Tender For Addition Alteration In Dc Residence Mansa, mansa-Punjab

Public Works Department-PWD has published Tender For Addition Alteration In Dc Residence Mansa. Submission Date for this Tender is 21-02-2024. Building Work Tenders in mansa Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41843510
Corrigendum : Tender For Addition Alteration In Dc Residence Mansa
Open Tender
Indian
Punjab
mansa
21-02-2024

Tender Details

Addition Alteration In Dc Residence Mansa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Feb-2024 Corrigendum1 Date 16-02-2024
2 16-Feb-2024 Corrigendum2 Date 21-02-2024

Key Value

Document Fees
INR 5000 /-
EMD
INR 62250.0 /-
Tender Value
INR 31.12 Lakhs /-

BOQ Items

Name of Work:Addition/Alteration in DC Resdience, Mansa.
Sl. No. Item Description
1Dismantling of pre-stressed / RCC including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 mtr (By Mechanical Means)
2Dismantling brick work tile masonary or tile lining.In cement.
3Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.Doors of area 3 sqm and below
4Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.Windows of area 3 sqm and below
5Dismantling cement conglomerate floors 25mm to 50mm thick without concrete base
6Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type
7First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
8First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
912.5 mm thick cement plaster 1:4
10Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.
11Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
12Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
13Extra for Smooth exposed concrete finish is desired and plaster is not to be done.
14Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
15Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
16Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
17Providing and Fixing ceiling at height upto 4 mtr consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge.
18Sal wood chowkats including iron hold fasts iron hinges corner straps clears, stops wooden knobs fixed in position. Double Rebate (60mm x 150mm)
19Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1(1999) ) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
20Imported Teak Wood doors shutter windows shutter including hinges, screw and cords etc. Complete fixed in position Panelled, glazed or glazed and panelled. 35mm thick
21Wire Gauge Imported teak wood door shutter without springs housed in chowkats.. 35mm thick
22Providing and Fixing Single Glazing with 6mm thick glass with high perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge.
23Providing & fixing of Collapsible Mosquito/Insect Mesh/ Fiber Pleated Insect Screen/Mesh fixing in 18 mm Aluminium Channels 3mm thickness of Channel with Powder Coated and Nylon Accessories complete in all respect as per the directions of Engineer-in-charge.
24Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer"s specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
25Providing & fixing 30mm thick factory made Hollow PVC Profile PVC Flush door shutter consisting of panel of of 20mm thickness,frame made out of M.S. tubes of size of 19mm x 19mm x19 guage inserted inside the hollow section of stiles, top and bottom rails and two 19mm x 19mm MS tubes inserted horizontally inside the hollow profile section using 5mm thick PVC sheet using screws. Hollow PVC profile shall be lipped with 10mm (5mm x 2) thick x 20mm width on stiles and rails using solvent cement. the inner panel shall be laminated with 5mm thick termite proof, water proof and fire retardant Prelam PVC sheet using solvent cement on both the sides of panel etc. complete as per manufacturer"s specification, conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
26Providing and fixing commercial plywood 18mm thick
27Providing & Fixing decorative high pressure laminated sheet 1mm SF thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
28Providing & Fixing decorative laminated sheet 0.72mm thick and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
29Providing & fixing 2"-6" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
30Providing & fixing1"-6" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
31Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
32Providing & fixing 2" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
33Providing & fixing 6" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
34Scraping of Cement plaster
3512.5 mm thick cement plaster 1:4
36Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish.
37Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
38Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
39Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint
40Stripping and stacking slate or tiles of a roof.
41Credit of Old dismantled tiles from roof
42Credit of Old dismantled tiles Bats from roof
43Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
44Credit of Old Material Steel
45Credit of Old Material Brick
46Credit of Old Material Brick Bats
47Credit of Old Material Door
48Credit of Old Material Window
49First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level.
50Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
51Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
52Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
53Base course of floor consisting of 100 mm thick CC 1:8:16 with stone aggrigate 40 mm guage and 100mm fine Sand filling using machenical mixer for mixing material
54Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600x1200 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
55Kotah stone rough dressed 40mm to 50mm thick slabs, set to pattern in pavements over 20mm thick base of cement mortar (1 cement, 3 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone
56Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
57Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. Size 600x600 mm
58Providing Fixing Exuast fan complete in all respects 12"x12" made of PVC complete with luver and Fixing
59Construction of Foundation for Water storage Tank of Brick Work and C.C.
60Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 110 mm o/d pipes (for External sewar pipe )
61ProvidingandfixinginpositionSWRUPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval ofEngineer-in-charge)includingcutting, jointing,wastage,butexcludingcostoflead jointing. Type B 110 mm o/d SWR UPVC pipe line laid complete
62ProvidingandfixinginpositionSWRUPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval ofEngineer-in-charge)includingcutting, jointing,wastage,butexcludingcostoflead jointing. Type B 90 mm o/d SWR UPVC pipe line laid complete
63ProvidingandfixinginpositionSWRUPVC specials for soil waste vent or anti syphonage pipesasperasperIS-14735ofapproved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making goodtoitsoriginalconditionbutexcluding cost of lead joining. For 110 mm o/d pipes Elbow 90 degree (all side socket)
64ProvidingandfixinginpositionSWRUPVC specials for soil waste vent or anti syphonage pipesasperasperIS-14735ofapproved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making goodtoitsoriginalconditionbutexcluding cost of lead joining. For 110 mm o/d pipes Coupler
65ProvidingandfixinginpositionSWRUPVC specials for soil waste vent or anti syphonage pipesasperasperIS-14735ofapproved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making goodtoitsoriginalconditionbutexcluding cost of lead joining. For 110 mm o/d pipes Single Tee
66ProvidingandfixinginpositionSWRUPVC specials for soil waste vent or anti syphonage pipesasperasperIS-14735ofapproved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making goodtoitsoriginalconditionbutexcluding cost of lead joining. For 110 mm o/d pipes P Trap/Floor Trap 110mm x 110mm
67ProvidingandfixinginpositionSWRUPVC specials for soil waste vent or anti syphonage pipesasperasperIS-14735ofapproved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making goodtoitsoriginalconditionbutexcluding cost of lead joining. For 110 mm o/d pipes Nahani trap without jali 110mmx90mm
68ProvidingandfixinginpositionSWRUPVC specials for soil waste vent or anti syphonage pipesasperasperIS-14735ofapproved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making goodtoitsoriginalconditionbutexcluding cost of lead joining. For 90 mm o/d pipes Elbow 90 degree (all side socket)
69ProvidingandfixinginpositionSWRUPVC specials for soil waste vent or anti syphonage pipesasperasperIS-14735ofapproved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making goodtoitsoriginalconditionbutexcluding cost of lead joining. For 90 mm o/d pipes Single Tee
70Providingandfixinginpositiongullytraps fixed in cement concrete 1:4:8 complete with Grating 150 mm x 150 mm , cover and frame clear opening 300 mmx 300 mm and out of sidesize330mmx330mmandchamber includingcostofallbricksworkincement mortar1:5cementconcrete1:2:4incoping around cover and frame etc. as per standard designminimumdepthofwatershouldbe 150 mm with a minimum seal 50 mm. 100mminternalDiameterS.W.Gullytrap with H.C.I. grating and cast iron cover weighingapproximately7.26kg.andframe clear opening 300 mmx 300 mm and out of side size 330 mm x 330 mm
71Construction of brick masonry inspection chamberssizeasgivenbelowupto0.60 metreaveragedepthin1:5cementsand mortar,limeconcretewith40percentlime mortar2:3infoundation,cementconcrete 1:2:4 benching 12.50 mm thick cement plaster 1:2 with a floating coat of 1 mm thick ofneatcement,R.C.C.1:2:4slabs100mm thickcementconcretetopping50mmthick with455mmx455mm,455mmx610mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. Size450 mmx450 mminsidewithRCC 455 mmx455 mmcoverandframelight duty double seal
72CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 Pipe & fitting 16mm o/d
73SDR 11 CPVC pipes & fittings 20mm o/d
74INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. SDR 11 CPVC pipes & fittings 25mm o/d
75Cuttingchaseinbrickwallsincementorin floor for embedding G.I. or C.I pipes line and makinggoodthesame to its original condition. Size 75 mm x 75 mm
76Cuttingholesupto23cmsquarethrough B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required. Through wall 11.43cm thick
77Through wall 22.86cm thick
78Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
79Providing and fixing in position concealed cistern including flushing plate of approved make (to the approval of the Engineer-in charge) complete in all respect.
80Providingandfixingjetspraywith2"-6"long PVC pipe with PTMT nut
81Providing &FixinginpositionC.P.Brass Hexa Nipple 15 mm of approved make (to the approvalofEngineer-in-charge)completein all respect.
82Providing and fixing in position vitreous chinawarewhitelavatorysuitesofapproved make (to the approval of Engineer-in-charge) consistingofC.P.brasswaste32mmdia with one C.P. brass pillar tap complete in all respect. Table Top round (size 40.5 x 40.5 x 14 cm)
83Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 450mm with CP Brass nut
84Providing and fixing PVC waste pipe 32 mm i/dofapprovedmake(totheapprovalof Engineer-in-charge) complete in all respect.
85Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect C.P. Brass fittings: C.P.brass 15mm Angular stop cock with Wall flange
86C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)For Jet Spray+Concealed Cistern
87C.P. brass 3-Hole Basin Mixer Without Popup Waste System
88C.P. brass overhead shower F180mm round shape single flow with shower arm with 20mm i/d Inlet and 300mm long round shape with 900 bend with flange.
89C.P brass Sink mixer with swinging spout.(wall mounted)
90C.P brass Sink mixer with regular spout table mounted with 450mm long flexible hose
91Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect C.P. Brass Accessories: C.P brass towel ring square
92C.P. brass soap dish holder with glass dish
93C.P. brass toilet roll holder with flap
94C.P. brass towel rack 600mm long with lower hangers
95Providing and fixing divertors of approved make (to the approval of Engineer-in-charge ) for bath and shower system complete in all respect. Single lever concealed divertor for bath and shower system (3 inlet flow) with body and upper part
96Providing &FixinginpositionC.P.Brass extension piece 25 mm long to 50 mm long of approved make (to the approval of Engineer- in-charge) with various fixtures complete in all respect.
97Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge)withcoverwithsuitablelocking arrangement and making necessary holes for inlet,outletandoverflowpipesbutwithout fittingsandbasesupportfortank- Triple Layer Tanks
98Providing and fixing in position automatic brass Ball Cock in tanks. BrassBallCockwithrodandPlasticBall 25mm i/d
99Providing andfixing inpositionG.I.Tank Nipple ofapproved make (to the approval of Engineer-in-charge)inPVCWaterstorage tanks complete in all respect. G.I. tank nipple 25 mm i/d
100Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
101Providing & Fixing in position mirror of superior glass Size 1500mm x600mm or any other required size (of approved quality) and of required shape and size with high quality polystyrene moulding frame of 40 to 50mm size (of approved quality and shade) with 4mm thick hardboard backing fixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect
102Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. Vertical type 25 litre capacity water heater
103Providing and installing in position of domestic water pressure boosting pump of approved make (To the approval of Engineerin- charge) including all pump accessaries but excluding cost of G.I pipe & specials complete in all respects. Pressure pump of 0.5 HP with 2700 LPH, 35meter head with C.I pump & 19 litre capacity Tank
104Providing and installation of 4.5 kw steam genrator of reputed make ISIwith indoor touch pad unit including fitting oftoughened glass (12 mm )thick cabin size 4"x4"x7" and sitting woodentable complete with accessory after the approval of engineer in charge.
105Providing and Fixing of Bath Tub complete with accessories of premium range like grab bar, flexible shower, Mixture, CP waste complete.
106Carriage of material:- Fine Sand (For 164 km)
107Carriage of material:- Ghaggar Sand(For 0 - 300 km)
108Carriage of material:- Ghaggar Sand(For 300 - 314 km)
109Carriage of material:- Ghaggar Sand(For 0 - 300 km)
110Carriage of material:- Ghaggar Sand(For 300 - 314 km)
111RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point)and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (With fan box)
112Wiring light point
113Wiring 6Amp. wall socket point
114Wiring 6Amp. Plug control comprising wall socket point
115Wiring 16/20Amp. power plug control point
116RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) andmodular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring AC supply terminal point having1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
117SURFACE COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPEWIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points on surface on wall etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate, covered with Frame Plate etc., & including the cost of above material and other petty material with necessary connections etc.:- Wiring Computer terminal point having 2 Nos. 6Amp. 2/3 universalsocket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indiicator
118Supply and erection of PVC insulated FR singlecoreUnsheathedcopper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitablesize completein all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed)
119Overall size 4sq.mm (Un-sheathed)
120XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 10sq.mm (2Core) Un-armoured (On-Surface)
121Overall size 25sq.mm (3½ Core) Un-armoured (On-Surface)
122Overall size 35sq.mm (3½ Core) Un-armoured (On-Surface)
123Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
124Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materialsetc., as per PWD General Specifications:- Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
125Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- Ceiling Rose (Flush Piano type)
126Bakelite Batten Holder (Large size)
127Supply and erection of Miniature Circuit Breaker MCB"s for circuit protection againstoverloadandshortcircuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitationclass-3,truecontact indication, label holder facility in the existing MCB distribution board as per PWD General Specificationsincluding connectionswithsuitablesize of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C)
128MCB Double Pole 6-32amp. (10kA, Curve-C)
129MCB Double Pole 40amp. (10kA, Curve-C)
130MCB Four Pole 40amp. (10kA, Curve-C)
131MCB Four Pole 50, 63amp. (10kA, Curve-C)
132SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS):Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. oftin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bondingto the existing earth and painting etc. as desired by the Engineer-in-charge at site:- Bus Bar Chamber 100amp., 415volts Overall Dimensions (300mm x 345mm x 120mm) nominal
133SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB"s/ RCBO"s/ RCCB"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mountingminiature circuit breakers/ RCBO"s/ RCCB"s in the distribution board (For SP&Ndistribution board with provision DP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings and for TP&Nhorizontal distribution board with provision TPN/ FP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- SP&N Double Door Distribution Board 4 way each
134TP&N Horizontal Double Door Distribution Board 8 way each
135ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure): Supply and erection ofOn Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch withsuitablesizeofthimblesasper PWD General Specifications:- On Load Change Over Switch Four Pole 63amp., 415volts (With Sheet Enclosure)
136OnLoadChangeOverSwitchFourPole 100amp., 415volts (With Sheet Enclosure)
137SWITCH DISCONNECTOR FUSE UNIT (With Sheet Enclosure):Supply and erection of Switch Disconnector Fuse Unit with HRC Fuses (Suitable for DIN HRC Fuses) in sheet enclosure on the existing surface Confirms to IS 13947 (Part-III), IEC 60947-3 complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles, including cost of DIN HRC fuses as per PWD General Specifications:- SDF TP&N 63Amp., 415volts (With Sheet Enclosure)
138SDF TP&N 100Amp., 415volts (With Sheet Enclosure)
139SupplyanderectionofSMCJunction Box (Glass Fibre reinforced polyester sheet moulding compound)confirm to IS:14772(Recessed/Onsurface), robustlyconstructed,safe&shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangementhaving 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB"s)complete in allrespect as approved and desired by the Engineer In-Charge at site:- SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirmto IS:14772, inner dimensions 200mmx140mmx95mmwithhinged water tight cover with locking arrangement
140COPPER EARTHING:8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
141Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
142Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound)confirming to IS:14772, inner dimensions 250mm x 200mm x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB"s). The SMC Junction Box is to be fixedwith the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement & two coats of whitesnowcem complete in allrespect as approved and desired by the Engineer In-Charge at site:- Cement Concrete Muff of Overall Size 450mm dia., 80cm Long
143LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS: Labour for dismantling G.I. pipe pole upto length 6.1 m.
144Erection of G.I. Pipe/ 3-Stepped Steel tubular pole in suitable planting depth below ground level in a hole ofexcavation and suitable depth to filled in up to 15 cm below G/L with 1:2:4 cement concrete mixture but excluding cost of pole including two coats of approved aluminium paint etc:- Erection of G.I. pipe pole upto 6 m length (hole ofexcavation about 30 cm dia.)
145Painting of Galvanized iron pipe pole including bracket with two coats of aluminium paint (With brush):- Overall Length 6.1 Metre
146Supply and erection of LED batten 20 Watt LED (including constant LED driver) withHigh quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per wattand operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) serge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary.
147Supply and Erection of LED Flood Light 50 Watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Hon"ble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have in house NABL accredited LAB.
148Supply and erection of Wall Fan Plastic Body 300MM, 12" including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site.
149Supply and erection of Recessed Mounted 36 Watt LED 2x2 panel (including constant LED driver) withHigh quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per wattand operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary.
150Supply and erection of Slim Recessed mounted, Round downlighter 18 watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with CRCA sheet with control gear (IP 20 protection), THD<10%, CRI minimum 70,Low power LED with wattage Less 1 Watt, Surge Protection 2.5KV and above as per IS/ IEC Standards, efficacy of LED fixture minimum 100 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon"ble Technical Advisor to Punjab Govt. vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
151Supply and erection of 3- star rating AC Ceiling Fan 1200mm (48") Suitable for 230 V single with double ball bearing, copper wound, full aluminium body, 3No. Of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delivery of 218 CMM. The rated speed of the product must be minimum of 350 revolutions per minutes and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufacture"s guarantee/warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfication of the Engineer in-charge at site.
152Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver)with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70,High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon"ble Technical Advisor to Punjab Govt. vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
153S/E of Decorative Post top LED 20/25 Watt, opal diffuser (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Hon"ble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fiture manufacturer should have in house NABL accredited LAB.
154Supply & Installation of LED Strip Light (5 Mtr ) including Driver connection & testing charges etc. Complete in all respect as per entire satisfaction of the Engineer In Charge.
155Supply and erection of LED COB Light 6W Recessed mounted, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with CRCA sheet with control gear (IP 20 protection), THD<10%, CRI minimum 70,Low power LED with wattage Less 1 Watt, Surge Protection 2.5KV and above as per IS/ IEC Standards, efficacy of LED fixture minimum 100 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon"ble Technical Advisor to Punjab Govt. vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
156Less Cost of Old Material
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail