Durgapur Projects Limited has published Tender For Procurement Of Clamps And Connectors For Different 132Kv And 220Kv Switchyard Inside Dpps. Submission Date for this Tender is 09-03-2024. Electrical Insulators Tenders in Paschim Bardhaman West Bengal. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 22-Feb-2024 | Extension of Technical Bid Opening Date | Date | 09-03-2024 |
Sl. No. | Item Description |
1 | PROCUREMENT OF CLAMPS AND CONNECTORS FOR DIFFERENT 132KV AND 220KV SWITCHYARD INSIDE DPPS |
2 | TERMINAL CONNECTOR FOR S&S MAKE ISOLATOR’S PAD TO SINGLE ACSR MOOSE CONDUCTOR, 132KV RATED WITH MIN. 10 NOS. M12 BOLTS, NUTS, WASHERS.( HORIZONTAL TAKE OFF) |
3 | CLAMP TYPE CONNECTOR FOR CT AL STUD (DIA.-45MM) TO TWIN ACSR MOOSE CONDUCTOR(HORIZONTAL TAKE-OFF) WITH MIN. 12 NOS. M12 BOLTS, NUTS, WASHERS. |
4 | TERMINAL CONNECTOR FOR ABB MAKE ISOLATOR’S PAD TO SINGLE ACSR MOOSE CONDUCTOR, 132KV RATED WITH MIN. 10 NOS. M12 BOLTS, NUTS, WASHERS.( HORIZONTAL TAKE OFF) |
5 | TERMINAL CONNECTOR FORISOLATOR’SCU STUD( DIA-50MM) TO SINGLE ACSR MOOSE CONDUCTOR, 132KV RATED WITH MIN. 12 NOS. M12 BOLTS, NUTS, WASHERS.( UNIVERSAL TAKE OFF) |
6 | RIGID TYPE BUS SUPPORT CLAMP TO HOLD SINGLE ACSR MOOSE CONDUCTOR ON BPI (96MM PCD) |
7 | RIGID TYPE BUS SUPPORT CLAMP TO HOLD TWIN ACSR MOOSE CONDUCTOR ON BPI (127 MM PCD) |
8 | 132 KV BUNDLE SPACER FOR TWIN ACSR MOOSE CONDUCTOR. |
9 | 220 KV BUNDLE SPACER TWIN ACSR MOOSE CONDUCTOR. |
10 | L-SHAPED TERMINAL CONNECTOR FOR 220 KV CT CU STUD( DIA-30MM) TO SINGLE ACSR MOOSE CONDUCTOR(UNIVERSAL TAKE-OFF) WITH BIMETALLIC SIM AND MIN. 12 NOS. M12 BOLTS,NUTS,WASHERS. |
11 | TERMINAL CONNECTOR FOR 220KV CT STUD(DIA-30MM) TO TWIN ACSR MOOSE CONDUCTOR .( HORIZONTAL TAKE OFF) WITH BIMETALLIC SIM AND MIN. 12 NOS. M12 BOLTS, NUTS, WASHERS. |
12 | TERMINAL CONNECTOR FOR 132 KV CT STUD(DIA-30MM) TO SINGLE ACSR MOOSE CONDUCTOR .( HORIZONTAL TAKE OFF) WITH BIMETALLIC SIM AND MIN. 12 NOS. M12 BOLTS, NUTS, WASHERS. |
13 | RIGID TYPECONNECTOR FOR 220 KV PG ISOLATOR PAD TO 4’’ IPS AL TUBE. |
14 | TEE CONNECTOR( BOLTED TYPE) SUITABLE FOR SINGLE ACSR MOOSE TO SINGLE ACSR MOOSE CONDUCTOR,132 KV RATED WITH MIN. 12 NOS. M12 BOLTS, NUTS, WASHERS. |
15 | TEE CONNECTOR( BOLTED TYPE) SUITABLE FOR TWIN ACSR MOOSE TO SINGLE ACSR MOOSE CONDUCTOR,132 KV RATED WITH MIN. 18 NOS. M12 BOLTS, NUTS, WASHERS. |
16 | PARALLEL GROOVE CLAMP(BOLTED TYPE) FOR ACSR MOOSE TO ACSR MOOSE CONDUCTOR,132 KV RATED WITH MIN. 4 NOS. M12 BOLTS, NUTS, WASHERS. |
17 | TERMINAL CONNECTOR( BOLTED TYPE) SUITABLE FOR 220 KV BHEL MAKE MOCB PAD TO ACSR MOOSE CONDUCTOR .( HORIZONTAL TAKE OFF) WITHMIN. 15 NOS. M12 BOLTS, NUTS, WASHERS. |
18 | 132 KV SF 6 BREAKER TERMINAL PAD CONNECTOR FOR ACSR MOOSE CONDUCTOR (WITH MIN.14 NOS. M12 BOLTS,NUTS, WASHERS.) |
19 | EXPANSION TYPE CONNECTOR FOR 220 KV CB PAD TO 4’’ IPS AI TUBE ( HORIZONTAL TAKE-OFF) |