Tender For Construction Of G Plus 2 100 Bedded Barrack Block 2 At Sahebganj Police Line In The District Of Sahebganj, sahebganj-Jharkhand

Jharkhand Police Housing Corporation Limited has published Tender For Construction Of G Plus 2 100 Bedded Barrack Block 2 At Sahebganj Police Line In The District Of Sahebganj. Submission Date for this Tender is 03-02-2024. Barrack Tenders in sahebganj Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

41772632
Corrigendum : Tender For Construction Of G Plus 2 100 Bedded Barrack Block 2 At Sahebganj Police Line In The District Of Sahebganj
Open Tender
Indian
Jharkhand
sahebganj
03-02-2024

Tender Details

Construction Of G Plus 2 100 Bedded Barrack Block 2 At Sahebganj Police Line In The District Of Sahebganj

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Jan-2024 Date Corrigendum Date 03-02-2024

Key Value

Document Fees
INR 10000 /-
EMD
INR 352000.0 /-
Tender Value
INR 3.51 Crore /-

BOQ Items

Name of Work: Construction of G+2 100 Bedded Barrack (Block 2) at Sahebganj Police Line in the district of Sahebganj
Sl. No. Item Description
1Section I Building Work
2Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
3Extra for earth work in hard soil as per specification and direction of E/I.( vide classification of soil item B)
4Filling infoundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earthobtainedfrom excavation offoundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
5Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
6Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
8Providing designation 75A brick work inC.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) IN FOUNDATION
10Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
11Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
12Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
13Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) Plinth Band
14Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
15Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
16Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
17Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
18Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
19Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
20Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
21Reinforcedcementconcreteworkin beams,Slab,Lintel Band,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
22Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform in Lintel Band
23Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
24Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases
25Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
26Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
27Reinforcedcementconcreteworkin beams,Slab,lintel,etcsuspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
28Centering and shuttering including strutting, propping etc. and removal of form Shelves (Cast in situ)
29Exra for adddition Hight in centering, shuttering where ever required with adequate bracing, propping etc. , including cost of deshuttering and at all levels, over a height of 3.5 m, for every additional height of 1metre or part there of (plan area to be measured) Suspended floors, roofs, landing, beams and balconies (plan area to be measured)
30Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
31Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in CM (1:6) in super structure with approved quality of Clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials raking our joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
32Providing 12mm thickcement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
33Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I.
34Extra for brick work for each consecutive floor above first floorincluding watering and scaffolding, all complete as per direction of E/I.
35( a) For S.F.
36From 250 mm B/W in S/S item "C" &"D"
37Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
38( a) For S.F. Total RCC in 2nd Floor
39Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
40Providing reinforecment ( Round bars conforming to I.S 432 dia in mm ( I.S 2062 Gr.A ) to 6 &8 mm dia rods as per approved design and drawing excluding carriage of bars to work sitecutting bending and binding with annealed wire with cost of wire, removal or rust placing the rods in position all complete as per building specification and direction of E/I. (i) 6mm dia Gr. A ( Only Valid for SAIL & TATA Steel )
41Providing TMT steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of Rods (straight orin coils) to work site, cutting,bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position complete as per building specification and direction of E/I.
42Providing TMT Steelreinforcementof 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage ofM.S. Rods (straight or in coils) to work site, cutting bending and bindingwith annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specificationand direction of E/I
4310 mm dia (TMT Fe 500 (Only valid for SAIL & TATA Steel )
4412 mm dia (TMT Fe 500 (Only valid for SAIL & TATA Steel ) , 16 mm dia (TMT Fe 500 (Only valid for SAIL & TATA Steel )Providing TMT steel reinforcement of20 mm & 25mm dia, bars as per approved design and drawing excluding carriage ofM.S. Rods (straight or in coils) to work site, cutting bendingand binding with annealed wire with costof wire, removal of rust placing the rods in positionall complete as per building specification and direction of E/I.(TMT Fe 500 (Only valid for SAIL & TATA Steel )
45Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specification and direction of E/I.
46Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge:
47Supplying, fitting & fixing 30mm thick solid core type decorative Single leaf flush shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes allcomplete as per building specification and direction of E/I.
48Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
49Supplying , fitting and fixing collepsible gate of approved size & make properly febricated with vertical double channels 20 x 10 x 2 mm at 100 mm center & braced with M.S.flat diagonals 20 x 3 mm, with top & bottom rails of T - iron 40 x 40 x 6 mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage, hoisting & taxes all complete as per building specification and direction of E/I.
50Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron
51Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
52Supplying, fitting & fixing 35mm thick solid core type decorative Double leaf flush shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes allcomplete as per building specification and direction of E/I.
53Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-ChargeGranite work
54Providing and fixing wooden moulded beading to doorframes with iron screws, plugs and priming coat on unexposed surface etc. complete. 50X20 MM
55Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
56Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
57Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
58Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm sqm 1311.05
59Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble. Area of slab upto 0.50 sqm
60Providing and laying 15 mm - 23 mm thick kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime morter (1:1:1) (lime putty : surkhi: coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (iv) 550 x 550 mm size
61Extra for plaster work over exterior surface for each consecutivefloor above first floor including cost ofscaffolding etc. all complete as per direction of E/I.
62( a) For S.F.
63Making 6x6mm grooves in plaster surface over walls truly horizontal vertical as specifiedat regular intervals at all heights including cleaning finishing scaffoding and curing with all leads and lifts of water all complete as per building specification and direction of E/I.
64Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size)
65Providing& supplyingCico liquid / impermo water proofing compound in cement concrete or cement mortar @2% of cement quqntity by weight ( as specified)for water proofing, including all carraige and taxes .
66Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade pigment using white cement
67Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
68Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
69Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgroutedwithfinesand,includingnecessaryexcavation,levelling& dressing & finishing the top smooth.
70Providing 250 mm wide brick drain in cement mortar (1: 6) with av. 150 mm. clean depth and 150 mm apron including cost of earthwork involved with 75 mm, cement concrete (1: 4: 3) over one brick designation 75A, flat soling in proper grade and slope at the base, the drain duly plastered in C.M (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
71Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
72Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
73Providing two coat of Oil bond distemperof approved shade and make over a cement primerover new surfaceincluding preparing the plastered surface by rubbing smooth with pumic stone or fine sand papper ,applying putty where requiredscaffolding, washing the floor and taxes all complete as per building specification and direction of E/I.
74Finishing Wall with acrylic smooth exterior paint of required shade : 13:46:1 New work ( Two or more coat applied @1.67 lit./ 10 sq.m over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm)
75French spirit polishing : 13.68.1 Two or more coats on new works including a coat of wood filler
76Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly includingcost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.)
77Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I
78Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
79Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming toIS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
80Coupler 110 MM
81Single pushfit Coupler
82110 MM Single pushfit coupler
83Single tee with door
84110X110X110 MM
85Single tee without door
86110X110X110 MM
87Bend 87.5°
88110 MM Bend
89110 MM Shoe
90Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
91Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
92Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
93Fly Ash Brick
94Bricks
95Coarse sand
96Stone Chips
97Cement
98Steel
99Earth
100SectionIIWater Supply
101Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls
102(a) 15mm dia
103(b) 20mm dia
104(c) 25mm dia
105Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
106Supplying materials labour tools for fixings of gun matel full way valve of approved quality with all complete job.
107(a) 25 mm dia
108Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Jaquar/Hindware Make
10915 mm nominal bore
110Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
111Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia
112SANITARY WORK
113Supplying , fitting and fixingvitreous whiteglazed earthenware I.W.C. of Party Hindustan orany other I.S.S approved make with 100mm H.C.I. "P" trap 15 litres C.I. pull and let go flushingcisternof nmaesor other I.S.S equipalent make complete withallfittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass couplingandclamps G.I. chain andpull includingsupplyingandfixingapairofvitreour white glazed eaarthenwarefoot rest to be fixed infloor 15mm C.I. bodybrass spindlestop cockofweight notlessthan 50grms, 15mm P.V.C. connection pipe 450 mm longand the exposedpiep andcistern withtwo coatsof approved paint over a coat ofred oxideprimer etc.allcomplete as per building specification and direction of E/I. Jaquar/Hindware Make
114© 580mm long I.W.C. pan with 10 litres low leve P.V.C. Cistern. Hindware/Jaquar Make
115Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquitoproof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required Jaquar,Hindware Make E.W.C. pan with ISI marked white solid plastic seat and lid
116Providing and fixing wash basin with C.I. brackets, 15 mm C.P. Brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings andbrackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
117Providing and fixing PTMT Bottle Trap for Wash basin and sink Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
118Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
119Providing and fixing white vitreous china flat back half stall urinal of 580X380X350mm with white PVC automatic flushing cistern, parryware/Hindware with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass with waste fitting as per IS : 2566 P.V.C. trap with outlet grating and other couplings in C.P. brass including parenting of fitting and cutting and making good the walls and floors wherever required..
120Single half stall urinals with litre P.V.C. auotmatic flushing cistern
121Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
122(a) 110 mm dia
123(b) 75 mm dia
124Making holes in walls for laying H.C.I Pipes and restoring the same after pipe laying as per specification and direction of E/I.
125(a) 250 mm thick wall
126(b) RCC chajja
127Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms
128Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
129Supplying materials and labours for constructing inspection chamber of designation class 100B bricks size 750mm deep, 600x450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x450mm C.I . Cover with frame (weight not less than 39 Kg ) alongwith earth work in excavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I
130Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe .
131250 mm dia. R.C.C. pipe
132Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length
133Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming toIS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
134Coupler 75 MM
135Coupler 110 MM
136Single pushfit Coupler
13775 MM
138110 MM Single pushfit coupler
139Single tee with door
14075X75X75 MM
141110X110X110 MM
142Single tee without door
14375X75X75 MM
144110X110X110 MM
145Bend 87.5°
14675 MM Bend
147110 MM Bend
14875 MM
149110 MM Shoe
150Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board
151510x1040 mm bowl depth 225 mm
152Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
153150 mm diameter
154Section - III Septic tank & Soak pit
155Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
156Extra for earthwork in hard soil as per specification and direction of E/I.
157Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
158Providing designation 75A brick work inC.M (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
159Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
160Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
161Reinforcedcementconcreteworkinbeams,suspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
162Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
163Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I.
164Providing TMT Steelreinforcementof 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage ofM.S. Rods (straight or in coils) to work site, cutting bending and bindingwith annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specificationand direction of E/I
165(a) 10 mmTMT bar FE 500 ( Only Valid for SAIL & TATA Steel )
166Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
167Providing 12mm thick cement plaster (1:4) with clean coarse sand ofF.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as perbuilding specification and direction of E/I.
168Providing 1.5 mm thick cement punning including curing, carriage of water with all leads and lifts of water as perbuilding specification and direction of E/I.
169Supplying fitting & fixing H.C.I. pipes with ear of approved make confirming to I.S.I. 1729 including supplying nails and bobins short pieces, cutting loose collars lead and yarn for making lead caullked joints, cutting pipes to size including earth work or scaffolding where necessary etc all complete as per spectification & direction of E/I.
170( a ) 100 mm dia.
171Providing and laying brick bats in soakpit with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.
172Supplying, fitting and fixing C.I. cover with frame for mane hole and inspection chamber with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I. (a) Size 600 x 450 mm (Wt. 25 Kg).
173Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
174Bricks
175Coarse sand
176Stone Chips
177Cement
178Steel
179Section-IV (Deep Bore Well) 2 Nos.
180Suppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site.
181From 0.0M to 50.0 M belew G.L
182From 51.0 M to150.00 M belew G.L
183supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe itc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc all complete job.
184Supplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump.
185Submersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages 2.0 HP
186Supplying Fully Automatic Starter to operate induction motor working on 415v, 3 phase ,50 hz with no volt coil , Over load element , ON-OFF push buttons with necessary materials and connected to supply etc complete starter with original sheet steel encloser as per IS: 3914. F.A.S.D. Starter
187FR PVC insulated 3 core 4 sq.mm. copper wire.
188Supplying & lowering 40mm da column G. I. pipe with all complete job.
189Section-V Rain Water Harvesting
190Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
191Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classificationofsoil iten _B)
192Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
193Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
194Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
195Providing designation 75A brick work inC.M (1: 4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
196Stone Metal at quarry site .. Traxes and royalty all complete as per building specification and direction of E/I. 90 mm Gravel filling
1970.90 M stone Boulder filling
198Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
199Providing 12mm thick cement plaster (1:3) with clean coarse sand ofF.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as perbuilding specification and direction of E/I.
200Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I.
201Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (TMT Fe 500 (Only valid for SAIL & TATA Steel )
202Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
203Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
204110 mm bend
205Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete (110 mm )
206Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
207Bricks
208Coarse sand
209Stone Chips
210Cement
211Steel
212Basic rate for 125/115 mm dia drilled Tube Well for drilling in all kinda of Soil and rock for installation o hand pump with DI rings all complete including supplyin all materials, labours , tools drilling rigs air compressor and equipments s well as fuel li\ubricant for making125/115 mm dia boring etc and cost of transporting rigmachine and other vechile up to site of work including contrctor profit & OH chares as per specification and directtion of Engineer Incharge(basic rate)
213Drilling upto 30 M depth below G.L in Rulararea
214Supplying all materials labours equipments for lowering 125 mm dia blue UPVC Casing Pipe as casing for protecting the sides from falling during the process of drilling all complete including carrriage of materials to work site (Basic Rate)
215S/M/L forF/f wire mesh pipe
216Section-VI Approach Road (25 Metre.)
217Excavation in Soil by Manual means. (Excavation for foadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 1000 metres.) (ii) Including Royalty @ Rs. 27.48 per cumthe cost of watering, rolling & compaction
218Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
219Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
220Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 5.3.1.1 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
221Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
222Bricks
223Coarse sand
224Stone Chips
225Cement
226Electrical Installation Work
227SectionVII Note:- (1)PVC insuleted copper conductor cable of make:-Havell"s/HPL/Polycab/Mescab/Anchor (2)PVC conduit of thikness 1.5mm/2mm for wiring:-Polycab/Arkaylitel/Saini star (3)Switches/soket outlet for piano type:-Anchor/ Cona/Havells/HPL (4)Switches/soket outlet for modular type:-Roma(Anchor/wood)/Havell"s(carbtree)/ Hpl/Philips/Cona (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:-Havell"s/Hpl/L&T/Legrand/C&S (6)XLPE/PVC aramoured cable:-Havell"s/polycab/capital/V-guard (7)Electrical fitting/fixtures:-Bajaj/Philips/Crompton/wipro/Hpl (8)All internal wiring work should be recessed(conseeld)
228Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
229Group B
230Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVCInsuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required.
231Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
232Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
2332x1.5 sq mm+1x1.5 sq mm earth wire (for 2 set of 5 amp switch and socket)
2342x2.5 sq mm+1x2.5 sq mm earth wire (for circuit wiring)
2352x6.0 sq mm+1x6.0 sq mm earth wire (for sub main wiring LDB)
2362x10.0 sq mm+1x6.0 sq mm earth wire (for sub main wiring PDB)
2372x16.0 sq mm+1x6.0 sq mm earth wire (for submain wiring PDB G FLOOR)
2384x2.5 sq mm+2x2.5 sq mm earth wire (for building outer light)
239TV cable in existing conduit :- Supplying and drawing co-axial TV cable RG-6 grade copper conductor,PE insulated,withPVC sheath in the existing recessed PVC conduit as required.
240S/F PVC conduit :-supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .
24120mm
242S/F PVC/G.I. boxes :- Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc as required .
24375mm x 75mm x 50mm deep/ (4" x 4")
244S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
2455/6 amps, one way switch
2465/6amps, 3 pin socket outlet
247TV antenna socket outlet
248S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
249S/F Modular type blanking plate:-Supplying and fixing modular blanking plate on the existing modular plate switch boxexcluding modular plate etc, as required.
250S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
2511 or 2 module(78mm x 78mm x 45mm)
2526 module(78mm x 205mm x 50mm)
253S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and coverin front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switchconection painting etc, as required.
254S/F ceiling rose:- Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
255S/F Batten holder:- Supplying and fixing batten/angle holder including connection etc, as required.
256Errection on incandescent light fitting:- Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
257S/F Dingdong Call bell :- Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required.
258ITC exhaust fan up to 450 mm, sweep:- Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.
259S/F S.P. MCB DB:- Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
26012 Way,Double door
261S/F "B" series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, "B" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2626/32 amps,single pole, "B" SERIES
263S/F "C" series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, "C" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2646/32 amps,single pole, "C" SERIES
26540 amps ,DP
26650/63 amps, DP
267P/F M.V. danger notice plate:- Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required.
268Copper Earth plate electrode:- Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke)
269S/L 8 SWG copper wire ground :- Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
270P/F G.I. lightning conductor finial:- Providing and fixing of lighting cnductor finial, made of 25 mm dia 300mm long, copper tube having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.
271Reverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required.
272P/F G.I. lightning conductor tape in horizontal run:- Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(For horizontal run)
273P/F G.I lightning conductor tape in vertical run:- Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(for vertical run)
274P/F Testing joint for G.I. lighting conductor:- Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with 4 nos.of G.I. bolts, nuts, chek nuts and spring washers etc complete as required.
275Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm.but not exceeding95sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
276Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)
27750 sq.mm. 3.5 core
27895 sq.mm. 3.5 core
279Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
280Supplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
2813½ X 50 sq. mm (35mm)
2823½ X 95 sq. mm (45mm)
283Providing of 12"" (300 mm)exhaust fan of make bajaj/havells/usha/crompton
284Providing of 15"" (380 mm)exhaust fan of make bajaj/havells/usha/crompton
285Providing of 16"" (400 mm) Wall fan of make bajaj/havells/usha/crompton
286Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
28715/16 Watt LED Bulb
288S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
2891200 mm (48") Ceiling Fan of make bajaj/havells/usha/crompton/polar
290SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
29110/12 W LED Batten of make bajaj/havells/crompton/C&S
29220/22 W LED Battenof make bajaj/havells/crompton/C&S
293SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
29490 /100 W LED Street light of make bajaj/havells/crompton/C&S
295SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
29615/16 W LED Round Down Lightof make bajaj/havells/crompton/C&S
297Design manufacture, supply installation, testing and commissioning of 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proof complete with all inter connections small wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT"s, PT"s, etc. The panels shall be got fabricated only from panel builders having 7 tank process finishing system and CPRI approved certificate for similar LT Panel.
298LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets) each with following:
299INCOMING
300160 amps, 35 KA fixed thermal seting
301200 amps
302160 amps, 4 pole change over
303OUTGOING
30440 amps ,DP
30550/63 amps, DP
3066/32 amps ,DP
30740 amps 4 pole Isoletor
308OTHER ACCESSOSRIES
309DIGITAL VOLT METER 500V(3phase class 0.5)
310DIGITAL A METER 500V(3phase class 0.5)
311COPPER WIRE 1.5MM
312COPPER WIRE 6MM
313COPPER WIRE 10MM
314COPPER WIRE 25MM
315LED INDICATOR LAMP R/Y/B/G
316C.T COIL OF CT ratio 500/5 IS2705 part -3
317LT PANEL(Waterproof):-Supplying, designing, manufactored Double Door LT Panel fabricated out of 2mm thick(14SWG) CRCA sheet steel, dust and vermin proofwith reinforcement of suitable size iron channel, size 75mmx75mmx6mm with proper lifting arrangement effecting proper connection of all incomer and out going (IP-43) fully compartmentalized cubical type (folded joints construction), wall floor mounted, totally enclosed, extendable on both sides, switch board and suitable for use on 415V, 3 phase, AC Supply, 4 wire, 50 C/S, system having 36 KA fault capacity, housed with incoming,Steel Stand, interconnection, interlocking between feeders etc. space for 3 Phase Energy metersas required.The sheet steel under go minimum 7 tanks treatment followed by finishing of powder coating of minimum 60 micron thickness, duly compartmentalized cubical panel, 2 Nos. earth studs. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.The pannel shall be interlocked with switchgear.The gap between live part of the Panel shall be minimum 35mm.All openings shall be covered by soft rubber gasket (metal based neoprene) having structural re-inforcement with suitable Angle/Channel/T/Flat sections, hinged and lockable doors enclosure shall be galvanized.
318Add 18% GST
319Add 1% Lebour Cess
Disclaimer :