Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 2X25 Kva & 1X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Joffer Mottu, Udhampur-Jammu And Kashmir

Power Development Department has published Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 2X25 Kva & 1X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Joffer Mottu. Submission Date for this Tender is 31-01-2024. Conductor Tenders in Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41570441
Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 2X25 Kva & 1X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Joffer Mottu
Open Tender
Indian
Jammu And Kashmir
Udhampur
31-01-2024

Tender Details

Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 2X25 Kva & 1X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Joffer Mottu Under Jjm On Turnkey Basis.- 1 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Joffer Mottu Stage First. 2 9 Mtr. Long St Pole ( St-410 Sp-33 ) 3 Gi V Cross -Arm With Top Bracket Including Clamps 4 Gi Channel X-Arm Including Clamps And Angle For Braces 5 30Mm² Acsr Weasel Conductor 6 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 7 Pg Clamps 8 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 9 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 10 Galvanized Nuts And Bolts 11 Danger Plates With Clamps 12 Anti Climbing Device With Clamps 13 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 14 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 15 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 16 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 17 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 2X25 Kva Sub Stn. At Wss Joffer Mottu Stage First. 18 11 / 0.433Kv, 3-Phase 25 Kva Distribution Transformer With Bimetallic Terminal Connectors Energy Level-2, Aluminium Wound, And With Lv Cable Box Havingdetachable Aluminium Gland Plate 19 Gapless Surge Arrestor 9Kv, 10Ka, La With Polymer Housing Station Type 20 11 Kv Go, Ab Switch 3 Phase 3 Pole 200 Amp Vertical 21 11 Kv Horn Gapfuse Set 3 Phase 200A 22 95 Mm² Single Core Cable, 1.1Kv Grade, Pvc Insulated Alumnium Stranded Conductor Frls Type 23 9 Mtr. Long St Pole ( St-410 Sp33 ) 24 11Kv Polymeric Composite Disc Insulator 12Kv, Min Failing Load 45Kn, Lightening Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm With Tension Fitting 25 Gi Channel / Angle / Flat Of Sizes Including Clamps 26 Galavinized Nuts And Bolts. 27 Lt Fuse Set Made 50X6mm Angle Iron And 50X6mm Aluminium Bus Bar Strip Fixed On Bus Bar Insulator. 28 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum Per Pole 29 Earthing Of Substation --Excavation Of Earth Pit Of Dia 650 Mm & Depth 3000 Mm, Installation Of Earthing Pipe Of 40 Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr Long As Per Is 1239. Gi Strip For Neutral Earthing Of Size 50 Mm X 6 Mm & 32Mm X 3Mm For Connection Of Transformer Body, G.O Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts, Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover. 30 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wssjoffer Mottu Stage First. 31 8 Mtr. Long St Poles ( St-410 Sp15 ) 32 Gi M Clamps For Shackle Insulator 33 30Mm²acsr Weasel Conductor 34 Shackle Insulator 35 Galvanized Nuts And Bolts. 36 Danger Plates With Clamps 37 Anti Climbing Device With Clamps 38 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 39 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 40 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 41 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 42 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Joffer Mottu Stage Second. 43 9 Mtr. Long St Pole ( St-410 Sp-33 ) 44 Gi V Cross -Arm With Top Bracket Including Clamps 45 Gi Channel X-Arm Including Clamps And Angle For Braces 46 30Mm² Acsr Weasel Conductor 47 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 48 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 49 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 50 Galvanized Nuts And Bolts 51 Danger Plates With Clamps 52 Anti Climbing Device With Clamps 53 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 54 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 55 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 56 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 57 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 63 Kva Sub Stn. At Wss Joffer Mottu Stage Second. 58 11 / 0.433 Kv, 3-Phase Distribution Transformer 63 Kva With Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 59 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 60 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 61 11 Kv Horn Gap Fuse Set 3 Phase 200 A 62 120Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 63 9 Mtr. Long St Poles ( St-410 Sp33 ) 64 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 65 Gi Channel / Angle / Flat Of Sizes Including Clamps 66 Galvanized Nuts And Bolts. 67 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 68 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 69 Lt Distribution Box For 63 Kva Dtr With Mccb For Incomer And SfuS For Outgoing Circuits 70 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 71 Pg Clamps 72 Danger Plates With Clamps 73 Gi Barbed Wire For Anticlimbing 74 3-Phase 4 Wire Lt Prodigy Meter With Box. 75 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 76 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Aluminum Paint. 77 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wssjoffer Mottu Stage First. 78 8 Mtr. Long St Poles ( St-410 Sp15 ) 79 Gi M Clamps For Shackle Insulator 80 30Mm²acsr Weasel Conductor 81 Shackle Insulator 82 Galvanized Nuts And Bolts. 83 Danger Plates With Clamps 84 Anti Climbing Device With Clamps 85 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 86 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 87 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 88 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete

Key Value

Document Fees
INR 1000 /-
EMD
INR 62300.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Survey,Supply, Transportation, Carriage, Erection,Testing and Commissioning for Creation of 2x25 KVA & 1x63 KVA Sub station alongwith erection of 11 KV Line on 9 mtr. longST poles, 30mm SqACSRweasel conductor & LT line on 8 mtr. ST poleat WSS Joffer Mottu under JJM on turnkey basis.
Sl. No. Item Description
1Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Joffer Mottu Stage First.
29 mtr. Long ST Pole (ST-410 SP-33)
3GI V Cross -arm with top Bracket including clamps
4GI Channel X-arm including clamps and Angle for braces
530mm² ACSR Weasel Conductor
611 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
7PG Clamps
811 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
911 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting
10Galvanized Nuts and Bolts
11Danger Plates with Clamps
12Anti climbing device with clamps
13Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
14Painting of 9 mtr ST poles with two coats of Aluminiumpaint.
15Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
16Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
17Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 2x25 KVA Sub stn. at WSS Joffer Mottu Stage First.
1811/0.433kV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
19Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
2011 kv GO, AB Switch 3 phase 3 pole 200 Amp Vertical
2111 kV Horn GapFuse Set 3 Phase 200A
2295 mm² Single Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
239 mtr. Long ST Pole (ST-410 SP33)
2411kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
25GI Channel/Angle/Flat of sizes including clamps
26Galavinized Nuts and Bolts.
27LT Fuse set made 50x6mm angle iron and 50x6mm Aluminium Bus bar strip fixed on Bus Bar insulator.
28Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
29Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover.
30Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSSJoffer Mottu Stage First.
318 mtr. Long ST poles (ST-410 SP15)
32GI M Clamps for shackle insulator
3330mm²ACSR Weasel Conductor
34Shackle insulator
35Galvanized Nuts and Bolts.
36Danger Plates with Clamps
37Anti climbing device with clamps
38Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip
39Painting of 8 mtr ST poles with two coat of Aluminium Paint
40Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
41Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
42Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Joffer Mottu Stage second.
439 mtr. Long ST Pole (ST-410 SP-33)
44GI V Cross -arm with top Bracket including clamps
45GI Channel X-arm including clamps and Angle for braces
4630mm² ACSR Weasel Conductor
4711 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
4811 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
4911 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting
50Galvanized Nuts and Bolts
51Danger Plates with Clamps
52Anti climbing device with clamps
53Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
54Painting of 9 mtr ST poles with two coats of Aluminiumpaint.
55Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
56Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
57Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 63 KVA Sub stn. at WSS Joffer Mottu Stage Second.
5811/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate
59Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
6011 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
6111 KV Horn gap fuse set 3 phase 200 A
62120mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
639 mtr. Long ST poles (ST-410 SP33)
6411 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting
65GI Channel /Angle/flat of sizes including clamps
66Galvanized Nuts and Bolts.
67Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
6811 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
69LT distribution box for 63 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits
70Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
71PG Clamps
72Danger Plates with Clamps
73GI Barbed wire for Anticlimbing
743-Phase 4 Wire LT Prodigy Meter with Box.
75Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
76Painting of ST poles 9 mtr. Long with 2 coat of Aluminum paint.
77Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSSJoffer Mottu Stage First.
788 mtr. Long ST poles (ST-410 SP15)
79GI M Clamps for shackle insulator
8030mm²ACSR Weasel Conductor
81Shackle insulator
82Galvanized Nuts and Bolts.
83Danger Plates with Clamps
84Anti climbing device with clamps
85Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip
86Painting of 8 mtr ST poles with two coat of Aluminium Paint
87Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
88Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail