Tender For Addn/Altn Alonghwith Repair Of Perimeter Security Lights, Cable And Pole Along Nh Including Provn Of Mcb Distr Boxes And Bus Bars And Connected Items In Mh At Akhnoor And Provn Of 15 Kva Dg Set For Fsd Sunderbani Mil Stn Under Ge (N) Akhno, sunderbani-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Addn/Altn Alonghwith Repair Of Perimeter Security Lights, Cable And Pole Along Nh Including Provn Of Mcb Distr Boxes And Bus Bars And Connected Items In Mh At Akhnoor And Provn Of 15 Kva Dg Set For Fsd Sunderbani Mil Stn Under Ge (N) Akhno. Submission Date for this Tender is 05-03-2024. Busbar Tenders in sunderbani Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

42067774
Corrigendum : Tender For Addn/Altn Alonghwith Repair Of Perimeter Security Lights, Cable And Pole Along Nh Including Provn Of Mcb Distr Boxes And Bus Bars And Connected Items In Mh At Akhnoor And Provn Of 15 Kva Dg Set For Fsd Sunderbani Mil Stn Under Ge (N) Akhno
Open Tender
Indian
Jammu And Kashmir
sunderbani
05-03-2024

Tender Details

Addn/Altn Alonghwith Repair Of Perimeter Security Lights, Cable And Pole Along Nh Including Provn Of Mcb Distr Boxes And Bus Bars And Connected Items In Mh At Akhnoor And Provn Of 15 Kva Dg Set For Fsd Sunderbani Mil Stn Under Ge (N) Akhnoor

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 91000.0 /-
Tender Value
INR 45.50 Lakhs /-

BOQ Items

Name of Work : ADDN/ALTN ALONGHWITH REPAIR OF PERIMETER SECURITY LIGHTS, CABLE AND POLE ALONG NH INCLUDING PROVN OF MCB DISTR BOXES AND BUS BARS AND CONNECTED ITEMS IN MH AT AKHNOOR AND PROVN OF 15 KVA DG SET FOR FSD SUNDERBANI MIL STN UNDER GE (N) AKHNOOR
Sl. No. Item Description
1Supply, installation, testing and commissioning of silent diesel engine driven generating set developing suitable BHP water cooled of capacity 15KVA (12 KW), 415 Volts, 0.8 power factor , mounted on common base frame coupled, 1500 RPM, with silencer pipe protected with asbestos rope independently supported from engine to outside of power house up to 1.00 meter, AVM pads, foundation as per manifacture"s design, battery start with suitable cable for connectionfrom DG Set to panel boardcomplete with acoustic enclosure as per specification of pollution control board and including the following:- PRIME MOVER.Vertical diesel engine of suitable capacity having BHP water cooled, closed circuit as per BS-649 or IS-10002The DG set shall be capable of running 24 hrs continouslywith 10% overloading for one hour in every 12 hours as per BS-5514/BS-649. Engine shall be equipped with all standard fitting as per manufacture"srecomendations and mounted on common base frame with following fittings. RPM cum hour meter Battery charging ammeter V, I, Hz, Pf all as specified and directed. Ignition key and starting with push button switch. Lubrication oil pressure gauge. Mechanical Governor controlling.
2Oil temp. gauge Safety control (Trip) for the following:- Low lubricating oil pressure Over speed. Lub oil coolant heater to avoid freezing 12 volts starting equipment compresing of all followings:- 01 No 12 volts 75 AH battery. Make:Exide /standard/Amaron Battery charging alternator with inbuilt regulator Starter motor of suitable capacity . Battery leads (copper cable) of suitable size with terminal. Make of engine: Kirloskar/ Cummins/ crompton Greaves Ltd. ALTERNATOR:- Alternator rating 20KVA (16 KW), 3 phase, 50 cycles 415 Volt, 4 wire supply at0.8 power factor running @1500 RPM, self excited self regulated, mountedon a strong fabricated steel frame, suitable for mounting on a permanent foundation to be coupled with engine. The alternator shall be conforming to BS-2613 or IS-4722. Make of Alternator: Kirloskar/ Cummins/crompton Greaves Ltd. CONTROL AMF PANEL:- Alternator control panel floor mounted cubical type with internal copper wiring for 15 KVA alternator, 415 volts, 3 phase 4 wire, 50 cycles fabricated outof 1.6mm thick MS Steel, painted externally with two coats of synthetic enamel paintover one coat of primer including following accessories:- suitable scale flush mounted AC voltmeter with selector switch 0-500 volts : 1 set
3Suitable scale flush mounted ammeter with selector switch and CT"sof suitable range : 1 set frequency meter: 01 No KWH meter: 01 No MCCB Suitable range- 01 No. (forincoming) as recommmended by manufacturer . Copper cable of suitable capacity. OTHER FITTINGS :- Fuel Tank :MS fuel tank of suitable capacity as per manufacture"s instructions capable to store fuelfor 12 hours running of DG set including oil level indicating guage, drain & air vent plug etc.
4Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 1100 volts grade, 3.5 core, cross sectional area 50 Sqmm, all as specified and directed.
5Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation laying poles, stay assembly and laying of LT/HT cables in any type of soil and getting out, complete all as specified and directed.
6Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
7Removal of excavated material(soil) to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
8Supply and laying sub class "B" bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and as directed.
9Sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be recorded for payment putpose..
10On load change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps side handle, complete all as specified and directed.
11Supply and fixingAerial bunched cable (AB) LT of size 3 core- x16 sqmm+1-core x 16sqmm + 1x25 sqmmfor street lights. The 16 sq.mm. phase conductor shall be of aluminium solid round; outer diameter shall be within the limits.• The phase conductor shall be insulated with black weather resistant high-densitypolyethylene (HDPE) suitable to 1100 V insulation. The insulated conductors shall generally conform to the relevant standards.• Conductors: The properties of the aluminium wires before stranding shall be:• Tensile strength not less than 90 N/Sq.mm.• Resistivity at 20 Deg. C not exceeding 0.02845ohm / Sq.mm / m(V) and one bare messenger wire shall be stranded non compacted circular aluminium alloy conductor including taking down complete all as specified and directed. Make Havells, Gloster,Polycab,KEI Note:- The following hardware fittings and accessories shall be used to install,erect and join the AB cable (i) Suspension clamp with eye hook (ii) Suspension fittings and corresponding eye hook (iii) Dead eye fittinngs (iv) Nylon Tie (v) connectors
12Taking down old unsv burnt cable of any description & providing multistranded copper cable single coresize 1.5 sqmmrequired for street light connection, complete all as specified and directed.
13Material and labour for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45cm x 45cm x 45 cm, RCC cover 1:2:4 type B1 of size 45x45x6 cm reinforecd with 6mm dia mild steel bar @ 100mm c/c, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. Note:-The required resistance of Earthing shall be less than 3 ohm, If not found to the required resisstance, the contractor has to re earthingfor required resistance andthe cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.
14Supply and fixing in replacementof dusk level sensor switch for the networking of street light panel to Automatic control and energy saving of street light havingController( station 1 - 3) The Panel shall be Wall mounted / Floor Mounted , made out of 2 mm CRCA sheet totally enclosed dust and vermin proof with openable shutter / door in the front side, outdoor type and properly powder coatedwith IP 65 protection consisting of timer based on LDR sensor 3 Nos single phase AC contactor for each phase, 6nos MCB SP "C" curved 63 Amp for incoming & outgoing, selector switch for system to operate on manual & auto, alternate light control ssystem complete wiring including incoming and outgoing terminal port, including PC accessories Cat No ATSSLCSP100 of dvepl or equivalent in sasa/tricolite/ASPL. The firm specified can"t authorised any other vender to manufacture panel on their behalf. Original Panel manufacture panel are accepeted. The PLCsystem shall perform the following functions:
15Data overide by sms facility that work as per sunrise or sunset trigger or as per twilight with astro control longitude & latitude based.along with lux controller
16Parameters can be set remotely using SMS queries- like Output mode, Offset Hrs, UV, OV settings• Can remotely override relay output using SMS query Energy Meter Functionality Parameter like Load current, Supply voltage, Power, Energy can be known remotely • With the help of “Auto Error Code Update” onsite error can be retrieved remotely during output event
17Manual mode operation of entire System evenincase of availibility of single phase present in the system.
18Having tripping on over & under voltage, Over Load, dead Phase faults. These faults send to the operator and alert the operator to override the system.
19Auto/Auto on/Auto off As per user defined program settings, Instant ON up to next Auto Event and Instant OFF up to next Auto Event.
20Tiny Onboard Indication for TX-RX, Network, Power Indication and kwh pulse.
21Surge Suppressor to protect the PLC Modules form Harmful spikes and lightning.
22Supply voltage – 110-240 vac, 50/60Hz, 160-240 vac 3Phase 4 wire { P-N }, 50/60Hz, supply variation – 20% to +15%, Storage Temperature -10 C to+60C, Operating Temperature – 10C to + 50C, Switching Contacts – 9 No, 8A { resistive load } @ 240 VAC and 5A { resistive, load } @ 30 VDC, Power reserve { for clock only } 1000h, Clock deviation - ± s1 per day over the operating temperature range, DST – settable, EMI / EMC Radio Interference Suppression – CISPR 14-1 Class B, ESD – IEC 61000-4-2 Level III, Electrical Fast Transients, IEC 61000-4-4 Level IV, Surges – IEC 61000-4-5 Level IV, Voltage Dips & Interruptions – IEC 61000-4-11 All 7 Levels.
23Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sectionsincluding nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shapeor size as indicated or directed andinclusive of one primer coat, oneunder coat and one finishing coat of paint complete all as specified and directed.
24Steel tubular swaged pole type 410 SP-31 (9 metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5m from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5m from ground level/coping and also write the pole No on the surface of pole, complete all as specified and directed.
25Plain Cement Concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete of poles complete all as specified and directed.
26Cement concrete type C-1 1:3:6 (20mm graded crushed stone aggregate) as in copings of poles and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified and directed.
27Dismantling of old unsv PCC poles any size incl taking out embeded portion in PCCand making good disturbed ground complete all as specified and directed.
28Taking out LT cable ofsize16 Sqmm 4corefrom trenches/wall/poles and setting aside for re- use of serviceable cable, complete all as specified and directed.
29Re-laying of old serviceable cable as obtained from item No-18 above as in trenches, or fixed to wall/poles, complete all as specified and directed.
30Taking down old unsvHPSV/CFL/LED security lights fittings including GI brackets from external security poles complete all as specified and directed.
31Supply installation testing commissioning of 70 watt LED flood light built in die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lightingcomplete with all accessories pre wired and making connection with copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:-JETAALBAFLOODLIGHT70W or Equivalent cat part of make as specified in Appx "F" here in after.
32Supply, installation, connecting electrically and testing of street light junction box size 450x250x300mm, pole mounted made out of CRCA sheet 2 mm thick, powder coated having door with magnetic lock complete with bus bar 4 Nos suitable for 3 phase 4 wire supply system, made of aluminium strip of size 20x3mm including fixing arrangement made of MS Clamps of requisite size nuts, bolts and washers complete all as specified and directed.
33Supply, fabrication and fixing feeder pillar box of size 500x450x500mm made out of MS sheet of 315mm thick bent to shape & size factory made with welding, bending works suitable for and including 200 Amps rated aluminium bus bar (length of bus bar not less than 40 cm) 4 Nos, making holes of any size and mounted on porcelain/epoxy based post insulators of appropriate size with suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and lenght of angle iron not less than 1 mtr, 0.5 mtr to be embeded in PCC below G.L and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping,from one of the makes as specified in the List of makes enclosed at Appx "A" complete all as specified and directed.
34Supply laying and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 25 sqmm 3.5 core complete all as specified and directed.
35Supply laying and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 16 sqmm 4 core complete all as specified and directed.
36GI pipe light grade 50 mm bore for cable protection fixed on poleswith fixing clamps, nuts & boltsor laid in trenches/ floor/ passing through ducts etc complete all as specified and directed.
37Sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drwan through and including rigid PVC conduit of size 25mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexibe, PVC insulated, unsheathed, multistranded, 1100 volts grade, FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note: Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
38Supply installation testing commissioning of 80 watt LED flood light built in die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lightingcomplete with all accessories pre wired and making connection with copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:-JETAALBAFLOODLIGHT80W or Equivalent cat part of make as specified in Appx "F" here in after.
39DWC HDPE tubing 25mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclussived in quoted rate.
40DWC HDPE tubing 40mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclussived in quoted rate.
41DWC HDPE tubing 50mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclussived in quoted rate.
42MMS heavy duty PVC rigid pipe of size 25 mm having thickness 2mm thick (ISI marked) fix to walls or lay on floor for cable protection, complete all as specified and directed.
43MMS heavy duty PVC rigid pipe of size 40 mm having thickness 2mm thick (ISI marked) fix to walls or lay on floor for cable protection, complete all as specified and directed.
44Vertical distribution board TPN4 ways (IP-43) with built in bus bars, neutral links, blanking plates double door suitable for FP MCCB as incommer and out going SP/TP MCBs, complete all as specified and directed. Make:- Havells cat part No-DHDLVDRWGOFO04 or Equivalent cat part of make of Legrand / Indoasian / L&T
45Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 12 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, including blanking plates where required., complete all as specified. Make:-Havells cat part No-DHDPSHODPW12 or Equivalent cat part of make of Legrand / Indoasian / L&T
46Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 08 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, including blanking plates where required., complete all as specified. Make:-Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make of Legrand / Indoasian / L&T
47Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 04 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, including blanking plates where required., complete all as specified. Make:-Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make of Legrand / Indoasian / L&T
48MCCB 63 Amps, 4 Pole, 415 Volts, 50 Hz, 16 KA, adjustable thermal & fixed magnetic, complete all as specified and directed. Make:-Havells cat part No-IHDA3BBF0063 or equivalent cat part of make-Legran / INDOASIAN / L&T
49MCBsingle pole 6 to 32 amps 240 volts 10 KA "C" series, complete all as specified. Make:-Havells cat part No-DHMGCSPF006-032 or equivalent cat part of make-Legran / INDOASIAN / L&T
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail