| 1 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in hard/dense soil. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil. |
| 3 | M & L for Cement concrete type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete. |
| 4 | M & L for reinforced cement concrete (design mix) M-25 (20 mm graded aggregates) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. |
| 5 | M & L for reinforced cement concrete (design mix) M-25 (20 mm graded aggregates) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 6 | M & L for reinforced cement concrete (design mix) M-25 (20 mm graded aggregates) in Columns, pillars, piers, posts and struts. |
| 7 | M & L for reinforced cement concrete (design mix) M-25 (20 mm graded aggregates) in Beams, cantilevers, bressummers, lintels over 1.5m span. |
| 8 | M & L for reinforced cement concrete (design mix) M-25 (20 mm graded aggregates) in Chajjas. |
| 9 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surface of concrete. |
| 10 | M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finishedsquare, rectangular or polygonal surfaces of concrete. |
| 11 | M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, bands, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams etc rough finished flat surface of concrete. |
| 12 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surface of concrete. |
| 13 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 14 | M & L for mild steel TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 15 | M & L for brick work with sub class \"B\" old size bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6. |
| 16 | M & L for 40 mm thick Cement Concrete 1:2:4, type B-0 (12.5 mm graded aggregate) mixing with liquidwater proofing compound as per manufacturer’s instructions as in damp proof course to horizontal or vertical surfaces including necessary form work. NOTE: - water proofing compound will be measured and paid separately. |
| 17 | M & L for rendering 12 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smoth without using extra cement. |
| 18 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface and finishing the surface even and smooth without using extra cement. |
| 19 | M&L for rendering 10mmthick in cement mortar 1:3 on fair faces of brick work or concrete surface of ceiling and finishing the surface even and smooth without using extra cement. |
| 20 | Supply onlyLiquid water proofing compound. |
| 21 | M & L for 2 mm thick of Birlawhite putty/JK white wall care putty in two coats on new plastered wall and ceiling surface and making the surface uniform & smooth complete. |
| 22 | M & L for preparing surfaces plastered or unplastered new surfaces of wall and applying three coats of white wash complete |
| 23 | M & L for preparing surfaces plastered or unplastered new surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 24 | M & L for preparing surfaces plastered or unplastered new suraces of wall and applying two coats of cement base paint over one coat of primer with alkali resistant priming paint complete. |
| 25 | M&L for sand filling under floors or in foundations including watering and consolidation. |
| 26 | M&L for spreading and levelling in layers n.exc 25cm thick includingwell ramming and watering. |
| 27 | M&L for broken stone or boulders hardcore of gauge n exc 63mm deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface. |
| 28 | M&L for 75mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) in sub bases of floorcomplete. |
| 29 | M & L for 25mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring including finishing cement concrete surface even and smooth without using extra cement. |
| 30 | M & L for machine cut Kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 complete. |
| 31 | M & L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete. |
| 32 | M & L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in sub bases andfinishing cement concrete surface even and smooth without using extra cement complete. |
| 33 | Returning, filling in, including speading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil. |
| 34 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point. |
| 35 | S & F Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete. |
| 36 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete. |
| 37 | S & F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane. |
| 38 | M & L for preparation of new or previously untreated surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel (ordinary tint) over one coat of red oxide primer complete. |
| 39 | M & L for providing water proofing treatment over cleaned roof surfaces with super thermo APP modified water froofing membrane comprssing of following for non-approachable roof:-(i) Removal of existing roof treatment and cleaning sweeping and washing and down with water to remove all dust etc from plastred roof surfaces/wall and filling of crack with sealing compound etc.(ii)Bitumen based primer conforming to IS 3384-1965 at 0.30 kg per sqm.(iii) One layer of super thermo APP modified water proofing membrane with non polyster reinforcement of Make (M/S STP texsa Ltd/hyperplus membrane of M/S IWL India Ltd. M/S STP and Tikki Tar Ltd ) 3mm thick and minimum weight @ 3.50 Kg/sqm laid with gas torch and fasted on roof surfaces with roller. The over laps shall be sealed by flame including vertical surfaces after cutting necessary grooving and making good with PCC gola 1:2:4 type B1 etc adhere to bitumen all as per manufacturer instructions.(iv)Applying two coat of aluminium paint @ 0.20 kg/sqm per coat over bitumen layers as per manufacturer instruction (application including side lap overlaps shall be provided not less than 10cm and jointed sealed with torch as per manufacturer instruction/specification. |
| 40 | M & L for machine pressed interlocking chequered tiles 300 x 300 x 30 mm thick with grey cement and pigment over 15 mm thick screed bed in cement mortar 1:4 complete. |
| 41 | M & L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete. |
| 42 | M & L for providing, cement concrete type B-1, 1:2:4 (20 mm graded aggregate) in copings including weathering, slightly rounded or chamfered angles and throating as directed. |
| 43 | M&L for point wiring with 1.5 Sq mmsingle corePVC insulated unsheathedcopper FRLS multi stranded conductor cable in andincludingConcealed PVC conduitof size 20/25mm ISImarked inclusive oftees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi strandedcopper conductor 1.5Sqmm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincludingcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- |
| 44 | (a) One light or fan point controlled by one switch. |
| 45 | (b) One 3 pin socket outlet 5 Amps on the same board with other switch. |
| 46 | (c) One 3 pin socket outlet 5 Amps on independent board. |
| 47 | All as per item No.1 here-in-before but 3/5 pin socket outlet point 15 Amps independent, with cables of size 2.5 Sq mm multistranded, PVC insulated unsheathed FRLS copper conductor cable, and 1.5 sq mm PVC insulated unseathed FRLS copper conductor cable as earth continuity conductor connected to common earth dolly all in separate PVC conduit medium grade not less than 20mm dia ISI marked including provn ofGI sunken box thickness notless than 1.12 mm & 3 mm thick laminated hylem sheet top cover of required size all as specified and directed. |
| 48 | S & F switch piano flush button single pole one way 5 Amp. |
| 49 | S & F ceiling rose surface bakelite 65x50mm 2 to 3 terminal |
| 50 | S & F lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings |
| 51 | S & F for socket outlet 2-in-1, 5 pin, 5 Amps flush type. |
| 52 | S & F switch socket combination2-in-1, 3 pin, 5/15 Amp flush typeuniversal. |
| 53 | S & F sheet metal enclosure distribution board SPN, 8 ways 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs all as specified and directed. |
| 54 | S & F MCB single pole and neutral, 240 volts, 63 Amps all as specified and as directed. |
| 55 | S & F MCB single pole, 240 volts, up to 40 Amps, all as specified and as directed. |
| 56 | M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 57 | S & F for LED street light fitting 35/36 Watt 230 V AC outdoor type with high ressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with pre wired and necessary mounting arrangements and provision of 2.5 Sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. |
| 58 | S & F wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed. |
| 59 | Supply, laying and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 16 Sqmm 4 core laid in trenches or under road complete all as specified and as directed. (Note: Excavation, sand and brick work will be measure & paid separately) |
| 60 | M&L for earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal andcommon salt in alternate layers and electrode connected to galvanized wire 4mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 25 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, CI Earthing Pit cover 300 x 300 mm with angle iron 20 x 20 mm, 3 mm thick complete all as specified. Note: (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth. |
| 61 | Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed. |
| 62 | Supply and laying for brick of common burnt clay, sub class \"B\" old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cales abutting each other complete. |