Tender For Additional/Alternator To Building No. T-165 (Satluj) At Air Force Station Pathankot., pathankot-Punjab

Military Engineer Services-MES has published Tender For Additional/Alternator To Building No. T-165 (Satluj) At Air Force Station Pathankot.. Submission Date for this Tender is 01-02-2024. Building Repair Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41713034
Corrigendum : Tender For Additional/Alternator To Building No. T-165 (Satluj) At Air Force Station Pathankot.
Open Tender
Indian
Punjab
pathankot
01-02-2024

Tender Details

Tender For Additional/Alternator To Building No. T-165 (Satluj) At Air Force Station Pathankot.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 32000.0 /-
Tender Value
INR 16 Lakhs /-

BOQ Items

Name of Work : ADDN/ALTN TO BLDG NO T-165 (SATLUJ) AT AIR FORCE STATION PATHANKOT
Sl. No. Item Description
1Taking down cement plaster on brickor stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc completeall as specified and directed by Engineer-in-charge.
2Material and Labour for complete removal of existing treatment (including wall. papers or any other similar treatment ) from walls completeall as specified and directed by Engineer-in-charge.
3Material and Labour 10 mm thick rendering in cement mortar (1:6) on brick or concrete surfaces and finished even and smooth without using extra cement completeall as specified and directed by Engineer-in-charge.
4Material and Labour 15 mm thick rendering in two layers (5 mm thick in CM 1:4 over 10 mm thick in cement mortar 1:6) mixing with WPC on top layer @ 200 ml/ bag of cement on brick or concrete surfaces and finished even and smooth without using extra cement completeall as specified and directed by Engineer-in-charge. (WPC shall be measured and paid separately).
5Supply only liquid water proofing compound completeall as specified and directed by Engineer-in-charge.
6Material and Labour for rendering or plastering work 10mm thick in CM 1:3 in fascia or edging of Chajjas, ceiling and roof projections etc, incl roughening old concrete surface and making the line in true shape and finishing the surface without using extra cement completeall as specified and directed by Engineer-in-charge.
7Material and Labourfor preparation of surfaces of wall and applying 3mm thick wall care putty and making the surface perfectly smooth using necessary tools etc completeall as specified and directed by Engineer-in-charge.
8Material and Labour for applying two coats of plastic emulsion paint on surfaces of wall using auto paint roller completeall as specified and directed by Engineer-in-charge.
9Dismantling of floor, hearth or wall tilingincluding cement mortar bedding (but not backing ) removingserviceable tiles to storeand rubbish off the premises completeall as specified and directed by Engineer-in-charge.
10Material and Labour for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exc. 0.06 sqm and n. exc. 0.38 sqmin floorsetc set and jointed(joint free) in neat cement slurry and pointed in coloured cement. over and incl screed bed or bedding layers of mortars 15 mm thick in CM 1:6 of pattern and shade as approved by GE for layingfloor finishes completeall as specified and directed by Engineer-in-charge.
11Material and Labour for vitrified glossy bathroom wall tiles of size 600mm x 1200mm in differentcolour combination or any shade as approved by GE, on vertical surfaces such as skirting, dadosetc set and jointed using proper adhesive chemical mixture and proper levelling incl cutting for sanitary fittings completeall as specified and directed by Engineer-in-charge.
12Material and Labour for glazed ceramic coloured in differentcolour combination as approved by GE ,450x350x7mm thick on vertical surfaces such as skirting, dados and riser to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl rendering 10mm thick in CM (1:4) on brick or concrete surface completeall as specified and directed by Engineer-in-charge.
13Material and Labour 75 mm thick P.C.C 1:4:8 type D2 (using 40 mm graded aggregate) as in sub base of flooring completeall as specified and directed by Engineer-in-charge.
14Material and Labour for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in benching, coping & hanuching etc completeall as specified and directed by Engineer-in-charge.
15Material and Labour for non skid heavy duty designercoloured tiles as in floor for parking or other open area like flag post etc of10 to 12 mm thick area of each tile exc. 0.11 sqm and n. exc. 0.18 sqmin floorsetc of pattern as approved by GE, set and jointed(joint free) in neat cement slurry and pointed in coloured cement. over and incl screed bed or bedding layers of mortars 15 mm thick in CM 1:6 for layingfloor finishes completeall as specified and directed by Engineer-in-charge.
