Tender For Procurement Of Fire Alarm And Public Addressing System For Iit Jagti And Paloura Campus., jammu-Jammu And Kashmir

Indian Institute Of Technology-IITB has published Tender For Procurement Of Fire Alarm And Public Addressing System For Iit Jagti And Paloura Campus.. Submission Date for this Tender is 15-02-2024. Alarm Systems Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41835353
Tender For Procurement Of Fire Alarm And Public Addressing System For Iit Jagti And Paloura Campus.
Open Tender
Indian
Jammu And Kashmir
jammu
15-02-2024

Tender Details

Tender For Procurement Of Fire Alarm And Public Addressing System For Iit Jagti And Paloura Campus. , Main Item - Fire Alarm System ( As Per Technical Specifications Mentioned At Point 4 And Warranty As Per Schedule Of The Tender Document ) , Addressable 2 Loop Fire Alarm Control Panel ( Facp ) With Battery Back Up For 48 Hours Normal Operation And 30 Minutes Alarm Operation. It Shall Include A Full Featured Operator Interface Control And Annunciation Panel Having Liquid Crystal Display, Individual Color Coded System Showing The Status Through Leds, And A Alphanumeric Keypad For The Field Programming And Control Of The Fire Alarm System. The Panel Including Enclosure Shall Be Ul Listed Complying To Ul 864, 10Th Edition Requirement And Fm Approved. If The Panel Programming Requires A Dongle / Key Then The Same Shall Be Supplied Along With The Panel. , Analogue Addressable Flash Scan Multi-Sensing, Low-Profile Detector ( Acclimate Type ) Having Rotary, Decimal Addressing System With Standard Base, Junction Box And Other Accessories As Required. The Detector Shall Be With Visible Bi- Color Leds For 360 Deg Viewing And Shall Blink Green Every Time The Detector Is Addressed, And Illuminate Steady Red On Alarm. Detector Shall Comply Ul 268, 7Th Edition Requirements , Heat Detector- Operating Voltage: 17 To 41 Vdc Current Consumption: Standby: .55 Ma Alarm: .55 Ma Detection Temperature Range: 135°F To 150°F ( 57°C To 65°C ) Ambient Temperature: 32ºf To 120ºf ( 0ºc To 49ºc ) Mounting: 4 Sqr, 4 Oct Single Gang Mud Ring Rated Spacing: 70’ Between Sensors On Smooth Ceilings. , Analogue Addressable Fault Isolator Module Capable Of Monitoring Shorted Loop Circuit And Automatically Restore Communications When Shorted Conditions Are Corrected. Module Shall Be With Back Box, Led Indication And Other Accessories All Complete As Required. It Shall Work On Suitable Dc Voltage. , Addressable Hooter Cum Strobe Unit As Per Nfpa Shall Deliver Ouput Up To 90 Db At 1 M From Source ( Adjustable At Site Or From The Panel ) And Candela Setting From 15 To 130 Cd From Its Installed Location And 75Cd Flashing At 1 Hz For Visual Indication. No External 3Rd Party Power Supply Shall Be Permitted. Vendor To Include All Accessories. , Addressable Manual Pull Stations Or Manual Call Point ( Mcp ) Of Single Action Type With An Integrally Mounted Addressable Module That Monitors And Reports Contact Status. , Analogue Addressable Control Module Having Rotary, Decimal Addressing System And Shall Be Capable Of Providing Dpdt Contact Rated At 24V Dc, 2A , Addressable Power Supply Unit With Battery Backup For Hooters With Suitable Ms Enclosure , Main Item - Cable & Accessories ( As Per Technical Specifications Mentioned At Point 4 And Warranty As Per Schedule Of The Tender Document ) , 2C X 1.5 Sq. Mm, Pvc Insulated Frls Copper Armored Conductor Multi Core Cables. , 4 Modules Back Box For Installing The Detectors, Mcp, And Hooters , Glands For The Detector Back Box , 2 Inch Frls Casing And Capping Jointing Accessories , 2 Inch Frls Casing And Capping , Main Item - Service - Fas ( As Per Technical Specifications Mentioned At Point 4 And Warranty As Per Schedule Of The Tender Document ) , Supervision, Programming, Drawing Charges, Testing Charges , Main Item - Pa System ( As Per Technical Specifications Mentioned At Point 4 And Warranty As Per Schedule Of The Tender Document ) , Supply, Installation , Testing & Commissioning Of Voice Alarm Controller With Expander / Router Having Features Like Announcement To 12 Zone , Built In 500W , Input Port Of Emergency Microphone On The Front Panel, Music To Selected Zones Can Be Played, Built In 1 Gb Memory For Audio Files, Volume Adjustment With Digital Volume Control. As Per Technical Specification Etc. As Required. , Supply, Installation , Testing & Commissioning Of Voice Alarm Call Station Having Gooseneck Condenser Microphone With 12 Zone Selection Keys And An All-Call- Key, Ptt Switch, Selectable Gain, Speech Filter And Limiter For Improved Intelligibility, Led Indication For Zone Selection Complete As Required, Emergency Microphone Bypass Controller, Incase Of Cpu Failure As Per Technical Specification Etc. As Required. , Supply, Installation, Testing & Commissioning Of 15Watts Wall Mount Speaker With Max Spl1m / 1W 98Db. Frequency Response Of 160Hz-20Khz. The Speaker Should Have Tappings At 15W / 7.5W As Per Technical Specification Etc. As Required. , 500W Amplifier , 2C X 1.5 Sq. Mm, Twisted Pair Pvc Insulated Frls Copper Armored Conductor Multi Core Cables. , Supply And Installation Of 12U Rack For Keeping Controller And Amplifier Setup , Main Item - Services-Pas ( As Per Technical Specifications Mentioned At Point 4 And Warranty As Per Schedule Of The Tender Document ) , Supervision, Programming, Testing And Drawing Preparation Charges

Key Value

Document Fees
Refer document
EMD
INR 208000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Tender for procurement of Fire Alarm and Public Adressing System for IIT Jagti and Paloura Campus
Sl. No. Item Description
1Main Item - Fire Alarm System (as per technical specifications mentioned at point 4 and Warranty as per SCHEDULE of the tender document)
2Addressable 2 Loop Fire Alarm Control panel (FACP) with battery back up for 48 hours normal operation and 30 minutes alarm operation. It shall include a full featured operator interface control and annunciation panel having liquid crystal display, individual color coded system showing the status through LEDs, and a alphanumeric keypad for the field programming and control of the fire alarm system. The panel including enclosure shall be UL listed complying to UL 864, 10th Edition requirement and FM approved. If the panel programming requires a dongle/key then the same shall be supplied along with the panel.
3Analogue Addressable Flash scan multi-sensing, low-profile detector (Acclimate type) having Rotary, decimal addressing system with standard base, junction box and other accessories as required. The detector shall be with Visible bi- color LEDs for 360 deg viewing and shall blink green every time the detector is addressed, and illuminate steady red on alarm. Detector shall comply UL 268, 7th edition requirements
4Heat detector- Operating Voltage: 17 to 41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Detection Temperature Range: 135°F to 150°F (57°C TO 65°C) Ambient Temperature: 32ºF to 120ºF (0ºC to 49ºC) Mounting: 4" SQR, 4" OCT Single gang mud ring Rated Spacing: 70’ between sensors on smooth ceilings.
5Analogue addressable Fault isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected. Module shall be with back box, LED indication and other accessories all complete as required. It shall work on suitable DC voltage.
6Addressable Hooter cum strobe unit as per NFPA shall deliver ouput up to 90 db at 1 m from source (adjustable at site or from the panel) and candela setting from 15 to 130 cd from its installed location and 75cd flashing at 1 Hz for visual indication. No external 3rd party power supply shall be permitted. Vendor to include all accessories.
7Addressable Manual Pull Stations or Manual Call Point (MCP) of Single action type with an integrally mounted addressable module that monitors and reports contact status.
8Analogue Addressable Control module having Rotary, decimal addressing system and shall be capable of providing DPDT contact rated at 24v DC, 2A
9Addressable power supply unit with battery backup for hooters with suitable MS enclosure
10Main Item - Cable & Accessories (as per technical specifications mentioned at point 4 and Warranty as per SCHEDULE of the tender document)
112c x 1.5 sq. mm, PVC insulated FRLS copper armored conductor multi core cables.
124 modules back box for installing the Detectors, MCP, and Hooters
13Glands for the Detector Back Box
142 Inch FRLS Casing and capping Jointing accessories
152 Inch FRLS Casing and capping
16Main Item - Service - FAS (as per technical specifications mentioned at point 4 and Warranty as per SCHEDULE of the tender document)
17Supervision, programming, Drawing charges, Testing charges
18Main Item - PA System (as per technical specifications mentioned at point 4 and Warranty as per SCHEDULE of the tender document)
19Supply, installation ,testing & Commissioning of Voice Alarm Controller with Expander / Router having features like announcement to 12 zone , built in 500W ,input port of emergency microphone on the front panel, music to selected zones can be played, built in 1 GB memory for audio files, volume adjustment with digital volume control. as per technical specification etc. as required.
20Supply, installation ,testing & Commissioning of voice Alarm Call Station having gooseneck condenser Microphone with 12 zone Selection Keys and an All-Call- Key, PTT Switch, selectable gain, speech filter and limiter for improved intelligibility, LED indication for zone selection complete as required, Emergency Microphone bypass controller, incase of CPU failure as per technical specification etc. as required.
21Supply, Installation, Testing & Commissioning of 15Watts Wall Mount speaker with max SPL1M/1W 98dB. Frequency response of 160Hz-20KHz. The speaker should have tappings at 15W/7.5W as per technical specification etc. as Required.
22500W Amplifier
232c x 1.5 sq. mm, twisted pair PVC insulated FRLS copper armored conductor multi core cables.
24Supply and Installation of 12U Rack for Keeping controller and Amplifier setup
25Main Item - Services-PAS (as per technical specifications mentioned at point 4 and Warranty as per SCHEDULE of the tender document)
26Supervision, programming, testing and Drawing preparation Charges
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail