indications arrangement for: i) Low lubrication oil pressure ii) Over speed iii) High water temperature 1no Isolator to isolate the neutral 1no “set on” indicating lamp and 1no “load on” indicating lamp 1no Earth fault relay Note: the engine shall trip for the following conditions 1) Low lubrication oil pressure 2) Over speed 3) High water temperature
3624. ACOUSTIC ENCLOSURE: Acoustic enclosure shall be powder coated and fabricated of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC Machine to maintain dimensional accuracy of hole within 0.1 mm Powder coating done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE RETARDANT 64 Kg/m density mineral wool of 100mm thickness as Acoustic material. Four hinged doors shall be provided to canopy. The average sound level at 1 Mt. distance shall be less than 75 DBA average or as per CPCB norms. Surface treatment-Painting: The enclosure surface shall be suitably treated for degreasing de-rusting and posphating. The canopies are passed through seven-tank treatment thoroughly. Additional features of canopies:
363Canopy fabricated on CNC machines with dimensional accuracy of 0.1 mm so as to increase its durability. Special designed supporting rips/Structures are used in canopies so as to give sturdiness and to reduce the vibration of the DG sets if any.
364World class Cooling package: Canopies shall have cooling package for which it can also perform at 45 degree C/ambient temperature. No grouting required on the ground, only a level surface capable ofwithstanding the DG weight. Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set. The Gen set frame shall also be provided with hooks for unloading. Temperature rise inside the canopy: Canopies shall be designed so asto maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well within 57 deg centigrade. 5. FUEL TANK:500 liters Removable fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connection and mechanical fuel gauge. Fuel tank can be easily removed for clearing or any maintenance. 6. BASE FRAME:The base should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled, with cross members mounted on AVM. The base frame shall be provision for the mounting of acoustic enclosure on it. The supply of generator set includes loading. Unloading and transportation charges.7. Battery: 2 Nos 12V 180 AHR Battery (DATA - A22) (Power DG)
365Supply and Installation of Exhaust Piping of Sufficient length with suitable MS pipes with necessary thermal insulations.
366Supply of lubricating oil and first charging of starting battery and supply of diesel to run the Gen set for minimum of 8 hours Diesel
367Supply and laying of 8 core 2.5 Sq. mm Cu cable for 250 kVA DG control with AMF panel
368Supply and fixing of 400A 3 phase 4 Pole Changeover switch with enclosure on wall with complete connection.(For EB bypass )
369Supply and fixing of 100A 3 phase TPN Switch SDF with enclosure on wall with complete connection.(Lift Main Switch)
370Indoor Five Panel Consumer VCB: Supply, erection, testing, commissioning and of 11KV 25KA HT FIVE panel Vacuum Circuit Breaker Switch, Indoor type forinstallation, board comprising one Incomer VCB and 4 Nos Outgoing 630A 500MVA VCB.1.Draw out type 11KV 500MVA 630A Horizontal Draw out/ Horizontal Iso+D108lation VCB operated with spring charged mechanism.Anti Pumping device ,110V DC Shunt Trip and closing Coils (DC source of supply to be derived from a Power pack suitable for 3 Tripping and Two closing operation counter, 4NO + 4NC spare Aux. Contact for customer use, Automatic safety D109shutter, Mechanical Close/ Trip knob, Mechanical ON/OFF indication, Operating Handle, 110V AC-D109110V DC Power Pack etc. (Incom-1 & Outgoing-4 Nos)Core(Core 1-15VA class 1 for metering and core 2-15VA 5P 10 for Protection) Incoming 1 No, Current Transformers of 30/5-5 Amps Dual Core (Core 1-15VA Class 1 for Metering and Core 2-15VA 5P 10 for Protection)(Outgoing-1) 4.Meters:2. 11KV/Root 3/ 110V/ Root3- Three Phase, 3 Limb 200VA Class 1 Resin Cast Draw out type Potential transformers complete with HT and LT HRC fuses. (Incoming-1 No)
371Digital Voltmeter with selector switch (Incoming 1 No) Digital Trivector of L&T/Secure make (Incom-1No) Digital Power Factor Meter (Incom-1 No) Digital Frquency Meter (Incom-1 No) 5. Protection: TP ND IDMT 2OC + 1EF Relay with Highest inst.Elements similar like Megawin type MCDG 61 (Incom-1No) 6. TP ND IDMT 2OC + 1 EF Relay similar like Megawin type MCDG 31 Master trip Relay Megawin MVAJH 13 (Incom-1No & Out-4 Nos) 7. Breaker ON/OFF/Auto Trip/Healthy/Spring Charged Indication Lamp LED Type 8. Phase Indication Lamps R,Y,B(Incomings 3Nos)9. Control Wiring10. 800Amps Copper Bus bar PVC Sleeved and required panel copper earthing. 11. Control switch TNC (Incoming-1 No, Outgoing -1No) 12.Trip Circuit healthy Push Button(Incoming-1 No, Outgoing -1No)13. Common for Switch gear, MCB"s for AC DC Control, Heater ON/OFF Switch with space Heater and thermostat Single phase switch socket, cubicle illumination lamp, Disconnecting type terminal Block.etc.,14. MS Sheet enclosure for Indoor Installations Powder.
372Supply and Laying of 3C x 300 Sq.mm. 11 KV HT XLPE cable in a suitable 6" duro pipe to be excavated at a depth of 1 metre and covering the cable completely and refiling the earth to make good.(Make Gloster/Havells/ Polycab)
373Supply and providing cable end termination suitable for 11KV 3 core 300 sq.mm XLPE HTUG cable with necessary indoor type heat / cold shrinkable joint kit and accessories (Make : Ray Chem. / M Seal)
374Supply, erection, testing and commissioning of 500 KVA/ 11KV / 433V off load tap changing copper wound indoor type distribution transformer conforming to relevant IS 1180 (LEVEL 2) standard and fitted with the following : a) HV side Cable end box for connecting 1R of 120 Sq.mm. HT XLPE Cable. b) LT side cable end box suitable for connecting 4 runs of 3 ½ x 400 sqmm LTUG cable c) Conservator with shut off valve &drain plug valve d) Dehydration silicagel1 breather e) Expansion vent f) 4 Nos. plain rollers g) Thermometer pocket with dial type thermometer with capillary tubing with maximum reading position h) Drain plug / valve with Filter valve i) Oil filling hole,cap &Oil level gauge j) Two body earthing terminals
375k) Rating and terminal marketing plate. l) Lifting hooks to facilitate movement of transformer m) OFF load hand operated tap changing switch n) Tap - HV winding voltage variation - 5% to + 5% o) Neutral on LV side to be available for 4 wire supply and brought out through bushing for earthing. p) Air release device q) Transformer to be supplied with first filling of oil. r) All removable covers shall be provided with weather proof hot oil resistant, resistant gaskets to prevent leakage of water into core oil from the tank (Make :CREL/Voltech/equivalent)
376Supply, Installing on wall or suspension on ceiling, testing and commissioning of following capacity air insulated compact type raising mains for use on 3 phase 4 wire 415 V, 50 Hz AC supply with enclosure having IP 54 rating after fixing the tap off boxes and all accessiories for 630A
377Supply, installing, testing and commissioning of following capacity TPN tap of box made of 1.6 mm thick sheet steel enclosure -400 A
378Supply, installing, testing and commissioning of following capacity TPN tap of box made of 1.6 mm thick sheet steel enclosure -250 A
379Preparation of Electrical schematic diagram, site plans, physical layout 5 copies and payment of CEIG fees, submission of completion report, rectification report, obtaining drawing approval,Permanentsafetycertification etc., for the building and the DG sets complete including Schematic diagram lamination copy fixed at DG room.
380Erection of Gen Set: Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation. Erection of 250 kVA generator set over the existing foundation and erection of generator set including supply and fixing Dunlop make Anti Vibration mounts to the generator set
381Supply, installation and testing of 4 pole End feed unit with 630A FP ACB on existing raising main complete
382Supply, erection, testing and commissioning and handing over of 5.5 TR nominal capacity ceiling suspended duct able Air conditioner with the following components for the power saving units..
383a)5.5 TR nominal capacity ceiling suspended packaged Duct-able Air Conditioner high tech, low height, low noise level Indoor unit with fin and tube type cooling coil, Detachable type drier provided in refrigerant circuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil with required valves, directly coupled blower to reduce troubles and wear & tear compared to belt driven blower, Thermostatic expansion valve lift and pull type aluminium framed durable, washable air filter, integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45o F suction temperature Auto reset type HP/LPsafety cut to improve reliability of compressor. Compressor Qty - 1 No Refrigerant R-22 Air Flow - 2200 CFM
384b) 5.5 TR nominal capacity ceiling suspended packaged ductable air conditioner high tech outdoor unit with condenser shall be made of super slit high efficient aluminium fins mechanically banded to copper tubes condenser "L" type coil to be rigidly fixed to unit frame with fasteners imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven by 3 phase motor with protection condensing temperature 130o F for the system operations. Mounting - Rubber Sleeve and nut Capacity - 5.5 TR
385Supply, erection, testing and commissioning of 11.0 TR nominal capacity ceiling suspended duct able Air conditioner unit with the following components. a) 11.0 TR suspended Duct-able Air Conditioner high tech, low height, low noise level Indoor unit with fin and tube type cooling coil, Detachable type drier provided in refrigerant circuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil with required valves, directly coupled blower to reduce troubles and wear & tear compared to belt driven blower, Thermostatic expansion valve lift and pull type aluminum framed durable, washable air filter, integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45o F suction temperature Auto reset type HP/LPsafety cut to improve reliability of compressor.Type - Ceiling suspended Blower Qty. - 2 nos. Motor – 1no Motor Power – 370W/single phase Weight – 91 KgAir Flow - 4400 CFM
386b) 11.0 TR capacity Floor Mounting duct able air conditioner high tech outdoor unit (2 x5.5 TR separate units) with power saving high efficiency sturdy and rugged 1 No. of scroll compressors each with inbuilt internal thermal protector internal pressure relief valve. Auto reset type HP / LP safety cut out to improve reliability of compressors and condenser shall be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser "L" type coil to be rigidly fixed to unit frame with fasteners imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven by 3 phase motor with single phase preventer protection condensing temperature 130o F for the system operations.Mounting - Rubber Sleeve and nut on floor Refrigerant - R22Speed – 2900Weight - 150 kgCapacity – 11.0 TR Consumption – 9.216 KW/each Type - Air cooled finned tube Face area - 13.3 sqft Tube dia - 3/8" Tube Thick – AluminumNo. of fan - 2 Nos. Fin density – 14 Fpi. RPM – 900Watts – 149/each(Make: Carrier/ Voltas /Bluestar /Equivalent)
387Floor Mounted AIR HANDLING UNITS WITH WEATHER PROOF (a) Supply, Installation,Testing and Commissioning of ceiling suspendd Double skin Air Handling Units of capacity 11TR constructed with 0.8mm pre-plasticized / Pre pre coated Galvanized sheet steel and 0.8mm galvanized sheet inside with 45(+/-)2 mm thick PUF ( Non CFC,of minimum density 40 kg/m3) sandwiched insulation panel complete with thermal break profile.AHU to comprise of various sections as described below sequentially in the direction of airflow. AHU to be mounted on anti vibration mounts and properly sized to accommodate various components: Note: 1) Fan Efficiencyshall be not less than 70% •Low Leakage extruded aluminum aerofoil opposed blade type fresh airdamper •Low Leakage extruded aluminum aerofoil opposed blade type Exhasut airdamper •Low Leakage extruded aluminum aerofoil opposed blade type return airdamper for manual operation (0 to 100 %). •Leak Proof Hinged service doors • 50mm thick factory assembled filter section as per specification • Leak Proof Hinged service door. •Pressure Measurement nozzles across filter •50 mm Thk, Washable Type, 90% efficiency @ 10 microns MERV 8 rating filters (As per IS7613, ASHRAE 52.1) •Type of filters : Pre-filters•Frame : Galvanized Sheet Steel - Powder Coated, Flange type •Sealant : PU Sealant.
388Note : • Air Face Velocities acrossfilters should not exceed 500fpm.• 18 guage SS-304 insulated (minimum 25 mm thick insulation (MOC of insulation shall be as per AHU manufacturer standard)) condensate tray with drain pipe • Leak proof Hinged service door/Removable Panel with handles. • 4 bend Mist Eliminator. •AHU shall have Inter oven DX cooling coil to avoid air By pass . The fin spacing shall be 12 fins per inch.Six rows of the cooling coil shall be selected in such a way to take care of required conditions in all seasons. Cooling coil shall be Two seection of ....TR Capacity coil and each section connected to...TRODU. Expansion valve should be Electronic Expansion type with control panel and wireless remote, etc Supply Air Fan Section •Statically and Dynamically balanced AMCA Certified DIDW centrifugal fan with Motor Pulley, Belt driven package . Fan housing with motor to be mounted on a common steel baseon anti vibration springs mounts.•Leak Proof Hinged service door.•Lamp, Limit Switch & Wiring . •Double Glazed inspection window made from polycarbonate material. Each glazing to be of minimum 6 mm thickness.•Low Leakage extruded aluminum aerofoil opposed blade type Bleed airdamper for manual operation (0 to 100 %). •Fan motors shall be energy efficient (IE-4) and shall be 415±10% volts, 50 cycles, three phase, totally enclosed fan-cooled class F, with IP-55 protection.
389Motors shall be especially designed for quiet operation and motor speed shall not exceed 1440 rpm for forward curved fan and 2900 rpm for backward curved fan. The Motor shall be suitable for VFD Operation.Fine Filter (F7) with Filter section Disposable Type, 95% efficiency MERV 13 Maximum operating temperature - 70ºCType of filters : Fine filters F7 Frame : Galvanized Sheet Steel - Powder Coated, Flange type Media : Glass Fiber Sealant : PU Sealant. Capacity : 3740 CFM @ 2.54 m/s IPD : 115Pa +/10 % FPD : 450Pa • Leak Proof Hinged service door. •Pressure Measurement nozzles across F-7 filter The Blower Static Pressure - 100 mm wc. Entering Dry Bulb Temperature = 24 °CEntering Wet Bulb Temperature = 18 °C Leaving Dry Bulb Temperature = 11.3 °C Leaving Wet Bulb Temperature = 11.5 °C The below Cfm should be achived at 85% of its Fan RPM. 11TR, 3740CFM
390(b) 11 TR nominal capacity ceiling suspended packaged ductable air conditioner high tech outdoor unit with condenser shall be made of super slit high efficient aluminium fins mechanically banded to copper tubes condenser "L" type coil to be rigidly fixed to unit frame with fasteners imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven by 3 phase motor with protection condensing temperature 130o F for the system operations. (Quotation enclosed) HP/LPsafety cut to improve reliability of compressor. Compressor Qty - 1 No Refrigerant R-410 Mounting - Rubber Sleeve and nut Capacity - 11 TR 11 TR nominal capacity ceiling suspended packaged ductable air conditioner high tech outdoor unit with condenser shall be made of super slit high efficient aluminium fins mechanically banded to copper tubes condenser "L" type coil to be rigidly fixed to unit frame with fasteners imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven by 3 phase motor with protection condensing temperature 130o F for the system operations. HP/LPsafety cut to improve reliability of compressor. Compressor Qty - 1 No Refrigerant R-410 Mounting - Rubber Sleeve and nut Capacity - 11 TR (SR)
391Supply & installation of Stainless Steel Plenum as per the Scheme with duct openings, UV Light in the Plenum and and with fine filter & perforated plates at the botttom for Terminal laminar flow for OT"s with 120fpm velocity 1200mm L x 1200 mm W x 400 mm H
392Supply & Fixing of Washable Type, 90% efficiency @ 10 microns MERV 8 rating prefilter at Retrun air duct Terminal 300 x 300 600 x 600
393Supply and laying of 1 3/8’’ hard drawn Copper pipe interconnecting indoor unit and condensing unit with necessary fittings, supports etc.
394Supply and laying of 1 1/8’’ hard drawn Copper pipe interconnecting indoor unit and condensing unit with necessary fittings, supports etc.
395Supply and laying of 7/8’’ hard drawn Copper pipe interconnecting indoor unit and condensing unit with necessary fittings, supports etc.
396Supply and providing of pipe line nitrle rubber insulation for suction line, refrigerant pipe and drain pipe
397Supply and fixing of Flexible Canvas Connection
398Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 22 Gauge thickness
399Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 24 Gauge thickness
400Supply & providing acoustic lining for initial portion of ducting with 12mm thick Fibre Glass Rigid Board covered with Tissue Paper and Aluminium Perforated Sheet.
401Supply and filling of R-410 Refrigerant gas
402Supply and fixing of extruded Aluminium powder coated, Supply and return Air Grilles diffusers with volume control damper
403Supply, fabrication and fixing of suitable MS angle frame for mounting the outdoor units for protection from the rainwater with dust flow on the open terrace / wall, ground floor area.
404Supply and fixing of water drain pipe line (1 inch PVC)
405Supply and providing thermal insulation of 9 mm thick vido flex with aluminum foil
406Supply and laying of 7 core 2.5 sq.mm flexible copper cable from indoor to outdoor unit
407Supply and fixing of duct mouth dampers.
408Supply and fixing of 50mm thick anti vibrating rubber pads
409Supply and installation of 2 TR capacity 3 star rated energy efficient Hi-wall mounting split type Air-conditioning unit consisting of outdoor condensing unit complete with hermetically sealed Air compressor with R22 refrigerant air cooled condenser, fan etc., and 1 number indoor unit comprising evaporator unit with cooling coil, blower motor and connected accessories, control etc., with copper refrigerant piping and cord wire connecting indoor and outdoor unit with drain pipesuitable for operation on 230V +/- 10% 50 Hz single phase A.C. supply adhering following norms a)  Nominal Cooling capacity -23300 BTU/Hr b)  Air flow rate-635CFM C)Noise level -48/40/32db
410Supply and laying of 5/8” and 3/8” copper pipe (beyond 3 mts length)
411Supply and fixing of MS stand for fixing out door unit
412GST at 18%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail