Tender For Co 2 Store Rooms For Mountaineering Expedition Equipment Parkour Equipment And Div-Ing Equipment For Sws At Manesar, manesar-Haryana

National Security Guard-NSG has published Tender For Co 2 Store Rooms For Mountaineering Expedition Equipment Parkour Equipment And Div-Ing Equipment For Sws At Manesar. Submission Date for this Tender is 08-02-2024. Building Work Tenders in manesar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

41913565
Tender For Co 2 Store Rooms For Mountaineering Expedition Equipment Parkour Equipment And Div-Ing Equipment For Sws At Manesar
Open Tender
Indian
Haryana
manesar
08-02-2024

Tender Details

Co 2 Store Rooms For Mountaineering Expedition Equipment Parkour Equipment And Div-Ing Equipment For Sws At Manesar

Key Value

Document Fees
Refer document
EMD
INR 112094.0 /-
Tender Value
INR 56.04 Lakhs /-

BOQ Items

Name of Work: C/O 2 store rooms for mountaineering expedition equipment/Parkour equipment and diving equipment for SWS at Manesar.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
2All kinds of soil
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif.
4Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
5Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth
61:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from naturalsources :10gradedstoneaggregate40mm nominal size derived from natural sources)
7Makingplinthprotection 50mmthickofcementconcrete 1:3:6 (1cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
8Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level :
91:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
10Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement:
111:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
12Centering and shuttering including strutting, propping etc. and removal of form for
13Foundations,footings,basesof columns,etc.formass concrete
14Shelves (Cast in situ)
15Lintels,beams,plinthbeams,girders,bressumersand cantilevers
16Columns, Pillars, Piers, Abutments, Posts and Struts
17Edges of slabs and breaks in floors and walls
18Under 20 cm wide
19Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level.
20Thermo-Mechanically Treatedbars of gradeFe-500D or more.
21Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level.
22Thermo-Mechanically Treatedbars of gradeFe-500D or more.
23Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
24Cement mortar 1:6(1 cement :6 coarse sand)
25Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
26Cement mortar 1:6(1 cement : 6 coarse sand)
27Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
28Cement mortar 1:4(1 cement :4 coarse sand)
29Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
30Providingandfixing 18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters,window sills,facias andsimilar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
31Granite stone slab of colour black, Cherry/Ruby red
32Area of slab over 0.50 sqm
33Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, allnecessary fittingscomplete,includingapplyingaprimingcoat of approved steel primer.
34Using M.S. angels 40x40x6 mm for diagonal braces
35Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S.Sheet, jointsmitred, weldedand grinded finish, withprofiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
36Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
37Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
3825 mm thick
39Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
40Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
41110 mm diameter
42Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion.
43Bend 87.5°
44110 mm bend
4512 mm cement plaster of mix:
461:6 (1 cement: 6 coarse sand)
4715 mm cement plaster on rough side of single or half brick wall of mix:
481:6(1 cement: 6 coarse sand)
496 mm cement plaster of mix:
501:3(1 cement :3 fine sand)
51Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:
52New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre
53Finishing walls with Acrylic Smooth exterior paint of required shade:
54New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
55Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
56Two or more coats on new work
57Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
58Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :
59For fixed portion
60Powder coated aluminium (minimum thickness of powder coating 50 micron)
61Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
62Powder coated aluminium (minimum thickness of powder coating 50 micron)
63Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
64With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
65Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
66With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
67Electrical
68Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
69Group C
70Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
71Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
72Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
732 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
742 X 6 sq. mm + 1 X 6 sq. mm earth wire
75Supplying and drawing following size of FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required
761 x 1.5 sq. mm
772 x 1.5 sq. mm
783 x 4 sq. mm
79Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
8020 mm
8125 mm
8250 mm
83Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
845/6 A switch
8515/16 A switch
863 pin 5/6 A socket outlet
876 pin 15/16 A socket outlet
88Telephone socket outlet
89Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
91Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
921 or 2 Module (75mmX75mm)
933 Module (100mmX75mm)
94Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
95Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
96Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
97Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
98Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required.
99Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1006 way (8 + 18), Double door
101Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.(L&T /Legrand /ABB /Schneider/Siemens.)
102For 6 way, Double door TPN MCBDB
103Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
104Single pole
105Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
106Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
10763 A
108Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
10963 ATriple pole and neutral
110Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
111Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.
112Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
113Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclo sure with cover plate having locking arrangement and wa tering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
114Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
115Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
116Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 8, Air delivery minimum 215 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%,without remote and compatible with existing step electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty)
117Supplying, installation testing, and commissioning100 W highbay LED luminaire, complete with driver, LEDs with optical lenses, toughened glass cover, mounting bracket, and pressure-die-cast aluminium alloy housing, including installation of luminaire on the ceiling, including connections, earthing, providing fixing fasteners, etc., as required. The fixture should have a minimum system efficacy of 140 lumens per watt, ingress protection of IP66, and a mechanical impact resistance rating of IK >= 7. The fixture driver should have an operating voltage range of 140–270 V, surge protection of = 10 KV, and a PF of > 0.9. The fixture shall be designed for a system life of 50,000 hours at 70% lumen maintenance. LM 79 and LM 80 reports need to be submitted from a NABL or UL-accredited lab to verify the above parameters. The contractor shall provide a warranty for the above-LED light fixtures for five years. (Approved Manufacturers: Phillips, Havells, Wipro, and Bajaj, TRILUX)
118Supplying, installation, testing and commissioning of 70 Watt LED street light luminaire made up of die-cast aluminium housing, with IP66 degree of protection, complete with the driver, LEDs with optical lens, toughened glass cover, etc. The luminaire should have suitable for operation on voltage range 140-270V, 1F, 50Hz AC supply system, and a mechanical impact resistance rating of lk>=07. surge protection of = 10KV, PF= 0.90 and minimum system luminous efficacy of 120 lm/W. The luminaire shall be designed for an average system life L70B50: 50000 hours and suitable for mounting on the pole bracket up to outer dia 50 mm, including installation on existing street light pole bracket connections and earthing etc., as required. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify the above parameters.
119Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole/ wall including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
120Supplying and installation of 450 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(HavellsTurbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard)
121Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required.
122450 mm
123Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1200 mm (nominal size) with a minimum system lumen output of 4800 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature5500K - 6500 K, Average life L70B50: 50000 hours, THD = 10%, suitable for operation on 140-270V, 1F, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required.
124Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1F, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required
125Supply, Installation, Testing and commissioning of outdoor type totally enclosed, dust and vermin proof, pedestal mounted INSPECTION BOX / JUNCTION BOX of a suitable size but not less than 600 mm wide X 450 mm height X 450 mm (deep) fabricated from 2 mm thick CRCA sheet steel having front and back openable doors with locking arrangement on both sides, tapered top (roof), including detachable cable gland plates made of 3 mm thick CRCA sheet, including pre-paint treatment, phosphating and powder coating by approved Siemens grey paint, consisting of 300 Amps 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals, etc. as required, suitable for operation on 433 volts, 50 Hz, 3-phase, 4-wire A.C. supply system, the entire panel shall have one common G.I. bar of size 25 mm x 5 mm at the rear with 2 earth studs or terminals, a danger notice plate fixed, etc., complete as required. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground and 300mm above ground).
126Providing and fixing 3 mm thick PVC/phenolic laminatedround sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required.
127Supplying and laying of G.I. pipe of 50 mm dia.(nominal),medium class, ISI markedinwall / floorincluding cuttingchase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable)
128Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [Make-Comet/Hex/Dowells/Jainson]
1293½ X 35 sq. mm (32mm)
130Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
131Add 1.0633 multiplying factor for GST on DSR
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail