Tender For Construction Of Govt. Tribal Boys Hostel Building (Capacity 1000) In Dr. Babasaheb Ambedkar University Premises, Chha. Sabhajinagar, Tal. And Dist. Chha. Sambhajinagar (Building No. 2 Capacity 500), Aurangabad-Maharashtra

Public Works Department-PWD has published Tender For Construction Of Govt. Tribal Boys Hostel Building (Capacity 1000) In Dr. Babasaheb Ambedkar University Premises, Chha. Sabhajinagar, Tal. And Dist. Chha. Sambhajinagar (Building No. 2 Capacity 500). Submission Date for this Tender is 24-01-2024. Building Work Tenders in Aurangabad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

41575530
Corrigendum : Tender For Construction Of Govt. Tribal Boys Hostel Building (Capacity 1000) In Dr. Babasaheb Ambedkar University Premises, Chha. Sabhajinagar, Tal. And Dist. Chha. Sambhajinagar (Building No. 2 Capacity 500)
Open Tender
Indian
Maharashtra
Aurangabad
24-01-2024

Tender Details

Construction Of Govt. Tribal Boys Hostel Building ( Capacity 1000 ) In Dr. Babasaheb Ambedkar University Premises, Chha. Sabhajinagar, Tal. And Dist. Chha. Sambhajinagar ( Building No. 2 Capacity 500 )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Jan-2024 Corrigendum No. 1 Date 24-01-2024
2 11-Jan-2024 Pre Bid Meeting Link Other 24-01-2024
3 15-Jan-2024 Revised Pre Bid Meeting Link Other 24-01-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 1213000.0 /-
Tender Value
INR 24.24 Crore /-

BOQ Items

Name of Work:Construction of Govt. Tribal Boy"s Hostel Building No. 2 (Capacity 1000) in Dr. Babasaheb Ambedkar University Premises, Aurangabad, Tal. & Dist. Aurangabad
Sl. No. Item Description
1Clearing grass and removal of rubbish up to required distance outside the periphery of the premises.
2Excavation for foundation in earth, soil of all types, sand, gravel and soft murum including removing the excavated material up to required distance beyond the building area, stacking and spreading as directed,dewatering if required, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete as directed including all leads and lifts.
3Excavation for foundation in hard murum including removing the excavated material up to required distance beyond the building area, stacking and spreading as directed,dewatering if required, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete as directed including leads and lifts.
4Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. as directed including all leads and lifts.
5Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material up to required distance beyond the building area, stacking and spreading as directed,dewatering if required, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete as directed including all leads and lifts.
6Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etcetera including removing the excavated material up to required distance beyond the building area, stackingand breaking of boulder to suitable sizeand spreading as directed,dewatering if required, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete as directed including all leads and lifts.
7Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
8Providing and laying Cast in situ / Ready Mix cement concrete Mix M-10 of trap metal for foundation and bedding including bailing out water if required, formwork, laying/pumping,compacting, finishing uneven and honey combed surface if required, curing etceteraetera. complete with fully automatic micro processor basedProgrammable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) with fine aggregate as finely washed Natural Sand / Vertical shaft Impactor Grade Crushed sand etcetera complete as directed including all leads and lifts.
9Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters TISCON, SAIL ,TATA Steel, RINL (Rashtriya Ispat Nigam Limited - Vizag), JSW orwith embossing of Indian Standard Institution Trade Mark and Thermo Mechanically Treated T Brand at every 1.00 meter interval on every bar confirming to Indian Standard 1786 for Reinforced Cement Concrete footings, columns, beams, lintels, chajjas, canopies, slabs, staircase, waist slas, pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending, hooking the bars, binding with Galvanised Ironbinding wires of appropriate gauge and supporting etcetera complete as required including allleads and lifts. (A) Ground Floor
10(B) First Floor
11(C) Second Floor
12(D) Third Floor
13(E) Fourth Floor
14(F) Fifth Floor
15Providing and laying in situ / Ready Mix M 30 grade cement concreteof trap metal for Reinforced Cement Concrete workin foundations like raft, strip foundations, grillage andfootings of Reinforced Cement Concrete columns and steel stanchions etcetera including bailing out water if required, formwork, laying / pumping, compaction and curing, finishing or roughening the surface if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Poly Vinyl Choride /precast concrete cover blocks of M-35 grade with galvanised binding wire of appropriate gauge at 1.50 metres centre to centre near the edge of each side and at centre when the width ismore than 75 centimeter reinfocement to give a clear cover of 40 milimeter to 65 milimeter from all sides as per Indian Standard 456-2000 with natural sand /Vertical Shaft Impactor quality artificial sandetcetera complete as directed. (excluding reinforcement and structural steel), ( including all leads and lifts )
16Providing and laying Cast in situ / Ready Mix M 30 grade cement concrete of trapmetal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Poly Vinyl Choride / precast concrete cover blocks of M-35 grade with galvanised binding wire of appropriate gauge at 1.50 metres centre to centre near the edge of each side and at centre when the width ismore than 75 centimeter to reinfocement to give a clear cover of 40 milimeter to 65 milimeter from all sides as per Indian Standard 456-2000 with natural sand /Vertical Shaft Impactor quality artificial Sand etcetera complete as directed. (excluding reinforcement and structural steel), ( including all leads and lifts) (A) Ground Floor
17(B) First Floor
18Providing and laying Cast in situ / Ready Mix M 25 grade cement concrete of trapmetal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Poly Vinyl Choride / precast concrete cover blocks of M-35 grade with galvanised binding wire of appropriate gauge at 1.50 metres centre to centre near the edge of each side and at centre when the width ismore than 75 centimeter to reinfocement to give a clear cover of 40 milimeter to 65 milimeter from all sides as per Indian Standard 456-2000 with natural sand /Vertical Shaft Impactor quality artificial Sand etcetera complete as directed. (excluding reinforcement and structural steel), ( including all leads and lifts) (C) Second Floor
19(D) Third Floor
20(E) Fourth Floor
21(F) Fifth Floor
22Providing and laying concrete pipes of Indian standard NP 2 class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench etcetera complete as directed including all leads and lifts
23Providing and casting in situ cement concrete M-30 of trap metal for Reinforced Cement Concrete beams and lintels per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Ploy Vinyl Chloride/ precast concrete cover blocks of M-35 grade with galvanised binding wire of appropriate gaugeS at 90 centimeter centre to centre to each main bottom bar and to stirrups at sides to give required clear cover from all sides as per Indian Standard 456-2000 with natural sand /Vertical Shaft Impactor quality artificial Sand etcetera. complete as directed.(excluding reinforcement and structural steel),( including all leads and lifts ) (A) Ground Floor
24(B) First Floor
25Providing and casting in situ cement concrete M-25 of trap metal for Reinforced Cement Concrete beams and lintels per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Poly Vinyl Chloride / precast concrete cover blocks of M-35 grade with galvanised binding wire of appropriate gaugeof required size with steel chairs at suitable spacingat 90 centimetre centre to centre to each main bottom bar and to stirrups at sides to give required clear cover from all sides as per Indian Standard 456-2000 with natural sand and suppling corrosion inhibiting admixture in concrete in every part POLYALK CP 293 of approve make, non-nitrite based corosion inhibiting admixture to be added at a dose of 3 kilogram per cubicmetre of concrete etcetera/Vertically Shaft Impactor quality artificial Sand etcetera complete as directed.(excluding reinforcement and structural steel)(including all leads and lifts) (C) Second Floor
26(D) Third Floor
27(E) Fourth Floor
28(F) Fifth Floor
29Providing and laying Cast in situ / Ready Mix M 30 grade cement concrete of trap metal for Reinforced Cement Concrete chajja as per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Ploy Vinyl Chloride / precast concrete cover blocks of M-35 grade with galvanised binding wire of appropriate gaugeof required size with steel chairs at suitable spacingat the rate of 27 Numbers per 10 Square metre to reinforcement to give required clear coveras per Indian Standard 456-2000 with natural sand /Vertical Shaft Impactor quality artificial sand etcetera. complete as directed.(excluding reinforcement and structural steel),( including all leads and lifts ) (A) Ground Floor
30(B) First Floor
31Providing and laying Cast in situ / Ready Mix M 25 grade cement concrete of trap metal for Reinforced Cement Concrete chajja as per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Ploy Vinyl Chloride / precast concrete cover blocks of M-35 grade with galvanised binding wire of appropriate gaugeof required size with steel chairs at suitable spacingat the rate of 27 Numbers per 10 Square metre to reinforcement to give required clear coveras per Indian Standard 456-2000 with natural sand /Vertical Shaft Impactor quality artificial sand etcetera. complete as directed.(excluding reinforcement and structural steel),( including all leads and lifts ) (C) Second Floor
32(D) Third Floor
33(E) Fourth Floor
34(F) Fifth Floor
35Providing and fixingduring laying in Reinforced Cement concrete Slabrectangular 2 millimetre thickMild Steel sheet fan hook box ofsize 180 X 100 millimetre with required depthwith holes or notches as required, bottom and top sides of 1.6 millimetre Mild Steel sheet fixed with 3.5 millimetre diametre round headed screws together with 12 millimetre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface etcetera complete as directed. (A) Ground Floor
36(B) First Floor
37(C) Second Floor
38(D) Third Floor
39(E) Fourth Floor
40(F) Fifth Floor
41Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap metal for Reinforced Cement Concrete slabs and landingsas per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Ploy Vinyl Chloride / precast concrete cover blocks of M-35 grade of required size with galvanised binding wire of appropriate gauge at the rate of 27 Numbers per 10 Square metre to reinforcement to give required clear coveras per Indian Standard 456-2000 with steel chair at suitable size natural sand /Vertical Shaft Impactor quality artificial Sand etcetera. complete as directed.(excluding reinforcement and structural steel),( including all leads and lifts ) (A) Ground Floor
42(B) First Floor
43Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for Reinforced Cement Concrete slabs and landingsas per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Ploy Vinyl Chloride / precast concrete cover blocks of M-35 grade of required size with galvanised binding wire of appropriate gauge at the rate of 27 Numbers per 10 Square metre to reinforcement to give required clear coveras per Indian Standard 456-2000 with steel chair at suitable size natural sand /Vertical Shaft Impactor quality artificial Sand etcetera. complete as directed.(excluding reinforcement and structural steel),( including all leads and lifts ) (A) Ground Floor
44(C) Second Floor
45(D) Third Floor
46(E) Fourth Floor
47(F) Fifth Floor
48Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite / quartzite / gneiss metal for Reinforced Cement Concrete canopy as per detailed designs and drawings including centering, formwork, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing etcetera complete (excluding reinforcement), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (including all leads and lifts)
49ProvidingandlayingCastinsitu or ReadyMixcementconcreteinM-30oftrap orgranite or quartzite orgneissmetalforReinforced Cement Concretepardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying orpumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedProgramilimeterable Logic ControllerwithSupervisory Control And Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as requiredcomplete.Withfineaggregate(Crushed sand Vertical Shaft Impact Grade),( including all leads and lifts ) (A) Ground Floor
50(B) First Floor
51ProvidingandlayingCastinsitu or ReadyMixcementconcreteinM-25oftrap orgranite or quartzite orgneissmetalforReinforced Cement Concretepardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying orpumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedProgramilimeterable Logic ControllerwithSupervisory Control And Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as requiredcomplete.Withfineaggregate(Crushed sand Vertical Shaft Impact Grade),( including all leads and lifts ) (A) Ground Floor
52(C) Second Floor
53(D) Third Floor
54(E) Fourth Floor
55(F) Fifth Floor
56Providing and laying Cast in situ / Ready Mix cement concrete inM-30 of trap metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Ploy Vinyl Chloride / precast concrete cover blocks of M-35 grade of required size with galvanised binding wire of appropriate gauge at the rate of 27 Numbers per 10 Square metre to reinforcement to give required clear coveras per Indian Standard 456-2000 with steel chair at suitable size natural sand /Vertical Shaft Impactor quality artificial Sand etcetera. complete as directed.(excluding reinforcement and structural steel),( including all leads and lifts ) (A) Ground Floor
57(B) First Floor
58Providing and laying Cast in situ / Ready Mix cement concrete inM-25 of trap metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed designs and drawing or as directed including centering, formwork, laying/pumping, compaction and curing, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided with fully automatic micro processor based Programilimeterable Logic Logic Controller with Supervisory Control and Data Concrete shall be mixed in ready mix plant deployed at site transported and pumped to the desired location as required and placing Ploy Vinyl Chloride / precast concrete cover blocks of M-35 grade of required size with galvanised binding wire of appropriate gauge at the rate of 27 Numbers per 10 Square metre to reinforcement to give required clear coveras per Indian Standard 456-2000 with steel chair at suitable size natural sand /Vertical Shaft Impactor quality artificial Sand etcetera. complete as directed.(excluding reinforcement and structural steel),( including all leads and lifts ) (C) Second Floor
59(D) Third Floor
60(E) Fourth Floor
61(F) Fifth Floor
62Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricksin Cement Mortor 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etcetera complete as directed including all leads and lifts.
63Filling in plinth and floors with approved excavated materialincluding watering and compacting after laying them in layers of 15 centimetre to 20 centimetreetcetera complete as directed.(including all leads and lifts)
64Filling in plinth and floors with contractors material brought from outside and approved by Engineer in charge including watering and compacting after laying them in layers of 15 centimetre to 20 centimetreetcetera complete as directed.(including all leads and lifts)
65Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO )
66Providing dry trap rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etcetera complete as directed.(including all leads and lifts)
67LABOUR RATE ONLY : Providing dry trap rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etcetera complete as directed.(including all leads and lifts)
68Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer (Siporex / Ultratech / Magicrete /ecolite / everest / Aerocon ) confirming to Indian Standard 2185 Part III 1984 of size 625 x 240 x 225 millimetre in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent for walls in superstucture including, striking joints, racking out joints watering and scaffolding etceteracomplete as directed including all leads and lifts. (A) Ground Floor
69(B) First Floor
70(C) Second Floor
71(D) Third Floor
72(E) Fourth Floor
73(F) Fifth Floor
74Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer (Siporex / Ultratech / Magicrete /ecolite / everest / Aerocon ) confirming to Indian Standard 2185 Part III 1984 of size 625 x 240 x 100 millimetre in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick partition walls including 2 hoop iron strips 25 millimetre x 1.6 millimetre at every third course, properly bend and bonded at ends scaffolding racking out joints and watering etcetera compete as directed including all leads and lifts. (A) Ground Floor
75(B) First Floor
76(C) Second Floor
77(D) Third Floor
78(E) Fourth Floor
79(F) Fifth Floor
80Providing andlaying Castinsitu/ReadyMixcement concrete M-20oftrap/ granite/quartzite/gneissmetalforcoping to plinthorparapet,mouldedorchamferedasper drawingorasdirectedincludingsteelcentering,plywood/steelformworkcompacting, rougheningthemifspecialfinishistobeprovided,finishingunevenandhoneycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.) With fine aggregate (Crushed sand Vertical Shaft Impactor Grade), ( including all leads and lifts ) (F) Fifth Floor
81Providing and fixing Country Cut Teak Wood (CCTW) frame with / without ventilator of size as specified withfor main door on ground floorincluding chamfering, rounding, rebating, iron holdfast of size 300 millimetre x 40 millimetre x 5 millimetre with oil painting, etcetera complete including all leads and lifts
82Providing and fixing M-40 grade precast concrete door frame of size 60 millimetre x 100 millimetre vibrated pull cast or similar typewith chamfer conforming to Indian Standard 6524-1983 having 6 millimetre diametres bars 3 Numbers and stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars500 millimetrelongincluding cleaning the frame surface, necessary primer and oilpainting of appoved make and colour shade etcetera complete as directed including all leads and lifts. (A) Ground Floor
83(B) First Floor
84(C) Second Floor
85(D) Third Floor
86(E) Fourth Floor
87(F) Fifth Floor
88Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick of approved color and shade for boxing to toilet doors, window and ventilator frames etcetera at approved locations on Cement Mortor 1:6 including filling joints with polymer base filler, moulding / nosing the sharp edges wherever necessary, curing, cleaning etcetera complete as directed including all leads and lifts. (A) Ground Floor
89(B) First Floor
90(C) Second Floor
91(D) Third Floor
92(E) Fourth Floor
93(F) Fifth Floor
94Providing and fixing green marble of 18 to 20 millimeter thick for door frame/ dado/ window boxing etcetera on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing etcetera complete including all leads and lifts. (A) Ground Floor
95(B) First Floor
96(C) Second Floor
97(D) Third Floor
98(E) Fourth Floor
99(F) Fifth Floor
100Providing and fixing mild steel grill work for windows, ventilators etcetera 20 Kilogram Per One Square Metre asperdrawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete. (A) Ground Floor
101(B) First Floor
102(C) Second Floor
103(D) Third Floor
104(E) Fourth Floor
105(F) Fifth Floor
106Providing and constructing granite kitchen platform on ground floor at approved location with fixing of stainless steel sink 600 millimetre x 450 millimetre size of as per detailed drawing including polished kadappah stone 25 to 30 millimetre thick vertical supports on both sideand intermediate vertical support at suitable distance of polished kadappah stone 25 to 30 millimetre thick with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite including half round moulding to granite slab at sink etcetera complete as directed including all leads and lifts. (B) First Floor
107Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforced Cement Concrete members and brick/ Autoclaved Areaclaved Concrete block work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry/ Autoclaved Areaclaved Concrete block masonry and/ or tying by binding wire etcetera complete as directed including all leads and lifts (A) Ground Floor
108(B) First Floor
109(C) Second Floor
110(D) Third Floor
111(E) Fourth Floor
112(F) Fifth Floor
113Providing internal cement plaster 12 millimeter thick in single coat in cement mortar 1:4 without neeru finish to concrete or brickor Autoclved Areaclaved Concrete bloack surfaces in all positions including scaffolding and curing etcetera complete as directed.(including all leads and lifts) (A) Ground Floor
114(B) First Floor
115(C) Second Floor
116(D) Third Floor
117(E) Fourth Floor
118(F) Fifth Floor
119Providing and fixing black kadappa stone as shelves 25 milimetre thick machine polished, extending the polish upto 20 centimetre width on lowerside, rounding corners, laying in position jointing with bedding cement mortar 1:4 proportion curing etcetera complete. (A) Ground Floor
120(B) First Floor
121(C) Second Floor
122(D) Third Floor
123(E) Fourth Floor
124(F) Fifth Floor
125Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etcetera complete including all leads and lifts.
126Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etcetera complete.
127Providing antitermite treatment around the periphery of the existingbuilding as per Indian Standard6313(Part-Hi)by excavating trenches of 20 centimeter width and exposing the sides of columns and plinth beams upto a depth of 300 millimetre and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per Running metre and refilling the trenches etcetera complete covering 2 years guarantee on bond paper.
128Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetera complete as directed.(including all leads and lifts) (A) Ground Floor
129(B) First Floor
130(C) Second Floor
131(D) Third Floor
132(E) Fourth Floor
133(F) Fifth Floor
134Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etcetera as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etcetera and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etcetera complete (A) Ground Floor
135(B) First Floor
136(C) Second Floor
137(D) Third Floor
138(E) Fourth Floor
139(F) Fifth Floor
140Providing patti/ band 150 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick at terrace levelin Cement Mortor1:3 in line and level including neat finishing, scaffolding, curing etcetera complete as directed. (F) Fifth Floor
141Providing Waterproofing Treatment to new terrace by using Chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge. , followed by average 112 millimeter thick brick bat coba covered with 40 millimeter thick Indian Patent Stone. The procedure includes fillng of cracks on the Reinforced Cement Cncrete slab with high performance polyurethane (liquid appiled) membrane. Clean the entire surfec thoroughly and over this prepared surface , apply a primer coat of high performance polyurethane (liquid applied) membrane as approved by Engineer incharge. Apply he primer by roller. Extend the coating to parapet walls including the top of parapet . Alow the primer coat to set for 24 hours. After the primer coat is set , apply two coats of clorinated paraffinated talcum polyurethane (CPTP) Elastomeric membrane as approved by Engineer incharge on surface.(including all leads and lifts)Ensure that pinholes are touched up properly. while the second coat og high performance polyurethane (liquid applied) membrane is wet and taky , sprinkle coarse sand over the surface to make it rough and provide mechanical key for further treatment. Provide and lay average 50mm thick protective coat of Cement Mortar in 1:4 over the surface and allow to set and cure. Provide and lay 112 millimetre thick Brick bat coba in average thickness in cement mortar 1:5 with one pouch of 330 grams of thorough blend of special cement , adlehyde based polymer , shrinkage compensating agents as approved by Engineer incharge per 50 kilogram bag of cement and finshing with 40 millimetre thick Indian Patent Stone layer in M20 Cement Concrete by miing one pouch of 330 grams of above admixtures per 50 kilogram bag og cement , including all leads , lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta , bevel of champhered portion at the junction of parapet and work upto height of 300millimetre or as directed and including finishing the top layer of water proofing treatment. with false marking of 30 centimetre X 30 centimetre or as directed , curing and covering the whole treatment. The liqud membrane should have a track record of at least 4 years in india and have atleast an 4 year track record in PWD .Single component, liquid applied, chlorinated paraffinated talcum polyurethene( CPTP) elastomeric membrane should have following minimum properies :1) Water Permeability (DIN 1048 ): Nil as per DIN 1048 @ 7 bar of Hydrostatic pressure. 2) Moisture permeability : <0.4 grams per Square metre per day 3) Accelerated weathering (Indian Standard 101) : 2000 hours no cracking / blister formation 4) Adhesion to concrete (ASTM D 1000 ) :>21 kilogram per cubicmetre 2 (concrete fails) 5) tensile strength :> 2.0 Mega Pascal (ASTM D412 ) 6) should not be watered soluble are water dilutable 7) Shore a hardness : 40+_ 5 (ASTM D2240 ) 8) Elongation at break : > 900 percent (ASTM D 412 ) 9) Solids : > 95 percent10) No micro -bubble formation or blistering should take place during the curing of thick films. (A) Ground Floor
142(F) Fifth Floor
143Providing and fixing Poly Vinyl Chloride Rain water pipes of 110millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard. 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25millimetre to 40millimetre from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement.Concrete. or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Vinyl Chloride. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetera complete. (The contractor shall give 3 years guarantee bond for payment) (A) Ground Floor
144(B) First Floor
145(C) Second Floor
146(D) Third Floor
147(E) Fourth Floor
148(F) Fifth Floor
149Providing and fixing on walls / ceiling / floor 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain /Astral make for water supply including fixing Galvanised Iron bracket of required size to keep the pipe 40 to 65 millimetre away from face of walls and fixing with U clip nut bolt with necessary fittings, remaking good the demolished portion etcetera complete as directed. (A) Ground Floor
150(B) First Floor
151(C) Second Floor
152(D) Third Floor
153(E) Fourth Floor
154(F) Fifth Floor
155Providing and fixing on walls/ceiling/floor 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain /Astral make for water supply including fixing Galvanised Iron bracket of required size to keep the pipe 40 to 65 millimetre away from face of walls and fixing with U clip nut bolt with necessary fittings, remaking good the demolished portion etcetera complete as directed. (A) Ground Floor
156(B) First Floor
157(C) Second Floor
158(D) Third Floor
159(E) Fourth Floor
160(F) Fifth Floor
161Providing and fixing on walls/ceiling/floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain /Astral make for water supply including fixing Galvanised Iron bracket of required size to keep the pipe 40 to 65 millimetre away from face of walls and fixing with U clip nut bolt with necessary fittings, remaking good the demolished portion etcetera complete as directed. (A) Ground Floor
162(B) First Floor
163(C) Second Floor
164(D) Third Floor
165(E) Fourth Floor
166(F) Fifth Floor
167Providing and fixing screw down for 25 millimetre diametre wheeled stop tap of brass including necessary sockets/union nut complete. (A) Ground Floor
168(B) First Floor
169(C) Second Floor
170(D) Third Floor
171(E) Fourth Floor
172(F) Fifth Floor
173Providing and fixing on walls/ ceiling/ floor 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain /Astral make for water supply including fixing Galvanised Iron bracket of required size to keep the pipe 40 to 65 millimetre away from face of walls and fixing with U clip nut bolt with necessary fittings, remaking good the demolished portion etcetera complete as directed. (A) Ground Floor
174(B) First Floor
175(C) Second Floor
176(D) Third Floor
177(E) Fourth Floor
178(F) Fifth Floor
179Providing and fixing on walls/ ceiling/ floor 40 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain /Astral make including fixing Galvanised Iron bracket of required size to keep the pipe 40 to 65 millimetre away from face of walls and fixing with U clip nut bolt with necessary fittings, remaking good the demolished portion etcetera complete as directed. (A) Ground Floor
180(B) First Floor
181(C) Second Floor
182(D) Third Floor
183(E) Fourth Floor
184(F) Fifth Floor
185WaterproofingTreatmenttonewToilet/bathroombyusingPolymericCementitiousMembrane as approved by Engineer in charge, followed by 112 millmetre thick brick bat coba covered with 20 millimetre mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents.Iftherearelotsofhoneycombsandidentifiedbadpatchesofconcretethesameshouldbe grouted as per the instructions of site incharge. (The grouting shall bepaid separately). Clean the entire surfacethoroughlyandoverthispreparedsurface,apply threecoatsofpolymericCementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) basedpolymericwaterproofingsolutionasapprovedby Engineerin charge.Provideandlay 112millimetre averagethicknesofbrickbatcobaincementmortar1:5over12millimetre thickCement Mortar1:3bedding withone pouchof330gramsofthoroughblendofspecialcements,aldehydebasedpolymers,shrinkage compensating agentsas approved by Engineer in charge per 50 Kilogram bag of cement and finishing with 20 millimetre thick cement plaster in cement mortar 1:3 by mixingone 330 grams pouch of above admixture per 50 Kilogram bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bellmouthincludingwatta,beveledorchampheredportionatthejunctionofwallandworkuptoa height of 300 millimetre or as directed and including finishing the top layer of waterproofing treatement with falsemarkingof30centimeterx30centimeterorasdirected,curingandcoveringthewholetreatment.MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties:1) Elongation percent (ASTM D412-2016): @ 100 percent 2) Tensile Strength Newton per Square millimetre (ASTM D412- 2016): 3.3 3) Specific Gravity: 1.02 ± 0.024) Total Solids (ASTM D1644-2012): 43.98 5) Hardness Shore A (ASTM D2240-2015): 82 (including all leads and lifts) (A) Ground Floor
186(B) First Floor
187(C) Second Floor
188(D) Third Floor
189(E) Fourth Floor
190(F) Fifth Floor
191Providing waterproof plaster in Water Closet and bath 12 millimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kilogram per bag of cement of approved make and manufacturer and curing etcetera complete.(Excluding Tiles) (As directed by Engineer in Charge) (A) Ground Floor
192(B) First Floor
193(C) Second Floor
194(D) Third Floor
195(E) Fourth Floor
196(F) Fifth Floor
197Providing and fixing Orrisa type white glazed of Indian Standard earthenware 590 x 410 millimetre water closet pan of Hindware / Cera / Jaquar/Parryware/ Jonhson make including "P" trap, monolithic white earthenware foot rests, Unplasticized Poly Vinyl Chloride soil and vent pipes upto the outside face of the wall including 100 millimetre diameter Unplasticized Poly Vinyl Chloride plug bend, Cement Concrete 1:5:10 bedding 15 millimetre thick, 10 litres capacity Poly Vinyl Chloride flushing cisternwith fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 millimetre diametre Unplasticized Poly Vinyl Chloride flush pipe with all necessary fittings and clamps and making good the walls and floors etcetera complete as directed. (A) Ground Floor
198(B) First Floor
199(C) Second Floor
200(D) Third Floor
201(E) Fourth Floor
202(F) Fifth Floor
203Providing and fixing European type white glazed earthenware water closet pan of Hindware / Cera / Jaquar/Parryware/ Jonhson make with Unplactised Poly Vinyl Chloride seat and lid with chromium plated brass hinges and rubber buffers including Unplactised Poly Vinyl Chloride soil and vent pipe up to the outside face of wall,10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 millimetre diametre Unplactised Poly Vinyl Chloride flush pipe with fittings and clamps , 20 millimetre diametre Unplactised Poly Vinyl Chloride overflow pipe, mosquito proof couplings with water Jet and fitting including cutting and making good to the walls and floors testing etcetera complete as directed. (A) Ground Floor
204(B) First Floor
205(C) Second Floor
206(D) Third Floor
207(E) Fourth Floor
208(F) Fifth Floor
209Providing and fixing 10 centimetre Poly Venyl Chloride Nahani Trap with grating etcetera complete. (A) Ground Floor
210(B) First Floor
211(C) Second Floor
212(D) Third Floor
213(E) Fourth Floor
214(F) Fifth Floor
215Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with Poly Vinyl Chloride 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 millimetre diameter Poly Vinyl Chloride flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. (A) Ground Floor
216(B) First Floor
217(C) Second Floor
218(D) Third Floor
219(E) Fourth Floor
220(F) Fifth Floor
221Providing and fixing White glazedearthenware Wash Hand Basin of 55 x 40 centimetre size of Hindware / Cera / Jaquar/Parryware/ Jonhson make with bottle trap including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including Unplactised Poly Vinyl Chloride waste pipe and trap upto the outside face of the wall, making good the damaged surface,testingetcetera complete as directed. (A) Ground Floor
222(B) First Floor
223(C) Second Floor
224(D) Third Floor
225(E) Fourth Floor
226(F) Fifth Floor
227Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition both side polished of approved colour and shade with rounding the edges etcetera complete as directed. (A) Ground Floor
228(B) First Floor
229(C) Second Floor
230(D) Third Floor
231(E) Fourth Floor
232(F) Fifth Floor
233Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 millimetre thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg in charge etcetera complete. (A) Ground Floor
234(B) First Floor
235(C) Second Floor
236(D) Third Floor
237(E) Fourth Floor
238(F) Fifth Floor
239Providing, laying and fixing Poly Vinyl Chloride pipe of 110 millimetre diameter of Finolex/ Supreme/ Jain /Astral make for soil / vent pipes including fixing Galvanised Iron bracket of required size to keep the pipe 40 to 65 millimetre away from face of walls and fixing with U clamps nut boltwith fittings such as bends, tees, reducers etcetera including necessary excavation, trench filling etcetera complete as directed. (A) Ground Floor
240(B) First Floor
241(C) Second Floor
242(D) Third Floor
243(E) Fourth Floor
244(F) Fifth Floor
245Providing, laying and fixing Poly Vinyl Chloride pipe of 75 millimetre diametre of Finolex/ Supreme/ Jain /Astral make for soil / vent pipes including fixing Galvanised Iron bracket of required size to keep the pipe 40 to 65 millimetre away from face of walls and fixing with U clamps nut bolt with fittings such as bends, tees, reducersincluding necessary excavation, trench filling etcetera complete as directed. (A) Ground Floor
246(B) First Floor
247(C) Second Floor
248(D) Third Floor
249(E) Fourth Floor
250(F) Fifth Floor
251Providing and fixing in position Unplasticized Poly Vinol Chloride ultra violet stabilized 110 millimetre outer diameter cowl dome confirming to IS.-4985 including making joints with solvent cement etcetera complete (F) Fifth Floor
252Providing and laying for 150 millimetre diametre salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions, laying,jointing including excavation and refilling the trenches, etcetera complete as directed.
253Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap etcetera complete as directed.
254Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre average depth including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, brick masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete Cover etcetera complete as directed.(including all leads and lifts)
255Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre average depth including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Galvanised Stone Ware pipes, brick masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete Cover etcetera complete as directed.(including all leads and lifts)
256Providing and fixing Poly Vinyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre of Finolex/ Supreme/ Jain /Astral makeconfirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, including fixing Galvanised Iron bracket of required size to keep the pipe 40 to 65 millimetre away from face of walls and fixing with U clamps nut bolt of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetera complete. (The contractor shall give 3 years guarantee bond for payment)
257Providing soak pit of size 120 centimetre x 120 centimetre x 120 centimetre including excavating and filling with brick-bats.
258Providing and fixing 45 centimetre wide mild steel ladder of 40 millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diametre mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre x 30 centimetre x 30 centimetre and painting the ladder etcetera complete as directed. (Anti Corossive Paint)
259Providing and fixing heavy duty reinforced cement concrete cover of 225 kilogram of size 90 centimetre x 45 centimetre with frame over inspection chamber etcetera complete as directed.
260Providing and applying two coats of wall care putty of approved make on plastered surface and ceiling and wallsto prepare surface even and smooth to receive painting , etcetera complete as directed. (A) Ground Floor
261(B) First Floor
262(C) Second Floor
263(D) Third Floor
264(E) Fourth Floor
265(F) Fifth Floor
266Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 millimeter dia. 1.2 millimeter thick with multiple points head 1.2 metre long ( Heavy Duty) weldedor clamped to Galvanised Iron pipe pole B grade 50 millimeter diametre of requiired length with Mild Steel round bnase plate 25 centimetre diametre and 10 millimeter thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 millimeter diametre 2 meter length burried in earth upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
267Providing and fixing copper strip 25 millimeter wide and 3 millimeter thick for lightening conductor including fixing with screws required scaffolding etceteracomplete Note- Lightening conductor and earthing pits is not considered in this item
268Providing and laying in trenches 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain / Astral make for water supplyincluding necessary excavation, fittings. refilling trenches etcetera complete as directed.
269Providing and laying in trenches 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain / Astral make for water supply including necessary excavation, fittings. Refilling trenches etcetera complete as directed.
270Providing and laying in trenches 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain / Astral make for water supply including necessary excavation, fittings. Refilling trenches etcetera complete as directed.
271Providing and laying in trenches 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain / Astral make for water supply including necessary excavation, fittings. Refilling trenches etcetera complete as directed.
272Providing and laying in trenches 40 millimetre diametre Chlorinated Poly Venyl Chloride pipe of Finolex/ Supreme/ Jain / Astral make for water supply including necessary excavation, fittings. Refilling trenches etcetera complete as directed.
273Providing and fixing 25 millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber].
274Providing and making Indian Standard Institute Mark ferrule connection of 32 millimetre diametre to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
275Providing and laying Antiskid Ceramic tiles of approved quality of company Johnson /RAK / Kajaria / Nitco / Asian or equivalent make of size 30 centimetre x 30 centimetre and confirming to Indian Standard 15622-2006 (Group-B HA) for antiskid flooring in toilet area laid on a bed of cement mortar 1:4including cement float, filling joint with cement slurry cleaning curing etcetera complete as directed. (Including all leads and lifts) (A) Ground Floor
276(B) First Floor
277(C) Second Floor
278(D) Third Floor
279(E) Fourth Floor
280(F) Fifth Floor
281Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre confirming to corresponding India Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etcetera complete. (including all leads and lift) (A) Ground Floor
282(B) First Floor
283(C) Second Floor
284(D) Third Floor
285(E) Fourth Floor
286(F) Fifth Floor
287Providing and fixing Mild Steel grill door 24 kilogram per square metre of various size on ground floor as per detailed drawings without hot dip coating, iron fixtures and fastenings and oil painting in three coats of approved make and shade etcetera complete as directed.
288Providing and laying handcut polished Kotah Stone flooring 25 millimetre to 30 millimetre thick and 30 centimetre x 45 centimetre sizein plain pattern at approved location on a bed ofCement Mortar 1:6 including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etcetera complete as directed. (A) Ground Floor
289(B) First Floor
290(C) Second Floor
291(D) Third Floor
292(E) Fourth Floor
293(F) Fifth Floor
294Providing sills of required material 20 millimeter to 25 millimeter thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete a) marble other than white makrana (B) First Floor
295(C) Second Floor
296(D) Third Floor
297(E) Fourth Floor
298(F) Fifth Floor
299Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 millimeand meter rooms including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning etcetera complete as directed. (Including all leads and lifts) (A) Ground Floor
300(B) First Floor
301(C) Second Floor
302(D) Third Floor
303(E) Fourth Floor
304(F) Fifth Floor
305Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size, 18 millimetre to 20 millimetre thick for flooring on ground floor at approved location on bed cement mortar 1:6 including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etcetera complete as directed. (Including all leads and lifts)
306Providing and laying chequered tiles of approved quality of company RAK / Kajaria / Nitco / Asian or equivalent make of size 30 centimetre x 30 centimetre for plinth protection at approved location in required position laid on a bed of cement mortar 1:4including cement float, filling joint with cement slurry cleaning curing etcetera complete as directed.
307Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stonefor treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of Cement mortar 1:4including float filling joints with neat cement slurry,curing,polishing and cleaning etcetera complete as directed. (A) Ground Floor
308(B) First Floor
309(C) Second Floor
310(D) Third Floor
311(E) Fourth Floor
312(F) Fifth Floor
313Providing and fixing welded mesh of 11 gauge wires having mesh size 50 millimetre x 25 millimetre including Mild Steel Angle frame of size 35 millimetre x 35 millimetre x 5 millimetre in position with oil painting 3 coats etcetera complete
314Providing and fixing mat finish stainless steel lettering (School Building Name) 30 to 45 centimetere height as directed by Engineer-in-Charge including labour, material, cleaning, scaffolding, all leads and lifts etcetera complete. (A) Ground Floor
315(B) First Floor
316(C) Second Floor
317(D) Third Floor
318(E) Fourth Floor
319(F) Fifth Floor
320Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etcetera complete. (A) Ground Floor
321(B) First Floor
322(C) Second Floor
323(D) Third Floor
324(E) Fourth Floor
325(F) Fifth Floor
326Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces, (excluding the primer coat.) etcetera complete. (A) Ground Floor
327(B) First Floor
328(C) Second Floor
329(D) Third Floor
330(E) Fourth Floor
331(F) Fifth Floor
332Providing and applying two coats ofexterior acraylic emulsion paint confirming to corresponding Indian Standard of Asian / Nerolac / Berger/ Dulux/ Shalimarmake and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etcetera complete as directed. (A) Ground Floor
333(B) First Floor
334(C) Second Floor
335(D) Third Floor
336(E) Fourth Floor
337(F) Fifth Floor
338Providing and fixing Country Cut Teak Wood (CCTW) Four leafpaneled shutters, 35 millimetre thick style and rail and 25 millimetre thick panels without ventilator for main door on ground floor as per detailed drawing excluding the door frame, stainless steelfixtures and fastening and finishing the wood work with oil painting 3 coats complete as directed.
339Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, approved chromium plated fixtures and fastenings with brass mortise lock, approved chromium plated handles on both sides and finishing with french polish etcetera complete as directed. (A) Ground Floor
340(B) First Floor
341(C) Second Floor
342(D) Third Floor
343(E) Fourth Floor
344(F) Fifth Floor
345Providing and applying melamine polish of required finish to the woodwork on ground floor by spray machine includingknottingand preparing the even surface by scraping, applying French polish , scaffolding if required etcetera complete.
346Providing and applying two coats of synthetic enamel paint of Asian / Nerolac / Berger/ Duluxmake of approved colour to new structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etcetera complete as directed. (A) Ground Floor
347(B) First Floor
348(C) Second Floor
349(D) Third Floor
350(E) Fourth Floor
351(F) Fifth Floor
352Providing and fixing fiber glass reinforced polyster door shutter 30 millimetre thick as per Indian Standard 14856 (2000) (Reaffirmed 2006) without ventilator including approved chromium plated fixtures and fastening with chromium plated handles on both sides, etcetera complete as directed. (A) Ground Floor
353(B) First Floor
354(C) Second Floor
355(D) Third Floor
356(E) Fourth Floor
357(F) Fifth Floor
358Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 millimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 millimetre at weight 1.070 kilogram per running metre, Top and side track section 92 x 31.75 x 1.30 millimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 millimetre at weight 0.417 kilogram per running metre. Inter locking section 40 x 18 x 1.10 millimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 millimetre at weight 0.417 kilogram per Running metre, as per detailed drawings and as directed by Engineer in charge with all necessary aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain transperent acrylic sheet and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts,with powder coating of approved shade and thickness without box etcetera complete as directed. (A) Ground Floor
359(B) First Floor
360(C) Second Floor
361(D) Third Floor
362(E) Fourth Floor
363(F) Fifth Floor
364Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etcetera complete. (A) Ground Floor
365(B) First Floor
366(C) Second Floor
367(D) Third Floor
368(E) Fourth Floor
369(F) Fifth Floor
370Providing and Fixing mat finish stainless steel (of 302 grade) railing with toppipe of 50 millimetre diametre and vertical pipe of 38 millimetre diameter at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre diametre in three rows, all pipes of 2 millimetre thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre diametre above newel post of 75 millimetre diameter etcetera complete. (Prior approval of sample and brand by Executive Engineer is necessary before use) (A) Ground Floor
371(B) First Floor
372(C) Second Floor
373(D) Third Floor
374(E) Fourth Floor
375(F) Fifth Floor
376Providing and fixing 15 millimetre diameter Quarter Turn bib/ stop tap of brass including necessary socket union nut complete. (A) Ground Floor
377(B) First Floor
378(C) Second Floor
379(D) Third Floor
380(E) Fourth Floor
381(F) Fifth Floor
382Providing and fixing 15 millimetre diameter concussion push button type brass/gun metal self-closing tap including necessary socket complete. (A) Ground Floor
383(B) First Floor
384(C) Second Floor
385(D) Third Floor
386(E) Fourth Floor
387(F) Fifth Floor
388Providing and fixing screw down 15 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete (A) Ground Floor
389(B) First Floor
390(C) Second Floor
391(D) Third Floor
392(E) Fourth Floor
393(F) Fifth Floor
394Providing and fixing Chromium Plated sink cock with raised J" shaped swinging casted spout of approved make including necessary sockets/ union nut etcetera complete." (B) First Floor
395Providing and fixing Chromium Plated wall mixer with provision for overhead shower with 115 millimetre long bend pipe and wall flange of approved make including necessary sockets/union nut etcetera complete (A) Ground Floor
396(B) First Floor
397Providing and fixing chromium plated towel rod 16 millimetre diametre and 75 centimetre in length including all accessories complete. (A) Ground Floor
398(B) First Floor
399(C) Second Floor
400(D) Third Floor
401(E) Fourth Floor
402(F) Fifth Floor
403Providing and fixing 450 millimetre x 550 millimetre size superior type Belgium mirror with 16 milimetre diametre nickel plated towel rod etcetera complete. (A) Ground Floor
404(B) First Floor
405(C) Second Floor
406(D) Third Floor
407(E) Fourth Floor
408(F) Fifth Floor
409Making 150 millimetre diametre Bore in all types of Strata with head core including survey for fixing location of bore transporting of machinery and platform, providing laying fixing casing of 150 millimetre diametre Unplacticised Poly Vinyl Chloride Pipe (CS as per Indian Standard : 12815) having outer diametre 165 and minimum thickness of 5.70 to 6.50 millimetre diametre along with grouting, checking capacity by flushing test etcetera complete. Making Bore in all types of strata
410Providing and Laying and fixing casing of 150 millimetre diametre Ultra Poly Vinyl Chloride pipe to withstand continous internal hydraulic pressure of 6 kilogram per square centimetre (Cross Section as per Indian Standard : 12818-1992) having outer diametre 165.40 millimetre and minimum thickness 5.70 to 6.50 millimetre along with grouting.
411Checking Capacity by Flushing test
412Supplying and erecting submersible pumpset of 2.25 Killo Watt /3 Horse Power with 415 Volt, 50 c/s Altenating Current supply suitable for 150 milllimetre diametre borewell 3 Horse Power (2 stage) suitable for 200 to 500 Litre Per Minute discharge at 21 to 11 metre head and (maximum efficiency at 19 metre head and 300 lit.re per minute) discharge and delivery Pipe of Size-50 millimetere diameter with a necessary H type clamps as per specification number WPSMP.
413Supplying and erecting flat flexible 3 core 2.5 square millimetre Poly Vinyl Chloride sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
414Supplying and erecting D.O.L. Starter 400 Volt 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 Horse Power.
415Providing and fixing 90 centimetre x 60 centimetre Granite plate engraving 10centimetre height letter, figures including painting the lefters / figures with approved colour and shade etcetera complete as directed.
416Providing and fixing board displaying information, such as "Name of work, Tender cost, Name of Contractor, Work completion and liability period etc", having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 metre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etcetera with approved colour shade paint complete, on Mild Steel angle of size 35 x 35 x 3 millimetre frame with properly cross braced Mild Steel angles of size 35 millimetre x 35 millimetre x 3 millimetre duly painted including Two Mild Steel angle iron posts of size 65 millimetre x 65 millimetre x 6 millimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures etceteraand fixing the boards in 1:4:8 concrete block of size 60 centimetre x 60 centimetre x 75 centimetre including, excavation, refilling, transportation, and labour etcetera complete. Specification Number As directed by Engineer in Charge
417Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 milimetre thickwith 3 milimetrediameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etcetera complete. (A) Ground Floor
418(B) First Floor
419(C) Second Floor
420(D) Third Floor
421(E) Fourth Floor
422(F) Fifth Floor
423Providing and fixing in position colour anodised aluminium fixed window fully glazed in 2 half parts (top and bottom) for ventilators at approved locations as per detailed drawing and as directed by Engineer in charge with all necessary alluminium sections including necessary fixtures and fastening such as 5 millimetre thick clear float glass and stainless steel jali between top and bottom partwith powder coating of approved shade and thickness etcetera complete as directed. (A) Ground Floor
424(B) First Floor
425(C) Second Floor
426(D) Third Floor
427(E) Fourth Floor
428(F) Fifth Floor
429Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres (F) Fifth Floor
430Providing expansion joints in reinforced cement concrete framed structure (interior columns) with plain premoulded fillerwith confirming to Indian Standard 1838,1961, 25 millimetre thick with 75 millimetre wide and 1 millimetre thick stainless steel plate finishing etcetera complete as directed. (A) Ground Floor
431(B) First Floor
432(C) Second Floor
433(D) Third Floor
434(E) Fourth Floor
435(F) Fifth Floor
436Providing expansion joints in Reinforced Cement Concrete framed structure (exterior column) with plain premoulded filler 25 millimeter thick with 75 millimeter wide and 1 millimeter thick stainless steel plate and finishing etcetera complete. (A) Ground Floor
437(B) First Floor
438(C) Second Floor
439(D) Third Floor
440(E) Fourth Floor
441(F) Fifth Floor
442Providing expansion joints in Reinforced Cement Concret framed structure (at floor level) with plain premoulded filler 25 millimeter thick with 75 millimeter wide and 1 millimeter thick stainless steel plat and finishing etcetera complete. (A) Ground Floor
443(B) First Floor
444(C) Second Floor
445(D) Third Floor
446(E) Fourth Floor
447Providing expansion joints in Reinforced Cement Concrete framed structure (at Terrace level) with premoulded filler 25 millimeter thick with 40 millimeter wide and 1 millimeter thick stainless steel plate as required, bitumen poured filler and finishing etcetera complete as directed. (F) Fifth Floor
448Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded Ultra Voilet protected multicell panels incorporated into a complete system. Co-extrudedUltra Voilet protected polycarbonatepanelsystemofmin12millimetrethickof900millimetre(minute.)widthwithangular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility and strength. Panels with all fixing accessories to ensure best performance for wind uplift,vibration,oilcanningandvisualappearance.Panelsshallbemanufacturedwith vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectorswithdoubletoothgriplocklockingmechanismandwillbesecuredonMild Steel structure(willbepaidSeparately)with3numbersself-drillingscrewsandtrapezoidStainless Steel fasteners holding the base of the standing seam offering best stability having a pull-out load of min.7000 Newton(7Kilo Newton)testedasperIndain Standard Organisation6892:1998andIndian Standard1608:2005,asperdesign requirement. Panels must satisfy Dart drop impact test as per Indian Standard 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to Ultra Voilet for a min. of 500 Hours as per ASTMG 155. Panels shall not have Yellowness Indexas per ASTM D 1925 of 15 units when tested on a sample exposed to Ultra Voilet for 500 Hours as per ASTM G 155. U value shallnotbemorethan1.6Watt per square metre KasperENIndian Standard Organisation10077-2:2018. (F) Fifth Floor
449Providing and laying damp proof course 50 millimetre thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etcetera complete.
450Part -2 Electrical 1.2 PVC Flexible/Rigid Conduits/Casing-n-Capping/Under Floor Trunking/Raceways and Box System (WG-MA/CON) Supplying and erecting 20mm dia. corrugated flexiblepolypropyleneconduit
451Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON.
452Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize40 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON.
453Supplying anderectingPVCboxtrunking ofsize50x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX.
454Supplying anderectingPVCboxtrunking ofsize 75x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX.
4551.3 Bunch of Wires (WG-MA/BW) Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
456Supplying and erecting GREEN EARTH with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
457Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
458Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire for earthing laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
459Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
460Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire for earthing laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
4611.6 Modular switches and Accessories Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
462Supplying and erectingmodular type switch 16 / 20 Awith indicator,duly erected on provided plate and box with wiring connections complete.
463Supplying and erectingmodular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete.
464Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete.
465Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.
466Supplying and erectingmodular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
467Supplying and erectingmodular type telephone socket one gangwith safety shutter, duly erected on provided plate and box with wiring connections complete.
468Supplying and erectingmodular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
469Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
470Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.
471Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
472Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
473Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
474Point Wiring(PW) 1.7 Point Wiring (WG-PW) Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW
475Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW
476Secondary point wiring for additionallight/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
4772.1 Indoor LED Fittings (FG-IDF/LED) Supplying and erectingLED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
478Supplying and erectingLEDPanel Light(600mm X 600mm) Max. 35 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
479Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
480Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 1) Driver and luminaire shall be of same make. 2) LM79 and all other reports of all luminaires shall be from accredited NABL laboratory. 3) Manufacturer Logo shall be embossed on all pressure die cast Luminaires and logo shall not be screen-print / sticker type. 4) All luminaires shall conform to respective IS.
4812.3 Accessories for Indoor Fittings (FG-AS) Supplying and erecting double suspension heavy duty lacquered iron chain with hooks for erecting fluo. tube light fitting(for erecting various fixtures like FTL, LED, etc)with necessaryshielded copper flexible wire threecoreof1 sqmm for connecting leads. (for measurements halfofthe actual length used)
482Supplyinganderecting Electronic type cordlesscallbell erected on T.W.board havingportablebellpush working on 9V D.C. battery and(effective range upto 45 meter) bell on 250 V A.C. supply.
4832.10 Fans (FG-FN) Supplying and erectingenergy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
484Supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPMwith speedregulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation.
485Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
4862.11 Accessories for Fans (FG-FN) Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
487Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
488Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
4891.8 Telephone, Audio and Video Wiring (WG-TW/TW) Supplying & erecting2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as perspecification No. WG-TW
490Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephonecopper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed havinglaid in provided trench as per specification No. WG-TW
491Supplying & erecting 100 pair, 0.5 mm dia. jelly filled armoured telephonecopper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed havinglaid in provided trench as per specification No. WG-TW
492Supplying & erecting 0.5 mm dia, copper jumper wire as per specification No. WG-TW
493Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW
494Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW
495Supplying and erecting 3m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
496Supplying and erecting 15m Audio Video cord low voltage grade as per specificationwith required 3RCA x 3RCA connector complete.
497Supplying & erecting HDMI Extender Over RJ45 Ethernet Cable Cat 6, 60m/200ft complete.
4981.9 Telephone Accessories (WG-TW/TA) Supplying, erecting & commissioningMDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
499Supplying, erecting & commissioningMDF Box 150x150 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
500Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
501Supplying, erecting & commissioning10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW
502Supplying & erecting over voltage protection magazine suitable for 10 pair as per specification no. WG-TW
503Supplying and erecting broadband splitter unit with 1 input & 2 output RJ 11 female connectors complete.
504Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of6 x 32 extensions suitable upto 96 extensions complete.
5051) Add Rs. 38159.00 for additional 16 extension card for digital (hybrid) type EPABX
506Supplying, installing, testing & commissioningpush button telephone instrument desk top unit as per specification complete
507Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.
508Supplying, installing, testing & commissioning IP telephone instrument as per specification complete.
509Supplying & installing expansion cabinet for extension of digital hybrid EPABX to expand system by 32 ports with programming and configuration of extensions and Direct lines with required accessories complete.
5101.10 ELV Cabling (WG-COC) Supplying and installing enhanced cat-6 LSZH cable with 4-connector channel Performance test report as per ANSI/TIA-568.2-D suitable for networking complete as per specification.
511Supplying and installing cat-6 armouredcable with ECCS tape suitable for networking as per specification No. WG-COC/NC
512Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-Din position as per specification No. WG-COC/PC
513Supplying and plugging 3 m fibre patch cord LC-SC MM (50) OM3 LSZH duplex complete as per specification no. WG-COC/FPC
5141.11 Networking Components (WG- NWC) Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete.
515Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS
516Supplying, fixing, and configuring modularised multi-service router 802.11/a/n/ac unified Wave 2.5 GHz, with RJ-45 port, supporting1 to 13 channels for 2.4 GHz, with unified wireless access point complete.
5171.12 Networking Accessories (WG-NAS) Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
518Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
519Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ
520Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
521Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coatedmetal with necessary arrangement for fixingas per specification No. WG-NAS/RAK
522Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
523Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAK
524Supplying and fixing dual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrentaccess point with POE in networking as per specification no. WG-NAS/LAP2
525Supplying, installing and activating physical license pack software for multiple access point with management, configuration and trouble shooting for all access point in network complete.
5267.1 LT Cables (Aluminium) (CB-LT/AL) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core16sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
527Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core150sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
5287.11Cable Tray (CB-CT) Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
529Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. 1) Standard accessories shall typically include : a) "Z" section support - 30 x 35 mm in size - 312 mm in length - 6 nos. support for one piece ladder of 2.5 m in length each. b) Anchor fastener & nut bolts of adequate size - 16 nos. (2 nos. persupport) c) Coupler plates with hardware - 70 x 200 x 3 mm thick - 2 nos. for each piece of 2.5 m ladder complete with necessary accessories such as reducer, horizontal elbow & tee, up & down vertical elbow & bends, cross piece complete. 4) Both type of cable trays shall be earthed properly.
530Chapter: 3 APPLIANCES (AP) 3.3 Water Coolers & Refrigerators (AP-WC) Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification no. APWCR/ WC
5313.5 Water Purifiers (WPF) Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.
5325.3 LT - MCBs/ MCB(SW-MCB) Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
533Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB
5345.6RCCB / RCBO (SW-RCCB) Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivitywithearth leakage trip indicationcomplete as per specification no. SW-RCCB/RCCB
535Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
536Supplying&erectingtriplepole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flushmounted,IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
537Supplying&erectingtriplepoleand neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flushmounted,IP 43 Protection on iron/GI frame (horizontal busbar type)as per specification no. SW-SWR/MCBDB
538Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
539Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
540Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
541Supplyinganderectingblankingplate of suitable size on MCBDB. 1) All MCBs shall have rated short-circuit breaking capacity not less than 10kA. 2) Reduce rate by 5% if angle iron frame/ GI frame is not required. 3) For more than 2 kW load RCCB shall invariably be provided & erected preferably in the same distribution board. (RCCB+MCB) or (RCCB+MCCB etc.). Separate box for RCCB/ELCB is not permissible. 4) DBs and allied switchgears must be of same make. 5) DBs with IEC 61439 part 1 & 3 and minimum IK 08 rating shall be preferred. MCCB Panel Boards and Accessories (SW- SWR-MCCBPB) for floor wise Distribution
542Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TPMCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
543Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
544Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
5455.11Accessories for MCCB"s Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8)
5465.7 MCCB Panel Boards and Accessories (SW- SWR-MCCBPB) Main LV Panel Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 4 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
547Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
548Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
549Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 4 way outgoing or 400A incoming and 2 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
5505.11Accessories for MCCB"s Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8)
551Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8)
5526.5 Accessories Supplying&erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on providedbox / panelwith necessary material, wiring & connections etc.
553Supplyinganderecting Intelligentflushmountedpanel meter three phase four wire (IPM) input voltage measurement range50-550 V AC (P-P) 415V, aux. supply 90-300 V AC/DC,flush mounted (96 x 96 mm) meter constant Wh viewing in LCD multifunction meters in auto scroll modewith voltage, current,frequency, powerfactor kW, kVA, kVAR, kWh, kVAh, kVARh, phase angle, interrupts, THD, complete with RS 485 communication protocol, class 1 accuracy andwiringconnectionsandmountinghardwareonprovided panels complete with calibration certificate from manufacturer.
5546.1 Sheets Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. M. S. Sheet 2 mm, Size of L.T. Panel 3 Mtr X 2 Mtr X 1 Mtr = 28 Sq. Mtr. @15.7 Kg/Sq.mtr=484 Kg outdoor installation Double door with canopy
555Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. MS angle 50 * 50 * 6 mm = 22 meter @ 3.8 kg/meter
556Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
5576.7 APFC Panel) (CP-ED) Supplying and erecting 75 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating ,APFC panel shall be compliance to IEC 61439 and power qualityIEC 61921 standard as per specification no CP-ED/APFC
5588.1 Steel Poles (OH-PL) Supplying and erecting steel tubular swan neck swaged type welded pole with upper portion hydraulically bent , 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm thickness (5.6+2.7+2.7 m) respectively total (net vertical height 10 m.) 11 m long with base plate in provided foundation. (weight 175 kg) as per specification no. OH-PL/STP
5598.2 Hot Dipped Galvanized Poles & High-Mast (OH-HM) Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as perspecification no.OH-PL/HM (excluding luminaries)
560Highmast Control Panels Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, , IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coatedwith supporting angles, self lock, gasket and slanting top erected on CC foundation complete. Rates are inclusive of foundation.
561Street Light Control Panels Supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in builtastronomical adjustable programmable timer with minimum 5 years battery back up, having IP54,IK10 protection, 4 pole contactor up to 60A, with maintenance mode to switch ON street lights during time of repairs with energy consumption data recording for analysis and LCD display for energy monitoring with numeric key padin provided box.
5629.1 Plate, Pipe type Earthing (EA-EP) Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP
5632.4 Outdoor Fittings (FG-ODF/LED) Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2.
564Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2.
5657.8 Street Light Boxes & Cable Indicators(CB-SB/CB-CIP) Supplying & erectingcast iron cable indicatorplate buried along with route of cable for PVC / XLPE armoured cableas per specification No. CB-CIP
566Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.
56716.3 C.C. Foundation Makingcement concrete foundation including excavation(60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal,45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)
568Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).
56910.1 Non-sealed transformer Supplying, installing, testing & commissioning3 phase, 11/0.433 kV, 50 Hz., 160 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium woundNon-sealed transformer , delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40? by thermometer in oil and 45? by the resistance methodin winding at full load rating, using type A winding insulation (kraft paper), with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 670 Watts at 50% load, 1950 Watts at 100% load as per IS:1180 (part 1) : 2014with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.
570Supplying, installation, testing and commissioning extendable/non-extendable indoor type 11 kV, 630A,load break switch, compliant to IEC 62271 -100, 200 and 102, on provided MS channels/trench/foundations per specification no SW-HTS / LBS
57110.6 Accessories Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
572Supplying and erecting 50 x 50 x 6 mm angle iron as cornersupport 2m long fixed at the middle ofthefencing frame and the otherside inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
573Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
574Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.).
575Providing printed instruction chart for treating persons suffering from electric shock, printedinEnglish & Marathi and duly laminated complete.
576Providingpair ofdulytestedrubber hand glovesas per IS :47705suitable forworking up to 22 kV supply complete.
577Supplying standardfirst aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
578Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class A insulation conforming to IS: 15652 – 2006having 2 mm thickness up to 3.3 kV
579Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV
580Generators (GEN) 11.1 Generators (GEN-GEN) Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 27.8 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 290 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG 2) For all engines, the emission standards/norms shall meet applicable pollution control board norms as amended by government.
58111.2 Auto Mains Failure Panels (AMF Panels) (GEN-AMF) Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating setof above 140 kVA up to 180 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
5829.1 Plate, Pipe type Earthing (EA-EP) Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP
583Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with insulating and non-corrosive bond with requiredjointsAs per specification no. EA-EP. GI strip 50X6 mm = 2.14kg/meter. Hence for 340 meters - 340*2.45 = 833 kg
584Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbonbased environment friendly back fill Ground Enhancing compoundcomplete with all materials, testing & recording the resultsas per specification no ESE -LA
585Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clampsfixed on wall painted with insulating and non-corrosive bond with requiredjoints As per specification no. EA-EP. Cu strip 50X6 mm = 2.67kg/meter. Hence for 280 meters - 280*2.67 = 748 kg
5869.3 Lightning Conductor and Accessories Supplying & erectingconventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete.
587Providing and back filling ground enhancing compound 25 kg bag complete.
5887.3HT Cables (CB-HT) Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
5897.5 Cable Joints & End Termination Kits (HT Cables)(CB-JT/HT) Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
590Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
5917.6 Cable Enclosures (CB-CE) Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
592L. T. Metering Supplying anderectingLT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power completewithzeroadjustment&testcertificatefrom manufacturer erected on providedM.S. box and connected to CTs.
59316.2 Masonry Work Providing and making second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1:6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. (1.7 × .9 × 1.2 × 5 nos.)
594Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
595Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram).
59614 CCTV System (FF-CCTV) Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
597Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
598Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
599Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete.
600Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
601Supplying and erecting 3m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
602Supplying and installingcat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC
603Supplying and installing cat-6 armouredcable with ECCS tape suitable for networking as per specification No. WG-COC/NC
604Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
605Supplying& erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change etection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM.
606Supplying, installing, testing & commissioning of 32/40 Ch Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI1/VGA1 outputs, provided Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920x1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA ports, ANR Technology, 8 SATA interfaces for 8HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, support multibrand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications no. CCTV-NVR
607Supplying& erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S,maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB,MTBF 1000000 Hrs. HTTPS.RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD
608Supplying, installing and activating physical license pack software for multiple access point with management, configuration and trouble shooting for all access point in network complete.
609Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.
610Supplying& erecting 43" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON
611Supplying, erecting, testing and commissioning of single phase input & and 1 phase output 1 kVA capacity online pure sine wave UPS, with a backup time of 20 minutes. PWM & IGBT based,with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS
612Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire, duly charged with 12 months warranty complete
61313.3 Booster Pump (FF-MFP/BP) Supplying, installation, testing and commissioning ofbooster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operationwith IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevellingcomplete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
614Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
61513.6 Pipes (FF-PP) Supplying and erectingG.I. pipe‘C’ class ERW100 mm dia with necessary fittings complete asper specification no. FF-PP
616End Line Strainer (positive suction) (ELS) Supplying anderecting100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SSscreen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS
617Sluice Valve Supplyinganderecting100mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV
618Hydrant Valves (HV) Supplying anderectingstainless steel single outlethydrantvalve fitted with necessary accessories complete asper specification no. FF-VL/HV (Internal 16 Nos. + Courtyard 18 Nos.)
61913.8Fire Fighting Accessories (FF-FFA) Hose Reel with Drum (HR)Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose)along with necessary accessories complete asper specification no. FF-FFA/HV
620Hose Pipes Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m inlength, fitted with necessary accessories complete asper specification no. FF-FFA/RRL
621Nozzles (NZ) Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specifications no. FF-FFA/NZ
622Fire Brigade Connection (FBC) Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete asper specification no. FF-FA/FBC
623Air Release Valve (ARV) Supplying anderecting20/25mm dia gun metal air release cock, with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete asper specification no. FF-FFA/ARV
624MS / CRCA Boxes (BOX) Supplying and erecting M.S./CRCA cabinet for housing single hydrant valveof size ( 400 x 400 x 400)mm or hose pipe boxof size (600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mmhaving front doors with viewing glass of size (200x150) mmandlockingarrangement with necessary fixingmaterialsuch as rubber biddingetc. dulypainted in post box red colour( Code 538 of IS 5)
625Supplying and erecting M.S./CRCA cabinetfor housingFloorHydrant valve,hosepipe,hosereeland branch pipe(size 1000 x 736 x 736mm.)madefrom16SWG sheetandangle iron 25 x 25 x 4 mm. having front doors with viewingglass(8"x6") andlocking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
62613.13 Fire Sealant System (FF-FRM) Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
62713.15 Fire Extinguisher Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
628Epoxy painting on both side of approved colour shade of provided iron work / MS / CRCA sheet steel work complete along with anti-rust treatment complete.
629Supplying and erecting of FIRE EXIT & FIRE EXTINGUISHER signage indicating the floor number in words & system siganages. (FIRE EXTINGUISHERS & ACCESSORIES)
630Supplying, installing, testingand commissioning FRLS, XLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU
63113.9 Conventional Fire Alarm System (FF-FAS) Supplying, erecting, testing and commissioning manual call point (Pill box) with break glass push button andflip abort switch or agent release switch in metal enclosure complete asper specification no. FF-FAAS/MCP
632Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete asper specification no. FF-FAAS/HTR
633Supplying, installing, testingand commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2CharacterLCDDisplay, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC,0 - 49 Deg C,93 ± 2 Percentage RH (non- condensing) at 32± 2 Deg C complete asper specification no. FF-FAAS/FACP
63413.11 P A System (FF-PAS) Supplying, erecting,testing and commissioning 120 W amplifiersuitable to operate on 230VoltsA.C. / 12VoltsD.C. supply complete asper specification no. FF-PA/AFR
635Supplying,erecting, testing and commissioning 15 to 30 Watts soundcolumn or ceiling mounted complete asper specification no. FF-PA/SOC
636Supplying,erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metreshielded cable and 3 Pin Professional XLR Connector, stereo jack complete asper specification no.FF-PA/MIC
637Supplying,erecting, testing and commissioningrust free microphone table stand of chrome plating/powder coating or S.S. material,up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.
638Supplying,erecting, testing and commissioning of 2 core shielded cable complete asper specification no.FF-PA/MCC
639Supplying,erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.
64017-1New Installation SITC of Electric Traction Passenger Liftwith ·       Rated capacity :- 10 Passenger/680Kg ·       Floors :-G+5 floor (6 Stops / 6 Landings) ·       Travel :-20 mtrs ·       Location of Lift Machine:- MR ·       Rated speed :- 1.0mps VS ·       Car/Landing door clear opening of 800 mm wide x 2000 mm high ·       Clear Carsize of 1300 mm wide x 1350 mm deep x2250 mm high ·       Lift shaft available having clear size of 1800 mm wide x 3000 mm deep, 1600 mm Pit depth, 4200 mm Overhead. Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). ·       Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. ·       COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. ·       LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. ·       Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary Protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ·       ARD complete with necessary SMF VRLA batteries. ·       Fireman controller having fireman switch at fire Landing. ·       CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. ·       Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. ·       Other mechanical parts such as "T" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. ·       Minor civil work such as alteration work if any necessary for erection of landing door frames and it"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. "· General: - Job includes entire procedure of obtaining all necessary erection permissions & ""License to Work the Lift"" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning."
641For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.
642For Full Collective control system, add as below. For Lift travellingabove First floor & up to Sixth floor
643SITC of Duplex Lift control system fortwo nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.
644Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
645Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
646Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core4sq mm copper conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
647Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core2.5sq. mm. copper conductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
6489.1 Plate, Pipe type Earthing (EA-EP) Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP
649Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. GI strip 25X6 mm = 1.25kg/meter. Hence for 160 meters - 160*1.25 =kg
650Providing, erecting & commissioning 4 pole RCCB 40A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB
651Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
652Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
653Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
654Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO
655Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON.
656Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
657Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
658Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
659Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
660Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
661Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete.
662Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete.
663Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.
664Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
665Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected.
666Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW
667Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW
668Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
669Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF
670Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
671Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
672Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
673Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm.
674Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
67512.1 Centrifugal pumps Supplying & erecting Minimum three & above star rated Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of2.25 KW/3 HP with discharge 600/110 Litres per Minute (LPM) for head of 13/43 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP
67612.2 Submersible pumps for Borewell(Wp-SMP) Supplying and erecting minimum Three & above star rated submersible pump set of 3 KW/4 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 130 to 390 LPM discharge at 64 to 18 m head &discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP
67712.4 Accessories Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
678Supplying & erecting Water level controller 230/415 V, A.C. , Two way under ground tank operation only.
679Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
680Supplying & erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos)
681Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
682Supplying & erecting Float sensor switch for water level controllerworking on 250V & rated current 8A, with 2 mtr. wire & High quality of wire & plastic body.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail