Tender For Construction Of Building For School Of Nursing In Government Stanley Hospital, Chennai-1., chennai-Tamil Nadu

Public Works Department-PWD has published Tender For Construction Of Building For School Of Nursing In Government Stanley Hospital, Chennai-1.. Submission Date for this Tender is 08-02-2024. Building Work Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42083533
Tender For Construction Of Building For School Of Nursing In Government Stanley Hospital, Chennai-1.
Open Tender
Indian
Tamil Nadu
chennai
08-02-2024

Tender Details

Construction Of Building For School Of Nursing In Government Stanley Hospital, Chennai-1.

Key Value

Document Fees
Refer document
EMD
INR 642500.0 /-
Tender Value
INR 12.64 Crore /-

BOQ Items

Name of Work :Construction of Building for School of Nursing in Government Stanley Hospital, Chennai-1.
Sl. No. Item Description
1Installation charges inclusive of transportation to site and the driven pile equipment employed for the works including setting of pile driving equipments with all accessories and tools of each of the pile location based on the sequence of operation approved by the departmental engineers irrespectiveof the location and distance involved in movement of pile driving equipment for all sizes of piles and dismantling the driven pile equipment etc., complete.
2Installation of Vertical Bored cast in situ RCC piles in all types of soils using Design Mix concrete of M30 grade with sulphate resisitant cement, fine aggregate, 20 mm and down graded HBGS jelly coarse aggregate. the rate included cost of reinforcing steel, binding wire, fabrication, welding charges, placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with bentonite solution with temperory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavation of mud pits for circul.ation Bentonite solution, closing the mud pits to origional level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456 - 2000. Acceptance criteria by clause 16.1. frequency of testing should be as per clause 15.2.2. the length of pile for payment shall be measured up to natural ground level. The work should be carried out as per IS 2911. Pile depth should be decided by the departmental office at site.
3600 mm dia pile having longitudinal main reinforcement of 8 Nos 20#with helical reinforcement at 8 # @ 150mm C/C with inner rings of 12 # @ 1000mm C/C with liftinghook of12 # at required length.
4Initial Load Test as per IS 2911 Part IV 1985 including cost of single pile (250% of pile capacity), labour, reinforcement charges and all other incidential charges including excavation, shoring, strutting, dewatering etc. as necessary hire charges for jacks, measuring devices, Structural Frame work for platform, Kent ledges etc, as required and providing pilecap.
5Routine load test as per IS 2911 part IV 1995 (150% of pile capacity) including labour charges for jack, measuring devices, structural frame work plot form, kent ledges etc., as required and as directed by the departmental officers etc. complete.
6Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification
7Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
8Supplying and filling in foundation, basement, etc with filling Crushed stone sand (M Sand) in layers of not more than 15cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
9Supplying and filling in foundation and basement with crushed stone dust in layers of not more than 15 cm thick, well rammed watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
10Brick work in Cement Mortar 1:6 mix (One CementSix M-Sand) using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.
11For Foundation and basement
12Brick work in Cement Mortar 1:6 mix (One Cement Six M-Sand) using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.
13For Superstructure in Ground Floor
14For Superstructure in First Floor
15For Superstructure in SecondFloor
16For Superstructure in Third Floor
17For Superstructure in Fourth Floor
18For Superstructure in FifthFloor
19Brick partition walls of 11.00cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
20In Ground Floor
21In First Floor
22In Second Floor.
23In Third Floor.
24In Fourth Floor
25Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
26Supplying and Erecting Centering for sides and sofits including supports and strutting upto 3.29 M height for plane surfaces such as RC floor slab, roof slab, rectangular, square tee or ell beams, lintels, staircase, waist slab, landing slab, landing beam, potico slab, portico beams in all floors with all cross bracings using mild steel sheets of size 90 cm x 60 cm and 10 gauge stiffened with welded mild steel angles of sizes 25 mm x 25 mm x 3 mm for boarding laid over silver oak joists size 10 x 6.50 cm spaced at about 90 cm centre to centre supported by casurina props 10 cm to 13 cm dia spaced at 75 cm centre to centre etc. complete compying with standard specification and as directed by the departmetal officers.
27Plane surface such as Rcc floor slab, roof,slab,rectangular,square Tee or Ell beam, lintel, bed block staircase waist slab, landing slab, landing beam, portico beam, portico slab, etc.
28For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
29For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
30Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/m? and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials).
31In Foundation and basement
32In Ground Floor
33In First Floor
34In Second Floor.
35In Third Floor.
36In Fourth Floor
37In Fifth Floor
38Supplying, fabricating and placing in position Mild steel or Ribbed Tor steel rods for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire)
39Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer
40Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
41Supplying and fixing in position best approved of BIS quality 110mm dia PVC rain water down fall pipes having a pressure of 4kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete
42160mm dia PVC Pipe
43Paving the floor with best quality Double Charged Vertified Tiles of size 600 x 600 x 8mmof approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
44Dadooing walls with following best approved quality with printed design colour glazed tiles of size 600 x 600 x 8mm set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
45Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
46Supplying and fixing Fully Solid Core WPC-75MMX50MM:Providing and Fixing of Qute WPC/PVC Solid Door frame extruded with size 75mmx50mm.The inner core made of rigid WPC Compound with minimum shore hardness of 55,and Bulk Density 0.8 Grms/Cub.C.mt.The frame shall be fixed fixed to the wall using 10x100mm long M.S.Screw through the frame by using PVC Fasteners.A minimum of 4nos screws to be provided for each vertical member
47Supplying and fixing Ornamental Teak Wood door of overall Size 6.00 x 3.00m with the door opening of 3.00 m & balanced portionfixed both side of shutter made of toughned glass having designed to elegant look .. FRAME : outer frame of well Seasoned Teak woodscantlings of size 8” x 6” with required carvings and rebates to suite the door shutter. .The Frame should be fixed in position with necessary anchorage such as heavy duty holdfasts by dismantling the R.C.C or stone Masonry and redoing the same to the original position withCement Concrete and adhesive material requiredfor the job so as to keep the frame in vertical position and true to the plumb. The frame should also be embedded into the floor by making necessary dismantling on the floor and redoing the same to its original position after placing the same.
48Solid core Flush shutters with teak ply on both side with teak wook lipping alround35 mm thick rebate cutting etc.,withas per IS 2002 part I of 1991 including labour charges for fixing all furniture fittings and specials. The flush shutter should be ISI specification and finished both side with melamine polished and got approved by the dept. officers before fixing.SS fittings of 6" tower bolt-1No, 4" tower bolt-1No, door stopper-1No, aldrop-1No,hinges 6"-3 Nos, 8"-ornamental handle of Satin finish and lock etc., complete complying with standard specification and as directed by the departmental officers. (melamine finish door)
49Double leaves
50Solid core Flush shutters with teak ply on both side with teak wook lipping alround35 mm thick rebate cutting etc.,withas per IS 2002 part I of 1991 including labour charges for fixing all furniture fittings and specials. The flush shutter should be ISI specification and finished both side with melamine polished and got approved by the dept. officers before fixing.SS fittings of 6" tower bolt-1No, 4" tower bolt-1No, door stopper-1No, aldrop-1No,hinges 6"-3 Nos, 8"-ornamental handle of Satin finish and lock etc., complete complying with standard specification and as directed by the departmental officers. (melamine finish door)
51Single Leaf
52Supplying and fixing of wood polymer composite (WPC) door with solid door frames extruded with size 75mmx50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55 and buld density 750kg/cub.Mt. The frame shall be fixed to the wall using 10x10mm long MS screw throught the frame by using PVC fasteners. A minimum of 4nos screw to be provided for each vertical members, Door Shutter of 25mm thick Wood Polymer Composite (WPC) single core Extruded Door Shutter, with one side digital printing of specified Design which is approved by engineering-in-charge. Both side of the shutter shall have rough sugar texture finish, laminated with UV oil. The solid WPC board shall have minimum shore hardness of 55 and Bulk density 550kg/cub.Mt moulding the thickness remains 25mm (+/-1mm) etc. complete as per the direction of the departmental officers.(make Qute / Equivalent)
53Suppling and fixing of UPVC Window Specification: SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profilethe size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
54Suppling and fixing of UPVC Ventilator Specification: SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
55Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
56Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mmfromfinishedfloorlevelweldedto38mmdia StainlessSteelpipepostof1.00mmthick asverticalat 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
57Plastering with Cement Mortar 1:5 (One cement and Five M-sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
58Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete
59Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., completecomplying with standard specification.
60Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc.,
61Supplying and fixing in position best quality and approved make Indian made White glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
62Supplying, laying and jointing UPVCPipes of approved quality and best variety of "B" class pipe of the following dia including labour fixing UPVCSpecials, (excluding charges for cutting and threading of pipes, cost of such specials) to wall with necessary teak wood plugs, clamps, screws, thread balls, shellac, etc., making holes on the walls (or) drilling holes in roof and making good the dismantled portions to original condition with necessray brick work / concrete and plastering wherever necessry with necessary scaffolding charges. The pipes are to be painted with the 2 coats of good variety and approved best quality of synthetic enamel paint over a priming coat of red oxide etc., complete in all floors complying with standard specification. UPVCshall be got approved by the Executive Engineer before use on works.
6340mm dia UPVC pipe
6432mm dia UPVC pipe
6525mm dia UPVC pipe
6620mm dia UPVC pipe
67Supplying and fixing in position the following UPVCSpecials of heavy type and approved quality and good variety excluding fixing charges but including necessary cutting and threading of UPVCpipes, jointing the UPVC specials and painting with two coats with good variety and best quality synthetic enamel paint over a coat of red oxide primer and jointing the specials with pipe line using shellac etc., complete complying with standard specification. (The UPVC specials should be got approved by the Executive Engineer concerned before use on works.)
6832mm dia upvc Union
6925 mm dia upvc Union
7020 mm dia upvc Union
7132mm dia upvc Elbow
7225mm dia upvc Elbow
7320mm dia upvc Elbow
7432mm dia upvc Tee
7525mm dia upvc Tee
7620mm dia upvc Tee
7732mm dia upvc Coupling
7825mm dia upvc Coupling
7920mm dia upvc Coupling
8032mm dia upvc Nipple
8125mm dia upvc Nipple
8220mm dia upvc Nipple
83Supplying and fixing in position the following UPVCSpecials of heavy type and approved quality and good variety excluding fixing charges but including necessary cutting and threading of UPVCpipes, jointing the UPVC specials and painting with two coats with good variety and best quality synthetic enamel paint over a coat of red oxide primer and jointing the specials with pipe line using shellac etc., complete complying with standard specification. (The UPVC specials should be got approved by the Executive Engineer concerned before use on works.)
8432x25mm dia upvc Reducer
8525x20mm dia upvc Reducer
8620x15mm dia upvc Reducer
8732x25mm dia upvc Reducer Tee
8825x20mm dia upvc Reducer Tee
8920x15mm dia upvc Reducer Tee
90Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work.
9132mm dia Gun Metal Gate Valve
9225mm dia Gun Metal Gate Valve
9320mm dia Gun Metal Gate Valve
94Supplying and fixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works)
95Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.
96Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works).
97Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
9875mm dia
99110mm dia
100Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
10175mm dia Elbow
102110mm dia Elbow
10375mm dia Elbow with Door
104110mm dia Elbow with Door
105Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
106Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mmdiaof1.60mmthickweldedtotherailing. The supports will be groutedinto the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supportingarrangementsthehandrailinfloor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete.
107Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
108Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessorieswith6A Modular switchin flush with Modular MS box and covered with modular plates and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (5 points per coil)
109Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessorieswith6A Modular switchin flush with Modular MS box and covered with modular plates and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (6 points per coil)
110Wiring with 3 x 1.5 sq.mm PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories and with MS moduler box with 2nos 6A Two way module switch covered with module front plate inflush with wall and making good of the concealed portion with suitable colour for PVC concealed and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point
111Supply and fixing of 4 feet SBT fitting with 20 W LED tube (single side) on wall or ceiling with round blocks with PVC unsheathed copper leads from terminals to the fitting with proper connections complete
112Supply and fixing of 4 feet 20W single box type fitting complete with Twin conduit pipe suspension from ceiling with connecting PVC unsheathed copper leads from terminal to the fitting complete
113Supply and fixing of2x224W LED recess mountedLuminaries fitting with conduit /chain suspension and with PVC unsheathed copper leads from terminal to the fitting with necessary connection.
114Supply and fixing of 120W LED streetlight fitting on GI pipe of 32mm Dia with suitable clamps on wall with interconnection complete
115Supply and fixing of BH 10W with intergrated fitting with integrated LED driver and connecting with PVC unsheathed copper leads from terminals to the fitting
116Supply and fixing of 1200mm (48”) Sweep AC ceiling fan (Crompton High speed) complete with stepped electronic 100W regulator with 300mm down rod on and including fixing of new clamp on ceiling complete
117Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
118Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan
119Supply and fixing of 450 mm (18") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
120Supply and fixing of louvers shutters arrangements for 450 mm (18") sweep (light duty) AC exhaust fan
121Supply and fixing of 1no.6A two module socket , 1 no. 6/16A two module socket, 1 no. 6A one module switch, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections.
122Supply and fixing of 3nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections.
123Supply and fixing of 2 modular box with 1 no 25A modularsocket with one 25A DP MCB in 2 pole enclosure in flush with wall with earth connection.(AC plugset)
124Supply and fixing of 63A 4P MCB with enclosure in flush with the wall with earth connection
125Supply and fixing of 12 way SPMCB Distribution board with metal double door with IP 42, IK-07 Protection in flush with wall with 1No 32 Amps DP MCB as incoming and 10 Nos 10Amps SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB"s should be with ISI mark ( MCB DB and MCBs are Legrand/Hager make)
126Supply and fixing of7Segement three phase distribution boardwith 4 way triple pole MCB distribution board with metal double door with IP 42, IK-07 protection, with 63A 4 pole MCB as incoming and 3 Nos 63A DPMCB, 12 Nos 6-32A SPMCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark.
127Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 3 nos. 32A 3P MCB, 18 nos.6A to 32A SP MCB as outgoing in flush with wall with earth connection only.. The MCB DB and MCB’s should be with ISI mark.
128Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
129Supply and run of 2 of 4 sqmm (56/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 Sq.mm Cu wire and making good of the concealed portion with suitable colour
130Supply and run of 2 of 6 sqmm (84/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 Sq.mm Cu wire and making good of the concealed portion with suitable colour
131Supply and run of 4 of 10 Sqmm (140/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 Sq.mm Cu wire and making good of the concealed portion with suitable colour
132Supply and Erection of 400A capacity dust and vermin proof cubical panel boardmade up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting switcheswith centre bus chamber andvertical covers, cable chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in I.S specifications. INCOMER 400A 4P MCCB -1 No OUTGOING 200A 4P MCCB - 07 Nos 100A 4P MCCB-02 NosThe bus bar chamber with consist of 4 Nos 2” x 1/4” tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans .2Nos 1/8” tinned copper flats should be provided all round the panel of earth bus. The fuse switches should be connected with the phase and neutral buses with suitable size of rigid copper flat/rod with suitable lugs phase and neutral tinned buses should be tinned properly
133The panel should be powder coat paint of approved colourapproved by the site officer and also the danger board. The capacity of the switches size of incoming and out going cable the place to which the supply is fed should be mounted on switch chamber. The panel board should be mounted on 100mmx 50mmx MS channel provided all around the bottom of the panel. The whole arrangement should be erection of a angle iron frame pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 1.0 m from the ground level and with necessary earth connection
134Supply and Erection of 200A capacity dust and vermin proof cubical panel boardmade up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting switcheswith centre bus chamber andvertical covers, cable chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in I.S specifications. INCOMER 200A 4P MCCB -1 No OUTGOING 100A TP MCCB -2 Nos 63A TP MCCB-1 No The bus bar chamber with consist of 4Nos 1” x 1/4” tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans .2Nos 1/8” tinned copper flats should be provided all round the panel of earth bus. The fuse switches should be connected with the phase and neutral buses with suitable size of rigid copper flat/rod with suitable lugs phase and neutral tinned buses should be tinned properly The panel should be powder coat paint of approved colourapproved by the site officer and also the danger board.
135The capacity of the switches size of incoming and out going cable the place to which the supply is fed should be mounted on switch chamber. The panel board should be mounted on 100mmx 50mmx MS channel provided all around the bottom of the panel. The whole arrangement should be erection of a angle iron frame pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 1.0 m from the ground level and with necessary earth connection
136Supply erection,testing and commissioning of LT/CT meter box of dust and vermin proof of size 48”x36”x12” made up of 16SWG CRCA sheet with confirming to IE rules specifications. 1).The metering box should be divided into three separate chambers for metering,C.T.bus and cable chambers 2) In metering chamber, necessary space should be provided to fixone number electronic tri vector meter and 1 number 14 terminal box for trivector meter 3) Bus chamber should be provided with 2“x1/2” copper flat for three phases and neutral.Buses should be mounted on suitable insulators with 3 numbers of 250/5A C.T.coil ( KAPPA/equi. Make) 4) The metering chamber should be provided with glazed inspection door arrangement.Indication lamp arrangement should be provided with suitable control push button switch in the door of meter chamber 5) The doors of all the three chambers should be earthed with flexible copper wire 6)The metering box arrangement should be erected on suitable MS channel arrangement 7) 1”x1/8” copper flat of 0.4 mt long used as earth bus and it should be fixed at one side of the lower portion with suitable number of earth bolts 8)The box should be painted with powder coated enamel paint 9)Neutral link should be provided in side the pillar box.
137Supply and Laying of 3 1/2 x 150 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
138Supply and fixing of brass cable gland for 3-1/2 x 150 sqmm PVC armoured LTUG cable with earth connection
139Supply and providing cable end termination of 3-1/2 X 150 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
140Supply and clamping of 3-1/2 X 120 sqmm PVC armoured LTUG cable on post or on wall with MS clamps
141Supply and fixing of brass cable gland for 3-1/2 x 120 sqmm PVC armoured LTUG cable with earth connection
142Supply and providing cable end termination of 3-1/2 X 120 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
143Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
144Supply and fixing of brass cable gland for 3-1/2 x 35 sqmm PVC armoured LTUG cable with earth connection
145Supply and providing cable end termination of 3-1/2 X 35 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
146Earthingas per ISI specification with an earth electrode of 2.1mtr class ‘B” GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mmx6mm with necessary funneling arrangement with necessary masonry work with 38 mm RCC cover slab for brick masonry works.
147Supply and run of25mm x 3mm tinned copper flat with necessary clamps/support on wall / floor/ground for earth connection
148Supply and run ofNo 8 SWG GI Wire for earth connection
149GST at 18%