Tender For Invitation Of Rates For Supply Of Materials And Piece Rated Works At Construction Of Transit Hostel At Dist- Court Campus Distt. Kannauj (U.P.), kannauj-Uttar Pradesh

Uttar Pradesh Jal Nigam-UPJN has published Tender For Invitation Of Rates For Supply Of Materials And Piece Rated Works At Construction Of Transit Hostel At Dist- Court Campus Distt. Kannauj (U.P.). Submission Date for this Tender is 18-01-2024. Springs Tenders in kannauj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41547336
Corrigendum : Tender For Invitation Of Rates For Supply Of Materials And Piece Rated Works At Construction Of Transit Hostel At Dist- Court Campus Distt. Kannauj (U.P.)
Open Tender
Indian
Uttar Pradesh
kannauj
18-01-2024

Tender Details

Invitation Of Rates For Supply Of Materials And Piece Rated Works At Construction Of Transit Hostel At Dist- Court Campus Distt. Kannauj ( U.P. ) As Per Nit And Tender Document , Supplying, Installation And Commissioning Of Amf Start Silent Type 160 Kva Dg Set Comprising Of Suitable Bhpdiesel Engine Directly Coupledto 3 Phase 50 Hz 415 V Alternator Of 160 Kva Rating At 0.8 Power Factor Mounted On A Common Base Frame, Complete In All Respects With All Required Safety Devices, Fittings, Batteries, Accessories, Filters, Residential Type Silencer, Control Panel, Inbuilt Diesel Oil Ms Tank Of 990 Ltrs. Capacity Made Of 2Mm Thick M.S. Sheet Complete With M.S. Fuel Piping, G.M. Gate Valves, Supports, Control Cable Between Generating Set And Control Panel, Exhaust Piping With Asbestos Roping, Antivibration Mounting Pads, First Filling Of Lubricant Oil Totally Enclosed In Air Tight, Dust Proof, Weather Proof, Powder Coated Cubical Type, Sound Proof As Per Cpcb Norms Acoustic Enclosure Made Of 2Mm Thick Crca Sheet With With Heavy Duty Doors, Lockable Arrangement, Sound Proof Insulation With High Density Rock / Mineral Polymer / Fibre Cloth And Perforated Crca Sheets, Suitable To Reduce The Sound Level Upto 75Dba Approx. At A Distance Of 1 Mtrs. As Per Cpcb Norms Amf Panel Incoming-250 Amps Fp Mccb Of 25Ka Breaking Capacity And Contactor Same Rating Complete With Axial Flow Heavy Duty Exhaust Fans For Adequate Ventilation Exhaust Of Hot Air Etc Including Making Of Cement Concrete Foundation Of 1: 2:4 ( 1 Cement 2 Sand And 4, 40Mm Graded Stone Aggregate ) As Per Manufacturer Recommendation Complete As Per Specifications And Conditions As Required. ( The Diesel Engine And Alternator Shall Be So Rated To Deliver The Specified Output At Site Condition Complete With Control Cable Etc. As Required. , Supplying, Installation, Testing And Commissioning Of Grid Interactive Roof Top Solar Photo Voltaic Power Generation System Including Space Frame , Supply And Fixing Of Lift ( 08 Passanger ) , Ht Panelh.T. Vcb ( 11Kv ) ( Located In Meter Room ) Design, Manufacturing, Testing At Works, Supplyof Ht Panelas Per Specification And Comprising Of The Following :- Incomer / Outgoing Panel 630 A Vacuum Circuit Breaker Of 26.3 Ka Ruputuring Capacity At 11 Kv Rated, Totally Enclosed, Air Insulated Metal Clad Housing, Floor Mounting, Vertical Isolation, Vermin Proof, Fully Interlocked Horizontal Drawout Type Having Double Isolation.Manually And Motor Operated, Spring Charged ( Release Closing Mechanism ) Trip Free Type, Triple Pole Truck Mounted Draw Out, Vacuum Circuit Breaker, Incorporating Mechanical As Well As Electrical On / Off Indication.Spring Charge / Discharge Mechanical Indicator.630 Amp Air Insulated But Encapsulated, Pvc Insulated Copper Bus Bars.C.T. Chamber With C.T.S 20 / 5.15 Va Burden For Protection ( Class 5P 10 ) .Following Protection Shall Be Provided:1 Nos Idmt Relay With Instantaneous 2 Nos. Over Currrent ( 50, 50 N ) Element And 1 No.Instantaneous Earth Fault Element ( 50-50N ) . ( O / C Setting 50%-200% And E / F Setting 20%-80% ) All Wiring Necessary For The Above Including Inter-Connections.The Size Of The Conductor Should Not Be Less Than 2.5 Sq. Mm. Copper Wire Where Required.Test Terminal Block, Fuses / 2A Spmcb , Circuit Labels, Set Of Phase, Indication Lamps Etc. As Per Standardpractise As Under. Red - Breaker Close ( On ) Green - Breaker Open ( Off ) Amber - Auto Trip Clear - Trip Circuit Healthy Blue Spring Charged Control :- T-N-C ( Trip, Neutral. Close ) Breaker Control Switch With Indication Arrangement.Terminal Boxes With Single Gland Trifucating Cable Box Suitable For 11 Kv Aluminium Xlpe ( E ) Cable Of Size 3C X 150 Sq. Mm. For Incoming / Outgoingbreaker.Ht Danger Plate. ( As Per Is Specification ) 2 Runs Of 40 X 5 Mm Earth Bus Shall Be Provided For The Full Length Of The Panel.Power Pack, Battery Power Pack Shall Be Rated For Minimum Five ( 5 ) Trippings.For Dc Power One No. Source Selector Switch To Be Incorporated I.E. One Source From Power Pack And Other From Outside.Necessary D.C. Supply Healthy Indication Lamp ( White Colour ) , Switch With Alarm.Surge Supressor As Required. Dc Voltmeter, 0-30 Volt, Digital Type. Ht Panel Switchboard Complete With All Interconnections, Labels, Wiring Etc, Complete As Described Above In Item Nos.A And B And Asper Specifications. , Supply And Fixing Of Co2 Typefire Extinguishers, 4.50 Kg. Capacity ( Isi Marked Is : 2878 & Tac Approved ) Complete With Initial Charges And Wall Bracket, Along With Supply Of All Materials And Labour For Proper Completion Of Work.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jan-2024 Extend Date Date 18-01-2024

Key Value

Document Fees
INR 5900 /-
EMD
INR 650000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Invitation of Rates for Supply of Materials & Piece rated worksat CONST. OF TRANSIT HOSTEL AT DIST. COURT CAMPUS DISTT.KANNAUJ (U.P.) (NIT No. - 23 /E-NIVIDA/10dt.06.01.2024 )
Sl. No. Item Description
1Supplying, Installation and commissioning of AMF start silent type 160 KVA DG set comprising of suitable BHPdiesel engine directly coupledto 3 phase 50 Hz 415 V alternator of 160 KVA rating at 0.8 power factor mounted on a common base frame, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank of 990 ltrs. capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB norms AMF Panel Incoming-250 Amps FP MCCB of 25KA breaking capacity and contactor same rating Complete with axial flow heavy duty exhaust fans for adequate ventilation exhaust of hot air etc including making of cement concrete foundation of 1: 2:4 (1 cement 2 sand and 4, 40mm graded stone aggregate) as per manufacturer recommendation complete as per specifications and conditions as required. (The diesel engine and alternator shall be so rated to deliver the specified output at site condition complete with control cable etc. as required.
2SUPPLYING, INSTALLATION, TESTING AND COMMISSIONING OF GRID INTERACTIVE ROOF TOP SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM INCLUDING SPACE FRAME
3SUPPLY AND FIXING OF LIFT (08 PASSANGER)
4HT PANELH.T. VCB (11KV) ( LOCATED IN METER ROOM)Design, manufacturing, testing at works, supplyof HT Panelas per specification and comprising of the following :- INCOMER/OUTGOING PANEL 630 A Vacuum circuit breaker of 26.3 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, vertical isolation,vermin proof,fully interlocked horizontal drawout type having double isolation.Manually and motor operated, spring charged( release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication.Spring charge/discharge mechanical indicator.630 amp air insulated but encapsulated,PVC insulated Copper bus bars.C.T. chamber with C.T."s 20/5.15 VA burden for protection (class 5P 10).Following protection shall be provided:1 Nos IDMT relay with instantaneous 2 nos. over currrent (50, 50 N) element and 1 no.instantaneous earth fault element(50-50N).(O/C setting 50%-200% and E/F setting 20%-80%)All wiring necessary for the above including inter-connections.The size of the conductor should not be less than 2.5 sq. mm. Copper wire where required.Test terminal block, fuses/2A SPMCB , circuit labels,set of phase, indication lamps etc. as per standardpractise as under. Red - Breaker close (ON)Green - Breaker open (OFF)Amber - auto trip Clear - trip circuit healthy Blue spring charged Control :- T-N-C(Trip, Neutral. Close) breaker control switch with indication arrangement.Terminal boxes with single gland trifucating cable box suitable for 11 KV Aluminium XLPE (E) cable of size 3C x 150 Sq. mm. for incoming/outgoingbreaker.HT Danger Plate.(as per IS specification)2 Runs of 40 X 5 mm earth bus shall be provided for the full length of the panel.Power Pack, Battery power pack shall be rated for minimum five (5) trippings.For DC power one no. source selector switch to be incorporated i.e. one source from power pack and other from outside.Necessary D.C. supply healthy indication lamp (White Colour), switch with alarm.Surge supressor as required. DC Voltmeter, 0-30 Volt, Digital type. HT Panel switchboard complete with all interconnections, labels, wiring etc, complete as described above in item nos.A and B and asper specifications.
5Supply and fixing of CO2 typefire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.
Disclaimer :