Tender Details

Supply Of C2-Modular Ot-2 Supply And Installation Of Ss 304 Puff Panel , Thickness: 50 Mm. Front Panel Ss -304 Wall Thickness: 1.0 Mm.Back Panel Material Ss 304 , Wall Thickness : 0.8 Mm . Make- Jindal / Tata Steel / Sail ( As Per Technical Specification ) . Antimicrobial Coating: Filling Of All Joints And Cavities With Metallic Epoxy Filler And Sanded Flush To Provide A Jointless Finish. 3 Optional Quote For : Anti Bacterial Epoxy And Anti Fungus Sterile Coating To Be Applied On The Ss-304 Finished Walls And Ceilling With At Least 3-4 Coat To Achieve Dry Film Thickness Of Minimum 200-300 Micron. The Primer Will Be Supplied Alongwith The Paint Should Be Imported One. The Anti Bacterial And Anti Fungus Coating Should Not Peel Off Early And Will Have To Be Warranted By The Vendor To Last Atleast 05 Years. 4 Antistatic Conductive Flooring: Seamless With Perfectly Curved Flush-Covings, Resistance To Mechanical Stresses And Dynamic Loads And Having Conductive Protection Characteristics, 2 Mm Thick, Washable. Make- As Per Civil Makelist / Brands ( As Per Specification } 5 Planair Ceiling System System Constructed Out Of 1.6 Mm Aluminium With Extruded Aluminium Profile Frame And Sealed Gasket.Size 2800 X 2400 Mm Having 08 Numbers Of H-14 Grade Hepa Filters. The Hepa Filters Having Dust Spot Efficiency Of 99.99% 0.03 Micron. Air & Light Diffuser Made Of Mono Filament Precision Woven Polyester For The Plan Air Ceiling To Give A Laminar Flow Of Filtered Air As Per Tender Specifications. Make- Hindalco / Nalco / Jindal - 6 Optional : Planair Ceiling System System Constructed Out Of 1.5 Mm Thick Ss 304 1.0 Mm Thick Sheet Of Size 2800 X 2400 Mm Having 08 Numbers Of H-14 Grade Hepa Filters. The Hepa Filters Having Dust Spot Efficiency Of 99.99% 0.03 Micron. Air & Light Diffuser Made Of Mono Filament Precision Woven Polyester For The Plan Air Ceiling To Give A Laminar Flow Of Filtered Air As Per Tender Specifications.Make : As Per Civil Makelist / Brands ( As Per Specification } 7 Surgeon Control Panel, Touch Screen 21 : The Panel Should Contain Features Like Real Time Clock - Hh:Mm:Ss Format With Day, Time Elapse Day Clock, Peripheral Light Control System, Ot Light On / Off Control System, Medical Gas Status ( High / Low / Normal ) With Audible Alarm For Gases Oxygen, Nitrous Oxide, Vacuum, Medical Air 4 Bar And Surgical Air 7 Bar, Carbon Dioxide. Hand Free Telephone Set With Memory And Should Be Compatible For Digital Telephone System ) . Temperature And Humidity Indicator With Controller, Hepa Filter Status Module, Ot Differentail Pressure Indicator System, Music Control System With Appropriate Number Of Speakers As Per Ot Area. As Per Technical Specification. 8 Two Plate ( Plate Size 14 X 17 ) Led X-Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flicker. ( As Per Technical Specification ) 9 Peripheral Lights Led Lights With Dimmable Electronic Blast, Size 300 Mm X 600 Mm ( As Per Technical Specification ) . 10 Ot Main Door Automatic Sliding, Hermetically Sealing Type Of Size 2100 ( H ) X 1800 Mm ( W ) As Per Tender Specifications. Make-Metaflex / Sonnemed / Grupsa / Sonnemed / Portalp ( As Per Technical Specification ) . 11 Radar Hand Switch ( As Per Specification ) 12 Foot Switch ( As Per Technical Specification ) 13 Storage Unit Of Size 1666 X 865 X 350 ( Sizes In Mm ) ( + / -5 % ) Material- Ss 304 Having Two Shelves And Made Out Of Having 5 Mm Thick Trqansparent Toughned Glass Door In Aluminium Extruded Frame And Mounted Flush With The Theatre Wall. ( As Per Technical Specification ) 14 Cascade Pressure Stabilizer Having Multi 304 Graded Stainless-Steel Blades To Control Room Air Pressure. 15 Writing Board ( As Per Specification ) . 16 Electrical Wiring Conduiting Switch Socket Etc For Each Ot, Conduits For Integration Tv Monitor, Camera Etc. ( As Per Tender Specification ) . 17 Aluminium Ducting Work With Nitrile Rubber Thermal Insulation With Aluminium Foil ( 25Mm For Supply Duct +13Mm For Return Duct ) And Exhaust Return Grill With Colar Damper In Operating Rooms ( As Per Specification ) Note -Inside Ot Area Only 18 Medical Gas Line Inside The Ot For O2, N2o, Air-4 / 7, Vac, Co2 & Agss ( As Per Specification ) With Suitable Connector / Adaptor 19 Viewing Window - Size 2000 Mm ( H ) X 1000 Mm ( W ) . The View Window Should Be Double Insulated Fixed Glazing Not Less Than 5 Mm Thick Toughened Safe Glass With Motorized Venetian Blinds Size As Per Drawing. ( As Per Technical Specification ) 20 Wall Mounted Led / Ips Flat Screen Display 54 - As Per Technical Specification. 21 Work Station / Cpu Cabinet Should Have Shelf Keyboard Cpu Cabin ( As Per Technical Specification ) . 22 Isolation Panel ( For Ot ) With Ground Fault Monitoring System ( Isolation Panel For Ot As Described In Schedule 3 ) 23 Isolation Panel ( For Procedure Room ) . ( Isolation Panel For Procedure Room As Described In Scheduled 3 ) 24 Hepa Filters 25 Peripheral Light 26 Door Handle 27 Blast 28 Door Gasket

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:C2-Modular OT
Sl. No. Item Description
1C2-Modular OT
2Supply and Installation of SS 304 Puff Panel , Thickness: 50 MM. Front panel SS -304 wall thickness: 1.0 MM.Back panel material SS 304 ,wall thickness : 0.8 MM . Make- Jindal/ Tata Steel/ SAIL (As Per Technical Specification). Antimicrobial Coating: Filling of all Joints and cavities with metallic Epoxy Filler and Sanded Flush to provide a jointless finish.
3OPTIONAL Quote for : Anti bacterial Epoxy and anti fungus sterile coating to be applied on the SS-304 finished walls and ceilling with at least 3-4 coat to achieve dry film thickness of minimum 200-300 Micron. The Primer will be supplied alongwith the paint should be imported one. the Anti bacterial and anti fungus coating should not peel off early and will have to be warranted by the vendor to last atleast 05 years.
4Antistatic Conductive Flooring: Seamless with perfectly curved flush-covings, resistance to mechanical stresses and dynamic loads and having conductive protection characteristics, 2 mm thick, washable. Make- As per Civil Makelist/Brands(As Per Specification}
5Planair Ceiling System system constructed out of 1.6 MM Aluminium with extruded aluminium profile frame and sealed gasket.Size 2800 x 2400 MM having 08 numbers of H-14 grade HEPA filters. The HEPA filters having dust spot efficiency of 99.99% 0.03 micron. Air & Light diffuser made of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air as per Tender specifications. Make- Hindalco/ NALCO/JINDAL -
6OPTIONAL : Planair Ceiling System system constructed out of 1.5 MM thick SS 304 1.0 MM thick sheet of size 2800 x 2400 MM having 08 numbers of H-14 grade HEPA filters. The HEPA filters having dust spot efficiency of 99.99% 0.03 micron. Air & Light diffuser made of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air as per Tender specifications.Make : As per Civil Makelist/Brands(As Per Specification}
7Surgeon Control Panel, Touch Screen 21 : The panel should contain features like Real time clock - HH:MM:SS format with day, Time Elapse day clock, peripheral light control system, OT light ON/OFF control system,Medical gas status (High/low/normal) with audible alarm for gases Oxygen,Nitrous Oxide, Vacuum,Medical Air 4 Bar and Surgical Air 7 Bar, Carbon Dioxide. Hand free telephone set with memory and should be compatible for Digital telephone system). Temperature and humidity Indicator with controller, HEPA filter status module, OT differentail pressure indicator system, Music control system with appropriate number of speakers as per OT area. As per Technical specification.
8Two Plate (Plate Size 14 " X 17 " ) LED X-Ray Viewing Screen designed to provide a high level of control luminance without flicker. (As Per Technical Specification)
9Peripheral lights LED lights with dimmable electronic Blast, size 300 MM x 600 MM (As Per Technical Specification).
10OT Main Door Automatic Sliding, hermetically sealing type of size 2100 (H) X 1800 mm (W) as per Tender specifications. Make-Metaflex/ Sonnemed / Grupsa / SonneMed / Portalp (As Per Technical Specification).
11Radar hand switch (As Per Specification)
12Foot Switch (As Per Technical Specification)
13Storage Unit of size 1666 X 865 X 350 (Sizes in MM) (+/-5 %) Material- SS 304 having two shelves and made out of having 5 MM thick trqansparent toughned glass door in Aluminium Extruded frame and mounted flush with the theatre wall. (As Per Technical Specification )
14Cascade Pressure Stabilizer having multi 304 graded stainless-steel blades to control room air pressure.
15Writing Board (As Per Specification).
16Electrical wiring conduiting switch socket etc for each OT, conduits for integration TV monitor, Camera etc. (As Per Tender Specification).
17Aluminium Ducting work with Nitrile Rubber Thermal Insulation with aluminium foil ( 25mm for supply duct +13mm for return duct) and Exhaust Return Grill with colar damper in Operating Rooms (As Per Specification) note -inside OT area only
18Medical Gas Line Inside the OT for O2, N2O, Air-4/7, Vac, CO2 & AGSS (As Per Specification) with suitable connector/adaptor
19Viewing Window - Size 2000 MM (H) X 1000 MM (W). The view window should be double insulated fixed glazing not less than 5 MM thick toughened safe glass with Motorized venetian blinds size as per drawing. (As Per Technical Specification)
20WALL MOUNTED LED/IPS FLAT SCREEN DISPLAY 54 "- As per Technical specification.
21WORK STATION/ CPU Cabinet should have shelf keyboard CPU cabin (As Per Technical Specification).
22Isolation Panel (For OT) with ground fault monitoring system (Isolation Panel For OT as described in schedule 3)
23Isolation Panel (For PROCEDURE ROOM) . (Isolation Panel For PROCEDURE ROOM as described in scheduled 3)
24HEPA Filters
25Peripheral Light
26Door Handle
27Blast
28Door Gasket