Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SITE DEVELOPMENT [A]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.b) Oridinary Rock |
| 2 | Mechanical carriage (including loading, unloading & stacking) of material (i.e., earth) for dumping to site. For a lead of 5km |
| 3 | Mechanical carriage (including loading, unloading & stacking) of material (i.e., earth) for dumping to site. Beyond 5km (i.e 15 km) |
| 4 | RETAINING WALL [B]Earthwork in excavation in foundation trenches etc. not exceeding 2 meters depth including dressing of bottom and sides of trenches and subsequent filling and compaction in 15cm layers as in column foundations, fence posts, etc. and disposal of all surplus soil as directed within a lead of 30 metres. b) Hard Soil(pick work) |
| 5 | Providing and laying in position cement concrete of specified grade excludingcost of centering and shuttering - All work upto plinth level: a) 1:3:6 (1 cement :3 course sand :6 stone aggregate 20mm nominal size) |
| 6 | Regular coursed rubble masonry with hard stone in foundation upto one storey above and below ground level including curing, etc. complete.a) in cement mortar 1 : 3 ( 1cement : 3 fine sand) |
| 7 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification. a) Gravelly material. |
| 8 | Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete, abutment, wing wall, return wall with 100mm dia PVC pipe extending through the full width of the structure with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification. |
| 9 | Pointing on stone work with cement mortar 1:3(1 cement : 3 fine sand).b) Raised and cut pointing. |
| 10 | STRUCTURE PORITON [C]Earthwork in excavation in foundation trenches or drains etc. (not exceeding 1.5m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.(b) Hard Soil(pick work) |
| 11 | Providing and laying in position cement concrete of specified grade excludingcost of centering and shuttering - All work upto plinth level: (a) 1:4:8(1 cement :3 course sand :6 stone aggregate 20mm nominal size) |
| 12 | Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. “(Note:- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately) (a) All work upto plinth level |
| 13 | (b) All work from plinth level upto floor V level |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :a) Foundations, footings, bases of columns etc. for mass concrete.i) Footing |
| 15 | b)Walls including attached pillasters, buttresses, string courses, etc. |
| 16 | c) Columns, pillars, piers, abutments, posts and struts. |
| 17 | d)Lintels, beams, plinth beams, girders, bressumers and cantilevers, etc. |
| 18 | e) Suspended floors, roofs, landings, shelves and their support, balconies and chajjaj,etc. |
| 19 | f) Staircases (except spiral staircase) excluding landings. |
| 20 | Steel reinforcement for RCC work including straighthening, cutting, bending, placing in position and binding all complete.b) Thermo-Mechanically Treated bars of grade Fe-500 or more. |
| 21 | WALLING BRICK WORK & PLASTERING [D]Half brick masonry with first class brickin superstructure above plinth level upto floor V level.a) in cement mortar 1 : 4(1 cement : 3 coarse sand) |
| 22 | First class brickworkin superstructure above plinth level upto floor V level in: a) in cement mortar 1: 4 ( 1 cement : 3 coarse sand ) |
| 23 | 12mm cement plaster 1 : 4 (1 cement : 3 fine sand). |
| 24 | Extra for providing and mixing water proofing materials in proportion recommended by manufacturer in -.e) 20mm cement plaster 1:3 (1 cement :3 sand) |
| 25 | OPENINGS (DOORS, WINDOWS & VENTILATORS) [E]For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required. (Glazing to be paid for separately)b) Anodised |
| 26 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .b) With glass panes of 5.00 mm thickness. |
| 27 | Providing Ist class local wood dressed in frames of chaukat for doors, windows, clerestory windows fixed in position. |
| 28 | Providing and fixing readymade door (Masonite or equivalent quality) including M.S. butt hinges with necessary screws complete.b) 35mm Readymade Teak Veneer Door |
| 29 | Providing and fixing CP Brass Sliding Door Bolts (aldrops) bright finished with nuts and screws etc. complete.a) 300 x 16 mm |
| 30 | Providing and fixing CP brass tower bolts (socket bolts) bright finished with necessary screws etc. complete.a) 250 mm |
| 31 | Providing and fixing CP brass handles with necessary screws, etc. a) 250 mm complete |
| 32 | Providing and fixing 150 mm bright finished brass floor door stopper with rubber cushion, screws, etc. to suite shutter thickness complete. |
| 33 | Providing and fixing bright finished BrassDoor Closer with necessary screws, etc. complete.a) Hydraulic Type |
| 34 | Providing and fixing prefabricated M.S. equal angle in chaukhat for doors, windows and clerestory windows including fixing with 40 x 5mm M.S holdfast 40cm long at required spacing and applying priming coatwith approved steel primer etc. complete.a)Using 50 x 50 x 5mm M.S. angle. |
| 35 | Providing and fixing steel glazed doors, windows, ventilators of standard rolled steel sections, joints, mitered and welded with 15x3mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm size of 1:3:6 (1 cement : 3 coarse sand : 6 stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots as required.b)Using 5mm thick glass panes. |
| 36 | Providing and fixing 40mm thick panelled door shutter comprising of styles and rails of seasoned teak wood with panels of Duratuffboard 25mm thick as per required architectural designincluding M.S. butt hinges with necessary screws but excluding varnishing/painting etc. |
| 37 | Providing and fixing Curtain Rod with necessary screws & fittings, etc. a)Bright Finishedcomplete. |
| 38 | Providing and fixing Curtain Rope hook with necessary screws , etc. a)Brasscomplete. |
| 39 | FLOORING (FLOORS & STAIRCASE) [F]Providing and ceramic glazed floor tiles of size 300x300mm or more(thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in all colour shades,except white,ivory,grey,fume red brown,laid on 20mm thick cement mortar 1:4(1 cement : 4 course sand) including pointing the joints with white cement and matching pigments etc, complete as per designed colour.b)Matt/Antiscratch |
| 40 | c)Parking Tiles |
| 41 | Providing & laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS:15622,of approved make, in all colours and shades, laid on bed of 20mm thick cement mortar 1 : 4 (1cement:4course sand),including the joints withwhite cement and matching pigments etc.complete.as per design colours.b)Double Charge |
| 42 | Providing and ceramic glazed floor tiles of size 300x300mm or more(thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in all colour shades,except white,ivory,grey,fume red brown,laid on 20mm thick cement mortar 1:4(1 cement : 4 course sand) including pointing the joints with white cement and matching pigments etc, complete as per designed colour.a)Gloss Finish |
| 43 | 40mm thick red oxide flooring under layer of 30mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 wellgraded stone aggregate 12.5mm size) and top layer 10mm thick plaster of cement red oxide mix using 3.5 kg of red oxide of iron per 50kg of cement in mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement red oxide mix of same proportion including cement slurry etc. complete but excluding the cost of nosing of steps etc. |
| 44 | Marble stone flooring with 18mm thick marble stone as per sample of marble approved by Engineer-in-Charge over 20mm(average) thick base of cement mortar 1:4( 1cement :4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : b) Green marble granite polish |
| 45 | Extra for pre finished nosing to treads of steps of marble stone. |
| 46 | Vinyl Flooring With 5-7mm Thick |
| 47 | PAINTING [G]Applying priming coat with ready mixed primer of approved brand and manufacture on plaster surface.a) Ready mix white primer. |
| 48 | Finishing walls withexterior emulsion of required shade on new work (three or more coats) to give an even shade.b) Premium exterior emulsion like weather shield, weathercote etc. |
| 49 | Wall painting with interior emulsion paint of approved brand and manufacture on new work (two or more coats) to give an even shade.b) Premium interior emulsion like Velvet touch Luxol silk etc. |
| 50 | Applying priming coat with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) & Plywood. |
| 51 | French spirit polishing (two or more coats) on new works including a coat of wood filler:(two or more coats). |
| 52 | STEEL WORKS [H]Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of 80cm high in staircase, etc consisting of 75mm for rail and post, 63mm for longitudinal intermediate rail and 25mm of vertical section, spacing 125mm interval and as per approval of Engineer-in-charge. |
| 53 | Steelwork welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.b) In a grating, frames, guard bar, ladders, railings, brackets, gates & similar works. |
| 54 | ROOFING & CEILING [I]Steel work in built up tubular (round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Roof |
| 55 | Providing Trapezoidal Polyester Coated Galvanised Steel Sheets Roofing of any colourof 1.06m width at all levels including fitting and fixing ridging with self drilling , self tapping screws, EPDM washers etc. complete excluding the cost of purlin, rafter and trusses.b)For0.50 mm thick : |
| 56 | Providing 1st class local wood work dressed in frames of sill, upright, batten, post, beams, etc. as structural members fixed in position complete. |
| 57 | Providing and fixing G.I steel frame works for ceiling lining consisting of battens 50x25mm fixed over plugs embedded in wall with necessary screws, etc. complete. |
| 58 | Supplying, fitting and fixing calcium silicate board ceiling with nescessary screws etc. complete excluding frame work of base and beading. (Hilux or equivalent) |
| 59 | Extra for providing and fixing ceiling to curved surfaces in narrow widths . |
| 60 | MISCELLANEOUS WORKS [J]Providing and fixing G.I steel frame works for ceiling lining consisting of battens 50x25mm fixed over plugs embedded in wall with necessary screws, etc. complete.Framework for Acoustical Board |
| 61 | Providing and Fixing Vertical Mototrized Stage Curtain with size 16x30 ft |
| 62 | Providing and fixing Wood Plastic Composite board walling with necessary screws etc. complete.a)With 12mm thick WPC Board |
| 63 | Providing and Fixing 3d Acrylic Glow Sign including screws,nuts etc. complete |
| 64 | Providing and fixing perforated acoustical panel (Ceiling & Wall) of approved qualityincluding fixing to frames with screws etc. complete. (Installation in wood batten system or steel keel system Frame work to be paid separately). |
| 65 | Providing & fixing ACP External wall cladding of approved quality and maketo frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately). |
| 66 | Under Ground Water Tank (50,000 litres capacity)Earthwork in excavation in foundation trenches or drains etc. (not exceeding 1.5m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. (c) Very Hard Soil(Jumper Work) |
| 67 | Providing and laying cement concreteexcluding cost of centering and shuttering in - All work upto foundation & plinth level.b) 1 : 4 : 8 (1 cement : 4 fine sand : 8 stone aggregate 20mm nominal size) |
| 68 | Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. “(Note:- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately) a) All work upto foundation & plinth level. |
| 69 | Walls, columns, pillars, posts and struts upto floor two level or floor two below from the ground floor (as indicated in the drawing). |
| 70 | Steelreinforcement for RCC work including straighthening, cutting, bending, placing in position and binding all complete.f) Thermo Mechanically Treated Bars of grade Fe 500 or more |
| 71 | Centering and shuttering including strutting, propping, etc.and removal of form works in -a) Foundations, footings, bases of columns etc. for mass concrete. |
| 72 | b) Walls including attached pillasters, buttresses, string courses, etc. |
| 73 | e) Suspended floors, roofs, landings, shelves and their support, balconies and chajjaj, etc. |
| 74 | Filling available excavated earth (excluding rock) in trenches, plinth, etc. in layers notexceeding 20 cms in depth,consolidating each layer by ramming and watering and dressing lead upto 50 meters and lift upto 1.50 meters. |
| 75 | Carriage by Mechanical Transport (within a lead of 5 km) b) Earth |
| 76 | 20mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement. |
| 77 | Extra for providing and mixing water proofing chemical (plastocrete or equivalent chemical) in plain and reinforced cement concrete work 1 : 1.5 : 3 , @ 2% by weight of cement. |
| 78 | Applying double coated PIDIFIN-2K on the surface of cement concrete for prevention of water infiltration and dampness in water tanks, basement, terraces, etc. ) @1.85kg per sqm. |
| 79 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) .(f)50mm Nominal Bore |
| 80 | Providing and placing in position electric water pump of approved manufacture including connections to G.I pipes etc. complete with accessories.(b) 750 watts |
| 81 | Providing and fixing G.I. pipe complete with G.I. fitting including trenching and refilling etc. (external work).(d)40mm nominal bore |
| 82 | Septic Tank & Soak pit (3 Nos of 50 users)Earthwork in excavation in foundation trenches or drains etc. (not exceeding 1.5m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.b) Hard Soil(pick work) |
| 83 | Providing and laying in position cement concrete of specified grade excludingcost of centering and shuttering - All work upto plinth level:a) 1:3:6(1 cement :3 course sand :6 stone aggregate 20mm nominal size) |
| 84 | Half brick masonry with first class brickin foundation and plinth in. a) in cement moratar 1:3 ( 1 cement : 3 coarse sand ) |
| 85 | Honey-comb half brick masonry with first class brick in foundation upto one storeyed above and beloww ground level including curing etc. complete. a) in cement mortar 1 :3 |
| 86 | Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. “(Note:- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately) a) All work upto plinth level. |
| 87 | Steel reinforcement for RCC work including straighthening, cutting, bending, placing in position and binding all complete.(b) Thermo-Mechanically Treated bars of grade Fe-500 or more. |
| 88 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :e) Suspended floors, roofs, landings, shelves and their support, balconies and chajjas,etc. |
| 89 | Providing and fixing single equal SWRPVC plain junction of required degree ( T-junction ) a) 110x110x110mm. |
| 90 | Providing and fixing ventilation cowl including jointing with rubber lubricant/ cement solvent complete.a) 110mm SWRPVC vent cowl |
| 91 | 20mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement. |
| 92 | Applying double coated PIDIFIN-2K on the surface of cement concrete for prevention of water infiltration and dampness in water tanks, basement, terraces, etc. ) @1.85kg per sqm. |
| 93 | Drainage SystemEarthwork in excavation in foundation trenches or drains etc. (not exceeding 1.5m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.a) Oridinary Soil |
| 94 | Providing and laying in position reinforced cement concreteexcluding cost of centering and shuttering , finishing and reinforcement in - a)1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20mm nominal size) |
| 95 | Steel reinforcement for RCC work including straighthening, cutting, bending, placing in position and binding all complete.a) Mild steel and Medium Tensile steel bars. |
| 96 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :b) Walls including attached pillasters, buttresses, string courses, etc. |
| 97 | e) Suspended floors, roofs, landings, shelves and their support, balconies and chajjaj,etc. |
| 98 | 15mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 99 | Extra for providing and mixing water proofing chemical (latex or equivalent chemical) @ 2kg per bag of cement in -c) 15mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 100 | Sanitary FittingsProviding and fixing vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :(ii) Pastel |
| 101 | Providing and fixing White vitreous china (Matrix Set -1) WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 102 | Providing and fixing vitreous china Urinal Flat Back Large 59 x 37.5 x 39cm of Parryware/ Hindware/ Cera and equivalent make with flush valve/spray with C.I or R.S brackets standard size of G.I flush pipe and C.P brass spreaders with brass unions and G.I clamps complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required.(i)White |
| 103 | Providing and fixing Health faucet with flexible tube upto 1 metre long and holder of quality and make as approved by Engineer - in - charge. |
| 104 | Providing and fixing White vitreous china wash basin Standard of Parryware/ Hindware/ Cera and equivalent make with R.S. or C.I. brackets, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plugs, 32mm C.P. brass waste of standard pattern, 32mm C.P. brass traps and union complete including painting of fittings and brackets, cutting and making good the walls wherever required.(a)Vitreous China Wash basin size 630x450 mm with single 15 mm C.P. brass pillar taps. (i) White |
| 105 | Providing and fixing vitreous china tall pedestal of Parryware/ Hindware/ Cera and equivalent make for wash basin completely recessed at the back for the reception of pipes and fittings.(i) White |
| 106 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos sheet ground fixed to cleats with C.P. brass screws and washers. |
| 107 | Providing and fixing C.P. brass towel rail with two C.P. brass brackets to wooden cleats with C.P. brass screws.a) 750x20mm size.. |
| 108 | Providing and fixing liquid soap container with C.P. brass lid and brackets to wooden cleats with the same materials etc complete. (a) Glass container with CP lid and bracket |
| 109 | Providing and fixing toilet paper holder.(a) C.P. brass toilet paper holder of standard size. |
| 110 | Providing and fixing on wall face SWRPVC soil,waste and vent pipe including jointing with rubber lubricant/ cement solvennt complete.a) 110mm dia. |
| 111 | Providing and fixing SWRPVC plain bend of required degree ( 87.50° ) including jointing with rubber lubricant/cement solvent complete.a) 110mm dia |
| 112 | Providing and fixing SWRPVC plain bend of required degree (45°) including jointing with rubber lubricant/cement solvent complete.a) 110mm dia |
| 113 | Providing and fixing single equal SWRPVC plain junction of required degree with access door (T-junction) .a) 110x110x110mm. |
| 114 | Providing and fixing SWRPVC plain junction of required degree with access door (Y-junction) including jointing with rubber lubricant/cement solvent.a) 110mm Y-junction ofSWRPVCwith access door. |
| 115 | Providing and fixing SWRPVC socket including jointing with rubber lubricant/cement solvent.a) 100mm dia socket |
| 116 | Providing and fixing ventilation cowl including jointing with rubber lubricant/cement solvent complete.(a) 110mm SWRPVC vent cowl |
| 117 | Providing and fixing W.C. connection bend type (siphon) (SWRPVC) including jointing with rubber lubricant/ solvent cement.Siphon |
| 118 | Providing and fixing uPVC multi floor trap with floor trap grating including jointing with rubber lubricant/ solvent cement complete.Siphon |
| 119 | Providing and fixing vitreous Division Plate 69 x 30 cm size for Urinals. ii) Pastel |
| 120 | Water Supply InstallationProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall. b) 20mm dia nominal bore |
| 121 | Extra for concealed in brick and RCC works by making chases upto 7.5x7.5cm in walls and making good the same after housing pipes, etc. |
| 122 | Making connection of Astral CPVC pipes distribution branch by providing and fixing equal Tee with jointing, testing complete including cutting andmaking good etc. b) 20mm dia nominal bore |
| 123 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Elbow 90o with jointing, testing complete including cutting and making good etc. b) 20mm dia |
| 124 | Providing and fixing CPVC Ball valve/ Globe/Stop & Waste valve/ Boiler drain etc. Complete. b) 20mm nominal bore |
| 125 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (d) 20 mm nominal bore. |
| 126 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Male Adaptor (Brass) with jointing, testing complete including cutting and making good etc. b) 20mm nominal bore |
| 127 | Making connection of Astral CPVC pipes distribution branch by providing and fixing Female Adaptor (Brass) with jointing, testing complete including cutting and making good etc. b) 20mm nominal bore |
| 128 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (a) Sintex or quivalent |
| 129 | Providing and placing in position electric water pump of approved manufacture including connections to G.I pipes etc. complete with accessories.b) 750 watts |
| 130 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 131 | Providing and fixing 15mm nominal bore chromium plated brass bib cock of approved quality. C) Class-I |
| 132 | INTERNAL ELECTRIFICATIONSMAIN TO SUB-MAIN IN COPPER WIRE GRADE-III (THREE PHASES FOUR WIRES)Wiring in parallel system with PVC wire sheathedstandard copper conductor/wires as perIS:694(1977) and Life line Flame Retardant (FR) 1100 voltage graded stranded copper running inside PVC conduit pipe(medium Duty) 20/25/32/40/50mm dia\" fixed,recess inside the wall/ceiling /floor as per convenience including junction box having required numbers of ways from Main toSub-Main/DB,sub-main/DB to SDB/Switch boards/SDB to switch boards as required:-4X 10 Sqmm copper conductor/cable + 2 X 10 Sqmm earthwire |
| 133 | FOR LIGHT POINT,CEILING FAN POINT,EXHAUST FAN POINT ETC (MODULAR TYPE) Wiring in looping system with PVC wire sheathedstandard copper conductor/wires as perIS:694(1990) and Halogen Free Flame Retardant (HFFR) 1100 voltage graded copper flexiblewire stranded copper running inside PVC casing & capping (Gr-I) 20mm dia fixed, surface on thewall/ceiling/floor as per convenience including junction box having required numbers of ways fromcontrol switch to the light point etc as required:Very short point |
| 134 | Short point |
| 135 | Medium point |
| 136 | Long point |
| 137 | Very long ponit |
| 138 | Extra ordinary long point |
| 139 | FOR POWER PLUG/SOCKET POINT 15/16 AMPERES (MODULAR TYPE) Wiring in looping system with PVC wire sheathedstandard copper conductor/wires as perIS:694(1990) and Life shield- Halogen Free Flame Retardant(HFFR) 1100 voltage graded copperflexible wire stranded copper running inside PVC casing & capping (Gr-I) 30x12mm fixed, surface onthe wall/ceiling/floor as per convenience including junction box having required numbers of ways fromDB to the power plug/socket 15/16A point etc. as required:Medium point |
| 140 | Long point |
| 141 | Very long ponit |
| 142 | MAIN TO SUB-MAIN IN COPPER WIRE GRADE-I SURFACE (SINGLE PHASE TWO WIRES)Wiring in looping system with PVC wire sheathedstandard copper conductor/wires as perIS:694(1990) and Life shield- Halogen Free Flame Retardant(HFFR)/FR 1100 voltage graded copper flexible wire stranded copper running inside PVC Casing & capping(Grade-I) of all available sizesdiameter fixed,surface onthe wall/ceiling/flooras per convenience including junction box having required numbers of ways from Main to Sub-Main/DB/Sub-Main/DB to SDB/SDB/Switch boards/SDBto switch boards as required:-(A) 2X2.5sqmm |
| 143 | 2X 4 Sqmm copper conductor/cable + 1x 4.0 Sqmm earthwire |
| 144 | SUPPLYING AND FIXING OF SWITCH BOARDS ( MODULAR TYPE ) grade-I Supplying and fixing of Modular switch board of the following sizes/modules on surface/recess including PVC/Steel boxes,modular plate and necessary switches,plug/socket, and fan regulators etc. with necessary painting if necessaryTwo modules 1 S2M |
| 145 | 2 S |
| 146 | Threemodule 3S( Cost for 1 SB ) |
| 147 | Fourmodule 4S( Cost for 1 SB ) |
| 148 | 1S (2M) + 1 SOC ( Cost for 1 SB ) |
| 149 | 2S + 1 R (2M) |
| 150 | Sixmodules 6S |
| 151 | 4 S (3S+1S with indicator) + 1 R (Cost for 1 SB) |
| 152 | Twelve modules8 S+ 2 R(2M)(Cost for 1 SB) |
| 153 | Eighteenmodules 16 S+ 2 BKP (Cost for 1 SB) |
| 154 | MCBs SP/SP&N/DP/TP/TP&N/FP:Supplying, and fixing of 5 Amps\" to 32 Amps\" SP rating 240 volts, B-series, Maniature Circuit BreakerSingle Poles (SP)of the following sizes in the existing MCB DB complete with connections, testing& commissioning etc, as required.5 Amps\" to 32 Amps\" rating,SP, MCB B- series |
| 155 | MCBs SP/SP&N/DP/TP/TP&N/FP:Supplying, and fixing of 50/63 Amps\" FP rating 240 volts, B-series, Maniature Circuit BreakerFour Pole (FP)of the following sizes in the existing MCB DB complete with connectionstesting & commissioning etc, as required.50/63 Amps\" rating,FP, MCB B- series |
| 156 | MCB DISTRIBUTION BOARDSupplying,fitting,&fixing of 8-Ways MCB DB single door in sheet steel,Phosphatised powder painted MCB DBs with Bus Bar, Neutral link,earth bar and din rail conforms to IS:13032,IS:8623,BS:5486 240 Volts 50 Hz, on surface/recess includinginter-connection,painting etc, as required8-ways MCB DB SP&N Single Door |
| 157 | EARTHING AND LOOP EARTHINGEarthing with CopperEarth Plate 600mmx600mmx6mm thick including accessories and provding masonery enclosure with cover plate having locking arrangment and water pipe, etc. ( but without charcoal or coke and salt ) complete as required. |
| 158 | Providing and fixing of 20mmx3mm copper strip on surface or in recess for connection etc. as required. |
| 159 | Providing and fixing of 8 SWG Copper Wire on surface or in recess for loop earthing alongwith the existing surface/recess conduit/sub-main wiring/cables etc.as required. |
| 160 | LIGHTNING ARRESTOREarthing with CopperEarth Plate 600mmx600mmx6mm thick including accessories and provding masonery enclosure with cover plate having locking arrangment and water pipe, etc. ( but without charcoal or coke and salt ) complete as required. |
| 161 | Providing and fixing of 20mmx3mm copper strip on surface or in recess for connection etc. as required. |
| 162 | Providing and fixing of 8 SWG Copper Wire on surface or in recess for loop earthing alongwith the existing surface/recess conduit/sub-main wiring/cables etc.as required. |
| 163 | Lighting arrestor one finger copper |
| 164 | FANS FIXTURESupplying,fitting and fixing of 1200mm 3 blade ceiling fanElectra 5 star (ISI) (Bajaj/Havells/Usha)certified company make completed with connection, etc. in completed. |
| 165 | Supplying,fitting and fixing ofExhaust fan150 sweep(ISI) (Bajaj/Havells/Usha)certified company make completed with connection, etc. in completed. |
| 166 | LIGHTING FIXTURESupplying,fitting and fixing of(Syska) SSK-T5T 18 watt LED tube surface type (ISI) certified company make completed with connection, etc. in completed. |
| 167 | Supplying,fitting and fixing of(Syska-Hi bay light) SSK-UFO Series -80 watt(ISI) certified company make completed with connection, etc. in completed. |
| 168 | Supplying,fitting and fixing of(Syska-Hi bay light) SSK-50watt Concealed Down light-T-24(ISI) certified company make completed with connection, etc. in completed. |
| 169 | Supplying,fitting and fixing of(Syska) SSK-STP-0501 5 watt Step foot light(ISI) certified company make completed with connection, etc. in completed. |
| 170 | Supplying,fitting and fixing of(Syska) SKK-TVP Panel light, -36 watt concealed type(ISI) certified company make completed with connection, etc. in completed. |
| 171 | Supplying,fitting and fixing of(Syska) SKK-ARIM-S-18 watt concealed type(ISI) certified company make completed with connection, etc. in completed. |
| 172 | Supplying,fitting and fixing of(Syska) SKK-B-22, 15 watt bulb(ISI) certified company make completed with connection, etc. in completed. |
| 173 | GRID MAIN PANEL (OUT DOOR TYPE)Out door type 3 Ph, Grid main panel complete set with400A aluminium bus bar,315A 50 KA FP MCCB as Grid main supply incomer and 315 A FP manual change over switch as Grid & DG supply incomer with 8nos of 100A 25KA FP MCCB distributor to each Sub Distributor with fitting of Volt meter and Ampere meter |
| 174 | OTHER SERVICESFire Hydrant System (Wet Riser)S/L of 80 mm dia. Pipe in R/F |
| 175 | SITC of Foot valve complete with all accessories. IS markedS/L of 80mm dia. |
| 176 | SITC of swing check type Non Return Valve complete with all accessories.S/L of 80mm dia. |
| 177 | SITC of Butter Fly Valve complete with all accessories. IS markedSITC of Single headed landing Hydrant Valve (G.M) IS marked |
| 178 | S/F of RRL Hose Pipe with M/F coupling (G.M) IS marked |
| 179 | S/F of short branch pipe (G.M) |
| 180 | SITC of Hose cabinet (750x600x250) 18 SWG thick M.S.fabric |
| 181 | 25 NB Air Release Valve |
| 182 | Motor with Oumo House and control panel with inbuild accessories |
| 183 | Overhead tanky (4000) ltr with all fitting accessories required. |
| 184 | SITC of 2 way fire brigade inlet connection 63 mm dia. Build-in non-return valve instanteneous coupling type. |
| 185 | Fire Exit board (radium) |
| 186 | Fire Alarm SystemFire Alarm System make RAVEL/AGNISITC of 8 Zone MASTER Digiti Addresable microprocessor based fire alarm panel with 12v/15Ah battery and in build battery charger. Make : AGNI |
| 187 | SITC of 8 Zone MASTER Digiti Addresable microprocessor based fire alarm panel with 12v/15Ah battery and in build battery charger. Make : AGNI |
| 188 | SITC of photo electric multi detector with base. Make: Appolo/S.Sensor |
| 189 | SITC of manual call point |
| 190 | SITC of hooter/sounder |
| 191 | Wiring Lying of fire alarm system with 2cr x 1.5 sq.mm copper cable, and PVC Pipe wall mounted with all necessories. (Approx Estimate.Actual After completion) |
| 192 | Fire ExtinguisherS/F of fire extinguisher type CO2 4.5 kg complete with all necessories. |
| 193 | S/F of fire extinguisher type ABC 4 kg complete with all necessories. |
| 194 | S/F of fire extinguisher type mechanical foam 50L complete with all necessories. |
| 195 | S/F of fire extinguisher Mudular type ABC 4 kg complete with all necessories. |
| 196 | Sinage of Fire EXIT AND ENTRY and others Fire sign as per this project(sqf). |
| 197 | S/F of firfe bucket round bottom type, enamel painted white inside. Handle with mounting bracket rate to included fire bucket and stand. |
| 198 | Sound SystemNEXO M10 (Main Line array Mid high) |
| 199 | NEXO M SUB 15 (Subwoofer) |
| 200 | NXAMP 4x4 (Amplifier 4 channel) |
| 201 | ARRAY FRAME (2 nos.*mid high and 2nos.*sub separate) |
| 202 | YAMAHA DHR12M (powered monitor speaker) |
| 203 | YAMAHA TF5 (48 channel digital mixing console) |
| 204 | SHURE SM 58 (dynamic microphone) |
| 205 | SHURE MX 418 (goosneck condenser mic) |
| 206 | SENNHEISER XSW 835 (wireless condenser microphone system) |
| 207 | SNAKE CABLE (32 channel with stage box and connectors)(100m) |
| 208 | MICROPHONE CABLE (signal cable)(200m) |
| 209 | Seaker cable (copper dual core 2.5mm)(200m) |
| 210 | ACESSORIES (connectors, stands and mounting hardwares) |
| 211 | CONTINGENCIES |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail