| 1 | Dismantling flat wooden or asbestos cement sheet ceiling with frame work including stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 6 / 296Specification No : Bd.W.8Spec. Page No : 587 |
| 2 | Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 9 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 3 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts excetra complete.Item / Page No : 13 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 4 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 15 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 5 | Removing ventilators and small windows with frame and stacking the materials with all leads lifts excetra complete.Item / Page No : 16 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 6 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 19 / 297Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 7 | Dismantling the reinforced cement concrete work 1:2:4 and sorting out the materials such as steel excetra as directed and stacking them within the specified lead as directed excetra complete.Item / Page No : 29 / 297Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 8 | Removing battens from roof and stacking them as directed with all leads and lifts excetra complete.Item / Page No : 33 / 297Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 9 | Removing purlins from roof including stacking as directed with all leads, lifts, excetra complete.Item / Page No : 35 / 298Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 10 | Providing and fixing 6 milimetre thick commercial plywood with jungle wood frame work of 50 milimetre X 35 milimetre size at 60 centimetre on both ways for closing the window portion/ openings for protection from falling debris, dust, excetra including cutting, fixing with nails and removing after the same after completion of the work. (To be used after approval of Superintending Engineer) (For Ground Floor)Item / Page No : 57 / 300Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 11 | Providing and applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scrapping, applying french polishing, scaffolding, if required, excetra complete. (For Ground Floor)Item / Page No : 9 / 222Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 12 | Providing and fixing Indian teak wood plank ceilling 20 milimetre thick plain underside tounged and groved including iron screws, scaffolding, if necessary, including one primer coat on under side and one coat of coal tar on upper side, excetra complete. (For Ground Floor)Item / Page No : 5 / 230Specification No : Bd.Q.3Spec. Page No : 421 |
| 13 | Providing and fixing Indian teak wood framed collar beam / king post / queen post truss, with all iron work including scaffolding, if necessary, and one coat of primer, excetra complete. (For Ground Floor)Item / Page No : 6 / 230Specification No : Bd.Q.4Spec. Page No : 422 |
| 14 | Providing and fixing in teak wood frame collar beam / king post / queen post truss, with all iron work including scaffolding, if necessary and primer coat, excetra complete. (For Ground Floor)Item / Page No : 7 / 230Specification No : Bd.Q.4Spec. Page No : 422 |
| 15 | Providing and fixing country teak wood common rafters, purlins and purlin cleats, hip rafters, jack rafters, ridges, wall plates, post plates and posts for roofing excetra including scaffolding, if necessary, all iron work and one coat of primer, excetra complete. (For Ground Floor)Item / Page No : 8 / 230Specification No : Bd.Q.5Spec. Page No : 423 |
| 16 | Providing and fixing teak wood common rafters, purlins and purlin cleats, hip rafters, jack rafters, ridges, wall plates, post plates and posts for roofing, excetra including scaffolding, if necessary, all iron work and one coat of primer, excetra complete. (For Ground Floor)Item / Page No : 9 / 230Specification No : Bd.Q.5Spec. Page No : 423 |
| 17 | Providing and fixing teak wood hand rail of 60 milimetre X 75 milimetre as per detailed drawings or as directed by the Engineer, including french polishing, excetra complete. (For Ground Floor)Item / Page No : 10 / 230Specification No : Bd.Q.8Spec. Page No : 425 |
| 18 | Providing and fixing country teak wood two way trellis work with battens or laths 2.5 centimetre X 1.2 centimetre and 5 centimetre X 5 centimetre openings including frame of 8 centimetre X 5 centimetre vertical and horizontal scantlings and coat of primer, excetra complete. (For Ground Floor)Item / Page No : 11 / 230Specification No : Bd.Q.6Spec. Page No : 424 |
| 19 | Providing and fixing decorative teak plywood veneer linning 4 milimetre thick with backing of teak wood frame work of battens 12 milimetre X 25 milimetre at 30 centimetre center to center fixed to walls and pillars with 12 Milimeter thick plywood building without skirting and cornice as per drawings including necessary iron work and finishing the exposed wood work with french polish, excetra complete. (For Ground Floor)Item / Page No : 13 / 231Specification No : Bd.Q.18Spec. Page No : 431 |
| 20 | Providing and fixing Indian teak wood eaves boards 15 centimetre wide and 25 milimetre thick plain decorative type including scaffolding and painting with two coats, excetra complete. (For Ground Floor)Item / Page No : 16 / 231Specification No : Bd.Q.19Spec. Page No : 432 |
| 21 | Providing and fixing country teak wood barge boards 22 centimetre wide and 20 milimetre thick plain type including scaffolding and painting in two coats, excetra complete. (For Ground Floor)Item / Page No : 19 / 231Specification No : Bd.Q.21Spec. Page No : 433 |
| 22 | Providing and fixing shutters to wall cupboard consisting of teak wood styles and rails 25 milimetre thick and 75 milimetre wide with panel insert of 12 milimetre thick particle board with one approved coloured laminated face on one side, 1.5 milimetre thick bonded with phenol Formaldehyde synthetic resin including lipping, beading,iron oxidised fixtures and fastening and oil primer coat, excetra complete. (Excluding cupboard frame) (For Ground Floor)Item / Page No : 22 / 232Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 23 | Providing and fixing 3.5 milimetre to 4 milimetre thick Veneer finish wall panaling made out of 50 milimetre X 25 milimetre (finished size) country cut teak wood frame work or size of 600 milimetre X 600 milimetre center or as per site condition covered by 6 milimetre thick marine plywood generally confiriming to Indian Standard : 710-1980 finished with 3.5 to 4 milimetre thick matching Veneer of approved color and in satin wallnut groov matched veneer pattern and design including melamine polishing and design with antitermite treatment, excetra to plywood and woodwork with ten years guarantee bond, excetra including all lead and lifts complete as per Architects Drawing and instructions of Engineer Incharge. (For Ground Floor)Item / Page No : 26 / 232Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 24 | Providing and fixing country teak wood runner size 150 milimetre X 75 milimetre over partition, including rounding, fixing in the masonry where necessary, beading on sides, excetra complete. (For Ground Floor)Item / Page No : 92 / 263Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 25 | Providing and fixing teak wood cover moulding 45 milimetre X 20 milimetre over doors and windows in the required shape and size as per drawing, including all mouldings and finishing with french polishing, excetra complete. (For Ground Floor)Item / Page No : 93 / 263Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 26 | Providing and fixing in position, stage flooring made from 18 milimetre plywood 1200 milimetre X 2400 milimetre and 18 milimetre teak wood planks 100 milimetre X 800 milimetre having tounge and groove on sal-wood frame of 50 milimetre X 100 milimetre at 600 milimetre center to center on stage surface, including cost of required cut-outs, decorative mouldings / finishing items / polish, excetra as per architectural and acoustical design and instructions and complete in all aspects including all materials, labour, finishing, excetra complete.Item / Page No : 6 / 353Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 27 | Providing and fixing Manalore tiled roofing with class \"AA\" tiles including securing the last course of tiles near the eaves with steel flat 40 milimetre X 3 milimetre and 1.22 milimetre wire, fixing country teak wood sloping battens of 25 milimetre X 12 milimetre teak wood horizontal battens of 50 milimetre X 25 milimetre over the slopping battens, all iron work and coal tarring the battens, excetra complete. (excluding ridge and hip tiles) (For Ground Floor)Item / Page No : 2 / 233Specification No : Bd.R.2Spec. Page No : 450 |
| 28 | Providing and fixing Mangalore tile roofing with class \"AA\" tiles in cement mortar 1:4 on sloping slab including necessary scaffolding, curing, finishing, excetra complete. (For Ground Floor)Item / Page No : 33 / 236Specification No : Bd.R.3ASpec. Page No : 449 |
| 29 | Providing and fixing country teak wood battens 50 milimetre X 25 milimetre for Mangalore tile roof work with all iron work, scaffolding and oiling the battens, excetra complete. (For Ground Floor)Item / Page No : 29 / 236Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 30 | Providing and fixing plain zinc sheeting of 0.80 milimetre thick (22 B.W.G) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt, galvanised iron screw and bolts and lead and bitumen washers, excetra complete. (Weight 6.8 killogram per square metre) (For Ground Floor)Item / Page No : 5 / 233Specification No : Bd.R.5Spec. Page No : 452-453 |
| 31 | Providing and laying rubble stone flooring laid in cement mortar 1:3 as per drawing and technical specifications, excetra complete. (using ARTIFICIAL SAND).Item / Page No : 76 / 100Specification No : MORTH-2500Spec. Page No : ---Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 32 | Supply and Fixing of Rock / Stone Finished Full Body Vitrified Steptiles with thick Bullnose for Ready to install Treads and Risers, 16 milimetre thick and of required width in plain pattern including Cement float, filling joints, with neat cement slurry, Natural sand, curing and cleaning complete. with prior approval of concerned Superitending Engineer.Item / Page No : 18 / 333Specification No : BD-MSpec. Page No : ---Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge. |
| 33 | Providing antitermite treatment to wooden frames of doors / windows of existing building as per Indian Standard 6313 (Part-III) by drilling 6 milimetre diameter hole at four corners on one side and four corners on other side at a downward angle of about 45 degree at the junction of wood work and masonry and injecting 150 millilitres of Chlorodane 5 percent water closet and sealing by filling putty, excetra complete covering two years guarantee on bond paper. (For Ground Floor)Item / Page No : 26 / 156Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge.2. The amount of 10 percent of the total cost of the completed item sahll be retained as retention money for the full guarantee period of ten years.3. If the use of any chemical is found banned by the Government, proper substitute chemical will be allowed to be used as per manufactures code of practice. The chemical shall be got approved from Engineer in-charge.4. The recoupment of the damages if any found and communicated to the contractor in writing is not made good within two weeks from the date of receipt of such communication by him, the same shall be carried out departmentally on his behalf and cost thereof shall be met with from sum withheld as aforesaid. In case the sum recoverable from the contractor is more than that of the sum of withheld amount, thedifference shall stand recoverable as arrears of land revenue from the contractor under clause 20 of original contract.5. The mode of measurement shall be on square metre basis. |
| 34 | Providing antitermite treatment to joints of wooden beams / joints used for roof work of the existing building as per Indian Standard 6313 (Part-III) by drilling 6 milimetre diameter holes at a downward angle of about 45 degree at the junction of wood work and masonry and injecting 80 millilitres of Chlorodane 5 percent water closet and sealing by filling putty, excetra complete covering two years guarantee on bond paper. (For Ground Floor)Item / Page No : 27 / 156Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge.2. The amount of 10 percent of the total cost of the completed item sahll be retained as retention money for the full guarantee period of ten years.3. If the use of any chemical is found banned by the Government, proper substitute chemical will be allowed to be used as per manufactures code of practice. The chemical shall be got approved from Engineer in-charge.4. The recoupment of the damages if any found and communicated to the contractor in writing is not made good within two weeks from the date of receipt of such communication by him, the same shall be carried out departmentally on his behalf and cost thereof shall be met with from sum withheld as aforesaid. In case the sum recoverable from the contractor is more than that of the sum of withheld amount, thedifference shall stand recoverable as arrears of land revenue from the contractor under clause 20 of original contract.5. The mode of measurement shall be on square metre basis. |
| 35 | Providing antitermite treatment around the periphery of the existing building as per Indian Standard 6313 (Part-III) by excavating trenches of 20 centimetre width and exposing the sides of columns and plinth beams upto a depth of 300 milimetre and injecting one percent of Chlorodane emulsion concentrate at the rate of 2.25 litres per running metre and refilling the trenches, excetra complete covering 2 years guarantee on bond paper.Item / Page No : 29 / 156Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge.2. The amount of 10 percent of the total cost of the completed item sahll be retained as retention money for the full guarantee period of ten years.3. If the use of any chemical is found banned by the Government, proper substitute chemical will be allowed to be used as per manufactures code of practice. The chemical shall be got approved from Engineer in-charge.4. The recoupment of the damages if any found and communicated to the contractor in writing is not made good within two weeks from the date of receipt of such communication by him, the same shall be carried out departmentally on his behalf and cost thereof shall be met with from sum withheld as aforesaid. In case the sum recoverable from the contractor is more than that of the sum of withheld amount, thedifference shall stand recoverable as arrears of land revenue from the contractor under clause 20 of original contract.5. The mode of measurement shall be on square metre basis. |
| 36 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 4 / 209Specification No : Bd.L.2Spec. Page No : 368Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work.2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge.3. Finishing shall be plain and in line, level and plumb.4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days.5. Application of sand faced treatment shall be commenced only afterpassing the base coat Engineer in-charge.6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 37 | Providing and applying gypsum plaster (with gypsum material of approved make) with finishing with gypsum material in 10 milimetre to 13 milimetre thickness to previously plastered surface / or on new brick surface (excluding rough cast plaster) in all positions including preparing and finishing the surface, scaffolding, excetra complete. (For Ground Floor)Item / Page No : 31 / 211Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 38 | Providing and applying two coats of synthetic enamel paint of approved colour to new / old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat), excetra complete. (For Ground Floor)Item / Page No : 7 / 223Specification No : Bd.O.5Spec. Page No : 405Additional Specifications : 1. The shade of paints shall be got approved by the Engineer in-charge before use.2. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use. |
| 39 | Removing old paint from steel and other metal surfaces and making the surface even with hand scrapping, scaffolding, excetra complete. (For Ground Floor)Item / Page No : 18 / 224Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 40 | Providing and applying priming coat over new wood and wood based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matters, sand papering and knotting, scaffolding, excetra complete. (For Ground Floor)Item / Page No : 19 / 224Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 41 | Providing and applying priming coat over new / old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matters and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding, excetra complete. (For Ground Floor)Item / Page No : 20 / 224Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 42 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old surface in three coats including scaffolding, preparing the surface (excluding primer coat), excetra complete. (For Ground Floor)Item / Page No : 13 / 228Specification No : Bd.P.6Spec. Page No : 414Additional Specifications : 1. The priming coat should be applied and got approved from Engineer in-charge.2. The shade of paints shall be got approved by the Engineer in-charge before use.3. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use. |
| 43 | Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding ,etc. complete as directed. (For Ground Floor)Item / Page No : 19 / 228Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 44 | Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10 percent and oil 15 to 20 percent with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours.Scrapping withemery paper 180 and wipe clean. Applying wall primer with brush with mineral turpentine 8 to 10 percent and oil 15 to 20 percent with roller. Scrapping emery paper 320 and wipe clean,interior wall finish luster first coat with brush/ rubber/ spray with mineral turpentine 7 to 9 percent and Oil with roller 19 to 21 percent. After 8 hours of activity, applying second coat or wall finish Lustre with mineral turpentine 7 to 9 percent with brush and Oil with roller 19 to 21 percent after allowing dry for the period of 6 to 8 hours activity.(With prior approval of S.E.) (For Ground Floor)Item / Page No : 20 / 228Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 45 | Providing and applying a silicon base water repellent stone sealers, on brick / stone masonry / concrete surfaces in two coats by spraying. Including cleaning / sand blasting for removing dirt / cement mortar patches, excetra by force water jet, wire brushing, excetra complete. (For Ground Floor)Item / Page No : 116 / 383Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 46 | Providing tuck pointing with cement mortar 1:3 for stone / brick masonry including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 18 / 210Specification No : Bd.L.16Spec. Page No : 373Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 47 | Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For Ground Floor)Item / Page No : 34 / 212Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 48 | Providing groove to required size at specified location as directed by Engineer, at junction of brick masonary wall and reinforced cement concrete beams or column, at junction of composite masonary, including scaffolding, finishing curing, excetra complete.Item / Page No : 37 / 212Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 49 | Providing and applying french polishing for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding, excetra complete as directed. (For Ground Floor)Item / Page No : 5 / 222Specification No : Bd.N.1.3Spec. Page No : 399 |
| 50 | Providing and applying french polishing to new wood work for required finish including kontting, preparing the surface, scaffolding, excetra complete as directed. (For Ground Floor)Item / Page No : 6 / 222Specification No : Bd.N.1.3Spec. Page No : 399 |
| 51 | Providing and fixing country cut teak wood double or single leaf panelled shutters, 35 milimetre thick styles and freze rail 95 milimetre X 35 milimetre thick with lock and bottam rail 195 milimetre X 25 milimetre thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting three coats, excetra complete. (For Ground Floor)Item / Page No : 8 / 246Specification No : Bd.T.11,Bd.T.12Spec. Page No : 482,483Additional Specifications : Door shutter shall be got approved by Engineer in-charge. |
| 52 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For Ground Floor)Item / Page No : 1 / 245Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 53 | Providing and fixing fully glazed double leaf window shutter with openable fanlight including country cut teak wood 25 milimetre thick style and rails with plain / obscured glass panels 5 milimetre thick as per drawings or as directed by the engineer in charge, with stainless steel fixtures and fastening and finishing the wood work three coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 15 / 247Specification No : Bd.T.42Spec. Page No : 503Additional Specifications : Window shutter shall be got approved by Engineer in-charge. |
| 54 | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0Additional Specifications : 1. The amount of the laboratory testing charges will be paid to the contractor after submission of the original receipt from the Office of the Vigilance and Quality Control withname of work mensioned on the original receipt within the stipulated period of work.2. The frequency of tests will be as per the instructions of Vigilance and Quality Control, Pune; vide their letter No. Prasha/2647/ 2010 dated 30/10/2010.3. No extra claim shall be entertained on account of additional tests required and material transportation charges for tests.4. In addition to above, the conditions under clause 25 - Samples and Testing of Material, under \"Additional General Conditions and Specifications\" of this tender document shall be applicable.5. Above / below percentage quoted by the contractor will not be applicable for this item.Crushing Value / Compressive Strength, Water Absorption, Specific Gravity Test for Stone / Rubble1 Test per Source |
| 55 | Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Artificial Sand1 Test per Source |
| 56 | Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.)Item / Page No : 3 / 0Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5.2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work.3. Above / below percentage quoted by the contractor will not be applicable for this item. |