| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis ofmeasurement of finished quantity of work) (a) With earth obtained from excavation of foundation. |
| 3 | Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 4 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 5 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety |
| 6 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety |
| 7 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). |
| 8 | a) 25 mm to 30 mm shuttering without staging in foundation |
| 9 | b) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 10 | 250 mm thick Brick work with Fly Ash Bricks(250mmx125mmx75mm) as per IS 12894:2002 in cement mortar (1:6) |
| 11 | (a) In foundation and plinth (1:4) |
| 12 | (b) In superstructure, ground floor(1:6) |
| 13 | 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer\"s specification |
| 14 | 125 mm. thick Flyash brick work as per IS 12894:2002 in cement mortar (1:4) in ground floor. |
| 15 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. ( SRMB/ELEGANT STEEL CAPTAIN, BALAJI SHAKTI, HEXA, RUNGTA STEEL, ADHUNIK, SUPER SHAKTI, SALUJA GOLD, RASHMI TMT, SEL, SEL TIGER) |
| 16 | Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc. |
| 17 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white ...............cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.(i) 25 mm. Thick |
| 18 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). |
| 19 | (a) 15 mm thick plaster |
| 20 | (ii) With 1:4 cement mortar (b) 10 mm thick plaster |
| 21 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m. |
| 22 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 23 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc.fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and upto 16 Kg./sq. mtr. |
| 24 | Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038- ---------complete in all respect excluding glazing.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]manufactured from rolled steel sections conforming to IS 7452-1974with non-friction projecting type, box type hinges, glazing clips,lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respectexcluding glazing. |
| 25 | Applying Exterior grade Acrylic primer of approved quality and brandon plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterioremulsion paint including scraping and preparing the surface throughly,complete as per manufacturer\"s specification and as per direction of theEIC. |
| 26 | Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer\"s specification and as per direction ofEngineer-in-Charge to be applied over acrylic primer as required. Therate includes cost of material, labour, scaffolding and all incidentalcharges but excluding the cost of primer.In Ground floor (Two Coat)a) Normal Acrylic Emulsion |
| 27 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 28 | Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand------- on the surface, if necessary :On steel or other metal surface : |
| 29 | Supplying, fitting & fixing UPVC pipesand fittings conforming to IS:13592-1992 with all ---------------(Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. |
| 30 | A) UPVC Pipes: (i) 110 mm. Dia. (B-type) |
| 31 | Add @ 2.0 % for Electrical works |
| 32 | Add GST @ 18.0 % |
| 33 | Add CESS @ 1.00 % |
| 34 | Add below @ 3.0 % for Contingency |