| 1 | Demolition of brick work built in cement mortar and incl all quins, arches, pillars etc complete all as specified and directed |
| 2 | M&L for brick work with sub class \"B\" bricks old size, straight or curved on plan exc 6M mean radius built in CM 1:6 complete all as specified and directed by the Engineer-in-Charge. |
| 3 | All as per ser item No 2.00 here-in-before but except bricks (by using old serviceable bricks) |
| 4 | Demolition of PCC in ground floors and pavings not exc 15 cm thickness below or above ground level, complete all as specified and as directed. |
| 5 | M&L 75mm thick plain cement concrete 1:3:6 (using 40mm graded aggregate), as in plinth protection/flooring laid in alternate bays, finishing concrete surfaces even and smooth without using extra cement, complete all as specified and as directed. |
| 6 | Demolition of PCC in ground floors and pavings exc 15 cm thickness below or above ground level, complete all as specified and as directed. |
| 7 | M&L forCement concrete type D 2, 1:4:8 (using 40 mm gradedstone aggregate) in sub base of flooring,mass filining and foundation complete all as specified. |
| 8 | M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) 100 mm thick as in flooring/hardstanding laid in alternate bays compelet all as specified and directed |
| 9 | Taking down cement plaster on brick or stone wall etc incl racking out joints hacking for key & scrubbing down with water etc. complete all as specified and directed. |
| 10 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick masonry or concrete walls, chajja, fins, facia etc upto 3 stories height mixed with water proofing compound (ISI mark) @ 200ml per 50kg of cement or as per manufacturer\"s instructions, finished even & smooth without using extra cement complete all as specified & directed.Note:- 1. Water proofing compound shall be measured and paide for separately as supply only.2. Cost of scaffolding for rendering is included in this item. No extra payments shall be paid to contractor against this.3. Rendering will be done in two layer i.e. Ist layer shall be 10-12mm thick & 2nd layer shall be 3-5mm thick. |
| 11 | M & L for rendering 10 mm thick on fair faces of brick wall finished fair & smooth in CM 1:6 complete all as specified and directed. |
| 12 | M & L three coats of white washing on wall of new plastered surface, complete all as specified and directed. |
| 13 | M&L preparation of new plastered surfaces of wall and applying two coats of cement base paint of approved shade/tint with alkali fungal & resistant primer etc complete all as specified and directed. |
| 14 | All as per ser item No 13.00 here-in-before but one coat of cement base paint on old decorated surfaces of wall including preparation complete all as specified and directed.. |
| 15 | All as per ser item No 13.00 here-in-before but one coat of white wash on old surfaces of wall including preparation complete all as specified and directed. |
| 16 | Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) including iron mongery and cutting holes for hold fasts & making good complete all as specified & directed. |
| 17 | S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riverted or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters walk ways railings framework of water tanks and similar work conforming to Fe 290. Gde-E-165 complete all as specified and directed. |
| 18 | S & F factory made 30 mm thick IInd class HW glazed & skeleton shutters open rebated and prepared to receive glass gauge etc. (without sash bars) edges of framing plain chamfered or rounded fitted with cut & mitered beads for security glass/gauge etc. size of members of shutter ,divided into squares with plain chamfered rounded, mitered and rebated sash bars complete all as specified. |
| 19 | M&L two coat synthetic enamel paint over one coat of pink primer on new wooden surface of any description not otherwise described over 10 cm width or girth complete all as specified and directed... |
| 20 | S&F 75mm stainless steel butt hinges medium weight complete all as specified and directed. |
| 21 | S&F aluminum anodized barrel tower bolts of extruded section andfixed 100 mm long complete all as specified and directed by Engr-in-Charge. |
| 22 | S&F aluminum handles cast type anodized 100 mm size complete all as specified and directed by Engr-in-Charge. |
| 23 | Supply and fixing plain Sheet Glass3.0 mm thick, Square or Rectagular, area not exc. 0.50 Sqm in Each Pane and fixing to Aluminium Window, Ventilator Shutters, complete all as specified and as directed. |
| 24 | M&L for1.00mm thick plain, black, mild steel sheeting, in ridges,hips, gates, valley gutters,drip and straight flashings (length and girth as fixed)etc complete all as specified. |
| 25 | M&Lfor mild steel work wire netting of galvanised steel wire, 1.40mm dia and 25 mm dia aparature etc complete all as specified. |
| 26 | Repair / maintenance of existing gear operated type including repair of gear box rolling shutters of any size / description by repairing the small repairable parts of rolling shutters such as hood covers, guide channels, lock plate, riveting, bolting et including greasing the rolling shutters and making it functional to the entire satisfaction of Engineer -In-Charge. |
| 27 | Taking down rolling shutters of any description and any size for replacement of the unserviceable parts and greasing the shutters complete all as specified and directed.Note :- The rate includes all small necessary allied works such as welding/ bolting/ riveting / punching/ sealing and like and fixing charges of the below mentioned items |
| 28 | (a)Supply only mild steel S.W.G spring for rolling shutters of wt not less than 2.50 Kg each |
| 29 | (b)Supply only mild steel S.W.G spring for rolling shutters of wt not less than 5.50 Kg each. |
| 30 | (c ) Supply only 40/50mm dia mild steel medium weight pipe as in anchorage rods in single lengths. |
| 31 | (d)Supply only 1.00 mm thick plain black sheet as in hood over and bent to required shape. |
| 32 | (e ) Supply only complete gear box with mild steel pipe of dia not less than 25mm |
| 33 | S&F Steel rolling shutters having thickness of laths 1.25 mm , with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed. |
| 34 | S&F Steel rolling shutters having thickness of laths 1.25 mm , with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete:gear operated type with chain wheel and hand chain complete all as specified and directed. |
| 35 | S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 36 | S&F Ball bearing for rolling shutters complete all as specified and directed. |
| 37 | Dismantling old plain or corrugated Asbestos cement/ Steel sheeting in roof coverings etc and remove materials from site of work complete all as directed. |
| 38 | M&L for Pre-painted galvalume alu. Zinc coating GI based corrugated steel sheet 0.50 mm thick (total coated thickness) of any colour having tensile strength 550 M pa minimum yield strength as in roof covering fixed using hot dip galvanized self drilling and selftapping screws neoprene and EPDM washers. (Note : minimum, yield strength 550 Mpa with hot dip alloy of 55% Aluminium, 43.5 %zinc, 1.5% Silicon and finished with resin coat on both surfaces) complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L for Pre-painted galvalume alu. Zinc coating GI based Plain steel sheet 0.50 mm thick (total coated thickness) of any colour having tensile strength 550 M pa minimum yield strength as in ridges of roof covering fixed using hot dip galvanized self drilling and selftapping screws neoprene and EPDM washers. (Note : minimum, yield strength 550 Mpa with hot dip alloy of 55% Aluminium, 43.5 %zinc, 1.5% Silicon and finished with resin coat on both surfaces) complete all as specified and directed by Engr-in-Charge. |
| 40 | Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in Concrete, brick work, masonry, etc. including taking out embedded portion and making good disturbed ground, complete all as specified and directed. |
| 41 | Dismantling fencing wire mesh,any type,complete all as specified and directed. |
| 42 | S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, running bars, for chain link fencing including embeding in concrete and similar work conforming to Fe-290 Gde E-165complete all as specified and directed |
| 43 | Supply only MS screw, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exceeding 5cm and not exceeding 10cm long and dia of bolt etc, complete all as specified and directed |
| 44 | Supply only galvanised chain link fencing of size 50 x 50mm aperture and dia of were 4.00mmany size or type as approved by Engr-in -charge etc, complete all as specified and directed |
| 45 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete all as specified and directed |
| 46 | Dismantling structural steel work as in roof trusses, rafters, purlin etc complete all as specified and directed. |
| 47 | S&F mild steel work as in Roof trusses, trussed purlines, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections)including distance pieces, cleats etc, conforming to Fe-290(Gde-E-165)complete all as specified and as directed. |
| 48 | M&L for two coat of synthetic enamel paintover one coat of red oxide primer on new steel surface of any description not other wise described over 10 cm width or girth complete all as specified and directed |
| 49 | M&L for complete removal of existing painting from old steel surfaces and applying two coats of synthetic enamel paint of any description over 10 cm width or girth including preparation of old surfaces complete all as specified and directed. |
| 50 | Repairing of RCC projections chajjas, roofs, facia etc by necessary preparation, scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC and providing cement concrete (1:1.5:3) using 12.5 mm graded crushed stone aggregate including necessary form work and reinforced with chicken wire mesh and rendering incement mortar 1:3 using coarse sand in patches area not exceeding 5 sqm each and thickness of RCC member not exceeding 70mm including applying two coats of finishes as provided to the existing surfaces to match with the existing surfaces in at any height complete all as specified and directed. |
| 51 | Excavation in trenches n exc 1.5 M wide andexc 1.5 M deep but, n exc 3 M deep and getting out in soft/loose soil for shafts, wells, man holes and for sewage lines and foundation etc n exc 10 Sqm on plan all as specified. |
| 52 | Returning, filling inincluding spreading leveling watering and well ramming in layers n exc 25 cm thick all as specifiedand directed by Engineer-in-Charge. |
| 53 | Removing excavated material to a distance exc 500.00m but n exc 1.50 Kmand depositing where directed at a level n exc 1.50m above starting point complete all as specified and directed by the Engineer -in-charge. |
| 54 | Demolition of existing paver block any size ,any pattern complete all as specified and directed |
| 55 | M&L for Moorum in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed |
| 56 | M & L for rendering 15 mm thick on brick or concrete surface in CM 1:4 complete all as specified and directed. |
| 57 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 58 | M& L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surfacecomplete all as specified and directed. |
| 59 | M&L for PCC 1:2:4 type B-2using 40 mm graded aggregate as in holdfasts, mass concrete complete all as specified and directed. |
| 60 | M&L fornon skid ceramic coloued tiles 10 mm thick, area of each tiles n. exc 0.36 sqm in floors, set and pointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed |
| 61 | M&L,for non skid ceramic coloured tiles 10 mm thick, area of each tiles n. exc 0.36 sqm in floors, set and pointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over but, on vertical surfaces over and incld 10 mm thick rendering in CM 1:4complete all as specified and directed |
| 62 | M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as on roof surface/roof kerbs and similar articles with or without plane faces with finishing cement concrete surface even & smooth without using extra cement etc all as specified & directed by Engg-in-charge |
| 63 | M& L for preparation of new plastered surface and applying two coat of weather proof exterior emulsion paint over coat of primer and 1 mm thick wall care putty complete all as specified and directed. |
| 64 | Disconnecting existing LT over heated or burnt cable terminal at existing panel/ board/feeder pillar box etc., cutting out over heated / burnt / unserviceable portion of cable, stretching of cable end of required length from available rings etc. and fixing and connecting the cable in position properly by providing suitable aluminium lugs and GI nuts, bolts & washers etc. including neccessary excavation and earth work for size of cable 16 Sqmm to 95 Sqmm complete all as specified and directed |
| 65 | M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level)with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead 25X4mm strip by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing completeall as specified& directed. |
| 66 | Supplying and fixing earth continuity conductor or main earthing lead 25mmx4mm, GI strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers and saddling, welding at every joint complete all as specified and directed. |
| 67 | Supply, installation, testing & commissioning of distribution LT panelOUTDOOR IP-54 protection as per IS 2147 CPRI apporoved suitable for AC, 3 Phase 4 wire, 415V, 50 Hz having dust and vermin proof MSsheet 1.6mm thick CRCA with suitable size complete painting, PCC etc comprising of the following accessories(a)Bus bar: Electronic high condutive aluminium bus bar of appropirate cross sectional area-04 Nos(b) Voltmeter digital type 0-500 with three phase selector switch -01 Nos.(c)Ammeterdigital square type 0-250A with CT\"s of suitable size andthree phase selector switch-01 Nos.(d)Phase indicating lamps LED type RYB indicator holder with 0-5Amps 01No (03 Set).In coming:-1. MCCB- 125 Amps, 415V, 4 Pole, AC with thermal setting 70% to 100% and 36 KA-01 Nos Out going:-1.MCCB -63 Amps, 3 Pole, AC with thermal setting 70% to 100% and 25 KA-03 No. 2. MCCB -40 Amps, 4 Pole, AC with thermal setting 70% to 100% and 16KA-03 No. |
| 68 | Supply, installation, testing & commissioning of distribution LT panelOUTDOOR IP-54 protection as per IS 2147 CPRI apporoved suitable for AC, 3 Phase 4 wire, 415V, 50 Hz having dust and vermin proof MSsheet 1.6mm thick CRCA with suitable size complete painting, PCC etc comprising of the following accessories(a)Bus bar: Electronic high condutive aluminium bus bar of appropirate cross sectional area-04 Nos(b) Voltmeter digital type 0-500 with three phase selector switch -01 Nos.(c)Ammeterdigital square type 0-250A with CT\"s of suitable size andthree phase selector switch-01 Nos.(d)Phase indicating lamps LED type RYB indicator holder with 0-5Amps 01No (03 Set).In coming:-1. MCCB- 100 Amps, 415V, 4 Pole, AC with thermal setting 70% to 100% and 36 KA-01 Nos Out going:-1.MCCB -63 Amps, 4 Pole, AC with thermal setting 70% to 100% and 16KA-04 No. |
| 69 | Supplying, Laying, jointing and testing XLPELT Cable PVC insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade of 35 Sqmm 3.5 core laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge |
| 70 | Supplying, Laying, jointing and testing XLPELT Cable PVC insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade of 25 Sqmm 3.5 core laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge |
| 71 | Supplying, Laying, jointing and testing XLPELT Cable PVC insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade of 16 Sqmm 4 core laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge |
| 72 | Supplying, Laying, jointing and testing XLPELT Cable PVC insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade of 95 Sqmm 3.5 core laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge |
| 73 | Supplying, Laying, jointing and testing XLPELT Cable PVC insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade of 10 Sqmm 2 core laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge |
| 74 | Disconnecting and taking out LT cable of any size and any description complete all specified and directed |
| 75 | Supplying and fixingHDPE pipe having pressure rating 6kg/cm2 of 25mm dia size laid in trenches complete all as specified and directed |
| 76 | Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable etc.including taking out existing cable protection brick cover etc.complete all as specified and directed |
| 77 | Removing excavated material to a distance exc 500.00m but n exc 50mand depositing where directed at a level n exc 1.50m above starting point complete all as specified and directed by the Engineer -in-charge. |
| 78 | M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.Note: Punned thickness shall be measured and paid. |
| 79 | Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt,laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed. |
| 80 | Taking down carefully existing unserviceable copper/ aluminium point wiring of any description & in any position with and includingpvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators light fittings etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’. |
| 81 | Material and labour for point wiring for one light /fan/Exhaust fan point controlled by one switch with using FRSLH1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduits /Casing caping (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with laminated top sheet of 3 mm thick for housing of switchws, sockets, regulators etc including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. NOTE :-(I) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & caping of suitable size fixed on ceiling surface with using PVC rawl plugs.(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A\".(iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable brass screws and cup washers |
| 82 | All as per srl item No. 76.00 here-in-before but,point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.complete all as specified and directed.. |
| 83 | All as per srl item No. 76.00 here-in-before but but point wiring for one5 pin socket outlet,on same board . |
| 84 | All as per srl item No. 76.00 here-in-before but but One 6 pin socket outlet, 5/15 Amp independent board controlled by one switch with using PVC insulated and unshethed copper stranded conductor of size 2.5 Sqmmcomplete all as specified and directed. |
| 85 | M & L forswitch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as approved |
| 86 | M&L for socket outlet 2 in 1, 5 pin, 6 Amps flush type white ivory finish complete all as specifiedand as approved |
| 87 | S&F switchsocket combination multi purpose, 5 Pin 6 amps, flush typeWith Indicator complete all as specifiedand as approved |
| 88 | M&L for ceiling rose surface Bakelite two to three terminal, 18 x 50 mm complete all as specified. |
| 89 | M&L for switch/socket combination 2 in 1, 3/6 pin 5 & 16 Amps flush type universal with indicator complete all as specified and directed. |
| 90 | S&F step type electronic fan regulator single phase, 230 volt, 100/200 watt (size of PT switch) complete all as specified and directed. |
| 91 | Supply & Fix for decorative slim linear LED tube light fitting 01x20 watt light with co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with all accessories and connecting the same to ceiling rose with using copper conductor 24/0.20 flexible PVC sheathed cable and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified & directed. |
| 92 | Supply and fixing Street/Security light fittings 1X35W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) with and including bracket made of 40 mm GI pipe light grade, clamp,nut-bolt and washers complete all as specified and directed. |
| 93 | Dismaintling & Taking out MCB DBs with all MCB\"s/Isolator & metal clade box any size , any type and capacity |
| 94 | Supply and fixing of sheet metal enclosure Double door for DB’s 12 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed. |
| 95 | Dismaintling & Taking outMCB\"s/Isolator any size , any type and capacity |
| 96 | S&F MCB single pole 6 to 32 Amps, 10 KA ,240 Volts complete all as specified. |
| 97 | S&F MCB Single pole and neutral 40 to 63 Amps, 240 Volts complete all as specified. |
| 98 | M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level)with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing completeall as specified& directed. |