}

Supply, Installation, Testing And Commissioning Of Air Conditioning System With Allied E.I. Work At Molecular Lab (Department Biochemistry) At Academic Building Of The Calcutta National Medical College, Kolkata, kolkata-West Bengal

Public Works Department has published Supply, Installation, Testing And Commissioning Of Air Conditioning System With Allied E.I. Work At Molecular Lab (Department Biochemistry) At Academic Building Of The Calcutta National Medical College, Kolkata. Submission Date for this Tender is 15-02-2024. Screws Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42008907
Supply, Installation, Testing And Commissioning Of Air Conditioning System With Allied E.I. Work At Molecular Lab (Department Biochemistry) At Academic Building Of The Calcutta National Medical College, Kolkata
Open Tender
Indian
West Bengal
Kolkata
15-02-2024

Tender Details

Supply, Installation, Testing And Commissioning Of Air Conditioning System With Allied E.I. Work At Molecular Lab ( Department Biochemistry ) At Academic Building Of The Calcutta National Medical College, Kolkata=2 Supply Of5 Tr Capacity Concealed Type Split Air Conditioner Having Rated Cooling Capacity Of 60000 Btu / Hr. With 02 Nos Twin Rotary Compressor , 2 Nos Iduof Rated Power Supply 230V-1Ph-50 Hz, 1 No Odu Of Rated Power Supply- 415 V, ± 5%, 50 Hz. Three Phase Ac Supply.Air Flow / Per Idu-1000Cfm ( Make Hitachi / O-General / Daikin / Voltas ) R410 Eco Friendly Refrigerent. 3 Erection And Commissioning Charges For The Above Mentioned 5.0 Ton Concealed Type Split Air Conditioner . Incl Charges For Hanging Arangments By 6 Mm Thick M.S U Channel. 4 Installation And Commissioning Of Copper Refrigerant Piping, Complete With Fitting, Elbows, Bends, Supporting Arrangement On Walls For Liquid Line 3 / 8 Od With .7Mm Thick. ( Make;Ryoku ) 5 Installation And Commissioning Of Copper Refrigerant Piping, Complete With Fitting, Elbows, Bends, Supporting Arrangement Onwalls For Suction Line 5 / 8 Od With .7Mm Thick. ( Make;Ryoku ) 6 Supply & Fixing Pipe Insulation In Liquid Line 3 / 8 With 9Mm Nitrile Rubber Tube Liquid Line.Incl Charges For Rapping The Whole Pipe. 7 Supply & Fixing Pipe Insulation In Suction Line 5 / 8 With 9Mm Nitrile Rubber Tube Suction Line Incl. Charges For Rapping The Whole Pipe. 8 Control Copper Cabling From Condensing To Unit And Control Panela ) 4 Core 2.5 Sq.Mm Communication Cable ( Havells / Fonolex / Mescab / Kei ) 9 Charges For Drain Pipe Work Incl Charges 32Mm Dia Pvc / Hdpe Harded Pipes With Insulation, Fitting, Accessories, Bends, Elbows, Tees, Flanges, Tappings, Wall Sleeves, Hangers, Supports, Anchors. And After The Work Cementing The Same. ( Supreme ) 10 Supplying, Fabrication & Fixing 4 Nos. M.S U-Channel Of 6 Mm Thick Of Size ( 75 Mm X 40 Mm X 40 Mm ) Of 1.2Mtr+ 200 Mm In Grounting Length For Making Platform For Installation Of Outdoor Unit Of 5 Tr Ton Concealed Type Split Ac Incl. Drillingnos Holesin Each Channel Including Cutting Holes Into The Wall & Grouting The Same With Cement Concrete ( 1:1 ½ :3 ) Etc. Fabricated With Horizontal Angle Of 25 Mm X 25 Mm X 3 Mm Including Supporting Angle 50 Mm X50mm X 6 Mminplatform In Outer Edge . Area Of The Platform Is2mtr. X 1.2Mtr. The Rectangular Stucture Will Provide Protective Guard For Outdoor Unit By 12 Sqmm Square Bar.Minimum The Protective Guard Size : Wxdxh =1600X1200x 750 Mm. For Maintenance Purpose .The Gap Between Each 12 Sq Bar Should Be Not More Than 3 Inch In Pretective Guard . 11 Supply And Fixing Of Horizonal Support For Indoor Unit By Ms Angle Of Size Of 50X50x6 Mm And Length Of 4 Ft ( 2 Nos For Each Idu ) , Total 4 Nos .8 Inch Of One Side Of Each Angle Grouted In Inner Wall Of The Room . 2 Nos 10 / 12 Mm Hole Should Be Done In Every Angle.Angle Should Be Painted By Red Oxide And Enamel Paint. ( Note As The Indoor Unit Are Ceiling Suspended And Condition Of The Ceiling Are Not Good , This Arrangement For Extra Protection. ) 12 Supply And Fixing Of Al. Powder Coated Continuous Grill 13 Part -Ii, E.I 14 Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire ( Havelles / Finnolex ) In 20Mm Size Pvc Rigid Conduit Fr ( Precision Make ) Incl. Necy. Fittings As Required 15 A ) 4 X 84 / 0.3 ( 6 Sqmm ) + 2 X 56 / 0.3 ( 4 Sqmm ) Ecc Tpndb To Ac 16 B ) 2 X 36 / 0.3 ( 2.5 Sqmm ) + 1 X 22 / 0.3 ( 1.5 Sqmm ) Ecc For Computer Board & Power Board 17 Supplyof 415V Timer Db ( Equivalent Of 2+12 Way Spn Double Door Db In Size ) With Steel Sheet Enclosure Double Door, Phosphitised Powder Coated, Neutral Bar, Din Rail With Ip- 43 Protection Comprises With 1 No.40A Fp Mcb ( C Curve, 10Ka ) , 1 No.24 Hours Programming Time Switch ( L&T / Aproved Make ) With 15 Min Minimum Switching Time Of Any Time And Any Day And 1No 32A 3Pole Contractor ( Make- L&T / Approved ) Complete Withinternal Wiring By Suitable Sizze Of Copper Wire And Provision For Earthing Attachment Including Led Indication Light For Running Condition With Locking Arrangement & Including On / Off Push Button ( Make- L&T / Approved ) . 18 Supply & Fixing 240 V, 2 Nos. 6A, & 2 Nos. 20A Plug Socket With Separate 2 Nos. 6 A & 2 Nos. 20A Piano Key Type Switch, Indicator & 16A Kit-Kat Flush Type Fuse ( Brand Approved By Eic ) On Sheet Metal Switch Board Embedded In Wall Incl. S & F 240X200x65mm Ms ( 16Swg ) Switch Board And Bakelite / Perspex Top Cover Of 3Mm Thick By Brass Screws After Making Housing For Switch By Cutting Bakelite / Perspex Cover And Making Necessary Connections As Required 19 Supply & Fixing 4 Pole Mcb Enclosure With 1No. 415V 40 Amp 4-Pole Mcb ( Legrand / Siemens / Abb ) To Be Fixed Concealed In Wall & Mending Good The Damages To Original Finish Incl. Painting, Connection & Provision For Earthing Attachment As Per Direction Of E.I.C 20 Supply & Fixing 4 Pole Outdoor Typeenclosure ( Sintex - 3020 ) With 1No. 415V 40 Amp 4-Pole Isolator ( Legrand / Siemens / Abb ) To Be Fixed Concealed In Wall & Mending Good The Damages To Original Finish Incl. Painting, Connection & Provision For Earthing Attachment As Per Direction Of E.I.C 21 Finishing Of The Pvc Insulated Wire Ends By Socketting With Pin / Ring Type Copper Sockets And Insulated Tapes Etc., Including Supplying Sockets, Tapes. 22 A ) 6 Sqmm 23 B ) 4 Sqmm

Key Value

Document Fees
Refer document
EMD
INR 5819.0 /-
Tender Value
INR 2.90 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail