Tender For Construction Work, chenani-Tamil Nadu

Public Works Department-PWD has published Tender For Construction Work. Submission Date for this Tender is 08-02-2024. Building Work Tenders in chenani Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42083095
Tender For Construction Work
Open Tender
Indian
Tamil Nadu
chenani
08-02-2024

Tender Details

Construction Work Construction Of Building For Nursing Hostel In Government Stanley Hospital, Chenani-1.

Key Value

Document Fees
Refer document
EMD
INR 1084200.0 /-
Tender Value
INR 21.48 Crore /-

BOQ Items

Name of Work : Construction of Building for Nursing Hostel in Government Stanley Hospital, Chenani-1.
Sl. No. Item Description
1Installation charges inclusive of transportation to site and the driven pile equipment employed for the works including setting of pile driving equipments with all accessories and tools of each of the pile location based on the sequence of operation approved by the departmental engineers irrespectiveof the location and distance involved in movement of pile driving equipment for all sizes of piles and dismantling the driven pile equipment etc., complete.
2Installation of Vertical Bored cast in situ RCC piles in all types of soils using Design Mix concrete of M30 grade with sulphate resisitant cement, fine aggregate, 20 mm and down graded HBGS jelly coarse aggregate. the rate included cost of reinforcing steel, binding wire, fabrication, welding charges, placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with bentonite solution with temperory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavation of mud pits for circul.ation Bentonite solution, closing the mud pits to origional level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456 - 2000. Acceptance criteria by clause 16.1. frequency of testing should be as per clause 15.2.2. the length of pile for payment shall be measured up to natural ground level. The work should be carried out as per IS 2911. Pile depth should be decided by the departmental office at site.
3600 mm dia pile having longitudinal main reinforcement of 8 Nos 20#with helical reinforcement at 10 # @ 200mm C/C with inner rings of 12 # @ 1000mm C/C with liftinghook of12 # at required length.
4450 mm dia pile having longitudinal main reinforcement of 8 Nos 16#with helical reinforcement at 8 # @ 150mm C/C with inner rings of 12 # @ 1000mm C/C with liftinghook of12 # at required length.
5Initial load test as per IS 2911 part IV 1995 (250% of pile capacitylabour , reinforcement charges and all other incidential charges including excavation, shoring, strutting dewatering etc., as necessary hire charges for jacks , measuring devices . structural frame work for plot form kent ledges etc., required and providing pile cap etc., complete as directed by the departmental officers
6Routine load test as per IS 2911 part IV 1995 (150% of pile capacity) including labour charges and all other incidental charges including hire charges for jacks , measuring devices , structural frame work for plot form,kent ledges etc., as required and as directed by the departmental officers etc., complete.
7Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
8Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete
9Supplying and filling in foundation, basement, etc with filling Crushed stone sand (M Sand) in layers of not more than 15cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
10Supplying and filling in foundation, basement, etc with filling stone dust (M Sand) in layers of not more than 15cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
11Brick work in Cement Mortar 1:5 mix (One CementFive M-Sand) using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.
12For Foundation and basement
13Brick work in Cement Mortar 1:6 mix (One Cement Six M-Sand) using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.
14For Superstructure in Ground Floor
15For Superstructure in First Floor
16For Superstructure in SecondFloor
17For Superstructure in Third Floor
18For Superstructure in Fourth Floor
19For Superstructure in Fifth Floor
20For Superstructure in SixthFloor
21For Superstructure in Seventh Floor
22Brick partition walls of 11.00cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
23For Superstructure in Ground Floor
24For Superstructure in First Floor
25For Superstructure in SecondFloor
26For Superstructure in Third Floor
27For Superstructure in Fourth Floor
28For Superstructure in Fifth Floor
29For Superstructure in SixthFloor
30Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
31Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
32For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
33For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
34For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
35Providing and laying in position, standardised concrete Mix M-30Grade in accordance using 20mm and down graded hard broken granite stone jelly for all RCC items of works withw mithin iImSu:4m5 6c-e2m00e0n,t content of 350 kg/ms and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, reta?d setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu"m") 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc.
36For Foundation and Basement
37For Superstructure in Ground Floor
38For Superstructure in First Floor
39For Superstructure in SecondFloor
40For Superstructure in ThirdFloor
41For Superstructure in Fourth Floor
42For Superstructure in Fifth Floor
43For Superstructure in Sixth Floor
44For Superstructure in SeventhFloor
45Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.
46Supplying and fixing in position best approved of BIS quality 160mm dia PVC rain water down fall pipes having a pressure of 4kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete
47160mm dia
48Supplying and fixing colour galvanum sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.
49Paving the floor with best quality Double Charged Vertified Tiles of size 600 x 600 x 8mmof approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
50Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
51Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes 600x600x8mm set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
52Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
53Providing Nosing for Granite Slab with machine and as directed by the Departmental officers.
54For Double Nosing
55Cladding the vertical wall surface with prepolished Granite slab of approved colour and quality of 20mm thick free from all defects and set in C.M. 1:2, 10mm thick joints shall be flush with face of granite slab and pointed neatly with same colour pigment etc., complete
56Supplying and fixing Fully Solid Core WPC-75MMX50MM:Providing and Fixing of Qute WPC/PVC Solid Door frame extruded with size 75mmx50mm.The inner core made of rigid WPC Compound with minimum shore hardness of 55,and Bulk Density 0.8 Grms/Cub.C.mt.The frame shall be fixed fixed to the wall using 10x100mm long M.S.Screw through the frame by using PVC Fasteners.A minimum of 4nos screws to be provided for each vertical member
57Supplying and fixing following ornamental Burma Teak wood entrance door as per the drawings and designs approved by the departmental officers. The size of the opening is 4.80m x 3.00m. The outer frame of the doors is 150mm x 125mm Teakwood. The main door shutter opening size is 3.00m x 2.40m. The each door shutter shall have 1/3rd paneled and 2/3rd glazed of 12mm thick plain toughened glass with ornamental designs. The door shutter outer frame of size 150x50mm. The door panels shall be of 50mm thick Teakwood planks with ornamental carving designs approved by the Executive Engineer. The lock rail shall be of 200x50mm thick teakwood frame. The top of the door at a height of 600mm finished with fixed glazing of approved pattern using 12mm thick toughened glass with M.S grill. The sides of doors shall be fixed glazing of size 900x2400mm finished with 12mm thick toughened designed glass. All the door frames and fixed glazing frames are made out of 150mm x 125mm teakwood of best quality. The door frames and shutters shall given two coats of best approved quality Malamine finish. The rate inclusive of cost of approved quality Teakwood, 12mm thick designed toughened glass, Brass hinges, Brass tower bolts, Brass aldrop, Door stopper, Brass screws, etc.. The cost includes cost of Materials, Labour charges, conveyance charges, Fixing charges, Carving charges and Glass design charges, Electricity charges and all other incidental charges etc.. All materials should be got approved by the Executive Engineer before use on works.
58Supplying and fixing solid core flush shutter 35mm thick with teak ply on both sides,teak lipping alround with necessary adhesive and C.P.screws, including fixing of aldrop , tower bolt, hinges , door stopper with Nylon bush and lock strike plates , putty, fevical etc., complete . All aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 for anodic film thickness of not less than 15 microns. The rate is inclusive of cost of fevical, fixing charges, polishing,transportation, loading, unloading all other incidental charges and handling charges etc., complete complying with standard specification.
59Single Leaf
60Supplying and fixing of wood polymer composite (WPC) door with solid door frames extruded with size 75mmx50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55 and buld density 750kg/cub.Mt. The frame shall be fixed to the wall using 10x10mm long MS screw throught the frame by using PVC fasteners. A minimum of 4nos screw to be provided for each vertical members, Door Shutter of 25mm thick Wood Polymer Composite (WPC) single core Extruded Door Shutter, with one side digital printing of specified Design which is approved by engineering-in-charge. Both side of the shutter shall have rough sugar texture finish, laminated with UV oil. The solid WPC board shall have minimum shore hardness of 55 and Bulk density 550kg/cub.Mt moulding the thickness remains 25mm (+/-1mm) etc. complete as per the direction of the departmental officers.(make Qute / Equivalent)
61Suppling and fixing of UPVC Window Specification: SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profilethe size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
62Suppling and fixing of UPVC Ventilator Specification: SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
63Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
64Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mmfromfinishedfloorlevelweldedto38mmdia StainlessSteelpipepostof1.00mmthick asverticalat 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
65Plastering with Cement Mortar 1:5 (One cement and Five M-sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
66Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M-Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc.,
67Plastering with Cement Mortar 1:3 (One cement and Three M-sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
68Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete
69Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., completecomplying with standard specification.
70Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc.,
71Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
72Supplying and fixing in position best quality and approved make Indian made White glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
73Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
74Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
75Supplying, laying and jointing CPVC pipes (Chlorinated Poly Vinyl Chloride) Pipe (Higher pressure rating with higher pipe thickness) Standard Dimension Ratio-11 of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. Internal Water supply
7620mm dia CPVC pipe
77Supplying, laying and jointing CPVC pipes (Chlorinated Poly Vinyl Chloride) Pipe (Higher pressure rating with higher pipe thickness) Standard Dimension Ratio-11 of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. Above ground level. (External Water Supply)
7832mm dia CPVC pipe
7925mm dia CPVC pipe
8020mm dia CPVC pipe
81Supplying, laying and jointing CPVC pipes (Chlorinated Poly Vinyl Chloride) Pipe (Higher pressure rating with higher pipe thickness) Standard Dimension Ratio-11 of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. Below ground level (External Water supply)
8232mm dia CPVC. Pipe
83Supplying CPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements Note: Since the labour for cutting, threading / pasting, sundries have already been included under pipe line item of works, no separate provision for fixing PVC specials needs to be allowed
8432mm dia CPVC Union
8525 mm dia CPVC Union
8620 mm dia CPVC Union
8732mm dia CPVC Elbow
8825mm dia CPVC Elbow
8920mm dia CPVC Elbow
9032mm dia CPVC Tee
9125mm dia CPVC Tee
9220mm dia CPVC Tee
9332mm dia CPVC Coupling
9425mm dia CPVC Coupling
9520mm dia CPVC Coupling
9632mm dia CPVC Nipple
9725mm dia CPVC Nipple
9820mm dia CPVC Nipple
99Supplying CPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements Note: Since the labour for cutting, threading / pasting, sundries have already been included under pipe line item of works, no separate provision for fixing PVC specials needs to be allowed
10032x25mm dia CPVC Reducer
10125x20mm dia CPVC Reducer
10220x15mm dia CPVC Reducer
10332x25mm dia CPVC Reducer Tee
10425x20mm dia CPVC Reducer Tee
10520x15mm dia CPVC Reducer Tee
106Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work.
10732mm dia Gun Metal Gate Valve
10825mm dia Gun Metal Gate Valve
10920mm dia Gun Metal Gate Valve
110Supplying and fixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works)
111Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.
112Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works).
113Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
11475mm dia
115110mm dia
116160mm dia
117Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
11875mm dia Elbow
119110mm dia Elbow
12075mm dia Elbow with Door
121110mm dia Elbow with Door
122Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
123Lime Concrete 1:2:5 (One lime, two sand and five brick jelly) using 40mm gauge brick jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor finish, curing etc. complete complying with standard specification. (For flooring in toilet partions except water closet portions).
124For Superstructure in First Floor
125For Superstructure in SecondFloor
126For Superstructure in ThirdFloor
127For Superstructure in Fourth Floor
128For Superstructure in Fifth Floor
129For Superstructure in Sixth Floor
130Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.
131Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessorieswith6A Modular switchin flush with Modular MS box and covered with modular plates and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (5 points per coil)
132Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessorieswith6A Modular switchin flush with Modular MS box and covered with modular plates and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (6 points per coil)
133Wiring with 3 x 1.5 sq.mm PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories and with MS moduler box with 2nos 6A Two way module switch covered with module front plate inflush with wall and making good of the concealed portion with suitable colour for PVC concealed and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point
134Supply and fixing of 4 feet SBT fitting with 20 W LED tube (single side) on wall or ceiling with round blocks with PVC unsheathed copper leads from terminals to the fitting with proper connections complete
135Supply and fixing of 4 feet 20W single box type fitting complete with Twin conduit pipe suspension from ceiling with connecting PVC unsheathed copper leads from terminal to the fitting complete
136Supply and fixing of2x224W LED recess mountedLuminaries fitting with conduit /chain suspension and with PVC unsheathed copper leads from terminal to the fitting with necessary connection.
137Supply and fixing of 120W LED streetlight fitting on GI pipe of 32mm Dia with suitable clamps on wall with interconnection complete
138Supply and fixing of BH 10W with intergrated fitting with integrated LED driver and connecting with PVC unsheathed copper leads from terminals to the fitting
139Supply and fixing of 1200mm (48”) Sweep AC ceiling fan (Crompton High speed) complete with stepped electronic 100W regulator with 300mm down rod on and including fixing of new clamp on ceiling complete
140Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
141Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan
142Supply and fixing of 450 mm (18") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
143Supply and fixing of louvers shutters arrangements for 450 mm (18") sweep (light duty) AC exhaust fan
144Supply and fixing of 1no.6A two module socket , 1 no. 6/16A two module socket, 1 no. 6A one module switch, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections.
145Supply and fixing of 3nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections.
146Supply and fixing of 2 modular box with 1 no 25A modularsocket with one 25A DP MCB in 2 pole enclosure in flush with wall with earth connection.(AC plugset)
147Supply and fixing of 63A 4P MCB with enclosure in flush with the wall with earth connection
148Supply and fixing of 12 way SPMCB Distribution board with metal double door with IP 42, IK-07 Protection in flush with wall with 1No 32 Amps DP MCB as incoming and 10 Nos 10Amps SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB"s should be with ISI mark ( MCB DB and MCBs are Legrand/Hager make)(SLDB and Lift supply)
149Supply and fixing of7Segement three phase distribution boardwith 4 way triple pole MCB distribution board with metal double door with IP 42, IK-07 protection, with 63A 4 pole MCB as incoming and 3 Nos 63A DPMCB, 12 Nos 6-32A SPMCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark.
150Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 3 nos. 32A 3P MCB, 18 nos.6A to 32A SP MCB as outgoing in flush with wall with earth connection only.. The MCB DB and MCB’s should be with ISI mark.
151Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
152Supply and run of 2 of 4 sqmm (56/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 Sq.mm Cu wire and making good of the concealed portion with suitable colour
153Supply and run of 2 of 6 sqmm (84/0.3)PVC insulated SC unsheathed Cu.conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 Sq.mm Cu wire and making good of the concealed portion with suitable colour
154Supply and run of 4 of 10 Sqmm (140/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 Sq.mm Cu wire and making good of the concealed portion with suitable colour
155Supply and Erection of 400A capacity dust and vermin proof cubical panel boardmade up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting switcheswith centre bus chamber andvertical covers, cable chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in I.S specifications. INCOMER 400A 4P MCCB -1 No OUTGOING 200A 4P MCCB - 08 Nos 100A 4P MCCB-02 NosThe bus bar chamber with consist of 4 Nos 2” x 1/4” tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE rules.
156This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans .2Nos 1/8” tinned copper flats should be provided all round the panel of earth bus. The fuse switches should be connected with the phase and neutral buses with suitable size of rigid copper flat/rod with suitable lugs phase and neutral tinned buses should be tinned properly The panel should be powder coat paint of approved colourapproved by the site officer and also the danger board. The capacity of the switches size of incoming and out going cable the place to which the supply is fed should be mounted on switch chamber. The panel board should be mounted on 100mmx 50mmx MS channel provided all around the bottom of the panel. The whole arrangement should be erection of a angle iron frame pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 1.0 m from the ground level and with necessary earth connection (EB Incommer Panel)
157Supply and Erection of 200A capacity dust and vermin proof cubical panel boardmade up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting switcheswith centre bus chamber andvertical covers, cable chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in I.S specifications.
158INCOMER 160A 4P MCCB -1 No OUTGOING 100A TP MCCB -2 Nos 63A TP MCCB-1 No The bus bar chamber with consist of 4Nos 1” x 1/4” tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans .2Nos 1/8” tinned copper flats should be provided all round the panel of earth bus. The fuse switches should be connected with the phase and neutral buses with suitable size of rigid copper flat/rod with suitable lugs phase and neutral tinned buses should be tinned properly
159The panel should be powder coat paint of approved colourapproved by the site officer and also the danger board. The capacity of the switches size of incoming and out going cable the place to which the supply is fed should be mounted on switch chamber. The panel board should be mounted on 100mmx 50mmx MS channel provided all around the bottom of the panel. The whole arrangement should be erection of a angle iron frame pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 1.0 m from the ground level and with necessary earth connection(Floor Panel)
160Supply erection,testing and commissioning of LT/CT meter box of dust and vermin proof of size 48”x36”x12” made up of 16SWG CRCA sheet with confirming to IE rules specifications. 1).The metering box should be divided into three separate chambers for metering,C.T.bus and cable chambers 2) In metering chamber, necessary space should be provided to fixone number electronic tri vector meter and 1 number 14 terminal box for trivector meter 3) Bus chamber should be provided with 2“x1/2” copper flat for three phases and neutral.Buses should be mounted on suitable insulators with 3 numbers of 250/5A C.T.coil ( KAPPA/equi. Make) 4) The metering chamber should be provided with glazed inspection door arrangement.Indication lamp arrangement should be provided with suitable control push button switch in the door of meter chamber 5) The doors of all the three chambers should be earthed with flexible copper wire 6)The metering box arrangement should be erected on suitable MS channel arrangement 7) 1”x1/8” copper flat of 0.4 mt long used as earth bus and it should be fixed at one side of the lower portion with suitable number of earth bolts 8)The box should be painted with powder coated enamel paint 9)Neutral link should be provided in side the pillar box. (EB Incoming panel)
161Supply and Laying of 3 1/2 x 150 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (for EB Incoming)
162Supply and fixing of brass cable gland for 3-1/2 x 150 sqmm PVC armoured LTUG cable with earth connection
163Supply and providing cable end termination of 3-1/2 X 150 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
164Supply and clamping of 3-1/2 X 120 sqmm PVC armoured LTUG cable on post or on wall with MS clamps ( for each floor panel)
165Supply and fixing of brass cable gland for 3-1/2 x 120 sqmm PVC armoured LTUG cable with earth connection
166Supply and providing cable end termination of 3-1/2 X 120 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
167Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (for lifts, pumps room)
168Supply and fixing of brass cable gland for 3-1/2 x 35 sqmm PVC armoured LTUG cable with earth connection
169Supply and providing cable end termination of 3-1/2 X 35 Sqmm PVC LTUG Alu.armoured cable with necessary alu.cable sockets by crimping etc with electrical connection complete
170Earthingas per ISI specification with an earth electrode of 2.1mtr class ‘B” GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mmx6mm with necessary funneling arrangement with necessary masonry work with 38 mm RCC cover slab for brick masonry works.(For Main panel, Each floor panel)
171Supply and run of25mm x 3mm tinned copper flat with necessary clamps/support on wall / floor/ground for earth connection
172Supply and run ofNo 8 SWG GI Wire for earth connection
173Supply, Erection, Testing and commissioning of 1 No 10 Persons Passengers lift, Gearless lift with machine roomas per the specification which Excluded tax and duties. Technical Specifications: Type of Lift: Passenger . Capacity of Lift:10 Persons(884 Kgs) 1) Speed:1.0mtr/sec 2) Type of Drive: Microprocessor based Specific Variable voltage Variable Frequency (V3F) drive with enhanced ride comfort, and near Zero Levelling functions. 3) No. of. Floor: Ground + 6 floors 4) Total Travel: 21 mts Servicing Ground + 6 floor stops, 7 levels & opening 5) Levelling Accuracy : High Level Accuracy with smooth & Jerk free stopping 6) Construction of car: Special car made up of stainless steel moonrock finish panels complete with false ceiling in car sleek (small circular lights) tubular handrail, fan for better aesthetic.
1747) Position of Machine: Directly above the Lift Well. 8) No. of Car entrance: Side/centre opening door with stainless steel No.4 finish complete with SS frames. 9) No. of Landing Entrance-Side/centre opening door with stainless steel No.4 finish complete withSS frame. 10) No. of entrance: One in front only 11) Car size: 1300mm wide x 1350mm Deep x2000mm height, clear opening: 1100mm x 2000mm height. 12) Lift Well size:1900mm wide x 2100mmDeep.RCC Construction with Brick masonry 13) Lift pit depth: 1500mm 14) Power supply: 415V Three phase and 230V 50HZ single phase AC supply for light.
17515) Control: Micro computer based full collective logic system with /without attendant mode. 16) Car Indicator: Digital 7segment 1.1mm Height direction & position indicator with height intensity indication in Red colour. 17) Landing indicator: Digital 7segment 25mm height direction & position indicator with height intensity indication in Red/orange colour. 18) Emergency alarm bell: Battery operated alarm bell to be provided with automatic charging. 19) Emergency light: Battery operated light to be provided with automatic charging device 20) Fire man’s switch: To be provided at Ground floor 21) Minor builders work: To be provided by Lift contractor 22) Scaffolding: To be provided by lift contractor 23) Steel for lift Machinery; To be provided by lift contractor 24) Stainless steel sill angles and facial plates. To be provided by lift contractor 25) Servicing and Maintenance: Free Comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 26) Automatic Rescue Device: To facilitate the landing of the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, inverter, under voltage protection system etc. 27) Overload indicator for no of passengers/aggregate load exceeding the set limit
17628)Floor annunciate with music a) Inverter based battery operated emergency light& alarm bell. b) Stainless steel signal fixtures c) Aluminium checker plate flooring d) Call Registering Type Braille micro push button e) Automatic rescue device f) Full collective logic g) PCB control push button h) Separate fan switch in the car i) Constant voltage Transformer for control system j) In built brake release lever k) Pit ladder l) Load weighing device m) Lift floor announcement n) Minor civil works o) Scaffolding
17729)Over speed governor, phase failure and phase reversal relay, alarm bell, T guide brackets for car and counter weight, Rubber padding under winding unit. Motor of adequate capacity, single reduction worm gear electromagnetic brake withcompression springs, car safety gears, buffers, electro mechanical door locks. Emergency key. Side supporting angels motor over load protection devices, final limit switch main suspensions ropes, counter weights, etc., 30) Guarantee: Guarantee for the materials and workman ship of equipments complete should be offered by the lift firm for a period of not less than one year to run at 1500 RPM under NTP conditionsconfirming to BS 5000/IS 13364 (part-II) 1992 to be coupled directly to the Diesel engine and test certificate
178Supply and fixing of 100A 3 phase TPN Switch SDF with enclosure on wall with complete connection.(Lift Main Switch)
179TNEB Connection charges for new LT connection complete
180GST at 18%
Disclaimer :