Power Development Department has published Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 2X25 Kva & 1X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Joffer Mottu. Submission Date for this Tender is 31-01-2024. Conductor Tenders in Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Joffer Mottu Stage First. |
2 | 9 mtr. Long ST Pole (ST-410 SP-33) |
3 | GI V Cross -arm with top Bracket including clamps |
4 | GI Channel X-arm including clamps and Angle for braces |
5 | 30mm² ACSR Weasel Conductor |
6 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
7 | PG Clamps |
8 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
9 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
10 | Galvanized Nuts and Bolts |
11 | Danger Plates with Clamps |
12 | Anti climbing device with clamps |
13 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
14 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
15 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
16 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
17 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 2x25 KVA Sub stn. at WSS Joffer Mottu Stage First. |
18 | 11/0.433kV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate |
19 | Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type |
20 | 11 kv GO, AB Switch 3 phase 3 pole 200 Amp Vertical |
21 | 11 kV Horn GapFuse Set 3 Phase 200A |
22 | 95 mm² Single Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type |
23 | 9 mtr. Long ST Pole (ST-410 SP33) |
24 | 11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting |
25 | GI Channel/Angle/Flat of sizes including clamps |
26 | Galavinized Nuts and Bolts. |
27 | LT Fuse set made 50x6mm angle iron and 50x6mm Aluminium Bus bar strip fixed on Bus Bar insulator. |
28 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
29 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover. |
30 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSSJoffer Mottu Stage First. |
31 | 8 mtr. Long ST poles (ST-410 SP15) |
32 | GI M Clamps for shackle insulator |
33 | 30mm²ACSR Weasel Conductor |
34 | Shackle insulator |
35 | Galvanized Nuts and Bolts. |
36 | Danger Plates with Clamps |
37 | Anti climbing device with clamps |
38 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
39 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
40 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
41 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
42 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Joffer Mottu Stage second. |
43 | 9 mtr. Long ST Pole (ST-410 SP-33) |
44 | GI V Cross -arm with top Bracket including clamps |
45 | GI Channel X-arm including clamps and Angle for braces |
46 | 30mm² ACSR Weasel Conductor |
47 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
48 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
49 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
50 | Galvanized Nuts and Bolts |
51 | Danger Plates with Clamps |
52 | Anti climbing device with clamps |
53 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
54 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
55 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
56 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
57 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 63 KVA Sub stn. at WSS Joffer Mottu Stage Second. |
58 | 11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate |
59 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
60 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
61 | 11 KV Horn gap fuse set 3 phase 200 A |
62 | 120mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
63 | 9 mtr. Long ST poles (ST-410 SP33) |
64 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
65 | GI Channel /Angle/flat of sizes including clamps |
66 | Galvanized Nuts and Bolts. |
67 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
68 | 11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
69 | LT distribution box for 63 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits |
70 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
71 | PG Clamps |
72 | Danger Plates with Clamps |
73 | GI Barbed wire for Anticlimbing |
74 | 3-Phase 4 Wire LT Prodigy Meter with Box. |
75 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
76 | Painting of ST poles 9 mtr. Long with 2 coat of Aluminum paint. |
77 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSSJoffer Mottu Stage First. |
78 | 8 mtr. Long ST poles (ST-410 SP15) |
79 | GI M Clamps for shackle insulator |
80 | 30mm²ACSR Weasel Conductor |
81 | Shackle insulator |
82 | Galvanized Nuts and Bolts. |
83 | Danger Plates with Clamps |
84 | Anti climbing device with clamps |
85 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
86 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
87 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
88 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |