Tender For Additional/Alternator To Bldg No Et-111, Et-133, Et-367 And Certain Spl Rep ( Bldg ) Works At Rangia Mil Stn Under Ge Rangia, rangia-Assam

Military Engineer Services-MES has published Tender For Additional/Alternator To Bldg No Et-111, Et-133, Et-367 And Certain Spl Rep ( Bldg ) Works At Rangia Mil Stn Under Ge Rangia. Submission Date for this Tender is 01-02-2024. Building Work Tenders in rangia Assam. Bidders can get complete Tender details and download the document.




Tender Notice

41760754
Tender For Additional/Alternator To Bldg No Et-111, Et-133, Et-367 And Certain Spl Rep ( Bldg ) Works At Rangia Mil Stn Under Ge Rangia
Open Tender
Indian
Assam
rangia
01-02-2024

Tender Details

Additional / Alternator To Bldg No Et-111, Et-133, Et-367 And Certain Spl Rep ( Bldg ) Works At Rangia Mil Stn Under Ge Rangia

Key Value

Document Fees
INR 500 /-
EMD
INR 59500.0 /-
Tender Value
INR 29.73 Lakhs /-

BOQ Items

Name of Work: ADDN/ ALTRN TO BLDG NO ET-111, ET-133, ET-367 AND CERTAIN SPL REP (BLDG) WORKS AT RANGIA MIL STN UNDER GE RANGIA
Sl. No. Item Description
1M&L for taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each, complete all as specified and as directed by Engineer-in-charge.
2Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but not exc. 4.0 sq. m each, complete all as specified and as directed by Engineer-in-charge.
3Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
4Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed by Engineer-in-charge.
5M&L for demolition of reinforced Cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge.
6Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-charge.
7Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed by Engineer-in-charge.
8Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
9Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in-charge.
10Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed by Engineer-in-charge.
11Dismantling timber scantlings 40 sq. cm and over in section, in any position and in unframed work, complete all as specified and as directed by Engineer-in-charge.
12Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section and in unframed work, complete all as specified and as directed by Engineer-in-charge.
13Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge.
14Taking down existing old damaged WC pan of any type, cistern, urinal, basin of any description with all connections, complete all as specified and as directed by Engineer-in-charge.
15Taking down Bib tap, Pillar tap, Stop cock, Shower rose, Health faucet, mixer of any description, complete all as specified and as directed by Engineer-in-charge.
16M&L for Taking up or down 15 & 20mm dia steel/ GI tubing and connections, including cleaning for refixing or removal to store, complete all as specified and as directed by Engineer-in-charge.
17M&L for Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed by Engineer-in-charge.
18Demolition and breaking up of 75-100mm dia drain pipes (CI/ AC /PVC) set in cement mortar/ rubber ring jointed in any position, complete all as specified and as directed by Engineer-in-charge.
19M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
20M&L for Returning,filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
21M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
22M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation or Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge.NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
23M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
24M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajjas, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
25M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
26M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
27M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, chajjas, etc. also splays between floors and beams, etc., rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
28M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
29S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
30S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
31S&F of Mild Steel work in tubular trusses/ posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge.
32All as per Item No. 31 here-in-above, but for erection and febrication only, complete all as per specified and as directed by Engineer-in-charge.
33S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge.
34M&L for 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed by Engineer-in-charge.
35M&L for 50mm thick second class hard wood boarding in any situation and in any position, planed both sides fixed with nails, complete all as specified and as directed by Engineer-in-charge.
36M&L for second class hard wood plain fillets in square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc. 6sqcm but not exc.13sqcm, complete all as specified and as directed by Engineer-in-charge.
37M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius inhalf brick thick walls built and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
38M&L for Rendering 10mm thick in cement morter 1:6 on fair faces of brick work or concrete surfaces/ one side of lathing, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
39M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 on other than fair faces Brick Walls/Concrete Surfaces/ other side of lathing, mixed with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed byEngineer-in-charge. NOTE: WPC shall be Measured and Paid as ‘Supply only’ under relevant Item.
40Supply only Integral waterproofing compound, complete all as specified and as directed by Engineer-in-charge.
41M&L for providing 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
42M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
43M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
44M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
45All as per Item No. 44 here-in-above, but area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, complete all as per specified and as directed by Engineer-in-charge.
46M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in vertical surface (like skirting, dado, etc.), over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
47M&L for providing Glazed ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 300x 450x 7 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
48M&L for Forming Construction (Dummy) joints 30mm deep x 10mm wide filled with sealing compound Grade "A", complete all as specified and as directed by Engineer-in-charge.
49M&L for 20mm thick Granite work (of any type, table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as per specified and as directed by Engineer-in-charge.
50S&F of Pressed steel frames for doors of size 105x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed by Engineer-in-charge.
51S&F of Pressed steel frames for doors of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed by Engineer-in-charge.
52S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge.
53S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement; complete all as specified and as directed by Engineer-in-charge.
54S&F of 30mm thick factory made second class hard wood Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides; complete all as specified and as directed by Engineer-in-charge.
55S&F of 30mm thick factory made second class hard wood Glazed and skeleton shutters, divided into squares and prepared to receive glass, gauze, etc. (without sash bars) with plain, chamfered or rounded, mitred and rebated sash bars, any numbers; complete all as specified and as directed by Engineer-in-charge.
56S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars but with necessary arrangements for fixing wiremesh, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
57S&F of Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
58S&F of Steel ventilator with top hung shutter including hinges, steel handle, peg stay, glazing bars, complete all as specified and as directed by Engineer-in-charge.
59S&F of 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
60S&F of 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
61S&F of Galvanised mild steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
62M&L for providing in patches not exc. 0.50Sqm GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
63S&F of 100 mm long Butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed by Engineer-in-charge.
64S&F of 150 mm long Extruded aluminium alloy handles, cast type, anodised, complete all as specified and as directed by Engineer-in-charge.
65S&F of 150 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
66S&F of 250 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and as directed by Engineer-in-charge.
67S&F of 140 mm Overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and rubber end, fixed in floor, complete all as specified and as directed by Engineer-in-charge.
68S&F of Mild steel 300mm long, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-in-charge.
69S&F in-repair of 20 mm dia mild steel, chromium plated curtain rail with fixing brackets, stops, rollers etc., complete all as specified and as directed by Engineer-in-charge.
70M&L for Providing Cement Concrete 1:3:6, type C-1 (20mm graded aggregate) as in Coping, edging, lintels upto 1.5m clear span, cills, steps; hold-fast block, filling in pressed steel frames, seismic and other similar bands etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed by Engineer-in-charge.
71S&F of exposed powder coated GI snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with suspended hangers of 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with and including Supply & fixing/ laying/ inserting of pre-painted (white) 4mm thick designer classic E-boards (595x595 mm) to GI frame work, complete all as specified and as directed by Engineer-in-charge.
72S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
73S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
74M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 1.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
75M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant primer, complete all as specified and as directed by Engineer-in-charge.
76M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat ofred oxide primer, complete all as specified and as directed by Engineer-in-charge.
77M&L for preparation of new or previously un-treated wooden Surfaces of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat ofpink primer, complete all as specified and as directed by Engineer-in-charge.
78M&L for preparation of new or previously un-treated woodenSurfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat ofpink primer, complete all as specified and as directed by Engineer-in-charge.
79M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of Creosote oil, complete all as specified and as directed by Engineer-in-charge.
80M&L for Complete removal of existing treatment of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 1.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
81M&L for complete removal of existing treatment of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant primer, complete all as specified and as directed by Engineer-in-charge.
82M&L for preparation of old painted steel/ iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of Synthetic enamel paint (1st quality) of any tint, complete all as specified and as directed by Engineer-in-charge.
83S&F of bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed by Engineer-in-charge.
84S&F of 15mm dia galvanised steel tubes, "medium grade", with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
85S&F of 20mm dia galvanised steel tubes, "medium grade", with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
86S&F of Wash down water closet (Pedestal pattern) pan and S/P trap of 540x375x415mm with and including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or anodised aluminium hinging device including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., complete all as specified and as directed by Engineer-in-charge.
87S&F of Vitreous China wash basin wall hung type with full padestal, white, size 200x550x400mm including fixed to wall with CP brass screws, fixing of 15mm dia 450mm long PVC connection pipe and 32mm dia 900mm long PVC Flexible waste pipe with and including 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.; complete all as specified and as directed by Engineer-in-charge.
88S&F of 10 litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm dia, with and including making necessary connections, complete all as specified and as directed by Engineer-in-charge.
89S&F in-repair of sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed by Engineer-in-charge.
90S&F of 15 mm dia fancy type Brass CP telephonic wall mixer with hand shower (3-in-1) for mixing hot & cold water, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge.
91S&F of 15 mm dia fancy type Brass CP basin mixer without pop up waste for mixing hot & cold water, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge.
92S&F of Brass chromium plated shower rose of 125mm dia of rose, fixing to existing pipe or union of 15 mm dia, complete all as specified and as directed by Engineer-in-charge.
93S&F of 15 mm dia fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge.
94S&F of 15 mm dia fancy type, chromium plated Stop valves/ Angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engineer-in-charge.
95S&F for 32mm dia High density poly ethylene pipes (HDPE) of pressure rating 6 kg/ cm2fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
96S&F of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/ laid in trenches, complete all as specified and as directed by Engineer-in-charge.
97S&F of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/ laid in trenches, complete all as specified and as directed by Engineer-in-charge.
98S&F of 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-in-charge.
99S&F of 110mm dia PVC (SWR) vent cowl, complete all as specified and as directed by Engineer-in-charge.
100S&F of 110mm dia PVC (SWR) bends any radius, complete all as specified and as directed by Engineer-in-charge.
101S&F of PVC connection pipe 15mm dia with PTMT nuts of length 450mm, complete all as specified and as directed by Engineer-in-charge.
102Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets, tube light fittings etc, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge.
103Taking down carefully old unserviceable main switch and DB"s with and including MCB"s and wooden board, etc, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge.
104Taking down sub-main wiring, service connection cable of any description with all fittings (bricks, GI pipe, etc.), removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge.
105Taking down old unserviceable earthing of any description, complete all as specified and as directed by Engineer-in-charge.
106M&L for disconnecting and taking down ceiling fan/ exhaust fan of any sweep, sealing cable end, dismantling blades and keep fan and blades in safe custody and re-fixing the same into existing position, complete all as specified and as directed by Engineer-in-charge.
107M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push,complete all as per specified and as directed by Engineer-in-Charge.
108All as per Item No. 107 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge.
109All as per Item No. 107 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
110All as per Item No. 107 here-in-above, but for One 3 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
111S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
112S&F of Socket outlet 3 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
113S&F of Switch socket combination 2 in 1, 5/6 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
114S&F of Switch socket combination 2 in 1, 3/5Pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
115S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
116S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
117S&F of Bell push, flush type, 5/6 amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
118S&F of Bell Buzzer/ Ding Dong, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
119S&F of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
120S&F of LED Bulb of 07 Watt, B-22 base, complete all as specified and as directed by Engineer-in-charge.
121S&F ofSheet Metal Enclosure MCB DB TPN, 4 way 415 volt, with 200 amps rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge.
122S&F ofSheet Metal Enclosure MCB DB SPN, 4 way 415 volt, with 200 amps rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge.
123S&F ofSheet Metal Enclosure MCB DB SPN, 8 way 415 volt, with 200 amps rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge.
124S&F ofSheet Metal Enclosure MCB DB SPN, 12 way 415 volt, with 200 amps rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge.
125S&F of MCB Triple Pole & Neutral (TPN), "C" Curve, 40-100 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
126S&F of MCB Single Pole & Neutral (SPN), "C" Curve, 32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
127S&F of MCB Single Pole (SP), "C" Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
128S&F of surface and wall mounted LED tube light fitting 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
129S&F of surface and wall mounted LED light fitting mirror type 1x 10W, (2 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
130S&F of energy saving ultra modern environmental friendly sleek LED Bulk headfitting 10 watt, IP65 protection with driver, holders & LED lamp including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
131S&F of exhaust fan, sturdy engineering plastic body, AC single Phase, 230V of size 250m sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
132S&F of PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep, complete all as specified and as directed by Engineer-in-charge.
133S&F of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 16.0 Sqmm section, complete all as specified and as directed by engineer-in-charge.
134Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 16 Sqmm 4 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
135S&F of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board and taking down the existing old unserviceable wiring, complete all as specified and as directed. NOTE :- (a)Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b)Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c)Sub-main Wiring will be measured PVC Casing capping only.Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
136M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade) andchamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:-(i)item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire.
137S&F in-repairof bracket suitable for LED Street light fitting/ house service bracket made out of 25mm bore (Dia) light grade GI pipe of 1.2m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 50x6mm) forfixing of building security/ street light fitting as per existing with and including applying two coats of synthetic enamel paints to mild steel surfaces, complete all as specified and as directed by Engineer-in- Charge.
138S&F in-repair Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 20 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements, complete all as specified and as directed by Engineer-in-charge.
139Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.