| 1 | Removing of mangalore damaged tiles in cement mortar including all tools with labour charges etc., complete as per standard specification |
| 2 | Dismantling plain cement concrete, clearing away and carefully stacking materials useful for reuse for any thickness of walls |
| 3 | Supplying, fabricating and placing in position M.S. or R.T.S. reinforcements grill for RCC works as per the design given including cost of steel and binding wire etc., complete complying with standard specification. (The contractor will have to make his own arrangements for the supply of M.S. plain rods / RTS rods and binding wire) |
| 4 | Earthwork open excavation in all soils and sub soils and to full depth as may be directed except in rock requiring blasting but inclusive of shoring, strutting and baling out water wherever necessary and depositing the excavated earth within the compound in places shown by departmental officers with an initial lead of 10m and lift of 2m and clearing and leveling etc., for pipeline work complete as per standard specification. |
| 5 | Plain Cement concrete 1:4:8 (one cement, four sand and Eight stone jelly) using 40mm gauge hard broken granite stone jelly for flooring including consolidating as per standard specification, rendering the top rough to take the floor finish and curing etc., complete and complying with standard specification. |
| 6 | Reinforced Cement Concrete 1:1½:3 (One cement, one and half sand and three stone jelly) using 20 mm gauge hard granite broken stone jelly for all reinforced cement concrete works excluding cost of reinforcement grill and fabricating charges, centering and shuttering but including laying, vibrating with mechanical vibrator, finishing, curing, etc.complete as directed by the Departmental Officers |
| 7 | Brick work in CM 1:5 (one cement & five sand) using Fly Ash bricks size of 230x110x70mm including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 8 | Plastering with Cement Mortar 1:5 (One cement and Five sand), 12 mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 9 | Supplying and fixing RCC Pre cast slab in RCC 1:1 1/2:3 mix including cost of reinforcement grill but including moduling, finishing watering curing and fixing in position etc., Complete as per std., Specifications., |
| 10 | Paving the floor with descrigned coloured Vitrified tiles of size 600 x 600 x 8mm of best quality and approved variety complying / confirming ISI specification land over cement mortar 1:3 (one cement and three sand) 20mm thick and pomted with same coloured cement neatly etc., complete. |
| 11 | Laying with new C.C. Laminated tiles (Like Dora tiles Eurocon tiles etc),(anti skid) of 20mm thick of approved spl quality and set in Cement Mortar 1:3 (1 of cement and 3 of sand ) 20mm. Thick using river sand and pointing with colour cement using at the rate of 0.40 kg/M2 and mixing with colour pigment at the rate of 0.3 Kg/M2 including finishing complete with Standard Specification and as directed by the Departmental Officers etc., |
| 12 | Supplying and fixing of M.S grill of approved design for doors, windows and ventilators using necessary mild steel flats for inner and outer memebers which should be fixed to window frames inclusive of priming coat of best approved quality red oxide primer etc., complete complying with standard specifications. |
| 13 | Supply and fixing of best tiled roofing with Mangalore tiles over celing tiles of best quality with standard specification etc.., complete. |
| 14 | Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC.unsheathed Cu. Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A F.T. switch with painting of suitable Colourfor open PVC light point / fan point SD-18 |
| 15 | Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 mm x 100 mm x 113mm TW switch box in flush with wall with 3 mm thick Hylem sheet cover for 5 A 3 pin non inter locking Wall socket with 5A Flush type switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC plug point. SD-37 |
| 16 | Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15 A 3 pin non inter locking Wall socket with 15A Flush type switch with continuous earth wire connection of 14 SWG TC wire , and making good of the concealed portion, with suitable colour for concealed power plug point SD-41 |
| 17 | Wiring with 2 x 1.5 sqmm (22/0.3) PVC insulated unsheathed Sc Cu.Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch inflush with wall, covered with hylem sheet of 3mm thick with painting of suitable colour for open PVC light point / fan point SD-21 |
| 18 | Supply and fixing of single box type 4\"36 W flu fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting.SD-87 |
| 19 | Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Crompton / K. Lite) suitable for11W CFL lamp with CFL.SD-83 |
| 20 | Supply and fixing 1400 mm (56\") sweep AC ceiling fan complete with stepped electronic 300W regulator with the existing down rod on the existing clamps.SD-113 |
| 21 | Exterior Emulsion paint Two coats with good quality of approved Emulsion paint including cost of all materials to site and all labour charges for mixing applying and proper curring etc., Complete as per Standard Specifications |
| 22 | Painting one coats over the old iron work using ready mixed enamel paint including cost of all materials to site and all labour charges for mixing applying etc., Complete as per Standard Specifications |
| 23 | Providing and laying of 80mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver block in required sizes of minimum compressive strength of 40 N/mm2 in uniform shape of approved make to be laid in flurrying bone pattern with approved non sticking surface in the top and the rate including leveling the base preparation of sub base with stone dust cushion 100mm thick, laying out the pavement cut the pieces to fit the edge, vibrating the pavers, sweeping transporting, loading unloading and laying of paver block as per standard specification. |