| 1 | Earth work excavation for foundation in all kinds of soils and sub soils to full depth as directed by the departmental officers except hard rockinclusive of shoring strutting and balling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick well rammed and consolidated and depositing the surplus earth with in the compound in places shown by the departmental officers with initial lead of 10 meters and initial lift of 2 meters including cost of all labour charges etc., complete as per standard specification 23 & 24VI (S2) VII.9,10 Footings (First 2m depth) |
| 2 | Footings (3m depth) |
| 3 | Grade beam |
| 4 | Supplying and filling in foundation and basement with filling M-sand in layers of not more than 15 cm thick well watered rammed and con-solidated etc., complying with standard specifications |
| 5 | Plain Cement concrete 1 : 4 : 8 (one cement, four sand and eight aggregates) using 20mm and 40mm of 1/3 Part and 2/3 Part respectively ISS HBG metal including cost and conveyance of all materials and labour charges for mixing, laying, compactingand curing etc, complete as per SS |
| 6 | Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. Below GL from 1.5m to 4.5m depth |
| 7 | Above GL upto 4.5m height |
| 8 | Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc. Centering for soffits of RCC slabs plain surface including strutting upto 3.29 meter height using mild steel of size 90 cm x 60 cm x 10 gauge with MS angles of size 25 mm x 2 mm x 3 mm laid over silver oak (CW) joists of size 10 cm x 6 cm spaced upto 90 cm c/c and supported casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specification and as directed by the departmental officerFooting & Grade beam |
| 9 | Column |
| 10 | Roof Beam & Slabs |
| 11 | Supplying, fabricating and placing in position of Steel Reinforcement using Mild steel or Ribbed tor steel rods, for all RCC worksas per the design given by the departmental officers including cost of steel and binding wire and all labour charges for cutting, bending, tying and placing in position etc, complete as per SS. |
| 12 | Brick work In CM 1:5 mix using best country bricks of size 8 3/4 x 4 1/4 x 2 3/4\" having 350kg/cm2 compressive strength and 15% or less water absorbentin the period of 24hours immersement and confirming toISI specifications.and using the screenedsandand all the materials should be approved by the competent technical authorities etc complete complying with standard specification Ground floor |
| 13 | First floor |
| 14 | Scond floor |
| 15 | Brick Partition Walls using II class ground moulded chamber bricks of size 9\"X43/8\"X 23/4\"in C.M 1:3 (One part of Cement and Three part of Crushed Stone Sand (M- Sand))using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm Ground floor |
| 16 | First floor |
| 17 | Scond floor |
| 18 | Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 19 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement |
| 20 | Dadooing walls withGlazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 21 | Plastering with cement mortar 1:5 (One cement and Five sand) 12mm thick in all floors including cost and conveyance of all materials to site etc,complete as per standard specifications |
| 22 | Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 23 | Painting external wall with two coats of bestapproved quality of Plastice Emultion Paint over a including One Coat ofpriming of Exterior Emulsion Paint - Water Based Primer (Liquid) primier over cementsurface wall as dirceted by the departmental officersincluding cleaning preparing the surface etc,complete complying with standard specification.The cement paint should be got approved by the departmental officers before use on work . Exterior |
| 24 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being 32 : 12.5 well beated with wooden beaters for giving required slope and thickness 80mm as directed by the departmental officers etc., complete. |
| 25 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 26 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricatedfrom un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. M-0673-8313.00 |
| 27 | UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDMrubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work M-0674-7482.00 |
| 28 | UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride)Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 29 | FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers |
| 30 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 31 | Supplying and laying in flooringwith fully polished Sinthetic Grey colour Granite stone of 20mm thick (average) of 4\" X 2\" in size laid over base layer of cementmortar 1:3 (one cement and three Plastering sand) - 20 mm thick and applying cement slurry &pointed with white cement and colour pigments to the colour of stones and polished neatly as directed by the deparmental officers |
| 32 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for open PVC light point / fan point (for electronic regulator) Electrical |
| 33 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150mm x 100mm x 113mm TW switch box in flush with wall with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC plug point |
| 34 | Supply and fixing of 4\"40W twin box type fluorescent fitting complete with copper choke and condensor with TW round block on wall or ceiling with tubes and PVC unsheathed copper leads from terminal to the fitting with fluoresent tubes |
| 35 | 4 way / 8 way / 12 way vertical SPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single phase MCB outgoings and separate 2 way provision for accommodating One No. 2 pole incoming MCB / Isolator and another separate 2 way provision for accommodating One No. 2 pole ELCB / RCD with label holder and provisions for taking up cable for size not less than 35 sq.mm |
| 36 | Supply and fixng of TNEB meter board suitable for 3 phase 100A service connection made up of suitable angle ironframe work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2\" x 1-1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V), 1 No. neutral link, copper earth flat of size 1\" x 1/4\" with interconnection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete |
| 37 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class \"B\" GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 38 | Supply, delivery, erection, testing and commisioning of 45 KVA capacity Deisel generator set 3 phase, 50 Hz, 415 V, consisting of deisel engine capable of delivering continuous brake horse power with standard fittings, water cooled radiators acoustic closure restrict the noise level as per KPCB norms, residential silencer with exhaust pipe arrangements (insulated with glass wool inside the building) upto outside of the room above roof level suitable alternaor (brushes) self excited, self regulator suiltable for continuous operation. Standard control panel, consisting of ameter with CTC and selected switch with volt meter with selector switch, LPCB energimeter, earth fault relay, indicating lamps, fuses and required 1.1 KV grade PVC Armoured aluminium cable from alternaor to alternaor control panel, 12/24 V battery, battery leads, battery charges etc., coupling with guard fuel tank (8 hrs capacity) common rigid MS Channel base frame, anti vibration mounting pad, etc., complete with sychronised panel including all accessories items etc complete as per standard specifications(AMF) (PWD SOR 2022-23 P.No:45 Item No :9(i)) |
| 39 | BED-CUM-PASSENGER LIFTS (G+3)SS 304 Grade with 1m/sec. speed with ARD Higher End |
| 40 | Supply and Fixing of CCTV Camera with Specification of Dahua- HAC-HFW 1100DP-B-0600 720P 1 Mega Pixel AnalogHigh Definition camera, outdoor-25/30 fps@720P,1/2.9\" 1 Megapixel CMOS, 50m IR,ICR, 6mm Lens optional, IR Bullet Dahua - Channel - AHD, High Video Quality on HD 1080N, Transmit Video Signal, audio signal & Dual way data communication signal over one coaxial cable, HD Video transmission without Video quality loss & delay, extremely, long transmission distance (300), as directed by Departmental Executive Engineer. Supply and Installing sony CCTVcameraLMR |
| 41 | 29\" Led TV for display LMR |
| 42 | Poe suitable for CCTV IP camera 24 port |
| 43 | Rack With Accesssories - 12U Rack |
| 44 | Armoured LAN & CCTV Cable Cat 6 |
| 45 | Hard Disk For NVR(8TB) |
| 46 | Network Video Recorder for CCTV 16 Channel |
| 47 | Internal Water Supply & Sanitary arrangement - P.V.C. Pipes (10Kg/SqCm & 6 kg/sqcm) Supplying laying and jointing P.V.C pipes (10Kg/SqCm & 6 kg/sqcm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessaryscaffolding charges.50mm dia pipe |
| 48 | 25mm dia pipe |
| 49 | 20mm dia pipe |
| 50 | 110mm dia |
| 51 | 75mm dia Pipe |
| 52 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \"U\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
| 53 | PVC Specials 25x20mm reducer |
| 54 | PVC Elbow 90mm dia |
| 55 | 110mm dia |
| 56 | PVC Tee 110mm dia |
| 57 | 90mm dia |
| 58 | Supplying and fixing in position first quality and approved variety of Gun Metal Gate Valve (Heavy type ) with I.S.I.mark of the following sizes including cost of Shellac , thread etc,.including labour for cutting and threading of PVC Pipes etc.,complete complying with standard specifications for both internal and external water Supply arrangements. Inlet Valve - 32mm Dia |
| 59 | 25mm dia |
| 60 | Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting |
| 61 | S/F in position of Indian Make White/Colour glazed earthen ware lipped mouth Flat Back Urinal of best approved quality with G.I.Pipe connection to suitable length,32mm bell mouthed P.V.C connection ,15mm dia G.M.Wheel valve,fixing the urinal to the wall in position with necessary T.W.plugs ,clamps,screws, shellac etc.,including dismantling masonry if necessary and redoing the same to original condition ,fixing the 15mm dia. G.I.pipe connection and wheel valve ,painting the pipe with two coats of approved paint over one coat of primer and checked without any leakage complete, complying with standard specifications. (The urinal Should be got app-roved by the Executive Engineer before use on works.) |
| 62 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with \"P\" trap or \"S\" trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 63 | Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications (the wash hand basins and specials should be got approved by the Executive Engineer before use on works). |
| 64 | Supplying and fixing of PVC Screw Down Tap Heavy Type 20mm dia etc., complete as per standard specifications |
| 65 | Supplying and erecting SINTEX or approved equivalent make HDPE plastic vertical cylindrical 5000 Litre Water Storage Tank. Strickly adhering ISI Standard as per ISI Mark 12701 (Latest revision) including all taxes and freight charges within Corpn.City limit etc complete as per stanadard specifications |
| 66 | Supply and fixing of PVC. Nahini / Floor Trap with stainless Steel Gratings - 100 mm x 75 mm including all charges etc, complete as per standard specification. |
| 67 | Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT M-0852 |
| 68 | Supply and fixing of Stainless Steel Solid waste Garbage bin of size 1.00 m height and 0.30m dia |
| 69 | Providing rain water harvesting using 3 No.of RCC well rings of 90cm inner dia (clear) with 5cm wall thickness made out of cement concrete 1:2:4 using 20mm hard broken jelly to a height of 30cm each supplying and fabricating 16 No. of 6mm dia MS rod vertically and 3 No. of 6mm dia MS rod circumferentially tied together with 18 guage binding wire for well rings including necessary earth work excavation 1m dia toa depth of 1m, supplying and filling 40mm HBG inside the erected well ring to a depth of 90cm, and top covered with RCC circular perforated cover slab of 1m dia and 5cm thick which inclusive of cost and fabrication of 6mm M.S reinforcement at 15 cm spacings on both directions and one 6mm M.S rod ties at the edge of the slab circumferentially including cost of moulding, curing, finishing and well placing in position and disposing off excavated earth with all initial leads and lifts in places as shown by the Departmental officers etc., complete in all respects. |
| 70 | Conducting Geophysical survey to find out the water table including cost for convey the instrument to the site and other charges |
| 71 | Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another within Tamilnadu in alluvial soil sedimentary strata of clay and sandstone shale pebbles boulders etc . By first taking a pilot bore of 140mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel ,labour and drilling bentonite and waterrequired for drilling at site (site will be shown by the concerned officers) including construction of mud pit0.00 to 50.00 M |
| 72 | 50.00 to 80 .00 M |
| 73 | b) Reaming from 150mm dia pilot bore as directed by the departmental officers upto 50m depth ending from ground level. 0.00 to 50.00 M |
| 74 | 50.00 to 80 .00 M |
| 75 | Supply of unplasticied PVC ribbed screen casing pipe and plain casing for borewells in 3M length screened and threated socket ends with couplers as per IS 12828/89 to suit deep borewells. a)150 mm casing Pipe For Upto 80m depth pipe assembly (with slot). |
| 76 | b)150mm CM For Upto 80m depth pipe assembly |
| 77 | c)150mm dia end cap Bore Well Cover. |
| 78 | MS 32/40mm MS clamp set |
| 79 | 50mm dia GM Non return valve |
| 80 | Nylon Rope for borewell |
| 81 | Labour charges for inserting PVC casing pipes assembly (with and without slot) in the drilled hole including jointing the pipeswith cement paste complete and packing annualar space with pebbles of size and quality as approved by the departmental officers. |
| 82 | Charges for developing Borewell with air compressor of 300CFM (100/150 PSI) capacity (minimum 8.00 hours ) including transportation , labour and fuel charges for compressor as directed by the concerned departmental officersetc complete and also conducting by V notch method |
| 83 | Supply anddelivery of Single phase Submersible pumpset Duty 20 lpm, 125m Head with ISI making for motor without panel board should conform to IS 8034/89 and AS ended from time to time .The pumpset should be supplied with 5M of flat sub.copper cable and all other necssaries etc. complete as per std,specifications |
| 84 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 230 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). |
| 85 | Labour charges for the erection of submersible pumpset in borewell / openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilotindicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. |
| 86 | HDPE PIPES - PE 100 AS PER IS 4984/2016(Pre-Compounded Resin) |
| 87 | Supply and delivery of PVC insulated and sheathed three core 2.5 Sq.mm Flat type copper cable conforming to IS 694/1990. Complete. |