16Material and Labour Marble work like Udaipur green 16mm to 18mm thick (table rubbed and polished)as in cooking plateforms, treads, riser or landing of stair hall, window cill of floors and like over cement mortar (1:4) screed bed 20mm thick including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of other than white and black incl cutting of 25 mm dia hole for gas pipe and incl rounding to edges incl taking down existing stone slab and similar completeall as specified and directed by Engineer-in-charge.
17Material and Labour Granite work 16mm to 18mm thick (table rubbed and polished)as in platforms, counter for Wash hand basin, treads, riser or landing of stair hall, window cill of floors and like over cement mortar (1:4) screed bed 20mm thick including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of other than white and black incl cutting of 25 mm dia hole for gas pipe and incl rounding to edges incl taking down existing stone slab and similar completeall as specified and directed by Engineer-in-charge.
18Cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection 75mm thick finished even and fair incl making joints at every 2.5m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and completeall as specified and directed by Engineer-in-charge.
19Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc. 1.5 Sqm each and removing from site completeall as specified and directed by Engineer-in-charge.
20Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n exc. 4.00 Sqm each and removing from site completeall as specified and directed by Engineer-in-charge.
21Supply and Fixing factory made single extruded WPC solid UV printed decorative type flush door shutters of size 30mm thick comprising of virgin polymer of K value 58-60 ( suspension grade), calcium carbonate and natural fibres ( wood powder/rice husk/wheat husk) and non toxic additives ( maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N ( face) & 900N ( edge), minimum compressive strength 50N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardnat . WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary fulll body threaded star headed counter sunk SS screws , completeall as specified and directed by Engineer-in-charge.
22Supply and Fixing 300mm long Stainless steel sliding door bolt with hasp and staple ( bolt type) and fixing clips of sheet,and fixing bolts and sliding boltsand fixed completeall as specified and directed by Engineer-in-charge.
23Supply and Fixing for Stainless steel Butt hinges,exc125 mm long, ISI marked completeall as specified and directed by Engineer-in-charge.
24Supply and Fixing stainless steel tower bolt150 mm size completeall as specified and directed by Engineer-in-charge.
25Supply and Fixing 150 mm long stainless steel handels completeall as specified and directed by Engineer-in-charge.
26Supply and Fixing heavy duty stainless steel magnetic door stopper4 inches long completeall as specified and directed by Engineer-in-charge.
27Supply and Fixing factory made single extruded WPC solid UV printeddecorative type flush door shutters of size 35mm thick comprising of virgin polymer of K value 58-60 ( suspension grade), calcium carbonate and natural fibres ( wood powder/rice husk/wheat husk) and non toxic additives ( maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N ( face) & 900N ( edge), minimum compressive strength 50N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardnat . WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary fulll body threaded star headed counter sunk SS screws , completeall as specified and directed by Engineer-in-charge.
28Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made completeall as specified and directed by Engineer-in-charge.
29Supply and fixing factory made uPVC coloured Sliding window of area not exceeding 2 sqm each Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drillin of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories incl fully selected quality tinted glass 5.5mm thick with rubber gasket completeall as specified and directed by Engineer-in-charge. Note : The quoted rates shall includes all other connected accessories including sheet glass and wire mesh.
30Supply and Fixing Box type Steel windows with tubular frame factory made with double shutter (wire gauged shutter & glass glazed shutter ) of size 79mm x 39mm, 16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3 mm flat iron incl projecting type hinges, steel handle, steel peg stay dovetailed or welded , 4 Nostower bolts 100mm long ,10mm square bar grills @75mm c/c welded to frame, incl painting two coats with synthetic enamel paint over a coat of primer, fixing of 3mm thick frosted glass panes and stainless steel wire gauge with putty and pins taking down existing window/ventilator on any floor completeall as specified and directed by Engineer-in-charge and shown on drg no CEPZ/TD-245/01 & and 246/02 sheet 1/2 & 2/2.
31Supply and fixing factory made 25mm thick solid WPC(wood particle composit) sheet one side prelam sheet (of pattern as approved by GE)and other side wood nature colour for cupboard shutter of density 600 kg /Cbm bent 90°incl 100% termite/water proof, fire rertradent, Eco friendly, and finish at all edges at level for making edges lippingusing binding tape etc Complete as per direction of Engr-in-charge, Manufacture specification.
32Supply and fixing in repair factory made 18/19 mm thick solid WPC(wood particle composit) without prelam sheet having both side wood nature colour for cupboard partitions/slabs of density 600 kg /Cbm bent 90° incl 100% termite/water proof, fire rertradent, Eco friendly, completeall as specified and directed by Engineer-in-charge. Manufacture specification.
33Supply and fixing factory made 5mm thick PVC sheet white colour for kitchen cabinet/cupboard of density 600 kg /Cbm bent 90° completeall as specified and directed by Engineer-in-charge.
34Material and Labour for 0.80 mm thick PVC edge binding tape around the 18 to 20 mm thick PVC shutter edge colour as directed, completeall as specified and directed by Engineer-in-charge.
35Supply and Fixing 200 mm long fancy type stainless steel handelsfor shutterscompleteall as specified and directed by Engineer-in-charge.
36Supply and Fixing forcontinuous (piano) hinges, mild steel, bright finishwidth of flaps (when open ) 40 mm completeall as specified and directed by Engineer-in-charge.
37Supply and Fixing for 100mm size hasp and staple,stainless steelsafety type, fixed with screws completeall as specified and directed by Engineer-in-charge.
38Supply and Fixing for 50 mm dia polished hardwood knobs fixed with screws completeall as specified and directed by Engineer-in-charge.
39Supply and Fixing for high quality Magnet ball catcher for cupboard shutter, completeall as specified and directed by Engineer-in-charge.
40Supply and Fixing for stainless steel plain basket of size 17"" x 20"" x 6"" complete completeall as specified and directed by Engineer-in-charge.
41Supply and Fixing for stainless steel partition of size 17"" x 20"" x 6"" completeall as specified and directed by Engineer-in-charge.
42Supply and Fixing for stainless steel cutlery of size 17"" x 20"" x 6"" completeall as specified and directed by Engineer-in-charge.
43Supply and Fixing for stainless steel grain troly with stand of size 21" x 17" x 10" completeall as specified and directed by Engineer-in-charge.
44Supply and Fixing for stainless steel cup & soucer of size 17" x 20" x 4" completeall as specified and directed by Engineer-in-charge.
45Supply and Fixing for stainless steel plate basket of size 17"" x 20"" x 6"" completeall as specified and directed by Engineer-in-charge.
46Supply and Fixing for 20"" long telephonic slider to facilitate drawer slide of steel ball bearing fixed with steel screws completeall as specified and directed by Engineer-in-charge.
47Supply and Fixing for Auto hinges for cabinet case completeall as specified and directed by Engineer-in-charge.
48Supply and Fixing in repair inArt western white viterous china rimless wall hung WC of size 380 x 525 x 350mm with single peice slim concealed cistern of 6/3 Ltrs including floor mounted frame European water closet with CP bolts, nutsC.I. chair or other hanging arrangements with UF soft close seat cover , Bakelite/polypropylene seat and cover with CP hinges & rubber buffers, CP brass screws , trap,washer, CP health faucet 1200mm longand 8mm dia, jet etc with all accessories incl flush plate of chrome of size and pattern completeall as specified and directed by Engineer-in-charge.
49Supply and Fixingin repairs decorative shape type table top Vitreous china wash basin, white of,size 495mm x 395mm x 150mm mmincludingCP waste coupling full thread of suitable sie of wash basin and waste pipei ncl fixing of central hole mixer all as spd and directed. Note : fixing of wash basin on granite/any type of surfacewith adhesive or any type of material deemed to be included in rate quoted by contractor completeall as specified and directed by Engineer-in-charge.
50Supply and Fixing in repair for Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size not less than 400mm x 350mm x 180mmand including swan neck CP mixture and necessary fittings for mixing hot and cold water completeall as specified and directed by Engineer-in-charge.
51Supply and Fixingfancy typelong body Bib taps for 15 mm bore pipe, cast copper alloychromium plated completeall as specified and directed by Engineer-in-charge.
52Supply and Fixing in repair fancy type angular Stop cock15mm bore pipe ,CP cast copper alloy completeall as specified and directed by Engineer-in-charge.
53Supply and Fixing in repair CP 3-in-1 wall mixture with telephonic shower for 15 mm bore pipe, cast copper alloychromium platedcompleteall as specified and directed by Engineer-in-charge.
54Supply only chromium plated brass central hole single lever WHB Mixture for table top wash basin 15 mm bore for mixing hot and cold water with 450long braided house 20 cartriage size screwed down, high pressure screwed for iron pipe completeall as specified and directed by Engineer-in-charge.
55Supply and fixing fancy type stainless steel shower rose with armof pattern and size as approved by GE completeall as specified and directed by Engineer-in-charge.
56Supply and Fixing 15 mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling completeall as specified and directed by Engineer-in-charge.
57Supply and Fixing in repair PVC connections 15mm size with PTMT nuts of length 450mm completeall as specified and directed by Engineer-in-charge.
58Supply and Fixing in repair Stop valve concealed type cast copper alloy (ISI Markd) fancy type, chromium plated with long shank and cup screwed down high pressure with capstan head screwed both ends for iron pipe 15mm bore dia completeall as specified and directed by Engineer-in-charge.
59Supply and Fixing in repairs CP soap dishfixed to walls with chromium plated (CP) brass screws completeall as specified and directed by Engineer-in-charge.
60Fixing only in repairs old sanitary fittings incl. WC, Wash hand basin, wall Mixtures/centerhole mixtures of any type, Stop vaives, shower rose, bib taps, towel rails,glass corner etc into same or other opening incl necessary stainless steel fittings completeall as specified and directed by Engineer-in-charge.
61Demolition of brickwork or stone boulder masonary built in Cement mortar or cement lime mortar incl all quoins, arches, pillars, etccompleteall as specified and directed by Engineer-in-charge.
62Excavation of trenches n.exc 1.5m wide and n.ex 1.5m in depth for foundation etc or for shafts , wells cesspits manholes , pier holes etc n.ex 10sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete all as specified.
63Material and Labour for brick work with sub class "B" brick st or curved on plan exceeding 6 mtr mean radius and built in cm 1:4 etc completeall as specified and directed by Engineer-in-charge.
64Material and Labour for complete Demolition of RCC as inslab/Column/beam and similar suspended works in any positionetc complete including cutting off exposed reinforcement bars and making good the exposed surface with cement work , plaster and paint andcomplete all as specified and directed.
65Material and Labour for dismentelling wall and ceiling board of any thickness including cover fillets complete all as specified and directed.
66Material and Labour for fixing black solar control film reflective typefilm on Glass of alumunium doors completeall as specified and directed by Engineer-in-charge.
67Material and Labour for fixing frostedsheet glass 5.5mm thick exc0.5 Sqm as in al doors including all its fixtures complete all as specified and directed.
68Material and Labour for powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors with one or more rebates including jointing cleat for fixing complete all as specified and directed.
69Supply and Fixing for powder coated Anodised aluminium door shutters, (powder coating of any color of thickness not less than 50 micron) aluminium section of thickness not less than 1.2mm including necessary joining cleats, glazing clips, ruber neoprene packing, handles in, hinges, anodised aluminum snap beading screws etc. ofwhich provision is to be made for sliding of door shutter on guide rail and roller completeall as specified and directed by Engineer-in-charge. Note : minimum thickness of aluminum section shall be not less than 1.2mm thick.
70Material and Labour for termite treatment along the external/internal wall below concrete or masonryapron or tiles using chemical emulsion@2.25litresperlinearmetreincluding drilling and plugging holes etc. in apron completeall as specified and directed by Engineer-in-charge.
71Material and labour for RCC (1:1 ½:3) using 20mm graded stone aggregate as in foundation of column, pillar and post etc complete all as specified and directed.
72Material and labour for MS TMT bars 8-10 mm dia cut to length, bend to shape including cranking, bending and binding with MS wire not less than 0.9mm dia
73Form work to sides of column, posts, pilllars, columns and stanchionsrough finished surfaces of finished concrete Square, rectangular or polygonal complete all as required at site or directed by Engr-in- Charge.
74Stainless steel plates (plain or chequred), square cut or notched (ordinary and counter sunk) forming holes, without any attachment, including necessary running weilding for connection of parts to rafters and purlinsFe 410-W (Gde-E-250) quality-A complete all as specified and directed by Engineer-in-Charge.
75Supply and fixing Mild steel tubes for structural purpose as in posts, purlins, rafters and the like cut to length as required on site including running welding to the frame complete all as specified and directed by Engineer-in-Charge.
76Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long dia of neck in MM exc 20mm but nexc 25mm, complete all as specified and directed.
77Material and labour for designing, providing fabricated, assembling and erection of prestressed special arch membrane roofing structure with MS tubular framework (as per in structural steel) in desired profile as per conceptual drawing as per manufacturing and supplyingstandards by serge/Mahler verseidag/Sieen or etc, The membrane should confirm to the manufacturing and supplying standards being pre-pre-stretched in both weft and weft direction and anufacturing to perform best dynamic stability in both ward and ward direction with approved installers and manufacture for arch roofing with at least two executed job reference in this connection. The fabric must be of HT polyster yarns 110D coated with uniform 230 micron PVC coating over the ployster yard. The top coat over the PVC must be of height connentration with easy clean availability and superior while pigmentation of membrane. The dimensional stability of fabric should be measured as per elongation test of of 24 Hrs-10 DAN/5 cm which should confirm <1% (EN15977) and residual elongation should confirm <0.4% (EN15977) ensuring dimensional stability in both weft and ward direction, minimum weight should be 900-950 gm/sqm (EN ISO 22869-2) 4200/4000 N/50mm (EN ISI 1421) and tear strength of 550/500 N (DIN53363) and with a guarantee of 10 yrs from the manufacturer. Pole to pole spacing of the fabric should be required for the porch. The chargeable area will be fabric surface area including the measurement of the fitting used for fixing on foundation will be provided by the supplier and the foundation if any shall be made by the contractor. Foundation design drawing considering the wind pressure shall be provided by the supplier/contractor to GE for its approval. Minimum design criteria of the structure: Circular column: 100mm dia. Rafter/Purlin:75mm dia. Size of base plate : 200x200 mm, stainless steel plate thickness of 20mm with 20mm dia nut bolt, GI wire rope for fabric, deco primer and pain. 850 GSM while fabric, pole to pole distance min 2.5 m, clear height 2.5 m from FFL, excavation pit size 1m x1mx 1.2m, lean concrete 150 mm thick 1:4:8 type D2 for col footing 8-10mm dia TMT bar in footing and base column at 100mm centre to centre and also refer IS: 456 considering wind pressure, structural design, foundation RCC 1: 1 ½: 3 complete all as specified and directed by Engineer-in-Charge. Note: 1. Payment for structure steel, reinforcement steel including base plate, nut bolts and RCC shall be measured and paid separately under respective items
78Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. completeall as specified and directed by Engineer-in-charge.
79M & L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with multistranded copper conductor ISI marked drawn through in concealed PVC/Steel conduit and accessories,modular white cover plate with frame and metal flush box for mounting of switches, socket regulator etc including 1.5 Sqmm PVC insulated unsheathed cable multistranded copper conductor and connecting to earth dolly for light, Fan, Plug and bell and making goodthe distributed surfacess completely matched and finished with existing surfacessall as directed and specified by Engr-in-charge. (a) One light/fan pointcontrolled by one switch
80(b) One 3 pin switch socket outlet point 5 Amps on independent board.
81(c) One 3 pin switch socket outlet point 5 Amps on same board with other switch.
82All as perabove item but with 2.5 Sqmm cable for 15 Amp switch socket out let point on independent board including 1.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor completeall as specified and directed by Engineer-in-charge.
83Supply and fix Shynora modular switch 1 way 6 Amps 1 module 230 Volts AC completeall as specified and directed by Engineer-in-charge.
84Supply and fix Shynora modular socket outlet 6 Amps 2/3 pin combined 2 module 230 Volts AC completeall as specified and directed by Engineer-in-charge.
85Supply and fix Shynora modular socket outlet 6/16 Amps 2/3 pin combined 2 module 230 Volts AC completeall as specified and directed by Engineer-in-charge.
86Supply and fix Shynora modular switch 1 way 16 Amps 1 module 230 Volts AC completeall as specified and directed by Engineer-in-charge.
87Supply and fix Shynora fan regulator 120 Watt -2 Module 230 V, step type completeall as specified and directed by Engineer-in-charge.
88Supply and fix Shynora modular bell push flush type 10 Amps 1 module 230 Volts AC completeall as specified and directed by Engineer-in-charge.
89Supply and fix Shynora call bell multimusic type, single pole, 230 volts AC completeall as specified and directed by Engineer-in-charge.
90S & Fixceiling rose surface backlite 65x50mm 3 terminals completeall as specified and directed by Engineer-in-charge.
91Taking down old and u/s light fittings conventional type from wall surface / ceilling or any position and making good the disturbed surfaces completeall as specified and directed by Engineer-in-charge.
92Supply & fixing7.5 watt wall light flortine LED filament lampcomplete fitting withall fixing arrangement complete including taking down with completeall as specified and directed by Engineer-in-charge.
93Supply and fixing LED light fittingMuzrisis picture light 20 watt 220 V AC decorative type with and LED lamp including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and directed by Engineer-in-charge.
94Supply and fixing LED light fittingMuzrisis laminar wall light 12 watt 220 V AC decorative type with and LED lamp including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and directed by Engineer-in-charge.
95Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completeall as specified and directed by Engineer-in-charge.
96Supply and fixing Square Shape Integral decorative LED bollards with IP 65 degree of protection of capacity 9 Watt LED with all accessories complete errect / fixed / mount properly at directed place with reqd fixing/mounting arrangement and connecting/testing complete all as directed.
97Supply and fix in repl of u/s and broken with new ventilating fresh air fan made of sturdy Engineering plastic complete with louvers shutters , 250 mm sweep, single phase, 230 Volts AC,1200 RPM,, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing completeall as specified and directed by Engineer-in-charge.
98Supply and fixing ceiling fans complete with aerodynamic ABS blades,dimmable & tunableoptionair delivery in its class with 18 poles motor , down rods, electronic regulator and accessories, 230 V, 1250 mm sweep. Min air delivery 280 m3/min CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)Make-Havells/Orient/Usha
99M&L for factory made gate light junction box, single phase, 2 wire, 240 volts, weather proof pole mounted made out of 1.63 mm thick MS sheet of size 250x150x100mm depth,with properly insulated aluminium buses - 02 Nos of 32 Amps rated current cap with holes for connecting of cables, hinged door and locking bolt, handle completeall as specified and directed by Engineer-in-charge.
100Taking down carefully unserviceable DB any type/size disconnecting and making good disturbed surfaces complete all as directed
101Supply and fixing factory made epoxy powder coated distribution board double door VTPN 4 ways vertical type MCCB DB, with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management completeall as specified and directed by Engineer-in-charge.
102Supply and fixing factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed by Engr-in-Charge
103Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size completeall as specified and directed by Engineer-in-charge.
104Supply and fixing MCCB TPN415 Volt C curve 10 KA 63 to 100 Amps capacity ccompleteall as specified and directed by Engineer-in-charge.
105Supply and fixing MCB single pole & neutral 240 volt "C" curve 10 KA 40Amps completeall as specified and directed by Engineer-in-charge.
106Supply and fixing MCB single pole 240 volt C curve 10 KA 5 to 32 Amps capacity all as specified and directed incl taking down old one.
107Taking down old and u/s sub main wiring of 2/3 runs of any sizes from any position including, making good disturbed surface of wall ceiling etccompleteall as specified and directed by Engineer-in-charge.
108M&L for concealed sub main wiring using two single core PVC insulated, unseathed stranded copper conductor cable of size 6.0 Sqmm of voltage rarting upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)completeall as specified and directed by Engineer-in-charge.
109All as per Item above above but sub main wiring using two single core PVC insulated, concealedconduit suitable size ,unseathed FRLS multi stranded copper conductor cable of size 4.0 Sqmm with one run of PVC (green colour) insulated, unsheathed, FRLS multi stranded copper conductor of size 4 Sqmm as earth continuity conductor all as specified and directed.(Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
110Supply and fixingSingle pole and neutral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs.
111Material & labour for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3mm thick busied directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit coverwith handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shora all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 5 of SSR part I 2009 or completeall as specified and directed by Engineer-in-charge.
112Supply & Fixing PVC conduit of size 25 mmdia in wall / surface for existing telephone cable / Lan cable all as directed and specified by Enge in charge.
113Material & Labour for earthing complete with copper earth plate elect rode 600x600x3mm thick buried directly in ground to a depth not less than 3mtr deep below normal ground level with top edge of the earth plate not less than 2.25mtr deep below normal ground level connected to copper strip 20x3mm size as earthing lead by means of soldering/brazing and bolts, nuts, check nuts and washers of brass, GI protection pipe light grade 40mm bore up to test point 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:2:4 type BI, RCC cover with suitable handle, earth pit filled with ground enhancing material i.e. mixture of copper sulphate, magnesia sulphate, graphite power etc mixed in equal quantity all around earth plate up to 150 cm and filledwith vegetable soil above GEM up to ground level earth work in any type of soil all as required and directed including testing on completion. Make of chemical True power/JMV/Powertrac.
114M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as mass concrete for path to bus bar/ panels complete all as specified and directed by EIC.
115Supply , laying, commissioning and testing in replacement of old unservicable, laid in trenches/ducts or passing through pipe ,1100 volt gradeLT UG cable with XLPE insulated armored heavy duty electric cable with strandedaluminium conductor 1100V grade 2 core cross sectional area 16 sqmm laid in trench or passing through pipe including necessary excavation, sand, bricks etc completeall as specified and directed by Engineer-in-charge.
116Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in soft/ loose soil.
117Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete.
118Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point completeall as specified and directed by Engineer-in-charge.
119Material and labour for dry river bed sand filling in trenches for cable cushioning below and abovethe cable complete all as directed by Eng- in -charge.
120M/LSub Class"B"brickcovering protectionto the eletric cablelaiddry flat transversallyalongthe lengthof cableon sandcushioningwith widthequal to lengthof brickccompleteall as specified and directed by Engineer-in-charge.
121Supply and lay GI tube light grade with all fittings and fixed complete to walls and ceilings or laid in floors of size40 mm dia completeall as specified and directed by Engineer-in-charge.
122Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5meterdeep including refilling / with material and, watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified anddirected by Engr-in-Charge.
123M&L for dismentlingand installation ofexisting split type AC 1.5TR/2TR capacity in the location as directed including provision of 45x45x5mm angle iron frame work for mounting of out door unit , fixing of indoor unit with the following :-(i)Fixing of condensor unit with one number compressor and blower / fan housed in cabinet shell of wheather proof factory made unit(ii)Fixing of wall mounted eavporator unit housed in PVC cabinetincluding blower and supply air grill (iii) Fixing of refrigerant piping made out of copper of 3/8" for discharge line and 5/8" for suction line duly insulated for required length as per site.(iv)Preparation of angle iron frame for condemsing unit and painting with two coats of bituminous paint over a coat of primer as per site requirement. (v) PVC pipe for the drain water removal from the room Note : Extra refrigerant pipe will be measured and paid seperately other than retrived against removed one
124Suction and discharge copper tubing 3/8" and 5/8" for split type A?C including provision of insulation on the tubing completeall as specified and directed by Engineer-in-charge.
125supply and Install , electric driven,complete up to Motor Power : 0.9 HPBooster Pressure Pump CM 3-6 of Grundfos inclusive of starter and PCC foundation,CM Pump is supplied with pressure tank for constant water pressure,Head 26-56 mtr. When the pressure drops to the pre-set level, the pump will start-up and when the water consumption drops again, the outlet pressure will rise to a pre-set stop pressure after which the pump will stop including electric and water pipe connection complete job completeall as specified and directed by Engineer-in-charge.
126Supply and fixingwith new wall mounted fan 400 mm sweep, single phase, 230 Volts with regulator, oscilation type complete fixed properly on wall and connecting/testing on load all as directed. Note : Old u/s fan will be deposited to E/M store yard. completeall as specified and directed by Engineer-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail