Bharat Sanchar Nigam Limited-BSNL has published Tender For Day To Day Repairs And Maintenance Works Of Emergent Nature In Cgmt Office Buildings And Compound At Bsnl Campus, Cto, Shillong For The Year 2023-2024.(Half Yearly). Submission Date for this Tender is 20-01-2024. Housekeeping Services Tenders in shillong Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

41564799
Tender For Day To Day Repairs And Maintenance Works Of Emergent Nature In Cgmt Office Buildings And Compound At Bsnl Campus, Cto, Shillong For The Year 2023-2024.(Half Yearly)
Open Tender
Indian
Meghalaya
shillong
20-01-2024

Tender Details

Day To Day Repairs And Maintenance Works Of Emergent Nature In Cgmt Office Buildings And Compound At Bsnl Campus, Cto, Shillong For The Year 2023-2024. ( Half Yearly )

Key Value

Document Fees
INR 590 /-
EMD
INR 5560.0 /-
Tender Value
INR 2.77 Lakhs /-

BOQ Items

Name of the work : Day to day repairs and maintenance works of emergent nature in CGMT office buildings and compound at BSNL campus, CTO, Shillong For the year 2023-2024.(Half Yearly)
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
2Trimming of branches of old trees having girthed (measured about height of 1.00 metre above ground level) including making necessary arrangement for climbing holding trunks with rope, trimming of branches and disposal of trimmed branches outside premises/ compound as directed by EIC.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
4Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). a) Sal wood
5Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) a) Kiln seasoned and chemically treated hollock wood i) 30 mm thick shutters
6Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: a) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
7Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :
8300x16 mm
9250x16 mm
10Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : a) 250x10 mm
11Providing and fixing ISi marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete :
12300x20x6 mm
13250x20x6 mm
14Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : a) 125 mm
15Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : a) 90 mm
16Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. a) 250 mm weighing not less than 150 gms.
17Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. a) Twin rubber stopper
18Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. a) 30 mm thick plain PVC door shutters.
19Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
20Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. a) 40 mm thick with 20 mm nominal size stone aggregate
21Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
22Credit to old /damaged wooden flooring and Hard wood
23Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. a) New work (two or more coats) over and including water thinnable priming coat with cement primer.
24Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : a) Water thinnable cement primer.
25Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : a) Old work (one or more coats)
26Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
27Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : a) One or more coats on old work.
28Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : a) One or more coats on old work.
29Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. a) With cement mortar 1:4 (1 cement : 4 fine sand).
30Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
31Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
32Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.
33Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
34Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. a) Orissa pattern W.C Pan of size 580x440 mm
35Credit value for old unserviceable dismantled material a) old unserveciable door shutter
36Credit of Water storage PVC tank with cover.
37Credit of PTMT Bib cock/ Pillar cock 15 mm size./stop cock.
38Credit of Brass spindle of stop/bib cock & Pillar cock-15 mm nominal
39Providing & laying reinforced cement concrete Door Frame of M/s. Pull Cast or equivalent having size 100x50mm of mix 1:1:2(1cement:1fine sand:2graded stone aggregate of 20m nominal size)grade of M25 as per manufactures specification and finished with smooth finsihing
40Providing & fixing 0.50 mm thick Aluminium sheet to toilet door shutters including cutting & folding in required size and shape with necessary screws, nuts etc including removing & refixing the shutter as per direction of Engineer
41Easing of wooden door and windows by removing and refixing including refixing old or missing screws if required as directed by Eng-in-Chagre complete
42a) Doors (area up to 2.50 sqm)
43b) Windows(area up to 1.50sqm)
44c) Cupboards(area up to 2.50sqm)
45d) Pelmets upto 4.0m length
46One time cleaning of premises viz. open ground,plinth protection surrounding building, terrace, canopies, projected portions of a building and roads etc including cleaning rubbish, tree leaves, grasslets, pebbles, domestic waste , plastic carry bags etc disposal of the same outside the compound to Muncipal dust bins as directed by the Engineer-in-Charge.
47Attending leakage from the nahani trap by dismantling the tiles,nahani trap,Cement concrte around it, replacing dismantled nahani trap with new 2 way nahani trap of approved quality 110mm x 75mm dia including providing and fixing 110mm dia PVC pipe in 110mm side of trap 15mm below finished floor level.(approx length 10 to15cm) , jointing of pipe and filling outer space of trap with cement mortor 1:3 (1Cement:3 coarse sand )and finishing top with white cement to match shade of tile etc. all complete as per the direction of Engineer in charge.
48P/F single scaffolding system on the exterior side up to 16 m height made with atleast 100 mm dia Bamboo ballies and maintaining it in a serviceable condition for the required duration and removing it thereafter. The scaffolding frame work shall be stiffened with bracings, runners of 75 mm bamboo and jointing with coir strings, nails etc. connecting with the building etc wherever required making good the walls locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in-charge. (Note: The elevation area of the scaffolding shall be measured for payment purpose and payment shall be made once irrespective of duration of scaffolding for repair works)
49Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
50Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
51Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : a) Of area 3 sq. metres and below
52Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
53Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
54Credit for: Low level PVC flush tanks (10 litres)
55Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
56Credit for Unserviceable G.I.pipe
57a) 15mm dia GI pipe
58b) 20mm dia GI pipe
59c) 25mm dia GI pipe
60d) 40 mm Dia GI Pipe
61e) 50 mm dia GI Pipe
62Credit for taking away CP brass/brass bib cock, stop cock and pillar cocks etc.
63a) 15 mm nominal bore stop/bib,piller cock
64b) 20mm dia stop cock
65c) 25mm dia gate valve
66d) 40mm dia gate valve
67e) 50mm dia wheel valve
68Providing and fixing Sintex or equivalent PVC Cover on over head tank with locking arrangement & as per direction of E.in C.
69Providing & placing R.C.C.1:1.5:3 cover for manholes/gully chamber etc.complete, R.c.c.covers shall have 75mm.thickness,reinforcement should be with 8mm dia.tor steel at 125mm c/cin both direction making the holes in cover to collect surface water & the exposed surfaces should have the smooth finishing and neat cement punning.Cost includes material and labour as above and neccesary centering etc. complete.
70Removing the chokup between sewer manhole to manhole in sewer line of all diameter by puncturig after excavating the trench at the point of blockage,breaking the sewerpipe line,removing the obstacles from pipe repairing the sewerpipe by using jute and cement slurry,refilling of trench after hardening of repaired area etc. complete.
71Cleaning of manhole, gully chamber and interconnected sewer line septic tank by using bammboo/rod for clearing the sewerline, taking out sludge, building, rubbish and other waste materials from the sewer line and flushing with sufficient quantity of water to:
72a) Sewer Manhole
73b) Nahani Trap
74c) Vertical stack of soil pipe/waste pipe
75Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
76Identifying ,treating and rectifing the water leakage from the CGI sheet roofing and providing & fixing nuts and washers of J or L hooks to CGI sheet roofing & providing necessary black putty/bituminous sheet to protect against leakage (area of roof up to 5 Sqm) as directed by the Engineer-in-charge.
77Providing and applying heavy duty reinforced acrylic waterproof coating for terrace NEWCOAT of Dr. Fixit(604) or equivalent ,composed of specially developed highly elastic and resilient acrylic polymers etc. and applied over surface( as per manufacturers specifications Dr Fixit 603 & 604 )in three coats @ 2 Sqm/Litre including a priming coat of Primeseal(603) @ 7 Sqm/Litre etc. complete as directed by the Engineer in charge.
78Engaging helper as and when required for attending day to day maintenance jobs for plumbing job.
79SUPPLY OF MATERIAL AT SITE BRACKET - C. I. a ) For wash basin and sinks.
80Brass Bib cock. a) 15mm nominal dia
81Brass stop cock. a) 15mm dia
82PTMT material
8315mm dia Bib Cock
8415mm dia stop cock
8515mm dia pillar cock
86Grating circular type 100 mm dia
87PTMT BALL COCK
8815mm dia
8920 mm
9025mm
918 mm dia C.P. Brass/ S.S. Jet with flexible tube upto 1 metre long with S.S. tringular plate for Eureopean type W.C.(Hindware/Kingston/Prima/Parko/Marc)
92CPVC Pipes in SDR 11 grade of approved quality
93a) 15 mm nominal outer dia Pipes
94b) 20 mm nominal outer dia Pipes
95c) 25 mm nominal outer dia Pipes
96d) 40 mm nominal outer dia Pipes
97e) 50 mm nominal outer dia Pipes
98CPVC Coupler of approved quality
99a) 15mm nominal dia
100b) 20 mm nominal dia
101c) 25 mm nominal dia
102d) 40 mm nominal dia
103e) 50 mm nominal dia
104CPVC Fittings of approved quality
105i) CPVC Elbow 90°
106a) 15 mm dia
107b) 20mm dia
108c) 25mm dia
109d) 40mm dia
110e) 50mm dia
111CPVC Tee
112a) 15mm dia
113b) 20 mm dia
114c) 25mm dia
115d) 40 mm dia
116e) 50 mm dia
117iii) CPVC Union
118a) 15mm dia
119b) 20mm dia
120e) 50mm dia
121c) 25 mm dia
122d) 40 mm dia
123iv) Male/Female adapters Brass threaded
124a) 15 mm dia
125b) 20mm dia
126c) 25mm dia
127d) 40mm dia
128e) 50mm dia
129v) CPVC Reducer
130a) 25 mm to 15 mm
131c) 40 mm to 15 mm
132e) 40 mm to 25 mm
133f) 50 mm to 25 mm
134g) 50 mm to 40 mm
135Providing CPVC Ball Valve of approved quality as directed by Engineer In-charge.
136a) 15 mm dia
137b) 20 mm dia
138c) 25mm dia
139d) 40 mm dia
140e) 50mm dia
141Providing CPVC Tank Nipple of approved quality as directed by engineer In-charge a) 25mm dia
142Supply of U-PVC pipes (working pressure 4 kg / cm²) Single socketed pipe
143110 mm dia
14475 mm dia
14540 mm dia
146Providing PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
147Bend 87.5°
148110 mm dia
14975 mm dia
15040 mm dia
151Single tee without door
15275 mm dia
15340 mm dia
154110 mm dia
155Providing PVC tank cover for PVC tank
156Providing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
15725 mm dia
15840 mm dia
15950 mm dia
160Providing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
16132 mm dia
16240 mm dia
163Providing spindle for tap,piller cock
16415mm dia bib/stop cock
165Piller cock
166Basin mixer piller cock
167Providing white vitreous china wash basin a) 550x400
168White plastic seat (solid) with lid C.P. brass hinges and rubber buffers
169Unplasticised P.V.C. connection pipe with brass union 45 cm long 15 mm bore
170Providing flushing cistern fittings
171PVC Knob
172Syphon kit for flushing cistern i/c handle
173Providing flushing cistern 10liter capacity
174Providing P.V.C. waste coupling for sink or wash basin including P.V.C. waste fittings complete.
17532 mm dia
17640 mm dia
177Providing polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings .
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail