| Sl. No. | Item Description |
| 1 | CIVIL WORK -Removinggrass,gazergrassand disposingoffoutofbuildingpremisesincludingmaking clean the ground by shovel and phavaras etc. complete. |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingthe excavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingas directed,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 3 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto1.50m)ByMechanical Means |
| 4 | Excavationforfoundationinhardmurumandbouldersincludingremovingtheexcavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed,dewatering,preparingthebedforthefoundationandnecessarybackfilling, ramming,wateringincludingshoringandstruttingetc.complete.(Liftupto1.5m.)By Mechanical Means |
| 5 | ExcavationforfoundationinHardmurum andbouldersincludingremoving theexcavated material upto adistanceof50metres,beyondthebuildingareaandstackingandspreadingasdirected, dewatering, preparingthebed forthefoundation and necessarybackfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means |
| 6 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering,preparingthebedforth |
| 7 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling withavailable earth/murum, ramming ,watering including shoring andstrutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means |
| 8 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling withavailable earth/murum, ramming ,watering including shoring andstrutting etc. complete. (Lift from 3.0 m To 4.5 m.) By Mechanical Means |
| 9 | Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed bychisellingwherenecessaryandremovingtheexcavatedmaterialandstackingitin measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramming etc. complete. (Lift from 3 m To 4.5m) By Mechanical Means |
| 10 | Excavationfor foundationin Hardrock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyondthebuildingareastackingasdirected,dewateringandbackfillingwithavailable earth/ murum watering, ramming etc. complete. (Lift from 1.5 m to 3.0 m ). By Mechanical Means |
| 11 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating thebottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifos persquaremete |
| 12 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment bytreatingthe backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per |
| 13 | ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)bytreatingthetopsurface of plinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosper squaremetre of surface area covering ten years guarantee on bond paper. |
| 14 | Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.Layers including watering and compacting etc. complete. |
| 15 | Fillinginplinthandfloorswithcontractors material/broughtfromoutsideandapprovedbyEngineer incharge inlayersof15cm to20cmincludingwateringandcompactionetc.complete. |
| 16 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete. |
| 17 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steelcentering,formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredand curingcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Typemixer/concreteBatchmixplant(Panmixer)etc.complete. Withfineaggregate(CrushedsandVSIGrade) |
| 18 | Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneissmetalforstepsincludingsteelcentering,formwork,laying/pumping,compacting, rougheningthemifspecial finish is tobeprovided,finishinguneven andhoneycombedsurface and curing etc. complete. The Cement Mortar 1:3plaster is consideredfor rendering uneven andhoneycombed surface,only.Newlylaidconcreteshallbecoveredby gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fullyautomaticmicroprocessorbasedPLCwithSCADA enabled reversible Drum Type mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate(Crushed sand VSI Grade) |
| 19 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc |
| 20 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings ofR.C.C.columnsandsteelstanchionsetc.columnsasperdetaileddesignsanddrawingorasdirected includingSteel centering formwork, coverblocks laying/pumping,compaction finishing the formed surfaceswithcementmortar1:3ofsufficientminimum thickness to give a smooth and even surface or rougheningifspecialfinishistobeprovidedandcuringetc.complete.(Excludingreinforcementand structural steel). with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concrete Batchmix plant (Pan mixer) etc. complete. Withfine aggregate (CrushedsandVSI Grade) |
| 21 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or asdirected including steel centering, for |
| 22 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-35oftrap/granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering,formwork,coverblocks,laying/pumGround floor |
| 23 | First floor |
| 24 | Second floor |
| 25 | Terrace Floor |
| 26 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-40oftrap/granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering,formwork,coverblocks,laying/pumping,compactionfinishing the formedsurfaceswithcement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground floor |
| 27 | First floor |
| 28 | Second floor |
| 29 | Third floor |
| 30 | Fourth floor |
| 31 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering,formwork,coverblocks,laying/pumping,compactionfinishingtheformedsurfaceswithcement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground floor |
| 32 | First Floor |
| 33 | Second Floor |
| 34 | Third floor |
| 35 | Fifth floor |
| 36 | Sixth floor |
| 37 | Seventh floor |
| 38 | Eighth floor |
| 39 | Nineth floor |
| 40 | Tenth floor |
| 41 | Eleventh floor |
| 42 | Twelveth floor |
| 43 | Terrace floor |
| 44 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-40oftrap/granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade)Ground floor |
| 45 | First floor |
| 46 | Second floor |
| 47 | Third floor |
| 48 | Fourth floor |
| 49 | Providing and laying Cast in situ/Ready Mixcement concrete M-35 of trap / granite /quartzite/ gneiss metal for R.C.C.beamsandlintelsasperdetaileddesignsanddrawingsorasdirectedincluding steelcentering, formwork, cover blGround floor |
| 50 | First floor |
| 51 | Second floor |
| 52 | Terrace Floor |
| 53 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedandcuringetc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground floor |
| 54 | First floor |
| 55 | Second floor |
| 56 | Third floor |
| 57 | Fifth floor |
| 58 | Sixth floor |
| 59 | Seventh floor |
| 60 | Eighth floor |
| 61 | Nineth floor |
| 62 | Tenth floor |
| 63 | Eleventh floor |
| 64 | Twelveth floor |
| 65 | Terrace floor |
| 66 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is tobeprovidedandcuringetc.complete.(Excludingreinforcement and structural steel).with fully automaticmicroprocessorbased PLC withSCADA enabled reversibleDrumTypemixer/ concrete Batchmixplant(Panmixer)etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 67 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction fin |
| 68 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-40oftrap/granite/ quartzite/ gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground floor |
| 69 | First floor |
| 70 | Second floor |
| 71 | Third floor |
| 72 | Fourth floor |
| 73 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-35oftrap/granite/ quartzite/ gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blockGround floor |
| 74 | First floor |
| 75 | Second floor |
| 76 | Terrace Floor |
| 77 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-30oftrap/granite/ quartzite/ gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground floor |
| 78 | First floor |
| 79 | Second floor |
| 80 | Third floor |
| 81 | Fifth floor |
| 82 | Sixth floor |
| 83 | Seventh floor |
| 84 | Eighth floor |
| 85 | Nineth floor |
| 86 | Tenth floor |
| 87 | Eleventh floor |
| 88 | Twelveth floor |
| 89 | Terrace floor |
| 90 | Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/quartzite/ gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete. (Excludingreinforcementand structuralsteel).withfullyautomatic microprocessor based PLC with SCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)etc.complete. Withfineaggregate(Crushed sand VSI Grade)Ground floor |
| 91 | First floor |
| 92 | Second floor |
| 93 | Third floor |
| 94 | Fourth floor |
| 95 | Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/quartzite/ gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete. (Excludingreinforcementand structuralsteel).withfullyautomatic microprocessor based PLC with SCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)etc.complete. Withfineaggregate(Crushed sand VSI Grade)Ground floor |
| 96 | First floor |
| 97 | Second floor |
| 98 | Third floor |
| 99 | Fifth floor |
| 100 | Sixth floor |
| 101 | Seventh floor |
| 102 | Eighth floor |
| 103 | Nineth floor |
| 104 | Tenth floor |
| 105 | Eleventh floor |
| 106 | Twelveth floor |
| 107 | Terrace floor |
| 108 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-40oftrap/quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawingsoras directedincludingsteelcentering,plywood/steelformwork,steelprops, laying/pumping,compaction, finishinguneven and honeycombed surfacewith C.M. 1:3 ofsufficientminimumthicknesstogivea smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrum Type mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade)Ground floor |
| 109 | First floor |
| 110 | Second floor |
| 111 | Third floor |
| 112 | Fourth floor |
| 113 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-30oftrap/quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawingsoras directedincludingsteelcentering,plywood/steelformwork,steelprops, laying/pumping,compaction, finishinguneven and honeycombed surfacewith C.M. 1:3 ofsufficientminimumthicknesstogivea smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrum Type mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade)Ground floor |
| 114 | First floor |
| 115 | Second floor |
| 116 | Third Floor |
| 117 | Fifth floor |
| 118 | Sixth floor |
| 119 | Seventh floor |
| 120 | Eighth floor |
| 121 | Nineth floor |
| 122 | Tenth floor |
| 123 | Eleventh floor |
| 124 | Twelveth floor |
| 125 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade)Ground floor |
| 126 | First floor |
| 127 | Second floor |
| 128 | Third floor |
| 129 | Fourth floor |
| 130 | Fifth floor |
| 131 | Sixth floor |
| 132 | Seventh floor |
| 133 | Eighth floor |
| 134 | Nineth floor |
| 135 | Tenth floor |
| 136 | Eleventh floor |
| 137 | Twelveth floor |
| 138 | Terrace floor |
| 139 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/quartzite/ gneissmetalforR.C.C.coping to plinthorparapetandsill ofdoors andwindows mouldedas perdetailed drawingsorchamferedasapprovedbytheEngineerincludingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing androughening them if special finish is to be provided and curing complete. (Excludingreinforcement and structural steel).with fully automatic microprocessorbasedPLCwith SCADAenabledreversibleDrumTypemixer/concreteBatchmix plant(Panmixer)etc. complete. With fine aggregate (Crushed sand VSI Grade)Ground floor |
| 140 | First floor |
| 141 | Second Floor |
| 142 | Third floor |
| 143 | Fourth floor |
| 144 | Fifth floor |
| 145 | Sixth floor |
| 146 | Seventh floor |
| 147 | Eighth floor |
| 148 | Nineth floor |
| 149 | Tenth floor |
| 150 | Eleventh floor |
| 151 | Twelveth floor |
| 152 | Terrace floor |
| 153 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C.chajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade)Ground floor |
| 154 | First floor |
| 155 | Second floor |
| 156 | Third floor |
| 157 | Fourth floor |
| 158 | Fifth floor |
| 159 | Sixth floor |
| 160 | Seventh floor |
| 161 | Eighth floor |
| 162 | Nineth floor |
| 163 | Tenth floor |
| 164 | Eleventh floor |
| 165 | Twelveth floor |
| 166 | Terrace floor |
| 167 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings andschedules.including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Ground floor |
| 168 | First floor |
| 169 | Second floor |
| 170 | Third floor |
| 171 | Fourth floor |
| 172 | Fifth floor |
| 173 | Sixth floor |
| 174 | Seventh floor |
| 175 | Eighth floor |
| 176 | Nineth floor |
| 177 | Tenth floor |
| 178 | Eleventh floor |
| 179 | Twelveth floor |
| 180 | Terrace floor |
| 181 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.Ground floor |
| 182 | First floor |
| 183 | Second floor |
| 184 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure includingstrikingjoints,rakingoutjoints,wateringandscaffoldingetc. Complete |
| 185 | ProvidingAutoclavedAeratedConcreteBlockmasonaryof conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Ground floor |
| 186 | First floor |
| 187 | Second floor |
| 188 | Third floor |
| 189 | Fourth floor |
| 190 | Fifth floor |
| 191 | Sixth floor |
| 192 | Seventh floor |
| 193 | Eighth floor |
| 194 | Nineth floor |
| 195 | Tenth floor |
| 196 | Eleventh floor |
| 197 | Twelveth floor |
| 198 | Terrace floor |
| 199 | Providing Autoclaved Aerated Concrete Block masonary of conformingto IS:2185(Part3)-1984in extrafinejointingmortaroffixoblockofUltraTechor equivalent in Half brick thick wall including strikingjoints,rakingoutjointsand scaffolding etc. Complete. (The test shall be carried out conforming toIS:6441 (Part I) - 1972)Ground floor |
| 200 | First floor |
| 201 | Second floor |
| 202 | Third floor |
| 203 | Fourth floor |
| 204 | Fifth floor |
| 205 | Sixth floor |
| 206 | Seventh floor |
| 207 | Eighth floor |
| 208 | Nineth floor |
| 209 | Tenth floor |
| 210 | Eleventh floor |
| 211 | Twelveth floor |
| 212 | Providingsandfacedplasterexternallyincementmortarusingapprovedscreenedsand,inallpositions including base coat of 15 mm thick in cement mortar 1:4 using waterproofingcompoundat 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoat roughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurface bytakingoutgrainsandcuringforfourteendays scaffolding etc.complete.Ground floor |
| 213 | Providing and applying gypsum plaster ( with Gypsum material) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.Ground floor |
| 214 | First floor |
| 215 | Second floor |
| 216 | Third floor |
| 217 | Fourth floor |
| 218 | Fifth floor |
| 219 | Sixth floor |
| 220 | Seventh floor |
| 221 | Eighth floor |
| 222 | Nineth floor |
| 223 | Tenth floor |
| 224 | Eleventh floor |
| 225 | Twelveth floor |
| 226 | Terrace floor |
| 227 | ProvidingwaterproofplasterinW.C.andbath 12mmthickfordadoincementmortar1:3withneat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete.(Excluding Tiles) (As directed by Engineer in Charge)Ground floor |
| 228 | First floor |
| 229 | Second floor |
| 230 | Third floor |
| 231 | Fourth floor |
| 232 | Fifth floor |
| 233 | Sixth floor |
| 234 | Seventh floor |
| 235 | Eighth floor |
| 236 | Nineth floor |
| 237 | Tenth floor |
| 238 | Eleventh floor |
| 239 | Twelveth floor |
| 240 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:3without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.Ground floor |
| 241 | First floor |
| 242 | Second floor |
| 243 | Third floor |
| 244 | Fourth floor |
| 245 | Fifth floor |
| 246 | Sixth floor |
| 247 | Seventh floor |
| 248 | Eighth floor |
| 249 | Nineth floor |
| 250 | Tenth floor |
| 251 | Eleventh floor |
| 252 | Twelveth floor |
| 253 | Terrace floor |
| 254 | Providing internal / external 20 mm thick Ready Mix plaster confirming to IS:4031(Part-4) 1988 and IS 383- 1970 ina single coat using Cement mortar of proportion1:4containing special type of polymeradditives about 0.4%, to all type of surfaces in all positions including scaffolding and curing complete.Ground floor |
| 255 | First floor |
| 256 | Second floor |
| 257 | Third floor |
| 258 | Fourth floor |
| 259 | Fifth floor |
| 260 | Sixth floor |
| 261 | Seventh floor |
| 262 | Eighth floor |
| 263 | Nineth floor |
| 264 | Tenth floor |
| 265 | Eleventh floor |
| 266 | Twelveth floor |
| 267 | Terrace floor |
| 268 | Providing and applying Texture Plaster Of STONETEX - TRAVERTINE SERIES -ST-2002special luxurious stone finish coating (3 product type – 6 coat system) for exteriors and interiors. Texture midcoat incorporating natural stone granules like natural Sandstone, Granite, Limestone, Ceramic chips, natural sand etc. including grooves to be provide as per design and drawings. Apply two coats of under coat primer by roller or brush then apply masking tape to create grooves as per design and drawings. First coat of texture midcoat finish by spray gun, evenly over the entire surface. Apply second coat of texture midcoat finish by spray sprinkle method, evenly on the whole sea of the previously dried first coat. Apply two coats of top protective coat evenly on the surface including grooves with roller or brush. It should be water based and ecofriendly product including preparing the surface, scaffolding etc. complete as directed by Engineer in-charge.Ground floor |
| 269 | First floor |
| 270 | Second floor |
| 271 | Third floor |
| 272 | Fourth floor |
| 273 | Fifth floor |
| 274 | Sixth floor |
| 275 | Seventh floor |
| 276 | Eighth floor |
| 277 | Nineth floor |
| 278 | Tenth floor |
| 279 | Eleventh floor |
| 280 | Twelveth floor |
| 281 | Terrace floor |
| 282 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.Cmembers andbrickwork,ofapprovedqualityincludingfixing meshinpositionby necessary drilling in concrete/B.B.masonry and or tying by binding wire etc. complete.Ground floor |
| 283 | First floor |
| 284 | Second floor |
| 285 | Third floor |
| 286 | Fourth floor |
| 287 | Fifth floor |
| 288 | Sixth floor |
| 289 | Seventh floor |
| 290 | Eighth floor |
| 291 | Nineth floor |
| 292 | Tenth floor |
| 293 | Eleventh floor |
| 294 | Twelveth floor |
| 295 | Terrace floor |
| 296 | ProvidingandapplyingRoyaleLuxuryEmulsionofapprovedmakeoninternalwallsurfaceas detailed belowScrappingforsurfacewithemerypaperandwipecleanforarea. wall primer withbrushby adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dryfor 6 to8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of4to6hours ofactivity.Scrappingwithemerypaper andwipecleanApplying paints Royale Luxury emulsion 1st coatwithbrushwatercontentwater40to45%or65to70%byroleApplyingpaintsRoyaleluxury emulsion 2nd coat with brush with water content 40 to 45%or 65 to 70 % by roller. (With prior approval of S.E.)Ground floor |
| 297 | First floor |
| 298 | Second floor |
| 299 | Third floor |
| 300 | Fourth floor |
| 301 | Fifth floor |
| 302 | Sixth floor |
| 303 | Seventh floor |
| 304 | Eighth floor |
| 305 | Nineth floor |
| 306 | Tenth floor |
| 307 | Eleventh floor |
| 308 | Twelveth floor |
| 309 | Terrace floor |
| 310 | Providingandapplying antipeelpaintofapproved make& approvedbrandexterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint).Ground floor |
| 311 | First floor |
| 312 | Second floor |
| 313 | Third floor |
| 314 | Fourth floor |
| 315 | Fifth floor |
| 316 | Sixth floor |
| 317 | Seventh floor |
| 318 | Eighth floor |
| 319 | Nineth floor |
| 320 | Tenth floor |
| 321 | Eleventh floor |
| 322 | Twelveth floor |
| 323 | Terrace floor |
| 324 | Providing andapplying twocoatsofHighAlbedopainthavingminimum SolarReflective Index (SRI) 108(withsolarreflectance&thermalemittancetestedasperASTM)C1549andASTM C 1371 respectively,VOClessthan10cc/gm.Thecoatingthicknessandthe methodology of application shall strctly as per manufacturer\"s specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performanceofSRIandalsothedurabitityofcoating,allcompleteasper directionof Engineer - in- incharge.Second Floor |
| 325 | Third Floor |
| 326 | Terrace floor |
| 327 | Bamboowood 10mm thick Wall Cladding including Threshold & T-mold - Providing & fixing in position Phenol bonded Bamboowood wall cladding at all height with planks of sizes 10mm thick, 1900mm length (minimum) and 135mm wide approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials & Technology Promotion Council (BMTPC). with necessary profiled edges fixed with BR nails to frame work made of second class teak wood of size 50 x 50mm in centre and ends of each tile. The bamboowood cladding shall be laid over teak wood frame and hold in place by 50mm thick teak wood placed in centre of two teak wood and backlayment and covered with 1.00mm thick expanded poly ethylene foam of density 25Kilogram/cum in two layers first layer on wall surface before fixing wooden frame and second layer on frame under cladding. The Bamboowood planks shall have minimum density of 1000 Kilogram/cum & minimum Hardness 1000 Kilogramf. with Eco friendly UV coating, all complete as per direction of Engineer in-charge.Ground floor |
| 328 | First floor |
| 329 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laidinrequiredslopetodrainthewaterforanyspanaftercleaningthebasesurface.Applyingacoatof cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layerfor3days,applyingcementslurryoverthislayerjointsofbrickbatswithC.M.1:3admixedwith approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed withapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldat thejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofness onCourtfeestamppaperofRs.500/- including ponding test etc. complete.Ground Floor |
| 330 | Third Floor |
| 331 | Terrace floor |
| 332 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providingand laying12mmbeddingincementmortor1:3onverginconcreteslabwith waterproofing compound @ 1Kilogram/perbagofcementlayingbrickbatcobaof requiredthicknessincm1:5 with waterproofing compound1Kilogram/bag ofcement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48hoursbypondtestandcoveringtenyears\"guaranteeonrequisitestamppaperincludingcuringetc.complete.Ground floor |
| 333 | First floor |
| 334 | Second floor |
| 335 | Third floor |
| 336 | Fourth floor |
| 337 | Fifth floor |
| 338 | Sixth floor |
| 339 | Seventh floor |
| 340 | Eighth floor |
| 341 | Nineth floor |
| 342 | Tenth floor |
| 343 | Eleventh floor |
| 344 | Twelveth floor |
| 345 | Providingandapplyingwaterproofingtreatmentusingacrylicpolymermodifiedcement basedwater proofing coating with fibre glass mesh mixing at the rate of powder to liquid(2:1) by weight covering9to10SquareMetre/Kilogramwithtwocoatusingapproved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.Ground Floor |
| 346 | First floor |
| 347 | Second floor |
| 348 | Third floor |
| 349 | Fourth floor |
| 350 | Fifth floor |
| 351 | Sixth floor |
| 352 | Seventh floor |
| 353 | Eighth floor |
| 354 | Nineth floor |
| 355 | Tenth floor |
| 356 | Eleventh floor |
| 357 | Twelveth floor |
| 358 | Terrace floor |
| 359 | Providingandfixing20to25mmthickroughshahabadboxtypewaterproofingforbasementor undergroundflooronabaseofCementconcrete1:3:6,includingsub baseof2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )Ground floor |
| 360 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gapof 25 mm betweenrough shahabadand R.C.C. walls withcement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushingthejointshorizontallywithcementslurrymixed withwaterproofingliquidfor width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom mostwithCementconcrete 1:2:4mixedwithwaterproofing liquid,curing,with 7 yearsguaranteeoncourtfeestampofRs.100/-withponding testetccomplete.(excluding Cement concrete 1:3:6 base concrete)Ground floor |
| 361 | Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (groupDII-A)and7to8mm thickforflooring inrequiredpositionlaidonabedof1:4cementmortar including cement float, fGround floor |
| 362 | First floor |
| 363 | Second floor |
| 364 | Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling wiGround floor |
| 365 | First floor |
| 366 | Second floor |
| 367 | Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mm of8to10mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make,shade and pattern for flooring in required position laid on a bed of 1:4 cement morarincludingneatcementfloat,filling joints, curing and cleaning etc. complete.Ground floor |
| 368 | First floor |
| 369 | Second floor |
| 370 | Third floor |
| 371 | Fourth floor |
| 372 | Fifth floor |
| 373 | Sixth floor |
| 374 | Seventh floor |
| 375 | Eighth floor |
| 376 | Nineth floor |
| 377 | Tenth floor |
| 378 | Eleventh floor |
| 379 | Twelveth floor |
| 380 | Providing and laying vitrified matt finish tileshaving size 590 mm to 605 mm x to 605 mm of8to10mm thicknessandconfirmingIS.15622-2006(GroupBla)ofapprovedmake, shadeandpatternfordado andskirtinginrequiredpositionfixedin1:4cementmortar including neat cement float, filling joints,curing and cleaning etc. complete.Ground floor |
| 381 | First floor |
| 382 | Second floor |
| 383 | Third floor |
| 384 | Fourth floor |
| 385 | Fifth floor |
| 386 | Sixth floor |
| 387 | Seventh floor |
| 388 | Eighth floor |
| 389 | Nineth floor |
| 390 | Tenth floor |
| 391 | Eleventh floor |
| 392 | Twelveth floor |
| 393 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / OceanBrowngranite stone ofapprovedshade andsize 18 mm to 20mm thickon bed1:6cementmortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.Ground floor |
| 394 | First floor |
| 395 | Second floor |
| 396 | Third floor |
| 397 | Fourth floor |
| 398 | Fifth floor |
| 399 | Sixth floor |
| 400 | Seventh floor |
| 401 | Eighth floor |
| 402 | Nineth floor |
| 403 | Tenth floor |
| 404 | Eleventh floor |
| 405 | Twelveth floor |
| 406 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortar includingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete.Ground floor |
| 407 | First floor |
| 408 | Second floor |
| 409 | Third floor |
| 410 | Fourth floor |
| 411 | Fifth floor |
| 412 | Sixth floor |
| 413 | Seventh floor |
| 414 | Eighth floor |
| 415 | Nineth floor |
| 416 | Tenth floor |
| 417 | Eleventh floor |
| 418 | Twelveth floor |
| 419 | Terrace floor |
| 420 | Providingand fixingmachinecutmirror polished 18 mm to 20 mm thicktelephoneblack granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc.complete . Both side polishGround floor |
| 421 | First floor |
| 422 | Second floor |
| 423 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section Ground floor |
| 424 | Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixingofstoneasperdrawing anddesign,includingcleaning,washingandfinishingetc. complete.Ground floor |
| 425 | First floor |
| 426 | Second floor |
| 427 | Third floor |
| 428 | Fourth floor |
| 429 | Fifth floor |
| 430 | Sixth floor |
| 431 | Seventh floor |
| 432 | Eighth floor |
| 433 | Nineth floor |
| 434 | Tenth floor |
| 435 | Eleventh floor |
| 436 | Twelveth floor |
| 437 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / OceanBrown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler Numbering/moulding the sharp edges wherever necessary, curing,etc. complete.Ground floor |
| 438 | First floor |
| 439 | Second floor |
| 440 | Third floor |
| 441 | Fourth floor |
| 442 | Fifth floor |
| 443 | Sixth floor |
| 444 | Seventh floor |
| 445 | Eighth floor |
| 446 | Nineth floor |
| 447 | Tenth floor |
| 448 | Eleventh floor |
| 449 | Twelveth floor |
| 450 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequired widthinplain/diamondpatternonbed of1:6 C.M.including cementfloat, filling joints withneat cement slurry, curing, polishing and cleaningetc. complete.Ground floor |
| 451 | First floor |
| 452 | Second floor |
| 453 | Providing andfixing in required positionskirting or dado of polishedKotahStone slab25 mm to 30mm thickfixed on base on plasterofcementmortar 1:4 including cementfloat, filling joints withcement slurry, curing rubbing, polishing and cleaning complete.Ground floor |
| 454 | First floor |
| 455 | Second floor |
| 456 | Providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600 mm x 450mm sizeasperdetailed drawingincludingverticalboth sidepolished kadappahstone25to30mmthick supportswithkadappah top35to 40mm thickandpolishedgranite 16to 20mm topwithside stripsof granite at front and both sides of platform raised with two verticalgranitesupports15cmheightandtop graniteof75x40cmincludingcutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)Ground floor |
| 457 | First floor |
| 458 | Second floor |
| 459 | Providingandfixing30mmthick SOLIDPANELPVCINTERNALDOORSHUTTER consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for stiles ,top, lock and bottom rails. M.S. frame shall have a coat of steel primersGround floor |
| 460 | First floor |
| 461 | Second floor |
| 462 | Third floor |
| 463 | Fourth floor |
| 464 | Fifth floor |
| 465 | Sixth floor |
| 466 | Seventh floor |
| 467 | Eighth floor |
| 468 | Nineth floor |
| 469 | Tenth floor |
| 470 | Eleventh floor |
| 471 | Twelveth floor |
| 472 | Solid Core Flush door Single leaf Providingandfixingfactorymadesolid coreflushdoorinsingleleaf35mmthick,decorativetypes,of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessarybeads,mouldingandlipping,holdfasts,matfinishstainlesssteelfixturesfastenings,finishing withfrench-polish/waxingcomplete.(withoutdoorframe).(SampletobegotapprovedfromEx.Engineer before use) Commercial Hard Wood shutterGround floor |
| 473 | First floor |
| 474 | Second floor |
| 475 | Third Floor (Terrace floor) |
| 476 | Solid Core Flush door Double leafProviding and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type ofexterior grade,as perdetaileddrawings,conforming to I.S.: 2202– 1966(Revised) including approved face veneersonbothsides,withoutglazing andvenetiansincluding matfinishstainlesssteel fixturesand fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutterGround floor |
| 477 | First floor |
| 478 | Second floor |
| 479 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete.Ground floor |
| 480 | First floor |
| 481 | Second floor |
| 482 | Providing and applying melamine polish of required finish to the wood work by spraymachine includingknottingandpreparingtheevensurfacebyscraping,applyingFrench polish , scaffolding if required etc. complete.Note:The work to be executed on prior approval of Superintending Engineer will be necessary.Ground floor |
| 483 | First floor |
| 484 | Second floor |
| 485 | Providing of120 min Fire rated lead lined doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 with standard heating conditions as specified inIS:3614PartII1992andBS:476part20&221987toachievetherequiredintegrity,insulationand stability (i.e. to restrict the heat radiation, temperature rise on the nonfire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested withNCBN technology(\"NonCombustiblebyNature\").Leadlinedtocheckradiation.CodeNo;2HourInsulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2.a) Door Frame: Providing Frames for Lead Lined Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 140 X 70 mm with45mm thick two layered 3mm LeadLine Sheets with10mm overlapfrom either side & spray quoted with2coatsofIntumescentpaintofminimum200micron,with1rowofBrush-TypeAstroflame® intumescent strip (imported) of size 10mmx4mm concealed in the groove of the Frame for fire and hot and cold smoke sealing, etc. complete as per direction of Engineer in ChargeGround floor |
| 486 | First floor |
| 487 | Second floor |
| 488 | Third floor |
| 489 | Fourth floor |
| 490 | Fifth floor |
| 491 | Sixth floor |
| 492 | Seventh floor |
| 493 | Eighth floor |
| 494 | Nineth floor |
| 495 | Tenth floor |
| 496 | Eleventh floor |
| 497 | Twelveth floor |
| 498 | Terrace floor |
| 499 | b) Shutter: Providing of 57mm thick asbestos free composite, \"TUFWUD\" brand - 3 criteria - fire, heat and smoke check Lead Lined Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm CalciumSilicateboards,Chemical treated internal timberwith Fireretardant chemicalsin pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x30 mm with30mm thick infill of ceramic fibre (density 128 Kilograms/CMT) vermiculite mix, 3mm thick Lead Sheet on one side faced & 3mm Fire retardant High Density Fibreboard, internallylippedwithhardwoodbeading,andpastedinHydraulicPressunder50tonnespressure,spray quotedwith2coatsofIntumescentpaintofminimum300micron,andwith1rowofBrush-Type Astroflame®intumescentstrip(imported)ofsize 10mmx4mm concealedforfire andsmoke sealing inthe grooves in the shutter on all edges except bottom, without any external lipping.Ground floor |
| 500 | First floor |
| 501 | Second floor |
| 502 | Third floor |
| 503 | Fourth floor |
| 504 | Fifth floor |
| 505 | Sixth floor |
| 506 | Seventh floor |
| 507 | Eighth floor |
| 508 | Nineth floor |
| 509 | Tenth floor |
| 510 | Eleventh floor |
| 511 | Twelveth floor |
| 512 | Terrace floor |
| 513 | c) Vision Panel:2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated \"Z\" channel of 16 swg MS sheet to be fixed for reinforcement of the joints.Ground floor |
| 514 | First floor |
| 515 | Second floor |
| 516 | Third floor |
| 517 | Fourth floor |
| 518 | Fifth floor |
| 519 | Sixth floor |
| 520 | Seventh floor |
| 521 | Eighth floor |
| 522 | Nineth floor |
| 523 | Tenth floor |
| 524 | Eleventh floor |
| 525 | Twelveth floor |
| 526 | Terrace floor |
| 527 | Panic Bar: (For 2 Hr fire Rated single Panic bar) Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style ,made of heavy duty cast iron/ steel body & latches with SS ,BHMA certified & conforming to ANSI A 156.3 for grade-1 ( 3 hours fire rated ) and suitable for surface mounting to wooden/hollow metal/ Al framed door,with maximum operating force 8Kilogram for unlocking easily & outwardly during emergency,complete in all respect as per direction & satisfaction of Engineer-in charge including all taxes & incidental charges. (Note: To be installed at \"FIRE EXIT\"only under location specific instruction of Eingineer-in -Charge.)Ground floor |
| 528 | First floor |
| 529 | Second floor |
| 530 | Third floor |
| 531 | Fourth floor |
| 532 | Fifth floor |
| 533 | Sixth floor |
| 534 | Seventh floor |
| 535 | Eighth floor |
| 536 | Nineth floor |
| 537 | Tenth floor |
| 538 | Eleventh floor |
| 539 | Twelveth floor |
| 540 | Terrace floor |
| 541 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, ExteriorCompound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement,Ground floor |
| 542 | First floor |
| 543 | Second floor |
| 544 | Providingandfixinginpositiontotheexactprofileandprestressingthehightensilestrandstospecified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete.SECOND FLOOR |
| 545 | Providing andfixing inposition powder coated aluminium louvered windows / ventilator of varioussizes withpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38 mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete.Ground floor |
| 546 | First floor |
| 547 | Second floor |
| 548 | Third floor |
| 549 | Fourth floor |
| 550 | Fifth floor |
| 551 | Sixth floor |
| 552 | Seventh floor |
| 553 | Eighth floor |
| 554 | Nineth floor |
| 555 | Tenth floor |
| 556 | Eleventh floor |
| 557 | Twelveth floor |
| 558 | Kitchen TrolleyProvidingandFixingstainlesssteelkitchentrolleyofoverall26\"heightand22\"depth,supportedon aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 \" x 20 \" x 22 \" on both sides of trolley of 12 \" or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by whitemica ,100 mms.s. decorativehandle.(Thewidth and heightof individual compartments shall be kept as directed by Engineer-in-charge)First floor |
| 559 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid ongrid systems with 15mm wide T - sectionflangescolorwhitehavingrotarystitchingontheMainRunner,1200 mmand 600mmCross Tees.Providing andFixing of GI Lay in Plainmetal ceilingconsistingof600x600mmLayintilesofpre coated galvanized steel in 0.5 mm thicknessinGlobalwhite colortile to be laid ongrid systemswith 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Ground floor |
| 560 | First floor |
| 561 | Second floor |
| 562 | Third floor |
| 563 | Fourth floor |
| 564 | Fifth floor |
| 565 | Sixth floor |
| 566 | Seventh floor |
| 567 | Eighth floor |
| 568 | Nineth floor |
| 569 | Tenth floor |
| 570 | Eleventh floor |
| 571 | Twelveth floor |
| 572 | Providing and fixing in position Gypsum board false ceilingwith 12.5 mm thick Gypsum boards, screwed/fixedtotheunderstructureofsuspendedG.I.Gridconstructedand suspended from the main ceilingconsistingofceilingsectionsofsize25x50mmmaximumcenter to center distance of 600 milimetre perimeter channel and intermediate channels atmaximum center to center distance 1200 milimetregalvanizedgridshouldbefixedto reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediatechannels. Additionalintermediatechannelsshouldbefixedtostraphangersforadditional support to prevent strapping at every 1200 milimetre item to be completed inall respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Ground floor |
| 573 | First floor |
| 574 | Second floor |
| 575 | Third floor |
| 576 | Fifth floor |
| 577 | Seventh floor |
| 578 | Nineth floor |
| 579 | Eleventh floor |
| 580 | Providing and fixing Modular false ceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiberboardtobefixedonframeworkofalluminiumsectionsforsuspendedfalse ceiling consisting of alluminiumT2?x1½?(50mmx40mm)weighing0.39 Kilogram/m at 60 cms center center and fixed with ½? x ½? (15 x 15 mm) flanges weighing0.19 Kilogram/m suspended on 6 mm dia mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with alluinium T of 2? x 1 ½? (50 mm x 40 mm) weighing 0.39 Kilogram/m etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.Ground floor |
| 581 | First floor |
| 582 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asper detaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixingin positionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding onecoatofanticorrosivepaintand overit twocoatsofoilpaintingofapprovedqualityandshadeetc.complete.Ground floor |
| 583 | Providing structural steel work of rectangular hollow steel section for steel trusses, othersimilar trusseditemslikepurlinandmemberswithallbracing,gussetplatesetc.asper detailed designs and drawingsor Ground floor |
| 584 | Providingstructuralsteelworkinhollowsectionofvariousthicknessandsizesinsquare, rectangular and round shape from 25mm to 450mmsection as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailFirst floor |
| 585 | Second floor |
| 586 | Providingandfixing900mm highS.S.304Grade Stainlesssteelrailingwith40mm diameterand 1.5mm thickattop,40mm diameterand 1.5mm thickverticalsupportsspaced at 1.5m center tocenter and 8mm thick toughened glass including fabricating ,fixtures, errecting ,necessarywelding,grinding,finishing, buffing to stainless steel pipe etc. completeFirst floor |
| 587 | Second floor |
| 588 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metreasper drawingincludingfixturesnecessaryweldingandpaintingwithonecoatof anticorrosive paint and two coats of oil painting complete.Ground floor |
| 589 | First floor |
| 590 | Second floor |
| 591 | Third floor |
| 592 | Fourth floor |
| 593 | Fifth floor |
| 594 | Sixth floor |
| 595 | Seventh floor |
| 596 | Eighth floor |
| 597 | Nineth floor |
| 598 | Tenth floor |
| 599 | Eleventh floor |
| 600 | Twelveth floor |
| 601 | ProvidingandlayinginsitucementconcreteM30withtremixtreatmentfor200mm thicknessfor flooringwithgroovecuttingof4mmwideand20mmdeepwithnecessary refilling with bitumenetc. complete.Ground floor |
| 602 | Providing & Fixing in position, Carpetmore than 800+ gsm, made with100% stain proof fibres of approved make along with 5mm underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspectsincluding all materials labour,finishiGround floor |
| 603 | First floor |
| 604 | Second floor |
| 605 | Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours firGround floor |
| 606 | SupplyandInstallationoftranslucentroofwithDPIFluxstandingseammulticellpolycarbonatepanel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a completesystem.Co-extrudedUVprotectedpolycarbonatepanelsystem ofmin12mm thickof900mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfyDartdropimpacttestasperIS14443-97shallshownosignofbreakageonPolycarbonatesheets whichhavebeenexposedtoUVforamin.of500HoursasperASTMG155.Panelsshallnothave Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MSstructuralsteel/MSpurlin(paidseparately)conformingtothedetailtechnicalspecificationsasper approvedarchitecturaldrawings.Trainedandfactoryauthorizedlabourwithsupervisiontocompletethe entire panel installation as per drawing & directionof the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs.Second Floor |
| 607 | Third Floor |
| 608 | Terrace floor |
| 609 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers andstepsof18 mmdia. mild steel bar for water tank including fixing it in (1:2:4) M-15cement concrete block 60cmx30cmx30cmandpaintingtheladdercomplete.(Anti Corossive Paint)Second Floor |
| 610 | Third Floor |
| 611 | Terrace floor |
| 612 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gusset platesetc.asperdetaileddesignsanddrawingsorasdirectedincluding cutting,fabricating,hoisting, erecting fixing in position, Making riveted/ bolted/ weldedconnection and onecoatofanticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete.Ground floor |
| 613 | Second floor |
| 614 | Third Floor |
| 615 | Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing withall fixturesandfittingsintwoleaveswithstrong holdfastembeddedinc.c. block at top and bottom with locking arrangement including cut |
| 616 | METALFALSECEILINGWITHOUTSUSPENSIONSUPPORTFROMTRUECEILING:Providing&fixinghorizontallevel suspended metal ceilings comprising of Metalworks F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions withRectangularpanelsmadeof0.7mmthickGalvanisedSteel(GI)of120gsm,postcoatedtoGlobal Whitecolour,suitablefor Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300mm, length ranging from 1500mm to 2660mm. General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7mm as per in IS:513 (1994). Dimensions: The panel Length varies between 1500mm to 2660mm, panel Width shallbe300mm.Thedimensionaltolerancesforlengthshallbe±1.0mupto1000mmL;±1.5mmbetween1001to2000mmL;±2.0mm between 2001 to 3000mm L. The dimensional tolerances for width shall be ±0.5m up to 300mm W. Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3mm(W) x 8mm(H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturnsof minimum30mm(H)and shall be bent appropriately bent as perthe manufacturer‘sspecifications forproviding hook-on ends. The long side shall have inside horizontal bends of 5-15mm for rigidity and vertical upturns of 40mm (for length ranging from1251-2660mm).Surface Finish: Plain: Thepanels shall be inplain unperforatedfinish (withoutany acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017, 250 hours of condensation test (as per DIN 50017 or DIN EN ISO 6270-1 Norms), UV resistance of 500 hours and 50% gloss retention (as per ASTM G 154 UVB-313 Norms). The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E (?e) <1 measured using Excite/BYK Gardner instrument and gloss level of 25±5% at 60° as per ASTM D523.The colour / shade to be Global White (Polyester for Interior) as approved by the Architect or Engineer-in-charge. Surface Protection: The visible panel surface shall be protected using a guard film made of LDPE of 50µthickness,having appropriatesurface adhesion(or tackiness)corresponding to surface glosslevel. Light reflectance: Thepanel shall have a Light Reflectance of = 63% in accordance to ASTM 1477-98. Flatness and Sag limit: Panels shall be flattened by precision leveller to minimize sag to less than Length/400mm. The difference between the two diagonal dimensions of the panel to be less than 1mm. The sag to be measured at the center in accordance with TAIM standards. Access and Plenumspace: The panels to be Fully Accessible, with system height of 98mm, and would require a plenum height of a minimum450mm clear space frombare ceiling / rigid structure for installation. Packaging: The Panels shall be packed in wooden crates of appropriate dimensions based on panel sizes. The wooden planks for rates shall have thickness of approx.15mm, width of around 4? and gap between two planks around 3?. Crates to have layer separators of 1? x 2? dimensions to prohibit load transfer on bottom panels, and the crates lifting to be 2way or 4way. The bottom of crates shall be completely closed, and the panels kept inside shall have cushioning of corrugated sheets or other appropriate material. Installation Specifications: Primary and secondary runners Installation: U-Profiles, spaced at 1200mm, to be suspended from ceiling using clamping brackets and threaded rods OR hanger wires. Hanger wires must be wrapped tightly with 3 full wraps. The J-Ground floor |
| 617 | First floor |
| 618 | Second floor |
| 619 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete.Ground floor |
| 620 | First floor |
| 621 | Second floor |
| 622 | Third floor |
| 623 | Fourth floor |
| 624 | Fifth floor |
| 625 | Sixth floor |
| 626 | Seventh floor |
| 627 | Eighth floor |
| 628 | Nineth floor |
| 629 | Tenth floor |
| 630 | Eleventh floor |
| 631 | Twelveth floor |
| 632 | Terrace floor |
| 633 | Providing and fixing mild steel grill railing weighing 15Kilogram/One Square Metre. with PVC handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing PVC handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, etc. complete. Spec. One Number : As directed by Engineer in charge.Ground floor |
| 634 | Two Track Two Glass Shutter Window :Providing and fixing aluminium color anodized / powder Coated system sliding window of various sizes. Window will be made fromMalwin/YKK AP/Fenesta/Brandson, 25 to 27 mm slim series or equivalent System. Windows will be of specially extruded aluminium 2 Track - 2 Glass shutter window/ ventilator, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202screws. Glass shutter will be made from specially extruded aluminium section, glass considered is5 mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniformhairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete.Ground floor |
| 635 | First floor |
| 636 | Second floor |
| 637 | Four Track Three Glass + One Net Shutter Window: Providing & Fixing Aluminium System anodized / powder coated sliding windows of various sizes. Sliding will be made from Malwin/YKK AP/Fenesta/Brandson, 27 mm Slim series or equivalent system. Windows will be of specially extruded aluminium 4 Track -3 Glass + 1 net shutter with Bottom Fixed. Fixed Glass at Bottom as per drawings would be fixed on 40mm Casement Series Frame section & Single glass Glazing clip both having 45° Joints with special cleats & fixed to missionary by SS 202wood screws. The Sliding Window Track mounted on Special Square Aluminium section, The track fra me will be fixed to the masonry opening of windows with SS 202 wood screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 6 mm clear Toughened Glass. All shutters will be having 45° joints, joints will be fixed with specially developed clits to form uniform hairline joint. All Shutter will be fixed to the main frame with necessary double roller to have smooth & easy movement of the shutter. Shutters will have single point self pressing lock. Windows will be sealed with weather sealant from outer periphery,etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete.Ground floor |
| 638 | First floor |
| 639 | Second floor |
| 640 | Third floor |
| 641 | Fourth floor |
| 642 | Fifth floor |
| 643 | Sixth floor |
| 644 | Seventh floor |
| 645 | Eighth floor |
| 646 | Nineth floor |
| 647 | Tenth floor |
| 648 | Eleventh floor |
| 649 | Twelveth floor |
| 650 | Aluminium System Color Anodized Partly Fixed partly Openable Window : Providing and fixing aluminium system color anodized / powder coated Partly Fixed partly Openable window of various sizes. Casement will be made from Malwin/YKK AP/Fenesta/Brandson ,40 mm series or equivalent System. Windows will be of specially extruded aluminium section, joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 wood screws. Fixed glass casement will be made from specially extruded aluminum section, glass considered is5 mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniformhairline joint. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete.First floor |
| 651 | Third floor |
| 652 | Fifth floor |
| 653 | Seventh floor |
| 654 | Nineth floor |
| 655 | Eleventh floor |
| 656 | Openable Shutters/Windows in Structural/Curtain Glazing : Providing and fixing openable shutter in structural glazing work of 5mmtk tented toughened glass with frame workmade of aluminum RHSof size 64mm x 58mm color anodized as per design and drawing, aluminum sections should be confirming IS 63400 , glass pasted to frame work with 3M VHB tape and DOW CORNING 995 silicon sealantand gaps between glass panels should be filled by clear Dow CORNING 789 silicon weather proofing sealant , with good quality SS friction hinges, rubber gaskets handlesall necessary fasteners and accessories complete including With 24” Heavy S.S. Friction Hinges, Heavy Handles & 1\" window Handle Section of approved make, shade all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete.Ground floor |
| 657 | First floor |
| 658 | Three Track Three Glass Shutter Window :Providing and fixing aluminium system color anodized / powder coated sliding window of various sizes. Window will be made from Malwin/YKK AP/Fenesta/Brandson, 25 to 27 mm slim series or equivalent System. Windows will be of specially extruded aluminium 3Track - 3 Glass shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202screws. Glass shutter will be made from specially extruded aluminium section, glass considered is5 mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniformhairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. First floor |
| 659 | Three Track Two Glass + One Net Shutter Window :Providing and fixing aluminium system color anodized / powder coated sliding window of various sizes. Window will be made from Malwin/YKK AP/Fenesta/Brandson , 25 to 27 mm slim series or equivalent System. Window will be of specially extruded aluminium 3Track - 2 Glass + 1 net shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202screws. Glass shutter will be made from specially extruded aluminium section, glass considered is5 mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniformhairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete.First floor |
| 660 | Second floor |
| 661 | Third floor |
| 662 | Fourth floor |
| 663 | Fifth floor |
| 664 | Sixth floor |
| 665 | Seventh floor |
| 666 | Eighth floor |
| 667 | Nineth floor |
| 668 | Tenth floor |
| 669 | Eleventh floor |
| 670 | Twelveth floor |
| 671 | Solid Core Flush door Single leaf Providingandfixingfactorymadesolid coreflushdoorinsingleleaf35mmthick,decorativetypes,of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face Laminate on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessarybeads,mouldingandlipping,holdfasts,matfinishstainlesssteelfixturesfastenings,finishing withfrench-polish/waxingcomplete.(withoutdoorframe).(SampletobegotapprovedfromEx.Engineer before use) Commercial Hard Wood shutterFirst Floor |
| 672 | Second floor |
| 673 | Third floor |
| 674 | Fourth floor |
| 675 | Fifth floor |
| 676 | Sixth floor |
| 677 | Seventh floor |
| 678 | Eighth floor |
| 679 | Nineth floor |
| 680 | Tenth floor |
| 681 | Eleventh floor |
| 682 | Twelveth floor |
| 683 | Providing and laying Vitrified tiles (Matt and Antiskid Finish) in floor in 600milimeter x 1200milimeter sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid on 20 milimeter thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments excetra. The tiles must be cut with the zero chipping diametermond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.as directed by engineer-in-charge.Second floor |
| 684 | Third floor |
| 685 | Fourth floor |
| 686 | Fifth floor |
| 687 | Sixth floor |
| 688 | Seventh floor |
| 689 | Eighth floor |
| 690 | Nineth floor |
| 691 | Tenth floor |
| 692 | Eleventh floor |
| 693 | Twelveth floor |
| 694 | Providing and laying Vitrified tiles (Matt and Antiskid finish) in floor in 800milimeter x 1200milimeter sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid on 20 milimeter thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments excetra. The tiles must be cut with the zero chipping diametermond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.as directed by engineer-in-charge.First Floor |
| 695 | Aluminum Cladding:Providing and fixing Aluminum Jali Laser cut of 2mm thickness with pure polyester Matt finish exterior grade UV resistant powder coating / anodizing . The jali to be fixed to the sub framing (in our scope) using self drilling screws which shall not be visible in the elevation. The sub framing to be anchored to the main building using Anchor fasteners. Test report to be submitted for structural stability of the system for its self weight and wind load of 120kmph. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on site. Work shall be carried our includingall lead and liftsGround floor |
| 696 | First floor |
| 697 | Second floor |
| 698 | Third floor |
| 699 | Fourth floor |
| 700 | Fifth floor |
| 701 | Sixth floor |
| 702 | Seventh floor |
| 703 | Eighth floor |
| 704 | Nineth floor |
| 705 | Tenth floor |
| 706 | Eleventh floor |
| 707 | Twelveth floor |
| 708 | Terrace floor |
| 709 | Galvanised Fins: Providing and fixing 300x75mm rectangular metal Fins made from 0.7mm GI Sheet with infill of honecombing foam, powder coated with pure polyester Matt finish exterior grade UV resistant powder coating for 10 years warranty. The fins have tGround floor |
| 710 | First floor |
| 711 | Suppling and fixing Mural work in combination of alluminium perforated panel and sheet with powder coating or duco paint with lacquer coat for rust free and long life.Each design will be attached to a metal sheet as a background guard.The design will be in a relief work upto 75mm from the wall.Thickness of wall material will defer as per requrement.Job should be strictly workout as project architect guild line etc complete as per directed by Engineer In charge.Second floor |
| 712 | Providing & Fixing Aluminium colour anodized sliding & folding door 3 shutters having special patented frame & shutter profiles.Oter frame profles being fixed to the missionary with SS-202 screw shutters having 45 degree corner joints with special cleats for linear joints having 6mm toughned glass are installed in the frame structure with mortise lockat opening, Top & bottom pivots for sliding,but hinges for folding operation & subsidiary multi point locking & pop handle for additional security,complete. Ground floor |
| 713 | First floor |
| 714 | Providing and fixing double shutter glass door of required size of 12mm thick toughen glass frosting and edge polish as shown in the drawings or as directed,including all necessary fittings like hydraulic patch fittings, Top pivot,door handle,door lock,door stopper,door soft central 180 weather seal for door edges etc all complete as per architectural drawingsand directions of the Engineers-in- charge with all neccessary fastners and accessories complete .Ground floor |
| 715 | First floor |
| 716 | Alluminium System colour anodized Fixed window- Providing and fixng alluminium system colour anodized / powder coated fixed window of various sizes.Casement will be made from Malwin/YKK AP/Fenesta/Brandson ,40mm series or equivalent system window will be of specially extruded alluminium section,joints will be of 45 degree joints,joints will be fixed with specially developed clits.Track frame will be fixed to the masnory opening of windows with S S 202 wood screws.Fixed glass casement will be made from specially extruded alluminium section,glass considered is 5mm clear toughned glass. All shutter will be having 45 degree joints,joints will be fixed fixed with specially developed clits to form uniform hairline joints.All fixing screws will be of SS 202 windows will be sealed with weather sealant from outer periphery etc complete.Ground floor |
| 717 | First floor |
| 718 | Second floor |
| 719 | Third floor |
| 720 | Fourth floor |
| 721 | Fifth floor |
| 722 | Sixth floor |
| 723 | Seventh floor |
| 724 | Eighth floor |
| 725 | Nineth floor |
| 726 | Tenth floor |
| 727 | Eleventh floor |
| 728 | Twelveth floor |
| 729 | Providing and fixingCNC cutting MS jali having 4mm thick with powder coating with necessary fiitings required as per detailes provided by architect.Location of MS jali work will be as per drawing including lead ,lift etc complete as per directed by Engineer In charge.Second floor |
| 730 | Providing & fixing Luxalon SL4 84R plain panel sun louvers Of approved color consisting of panel 84mm wide 16mm deep x 0.6mm thick with round edges panel length up to 6 Mt coil coated on continues paint Line double baked & roll formed from enameled corrosion resistance. Aluminium Alloy AA3005 (Al. Mg.) for higher strength & good roll forming characteristics Panel shall be clipped to baked enameled aluminium SL-4 panel stringer of 33 mm wide & 86mm deep X 0.95 mm thick in a standard Length of 5 Mt made of double baked enameled Aluminium alloy AA5050 (Al. Mg.) black with cut-outs to hold the panel in a module of 86mm center to center at a distance of 1 Mt. The Carrier shall be fixed to suitable structure by means of rigid fixing details including Paint Finish : Aluminium panels shall be cromotised for maximum bond between metal & paint enameled twice under high temperature one side with full primer & luxacoat finish. The other side (Inner side) with a primer coat & skin coat on a continuous paint line etc.complete as directed by Engineer-in-charge.Ground floor |
| 731 | First floor |
| 732 | Providing ,fixing,testing and commisioning of turbo ventilators of approved make of size 24\" self propelled fans having stainless steel 430 grade body with approximate weight 4.85 Kg., having a CFM-7KM per hours-2440 with blade length 360mm wings of 80mm. including cutting roofing sheet,making the joints water tight,including all quality fastenings,fixing with self tapping screws from Buildtex, internal butt strap inlayed gasket,metal washers and Neoprene/EPDM washers,scaffoldings etc. complete. Location of Turbo vent as per drawing etc. complete. (Turbo vent should be Self-lubricating bearing) Third floor (Terrace Floor) |
| 733 | S.S. Railing : Providing and Fixingmatt finished stainless steel (Grade 304) railing with 60milimeter x 40milimeter and 1.6milimeter thick pipe as handrail at top, 40milimeter x 8milimeter vertical patti placed at 1148 milimeter center to center, 40milimeter x 8milimeter horizontal patti placed at bottom 100 milimeter above the flooring,12milimeter diametermeter pipe placed vertically in between handrail and bottom patti at 150milimeter c/c and 75milimeter c/c alternately as shown in the drawing. including buffing, fabricating fixtures and fastening includingbase or cover plate of appropriate size as directed by Engineer in charge excetra. Complete.Ground floor |
| 734 | First floor |
| 735 | Second floor |
| 736 | Third floor |
| 737 | Fourth floor |
| 738 | Fifth floor |
| 739 | Sixth floor |
| 740 | Seventh floor |
| 741 | Eighth floor |
| 742 | Nineth floor |
| 743 | Tenth floor |
| 744 | Eleventh floor |
| 745 | Twelveth floor |
| 746 | Terrace floor |
| 747 | Providing and fixing glass door size 1.0meter/1.2meter x 2.7meter single leaf shutter of 12 milimeter thick toughen glass frosting and edge polish as shown in the drawings or as directed , including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle,door lock, door stopper, door soft central 180 weather seal for door edges excetra. complete as directed by Engineer -IN-Charge Ground floor |
| 748 | First floor |
| 749 | Providing and fixing 12 milimeter thick toughen glass and edge polish as shown in the drawings or as directed, including all necessary fittings like Upper glazing profile, bottom lockingglazing profile, standard gasket for profile, locking Gasket 12milimeter, door soft central 180 weather seal for glass edges as per drawingshaving glass fixing sections at all sides concealed in partitions excetra. complete as directed by Engineer -IN-Charge. gaps between glass panels should be filled by clearsilicon weather proofing sealant , EPDM gaskets, handlesall necessary fasteners and accessories complete.as directed by engineer-in-charge.Ground floor |
| 750 | First floor |
| 751 | Bamboowood14mm thick Tile Flooring including quarter round & door reducer - Providing &fixingin position Phenol bonded Epitome Bamboowood flooring with planks of sizes14mmthick,1800mm length (minimum) and 130mm wide (minimum), in approved colour, textureandfinish,having Performance Appraisal Certificate (PAC) issued by Buildingmaterials & Technology Promotion Council(BMTPC).Theflooringshallbefixedwith tongue and groove interlocaking system, with 2mm underlayassoundabrobingandmoisturebarrierandunderlaymentof4mm thickexpandedpolyethylene foam sheets having density 40Kilogram/cum, over preparedsurface withnecessary quarter round planks of size 1900mm x18mmanddorrreducerofsize1900mmx44mm,whereverrequired.TheEpitome Bamboowoodplanksshallhaveminimumdensityof1000Kilogram/cum&minimum Hardness1000 Kilogramf.withEcofriendlyUVcoating,allcompleteasperdirectionof Engineer in-charge.Second floor |
| 752 | Bamboowood 14mm thick wall Skirting - Providing & fixing in position Phenol bondedEpitome Bamboowood in wall skirting with planks of sizes 14mm thick, 1900mm length(minimum) and 85mm wide (minimum), in approved colour, texture and finish, havingPerformance Appraisal Certificate (PAC) issued by Building materials & TechnologyPromotion Council (BMTPC). The skirtingshallbefixedSSscrews&rawlplugs,over underlayment of 4mm thick expanded poly ethylene foam sheets having density 40Kilogram/cum,overpreparedsurface.TheEpitome Bamboowood planks shall haveminimum density 1000 Kilogram/cum & minimum Hardness 1000 Kilogramf.withEco friendly UV coating, all complete as per direction of Engineer in-charge.Second floor |
| 753 | Providing andfixing Indian teak woodplankceiling 20mm thickplainundersidetonguedand grooved including ironscrews,scaffolding,ifnecessary,including oneprimercoaton under side and one coat ofcoal tar on upper side etc. complete.First floor |
| 754 | Second floor |
| 755 | Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during andafterexcavationasmayberequiredbyusing3.0BHPpumpetc.complete.(priorapprovalof Superintending Engineer will be necessary) |
| 756 | Providing and fixing of Terracotta desiner jali of Nuvocottoor Equivalent make of size having 200x200x60mm as per manufacturer finished with approved colour and pattern . The blocks shall be fixed by suitable system by using mortar or special ready mix mortar or adhesive per manufacturer guidelines and specifications with suitablable thickness of joining material, size and spacing to withstand the structural design criteria specified, supported or locked by beams or columns as per design height criteria of the cladding as per manufacturer technical specification,Cladding joints should be with as per design and drawingsincluding cutting, jointing, fixing, scaffolding, cleaning, lead, lifts, handling etc. complete as shown in design, drawings and specifications as directed by engineer & In charge.Sample needs to get approved from project architect before execution of work.as directed by engineer-in-charge |
| 757 | Providingand fixingbituminouspad 25mmthick forexpansion jointsin retainingwall,compound wall etc. complete. |
| 758 | ProvidingandfixingheavydutyinterlockingconcreteColouredpavingblocksof80mm thickness of having a strength of 300 Kilogram/Sq.cm. of approvedquality andshape ona bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete |
| 759 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader/ Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - III Material |
| 760 | Providing,laying,spreadingandcompactingstoneaggregatesofspecificsizestowaterboundmacadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying andbroomingrequisitetypeofscreening/bindingMaterialstofilluptheintersticesofcoarseaggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I(Using Screening Type A (13.2) mm Aggregate) |
| 761 | Providing,laying,spreadingandcompactingstoneaggregatesofspecificsizestowaterboundmacadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying andbroomingrequisitetypeofscreening/bindingMaterialstofilluptheintersticesofcoarseaggregate, watering andcompacting withvibratory roller to the requireddensity. By Mechanical Means- Grading II(Using Screening Type B (11.2 mm) Aggregate) |
| 762 | Construction of dry lean cement concrete Sub- base over aprepared sub-gradewith coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding25mm,,cementcontentnottobelessthan150kg/cum,optimummoisturecontenttobe determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved byEngineer-in-charge , compacting withvibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 763 | Providing and laying in-situM30 Grade unreinforced plain cement concretepavementwithmax 20% fly Ash ( Fly-ash upto 20% by weight of Cement) over a prepared sub base with 43 grade cement , coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradationas per Table 600-3 of MORTH Specification 2013, mixed in a Tilting type Concrete Mixer as per approved mix design, admixtures, spreading, laying compacting and finished in a continuous operation without paver machine, finishing to lines and gradesas directed by Engineer-in-charge and curingby curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre,admeasuring80mmatbottomand40mm attopwith depthof75mm andmaintainingthesame throughout curing period by any other method approved by Engineer-in-charge. |
| 764 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. .in concrete slab using concrete cutting machinewithdiamondstuddedsawwithin48hoursofcastingofbay/slabetc.completeincluding subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineerincharge. |
| 765 | Providingtocontractionjointspolysuphidesealent(Pouringgrade)confirmingtoBS:5212-1989into sawedgroovewidenedattopforsealentreservoirofspecifiedsizeandshapeasperdetaileddrawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger thanthe initial 3 mm.to 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints withwaterjet/aircompressorandallowing jointto becomethoroughlydrybefore sealentisappliedand applying primer.(A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide) rates) |
| 766 | Providingandlaying125micronLowDensityPolyethylene(LDPE)sheetconfirmingtoIS3395:1997 below concrete pavement including all materials and labour complete. |
| 767 | Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from departmental Land) |
| 768 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 769 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 900mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 770 | Providing and fixing in position TMT FE 500, 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directedincluding handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete. |
| 771 | Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/Cand wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. |
| 772 | Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb with gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching andMixing Plant |
| 773 | Providing and fixing mild steel grill railing weighing 15Kilogram/One Square Metre. with PVC handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing PVC handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, etc. complete. Spec. One Number : As directed by Engineer in charge. |
| 774 | Providing and installating the Statue of maximum size 2m wide x 2m long x 3m high of granite stone material as per the design and drawing provided by the Architect including all required cutting, grinding, finishing, polishing etc. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on site. Work shall be carried our includingall lead and lifts etc complete as directed by Engineer-In-Charge. |
| 775 | Providingandlayingintrenches50mmdai.CPVCpipeincludingnecessaryexcavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line ifnecessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 776 | Providingandlayingintrenches50mmdia.heavygradehavingembossedasISIMark galvanised iron pipes of 6.33 Kilogram/metre necessary fitting remaking good the demolished portionwithfilling trenchesandwithprimer ofanti-corrosive oilpaint ,2 coatscomplete. Including removing existing pipe line if necessaryandconveying andstacking the same in PWD chowky or as directed etc. complete. |
| 777 | Providingandlayingintrenches80mmdia.heavygradehavingembossedasISIMark galvanised iron pipes of 10.15 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 778 | Providing,constructingandfixing 250mmdia.InspectionchambermadeupofUPVC material of thickness 3.5 mm and height of 259 mm with inlet and outlet of 110 mm dia. with 75 mm dia. U Trap, Ultra shaft pipe of Upvc material having height of 470 mm and fixing Ultra 250 mm dia. UPVC cover and frame in 150 mm thick in c.c.1:2:4, having crushed sand bedof100mmthickofsize550mmdia.Includingexcavationandrefillingthesidesof chamberbycrushedsandcushioning150mmthickness,connectingallrequiredUPVC fittings with rubber lubricant etc. complete. |
| 779 | Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. |
| 780 | Providing , constructing and fixing600 mm dia. Inspection chamber made up of Polypropylene/polyethylenematerialHaving315mmdiameterinlet(s)/outletsandwith eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of5mmand600mminheight,withinbuiltshaftachievetheinvertdepthaspersite condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete. |
| 781 | Providing , laying and fixing ,jointingEco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. |
| 782 | Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such abends,tees,coupler,etc,jointingwith rubberlubricantincludingnecessary excavation, trench refilling with selective excavated materialetc. complete. |
| 783 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 784 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 785 | Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 786 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 787 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 788 | Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECOwith prior approval of concerned Superitending Engineer. |
| 789 | RWH - Recharge PitProviding andconstructing rechargepitof2.0m deepand1.0m diaofpre-castRCCrings with6.5\"diax25mdeepborewellatthefloorofrechargepitincludinginstallationof combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mmthicksidefillingaroundoutsideofRCCrings(annularspace)with40mmsize bouldersincludingfillingofrechargepitupto0.5mdepthwith25-75mmcleanwashed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.)includingnetlonmeshbetweeneachgravel/fineaggregate(naturalsand/crushedsand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation& backfilling as shownin the drawing.The rate shall be inclusive of alllabour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All materialshouldbeofapprovedmake.Allworkscompleteasperthedrawing,technical specification and direction of the Engineer in charge. |
| 790 | Providing and constructing on sewer, B.B. masonry circular manhole with concentric cone 1.2 M dia. at bottom and 0.5 M dia. at top and upto a depth of 2.00 M with 23 cm brick work in CM 1:4 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in C.C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C. frame and cover of 56 cm dia.etc. complete as directed by Engineerin-charge. |
| 791 | Providing and constructing on sewer, B.B. masonry circular manhole concentric cone 1.5 M dia. at bottom and 0.5 M dia. at top and upto a depth of 5.00 M with 23 cm brick work, upto depth of 2 M from top and 35 cm thick brick work for balance depth in CM 1:4 proportion with 20 mm thick smooth plaster on both sides in CM 1:2 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in C.C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C frame and cover of 56 cm dia. etc. complete as directed by Engineerin-charge.Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-charge. |
| 792 | As above of 90 x 60 cm internal size and depth upto 1.2 M with 90 x 60 cm size CI manhole frame and cover of 50 kg.Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-charge. |
| 793 | As above of 90 x 90 cm internal size and depth upto 1.2 M with 53 cm dia CI manhole frame and cover of 90 kg. fixed in RCC slab.C P & Sanitary Fixtures & Fittings |
| 794 | Providing and fixing White Opal series European type wall-hung of size 400 mm X 370 mm X 575mm with approved make flush valveincluding soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.Ground floor |
| 795 | First floor |
| 796 | Second floor |
| 797 | Third floor |
| 798 | Fourth floor |
| 799 | Fifth floor |
| 800 | Sixth floor |
| 801 | Seventh floor |
| 802 | Eighth floor |
| 803 | Nineth floor |
| 804 | Tenth floor |
| 805 | Eleventh floor |
| 806 | Twelveth floor |
| 807 | Providing and fixingOrissa Pan of size 580 X 445 X 260 mm with approved make flush valve including trap, C.I. soil andvent pipe upto outside face ofwall including 100mm dia.C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge.Ground floor |
| 808 | Providing and fixing White wash basin with half pedestal of size 515mm X 615mm X 460 mm including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall.Ground floor |
| 809 | First floor |
| 810 | Second floor |
| 811 | Providing and fixingOval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm sizewith pillarcock,C.P.Angularstopcock,longthreadofapprovedmakecontinental includingSSbottletrapof necessarypipeconnectionuptotheoutsidefaceofthewall, havingTelephonicBlack/ColourGraniteof180mmthickfixedonBlackKadappa Framework, etc. Complete as directed by Engineer in charge.First floor |
| 812 | Second floor |
| 813 | Third floor |
| 814 | Fourth floor |
| 815 | Fifth floor |
| 816 | Sixth floor |
| 817 | Seventh floor |
| 818 | Eighth floor |
| 819 | Nineth floor |
| 820 | Tenth floor |
| 821 | Eleventh floor |
| 822 | Twelveth floor |
| 823 | Providing and fixing White glazed urinal with Pressmatic auto closing valvehaving flow rate up to 4.0 Litr/Minute of Jaquar / Cera / Hindware / Perryware or equivalent make with P.V.C. waste pipewith fittingarrangement etc.complete as directed by Engineer in charge. ( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.)Ground floor |
| 824 | First floor |
| 825 | Second floor |
| 826 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.Ground floor |
| 827 | First floor |
| 828 | Second floor |
| 829 | Third floor |
| 830 | Fourth floor |
| 831 | Fifth floor |
| 832 | Sixth floor |
| 833 | Seventh floor |
| 834 | Eighth floor |
| 835 | Nineth floor |
| 836 | Tenth floor |
| 837 | Eleventh floor |
| 838 | Twelveth floor |
| 839 | Providing and fixing C.P. BIB cock with wall flange of approvedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge.Ground floor |
| 840 | First floor |
| 841 | Second floor |
| 842 | ProvidingandfixingC.P.2WayBIBcockwithwallflange ofapproved makeincluding necessary sockets/ union nut etc. complete as directed by Engineer in charge.Ground floor |
| 843 | First floor |
| 844 | Second floor |
| 845 | Third floor |
| 846 | Fourth floor |
| 847 | Fifth floor |
| 848 | Sixth floor |
| 849 | Seventh floor |
| 850 | Eighth floor |
| 851 | Nineth floor |
| 852 | Tenth floor |
| 853 | Eleventh floor |
| 854 | Twelveth floor |
| 855 | Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete.Ground floor |
| 856 | First floor |
| 857 | Second floor |
| 858 | Third floor |
| 859 | Fourth floor |
| 860 | Fifth floor |
| 861 | Sixth floor |
| 862 | Seventh floor |
| 863 | Eighth floor |
| 864 | Nineth floor |
| 865 | Tenth floor |
| 866 | Eleventh floor |
| 867 | Twelveth floor |
| 868 | Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalentmake including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) First floor |
| 869 | Second floor |
| 870 | Third floor |
| 871 | Fourth floor |
| 872 | Fifth floor |
| 873 | Sixth floor |
| 874 | Seventh floor |
| 875 | Eighth floor |
| 876 | Nineth floor |
| 877 | Tenth floor |
| 878 | Eleventh floor |
| 879 | Twelveth floor |
| 880 | Providing and fixingsink cock with regular swinging spout (Wall / floor Mounted Model) with wall flange having flow rate up to6.0 Litr/Minute of Jaquar / Cera / Hindware / Perryware or equivalentmake incluidng other necessary fitting, etc. complete.Ground floor |
| 881 | First floor |
| 882 | Second floor |
| 883 | Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mmdia. nickel plated towel rod etc. complete.Ground floor |
| 884 | First floor |
| 885 | Second floor |
| 886 | Third floor |
| 887 | Fourth floor |
| 888 | Fifth floor |
| 889 | Sixth floor |
| 890 | Seventh floor |
| 891 | Eighth floor |
| 892 | Nineth floor |
| 893 | Tenth floor |
| 894 | Eleventh floor |
| 895 | Twelveth floor |
| 896 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BARof IZE-600MM (H) X600MM (D) and 32MM DIA. and thicknessmm of the approved brand and make.27c) Straight grab bar (2 NOS)Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make.Ground floor |
| 897 | First floor |
| 898 | Second floor |
| 899 | Providingandfixing75mmdiastabiliserpipe/P.V.C.soilvent/wastepipeandwith necessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Ground floor |
| 900 | First floor |
| 901 | Second floor |
| 902 | Third floor |
| 903 | Fourth floor |
| 904 | Sixth floor |
| 905 | Seventh floor |
| 906 | Eighth floor |
| 907 | Nineth floor |
| 908 | Tenth floor |
| 909 | Eleventh floor |
| 910 | Twelveth floor |
| 911 | Terrace floor |
| 912 | Providingandfixing100mmdiastabiliserpipe/P.V.C.soilvent/wastepipeandwith necessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Ground floor |
| 913 | First floor |
| 914 | Second floor |
| 915 | Third floor |
| 916 | Fourth floor |
| 917 | Fifth floor |
| 918 | Sixth floor |
| 919 | Seventh floor |
| 920 | Eighth floor |
| 921 | Nineth floor |
| 922 | Tenth floor |
| 923 | Eleventh floor |
| 924 | Twelveth floor |
| 925 | Terrace floor |
| 926 | ProvidingandfixingP.V.C.Rainwaterpipesof160mm & above (preffered 250mm)outerdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.Ground floor |
| 927 | First floor |
| 928 | Second floor |
| 929 | Third floor |
| 930 | ProvidingandfixingP.V.C.Rainwaterpipesof160mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolvent cementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.Ground floor |
| 931 | First floor |
| 932 | Second floor |
| 933 | Third floor |
| 934 | Fourth floor |
| 935 | Fifth floor |
| 936 | Sixth floor |
| 937 | Seventh floor |
| 938 | Eighth floor |
| 939 | Nineth floor |
| 940 | Tenth floor |
| 941 | Eleventh floor |
| 942 | Twelveth floor |
| 943 | Terrace floor |
| 944 | Providingandfixing15cmrigidPVCNahanitrapincludingPVCgrating ,bend,connectingpieceofUPVCpipeuptotheoutsidefaceofwall,makingthegood damaged surface and testing etc. complete (Prior approval of sample and brand by Ex. Engr. is necessary before use)Ground floor |
| 945 | First floor |
| 946 | Second floor |
| 947 | Third floor |
| 948 | Fourth floor |
| 949 | Fifth floor |
| 950 | Sixth floor |
| 951 | Seventh floor |
| 952 | Eighth floor |
| 953 | Nineth floor |
| 954 | Tenth floor |
| 955 | Eleventh floor |
| 956 | Twelveth floor |
| 957 | Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground floor |
| 958 | First floor |
| 959 | Second floor |
| 960 | Third floor |
| 961 | Fourth floor |
| 962 | Fifth floor |
| 963 | Sixth floor |
| 964 | Seventh floor |
| 965 | Eighth floor |
| 966 | Nineth floor |
| 967 | Tenth floor |
| 968 | Eleventh floor |
| 969 | Twelveth floor |
| 970 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground floor |
| 971 | First floor |
| 972 | Second floor |
| 973 | Third floor |
| 974 | Fourth floor |
| 975 | Fifth floor |
| 976 | Sixth floor |
| 977 | Seventh floor |
| 978 | Eighth floor |
| 979 | Nineth floor |
| 980 | Tenth floor |
| 981 | Eleventh floor |
| 982 | Twelveth floor |
| 983 | Terrace floor |
| 984 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground floor |
| 985 | First floor |
| 986 | Second floor |
| 987 | Third floor |
| 988 | Fourth floor |
| 989 | Fifth floor |
| 990 | Sixth floor |
| 991 | Seventh floor |
| 992 | Eighth floor |
| 993 | Nineth floor |
| 994 | Tenth floor |
| 995 | Eleventh floor |
| 996 | Twelveth floor |
| 997 | Terrace floor |
| 998 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground floor |
| 999 | First floor |
| 1000 | Second floor |
| 1001 | Third floor |
| 1002 | Fourth floor |
| 1003 | Fifth floor |
| 1004 | Sixth floor |
| 1005 | Seventh floor |
| 1006 | Eighth floor |
| 1007 | Nineth floor |
| 1008 | Tenth floor |
| 1009 | Eleventh floor |
| 1010 | Twelveth floor |
| 1011 | Terrace floor |
| 1012 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.Ground floor |
| 1013 | First floor |
| 1014 | Second floor |
| 1015 | Third floor |
| 1016 | Fourth floor |
| 1017 | Fifth floor |
| 1018 | Sixth floor |
| 1019 | Seventh floor |
| 1020 | Eighth floor |
| 1021 | Nineth floor |
| 1022 | Tenth floor |
| 1023 | Eleventh floor |
| 1024 | Twelveth floor |
| 1025 | Terrace floor |
| 1026 | Providingandfixingscrewdownfor20mmdia.wheeledstoptapofbrassincluding necessary sockets/union nut complete.Ground floor |
| 1027 | First floor |
| 1028 | Second floor |
| 1029 | Third floor |
| 1030 | Fourth floor |
| 1031 | Fifth floor |
| 1032 | Sixth floor |
| 1033 | Seventh floor |
| 1034 | Eighth floor |
| 1035 | Nineth floor |
| 1036 | Tenth floor |
| 1037 | Eleventh floor |
| 1038 | Twelveth floor |
| 1039 | Providingandfixingscrewdownfor25mmdia.wheeledstoptapofbrassincluding necessary sockets/union nut complete.Ground floor |
| 1040 | First floor |
| 1041 | Second floor |
| 1042 | Third floor |
| 1043 | Fourth floor |
| 1044 | Fifth floor |
| 1045 | Sixth floor |
| 1046 | Seventh floor |
| 1047 | Eighth floor |
| 1048 | Nineth floor |
| 1049 | Tenth floor |
| 1050 | Eleventh floor |
| 1051 | Twelveth floor |
| 1052 | Providingandfixingscrewdownfor32mmdia.wheeledstoptapofbrassincluding necessary sockets/union nut complete.Ground floor |
| 1053 | First floor |
| 1054 | Second floor |
| 1055 | Terrace floor |
| 1056 | Providingandfixingscrewdownfor40mmdia.wheeledstoptapofbrassincluding necessary sockets/union nut complete.Ground floor |
| 1057 | First floor |
| 1058 | Second floor |
| 1059 | Third floor |
| 1060 | Fourth floor |
| 1061 | Fifth floor |
| 1062 | Sixth floor |
| 1063 | Seventh floor |
| 1064 | Eighth floor |
| 1065 | Nineth floor |
| 1066 | Tenth floor |
| 1067 | Eleventh floor |
| 1068 | Twelveth floor |
| 1069 | Terrace floor |
| 1070 | Providing andfixing 20mm diameterwatermeterwithnon-returnvalve includingstrainer, sockets/ union nut including water meter box making locking arrangement and lock. (without chamber).First floor |
| 1071 | Providing andfixing 50mm diameterwatermeterwithnon-returnvalve includingstrainer,sockets/unionnutandincludingwatermeterboxmakinglockingarrangementandlock. [without chamber]Ground floor |
| 1072 | Providing andfixing 80mm diameterwatermeterwithnon-returnvalve includingstrainer, sockets/unionnutandincludingwatermeterboxmakinglockingarrangementandlock.[Without chamber].Ground floor |
| 1073 | Providing andfixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete.Terrace floor |
| 1074 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes of 65mm nominal inner dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. |
| 1075 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes of 80 mm nominal inner dia Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. |
| 1076 | Providing and Fixing it in position, Alighning to correct position, testing and commissioning of CP brass Grating (Viking 41615) of Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating. including setting in floor with cement motor to match with floor finish as per architect requirement complete including all accessories. All work Complete as per direction of the Engineer-in-Charge. |
| 1077 | Providing and Fixing it in position, Alighning to correct position, testing and commissioning of CP brass Gratingof Close on Top type (Viking 45290) with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating. including setting in floor with cement motor to match with floor finish as per architect requirement complete including all accessories. All work Complete as per direction of the Engineer-in-Charge. |
| 1078 | Providing and Fixing it in position, Alighning to correct position, testing and commissioning of CP brass P Trap 40mm Size for wash basin, Urinal & Kitchen Sinks. (Viking-5898 V6 H12)with all necessary fixtures and fittingetc complete as directed by the Engineer-in-Charge. (Fixtures and fittings as per Approved C.P & Sanitary Product sheet). All work Complete as per direction of the Engineer-in-Charge. |
| 1079 | Providing, fixing, testing and commissioning of Brass Housing Pressure Reduce Valve with balanced seat, standard pattern, set point scale, high quality synthetic material valve insert, SS wire mesh, NBR diaphragm, NBR seats, pressure gauge, complete as required in water supply drop pipes.To be installed inside shaft, on-line type. Pressure range Complete as per direction of the Engineer-in-Charge.i) 25 mm dia |
| 1080 | ii) 32 mm dia |
| 1081 | iii) 40 mm dia |
| 1082 | iv) 50 mm dia |
| 1083 | v) 65 mm dia |
| 1084 | Providingandfixing 600 mm long MS hot dip galvanized Puddel Flange fabricated out of 6 mm thick MS plates of suitable size and pipe shall be confirming to IS:1239 heavy class pipes properly fixed in walls / top slab of tanks.The entire fittings shall be hot dipped galvanized after fabrication.Length shall be minimum 600 mm or wall thickness plus 200 mm on either side (which ever is more). Each Puddle shall be flange at outer side for connection of pipe / fittings.All work Complete as per direction of the Engineer-in-Charge.i) 25 mm dia |
| 1085 | ii) 50 mm dia |
| 1086 | iii) 65mm dia |
| 1087 | iv) 80mm dia |
| 1088 | v) 100mm dia |
| 1089 | vi) 150mm dia |
| 1090 | vii) 200mm dia |
| 1091 | Preparation of Lawns (Depth 30Cm)Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.36a) |
| 1092 | Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR 2022-23 Items of garden work,Sr No.36b) |
| 1093 | Providing on site required variety of lawn (free from weeds /diesease etc.) Cynadon/ paspalum/ selection for 1 One Square meter. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work,Sr No.46) |
| 1094 | Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms.(As per P&G DSR 2022-23 Items of garden work,Sr No.3) |
| 1095 | Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work,Sr No.13) |
| 1096 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover.(1/10 of semiskilled labour)(As per P&G DSR 2022- 23 Items of garden work,Sr No.23) |
| 1097 | Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/ selection)(As per P&G DSR 2022-23 Items of garden work,Sr No.28) |
| 1098 | Preparation of Shrubbery(Depth 30.00 Cm) -Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:- Murraya(Kamini);Bag Size 7\"\" x 8\"\",(plants list) 1(a) serial no 15. |
| 1099 | Maintenance of Newly Developed Shrubs Area. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31) |
| 1100 | Plantation of Trees (Ht.1-2 mtrs)Supplying on site fresh Garden soil (i. e. 3 part soil) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 0.60 x 0.60 x 0.60m (consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.44a) |
| 1101 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 0.60 x 0.60 x 0.60m (consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.44b) |
| 1102 | Providing on site required variety of Tree (free from weeds /diesease etc.) 30 cms. apart c/c.Name:- Bahava;Bag Size 13 x13\"\", ht 6-8\"(plants list sr no1,item no 5B) |
| 1103 | Excavation pit size 0.60 x 0.60 x 0.60m for planting small & medium ornamental plants/ large flowering/ shady trees (plant height 1 to 2 mtr.)/ palm varieties upto height 1 to 2 mtrs. in earth, soil of all types, soft murum, including removing the excavated & unwanted materialup to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.11) |
| 1104 | Filling fresh garden soil / silt & manure in excavated pit size area of 0.60 x 0.60 x 0.60m (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.21) |
| 1105 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting required plant species as directed etc. complete for required pit size 0.60 x 0.60 x 0.60m. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work,Sr No.26) |
| 1106 | Maintenance of Newly Planted tree varieties having height 1mtr. - 2mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.34) |
| 1107 | Electrical Work - Sub - Work No. 1:- Name of work:- 115650/23-24 subwork -A Providing EI, Transformer, DG set to Proposed Construction of Chhatrapati Shahu Maharaj Research, Training & Human Development Institute (SARTHI) Sub centre at ITI Campus, Aundh, PuneSupplying, installing, testing and commissioning 11 kV 630A, indoor type ring main unit with 1 VCB & 2 LBS with internal arc compliance complete erected on provided CC foundation/MS channels/trench, etc., as per specification no SW-HTS / RMU |
| 1108 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 630kVA, Mineral oil immersed and naturally cooled Intdoor type, Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating, using type Awinding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 1860 Watts at 50% load, 5300 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. |
| 1109 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 250 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 54.89 Ltr/hr @75% loading. Both the engineand alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 480 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG |
| 1110 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 250 kVA up to 320 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 1111 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT( ROUND ARMOURED)NOTE 2 2) For round wire armouring increase rateFor 11 kV (E) by 28% |
| 1112 | Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT |
| 1113 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 1114 | Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A, VA10 or 15, Class 0.5S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.5 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation. |
| 1115 | Supplying and erecting 200 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC |
| 1116 | Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) |
| 1117 | Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer. |
| 1118 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV |
| 1119 | Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete |
| 1120 | Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete |
| 1121 | Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI |
| 1122 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 1123 | Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessaryGIclampsfixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP). |
| 1124 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 1125 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 1126 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 1127 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1128 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1129 | Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1130 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1131 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1132 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1133 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 1134 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 1135 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) asper specification no. SW-SWR/MCBDB |
| 1136 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 1137 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 1138 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 1139 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 1140 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 1141 | Supplying and erecting blanking plate of suitable size on MCBDB. |
| 1142 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 1143 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 1144 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 1145 | Supplying, erecting & commissioning 2 pole RCCB40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 1146 | Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 1147 | Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 1148 | Supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 V 50 cycle AC having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16A to use independently or in conjunction with contactor. |
| 1149 | Supplying and erecting four pole power contactor 430 V, 16 A for time switch complete erected on provided wooden block/ box, with necessary materials. |
| 1150 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 1151 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 1152 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 1153 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 1154 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 1155 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 1156 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1157 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1158 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1159 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1160 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1161 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1162 | Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX |
| 1163 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 1164 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 1165 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit |
| 1166 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1167 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (NOTE 3) |
| 1168 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BW |
| 1169 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BW (NOTE 3) |
| 1170 | Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1171 | Supplying and erecting mains with 3x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1172 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 1173 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 1174 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete |
| 1175 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 1176 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 1177 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete |
| 1178 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 1179 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 1180 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 1181 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 1182 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 1183 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground |
| 1184 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 1185 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 1186 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW |
| 1187 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 1188 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 1189 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 1190 | Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 1191 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. (576 + 288 Toilet) |
| 1192 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.(132 ROOMS x 2) |
| 1193 | Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 1194 | Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clipscomplete with 3 years warranty. |
| 1195 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 1196 | Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f.>0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty |
| 1197 | Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. |
| 1198 | Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life ofminimum 25000 hrs. with overheating protection with 2 years warranty. |
| 1199 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 1200 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 1201 | upplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% without IR remote control/compatible speedregulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF NOTE |
| 1202 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 1203 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 1204 | Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS |
| 1205 | Supplying and erecting 12V/17Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 1206 | Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS |
| 1207 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 1208 | (New) Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75 Nos.)and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remotemonitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract asper Specification no. ESD-RT-ONG. |
| 1209 | Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 1210 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). |
| 1211 | Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2. |
| 1212 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 1213 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3.5 core 25 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1214 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 4 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (ExcludingMCCBs) |
| 1215 | Supply, Installation, testing and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundationPanel Details :- Name - MAIN LTFPDuty -Duty: Indoor Type (IP 42)Incomer-1 Nos of 1000A FP MDO ACB,Busbar - 1000A TPNN Al Busbar Outgoings - 4 Nos of 630A TPN HRC FUSE WITH NEUTRAL LINK, |
| 1216 | Supply, Installation, testing and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundationPanel Details :- Name - DG DIST. PANELDuty -Duty: Indoor Type (IP 42)Incomer-4 Nos of 630A FP MCCB,WITH LSIG µPBASED RELEASEBusbar - 630A TPNN Al Busbar Outgoings - 3 Nos of 63A TPN MCCB,2 Nos of 125A TPN MCCB,3 Nos of 160A TPN MCCB,1 Nos of 200A TPN MCCB, 2 Nos of 250A TPN MCCB,5 Nos of 315A TPN MCCB, 2 Nos of 400A TPN MCCB, |
| 1217 | Supply, Installation, testing and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundationPanel Details :- Name - Utility Panel Girls and Boys HostelDuty -Duty: Indoor Type (IP 42)Incomer-1 Nos of 315A FP MCCB,Busbar - 315A TPN Al Busbar Outgoings - 11 Nos of 40A TPN MCB, 1 Nos of 100A TP MCCB 3 Nos of 16A TPN MCB, 1 Nos of 32A TPN MCB, 2 Nos of 63A TPN MCB, |
| 1218 | Supply, Installation, testing and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundationName - Utility Panel Office BldgDuty -Duty: Indoor Type (IP 42)Incomer-1 Nos of 200A FP MCCB, Busbar -200A TPN Al Busbar Outgoings - 3 Nos of 32A TP MCB, 5Nos of 40A TP MCB 6 Nos of 25A TPN MCB, 4 Nos of 10A SPN MCB,4 Nos of 63A TPN MCB, |
| 1219 | Supply, Installation, testing and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation Name - Utility Panel Museum BldgDuty -Duty: Indoor Type (IP 42)Incomer-1 Nos of 160A FP MCCB, Busbar -200A TPN Al Busbar Outgoings - 8 Nos of 40A TPN MCB,7 Nos of 25A TP MCB,1 Nos of 32A TPN MCB4 Nos of 10A SP MCB |
| 1220 | Supply, Installation, testing and commissioning of cubical type MV Panel conform toIEC:61439-I as pertechnical specifications,single line diagram & approval of Drawings prior to manufacturing, packed in wooden crates with PVC sheets inner packing, transport to site, compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. erected in 14 gauge CRCA sheet and surface treated with phosphating seven tank process and duly powder coated with MSEDCl approved color, feeder piller should be with supporting angles, self-locks, gasket and slanting top to be erected on provided foundationHVAC Panel Incomer: 200A FP MCCB Busbar: 200A AL busbar.Outgoing: 7 No of 40A FP MCB3 Nos 25A FP MCB1 Nos 16A FP MCB,2 Nos 63A FP MCB |
| 1221 | Supply & erecting KL-4263 Nebula Micro - Spike, Dimension : 93 x 90 x 320mm, Wattage : 3W LED.KL-8295 - Visor - Nebula Micro Front Cover, Dimension : Ø45x58mm. including driver, having mounting arrangement with board for surface type or spring loaded mounting clipsIP65 & IK10 class having extrusion aluminium housing withpolycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90,operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of25,000 Hrs. at L50B50, including driver completewith 3 years warranty. |
| 1222 | Supply & Erecting KL-3237 Power Graze - Surface, OAD : 1210 x 53 x 71mm, Wattage : Upto 36W LED.including driver, having mounting arrangement IP65 & IK10 class having extrusion aluminium housing withpolycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90,operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of25,000 Hrs. at L50B50, including drivercomplete with 3 years warranty. |
| 1223 | Supply & Erecting KL-3277 Linear In-Ground Luminaire - Wall Grazer, COD : 1015 x 68 x 80mm, Wattage : 24W LED, Non Integral. including driver, having mounting arrangement IP65 & IK10 class having extrusion aluminium housing withpolycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90,operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as perspecification No FG-ODF/FLS2. with 3 years warranty. |
| 1224 | Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 3 Year warranty |
| 1225 | Supplying and erecting integrated LED round burial light 6W IP65 & IK10 class having pressure die-cast housing, having system lumens output of Min. 500 Lumens, min. efficacy of 85 lumen/W, CRI>80, CCT upto 6500K, THD0.90, operating range of 100-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50, including driver, salt spray tested for 500 Hrs. including making of recess of appropriate size for flushing into surface with 2 Year warranty as per specification No FG-ODF/FLS2. |
| 1226 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC |
| 1227 | Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) |
| 1228 | Supplying & erecting Dewatering Monoblock pump set 415V, 3 phase, 50C/s, A.C. supply of 2.25KW/ 3 H.P., of 12 to 26 m head with 560 to 70 LPM discharge, 10.5mm Solid Handling Capacity,non clogging minimised abrasive wear, large impeller clearance & maintenance free pump set with water proof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation. specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP |
| 1229 | Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload elementwith necessary materials and connected to supply up to 7.5 H.P. |
| 1230 | Supplying and erecting pump protection relay comprising current sensing phase failure and UV+OV relay with dry run and overload protection suitable for 3 phase pumps. |
| 1231 | Supplying & erecting Water level controller 230/415 V, A.C. , Two way under ground tank operation only. |
| 1232 | Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only. |
| 1233 | Supplying & erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos) |
| 1234 | Supplying and erecting non return valve 25 mm dia in position made of gun metal complete. |
| 1235 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 1236 | Supplying and erecting non return valve 65 mm dia in position made of gun metal complete. |
| 1237 | Providing & Fixing 40mm dia. Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required.All work Complete as per direction of the Engineer-in-Charge. (R.A CPWD Electrical -2018,16.7.4.8) |
| 1238 | Providing & Fixing 50mm dia. Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required.All work Complete as per direction of the Engineer-in-Charge. (R.A CPWD Electrical -2018,16.7.4.7) |
| 1239 | Providing & Fixing 65mm dia. Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required.All work Complete as per direction of the Engineer-in-Charge. (R.A CPWD Electrical -2018,16.7.4.6) |
| 1240 | Supplying, fixing, testing and commissioning of following sizes 65mm dia Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. (R.A CPWD Electrical -2018, 16.11.3.9) |
| 1241 | Supplying, fixing, testing and commissioning of following sizes 50mm dia Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. (R.A CPWD Electrical -2018, 16.11.3.10) |
| 1242 | Supply, installation, testing and commissioning of Skid mounted Hydro-pneumatic system of Vertical in line pump set with Variable Frequency Drive . Domestic Water Supply System For Building -150 lpm, Head - 60 meter (Approx. 4.5hp /pump)Pump Qty - 3 (2 working +1 stand by / Duty Assist) Siemens switch gear make control panel along withPLC,PID Controller withall necessary cascade system automation, Power & Control MCB, MPCB , Over load \ Under load, SPP \ RPP, Dry run and all necessary pump & voltage protection, Indication lamp,Digital Pressure indicator cum controller.Danfoss make Pressure Transmitter & Pressure switch, Gauge, Pressure Tank etc. Skid for pumpset with Hot deep GalvnisedSuction & Delivery Header Plumbing Accessories along with Ball Valve, NRV, Y type StrainerPolycab make power cable for pumpset & Control cablefloat switch sensor , control cable for sensoretc complete as per direction of Engineer-in-charge. Pumpset & Control Pannel shall be company assembled factory fitted system with test certificate should be submitted. Vendor to submit performance curves and technical catalog of the proposed model for review & approval by consultants. |
| 1243 | Supply, installation, testing and commissioning of Skid mounted Hydro-pneumatic Drinking Water Supply SystemFor Building - (Location - Pump Room)Capacity per pump - 125 lpm, Head - 60 meter (Approx. 3.7hp /pump)Pump Qty - 2 (1 working+1 stand by / Duty Assist)Siemens switch gear make control panel along withPLC,PID Controller withall necessary cascade system automation, Power & Control MCB, MPCB , Over load \ Under load, SPP \ RPP, Dry run and all necessary pump & voltage protection, Indication lamp,Digital Pressure indicator cum controller.Danfoss make Pressure Transmitter & Pressure switch, Gauge, Pressure Tank etc. Skid for pumpset with Hot deep GalvnisedSuction & Delivery Header Plumbing Accessories along with Ball Valve, NRV, Y type StrainerPolycab make power cable for pumpset & Control cablefloat switch sensor , control cable for sensoretc complete as per direction of Engineer-in-charge. Pumpset & Control Pannel shall be company assembled factory fitted system with test certificate should be submitted. Vendor to submit performance curves and technical catalog of the proposed model for review & approval by consultants. |
| 1244 | Supply, installation, testing and commissioning of Skid mounted Hydro-pneumatic Flushing Water Supply SystemFor Building - (Location - Pump Room)125 lpm, Head - 60 meter (Approx. 3.7hp /pump)Pump Qty - 3 (2 working+1 stand by / Duty Assist)Siemens switch gear make control panel along withPLC,PID Controller withall necessary cascade system automation, Power & Control MCB, MPCB , Over load \ Under load, SPP \ RPP, Dry run and all necessary pump & voltage protection, Indication lamp,Digital Pressure indicator cum controller.Danfoss make Pressure Transmitter & Pressure switch, Gauge, Pressure Tank etc. Skid for pumpset with Hot deep GalvnisedSuction & Delivery Header Plumbing Accessories along with Ball Valve, NRV, Y type StrainerPolycab make power cable for pumpset & Control cablefloat switch sensor , control cable for sensoretc complete as per direction of Engineer-in-charge. Pumpset & Control Pannel shall be company assembled factory fitted system with test certificate should be submitted. Vendor to submit performance curves and technical catalog of the proposed model for review & approval by consultants. |
| 1245 | Sub Work No. 2 :- Name of work:- Estimate No115650 /23-24Providing Lifts to Proposed Construction of Chhatrapati Shahu Maharaj Research, Training & Human Development Institute (SARTHI) Sub centre at ITI Campus, Aundh, PuneSITC of Electric Traction Passenger Liftwith · Rated capacity :- 10 Passenger/680Kg· Floors :-G+12 floor (13 Stops/13 Landings) · Travel :- 44 mtrs · Location of Lift Machine:- MR/MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of 1300 mm wide x 1350 mm deep x 2250mm high· Lift shaft available having clear size of 2000mm wide x 2000mm deep, pit depth-1500mm, Overhead height -4500mm· Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory)Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge..COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.Clear Car size of 1300 mm widex 1100 mm deep x 2000 mmm high.LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20\" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.A1 -For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP\"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. |
| 1246 | SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680Kg· Floors :-G+2 floor (3 Stops/3 Landings) · Travel :-11.4 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 900 mm wide x 2000 mm high· Clear Car size of 1300 mm wide x1350 mm deep x 2250mm highLift shaft available having clear size of2000mm wide x 2000mm deep, pith depth-1500mm, Over height-4500mm· Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landingsLift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters.The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.A -For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP\"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. |
| 1247 | SITC of Electric Traction Passenger Liftwith · Rated capacity :- 8 Passenger/544Kg· Floors :-G+2 floor (3 Stops/3 Landings) · Travel :-11.4 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0 mps VS· Car/Landing doorclear opening of 800 mm wide x 2000 mm high· Clear Carsize of.1300 mm wide x1100.mm deep x2250mm high · Lift shaft available having clear size of 1900mm wide x 1900mm deep,lift pit depth 1500mm, over height-4500mm· Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor..· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters.The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.A-For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP\"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. |
| 1248 | SITC of Triplex Lift control system for three nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. |
| 1249 | SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. |
| 1250 | Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1251 | Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1252 | Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 1253 | Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 1254 | Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 1255 | Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete. |
| 1256 | Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 1257 | Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 1258 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected. |
| 1259 | Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 1260 | Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW |
| 1261 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW |
| 1262 | Point wiring (1.7.19)Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW |
| 1263 | Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 1264 | Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17Wwith high transitivity diffuser withsystem lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%,p.f. >0.95, operating range of120-270V, surge protection of 4 kV, Life class of50,000 Hrs. at L70B50, includingdriver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 1265 | Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. |
| 1266 | Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC |
| 1267 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 1268 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 1269 | Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1270 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1271 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivitywithearth leakage trip indicationcomplete as per specification no. SW-RCCB/RCCB |
| 1272 | Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 1273 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication completeas per specification no. SW-RCCB/RCCB |
| 1274 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 1275 | Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 1276 | Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core4sq mm copper conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1277 | Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 1278 | Supplying & erecting G.I. pipe‘A’ class 40 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE |
| 1279 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 1280 | Supplying and erecting annealed bare copper wireof high purity of required sizesused forearthing onwall with necessarycopperclampsfixedon wall/cable/conduitwithscrews complete. |
| 1281 | Sub Work No. 3 :- Name of work:- Estimate No 115650/23-24 . Providing Street Lights to Proposed Construction of Chhatrapati Shahu Maharaj Research, Training & Human Development Institute (SARTHI) Sub centre at ITI Campus, Aundh, PuneProviding & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 1282 | Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness65 micron, made from high tensile structure grade steel as per BSEN - 10025 S355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm.flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/HM (excluding luminaries) |
| 1283 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 1284 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 1285 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation. |
| 1286 | Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete. |
| 1287 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). |
| 1288 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multistra nded copper Industrial cable for voltage grade up to 1.1 kV ( 32 Polesx 7 mtr = 2245 m ) ( 2 Highmast 14 mtr x 12 = 168 Total --392 ) |
| 1289 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 1290 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 1291 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 1292 | Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 1293 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 1294 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 1295 | Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1296 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 1297 | Sub-Work No. 4:- ESTIMATE NO :-115650/2023-24 Providing Fire fighting system, for proposedProposed Construction of Chhatrapati Shahu Maharaj Research, Training & Human Development Institute (SARTHI) Sub centre at ITI Campus, Aundh, PuneSupplying, installation, testing and commissioning ofMain fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual / automatic operation and consisting of following(a)Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b)Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation onwith IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c)M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d)Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 1298 | Supplying, installation, testing and commissioning ofjockey fire pump (JP)suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b)Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operationwith IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, asper specification no. FF-MFP/JP |
| 1299 | Supplying, installation, testing and commissioning ofbooster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operationwith IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevellingcomplete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP |
| 1300 | Supplying, installation, testing and commissioning ofmain fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speedsuitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 1301 | Supplying, erecting, testing & commissioning offire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessorieswith following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump (MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU\"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handlewith HRC fuses of suitable rating. Add onFor addition of capacity of main electric motor driven fire pump MFP (1 working) for hydrant system is more than 22kW, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears and motor starters for main & jockey pumps along with necessary accessoriesfor main & jockey fire pumps MFP (1working), JP (1working + 1standby, alternate run per start in auto mode)For main electric motor driven fire hydrant system pump of 55kW capacity & relevant capacity jockey pump add Rs….For addition of fire sprinkler system to basic fire hydrant system control panel(FCP) which includes one main electric motor driven firepump MFP (1working) having __kW capacity& relevant capacity jockey pumps, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgearsbusbar and additional motor starters for main & jockey pumps along with necessary accessories with software & hardware for main & jockey fire pumps additional Sprinkler system MFP (1working) @22kW, JP (1working + 1standby, alternate run per start in auto mode) @relevant capacityFor main electric motor driven fire sprinkler system pump of 55kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode,add Rs….For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode)& jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs.......The control for diesel engine comprises ofautomatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps.For addition of two numbers of booster pump for fire hydrant/sprinkler, add as follows in the basic cost of item no 13-5-1 towards necessary accessories, indicators etc. with necessary interlocking and updation of control logic, add Rs.......for 5.5/ 7.5 kW centrifugal type booster pump 1no (1working), add Rs….... |
| 1302 | Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload elementwith necessary materials and connected to supply up to 7.5 H.P. |
| 1303 | Supplying and erectingG.I. pipe‘C’ class ERW25 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1304 | Supplying and erectingG.I. pipe‘C’ class ERW50 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1305 | Supplying and erectingG.I. pipe‘C’ class ERW65 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1306 | Supplying and erectingG.I. pipe‘C’ class ERW75/80 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1307 | Supplying and erectingG.I. pipe‘C’ class ERW100 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1308 | Supplying and erectingG.I. pipe‘C’ class ERW150 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1309 | Supplying and erectingG.I. pipe‘C’ class ERW200 mm dia with necessary fittings complete asper specification no. FF-PP |
| 1310 | Providing coating of bitumen paint &4mm thick wrappingfor underground 100 mm ring main of fire fighting system. |
| 1311 | Providing coating of bitumen paint &4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 1312 | Providing coating of bitumen paint &4mm thick wrapping for underground 200 mm ring main of fire fighting system. |
| 1313 | Excavating hard murum / stone metal roadby chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete. |
| 1314 | Supplying anderecting75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen,end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS |
| 1315 | Supplying anderecting150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SSscreen,end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS |
| 1316 | Supplying anderecting200 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, forpositive suction complete asper specification no. FF-VL/ELS |
| 1317 | Supplyinganderecting75/80mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 1318 | Supplyinganderecting100mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 1319 | Supplyinganderecting150mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 1320 | Supplyinganderecting200mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 1321 | Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1322 | Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1323 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1324 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1325 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1326 | Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 1327 | Supplying and erecting 75/80 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1328 | Supplying and erecting 150 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1329 | Supplying and erecting75/80 mm dia cast iron double flange ball type NRVcomplete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1330 | Supplying and erecting100 mm dia cast iron double flange ball type NRVcomplete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1331 | Supplying and erecting150 mm dia cast iron double flange ball type NRVcomplete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1332 | Supplying and erecting200 mm dia cast iron double flange ball type NRVcomplete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 1333 | Supplying and erecting20 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV |
| 1334 | Supplying and erecting25 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV |
| 1335 | Supplying and erecting50 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV |
| 1336 | Supplying anderectingstainless steel single outlethydrantvalve fitted with necessary accessories complete asper specification no. FF-VL/HV |
| 1337 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose)along with necessary accessories complete asper specification no. FF-FFA/HV |
| 1338 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m inlength, fitted with necessary accessories complete asper specification no. FF-FFA/RRL |
| 1339 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specifications no. FF-FFA/NZ |
| 1340 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete asper specification no. FF-FA/FBC |
| 1341 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete asper specification no. FF-FA/FMC |
| 1342 | Supplying and erecting300 mm dia 1.5min heightair vessel / tankfabricated from min 5mm thick M.S. sheet complete asper specification no. FF-FFA/ACT |
| 1343 | Supplying anderecting20/25mm dia gun metal air release cock, with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete asper specification no. FF-FFA/ARV |
| 1344 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete asper specification no. FF-FFA/PG |
| 1345 | Supplying and erecting12/15 mm dia pressureswitchwith provided isolationvalve,G.I. nipple, elbow, etc complete asper specification no. FF-FFA/PS |
| 1346 | Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer diawith required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP |
| 1347 | Supplying and erecting M.S./CRCA cabinet forhousingFireBrigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet andangleiron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\" x 6\") andlocking arrangement with necessaryfixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 1348 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. |
| 1349 | Supplying, erecting, testing and commissioning vane type water flow detector75/80 mm dia. with1)Visual switch activation, 2)Rugged switch assembly, 3)Heavy duty aluminium pipe saddles, 4)Durable metal enclosure, 5)Steel U bolts for secure mounting, 6)Two SPDT (Single pole double track) synchronised switches, 7)serviceable without draining pipes. |
| 1350 | Supplying, erecting, testing and commissioning vane type water flow detector100 mm dia. with1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 1351 | Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM. |
| 1352 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 1353 | Supplying, installation, testing & commissioning of Sprinkler Flexible Pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar. The hose assembly includes 1200 mm long, 28 mm diameter corrugated stainless steel flexible hose with a braided stainless steel exterior.complete all the work up to the satisfaction of the Engineer in charge. |
| 1354 | Supplying, installing, testing, and commissioning standard response Pendent / Upright type sprinkler (Standard coverage) quartzite bulb type with 15mm screwed end connection of 68 deg. C.tempersture rating K-80 and orifice shall not be less than 6mm sprinklers shall be UL listed approved with chrome finished.complete all the work up to the satisfaction of the Engineer in charge. |
| 1355 | Supplying, installing, testing, and commissioning standard response Sidewall sprinkler (Standard coverage) quartzite bulb type with 15mm screwed end connection of 68 deg. C.tempersture rating K-80 and orifice shall not be less than 6mm sprinklers shall be UL listed approved with chrome finished.complete all the work up to the satisfaction of the Engineer in charge. |
| 1356 | Providing and fixing 150 mm dia installation valve with Hydraulic trim type automatic alarm to be connected with controlvalvedrainand test valveasper manufacturer\"srecommendations . with accessories like water motor gong bell, Test & drain valve , Flow switch etc UL listed etc complete to satisfaction of Architect/ PM |
| 1357 | Supplying, installing, testing, and commissioning of portable fire extinguishers of ABC dry powder stored pressure type fire extinguishers of 6 Kgs.capacity Complete with standard discharge valve with tube, CI bracket for wall mounting etc. complete as per confirming to IS : 15683 complete all the work up to the satisfaction of the Engineer in charge. |
| 1358 | Providing and fixing in position statutory Signage\"s made out of 3mm thick opaque PVC foam board, machine cut, non reflective, auto glow (type & Make), with silicon adhesive for safe evacuation of occupants in case of emergency. Sign indicators should be provided at prominent places as per Fire Provisional NOC (As per - IS-9457, IS-12349, IS-12407). complete all the work up to the satisfaction of the Engineer in charge. |
| 1359 | Providing, laying, testing & commissioning of 80mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge. |
| 1360 | Providing, laying, testing & commissioning of 150mm dia resilient rubber neoprene lined single arch Vibration eliminators (Expansion bellows) suitable for Design Pressure 16 kg/sq cm and test pressure 24 kg/sq cm. complete all the work up to the satisfaction of the Engineer in charge. |
| 1361 | Providing and fixing 25 mm dia Inspection & Testing Assembly with 25mm gunmetal ball valve, gun metal sight glass bypass valve & connected to drain line etc complete as per drawing. |
| 1362 | Supplying, erecting testing and commissioning beam smoke detector four wire single ended reflected type with 8 \" receiver having digital display for easy alignment, adjustable sensitivity & heater kit for transmitter/receiver and reflector with necessary connections on suitable back box. The protection range of beam detector is 5 to 70 m. |
| 1363 | Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI |
| 1364 | Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 1365 | Supplying, installing, testing and commissioning of micro processor basedintelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 1366 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 1367 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP |
| 1368 | Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD . |
| 1369 | Supplying, installing, testing and commissioning of intelligent addressable thermal / heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area\"s etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 1370 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. |
| 1371 | Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM |
| 1372 | Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM |
| 1373 | Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM |
| 1374 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 1375 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. withPVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 1376 | Supplying and fixing 17U floor mount rack (Dimension-DxWxH – 800x600x954mm) as per specification No. WG-NAS/RAK |
| 1377 | Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wirecomplete. |
| 1378 | Supply, installation, testing & commissioning of 6 Watt Cone type Ceiling Mounted metal grill Speakers with line matching transformer, Power tapping: 1.5W/3W/6W, Frequency response: 100-20000 Hz. SPL (1W 1m) 92 dB, including screw clamp mounting with required accessories. (Colour - White) |
| 1379 | Supply, Installation, testing and commissioning of 6 Watt Box type Wall / Surface Mount Speaker with line matching transformer, Power tapping: 1.5W/3W/6W, ABS or metal body, Frequency response: 100-20000 Hz. SPL (1W 1m) 92 dB, including required mounting accessories. |
| 1380 | Supply, Installation, testing and commissioning of 10 Watt column/wall mount Projector Speaker (uni directional) with line matching transformer, Power tapping: 5W/10W, fire protected ABS or Metal cabinet, includes a steel U-bracket, with adjustable inclination and easy installation with required accessories. |
| 1381 | Supply, installation, testing & commissioning of 6 Zone Voice Alarm PA Controller with built in audio message generator (multi message), 6 Zone 70/100V live outputs for Speaker circuit, Fireman Microphone, Pre-recorded evacuation messages, Should be able to send 2 different pre-recorded messages simultaneously (message should be in 2 languages English & Hindi), Phased evacuation, 6 supervised input contact relays for integration with Fire Alarm Control Panel, Up to 6 call stations can be connected together with controller. The controller should integrates multiple functions such as audio storage, playback, zone control, audio monitoring, scheduled broadcast and fault diagnosis, audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover etc. complete with cords, connectors & required accessories. |
| 1382 | Supply, installation, testing & commissioning of 480 Watt, high efficiency Power amplifier, 70/100V loudspeaker output voltages, RMS output power limiter, high temperature, DC, short circuit, mains undervoltage protection, DC supply undervoltage protection, inrush current limiter with cords, connectors, power supply & required accessories. |
| 1383 | Supply, installation, testing & commissioning of 240 Watt, high efficiency Power amplifier, 70/100V loudspeaker output voltages, RMS output power limiter, high temperature, DC, short circuit, mains undervoltage protection, DC supply undervoltage protection, inrush current limiter with cords, connectors, power supply & required accessories. |
| 1384 | Supply, installation, testing & commissioning of 6 Zone Call Station (Microphone) with built in numerical keypad, gooseneck microphone, zone selection keypad & having LED indication for zone selection, fault and emergency state with required cable, cords & accessories. |
| 1385 | Supply, installation, testing & commissioning of Audio Music Player with built in USB port, SD card, support MP3 & other audio formats, complete with cable, cords & required accessories. |
| 1386 | Sub Work No. 5:- Estimate No115650 /2023-24 Providing HVAC System at newly constructed of Chhatrapati Shahu Maharaj Research, Training & Human Development Institute (SARTHI) Sub centre at ITI Campus, Aundh, PuneSupplying, installing, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2.0 TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50Hzs, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete with Refrigerants R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer ferr operation & temperature display on indoor unit, noise level max. 50dBA at position ( IDU & ODU mounting stands) as per specification no. APAC/ WAC (3 For Server Room) |
| 1387 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS complient suitable for refrigerant system having 22SWG thickness and inner dia / size 16 mm complete. (Copper Piping For Above) |
| 1388 | Supplying, erecting, testing and commissioning of 14HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100%capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oilseparator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. (4 No.s For Multipurpose hall 2 AHUs1 No. for retirementroom, VC, JT MD1 for dir.cabin, officer cabin) |
| 1389 | Supplying, erecting, testing and commissioning of 22HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEMstandards working on HFC refrigerant R410A or other required/suitablegreen equivalent refrigerant, for minimum cooling capacity as delivering 100%capacity at 47° C, non stop cooling even at 56° C and coefficient of performance(COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/ digitalVRF/VRV technology microprocessor based control compressor starter/controlpanel with scroll compressor, air cooled copper condenser coil of suitable shapefor increasing maximum heat transfer area, rain protection cover, built in oilseparator, accumulator and oil receiver, copper tube aluminium fin air cooledcondenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phasepower supply (all suitable for high ambient conditions), internal copper refrigerantpiping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete. |
| 1390 | Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type room / indoor unit (IDU) of nominal capacity 1.8TR (594 cfm) to 2.2TR (655cfm) having EER asper BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, inbuilt drain pump, expansion device, cordless remote control with necessary controls with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting.The indoor unit shall also have an electronic control console. The unit shall be suitable for wall mounting and provided with suitable mounting brackets with any additional refrigerant and oil charge as per requirement during installation complete. ( 4 For Ante Chamber) |
| 1391 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz,AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 1 No.s JT D5 No.s conf 3 No.s director cabin1 No.s officer cabin |
| 1392 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 way cassetteroom / indoor unit (IDU- compact / standard size) of nominal capacity 4.1TR (1218 cfm) to 5.0TR (1624cfm) having EER asper BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant piping, cordless remote control and fresh air post etc. IDU shall have anti-corrosive coating suitable for coastal area in all respetcs suitable to operate on 1-phase, 230V, 50Hz, AC supply complete.The unit consisting with any additional refrigerant and oil charge as per requirement during installation complete. ( 1 For Retrirement Room & 2 for VC) |
| 1393 | Supply, installation, testing and commissioning of VRF/VRV based ceilingsuspended 2 way cassette room/indoor unit (IDU-compact / standardsize) of nominal cooling capacity 2.8TR (1130 cfm) to 3.7TR ( 1377 cfm )having EER as per BEE standards and specifications, suitable as per siterequirement with swing louvers and adjustable blades from sides. IDU withdrainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. ( 2 For Lounge & 2 For Cafe) |
| 1394 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 way cassette room/indoor unit (IDU-compact / standardsize) of nominal cooling capacity 1.0TR ( 441 cfm ) to 1.3TR ( 512 cfm ) having EER as per BEE standards and specifications, suitable as per siterequirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oilcharge as per requirement during installation. ( 3 For Dire Cabin) |
| 1395 | Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager controls minimum 16 systems of64 ODU\"s can be controlled and up to 992 IDU\"s can be individually mounted and controlled indoor units, having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitations, history function complete erected on wall integrated with provided fire alarm system. |
| 1396 | Supply, fabrication, installation andtesting of flexible canvas connections constructed between ductable unit / dampers / ducting of suitable size with fire resist flexible double canvas sleeve complete. |
| 1397 | Providing and applying of adhesive thermal insulation for supply return air duct with 19mm nitril rubber insulation having R-value as per the prevailing provisions in ECBE-2017. (Internal Duct Insulation) |
| 1398 | Providing and applying of acoustic insulation for air duct with 25mm thick, 48kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheeets complete. (For the main duct connections to AHUs) |
| 1399 | Supplying and installatiing of collar damper of GI material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size. (Duct damplers) |
| 1400 | Supplying and installatiing of high pressure grade required size copper connection Y or T - joints / refnet complete erected on wall/ ceiling with supports/raceways, nitrile rubber insulation, painting, etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditing system, (Fore Indoor Unit Piping Connections) |
| 1401 | Supplying and erecting aluminium powder coated linear grill of suitable size for width length without coller dampers having matching colour with the existing false ceiling and suitable for deflection of 15?/30?/45?, (150mm height)Grilles for return air - multipurpose hall |
| 1402 | Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEMstandards of VRV / VRF air conditioning system complete. (Copper Piping for 22HP and 14 HP unit ) |
| 1403 | Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEMstandards of VRV / VRF air conditioning system complete. (Copper Piping for 22HP and 14 HP unit ) |
| 1404 | Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEMstandards of VRV / VRF air conditioning system complete. (Copper Piping for Indoor unit |
| 1405 | Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEMstandards of VRV / VRF air conditioning system complete. |
| 1406 | Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEMstandards of VRV / VRF air conditioning system complete. |
| 1407 | Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5mm dia. (OD) for liquid line / suction line of suitable gauge ( hard pipe for liquid main line and soft copper pipe for refrigerant along with necessary supports, hanger,s clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damage,s fungal growth, flame spread, water permeance and ultraviolet radiations with OEMstandards of VRV / VRF air conditioning system complete. |
| 1408 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. (Copper Piping for Indoor Units) |
| 1409 | Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. ( Ducting=22G ) (multipurpose hall and toilet ventilation ducting ) |
| 1410 | Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetin (Ducting=24G ) (multipurpose hall AHU and Main ducting) |
| 1411 | Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BWMultipurpose Hall AHU |
| 1412 | Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. Multipurpose Hall AHU |
| 1413 | Supply, Installation, Testing & Commissioning of outdoor type floor mounted Double skin AHU comprising of 48 mm thick panel filled with PUF, DIDW backward curved / airfoil fan with 2 ply fire retardant canvas at the outlet ,complete with suitable motor and mounting arrangements on common rail anti vibration mount, thermal break profile, Return air mixing chamber with fresh air and return air aluminum dampers,DX type Cooling Coil - 2 circuits with capillery header / Electronic Expansion Valve to be connected with VRF/VRV ODU system, SS insulated drain pan, Inlet Filter EU-5, doors with proximity switch for inspection lamp and AHU stop, including volume control damper and motorized fire damper with fire test control panel at AHU outlet installed, PLC based Control logic Panel with possibilty of third party BMS connectivity for remote operation, etc. The AHU shall have starter panel interconnected with fire panel for fire mode operationCapacity = 10500CFM / 50mmWg / 21.7TR (Multipurpose Hall AHU) |
| 1414 | Supply, installation, testing and commissioning of Vane Axial Smoke Exhaust Fans with Sound Attenuators, complete with drive and Supports system with vibration isolators. Fire rated H Class motor, 300 deg.C at 2 Hr. Motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase AC supply and shall have high efficiency motors, with all supporting structures and accessories, waether proof external exhaust louvers. Sound level shall not be more than 55 dBA from 3 m AMCA Certified only. For multipurpose hall Smoke Exhaust Capacity = 8300CFM / 20mmWg |
| 1415 | Supplying, erecting, testing & commissioning exhaust air system, ductable circular inline exhaust air fan inlet unit having 500 cfm capacity with maintaining the static pressure minimum 30mm suitable to operate on 1ph, 230 V, 50Hz, A.C. supply complete. toilet Exhaust |
| 1416 | Sub Work No. 6 :- Name of work:- 115650 /23-24 Providing CCTV and Networking system, for proposedProposed Construction of Chhatrapati Shahu Maharaj Research, Training & Human Development Institute (SARTHI) Sub centre at ITI Campus, Aundh, PuneSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 1417 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit |
| 1418 | Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX . |
| 1419 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 1420 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connectionscomplete. |
| 1421 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 1422 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 1423 | Supplying & erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 1424 | Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 1425 | Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 1426 | Supplying & erecting 100 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 1427 | Supplying & erecting 0.5 mm dia, copper jumper wire as per specification No. WG-TW |
| 1428 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW |
| 1429 | Supplying and erecting 5m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1430 | Supplying and erecting 10m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1431 | Supplying and erecting 15m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1432 | Supplying and erecting 20m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1433 | Supplying and erecting 25m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 1434 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 1435 | Supplying, erecting & commissioning MDF Box 150x150 pairs made frommin. 1.5mm thick MS sheet as per specification no. WG-TW |
| 1436 | Supplying, erecting & commissioning MDF Box 500x500 pairs made frommin. 1.5mm thick MS sheet as per specification no. WG-TW |
| 1437 | Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 1438 | Supplying, erecting & commissioning 10 pair module for connection &disconnection of telephone cable as per specification no. WG-TW |
| 1439 | Supplying, installing, testing & commissioning IP EPABX for 10 extensions complete. |
| 1440 | Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as perspecification complete. |
| 1441 | Supplying, installing, testing & commissioning IP telephone instrument as per specification complete. |
| 1442 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 1443 | Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC |
| 1444 | Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH |
| 1445 | Supplying and erecting LSZH armoured multimode optical fibre cable with 12 fibres, core dia 50/125 µm (OM3), suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC |
| 1446 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 1447 | Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC |
| 1448 | Supplying and plugging 3 m fibre patch cord LC-SC MM (50) OM3 LSZH duplex complete as per specification no. WG-COC/FPC |
| 1449 | Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch,10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete. |
| 1450 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernetmanaged switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/GBS |
| 1451 | Supplying, fixing, and configuring 20 (1G-RJ45) ports + 4 combo 1G ports + 4 10G (SFP+) ports, Layer 3 switch, SI Image, 6KV surge protection on ethernet port and console port for management erected in provided rack complete. |
| 1452 | Supplying, fixing, and configuring 24 ports + (4 SFP+) POE switch, 370W, 6KV surge protection on ethernet port and console port for management on provided rack as per specification No. WG-NWC/ENS |
| 1453 | Supplying, fixing, and configuring 10G Base -SR (SFP+) simplex MMtransceiver erected in provided rack complete. |
| 1454 | Supplying, fixing, and configuring modularised multi-service router802.11/a/n/ac unified Wave 2.5 GHz, with RJ-45 port, supporting 1 to 13channels for 2.4 GHz, with unified wireless access point complete. |
| 1455 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 1456 | Supplying and fixing Tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 1457 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 1458 | Supplying and fixing 12 ports light guide unloaded interconnect unit,rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIU |
| 1459 | Supplying and fixing SC/LC type multimode pigtails (OM3) for LIU toterminate OFC in LIU as per specification No. WG-NAS/LIU2 |
| 1460 | Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK |
| 1461 | Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAK |
| 1462 | Supplying and fixing 22 U floor mount rack (Dimension-DxWxH – 800x600x1176 mm) as per specification No. WG-NAS/RAK |
| 1463 | Supplying and fixing 42U floor mount server rack (Dimension-DxWxH –800x600x1866 mm) as per specification No. WG-NAS/RAK |
| 1464 | Supplying and fixing 9U IP66 outdoor mount server rack with pole mountbracket (Dimension- DxWxH - 500x600x450 mm) as per specification No. WGNAS/RAK |
| 1465 | Supplying and fixing dual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrent access point with POE in networking as per specification no. WG-NAS/LAP2 |
| 1466 | Supplying, installing and activating physical license pack software for multiple access point with management, configuration and trouble shooting for all access point in network complete. |
| 1467 | Supplying and fixing 2 m Telephone patch cord of RJ11 type |
| 1468 | Supplying and installing, testing & commissioning of Digital (Hybrid) type EPABX of 10 Digital + 450 analog extensions, built in Compatible Software Server, USB Ports, internal Storage upto 64GB, Group Conference facility. Voice Messages, ethernet ports, Universal Slots for Interface expansion Cards, Single Line Analog Telephones port, Trunk line, BRI ports, GSM/3GPorts, SIP Trunks port complete with required accessories. (Make- Matrix / Panasonic / Alcatel or equivalent) |
| 1469 | Supply, installation, testing & commissioning of Ceiling Mounted Smart LED Projector- Full HD, 1920 x 1080 Resolution, 3800 ANSI Lumens white/color output, Varifocal lens, 16 watt audio output, 10000:1 contrast ratio, Built-in wireless and miracast, HDMI 2 inputs, VGA, 6000 hours unwoven filter, 12000 hours lamp life, HDCR/Accentualizer, RJ-45 port, including Remote control, power cord, cable, lens cover & required accessories with Ceiling mounted brackets. |
| 1470 | Supply & fixing of 150\" Diagonal Motorized white Screen for projector with motor, fixing brackets & required accessories. |
| 1471 | Supply, installation, testing & commissioning of Smart TV, Wall mount 55\" Ultra HD Flat LED TV having minimum 2 HDMI, 2 USB & 1 RJ 45 port, AV port with inbuilt Wi-Fi including wall mount accessories. |
| 1472 | Supplying& erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. |
| 1473 | Supply of 64 Channel professinal series 4K HD Network Video Recorder Smart H265+/H265/Smart H264+ Max 320Mbps Incoming Bandwith upto 12MPResolution for Preview and Playback. Bit Rate 16Kbps-20Mbps per channel. 2HDMI/ 2VGA simultaneous video output to enhance the storagereliablity when the network break down, Quad- Core embeded processor. 8 STATA III Ports upto 6 TB for each HDD for 2 RJ45 port (10/100/1000Mbps) independant of joint Networking. Analytical Features like - ANPR, People Count, Face Detection, Missing/ Abonded Objects, Tripwire and Instrsion alarms, Smart FAN to achive high cooling effects. Automatic Network Replenishment (ANR) Technology - Network Video Recorders with ANR function automatically store video data on an IP camera SD card when the Network is disconnected. After recovery of the network, the NVR automatically retrives the video data stored on the camera. |
| 1474 | Supplying& erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S,maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB,MTBF 1000000 Hrs. HTTPS.RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 1475 | Supplying& erecting 43\" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 1476 | Sub Work No. 7 :- ESTIMATE NO :-1156530/2023-24 Providing solar water heating system and Heat pump at newly constructed of Chhatrapati Shahu Maharaj Research, Training & Human Development Institute (SARTHI) Sub centre at ITI Campus, Aundh, PuneSupplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. calculation attached |
| 1477 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).foundation size forstructure 0.3 x0.3x.15x 4nos=.054 for 1 system for 51 nos 500LPM x 0.054=27.54 + for for tank and heat pump tank requre approx 15.2 total=42.74=43cum, 43x3= 129 |
| 1478 | Supplying, installing, testingand commissioning of ETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I :2004 complete as per specification no. ESD-SHWS-ETC (50 no x 500=2500) |
| 1479 | Supplying and erecting 20/25 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 2.6 mm conforming to IS 15778 (CTS Series)with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC |
| 1480 | Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC),thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC |
| 1481 | Supplying and erectingelastomeric nitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system. |
| 1482 | Supplying and erectingelastomeric nitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 42 mm for solar water heater/AC system. |
| 1483 | Supplying and erecting ISI mark GI pipe 40 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 1484 | Supplying and erecting non return valve 40 mm dia in position made of gun metal complete. |
| 1485 | Supplying and erecting 40 mm. dia. gun metal sluice valve at position with necessary materials complete. |
| 1486 | Supplying, installing, testing and commissioning of Monoblock Heat pump, having dimension: 995 x 785 x 1700 (mm), Input power: 2.22 kW, 400 V, 3 Ph, 50 Hz, Output power: 8 kW having hot water temperature range 35°C to 75°C and ambient temperature range for max. efficiency 7°C to 43°C, with glass lining hot water tank of 455 ltr. and min. 220 Kg at rated pressure 10 bar with two emergency heating elements operated on three operational mode: Efficiency mode,Hybrid turbo mode and Standard mode with Adaptive Energy System (AES), LED display with necessary accessories complete with 5 years ON-SITE warranty. |
| 1487 | Supplying & erecting Pressure Booster Pump, single phase, 50C/s, A.C. supply of 0.75 KW/ 1 H.P., With discharge of 480 to 13 LPM for 10 to 50 Mtr Head &25 mm suction/ 25 mm delivery pipe,for Domestic Pressure boosting applications. |
| 1488 | Supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270 V and output voltage 200-250V rated for 5kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16A plug top with overload & short circuit protection complete . |
| 1489 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 1490 | Supplying, installation and testing and commissioning of storage type Mild Steel mixing water tank of capacity 3000 ltrs. tested to a pressure of 8 kg/cm2, insulated with 50 mm thick rock wool with wire mesh around and cladded with 26 SWG aluminium of dish end type with working pressure of 6 kg/cm2, fabricated with 6 mm thick MS plate and dished ends with 8 mm thick plates complete with man hole cover, inner side of the tank coated with FRP coating of 3 mm thickness withstand temperature of 90°C provided with collars of 2\" BSP forprovision toinstall6 numbers of electrical heating coils if required with thermal sensors for automatic operation and integrated into the electrical circuits of the circulation pumps and the heat pump with safety valve drain, inlet and outlet nozzle, pressure gauge with all necessary accessories complete. |
| 1491 | Providing and fixing high-density polyethylene(HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacityup to 20000 litres. |
| 1492 | Supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia). |