Assam Rifles-AR has published Tender For Special Repairs To 04 Nos Or Married Accommodation (G+1) Building No. T-I-51 To 54, Special Repairs To 04 Nos Other Ranks Married Accommodation (G+I) Building No. T-I-55 To 58” And Special Repairs To 01 No Single Men Barrack Building No Ar-1. Submission Date for this Tender is 08-02-2024. Building Work Tenders in East Khasi Hills Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

41911735
Tender For Special Repairs To 04 Nos Or Married Accommodation (G+1) Building No. T-I-51 To 54, Special Repairs To 04 Nos Other Ranks Married Accommodation (G+I) Building No. T-I-55 To 58” And Special Repairs To 01 No Single Men Barrack Building No Ar-1
Open Tender
Indian
Meghalaya
East Khasi Hills
08-02-2024

Tender Details

Special Repairs To 04 Nos Or Married Accommodation ( G+1 ) Building No. T-I-51 To 54, Special Repairs To 04 Nos Other Ranks Married Accommodation ( G+I ) Building No. T-I-55 To 58” And Special Repairs To 01 No Single Men Barrack Building No Ar-14 ( G+I ) Of Arasu Happy Valley, Shillong

Key Value

Document Fees
INR 1500 /-
EMD
INR 138700.0 /-
Tender Value
Refer document

BOQ Items

Name of Work :“SPECIAL REPAIRS TO 04 NOS OR MARRIED ACCOMMODATION (G+1) BUILDING NO. T-I-51 TO 54", "SPECIAL REPAIRS TO 04 NOS OTHER RANKS MARRIED ACCOMMODATION (G+I) BUILDING NO. T-I-55 TO 58” AND "SPECIAL REPAIRS TO 01 NO SINGLE MEN BARRACK BUILDING NO AR-14 (G+I) OF ARASU HAPPY VALLEY, SHILLONG"
Sl. No. Item Description
1SCHEDULE ‘A’ PART-I (SCHEDULE OF ITEMS) SPECIAL REPAIRS TO 04 NOS OR MARRIED ACCOMMODATION (G+1) BUILDING NO. T-I-51 TO 54
2Dismantling doorswindows and ventilator (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below.
3Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
4Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
6Providing and fixing 35 mm thickwire gauge shutters using galvanized wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws with ISI marked M.S. pressed butt hinges bright finished of required size with hollock wood.
7Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
8Providing and fixing 30 mm thickwire gauge shutters using galvanized wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws with ISI marked M.S. pressed butt hinges bright finished of required size with hollock wood.
9Providing and fixing fly proof galvanized wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 2nd class teak wood beading.
10Renewing float glass panes of thickness 4 mm, with putty and nails wherever necessary including racking out the old putty.
11Providing and fixing stainless steel tower bolts 200x10 mm, ISI marked, anodised with necessary screws etc. complete.
12Providing and fixing stainless steel tower bolts 100x10 mm, ISI marked, anodised with necessary screws etc. complete.
13Providing and fixing stainless steel handles 125 mm, ISI marked, anodised with necessary screws etc. complete.
14Providing and fixing stainless steel sliding door bolts 300x16 mm, ISI marked with nuts and screws etc. complete.
15Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead with cement mortar 1:4 (1 cement : 4 fine sand).
16Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets.
17Providing and fixing 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door.
18Two coats distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification including preparing the surface smooth by scrapping, sand paperingincluding necessary repairs to scratches etc. complete.
19Painting with synthetic enamel paint of approved brand and manufacture to give an even shade with two or more coats on new work
20Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface including preparing the surface smooth by scrapping, sand paperingincluding necessary repairs to scratches etc. complete.
21Demolishing cement concrete 1:3:6 or richer mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
22Dismantling old plaster or skirting raking out joints as in roof surfaces and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
23Grading roof for water proofing treatment with Cement mortar 1:3 (1 cement : 3 coarse sand) cum
24Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
25Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
26Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-inCharge.
27Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440 mm (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.
28Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.1 Kitchen sink with drain board510x1040 mm bowl depth 250 mm
29Providing and fixing 100 mm sand cast Iron grating for gully trap.
30Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
31Providing and fixing M.S. stays and clamps for PVCpipes of diameter :100 mm
32Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
33Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.
34Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
35providing12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)
36Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing andeinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
37FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
38Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more.
39Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
40Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. sqm
41Providing and fixing on wall face unplasticised Rigid PVC water pipes 75 mm diameter, Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
42Providing and fixing on wall face unplasticised Rigid PVC water pipes 110 mm diameter, Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
43Providing and fixing on wall face unplasticised - PVC moulded Single tee with door 75x75x75 mm for unplasticised Rigid PVC water pipes Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
44Providing and fixing on wall face unplasticised - PVC moulded Single tee with door 110x110x110 mm for unplasticised Rigid PVC water pipes Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
45Providing and fixing on wall face unplasticised - PVC moulded 75 mm bend for unplasticised Rigid PVC water pipes Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
46Providing and fixing on wall face unplasticised - PVC moulded 110 mm bend for unplasticised Rigid PVC water pipes Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
47Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 20 mm nominal outer dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
48Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 25 mm nominal outer dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
49Providing and fixing uplasticised PVC connection pipe 15 mm nominal bore 45 cm length with brass unions.
50Providing and fixing C.P. brass bib cock 15 mm nominal bore of approved quality conforming to IS standards.
51Providing and fixing C.P. brass angle valve 15 mm nominal bore of approved quality conforming toIS standards.
52Half brick masonry with common burnt clay F.P.S. (non modular) bricks with cement mortar 1:4 (1 cement :4 coarse sand) of class designation 7.5.
53Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete25 mm diameter.
54Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
55Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
56Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etcKiln seasoned and chemically treated hollock wood
57Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 12.26.1 6 mm thick Cement fiber board as per IS: 14862
58Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.63 mm thick with zinc coating not less than 275 gm/m² metre
59M&L for wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit for caping -N - Casing with and including modular switch, suitable GI box and earthing the point with 1.5 sqm FR PVC insulated copper conductor single core cable etc as required all as specified and directed (Group A)
60M&L for wiring for twin control light point with 1.5 sqm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit or caping - N- casing including 2 way modular swithc, modular plate, suitable GI Box and earthing the point with 1.5 sqm.m FR PVC insulated copper conductor single core cable etc as required.
61Supplying and fixing following modules swithch/ socket on the existing modules plate & switch box including connections but excluding modules plate etc as required. (A) 15/16 amp switch
62(b) 5 pin 5/6 amp socket outlet
63(c) 5 pin 15/16 amp socket outlet
64(d) 2 way 5/6 amps switch
65(e)Bell push
66Supplying and fixing following size / modules GI box alongwith modules base & cover plat for modular swithes in recess etc as required. (a) 01 or 2 module (75mm x 75 mm)
67(b) 3 modules (100mmx75 mm)
68(c) 4 modules (125mmx75 mm)
69(d) 6 modules (200mmx75 mm)
70Supplying and fixing cal bell suitable for single phase 230 volts complete as required.
71Suplying and fixing 3 pin 5amp ceiling rose on the existing junction box/ etc as required.
72Earthing with GI earth plate 600mmx600mmx3mm thich including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc with charcal / coke and salt as required.
73Providing and fixing 25mm x 5mm GI strip on surface or in recess for connection etc as required.
74Supplying and fixing PVC batten / angle holder incl connection as reqd complete all as specified and directed.
75Supplying and fixing following way single pole and neutral, sheet steel MCB distribution board 240 valts on surface / recess complete, with finnel copper bus bar, neutral bus bar, earth bar, din bar, inter connection power ponted including earthing etc as rquired (But with out MCB/ RCCB/ ISOLATER) (a) 2+12 way double door
76supplying and fixing horizontal type three pole and nuteral, sheet steel MCCBditributio board, 415 V, on surface / recess, complete with 200 Amp tinned copper busbar, nutral busbar link, earthabar, dinbar, inter connection between incomer MCCB and busbar powder painter incl earthing etc. as required of size 8 way (4+24) double door
77S & F MCCB Triple pole, 160 A, 415 V, 50 HZ with rupturing capacity 16 KA.
78All as srl item No 27 here in before but 40 to 63 amps capacity and double pole type.
79S&F in replacement of MCB "C" Curve type, 10 Ka, 10 to 32 amp, single pole with lover load and short circuit protection complete all as directed.
80Wiring for circuit / submain wiring along earth wire with the 2x2.5 sqm+1x2.5 sqm earth wire of FRPVC insulated copper conductor, single core cable in casing caping as required.
81Wiring for circuit / submain wiring along earth wire with the 2x4 sqm+1x4 sqm earth wire of FRPVC insulated copper conductor, single core cable in casing caping as required.
82Fixing only pre-wired light fittings of LED/ flurecent / compact fluoverscent fittting with all accessories on ceiling / wall including connection with 1.5 sqm FR PVC insulated, coppr inductor, single core cable and earthing etc as required all as specified and directed. Note : Light fittings will be under Sch "B" Store.
83Fixing only exhaust fan of any sweep / type including making all electric connection complete all as specified and directed. Note : Exhaust fan will be issued under Sch "B" Store.
84SCHEDULE ‘A’ PART-II (SCHEDULE OF ITEMS) SPECIAL REPAIRS TO 04 NOS OTHER RANKS MARRIED ACCOMMODATION (G+I) BUILDING NO. T-I-55 TO 58
85Dismantling doorswindows and ventilator (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below.
86Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
87Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
88Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
89Providing and fixing 35 mm thickwire gauge shutters using galvanized wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws with ISI marked M.S. pressed butt hinges bright finished of required size with hollock wood.
90Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
91Providing and fixing 30 mm thickwire gauge shutters using galvanized wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws with ISI marked M.S. pressed butt hinges bright finished of required size with hollock wood.
92Providing and fixing fly proof galvanized wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 2nd class teak wood beading.
93Renewing float glass panes of thickness 4 mm, with putty and nails wherever necessary including racking out the old putty.
94Providing and fixing stainless steel tower bolts 200x10 mm, ISI marked, anodised with necessary screws etc. complete.
95Providing and fixing stainless steel tower bolts 100x10 mm, ISI marked, anodised with necessary screws etc. complete.
96Providing and fixing stainless steel handles 125 mm, ISI marked, anodised with necessary screws etc. complete.
97Providing and fixing stainless steel sliding door bolts 300x16 mm, ISI marked with nuts and screws etc. complete.
98Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead with cement mortar 1:4 (1 cement : 4 fine sand).
99Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets.
100Providing and fixing 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door.
101Two coats distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification including preparing the surface smooth by scrapping, sand paperingincluding necessary repairs to scratches etc. complete.
102Painting with synthetic enamel paint of approved brand and manufacture to give an even shade with two or more coats on new work
103Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface including preparing the surface smooth by scrapping, sand paperingincluding necessary repairs to scratches etc. complete.
104Demolishing cement concrete 1:3:6 or richer mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
105Dismantling old plaster or skirting raking out joints as in roof surfaces and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
106Grading roof for water proofing treatment with Cement mortar 1:3 (1 cement : 3 coarse sand) cum
107Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
108Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
109Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-inCharge.
110Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440 mm (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.
111Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.1 Kitchen sink with drain board510x1040 mm bowl depth 250 mm
112Providing and fixing 100 mm sand cast Iron grating for gully trap.
113Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
114Providing and fixing M.S. stays and clamps for PVCpipes of diameter :100 mm
115Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
116Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.
117Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
118providing12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)
119Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing andeinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
120FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
121Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more.
122Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
123Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. sqm
124Providing and fixing on wall face unplasticised Rigid PVC water pipes 75 mm diameter, Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
125Providing and fixing on wall face unplasticised Rigid PVC water pipes 110 mm diameter, Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
126Providing and fixing on wall face unplasticised - PVC moulded Single tee with door 75x75x75 mm for unplasticised Rigid PVC water pipes Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
127Providing and fixing on wall face unplasticised - PVC moulded Single tee with door 110x110x110 mm for unplasticised Rigid PVC water pipes Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
128Providing and fixing on wall face unplasticised - PVC moulded 75 mm bend for unplasticised Rigid PVC water pipes Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
129Providing and fixing on wall face unplasticised - PVC moulded 110 mm bend for unplasticised Rigid PVC water pipes Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
130Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 20 mm nominal outer dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
131Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 25 mm nominal outer dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
132Providing and fixing uplasticised PVC connection pipe 15 mm nominal bore 45 cm length with brass unions.
133Providing and fixing C.P. brass bib cock 15 mm nominal bore of approved quality conforming to IS standards.
134Providing and fixing C.P. brass angle valve 15 mm nominal bore of approved quality conforming toIS standards.
135Half brick masonry with common burnt clay F.P.S. (non modular) bricks with cement mortar 1:4 (1 cement :4 coarse sand) of class designation 7.5.
136Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete25 mm diameter.
137Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
138Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
139Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etcKiln seasoned and chemically treated hollock wood
140Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).1 2.26.1 6 mm thick Cement fiber board as per IS:14862
141Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.63 mm thick with zinc coating not less than 275 gm/m² metre
142E&M Portion M&L for wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit for caping -N - Casing with and including modular switch, suitable GI box and earthing the point with 1.5 sqm FR PVC insulated copper conductor single core cable etc as required all as specified and directed (Group A)
143M&L for wiring for twin control light point with 1.5 sqm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit or caping - N- casing including 2 way modular swithc, modular plate, suitable GI Box and earthing the point with 1.5 sqm.m FR PVC insulated copper conductor single core cable etc as required.
144Supplying and fixing following modules swithch/ socket on the existing modules plate & switch box including connections but excluding modules plate etc as required. (A) 15/16 amp switch
145(b) 5 pin 5/6 amp socket outlet
146(c) 5 pin 15/16 amp socket outlet
147(d) 2 way 5/6 amps switch
148(e)Bell push
149Supplying and fixing following size / modules GI box alongwith modules base & cover plat for modular swithes in recess etc as required. (a) 01 or 2 module (75mm x 75 mm)
150(b) 3 modules (100mmx75 mm)
151(c) 4 modules (125mmx75 mm)
152(d) 6 modules (200mmx75 mm)
153Supplying and fixing cal bell suitable for single phase 230 volts complete as required.
154Suplying and fixing 3 pin 5amp ceiling rose on the existing junction box/ etc as required.
155Earthing with GI earth plate 600mmx600mmx3mm thich including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc with charcal / coke and salt as required.
156Providing and fixing 25mm x 5mm GI strip on surface or in recess for connection etc as required.
157Supplying and fixing PVC batten / angle holder incl connection as reqd complete all as specified and directed.
158Supplying and fixing following way single pole and neutral, sheet steel MCB distribution board 240 valts on surface / recess complete, with finnel copper bus bar, neutral bus bar, earth bar, din bar, inter connection power ponted including earthing etc as rquired (But with out MCB/ RCCB/ ISOLATER) (a) 2+12 way double door
159supplying and fixing horizontal type three pole and nuteral, sheet steel MCCBditributio board, 415 V, on surface / recess, complete with 200 Amp tinned copper busbar, nutral busbar link, earthabar, dinbar, inter connection between incomer MCCB and busbar powder painter incl earthing etc. as required of size 8 way (4+24) double door
160S & F MCCB Triple pole, 160 A, 415 V, 50 HZ with rupturing capacity 16 KA.
161All as srl item No 2.19 here in before but 40 to 63 amps capacity and double pole type.
162S&F in replacement of MCB "C" Curve type, 10 Ka, 10 to 32 amp, single pole with lover load and short circuit protection complete all as directed.
163Wiring for circuit / submain wiring along earth wire with the 2x2.5 sqm+1x2.5 sqm earth wire of FRPVC insulated copper conductor, single core cable in casing caping as required.
164Wiring for circuit / submain wiring along earth wire with the 2x4 sqm+1x4 sqm earth wire of FRPVC insulated copper conductor, single core cable in casing caping as required.
165Fixing only pre-wired light fittings of LED/ flurecent / compact fluoverscent fittting with all accessories on ceiling / wall including connection with 1.5 sqm FR PVC insulated, coppr inductor, single core cable and earthing etc as required all as specified and directed. Note : Light fittings will be under Sch "B" Store.
166Fixing only exhaust fan of any sweep / type including making all electric connection complete all as specified and directed. Note : Exhaust fan will be issued under Sch "B" Store.
167SCHEDULE ‘A’ PART-III (SCHEDULE OF ITEMS) SPECIAL REPAIRS TO 01 NO SINGLE MEN BARRACK BUILDING NO AR-14 (G+I) OF ARASU HAPPY VALLEY, SHILLONG
168Dismantling doorswindows and ventilator (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below.
169Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
170Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
171Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
172Providing and fixing 35 mm thickwire gauge shutters using galvanized wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws with ISI marked M.S. pressed butt hinges bright finished of required size with hollock wood.
173Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
174Providing and fixing 30 mm thickwire gauge shutters using galvanized wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws with ISI marked M.S. pressed butt hinges bright finished of required size with hollock wood.
175Providing and fixing fly proof galvanized wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 2nd class teak wood beading.
176Renewing float glass panes of thickness 4 mm, with putty and nails wherever necessary including racking out the old putty.
177Providing and fixing stainless steel tower bolts 200x10 mm, ISI marked, anodised with necessary screws etc. complete.
178Providing and fixing stainless steel tower bolts 100x10 mm, ISI marked, anodised with necessary screws etc. complete.
179Providing and fixing stainless steel handles 125 mm, ISI marked, anodised with necessary screws etc. complete.
180Providing and fixing stainless steel sliding door bolts 300x16 mm, ISI marked with nuts and screws etc. complete.
181Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead with cement mortar 1:4 (1 cement : 4 fine sand).
182Providing and fixing 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door.
183Two coats distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification including preparing the surface smooth by scrapping, sand paperingincluding necessary repairs to scratches etc. complete.
184Painting with synthetic enamel paint of approved brand and manufacture to give an even shade with two or more coats on new work
185Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface including preparing the surface smooth by scrapping, sand paperingincluding necessary repairs to scratches etc. complete.
186Demolishing cement concrete 1:3:6 or richer mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
187Dismantling old plaster or skirting raking out joints as in roof surfaces and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
188Grading roof for water proofing treatment withCement mortar 1:3 (1 cement : 3 coarse sand) cum
189Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147.The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
190Providing and fixing M.S. stays and clamps for PVCpipes of diameter :100 mm
191Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
192providing12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)
193Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing andeinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
194FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
195Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more.
196Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the anufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
197Providing and fixing on wall face unplasticised Rigid PVC water pipes 110 mm diameter, Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
198Providing and fixing on wall face unplasticised - PVC moulded Single tee with door 110x110x110 mm for unplasticised Rigid PVC water pipes Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
199Half brick masonry with common burnt clay F.P.S. (non modular) bricks with cement mortar 1:4 (1 cement :4 coarse sand) of class designation 7.5.
200Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete25 mm diameter.
201E&M Portion M&L for wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit for caping -N - Casing with and including modular switch, suitable GI box and earthing the point with 1.5 sqm FR PVC insulated copper conductor single core cable etc as required all as specified and directed (Group A)
202M&L for wiring for twin control light point with 1.5 sqm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit or caping - N- casing including 2 way modular swithc, modular plate, suitable GI Box and earthing the point with 1.5 sqm.m FR PVC insulated copper conductor single core cable etc as required.
203Supplying and fixing following modules swithch/ socket on the existing modules plate & switch box including connections but excluding modules plate etc as required. (A) 15/16 amp switch
204(b) 5 pin 5/6 amp socket outlet
205(c) 5 pin 15/16 amp socket outlet
206(d) 2 way 5/6 amps switch
207(e)Bell push
208Supplying and fixing following size / modules GI box alongwith modules base & cover plat for modular swithes in recess etc as required. (a) 01 or 2 module (75mm x 75 mm)
209(b) 3 modules (100mmx75 mm)
210(c) 4 modules (125mmx75 mm)
211(d) 6 modules (200mmx75 mm)
212Supplying and fixing cal bell suitable for single phase 230 volts complete as required.
213Suplying and fixing 3 pin 5amp ceiling rose on the existing junction box/ etc as required.
214Earthing with GI earth plate 600mmx600mmx3mm thich including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc with charcal / coke and salt as required.
215Providing and fixing 25mm x 5mm GI strip on surface or in recess for connection etc as required.
216Supplying and fixing PVC batten / angle holder incl connection as reqd complete all as specified and directed.
217Supplying and fixing following way single pole and neutral, sheet steel MCB distribution board 240 valts on surface / recess complete, with finnel copper bus bar, neutral bus bar, earth bar, din bar, inter connection power ponted including earthing etc as rquired (But with out MCB/ RCCB/ ISOLATER) (a) 8 way double door
218supplying and fixing horizontal type three pole and nuteral, sheet steel MCCBditributio board, 415 V, on surface / recess, complete with 200 Amp tinned copper busbar, nutral busbar link, earthabar, dinbar, inter connection between incomer MCCB and busbar powder painter incl earthing etc. as required of size 8 way (4+24) double door
219supplying and fixing horizontal type three pole and nuteral, sheet steel MCCBditributio board, 415 V, on surface / recess, complete with 200 Amp tinned copper busbar, nutral busbar link, earthabar, dinbar, inter connection between incomer MCCB and busbar powder painter incl earthing etc. as required of size 12 way (4+36) double door
220supplying and fixing horizontal type three pole and nuteral, sheet steel MCCBditributio board, 415 V, on surface / recess, complete with 200 Amp tinned copper busbar, nutral busbar link, earthabar, dinbar, inter connection between incomer MCCB and busbar powder painter incl earthing etc. as required of size 4 way (4+12) double door
221S & F MCCB Triple pole, 250 A, 415 V, 50 HZ with rupturing capacity 35 KA.
222S & F MCCB Triple pole, 160 A, 415 V, 50 HZ with rupturing capacity 16 KA.
223S & F MCCB Triple pole, 100 A, 415 V, 50 HZ with rupturing capacity 16 KA.
224S&F in replacement of MCB "C" Curve type, 10 Ka, 10 to 32 amp, single pole with lover load and short circuit protection complete all as directed.
225All as srl item No 2.24 here in before but 40 to 63 amps capacity and double pole type.
226Wiring for circuit / submain wiring along earth wire with the 2x2.5 sqm+1x2.5 sqm earth wire of FRPVC insulated copper conductor, single core cable in casing caping as required.
227Wiring for circuit / submain wiring along earth wire with the 2x4 sqm+1x4 sqm earth wire of FRPVC insulated copper conductor, single core cable in casing caping as required.
228Fixing only pre-wired light fittings of LED/ flurecent / compact fluoverscent fittting with all accessories on ceiling / wall including connection with 1.5 sqm FR PVC insulated, coppr inductor, single core cable and earthing etc as required all as specified and directed. Note : Light fittings will be under Sch "B" Store.
229Fixing only exhaust fan of any sweep / type including making all electric connection complete all as specified and directed. Note : Exhaust fan will be issued under Sch "B" Store.
230SCHEDULE ‘A’ PART-IV (SCHEDULE OF CREDIT)
231SCHEDULE ‘A’ PART-I UNSV Wooden Vent (Rate should be quoted Rs 235.00 per Nos or more)
232UNSV Steel Door frame (Rate should be quoted Rs 295.00 per Nos or more)
233UNSV Steel windows frame with shutter (Rate should be quoted Rs 346.00 per Nos or more)
234UNSV Wooden door wire gauge shutter (Rate should be quoted Rs 254.00 per Nos or more)
235UNSV Wooden paneled door shutter (Rate should be quoted Rs 136.00 per Nos or more)
236UNSV CP bib Taps 15 mm (Rate should be quoted Rs 25.00 per Nos or more)
237UNSV CP Brass Angle Valves 15 mm (Rate should be quoted Rs 36.00 per Nos or more)
238UNSV GI Pipe 15 mm (Rate should be quoted Rs 12.00 per Mtr or more)
239SCHEDULE ‘A’ PART-II UNSV Wooden Vent (Rate should be quoted Rs 235.00 per Nos or more)
240UNSV Steel Door frame (Rate should be quoted Rs 295.00 per Nos or more)
241UNSV Steel windows frame with shutter (Rate should be quoted Rs 346.00 per Nos or more)
242UNSV Wooden door wire gauge shutter (Rate should be quoted Rs 254.00 per Nos or more)
243UNSV Wooden paneled door shutter (Rate should be quoted Rs 136.00 per Nos or more)
244UNSV CP bib Taps 15 mm (Rate should be quoted Rs 25.00 per Nos or more)
245UNSV CP Brass Angle Valves 15 mm (Rate should be quoted Rs 36.00 per Nos or more)
246UNSV Aluminium cable 1.5 sqmm (Rate should be quoted Rs 3.00 per Mtr or more)
247UNSV Batten Holder (Rate should be quoted Rs 2.5 per Nos or more)
248UNSV GI Pipe 15 mm (Rate should be quoted Rs 12.00 per Mtr or more)
249SCHEDULE ‘A’ PART-III UNSV Door shutter UNSV (Rate should be quoted Rs 400.00 per Nos or more)
250UNSV Door Shutter UNSV (fly proof) (Rate should be quoted Rs 200.00 per Nos or more)
251OldUNSVscrapretrieved from B&R stores (Rate should be quoted Rs 22000.00 per Job or more)