Military Engineer Services-MES has published Tender For Special Repair To Bldg No. P-16 Lokhart Line Of 346 Fd Regtunder Ge (West) Bareilly. Submission Date for this Tender is 12-02-2024. Building Work Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41761569
Corrigendum : Tender For Special Repair To Bldg No. P-16 Lokhart Line Of 346 Fd Regtunder Ge (West) Bareilly
Open Tender
Indian
Uttar Pradesh
bareilly
12-02-2024

Tender Details

Tender For Special Repair To Bldg No. P-16 Lokhart Line Of 346 Fd Regtunder Ge ( West ) Bareilly ; 1 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Not Exceeding 1.5 Sqm Each Including Iron Mongries, Hold Fast Etc Andincluding Making Good Disturbed Portions Of Walls To Match The Existing Surface Complete All As Specified And Directed. 2 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Exceeding 1.5 Sqm But Not Exceeding 4.0 Sqm Each Including Iron Mongries, Hold Fast Etc And Including Making Good Disturbed Portions Of Wallsto Match The Existing Surfacecomplete All As Specified And Directed. 3 S&F Pressed Steel Frames For Doorof Size125mmx60mm ( Using Pbi Sheet1.25Mm Thick ) With One Or More Rebates Including Filling And Compaction With Pcc 1:3:6 Type C-1 ( Using 20 Mm Graded Stone Aggregate ) Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc, Complete With And Including Two Coats Of Wooden Texture Finished Paint Over A Coat Of Red Oxide Primer On The Frame Surface Complete All As Specified And Directed 4 S & F 30 Mm Thick Factory Made Flush Shutters, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Including Teakwood Lipping 6Mm Thick Fixed With Nails Complete All As Specified And Directed. 5 M & L For 35Mm Thick Plain Framed Glazed And Skeleton Shutter Of Ist Class Hard Wood ( Shisham ) Open Rebated& Prepared To Receive Glass, Gauge Etc, Without Sash Bar Edges Of Framingplain Chamfered Or Rounded Fitted With Cut And Mitered Beads For Securing Glass Etc, Of 2Nd Class Hard Wood , Members Of Shutters As Specified In Ssr Part - Isection 8 Clause 8.24 ( A ) Fitted To Chowkats Complete All As Specified And Directed. 6 Supply And Fix Solid Pvc Door Frame Of Size 50Mm X 47 Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With Mild Steel Square Tube 47X47mm ( 19 Gauge ) All As Specified And Directed. 7 M&L For Factory Made Solid Panel Pvc Doorshutter 30 Mm Thick ( Style ) Consisting Of Frame Made Out Of One Side Prelam Pvc Sheet And Other Side Plain Pvc Sheet. Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing. 8 S&F Steel Windows With Pressed Steel Frame Of Size 95Mmx45mm ( Using Pbi Sheet1.25Mm Thick ) Side Hung Shutter Including Box Type Hinges With Steel Handle And Steel Peg Stay With Glazed Openable Shutter With Glazing Bar ( Open Out Side ) And Wire Gauged Openable Shutter Without Glazing Bar ( Open Inside ) Dovetailed Or Welded Complete All As Specified And All As Per Drg No Td / 088 Dt 07 Jan 2002 ( Note :- ( I ) Two Shutters Ie Wire Guaged And Glazed Shall Be Fixed In One Composite Frame And Both Shutter Shall Be Measured As One Unit ( Ii ) Rate For Filling Pcc 1:3:6 Type C1 ( Using 20 Mm Graded Stone Aggregate ) In Frame Deemed To Be Included In Quoted Rates ( Iii ) Ms Grill, Glass And Wire Mesh Shall Be Measured And Paid Seperatly Under Relevant Item Of Schedule. ) 9 S & F100 Mm Long Medium Weight, Cold Rolled Mild Steel Butt Hinges With Screws Complete All As Specified And Directed. 10 S & F200mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All Specified And As Directed. 11 S&F250mm Long Aluminiumsliding Door Bolts Plate Type With Bright Bolt Not Less Than 12Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, 04 Nos On Bolt Plate And 02 Nos On Staple Plate And Fix Complete All As Specified And Directed. 12 S & F 150 Mm Long Aluminium Alloy Handles, Cast Type, Anodised Complete All As Specified And Directed. 13 S & F Mild Steel 300 Mm Long Ordinary Rat Rail Rod Pattern Helical Door Springs, Incl Roller And Roller Plate Complete All As Specified And Directed. 14 S & F Galvanized Mild Steel Wire Cloth, 0.56 Mm Dia Of Wire And Average Width Of Aperture 1.18 Mm And Fixed With Tinned Stacks, Or Galvanized Wire Staples Complete All As Specified And Directed. 15 S & F Insheet Glass 3.0 Mm Thick, Ordinary Quality And Glazing With Oil Putty Or Wooden Beads Exceeding 0.5 Sqm In Each Pane Glazed With Putty Or Fixed With Beads Complete All As Specified And Directed. 16 Demolition Of Concrete In Ground Floors And Pavings N Exc 15 Cm Thickness ( Below Or Above Ground Level ) 17 M&L For 75 Mm Thickcement Concrete 1:3:6, Type C2, ( Using 40 Mm Graded Stone Aggregate ) As In Floor / Plinth Protection, Finish The Surface Even And Smooth Without Using Extra Cement Including Forming Necessary Joints 12 Mm Wide To The Full Depth Of Pcc At Every 3 Mtr And Every Change Of Direction And Filling The Same With Bitumen Filler 1:3 By Weight Complete All As Specified And Directed. 18 M&L For Plain Cement Concrete Type C1, 1:3:6 ( Using 20 Mm Graded Stone Aggregate ) As In Holdfast And Similar Work Etc. Complete All As Specified And Directed. 19 M&L For 75 Mm Thick Cement Concrete, Type C 2, 1:3:6 ( Using 40 Mm Graded Stone Aggregate ) As In Sub Base Of Floor And Finishing The Surface Even & Fair To Receive Top Layers Of Floor Complete All As Specified And Directed. 20 M& L For Providing Cement Concrete Chequred Tiles 25Cm X 25Cm X 22Mm Thick, Machine Pressed; Set Jointed And Pointed In Neat Cement Slurry Asin Floors, And Cut Complete All As Specified And Directed 21 M&L For Plain Cement Concrete Type B1 1:2:4 ( Using 20 Mm Graded Stone Aggregate ) As In Roof Kerbs, Coping, Benching Etc Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Complete All As Specified And Directed. 22 M&L For 40 Mm Thick Pcc 1:2:4 Type B1 ( Using 20 Mm Graded Stone Aggregate ) In Floorings Including Finishing The Surface Even And Smooth Using Extra Cement Complete All As Specified And Directed. 23 M&L Brick Work With Fly Ash Bricks ( Old Size ) As Per Is 12894 -2002 Straight Or Curved On Plan Exc 6 M Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And Directed. 24 Demolition Of Brickwork Or Stone / Boulder Masonry, Built In Cement Mortar Including Allquoins, Arches, Pillars, Etc, But Excluding Ashlar Facings, Dressed Stonework And Precast Concrete Articles 25 M & L Rendering 15Mm Thick On Other Than Fair Faces Of Brick Wall Or Concrete Surface In Cement Mortar 1:6 Finished Even And Smooth Without Using Extra Cement Complete All As Specified. 26 M & L Rendering 15Mm Thick On Brick Wall Or Concrete Surface In Cement Mortar 1:4 Mixed With Water Proofing Compound As Per ManufacturerS Instruction, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. ( Note:- Water Proofing Compound Shall Be Measured And Paid Saperately. ) 27 M & L Rendering 5Mm Thick On Ceiling In Cement Mortar 1:4 Finished Fair And Even Smooth Without Using Extra Cement Complete All As Specified 28 Supply Only Water Proofing Compound Conforming To Is Specification Complete All As Specified And Directed. 29 M&L For Non - Skid Ceramic Tiles 7 To 8 Mm Thick Area Of Each Tile Exc. 0.18 Sqm But N. Exc. 0.38 Sqm As In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Matchover And Including 15 Mm Thick Screed Bed 1:6 Cement Motarincluding Dismantling Of Existing Floor Complete All As Specified And Directed 30 All As Per Serial Item As Above But As In Vertical Surfaces Including Rendering 10 Mm Thickin Cement Mortar 1:4, As In Rendering Complete All As Specified And Directed 31 M&L For Coloured Printed Glazed Ceramic Tiles 7 To 8 Mm Thick On Walls Dado / Skirting ( Square / Rectangular ) Of 450X350 / 350X250 Mm Jointed And Pointed With Colouredcementto Match Including 10 Mm Thick Rendering Of Cement Mortar 1:4, Including Dismantling Of Old Existing Tiling Complete All As Specified Or As Directed. 32 M&L For Non Skid Ceramic Tiles 7 To 8 Mm Thick On Floor ( Square / Rectangular ) Of 400Mmx400 Mm Jointed And Pointed With Colouredcementto Match Over And Including 10 Mm Thick Screed Bed Of Cement Mortar 1:4, Including Dismantling Of Old Exsting Floor Complete All As Specified Or As Directed. 33 S&F Gi Tubing 15Mm Medium Grade With And Including All Fitting And Fixed Complete To Walls & Ceiling Or Laid In Floors Including Taking Up Or Down Steel Tubing And Remove From Site Complete All As Specified And Directed. 34 S&Fin Replacement 40 Mm Dia Low Density Polyethylene Pipes ( Ldpe ) Of Pressure Rating 6 Kgf / Sqcm Fixed Complete To Walls Ceilings Or In Floors Etc. 35 S&Fin Replacementfor Vitreous China Squatting Pan “Orissa” Pattern Size 580X440mm White With Integral Foot Restscomplete All As Specified And Directed. 36 S&F In Replacement Vitreous China Bowl Urinal Flat Back, Size Of 465 X 355 X 265 Mm White ( Minimum ) , With Grating And Union For Discharge Pipe Complete All Asspecified And Directed . 37 S&Fin Replacement Pvc Low Level Cistern 10 Ltr Cap With Inlet Ball Valve, Float And Handle Incl Bracket And Flush Pvc Pipe Of Low Or High Density Or Pvc 32 Mm Dia For Low Level Cisterncomplete All As Specified And Directed. 38 S&Fin Replacement Pvc Connections 15Mm Size With Ptmt Nuts Of Length 450Mm Complete All As Specified And Directed. 39 S & Fin Replacement Chromium Plated Stop Valves / Angle Valve Cast Copper Alloy, Screwed Down, High Pressure With Crutch Or Butterfly Handle Screwed Both Ends For Iron Pipes 15Mm Bore Complete All As Specified And As Directed. 40 S&F In Replacement Vitreous Chinawash Basin Of Suitable Sizeincluding Ssbottle Trap, Hdpe Waste Pipe Including Fixing On Counter With Ss Waste Couplingcomplete All As Specified And As Directed. 41 S&F In Replacement Fancy Type Glass Corner 300Mm Radius Of 10Mm Thick Toughned Glass With Railing Fixed With Fancy Type Screws Complete All As Specified And Directed. 42 S&Fin Replacement Pvc Waste Pipe For Wash Basin & Urinal With Complete All As Specified And Directed. 43 S&F In Replacement 15Mm Bore Chromium Plated Fancy Type Bib Taps, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule.Complete All As Specified And Directed. 44 S & Fin Replacement Chromium Plated Shower Rose Withor Without Swivel Joints, Any Size, Includingfixingto Steel Pipeor Union Size 125 Mmcomplete All As Specified And Directed. 45 S&Fin Replacement Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, D Type, 60 Cm Long Between Flanges Including Brackets Complete All As Specified. 46 S&Fin Replacement 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass Mounted On 6 Mm Thick Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screw And Cup Washer Complete All As Specified And Directed. 47 S&F 20 Mm Thick Granite Stone Slabs Mirror Polished Of Colour And Shade As Approved By Ge, Machine Cut Bedded & Jointed With Grey Cement Slurry And Pointed In White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Fixed As In Steps, Jambs, Pillars Window Cills, Cooking Platforms & The Like Etc Over And Including Screed Bed Of 15 Mm Thick 1:6 Cm Complete All As Specified And Directed 48 M&L Pvc Floor Trap 75Mm With Grating Incluing Jointing To Waste Pipe Fixed In Cement Concrete Type B1 ( 1:2:4 ) Complete All As Specified And Directed. 49 S&Fin Replacement Rotational Moulded Polyethylene Water Storage Tanks ( Tripple Layer And White In Colour ) Of 1000 Litre Capacity ( Cylinderical Vertical With Closed Top ) Hoisted And Fixed In Position All As Specified In Ssr Part-I. Complete All As Specified And Directed. 50 S&F Ball Valve 20Mm Bore High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High-Density Plastic Ball Screwed For Iron Pipe And Fixed, ( Minimum Weight 210 Gms ) . 51 S&Fin Replacement Gun Metal Globe Or Gate Valve With Iron Wheel Screwed Both Ends For Iron Pipe Of 20 Mm Dia All As Directed. 52 Material And Labour For Preparation Of New Plastered Or Pointed Surface Of Walls / Pillars / Cornices By Brooming Down Or By Sand Papering Or By Any Other Mean And After Preparing The Surfaces Applying Two Coats Of Cement Base Paint Over A Coat Primer As Approved Tint / Colour Complete All As Specified And Directed. 53 M&L For Applying Two Coats Of Oil Bound Distempering On Newly Plastered Wall Surfcae With Airless Electric Sprayers Over A Coat Of Primer Applied Using Airless Electric Sprayers Over One Coat Of Wall Care Putty Of 1 Mm Thickness Complete All As Specified And Directed. ( Note-Application To Be Done Through Authorised Applicator Of Manufacturer. ) 54 M & L For Applying Two Coats Of Oil Bound Distemper White Or Tinted On Old Decorated Or Undecorated Wall Surface With Airless Electric Sprayers Over A Coat Of Primerapplied Using Airless Electric Sprayer Over A Coat Of Wall Care Putty Of 1Mm Th. Including Preparation Ofsurfacesby Washing Rubbing Down And Stoping Of Distempered And Painted Surfaces Complete All As Specified And Directed. 55 M & L For Machine Cutkota Stone Slab Flooring 20-25Mm Thick Over Cement Screedbase15 Mm Thickcm 1:4 Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishingincluding Dismantling Of Old Exiting Tiles Etc. Complete All As Specified And Directed. 56 M & L For Kota Stone Slab 20-25 Mm Thick Full Length In Single Peice Without Joint In Riser Of Steps, Skirting, Dado And Pillar Laid Over Cement Screed And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Including Necessary Grinding, Rubbing And Polishing ( Mirror Finish ) And Bullnosing Over And Including Rendering Of 15 Mm Thick Cm 1:4Including Dismantling Old Tiles Etccomplete All As Specified And Directed. 57 M&L For Preparation Ofnew Steel And Iron Surfaces Of Any Description Not Otherwise Described Over 10Cm In Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Specified & Directed. 58 M&L For Granite ( Of Any Type ) Tiles 20Mmthick Machine Cut, Bedded Andjointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Grinding And Polishing Includingdismantling Of Old Tiles Complete All As Spd As Directed. 59 S & F4mm Thick E-Board Tiles For Insulation And Acoustic Purpose Of Size 600X 600Mm Fixed With And Including Anodised Gi Prepaintedsnap Grid With 25X25x1.5 Mm Thick Tee Section And 38X25x2 Mm Thick Angle With Hanging / Supporting Arrangements As In False Ceiling At Bottom At Spacing 60 Cm Centre To Centre Including Necessary Gi Cleats And 4Mm Dia Gi Wire As Suspender Fixed To Ceiling Not Exceeding 1.20 Mtr Centre Both Ways With Dash Fastners Complete And Making Good Disturbed Surfaces Complete Allas Specified And Directed. 60 Dismantling Boarding, Any Description, Fixed In Any Position With Nailscomplete All As Specified And Directed. 61 S&F Prepainted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Clading To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed. 62 S&F Prepainted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Clading To Wall, Fixed With Self Tapping Screws As Specified. Complete All As Specified And Directed. 63 Dismantling Of Asbestos Cement ( Corrugated, Semicorrugated, Etc. ) Sheets In Roof Coverings Complete All As Specified And Directed. 64 Dismantling Timber Scantlings 40 Sq. Cm And Over In Section, In Any Position Complete All As Specified And Directed. 65 S&F Rolled Sections As In Main And Cross Beams, Hip And Jack Rafters; Purlins Where Connected To Common Rafters And Running Railsand Guides For Sliding Doors;Fixed With Angle Cleats Or Other Connecting Platesetc. As In Structural Steelcomplete All As Specified And Directed. 66 M& L Second Class Hardwood ( Sal ) As In Scantlingfor Timber And Fixed As Clean Sawn Complete All As Specified And Directed. 67 Dismantling Structural Steel Work Including Doors, Gates But Excluding Framed Truss Etc. Complete All As Specified And Directed. 68 Refixingabove Item Sameafter One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. 69 Preparing Surfaces Of Wood And Wood Based Materials, New Or Old, Of Any Description And Girth, Not Otherwise Described And Treated With Creosotecomplete Al As Specified And Directed. 70 Taking Down Carefully Aluminium Point Wiring Any Type Including Battens If Any Except For Ceiling Or Where Not Feasible For Light / Fan / / Bell / Socket Or Power And Including Unscrewing From Board, Fitting And Fixture Such As Switches, Socket, Ceiling Rose, Lamp Holder, Pendants, Bracket And Regulator Etc And Removing Material From Site Including Making Good Disturbed Surface To Match With The Existing Surface Complete All As Specified. 71 Taking Down Carefully Unsv Main Switch Dbs Of Any Description Of An Size In Any Position Complete All Specified And Directed 72 Taking Down Submain Wiring Including All Accessories Complete All As Specified And Directed. 73 Material And Labour For Point Wiring With Single Corepvc Sheathed 1100 Volt Grade Frlsh Cable With Multi Stranded Copper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Drawn Through And Including Non Metallic Rigid Pvc Conduit Medium Duty Isi Markednot Less Than 20Mm Dia, With All Conduit Accessories, Screws, Rawl Plugs ( Concealed Conduit Wiring In Walls And Casing Capping On Ceiling Or Roof ) Including Pressed Steel Terminal Sunken Boxes Andcovered With 3 Mm Thick Plastic Laminated Sheet Coverof Suitable Size With New Brass Screwsfor Mounting Switch Sockets And Regulators And Drawing Continuous Earth Wire With And Including Pvc Sheathed 1100 Volts Grade Frlsh Cable With Strandedcopper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) And Connected To Main Earth Dolly Complete All As Specified For:- ( A ) One Light / Fan / Exhaust Fan Point Controlled By One Switch. 74 ( B ) One 5 Pin, 6 Amp Switch Socket Out Let Point On An Independent Board. 75 ( C ) One 5 Pin, 6 Amp Socket Out Let Point Controlled By One Switch On Same Board. 76 All As Per Item 73 Here In Before But For One 16 Amp, 6 Pin Switch Socket Out Let Independent With2.5 Sqmm Frlsh ( Nominal Area ) Pvc Unsheathed Copper Conductor Single Core Multistrandedincl 2.5 Sq Mm Frlshpvc Copper Conductor Single Core Used As Earth Continuity Conductoe Complete All Specified And Directed 77 S&F Switch Piano Flush Type 6 Amp Single Pole One Way Complete All Specified And Directed 78 S&F Socket Out Let 2 In 1 Flush Type 6 Amp 5 Pin Complete All Specified And Directed 79 S&Fswitch Piano Type 16 Ampflush Type 240 Volt Complete All Specified And Directed 80 S&Fsocketout Let 6 Pin 2 In 1, 6 / 16 Ampflush Type 240 Volt Complete All Specified And Directed 81 Supply And Fixing Ceiling Rose Pvc / Poly Carbonate, Isolated Body, Threeterminal Ac 230 Volts Complete All As Specified And Directed. 82 S&Ffan Regulator 150 Wattselectronic Flush Socket Type With Five Stepped Range Hum Freecomplete All As Specified And Directed . 83 M & Llamp Holder, Pvc / Poly Carbonate, Insulated Bodymodular Type With Back Plate Batten / Angle Type For Batten Fittings Complete All As Specified And & Directed 84 S&F In Replacementsurface Mounting Led Light Fitting Ac Decorative Box Type , 20 Watt, 4 Feet Including Connection With 23 / 0.0076 Three Core Pvc Flexible Cable Etc Complete All As Specified And Directed. 85 S&F In Replacement Led Lamp 12 Watt, 230 V , Ac Integrated Circuit Complete All As Specified And Directed. 86 M&L For Sub Main Wiring With Two Single Core 4.0 Sqmm ( Frlsh ) Copper Conductor Pvc Unsheathed Cable Medium Grade Including Pvc Conduit ( Appropriate Size ) Concealed In Wall For Sub Main Connection Including 4.0 Sqmm ( Frlsh ) Pvc Insulated Multistranded Unsheathed Copper Conductor Used As A Earth Wire To Common Earth And Connection To Earth Dolly Complete All Specified And Directed. ( Note : Two Runs Of 4.0 Sqmm ( Frlsh ) And One Run Of4.0 Sqmm ( Frlsh ) Copper Conductor Shall Be Measured As One Unit Length. ) 87 Taking Down Carefully Ceiling Fan And Keeping In Safe Custody For Refixing The Same At Site Afterbldg Repair With And Including One Coat Of Painting Of Ceiling Fans Complete, With Synthetic Enamel Paint By Spraying & Sevicing Complete All Specified And Directed 88 S&F In Replacement Mcb Spn 40 Amp 240 Volt, 10 Ka, B Curve Complete All As Specified And Directed. 89 S&F In Replacement Mcb Single Pole 6 To 32 Amp, 240 Volt, B Curve, 10 Ka Complete All As Specified And Directed . 90 S&F In Replacement Mcb Triple Pole And Neutral 40 Amps415 Volt, B Curve, 10 Ka Complete All As Specified And Directed. 91 Supply And Fix Flush Sheet Metal Enclosure Spn Db 8 Way With Double Door Ip-42 Protection Detachable Gland Plates, Flush Mounting For Mcb Fitted With Bus Bar , Earth Bar And Neutral Linkscomplete Including Taking Down Old Unsv All As Specified And Directed. 92 Supply And Fix Flush Sheet Metal Enclosure V Tpndb 4 Way 415 Vwith Double Door Protection Detachable Gland Plates, Flush Mounting For Provn Of Mccb 160 Amps Fitted With Bus Bar, Earth Bar And Neutral Links Complete Including Taking Down Old Unsv All As Specified And Directed. 93 Material & Labour For Earthing Complete Including Taking Out Old Unsv And Replacewith Galvanised Steel Earth Plate 600X600x 6Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Meters Below Normal Ground Level, Surrounded With Adequate Quantity Of Charcoal Dust Mixed With Salt To A Packed Thickness Of 15 Cm All Around The Plate Using 4 Mm Dia Gi Wire As Earth Wire Electrode Moulded And Rivetted To Earth Plate At One End And Connected To Main Switch / Control Switches Of Buildings At Another End, Gi Earth Wire Encased Inand Including 15 Mm Dia Gi Light Grade Pipe From Upper End Of Earth Plate Upto Main Switch Board Of Building Including 20 Dia Bore Gi Pipe Light Grade As Water Pipe From Earth Chamber Andincluding Excavation And Earth Work, Pcc 1:3:6 Typec1 Chamber And Ms Angle Iron Frame 40X40x3mm And Rcc Cover 40Mm Thick ( 1:2:4 ) Type B1 Using 20Mm Graded Stone Aggregate Reinforced As Per Electrical Plate No. 3 Of Ssr Part-I Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Feb-2024 Corrigendum 1 BOQ 12-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 66300.0 /-
Tender Value
INR 33.15 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR TO BLDG NO. P-16 LOKHART LINE OF 346 FD REGTUNDER GE (WEST) BAREILLY
Sl. No. Item Description
1Taking down Chowkats or frames with shutters (Without taking off shutters from the frames)not exceeding 1.5 Sqm each including iron mongries, hold fast etc andincluding making good disturbed portions of walls to match the existing surface complete all as specified and directed.
2Taking down Chowkats or frames with shutters (Without taking off shutters from the frames)exceeding 1.5 sqm but not exceeding 4.0 Sqm each including iron mongries, hold fast etc and including making good disturbed portions of wallsto match the existing surfacecomplete all as specified and directed.
3S&F Pressed steel frames for doorof size125mmx60mm (using PBI sheet1.25mm thick) with one or more rebates including filling and compaction with PCC 1:3:6 Type C-1 (using 20 mm graded stone aggregate) necessary fixing lugs, hinges, lock strike plate, etc, complete with and including two coats of wooden texture finished paint over a coat of red oxide primer on the frame surface complete all as specified and directed
4S & F 30 mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including teakwood lipping 6mm thick fixed with nails complete all as specified and directed.
5M & L for 35mm thick plain framed glazed and skeleton shutter of Ist class hard wood (Shisham) open rebated& prepared to receive glass, gauge etc, without sash bar edges of framingplain chamfered or rounded fitted with cut and mitered beads for securing glass etc, of 2nd class hard wood , members of shutters as specified in SSR Part - ISection 8 clause 8.24 (a) fitted to chowkats complete all as specified and directed.
6Supply and fix Solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube 47x47mm (19 gauge) all as specified and directed.
7M&L for factory made solid panel PVC doorshutter 30 mm thick (style) consisting of frame made out of one side prelam PVC sheet and other side plain pvc sheet. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
8S&F steel windows with pressed steel frame of size 95mmx45mm(using PBI sheet1.25mm thick) side hung shutter including box type hinges with steel handle and steel peg stay with glazed openable shutter with glazing bar ( open out side ) and wire gauged openable shutter without glazing bar ( open inside ) dovetailed or welded complete all as specified and all as per DRG No TD/088 dt 07 Jan 2002 (Note :- (i) Two shutters ie wire guaged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit(ii) rate for filling PCC 1:3:6 type C1(using 20 mm graded stone aggregate) in frame deemed to be included in quoted rates(iii) MS grill,glass and wire mesh shall be measured and paid seperatly under relevant item of schedule.)
9S & F100 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed.
10S & F200mm long Aluminium, anodised, barrel tower bolts of extruded section complete all specified and as directed.
11S&F250mm long aluminiumsliding door bolts plate type with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, 04 Nos on bolt plate and 02 Nos on staple plate and fix complete all as specified and directed.
12S & F 150 mm long Aluminium alloy handles, cast type, anodised complete all as specified and directed.
13S & F mild steel 300 mm long ordinary rat rail rod pattern helical door springs, incl roller and roller plate complete all as specified and directed.
14S & F Galvanized mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed.
15S & F inSheet glass 3.0 mm thick, ordinary quality and glazing with oil putty or wooden beads exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed.
16Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
17M&L for 75 mm thickcement concrete 1:3:6,type C2, (using 40 mm graded stone aggregate) as in floor/plinth protection, finish the surface even and smooth without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 mtr and every change of direction and filling the same with bitumen filler 1:3 by weight complete all as specified and directed.
18M&L for Plain Cement Concrete Type C1, 1:3:6 (using 20 mm graded stone aggregate) as in holdfast and similar work etc. complete all as specified and directed.
19M&L for 75 mm thick cement concrete, type C 2, 1:3:6 (using 40 mm graded stone aggregate) as in sub base of floor and finishing the surface even & fair to receive top layers of floor complete all as specified and directed.
20M& L for providing Cement concrete chequred tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry asin floors, and cut complete all as specified and directed
21M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in roof kerbs, coping, benching etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
22M&L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in floorings including finishing the surface even and smooth using extra cement complete all as specified and directed.
23M&L Brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
24Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including allquoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
25M & L rendering 15mm thick on other than fair faces of brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified.
26M & L rendering 15mm thick on brick wall or concrete surface in cement mortar 1:4 mixed with water proofing compound as per manufacturer"s instruction, finished even and smooth without using extra cement complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid saperately.)
27M & L rendering 5mm thick on ceiling in cement mortar 1:4 finished fair and even smooth without using extra cement complete all as specified
28Supply only water proofing compound conforming to IS specification complete all as specified and directed.
29M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exc. 0.18 sqm but n. exc. 0.38 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover and including 15 mm thick screed bed 1:6 cement motarincluding dismantling of existing floor complete all as specified and directed
30All as per serial item as above but as in vertical surfaces including rendering 10 mm thickin cement mortar 1:4, as in rendering complete all as specified and directed
31M&L for coloured printed glazed ceramic tiles 7 to 8 mm thick on walls dado/ skirting (square/ rectangular) of 450x350/350x250 mm jointed and pointed with colouredcementto match including 10 mm thick rendering of cement mortar 1:4, including dismantling of old existing tiling complete all as specified or as directed.
32M&L for Non Skid ceramic tiles 7 to 8 mm thick on floor (square/ rectangular) of 400mmx400 mm jointed and pointed with colouredcementto match over and including 10 mm thick screed bed of cement mortar 1:4, including dismantling of old exsting floor complete all as specified or as directed.
33S&F GI tubing 15mm medium grade with and including all fitting and fixed complete to walls & ceiling or laid in floors including taking up or down steel tubing and remove from site complete all as specified and directed.
34S&Fin replacement 40 mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/ sqcm fixed complete to walls ceilings or in floors etc.
35S&Fin replacementfor vitreous china squatting pan “ORISSA” Pattern size 580x440mm white with integral foot restscomplete all as specified and directed.
36S&F in replacement Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipe complete all asspecified and directed .
37S&Fin replacement PVC low level cistern 10 Ltr cap with inlet ball valve, float and handle incl bracket and flush pvc pipe of low or high density or PVC 32 mm dia for low level cisterncomplete all as specified and directed.
38S&Fin replacement PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
39S & Fin replacement chromium plated stop valves/Angle valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes 15mm bore complete all as specified and as directed.
40S&F in replacement Vitreous Chinawash basin of suitable sizeincluding SSbottle trap, HDPE waste pipe including fixing on counter with SS waste couplingcomplete all as specified and as directed.
41S&F in replacement fancy type glass corner 300mm radius of 10mm thick toughned glass with railing fixed with fancy type screws complete all as specified and directed.
42S&Fin replacement PVC waste pipe for wash basin & Urinal with complete all as specified and directed.
43S&F in replacement 15mm bore chromium plated fancy type bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.complete all as specified and directed.
44S & Fin replacement chromium plated shower rose withor without swivel joints, any size, includingfixingto steel pipeor union size 125 mmcomplete all as specified and directed.
45S&Fin replacement brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges including brackets complete all as specified.
46S&Fin replacement 600mmx450mm bevelled edge mirror of selected quality glass mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washer complete all as specified and directed.
47S&F 20 mm thick granite stone slabs mirror polished of colour and shade as approved by GE, machine cut bedded & jointed with grey cement slurry and pointed in white cement with admixture of pigment to match the shade of granite stone fixed as in steps, jambs, pillars window cills, cooking platforms & the like etc over and including screed bed of 15 mm thick 1:6 CM complete all as specified and directed
48M&L Pvc floor trap 75mm with grating incluing jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
49S&Fin replacement Rotational moulded polyethylene water storage tanks(tripple layer and white in colour) of 1000 Litre capacity (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I. complete all as specified and directed.
50S&F ball valve 20mm bore high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed, (minimum weight 210 gms).
51S&Fin replacement gun metal globe or gate valve with iron wheel screwed both ends for iron pipe of 20 mm dia all as directed.
52Material and labour for preparation of new plastered or pointed surface of walls/pillars/cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying two coats of cement base paint over a coat primer as approved tint/colour complete all as specified and directed.
53M&L for applying two coats of oil bound distempering on newly plastered wall surfcae with airless electric sprayers over a coat of primer applied using airless electric sprayers over one coat of wall care putty of 1 mm thickness complete all as specified and directed. (Note-APPLICATION TO BE DONE THROUGH AUTHORISED APPLICATOR OF MANUFACTURER.)
54M & L for applying two coats of oil bound distemper white or tinted on old decorated or undecorated wall surface with airless electric sprayers over a coat of primerapplied using airless electric sprayer over a coat of wall care putty of 1mm th. including preparation ofsurfacesby washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed.
55M & L for Machine cutkota stone slab flooring 20-25mm thick over cement screedbase15 mm thickCM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingincluding dismantling of old exiting tiles etc. complete all as specified and directed.
56M & L for Kota stone slab 20-25 mm thick full length in single peice without joint in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade including necessary grinding, rubbing and polishing (mirror finish)and bullnosing over and including rendering of 15 mm thick CM 1:4including dismantling old tiles etccomplete all as specified and directed.
57M&L for preparation ofnew steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
58M&L for Granite (of any type) tiles 20mmthick machine cut, bedded andjointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing includingDismantling of old tiles complete all as spd as directed.
59S & F4mm thick E-Board tiles for insulation and acoustic purpose of size 600x 600mm fixed with and including anodised GI prepaintedsnap grid with 25x25x1.5 mm thick Tee section and 38x25x2 mm thick angle with hanging/supporting arrangements as in false ceiling at bottom at spacing 60 cm centre to centre including necessary GI cleats and 4mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 mtr centre both ways with dash fastners complete and making good disturbed surfaces complete allas specified and directed.
60Dismantling boarding, any description, fixed in any position with nailscomplete all as specified and directed.
61S&F prepainted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws complete all as specified and directed.
62S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws as specified. complete all as specified and directed.
63Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
64Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
65S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running railsand guides for sliding doors;fixed with angle cleats or other connecting platesetc. as in structural steelcomplete all as specified and directed.
66M& L second class hardwood (sal) as in scantlingfor timber and fixed as clean sawn complete all as specified and directed.
67Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
68Refixingabove item sameafter one coat of synthetic enamel paint complete all as specified and directed.
69Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosotecomplete al as specified and directed.
70Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixture such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified.
71Taking down carefully UNSV main switch DBs of any description of an size in any position complete all specified and directed
72Taking down submain wiring including all accessories complete all as specified and directed.
73Material and labour for point wiring with single corePVC sheathed 1100 volt grade FRLSH cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI markednot less than 20mm dia, with all conduit accessories, screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof) including pressed steel terminal sunken boxes andcovered with 3 mm thick plastic laminated sheet coverof suitable size with new brass screwsfor mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade FRLSH cable with strandedcopper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:- (a) One light / fan/ exhaust fan point controlled by one switch.
74(b) One 5 pin, 6 Amp switch socket out let point on an independent board.
75(c) One 5 pin, 6 Amp socket out let point controlled by one switch on same board.
76All as per item 73 here in before but for one 16 Amp, 6 Pin switch socket out let independent with2.5 Sqmm FRLSH (Nominal Area) PVC unsheathed copper conductor single core multistrandedincl 2.5 sq mm FRLSHPVC copper conductor single core used as earth continuity conductoe complete all specified and directed
77S&F switch piano flush type 6 Amp single pole one way complete all specified and directed
78S&F socket out let 2 in 1 flush type 6 Amp 5 Pin complete all specified and directed
79S&Fswitch piano type 16 Ampflush type 240 Volt complete all specified and directed
80S&Fsocketout let 6 Pin 2 in 1, 6/16 Ampflush type 240 Volt complete all specified and directed
81Supply and Fixing ceiling rose PVC/ Poly carbonate,Isolated body, threeterminal AC 230 volts complete all as specified and directed.
82S&Ffan regulator 150 wattselectronic flush socket type with five stepped range hum freecomplete all as specified and directed .
83M & Llamp holder, PVC / Poly carbonate, insulated bodymodular type with back plate batten/angle type for batten fittings complete all as specified and & directed
84S&F in replacementsurface mounting LED light fitting AC decorative box type , 20 Watt, 4 feet including connection with 23/0.0076 three core PVC flexible cable etc complete all as specified and directed.
85S&F in replacement LED lamp 12 Watt, 230 V , AC integrated circuit complete all as specified and directed.
86M&L for sub main wiring with two single core 4.0 Sqmm (FRLSH) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLSH) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all specified and directed. ( Note : Two runs of 4.0 sqmm (FRLSH) and one run of4.0 sqmm (FRLSH) copper conductor shall be measured as one unit length.)
87Taking down carefully ceiling fan and keeping in safe custody for refixing the same at site afterbldg repair with and including one coat of painting of ceiling fans complete, with synthetic enamel paint by spraying & sevicing complete all specified and directed
88S&F in replacement MCB SPN 40 Amp 240 volt, 10 KA, "B" Curve complete all as specified and directed.
89S&F in replacement MCB single pole 6 to 32 Amp, 240 Volt, "B" curve, 10 KA complete all as specified and directed .
90S&F in replacement MCB Triple pole and neutral 40 Amps415 Volt, "B" curve, 10 KA complete all as specified and directed.
91Supply and fix flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral linkscomplete including taking down old unsv all as specified and directed.
92Supply and fix flush sheet metal enclosure V TPNDB 4 way 415 Vwith double door protection detachable gland plates, flush mounting for provn of MCCB 160 Amps fitted with bus bar, earth bar and neutral links complete including taking down old unsv all as specified and directed.
93Material & Labour for earthing complete including taking out old unsv and replacewith galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased inand including 15 mm dia GI "light grade" pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe "light grade" as water pipe from earth chamber andincluding excavation and earth work, PCC 1:3:6 typeC1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced as per electrical plate No. 3 of SSR Part-I complete all as specified and directed.