Tender For Provn Of Reading And Yoga Rooms In Dsom And I And Replacement Of Asbestos Cemented Sheet In Otm In T-11 Csd Plinth Area Of Bldg And Otm T-13 Mi Room Plinth Area Of Bldg At 127 Inf Bn (Ta) Under Ge Dehradun., dehradun-Uttarakhand

Military Engineer Services-MES has published Tender For Provn Of Reading And Yoga Rooms In Dsom And I And Replacement Of Asbestos Cemented Sheet In Otm In T-11 Csd Plinth Area Of Bldg And Otm T-13 Mi Room Plinth Area Of Bldg At 127 Inf Bn (Ta) Under Ge Dehradun.. Submission Date for this Tender is 17-02-2024. Building Work Tenders in dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

41761799
Corrigendum : Tender For Provn Of Reading And Yoga Rooms In Dsom And I And Replacement Of Asbestos Cemented Sheet In Otm In T-11 Csd Plinth Area Of Bldg And Otm T-13 Mi Room Plinth Area Of Bldg At 127 Inf Bn (Ta) Under Ge Dehradun.
Open Tender
Indian
Uttarakhand
dehradun
17-02-2024

Tender Details

Provn Of Reading And Yoga Rooms In Dsom And I And Replacement Of Asbestos Cemented Sheet In Otm In T-11 Csd Plinth Area Of Bldg And Otm T-13 Mi Room Plinth Area Of Bldg At 127 Inf Bn ( Ta ) Under Ge Dehradun.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

BOQ Items

Name of Work:-Provn of reading and yoga rooms in DSOM&I and replacement of asbestos cemented sheet in OTM in T-11 CSD plinth area of bldg and OTM T-13 MI Room plinth area of bldg at 127 Inf Bn (TA) under GE Dehradun.
Sl. No. Item Description
1Excavation in trenches in any type of soil , n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
2Material and labourfor Cement concrete1 :4:8 type D-2 (40 mm graded stone aggregate) as in foundations, filling and mass-concrete complete all as specified and directed.
3Material and labourfor Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
4Material and labourfor Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and directed.
5Material and labourfor Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
6Material and labourfor Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
7Material and labourfor Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
8Material and labourfor RCC M-25Design mix{ using 20 mm graded stone aggregate) as in Foundations etc, including rafts, footings, foundation beams, plinth beams, bases for columns etc and mass concrete complete all as specified and directed by Engineer-in-Charge
9Material and labourfor RCC M-25Design mix { using 20 mm graded stone aggregate) in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge
10Material and labourfor RCC M-25Design mix { using 20 mm graded stone aggregate) in beams,cantilevers,wall bends, bressummers, lintels over 1.5m span complete all as specified and directed.
11Material and labourfor RCC M-25Design mix { using 20 mm graded stone aggregate) in chajjas complete all as specified and directed.
12Material and labour RCC M-25 desigh mix (using 20mm graded aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and this like complete all as specified and directed by Engineer-in-Charge.
13Material and labourrendering 15mm thick on cement mortar 1:3 mixed with water proofing compound finished fair faces of brick/chajja, roof projection/facia even and smooth complete all as specified and directed.(WPC will be measured and paid separately).
14Supply only water proofing compound@ 0.20 ml per bags of cement complete all as specified and directed.
15Material and labourfor Mild steel TMTbars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
16All as per tiem No 15 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
17Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
18Use and waste for formworktosides of pillars, posts, struts, piers, columns and stanchions etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
19Use and waste for Formwork to sides and soffits of floor or roof beams, wall bend beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed.
20Use and waste forformworkto soffits of suspended slabs such as chajjes and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surface complete all as specified and directed by Engineer-in-Charge.
21Use and wasteforformworkto soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surface complete all as specified and directed by Engineer-in-Charge.
22Use and wasteforformworktoedges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
23Material and labourfor Brickwork with subclass ‘B’ bricks, old size straight or curved on plan exc 6m mean radius, built in 1:6 complete all as specified and directed.
24Material and labourfor Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
25Returning, filling in soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
26Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting pointcomplete all as specified and directed.
27Material and labour15 mm thick rendering in cement mortar (1:6) on fair faces of brick work finished even and smoothwithout using extra cement complete all as specified and directed.
28Material and labourfor 15 mm thick rendering in cement mortar 1:4 on on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed.
29Material and labourfor Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
30Material and labourfor 75mm thick cement concrete 1:2:4 Type B-1using 20 mm graded stone agg in floor etc and finished the top surface of concete by brooming complete all as specified and directed.
31Material and labourfor 25 mm thick cement concrete1:2:4 type B-1 ( 20 mm graded aggregate) as in sub floor etccomplete all as specified and directed.
32Material and labourfor bedding layer of chemical adhesive of minimum 6 mm thickness, after roughning of floor surfaces by picking, sweeping clean and washing down with water complete all as specified and directed. (Make of adhesive : Balendura/ Pedilite/ Laticrete)
33Material and labourfor Vitrified Digital Ceramic tiles Double charged 10 -12 mm thick (square/ rectangular) polished jointless digital type , area of each tilesexceeding 0.42 sqm, n.exc 1.00 Sqm in floors etc. set and jointed by chemical adhesive and joints to be raked open after fixing of tile, cleaned and filled with white cement and coloured pigment or any other finish complete all as specified and directed.Make : Somany,Orient Bell, Johnson
34All as per item No 33 here-in-before but as in skirting/dado over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
35Material and labourfor Granite 18-20mm thick of any type ( table rubbed and polished) in cooking platform, steps, jambs pillars, window cill,and like in cement mortar 1:4 incl pointing in white cement complete all as specified and directed.
36M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggreate), 75 mm thick as in plinth protection, finishing the surface even & fair without using extra cement the plinth protection shall be laid in alternate bays n exe 2 Sqm, 10mm joints shall be provided, joints shall be filled with bitumen mastic, bitumen mastic comprise of 1 Part of Hot bitumen 85/25 grade and 3 parts of sand all by weight complete all as specified & directed including demolition of concrete complete all as specified and directed.
37Material and labourfor Preparation of already prepared surface of wall and applying two coat of oil bound distempercomplete all as specified and directed.
38Material and labourfor preparation of wall and applying exterior grade wall care putty 2 to 3mm thick to make the surface smooth as specified and directed by Engr-in-Charge
39Material and labourpreparation of new plastered surfaces of external wall and application of two coats of1st quality exterior emulsion weather coatpaintsover a coat of alkaliresistant priming paint complete all as specified and directed.
40Supply and fix for false ceiling with Everest Fibre Cement Designer tile Ivory painted (High pressure steam cured) of 6mm thickness (as per IS: 14862) of size 595 x 595 mm and any one of the design (Ocean, lake & hill, cascade or electra ) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and 15 x 32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross "T" of size 15 x 32 mm made of 0.30 mm sheet, 1200 mm long spaced between main "T" at600 mm c/cto form a grid of 1200 x 600 mm and secondary cross "T" of length 600 mm and size 15 x 32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200 x 600 mm panel to form grids of 600 x 600 mm and wall angle of size 15 x 20mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including, required cutting/making , opening for services like diffusers, grills, light fittings, fixture, smoke detectors etc.Main "T"runners to besuspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3 mmdia with galvanised butterfly level clips, spaced at 1200 mm c/c along centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/Sqm, including refixing of any type of wirecomplete all as specified and as directed by Engr-in-Charge.
41Providing & fixing false ceiling ofDesigner tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos "T" of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c toform a grid of1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mmand laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main "T", bottom exposed width of 15mm of all "T"" sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, including taking down existing ceiling of any type all complete at all heights as per direction of Engineer-in-Charge.
42Supply and fixaluminium alloy powder coated door made out of hollow extruded aluminum section as mentioned below. Each door having 02 Nos Disc or D type handle, 02 Nos aluminum tower bolt 200mm size, one brass mortice lock of six lever with key in duplicate regulated by double action hydraulic floor spring heavy duty (Make : Sandhu/Titz ) shutter to be partly glaze with 5mm thick tined coloured glass in upper pannel and partly pannelled with 12 mm thick both side laminated particle board in lower pannel fixed with glazing clip, rubber beading/gasket, anodised aluminum beading screw complete all as specified and directed at site. Chowkhat frame : 101.60x44.45x1.60mm, Shuter verticle style : 85x44.45x1.56mm, Shutter top rail and bottom rail : 114.30x44.45x1.55mm Make : (i) Anodised aluminum section : Jindal/Hindalko/Indalco (ii) Particle board : Navipan/Puratuff/Kitlam (iii) Glass : Saint gobain/Modi guard/Tata
43Supply and fixfor powder coated aluminium window alloy coated standared hollow section as mentioned below window frame (bombay sliding) with two glazed shutter and one nos wire gauged shutter sliding type with aluminium sections as per series -A (15mm)3 track of Jindal section numbers for sliding windows, and glazed with tinted glass coloured glass 4m thick , fixed with glazing clips, rubber beading / gasket anodised beading, srew and lock type handle of size 75mm, 2 Nos aluminium tower bolt 150mm long etc complete all as specified and directed.shutter Top & bottom size :37.50x15x1.60mm, shuter inner lock size 37.50x15x1.60mm, chowkhat bottom size 50.30x26x1.20mm, chowkhat top & size 50x30x26x1.00mm and making good of wall surface with matching to existing surfaces complete all as specified and directed. Make: Anodised aluminium section: Joindal/Hindalko/Indalco. Glass: Sant gobin/Modi guard/Tata.
44Supply and fixpowder coated aluminium grill with frame fixed to by means stainless steel screws ,complete all as specified and directed.
45Supply and fix0.5 mm thick prepainted galvalume alumininum zinc coating GI based corrugated steel sheet of an colour having tensile strenght of 550 Mpa as in roof covering /Cladding to wall fixed with self tapping complete all as specified and directed.
46Supply and fixPre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified all directed by the Engr-in-Charge.
47Material and labourfor steel work in tubular post, trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
48Supply and fixRoof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming Fe-290 (Gde E-165) complete all asspecified and as directed.
49Material and labour forPreparation of new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a cost of red oxide primer complete all as specified and directed.
50S & F10 mm thick non skid rubber tiles of compsitionn of Recycled rubber -97 % Urethane Binder-3% of tensile strenth 350 PSI Electrical resistance fixed with adhessive complete all as specified and directed.
51Material and labourfor POP false ceiling with cornice of approved design including GI Frame work and wiremesh complete all as specified and directed.
52Supply and fixfor 5mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and directed.
53Dismantling of Asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings complete all as specified
54Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed
55Suply and fix Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, post, pipes; fixed with angle cleats or other connecting plates Fe-290 (Gde E-165 complete all as specified and directed
56Material and labour PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching to drain, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and directed.
57Demolition of Brickwork or stone/bou-lder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified
58Material and labour for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified
59Material and labour for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified in SSR Part I and directed by Engr-in-Charge.
60Material and labourpoint wiring with 1. 5 Sqmm PVC insulated unsheathed multistranded single core copper conductor cable in PVC surface conduit wiring and incl making good with factory made modular pressed terminal box (recessed) with 1.5 Sqmm PVC insulated copper conductor earth continuity wire for one light/fan point controlled by one switch complete all as specified and directed.
61All as per item No.60 here-in-beforebut for one pin 5 A socket outlet independent board complete all as specified and directed.
62All as per item No.60 here-in-beforebut for one pin 5 A socket outlet on same board complete all as specified and directed.
63All as per item No.60 here-in-beforebut with 4 Sqmm cable for one 6 pin 15A socket outlet point on independent board complete all as specified and directed.
64Supply and fixswitch modular 6 Amps 230 Volts one way switch complete all as specified and directed.
65Supply and fixswitch modular 10 Amps 230 Volts 2 way switch complete all as specified and directed.
66Supply and fixSocket 6 Amps AC 230 Volts 2/3 pin combined 2 modular type complete all as specified and directed.
67Supply and fixSocket6A/16 Amps-2/3 pin AC 230 Voltsmodular type complete all as specified and asdirected.
68Supply and fixSwitchmodular type AC 230 volts 16 Amps one way complete all as specified and asdirected.
69Supply and fix Modular white cover plate with frame 2 module and metal flush box 2 module complete all as specified and asdirected.
70All as per item No.69 here-in-beforebut 3 modulecomplete all as specified and directed.
71All as per item No.69 here-in-before but 4 module complete all as specified and directed.
72All as per item No.69here-in-beforebut 6 modulecomplete all as specified and directed.
73All as per item No.69 here-in-before but 8 modulecomplete all as specified and directed.
74All as per item No.69 here-in-beforebut 12 modulecomplete all as specified and directed.
75Supply and fixceiling rose surface bakelite 3 terminals of size 65x25mm. complete all as specified and directed.
76Supply and fixLED tube light High-quality materials and design. Extruded aluminium housing enhances safety. High quality PC Diffuser. Reliable and robust housing structure, maximize the endurance over the life time slim Integrated design, easy to install Efficacy: 125 lm/W. complete all as specified and directed. Make Crompton Model BRIGHT LINEA Cat Part No - CCS-100-20-65-HL2-DP-NWH or equivalent Note : Light fitting should be not less than 125 lm/W & of Alluminiun body.
77Supply and fixLED Tube Light (Mirrorlight fitting) type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
78Supply and fixDecorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base. LHFOAJE1TZ1I060 1 N x 9 W LED Lamp/1 N x 7.5 W LED filament lampcomplete all as specified and directed.
79Supply and fixLED luminaire 600x600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver 3 core flexible copper conductor complete., complete all as specrified & directed
80Supply and fixLEDdown lighter consealed ceiling light 12W Sky Spot COB (WW) complete all as specified and directed. (Sample should collect from JE& AGE E&M)
81Supply and fixLED Sceneary Light complete all as specified and directed. Make - Luker Model LMCL12 (Sample should collect from JE& AGE E&M)
82Supply and fixLEDDecorative, surface mounting, dome shaped pendant in green & black finishes, 7.5 W A60 LED Filament Lamp Black along twith its conneccting & hanging arrangements . Make Havells Cat No LHFHDPE1TN1K020 (Sample should collect from JE& AGE E&M Test certificate to be submitted)
83Supply and fixLED strip tube type out door type of 50 Mtr Roll PVC insulated , 230 volt, including all accessories like connectors, mounting clips, adaptor complete all as specified and directed.
84Supply and fix wall mounted fans complete with all accessories ,400 mm . BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz of ,connector block of fan including fixing ofFan hooksand necessarynuts and bolts complete all as specified and directed.
85Supply and fix Exhaust fans AC single phase 230/ 240 V of size 250 mm sweep,50 Hz with louvercomplete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 blockcomplete all as specified and directed.
86Supply and fix Water heater storage type,electric, capacity 25 litres AC single phase 230/ 240 V o and connecting upincluding making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 blockcomplete all as specified and directed.
87Supply and fixsheet metal enclosure TPN for DB"s when MCB"s to be used 8 way with 200 amps bus bar anddouble door completeall as specified anddirected.
88Supply and fixsheet metal enclosures SPN 240 volt 8 way with suitable rated bus bar for Single door IP-43DB"scomplete all as specified and directed .
89Supply and fixMCB TPN240 Volt 10 KA63 Amp conforming to IScomplete all as specified & directed.
90Supply and fixMCB SPN240 Volt 10 KA40 Amp conforming to IScomplete all as specified & directed.
91Supply and fixMCB SP 6 to 32A complete all as specified and directed.
92Material and labourfor submain wiring with 3 runs(N+P+E) of 1.5 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductorFRLS cable 1100 volts grade drawn throughand including concealed/surfacePVC conduit pipe of medium duty not less than15 mm dia including necessary PVCconduit specials and connecting with suitable size thimble complete all as specified anddirected. Note:-3 runs of1.5 Sqmm size PVC copper cable, and one run of PVC conduit shallbe measured as one unit length.
93All as per item No 92 here-in-before, but 3 run of copper conductorFRLS cable 2.5 Sqmm complete all as specified and directed.
94All as per item No 92 here-in-before, but 3 run of copper conductorFRLS cable 4 Sqmm complete all as specified and directed.
95All as per item No 92 here-in-before, but 3 run of Cable6 Sq mm. Note:-3 runs of6 Sqmm size PVC copper cable, and one run of PVC conduit shallbe measured as one unit length complete all as specified and directed.
96All as per item No 92 here-in-before, but 6 run of 6 Sq mm (3run -Phase, 1 for Neutral & 2 Runs for Earth with recommended colours)and drawn through not less tha 32 mm dia PVC conduit complete all as specified and directed. Note:-6 runs of6 Sqmm size PVC copper cable and one run of PVC conduit shallbe measured as one unit length.
97Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edgeof the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab54 cm x 54 cm x 5 cm reinforced with 8 mm dia.TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
98Supply and fixSheet metal enclosures with socket plug top and MCB" SPN enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB complete all as specified and directed.
99Supply, install, testing & commissioning of hi wall split units indoor/outdoor (Hot & Cold model) complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity complete all as specified and directed.
100Supply and install Wall mounted Digital voltage Stablizer 5 KVA for split type 2 Ton AC 230 Volts 50 Hz,complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail