Tender For Construction Of Boys Hostel At Hindu College Comprising Of Stilt 5 Floors For 566 Students Including Structural Works, Finishing Works, Internal Water Supply, Sanitary, Storm Water Drainage Electrical Installations Including Fire Alarm , W, Delhi-Delhi

Delhi University has published Tender For Construction Of Boys Hostel At Hindu College Comprising Of Stilt 5 Floors For 566 Students Including Structural Works, Finishing Works, Internal Water Supply, Sanitary, Storm Water Drainage Electrical Installations Including Fire Alarm , W. Submission Date for this Tender is 24-01-2024. Fire Alarm Systems Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41541148
Corrigendum : Tender For Construction Of Boys Hostel At Hindu College Comprising Of Stilt 5 Floors For 566 Students Including Structural Works, Finishing Works, Internal Water Supply, Sanitary, Storm Water Drainage Electrical Installations Including Fire Alarm , W
Open Tender
Indian
Delhi
Delhi
24-01-2024

Tender Details

Construction Of Boys Hostel At Hindu College Comprising Of Stilt 5 Floors For 566 Students Including Structural Works, Finishing Works, Internal Water Supply, Sanitary, Storm Water Drainage Electrical Installations Including Fire Alarm , Wi-Fi And Pa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Jan-2024 EMD Revised Other 24-01-2024

Key Value

Document Fees
INR 5000 /-
EMD
INR 10517000.0 /-
Tender Value
INR 52.58 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OF BOYS HOSTEL AT HINDU COLLEGECOMPRISING OF STILT +5 FLOORS FOR566 STUDENTS INCLUDING STRUCTURAL WORKS, FINISHING WORKS, INTERNAL WATER SUPPLY, SANITARY, STORM WATER DRAINAGE ELECTRICAL INSTALLATIONS INCLUDING FIRE ALARM , WI-FI & PA SYSTEMS AND EXTERNAL DEVELOPMENT WORKS
Sl. No. Item Description
1Part 1 Civil Work
2Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deepand disposal of rubbish, lead upto50 m and liftupto1.5 m. All kinds of soil.
3Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, any width and any area in plan) including getting out and disposal of excavated earth lead upto 200 m and lift upto 1.5 m, as directed by Engineer-in-charge. a) All kinds of soil
4Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to any and lift upto any
5Carriage of earth by mechanical transport including loading, unloading for a lead upto 10.00 Km.
6Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
7Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
8Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil before casting of foundation PCCusing chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
9Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
111:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
121:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
13Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor seven level, excluding the cost of centering, shuttering and finishing :
141:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
151:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
16Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
17Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
18Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specification.
19Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
20Providing and laying in positionready Mixed or site batched design mix cement concrete for reinforced cement concrete work using coarse aggregate and fine aggreate derived from naturalsources , Portland Pozzolana/ordinary Portland/Portland slag cement,admixtares in recommened proportions as perIS: 9103 to accelerate /retard setting of concrete to improve durability and Workabity, without impairing strength, including pumping of concreteto site of laying, curing, Carriage for all leads, but excluding the cost of centering,shuttering, finishing and reinforcement as per direction of theEngineer-in-charge, for the following grades of concrete
21All works upto Plinth level Concrete of M25 grade with minimum cement content of 350 kg /cum
22All works above plinth level upto floor VIIlevel Concrete of M25 grade with minimum cement content of 350 kg /cum
23Providing and laying 75x150mm Precast ferro cement beams
24Extra for R.C.C./ B.M.C/ R.M.C. work above floor V II level for each four floors or part thereof.
25Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
26Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete. Above plinth level. Thermo-Mechanically Treated bars
27Centering and shuttering including strutting, propping etc. and removal of form for :
28Foundation, footing, bases of columns etc. for mass concrete
29Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
30Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
31Columns, Pillars, Piers, Abutments, Posts and Struts- In exposed RCC finish
32Stairs, (excluding landings) except spiral-staircases- in Water proof ply 12 mm thick
33Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
34Edges of slabs and breaks in floors and walls with water proof ply 12 mm thick in exposed RCC finish Under 20 cm wide
35Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
36Weather shade, Chajjas, corbels etc., including edges with water proof ply 12 mm thick in exposed RCC finish
37Extra for shuttering in circular work (20% of respective centering and shuttering items) in exposed RCC finish
38Shelves (Cast in situ)
39Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. Including Grooves/ drip course in Exposed RCC with neat fninishing in RCC itself using aluminum channels etc.
40Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
41Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 200 mm wide.
42Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it"s components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063).Floor Joint of 100 mm gap
43Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). Wall Joint of 100 mm gap
44Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). Roof Joint of 100 mm gap
45Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
46Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor VII level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
47Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : a) Cement mortar 1:4 (1 cement : 4 coarse sand)
48Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor VIIlevel. Cement mortar 1:4 (1 cement :4 coarse sand)
49Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
50Providing and filling AAC blocks including proper watering and compaction in sunken areas all complete as per drawings and as directed by the Engineer-in-chargein-Charge.
51Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor VIIlevel, for each four floors or part thereof by mechanical means.
52Extra for half brick masonry in superstructure, above floor VIIlevel for every four floors or part thereof by mechanical means.
53Brick work with common burnt clay machine moulded F.P.S. (non modular) bricks of class designation 12.5in cement mortar 1:6 (1 cement : 6 coarse sand)in exposedbrick work WITHOUT ANY MORTAR ON FACE OR FRONT EDGES OF BRICKS including making horizontal and vertical grooves 10 mm wide 12 mm deep RECESSED POINTING IN 1:3 Cement Mortar( 1 cement:3 Fine sand mixed with water proofing compound) complete. THE BRICK WORK CAN BE IN FLEMISH BOND, RAT-TRAP BOND OR ENGLISH BOND AS PER DRAWINGS
54From ground level upto plinth level
55Above plinth level upto floor VIIlevel
56Brick work with common burnt clay machine moulded F.P.S. (non modular) bricks of class designation 12.5in cement mortar 1:6 (1 cement : 6 coarse sand)in exposedbrick work WITHOUT ANY MORTAR ON FACE OR FRONT EDGES OF BRICKS including making horizontal and vertical grooves 10 mm wide 12 mm deep RECESSED POINTING IN 1:3 Cement Mortar( 1 cement:3 Fine sand mixed with water proofing compound) complete. THE BRICK WORK CAN BE IN FLEMISH BOND, RAT-TRAP BOND OR ENGLISH BOND AS PER DRAWINGS- 75 MM THICK ONLY THICKNESS AS CLADDING ON FACE OF RCC MEMBERS
57Brick work with common burnt clay machine moulded F.P.S. (non modular) bricks of class designation 12.5in cement mortar 1:6 (1 cement : 6 coarse sand)in exposedbrick work WITHOUT ANY MORTAR ON FACE OR FRONT EDGES OF BRICKS including making horizontal and vertical grooves 10 mm wide 12 mm deep RECESSED POINTING IN 1:3 Cement Mortar( 1 cement:3 Fine sand mixed with water proofing compound) complete. THE BRICK WORK CAN BE IN FLEMISH BOND, RAT-TRAP BOND OR ENGLISH BOND AS PER DRAWINGS--MAKING BRICK JALIS AS PER DRAWINGS . INDICATIVE SKETCH PROVIDED IN ATTACHED DRAWINGS.
58Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm
59Providing and fixing 25 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Kota stone window Sill
60Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
61Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
62Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
63Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
64Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
65Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
66Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
67Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
68Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm
69Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
70Providing and fixing Stainless steel satin finish SS 304 grade Sliding Door bolts 250x16 mm for wooden doors of approved make and model all complete as per the directions of Engineer-in-charge 250x16 mm
71Providing and fixing Stainless steel satin finish SS 304 grade Tower Bolts SS screws for wooden doors of approved make and model all complete as per the directions of Engineer-in-charge
72300x10 mm
73200x10 mm
74Providing and fixing Door closer with link arm satin finish with SS screws for wooden doors of width upto 950mm of approved make and model all complete as per the directions of Engineer-in-charge
75Providing and fixing Stainless steel SS 304 grade satin finish wall mounted door stopper of 75mm length with SS screws of approved make and model all complete as per directions of Engineer-in-charge
76Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
77Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers with SS 304 body. Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre).
78Fixed window / ventilator with mullion / transom Using R1 series with frame (33 mm & above) x (35 mm & above) & mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre
79Using R3 series with frame (55 mm & above) x (45 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 2.5 metre
80Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles.Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre).
81Casement cum fixed panel window having one single casement panel & fixed panel with S.S 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre; each openable shutter upto 0.8m width)
82Using R3 series with frame (55 mm & above) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 1.8 metre: each openable shutter upto 0.8m width)
83Casement cum fixed panel window having single casement panel at both ends & middle fixed panel with S.S 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) (60 mm & above). (Height upto 1.2 metre; each openable shutter upto 0.8m width)
84Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/cum. The frame will have a provision of G.I. anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge . (Cost of SS ball bearing hinges is excluded).
85Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes fire rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately).
86Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
87Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
88Providing and fixing in position aluminumdoor fully panelled with 12mm thk. Novapan BSL and made up of extruded and anodised aluminium sections of approved make and of size 63.5 mm x 38.10 mm x 2.0 mm thk (wt. 1.054 kg/Rm) for outer frame, 47.62 mm x 10.16 mm x 1.74 mm thk (wt. 0.881kg/Rm) for top rail, 95.25 mm x 25.40 mm x 2.0 mm thk(wt. 1.519 kg/Rm) for bottom rail, 25.0 mm x 44.45 mm x 2.40 mm thk (wt. 0.918 kg/Rm) for lock rail, 47.62 mm x 44.45 mm x 1.8 mm thk (wt. 0.943kg/Rm) for shutter vertical hinges side, 47.62 mm x 44.45 mm x 1.95 mm thk (wt. 0.936 kg/Rm) shutter vertical latch side, clip weighing 0.097 kg/Rm including neoprene gasket, fixtures, fastenings and accesories like hinges, locking arrangement, door closer, tower bolts, handle etc. complete as directed by Engineer In Charge. (Note: anodic film must not be less than 15 microns i.e. AC-15 as per IS, the anodising must be scaleted by keeping the anodized section in boiling deanodized water for a period of one hour)
89Door (1100x2100)
90Door (750x2100)
91Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
9210 x 80 mm
9310 x 120 mm
94Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
95Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
96Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
97Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
98Providing and fixing precoated Galvalume (PPGL) profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
99Providing and fixing Bug screen for external door and window
100Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
101Gutter (600 mm over all girth)
102Flashings/ Aprons.( Upto 600 mm)
103North light curves metre
104Barge board (Upto 300 mm)
105Crimp curve sqm
106Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
107Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, dado, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
108Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
109Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
110Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
111Extra above item 11.26 for Providing and fixing kota stone with rubbing and mirror polishing on Top of Parapets, Top of cills including, vertical face of tops and cills including making bird beak/ offset joint and providing weather groove/ drip course on the stone edge, stone area to be measured on actual plan or elevation measurements only without any rounding off.
112Providing weather groove/ drip course on the edge of Kota stone as per any design.
113Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 2.00 metre.
114Providing and laying rectified Glazed Ceramic floor tiles of size 600x600 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
115Providing and fixing Ist quality Ceramic Glazed wall tiles size 600x1200mmconforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
116Extra for fixing tiles in any BOQ item with 4 mm wide groove using spacers on vertical or horizonral surfaces, complete with white cement,pigment and specified Grout.
117Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
118Providing and fiixng 18 mm thick polished granite stone in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3(1 cement : 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete.
119Providing and laying Lapato finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
120Providing and fiixng 18 mm thick Lapato finish granite stone in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3(1 cement : 3 coarse sand ) and jointed with white cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete.
121Providing and fiixing Delhi quartz stone cladding fixed on 20 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with grey cement slurry @ 3.3 kg/sqm including pointing with grey cement slurry admixed with pigment of matching shade including pointing with 1:3 Cement sand mortaretc. all complete in approved pattern as per drawings, and as directed by the Engineer-in-Charge.
122Extra above item 8.11 for Providing and fixing 18 mm th. Granite stone with rubbing and mirror polishing on Top of Parapets, Top of cills including, vertical face of tops and cills including making bird beak/ offset joint and providing weather groove/ drip course on the stone edge, stone area to be measured on actual plan or elevation measurements only without any rounding off.
123Providing weather groove/ drip course on the edge of 18 mm th. Granite stone as per any design.
124Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
125Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
126Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
127Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. 1:4 (1 cement: 4 coarse sand
12818 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
129Finishinginterior and specified exterior wall/ RCC surfaceswithApex ultima water based paint of Asianpaint brand-2coats on one coatoftrucare acrylic wall putty Asian paint brand - complete as per manufacturer"s specifications, applying additional coats wherever required, to achieve even shade and colour. Two or more coats on new work
130Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
131Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
132Finishinginterior and specified exterior wall/ RCC surfaceswithApex ultima water based paint of Asianpaintbrand- 2 coatson one coat of trucare exterior wall primer Asian paint brand - complete as per manufacturer"s specifications New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
133Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
134Polishing wooden surface with melamine polish after sanding with sand paper no.180 , then 320, then applying 2coats of wood tech epoxy insulator then dent filling withwoodtechfillerthenstainingwood techwoodstainsinteriorsbyspraying and application of Melamyne. Then applying wood tech PU luxury wood finish coating of Asian paints brand
135Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
136Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
137For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
138For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
139Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides
140Providing and fixing 6mm thick toughened glass in Doors, windows and Ventilators including sealing with EPDM / Neoprene gasket all complete as per the architectural drawings and the directions of engineer-in-charge
141Providing and fixing 8mm thick toughened glass in Doors, windows and Ventilators including sealing with EPDM / Neoprene gasket all complete as per the architectural drawings and the directions of engineer-in-charge
142Providing and fixing Louver with 6mm thick frosted glass in windows and Ventilators including sealing with EPDM / Neoprene gasket all complete as per the architectural drawings and the directions of engineer-in-charge
143Providing and fixing pre sealed Double glass panes 8mm glass +25 mm argon filled+8 mm glass ( Insulated Glass units ) as per ASTM E2190-19 Standard Specification for Insulating Glass Unit Performance and Evaluation
144Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
145Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
146Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar
147Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Powder coated minimum thickness 50 micron aluminium
148Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-incharge Powder coated minimum thickness 50 micron aluminium
149Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
150Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. "All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
151Providing and fixing Metal sheet on terrace lvl
152Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
153Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
154Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
155Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
156Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
157Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
158Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
159Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately
160The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025
1611. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
162Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement
163Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- inCharge.
164Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.
165Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- inCharge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
166Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
167Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineerin- Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
168Providing and fixing HDPE Sheet 500 micron
169Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 350 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately).
170Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
17162 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
172Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
173Part-2 water supply, storm water drinage, sewerage and plumbing
174Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for alldepthincluding getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m.All kinds of soil.pipes cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia
175Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
176Providing and placing on terrace (at all floor levels)polyethylenewater storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
177Providingandfixingsquare-mouthS.W.gullytrap classSP1completewithC.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be notless than 2.70 kgas perstandard design :150 x 100 mmsize P type. With sewer bricks conforming to IS : 4885
178Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III): 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4coarse sand(zone-III): 8gradedstoneaggregate40mmnominal size), inside plastering 12mm thick with cement mortar 1:3 (1ement: 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement :2 coarse sand :4 Graded stone aggregate nominal size ) finished with a floating coat of neat cement complete as per standard design inside size 90x80 cm and 45 cm deep including C.I. cover with frame (Light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 KG ( weight of Cover 23 kg and weight of frame 15 Kg): With common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
179Extra for depth of Manholes Size 90x80 cm With common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
180Constructing brick masonry road gully chamber 50x45x60cmwithbricksin cementmortar 1:4 (1 cement:4coarsesand)including500x450mm pre-cast R.C.C.horizontalgratingwithframe complete as per standard design : bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical gratingcomplete as per standard design : 19.28.1 With common burnt clayF.P.S. (nonmodular) bricks of class designation7.5 WithcommonburntclayF.P.S. (non modular) bricks of class designation 7.5
181P/L NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of (1:2):
182250 mm dia RCC pipe
183300 mm dia RCC Pipe
184Providing and fixing on wall face unplasticised Rigid PVC rain water pipesconforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes. 160mm diameter
185Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conformingto IS:13592 Type A, including jointing with seal ring conforming to IS:5382,leaving10mmgapfor thermal expansion.
186Single tee without door 160x160x160 mm
187Bend 87.5° 160 mm bend
188Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes, havingthermalstability for hot & cold water supply including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings including unions and reducers with one step CPVC solvent cement and the costofcuttingchasesandmakinggoodthe same including testing of joints complete as per direction of Engineer in Charge . concealed work including cuttingchasesandmakinggood the walls etc.,
18920 mm nominal outer dia .Pipes.
19025 mm nominal outer dia .Pipes.
19132 mm nominal outer dia .Pipes.
19250 mm nominal outer dia .Pipes.-From tank to shaft
193SITC of Solar Geyser - 1000 LPD, no of tubes 54, total height after fitting 6"3", inner tank in SS304, tank insulation with PUF, back up electrical heater 8KW or 2 nos. 4 KW outer tank cover GI powder coated.Including 3 years warantee
194SITC of Solar Geyser - 100 LPD, no of tubes 8, maximum height after fitting 6"3", inner tank in SS304, tank insulation with PUF, back up electrical heater 2KW or 2 nos.14 KW outer tank cover GI powder coated.Including 3 years warantee
195Providingandfixingballvalve(brass)ofapproved quality, High or low pressure, with plastic floats complete :15 mm nominal bore
196P/F CPVC ball valve (gate valve) of approved make in CPVC pipes i/c cutting, chasing of, making it good and making all complete as per the directions of Engineer- in-charge.
19750mm nominal bore
19832mm nominal bore
19925 mm nominal bore
20020 mm nominal bore
201Providingand fixingwaterclosets-Anglo Indian, S type,Essco -Jaquar brand ECS-WHT-355SNPP Size: 475x575x395 mm, S Trap . Item includes all accessories, all type of piping,white cement, sundries
202Providingand fixing Hindware Dual flush cistern Catalogue no. 516366 Size 38.5 × 12.2 × 40.5 cm,Item includes all accessories, all type of piping,white cement, sundries
203Providingandfixing with all sundries healthfaucet(handshower )JaquarbrandRange:Allied Code :ALD-CHR-573 Description :Hand Shower (Health Faucet) with 8mm Dia 1.2 Meter Long Flexible Tube and Wall Hook.. Item includes all accessories, all type of piping,white cement, sundries
204ProvidingandfixingJaquarWashBasinAriaARS WHT39903Type:TableTop Colour:White Shape:RectangleDimensions:700x435x135mm Item includesall accessories,piping,white cement, sundries , brackets etc. Complete
205ProvidingandfixingP.V.C.wastepipeforsinkor washbasinincludingP.V.C. waste fittings complete. Flexible pipe 32 mm dia Item includes all accessories, all type of piping,white cement, sundries
206Providing andfixing 600x450 mmbevelededge mirrorof superiorglass (of approvedquality) complete with 6 mm thick hard board ground fixedtowooden cleats with C.P. brass screws and washers complete.
207Providing and fixing Jaquar Artize Soap Dish Holder Brass Chrome Plated Range :KubixPrimeCode:AKP-CHR-35731PDescription :Soap Dish Holder . Item includes all accessories, all type of piping,white cement, sundries
208Providing andfixing C.P.brassBibCock Jaquar brand Range :Aria Code :ARI- CHR-39037 Description :Bib Cock with Wall Flange. Item includes all accessories, all type of piping,white cement, sundries
209Providing and fixingJaquar brand C.P. Long Body Bib Cock with Wall Flange, CODE : COP-CHR-107PM. Item includes all accessories, all type of piping,white cement, sundries
210Providing and fixing CP Grating Square Grating, Size: 5"X5" SS304BrandOnida Shape Square Material Stainless Steel Size 5" x 5"/6" x 6" Cat No 60/3025 Model No 5120/5121 125 mm nominal dia with 25 mm waste hole/without hole. Item includes all accessories, all type of piping,white cement, sundries
211Providing and fixingJaquar brand double Coat hook ACN-CHR-1161NItem includes all accessories, all type of piping,white cement, sundries
212Providing and fixing Jaquar brand ACN-1121N Towel Ring Square. Item includes all accessories, all type of piping,white cement, sundries
213Providing and fixing Sink pillar taps with swivel outputas per CAT no. SOL-6357 GE.. Item includes all accessories, all type of piping,white cement, sundries
214Angular stop cock Jaquar brand, Model No : Angular Stop Cock with Wall Flange, CQT-CHR-23059. Item includes all accessories, all type of piping,white cement, sundries
215Floor trap Brand Chilly model no. Chilly-CCTL-SMHC-150. Item includes all accessories, all type of piping,white cement, sundries
216Push Tap for urinal Jaquar, Model No : Pressmatic PRS077 G Urinal Valve with Auto Closing system with 65 mm Extension Body. Item includes all accessories, all type of piping,white cement, sundries
217white viterous china large flat back / half stall urinal Jaquar-URS-WHT- 0706) (Make For Push Tap for Urinal : Jaquar, Model No : Pressmatic PRS077 G Urinal Valve with Auto Closing system with 65 mm Extension Body. Item includes all accessories, all type of piping,white cement, sundries Floor drain Fixture included in PVC piping
218Overhead shower Brand Jaquar model no.?OHS-CHR-1759180 mm dia round overhead shower alongwith shower arm and flange etc. Item includes all accessories, all type of piping,white cement, sundries
219Concealed stop cock Jaquar Regular Concealed Stop Cock 20MM-089 ALD-CHR-089 and Jaquar exterior partFlr-chr-5083nk. Item includes all accessories, all type of piping,white cement, sundries
220P/FCPVCunionapprovedmakeCPVCpipesi/c cutting and making all complete as per the directions of Engineer-in-charge.. Item includes all accessories, all type of piping,white cement, sundries
22150 mm nominal bore
22232 mm nominal bore
223Providingandfixingsoil,wasteandventVERTICAL pipes in uPVC SWR pipings, working pressure 6.0 kg/ sq.cm.including all fittings , jointing (all types of traps, floor drains, bends, coupling, offsets, tees all of them with or without doors) . Length shall be measured from GT , Manhole to Cowl or Horizontal termination pointwithout any extra allowance for fittings. . Item includes all types of chasing , core cutting, all accessories, all type of piping,white cement, sundries
224110 mm Outer dia
225160 mm Outer dia
226Providingandfixingsoil,wasteandventHORIZONTAL SLUNG pipes in uPVC SWR pipings , working pressure 6.0 kg / sq.cm including all fittings, jointing(all types of traps, floor drains,bends, coupling, offsets, tees all of them with or without doors) . The rates are inclusive of required Core cuttings in RCC members, chasing of all types, water proofing with 1:3 Cement sand Mortar with FOSROC water proofing Compund as / manufacturer"s specificationsof all thickness and dia. Length shall be measured from Start to End in a single horizontal linewithout any extra allowance for fittings. 110 mm Outer dia
227Part-3 Electrical Combinded
228Main Panel(All Block) INCOMER 1 No. 300A 4P MCCB ,36 kA breaking capacity with thermal release and adjustable setting and with rotary handle.with ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 set of ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB BUS-BAR 1 Set of 450A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS1 Nos.200A FP MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle 3 Nos.160A FP MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle 6 Nos.63A FP MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle NOTE :- All starters shall have ON & OFF push button &suitable rating of contractor and overload relays Supplying,Receiving, fixing, testing & commissioning ofabove described Panel
229SUB Main Panel(Audi. Block) INCOMER 1 No. 200A 4P MCCB ,36 kA breaking capacity with thermal release and adjustable setting and with rotary handle.with ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 set of ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB BUS-BAR 1 Set of 250A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 18 Nos.63A TPN MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle NOTE :- All starters shall have ON & OFF push button &suitable rating of contractor and overload relays Supplying,Receiving, fixing, testing & commissioning ofabove described Panel
230Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
231Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.:Group A
232Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
233Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
234Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
235Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
2362 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2374x 10 sqmm+ 2x 6 sqmm earth wire
238Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in case of recessed conduit as required.
23925 mm dia.
24032 mm dia.
241Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing6 pin5/6 & 15/16 Amp modular socket outlet and 15/16 A modularswitch, connection etc. as required.
242Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
243Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4+12),Double door
244Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4+24),Double door
245Supplying & fixing 6 amps to 32 amps rating 240/415 volts C curveMiniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
246Supply & fixing of single poleblanking plate in the existing MCB DB complete etc. as required
247Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
248Supplying and fixing of following rating four pole 415 VMCCB in the existing MCCB DB complete with connections ,testing and commissioning etc as required.
24963 amps
250100 amps
251Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
252Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, as required.
253Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
254Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as requied.
255Supply, Installation, Testing and Commissioning of 10 W LED Bulk head Light- Supply of 10W LED bulkhead Surface mounted IP65 bulkhead LED fixture made up ofpressure die cast aluminum housing with integrated power supply unit, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =90 lumens/watt with Minimum system Lumens 900,Life of LED : 50000 burning Hrs. @ L70B50 Lumen maintenance, cool white color temperature (SDCM<5), CRI >80, PF >0.95 & THD<10%, an operating Voltage Range of 150 - 260 VAC.Minimum Internal Surge Protection 2.5KV As Trilux Optima IND G3 900-857 ET or equvalient.
256Supply, Installation, Testing and Commissioning of 12W Surface Mounted LED circular Downlighter - Supply of Surface Mounted LED Downlight with cylindrical construction, Housing Dia 160 mm, height 110 mm, Luminaire luminous flux 1320 Lm, Maximum system Power 12W, Luminous efficiency of 110 Lm/W. CRI >80. Life of fixture 50000 hrs@ L70 Lumen maintenance, CCT 5700K, CRI >80, PF >0.95, and suitable for 230V AC, 50Hz. supply,Internal Surge Protection= 2.5KV. The fixture should comply with the parameters as per IS10322 and IEC60598,EMC / EMI compliance, and LED driver shall be SELV & BIS registered & luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer as Trilux Ambiella D Plus G4 Surface.
257Supply, installing, testing & commissioning of Decorative Wall Light with 2 LT Ivory Fabric shade with 3W LED mild steel & Brass with Chrome finish, Fixture Height 405mm, Size (LXWXH) 155 X 280 X 405 mm and E14 base 7w Bulb or Eqivalent as per direction of E/I.
258Supplyinstalling, testing & commissioning of LED 4ft Batten with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70B50. The luminaire should have a color temperature of 6500K/4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. It should have a surge protection of 2.5kV. The luminaire housing should made of Polycarbonate housing with a diffuser.
259Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
260Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
261Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
262Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
263Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
264Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
265Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
266Supply, Installation, Testing & Commissioning ofIndoor Access Point solution should have integrated dynamic packet capture, WIPS, detection of rouge and honeypot Access Point detection, able to create WxLAN policies and the cloud controller should be scalable to handle around 5000 APs or more in future. Should be able to extend API to integrate with other systems as well. AP indoor 4x4 with 802.11 a/b/g/n/ac support. The solution should be artificial intelligence based self healing soltion.The solution should support Location Based services via Bluetooth low energy and should also support Asset Tracking if required in future without any change in Hardware. Should support upto 16 SSIDs per AP. Must be able to limit per SSID or per user based uplink or downlink bandwidth , as per detailed specification ofmanagement controller.
267Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required (for Connectivity of Hub room to End Point)
268Supply, Installation, Testing and Commissiong ofCAT6 information outlet (I/O) for camera at user end.
269Supply, Installation, Testing and Commissiong ofloaded 24 port CAT6jack panel for CAT6 cable termination at rack end.
270Supply, Installation, Testing and Commissiong of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity.
271Supply, Installation, Testing and Commissiong of 1, 2 and 4 port face plate white for I/O fixing at user side.
272Supply, Installation, Testing & Commissioning of 3 MP Bullet camera ,ONVIF profile S ,G & T . UL , CE , FCC Certified ,1/2.8” Progressive Scan CMOS ,2.7 mm to 12 mm motorized varifocal lens , Quad stream with each stream supportH.265+ compression simultaneously ,min illumination : 0.01 Lux @ (F1.2,AGC ON), 0 Lux with IR , Shutter speed :1 / 5s ~ 1 / 100,000 s ,120 dB WDR , Compression : H.265+ ,H.265 ,H.264+H.264 .SD card support , Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 fps@5MP , Edge analytics : line crossing , perimeter intrusion ,Face detection (deep learning) , pedestrian detection ,cross counting , stationary object , In built IR LED , IR Distance upto 50 meters , IP 67 , IK 10 housing , POE
273Supply, Installation, Testing & Commissioning of 32 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out :16chin / 4chout , 1 X RJ45 Ethernet , iOS smartphone support , 8 HDD support, each HDD slot support upto 8 TB HDD , RAID support , 1x3.0 USBfor backup /upgrade , 2x 2.0 USB for mouse, Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000,A.I maximum captured quantity200,000.UL,CE,FCC certified
274Supply, Installation, Testing and Commissiong of 6TB Surviellance Hard Disk.
275Supply, Installation, Testing and Commissiong ofFull HD 42" LED Professional Display Panel.
276Supply, Installation, Testing & Commissioning of of Access Switch 24 Port POE+ Access Switches with switching capacity of 56 Gbps, forwarding performance 10 Mpps, having8 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 370W and 2x 1G SFP+ uplink ports
277Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia.
278Supply, Installation, Testing and Commissiong of intelligent analog addressable photothermal detector complete with mounting base complete as required. Below False Ceiling
279Supplying, installation, testing & commissioning of addressable manual call point complete as required.
280Hooter cum strobe Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
281FIRE ALARM CONTROL PANEL Supplying, installation, testing & commissioning of micro processor basedintelligentaddressablemainfire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel.
282Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
283Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
284SPEAKERS Supply of 1.5/3/6W metal box ceiling/wall speakers complete as required.
285DIGITAL AMPLIFIERS Supply of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 250 Watts
286Supply of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
287Speaker cable Two pair, 2-core, 1.5 sqmm
288Supplying, installation, testing & commissioning of. Speaker cable Two pair, 2-core, 1.5 sqmm
289SWITCH CONTROL LIGHT POINTS Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(For Concealed Wiring) Group A
290Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
291Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
292Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
293Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
2942 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2952x 6 sqmm+ 1x 6 sqmm earth wire
296Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing6 pin5/6 & 15/16 Amp modular socket outlet and 15/16 A modularswitch, connection etc. as required.
297Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
298Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4+18),Double door
299Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, double door
300Supplying & fixing 6 amps to 32 amps rating 240/415 volts C curveMiniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
301Supply & fixing of single poleblanking plate in the existing MCB DB complete etc. as required
302Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
303Supplying and fixing of following rating four pole 415 VMCCB in the existing MCCB DB complete with connections ,testing and commissioning etc as required. 63 amps
304Supply, installing, testing & commissioning of Track light 24W LED.
305Supplyinstalling, testing & commissioning of LED 4ft Batten with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70B50. The luminaire should have a color temperature of 6500K/4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. It should have a surge protection of 2.5kV. The luminaire housing should made of Polycarbonate housing with a diffuser.
306Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
307Main Panel(Hostel Block) INCOMER 1 No. 160A 4P MCCB ,36 kA breaking capacity with thermal release and adjustable setting and with rotary handle.with ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 set of ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB BUS-BAR 1 Set of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 6 Nos.63A TPN MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle 1Nos.100A TPN MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle NOTE :- All starters shall have ON & OFF push button &suitable rating of contractor and overload relays Supplying,Receiving, fixing, testing & commissioning ofabove described Panel
308SWITCH CONTROL LIGHT POINTSWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(For Concealed Wiring) Group A (Hostels)
309Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
310Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
311Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
312Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
3132 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3142x 6 sqmm+ 1x 6 sqmm earth wire
3154x 10 sqmm+ 2x 6 sqmm earth wire
316Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in case of recessed conduit as required.
31725 mm dia.
31832 mm dia.
319Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing6 pin5/6 & 15/16 Amp modular socket outlet and 15/16 A modularswitch, connection etc. as required.
320Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
321Supplying & fixing of 1 OR 2 modual(75mm x 75mm) GI box along with modular base and cover plate including supplying and fixing 25 Amp. modular switch in recess etc. as required. (FOR MASTER SWITCH OF LIGHT & POWER CIRCUITS-ALL ROOMS)
322Supplying & fixing Single Phase Digital Multi-Function Electrical Energy meter with GI box along with modular base and cover plate complete all respect.
323Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, double door
324Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4+24),Double door
325Supplying & fixing 6 amps to 32 amps rating 240/415 volts C curveMiniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
326Supply & fixing of single poleblanking plate in the existing MCB DB complete etc. as required
327Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
328Supplying and fixing of following rating four pole 415 VMCCB in the existing MCCB DB complete with connections ,testing and commissioning etc as required. 63 amps
329Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
330Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, as required.
331Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
332Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as requied.
333Supply, Installation, Testing and Commissioning of 10 W LED Bulk head Light- Supply of 10W LED bulkhead Surface mounted IP65 bulkhead LED fixture made up ofpressure die cast aluminum housing with integrated power supply unit, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =90 lumens/watt with Minimum system Lumens 900,Life of LED : 50000 burning Hrs. @ L70B50 Lumen maintenance, cool white color temperature (SDCM<5), CRI >80, PF >0.95 & THD<10%, an operating Voltage Range of 150 - 260 VAC.Minimum Internal Surge Protection 2.5KV As Trilux Optima IND G3 900-857 ET or equvalient.
334Supply, Installation, Testing and Commissioning of 12W Surface Mounted LED circular Downlighter - Supply of Surface Mounted LED Downlight with cylindrical construction, Housing Dia 160 mm, height 110 mm, Luminaire luminous flux 1320 Lm, Maximum system Power 12W, Luminous efficiency of 110 Lm/W. CRI >80. Life of fixture 50000 hrs@ L70 Lumen maintenance, CCT 5700K, CRI >80, PF >0.95, and suitable for 230V AC, 50Hz. supply,Internal Surge Protection= 2.5KV. The fixture should comply with the parameters as per IS10322 and IEC60598,EMC / EMI compliance, and LED driver shall be SELV & BIS registered & luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer as Trilux Ambiella D Plus G4 Surface.
335Supply, installing, testing & commissioning of Decorative Wall Light with 2 LT Ivory Fabric shade with 3W LED mild steel & Brass with Chrome finish, Fixture Height 405mm, Size (LXWXH) 155 X 280 X 405 mm and E14 base 7w Bulb or Eqivalent as per direction of E/I.
336Supplyinstalling, testing & commissioning of LED 4ft Batten with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70B50. The luminaire should have a color temperature of 6500K/4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. It should have a surge protection of 2.5kV. The luminaire housing should made of Polycarbonate housing with a diffuser.
337Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
338Supply, Installation, Testing and Commissioning of300 mm dia Domestic Exhaust Fan
339Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
340Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
341Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
342Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
343Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
344Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
345Supply, Installation, Testing & Commissioning ofIndoor Access Point solution should have integrated dynamic packet capture, WIPS, detection of rouge and honeypot Access Point detection, able to create WxLAN policies and the cloud controller should be scalable to handle around 5000 APs or more in future. Should be able to extend API to integrate with other systems as well. AP indoor 4x4 with 802.11 a/b/g/n/ac support. The solution should be artificial intelligence based self healing soltion.The solution should support Location Based services via Bluetooth low energy and should also support Asset Tracking if required in future without any change in Hardware. Should support upto 16 SSIDs per AP. Must be able to limit per SSID or per user based uplink or downlink bandwidth , as per detailed specification ofmanagement controller.
346Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required (for Connectivity of Hub room to End Point)
347Supply, Installation, Testing and Commissiong ofCAT6 information outlet (I/O) for camera at user end.
348Supply, Installation, Testing and Commissiong ofloaded 24 port CAT6jack panel for CAT6 cable termination at rack end.
349Supply, Installation, Testing and Commissiong of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity.
350Supply, Installation, Testing and Commissiong of 1, 2 and 4 port face plate white for I/O fixing at user side.
351Supply, Installation, Testing & Commissioning of 3 MP Bullet camera ,ONVIF profile S ,G & T . UL , CE , FCC Certified ,1/2.8” Progressive Scan CMOS ,2.7 mm to 12 mm motorized varifocal lens , Quad stream with each stream supportH.265+ compression simultaneously ,min illumination : 0.01 Lux @ (F1.2,AGC ON), 0 Lux with IR , Shutter speed :1 / 5s ~ 1 / 100,000 s ,120 dB WDR , Compression : H.265+ ,H.265 ,H.264+H.264 .SD card support , Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 fps@5MP , Edge analytics : line crossing , perimeter intrusion ,Face detection (deep learning) , pedestrian detection ,cross counting , stationary object , In built IR LED , IR Distance upto 50 meters , IP 67 , IK 10 housing , POE
352Supply, Installation, Testing & Commissioning of 32 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out :16chin / 4chout , 1 X RJ45 Ethernet , iOS smartphone support , 8 HDD support, each HDD slot support upto 8 TB HDD , RAID support , 1x3.0 USBfor backup /upgrade , 2x 2.0 USB for mouse, Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000,A.I maximum captured quantity200,000.UL,CE,FCC certified
353Supply, Installation, Testing and Commissiong of 6TB Surviellance Hard Disk.
354Supply, Installation, Testing and Commissiong ofFull HD 42" LED Professional Display Panel.
355Supply, Installation, Testing & Commissioning of of Access Switch 24 Port POE+ Access Switches with switching capacity of 56 Gbps, forwarding performance 10 Mpps, having8 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 370W and 2x 1G SFP+ uplink ports
356Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia.
357Supply, Installation, Testing and Commissiong of intelligent analog addressable photothermal detector complete with mounting base complete as required. Below False Ceiling
358Supplying, installation, testing & commissioning of addressable manual call point complete as required.
359Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
360Supplying, installation, testing & commissioning of micro processor basedintelligentaddressablemainfire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel.
361Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
362Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
363Supply of 1.5/3/6W metal box ceiling/wall speakers complete as required.
364Supply of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 250 Watts
365Supply of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Two pair, 2-core, 1.5 sqmm
366Main Panel INCOMER 1 No. 63A DP MCB ,25 kA breaking capacity with thermal release and adjustable setting and with rotary handle.with ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 set of ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB BUS-BAR 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 6 Nos.32A DP MCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle NOTE :- All starters shall have ON & OFF push button &suitable rating of contractor and overload relays Supplying,Receiving, fixing, testing & commissioning ofabove described Panel
367Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(For Concealed Wiring) Group A
368Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
369Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
370Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
371Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
3722 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3732x 6 sqmm+ 1x 6 sqmm earth wire
3744x 10 sqmm+ 2x 6 sqmm earth wire
375Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing6 pin5/6 & 15/16 Amp modular socket outlet and 15/16 A modularswitch, connection etc. as required.
376Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
377Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4+12),Double door
378Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, double door
379Supplying & fixing 6 amps to 32 amps rating 240/415 volts C curveMiniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
380Supply & fixing of single poleblanking plate in the existing MCB DB complete etc. as required
381Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
382Supplying and fixing of following rating four pole 415 VMCCB in the existing MCCB DB complete with connections ,testing and commissioning etc as required. 63 amps
383Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
384Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, as required.
385Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
386Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as requied.
387Supply, Installation, Testing and Commissioning of 10 W LED Bulk head Light- Supply of 10W LED bulkhead Surface mounted IP65 bulkhead LED fixture made up ofpressure die cast aluminum housing with integrated power supply unit, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) =90 lumens/watt with Minimum system Lumens 900,Life of LED : 50000 burning Hrs. @ L70B50 Lumen maintenance, cool white color temperature (SDCM<5), CRI >80, PF >0.95 & THD<10%, an operating Voltage Range of 150 - 260 VAC.Minimum Internal Surge Protection 2.5KV As Trilux Optima IND G3 900-857 ET or equvalient.
388Supply, Installation, Testing and Commissioning of 12W Surface Mounted LED circular Downlighter - Supply of Surface Mounted LED Downlight with cylindrical construction, Housing Dia 160 mm, height 110 mm, Luminaire luminous flux 1320 Lm, Maximum system Power 12W, Luminous efficiency of 110 Lm/W. CRI >80. Life of fixture 50000 hrs@ L70 Lumen maintenance, CCT 5700K, CRI >80, PF >0.95, and suitable for 230V AC, 50Hz. supply,Internal Surge Protection= 2.5KV. The fixture should comply with the parameters as per IS10322 and IEC60598,EMC / EMI compliance, and LED driver shall be SELV & BIS registered & luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer as Trilux Ambiella D Plus G4 Surface.
389Supply, installing, testing & commissioning of Decorative Wall Light with 2 LT Ivory Fabric shade with 3W LED mild steel & Brass with Chrome finish, Fixture Height 405mm, Size (LXWXH) 155 X 280 X 405 mm and E14 base 7w Bulb or Eqivalent as per direction of E/I.
390Supplyinstalling, testing & commissioning of LED 4ft Batten with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70B50. The luminaire should have a color temperature of 6500K/4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. It should have a surge protection of 2.5kV. The luminaire housing should made of Polycarbonate housing with a diffuser.
391Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
392Supply, Installation, Testing and Commissioning of300 mm dia Domestic Exhaust Fan
393Part-4 FIRE FIGHTING WORKS
394Supplying, installation, testing and commissioning of electric driven terrace Booster pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump): (a) Horizontal type, Singlestage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC,synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 900 lpm at 35 m Head
395Providing, fixing, testing and commissioningof dust, damp and vermin proof, outdoor type, wall mounted factory built sheet steel enclosed nondrawout modular panel for booster pump, fabricated out ofsuitable sized square tubular section andcoveredwith 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, dulypainted complete with earthbus, necessary metering protections & indications and mounted with the following including all inter connection etc.32A TP MCB with DOL starter, overload relay, start/stop push buttons, ammeter (0-40A) with three CT & selector switch, on/off/trip indication lights with protection fuse, single phase preventer. - 01 SetOne panel type volt meter 96mm square with Rotary selection switch for reading voltage between phase and neutral or incoming feeder. One Ampere meter 96mm square panel type of appropriate range Etched plastic identification plates for all switch gears. Space for 63 ampere MCB. All internal wiring should be colour coded from incoming main to switchgear, starters, meters, indicating lights. Single phasing preventors. (1 No.) Rotary manual/auto/off switch. (1 No.)
396Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
397150 mm dia
398100 mm dia
39980 mm dia
40065 mm dia
40150 mm dia
40240 mm dia
40332 mm dia
40425 mm dia
405Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780/14846 of following sizes as required : 150mm dia.
406Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 150mm dia.
407Providing, installation, testing and commissioning of cast iron body Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 150 mm nominal bore
408Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150mm dia.
409Providing and Fixing of gunmetal valve of following sizes as required.
41050mm nominal bore.
41125 mm nominal bore
412Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150 mm dia
413Supplying, installing, testing and commissioning flow switch (water flow detector) on sprinkler distribution header on each floor and shall be connected to fire alarm panel via monitor module for monitoring of water flow through cable.Suitable for 150 mm dia pipe
414Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1500 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required
415Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
416Providing and Fixing reinforced neoprene rubber vibration eliminators/expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 16 kg/cm2 pressure, as per specification of the manufacturers complete as required and as specified. 150mm dia.
417Providing and Fixing ISI marked portable type fire extinguishers of 6 Kg capacity ABC Dry Powder type as per IS- 15683complete as per specification and fixed / install as per site condition :
418Carbon-di- oxide type fire extinguisher 4.5 kg portable wall mounted type comprising of, CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket etc. complete, confirming to IS 15683. The cylinder must carry ISI mark.
419Providing and Fixing of 1 set G.I. sand buckets painted "Red Color" complete with G.I. stand duly painted "Red Color" of suitable size to hang a set of 4 nos Buckets at a time as per required specifications.
420Providing and fixing heavy duty copper armored cables 1.1 KVA grade including necessary support clamps at ceiling level and connection legs and double compression glands,complete in all respects. Control cable 2 core 1.5 Sq.mm
421Providing and fixing heavy duty Copper armored cables 1.1 KVA grade including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects. Power cable 3 core 6 Sq.mm
422Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
423Providing and fixing 25 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.
424Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 50mmx50mmx1.60mm trays
425Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
426Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
427Providing and Fixing of Internal Hose cabinet of size 750MMx 600MMx250MM made of 2mm thick MS sheet with 6mm thick glazed glass doors i/c necessary locking arrangement suitable to accomodate external hydrant with butterfly valve, two nos.15m long hose pipe, one no branch pipe, mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for Internal hydrant as required.
428Supplying & fixing 63 mm dia SS short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
429Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000 mm length
430Providing, installation testing and commissioning of adjustable rosset plate for 15mm dia in white finish UL listed or FM approved complete as required.
431Providing and Fixing 25mm dia. gunmetal air release valve PN 1.6 with all fittings and forged ball valve on header complete as required and as specified.
432Providing, fixing, testing and commissioning of 15 mm dia quartzoid bulb type sprinkler head for suitable K-Factor and Temperature rating as mentioned below and suitable for sustaining the pressure upto 12 Bar on the seat & water hammer effect. (UL/FM listed/approved)
433StandardResponse Pendant type sprinkler (K-80, Temp. Rating - 68oC
434StandardResponseUpright type sprinkler (K-80, Temp. Rating - 68oC)
435Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 b) 20 mm nominal internal dia gun metal globe valve & nozzle. c) Drum and brackets for fixing the equipmets on wall. d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
436Providing and Fixing of standard fireman"s axe as per IS:926 with heavy dutyinsulated rubber handle.
437Part-5 HVAC VRFSystem :
438Supply of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling & heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5The ODU shall have lownoisecondenserfans with extrenal static pressure of the outdoor unit shall be more then75Patoavoidhotairrecirculation,auto addresssetting,autocheckfunctionfor connection error and complete with indoor and outdoor unitswith individual controller and withfittingsetc.The compressor and VRV/VRF Outdoor make should be same. The unit shall also have feature to automaticallymodulatetheevaporative temperature between 6 deg C to 11 deg C with respecttoloadforbettercomfortandenergy efficiency, single module upto 20 HP only. The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units.
43920 HP
44022 HP
44124 HP
44226 HP
44328 HP
44460 HP
445HighwallSupply of Highwall unit with cordless remote.
4461.28 TR
4471.59 TR
4482.08 TR
4494 Way CasssetteSupply Cassette unit with cordless remote, 4 way supply air grill, DX copper coil, condensate water lift pump evaporator coil, fan section with low noise fan, multispeed motor, outer cabinet, drain pan andhanging arrangement with all accesseroies as required. All Indoor units must have force shut to connect with fire alarm to automatically stop in case of fire.
4503.02 TR
4512.56 TR
4521.65 TR
453Supply, Installation, Testing andCommissioningofY-joints and T joints of required sizes for SUB & connections of refrigerant pipes to units.
454Air Handling Units Supply of factory built Eurovent Certified (EN 1886:2007) Air handling units in Double skin type (Casing shall be of Non-Skeleton construction)with 40 mm thick panels consisting of G.I casing of thickness 0.6 mm outside layer and 0.6 mm inside layer with 275 GSM zinc coating and polyurethene foam(PUF) insulation having density of 42 kg/m3,complete with Backward curved aerofoil blade belt driven fan, Dx type cooling coil with aluminium finned copper tubes with face velocity 500 FPM. IE3 motor suitable for 415 +10% volts,50 Hz, 3 phase AC supply,drain connections with stainless steel drain pan and necessary vibration isolation arrangement to avoid any vibration etc. complete as per specifications and drawings.It shall include AHU Kit having Electronic Expansion valve & control kit to communicate capacity according to VRV/VRF ODU unit. 9600 CFM with 15 Sqft Coil Area, 6 RD Cooling Coil at 20 mm External Static Pressure.
455Supply of Wired remote for AHU"s.
456Central remote Controller (Touch Screen Type) : Supply of the I Touch-Manager + adaptor to control 340 indoor units complete with all necessary wire, support etc as per required. It must act as an advanced air conditioning management system to facilitate complete control of VRV/VRF air conditioning equipment, It should be user friendly through its touch screen, icon display and color LCD display. Integratable upto 64 remote controller groups(includingAHUs and BMS compatible with ethernet/Wi-Fi communication protocol for remote monitoring. In addition to basic controls such as settings for on/stop,the operation mode & temperature, the air quantity and auto louvercan be set. If a problem occurs, an alarm code immediately shows the detailsof the problem.An external input terminal is provided as standard. External signals enable the following function: central operation/stop, demand control, emergency stop,central operation output & central alarm output.
457Supply of power calculation software for each room.
458Supply of IS approved electrical energy meter with digital data logger complete with required smart features and accessries etc. for integration with I-Touch Manager
459Instalaltion, testing & commissioning, lifting and shifting and extra gas refrigerant charge of Modular type outdoor unitsequipped with highly efficient scrollcompressorswith all inverter type compressor (s) , specialheat exchanger,lownoise condenser fan , auto checkfunction for connection error, auto address setting & capacity as mentioned below.
46020 HP
46122 HP
46224 HP
46326 HP
46428 HP
46546 HP
46660 HP
467Installation of indoor units. Highwall
4681.28 TR
4691.59 TR
4702.08 TR
4714 Way Casssette
4723.02 TR
4732.56 TR
4741.65 TR
475Installation, Testing and commissioning of factory built Eurovent Certified (EN 1886:2007) Air handling units in Double skin type. 9600 CFM with 15 Sqft Coil Area, 6 RD Cooling Coil at 20 mm External Static Pressure (to be connected with 1 nos. VRV ODU of 28HP)
476Refrigerant Copper Piping Supply, Installation and Testing of copper refrigerant pipe (both suction & discharge pipe) work duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units all complete as per equipment specifications, drawings and direction of Engineer In charge. All piping inside the room shall be properly supported with hanger & pipe which are directly to the sun shall run in covered powder coated perforated cable tray as per approved drawing of supporting/ handing arrangment. (cable tray shall be paid separately under relevant item).
47741.3 mm dia / 19 mm thick insulation
47838.1 mm dia / 19 mm thick insulation
47934.9 mm dia / 19 mm thick insulation
48031.8 mm dia / 19 mm thickinsulation
48128.6 mm dia / 19 mm thickinsulation
48225.4 mm dia / 19 mm thick insulation
48322.2 mm dia / 19 mm thick insulation
48419.1 mm dia / 13 mm thick insulation
48515.9 mm dia / 13 mm thick insulation
48612.7 mm dia / 13 mm thick insulation
4879.5 mm dia / 13 mm thick insulation
4886.4 mm dia / 13 mm thick insulation
489Drain Piping Providing and fixing rigid PVC Drain piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation/ polyethlene sheet for condensate from room unit to nearest suitable drain system as per site conditions as per instructed at site engineer complete with all required fittings and providing clean out plug at suitable location for roding the pipe when required complete.
49050 mm dia
49132 mm dia
49225mm dia
493AIR DISTRIBUTION Supply, installation, balancing and commissioning of factory fabricated Galvanized Steel Sheets (GSS) rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitters, dampers, vanes, hangers, supports/ suspenders bends, tees, vanes, double canvas connection of the equipment etc. as per approved drawings and specifications of following sheet thickness complete as required.
4941.00 mm thick (20 Gauge)
4950.80 mm thick (22 Gauge)
4960.63 mm thick (24 Gauge)
497Supply, installation, balancing and commissioning of site fabricated Galvanized Steel Sheets (GSS) rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitters, dampers, vanes, hangers, supports/ suspenders bends, tees, vanes, double canvas connection of the equipment etc. as per approved drawings and specifications of following sheet thickness complete as required.
4981.00 mm thick (20 Gauge)
4990.80 mm thick (22 Gauge)
500Duct Insulation Supply and fixing of following thickness of 13mm closed cell nitrile rubber Class O fire rated insulation on existing duct after applying suitable adhesive recommeded by manufacturer of insulation for nitrile rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specification and as required.
501Supplying and fixing 10mm of acoustic lining within the supply air duct with open cell nitrile rubber ( 180-220 Kg/cum density) with UL approvedas per specifications and drawings.
502Supply, Installation and Testing of return air grilles/ diffusers wit louvers but without volume control dampers as per specifications and drawings.
503Supply, Installation and Testing of supply air grilles/ diffuserswith alluminium volume control as per specifications and drawings with anti smudge ring and removable core.
504Providing and fixing of 125mm wide flexible connections at the Inlet/Outlet of AHUs/Extract Fan Section/Outlet of FCUs. The rubber material shall be all weather proff fire retardent fabroc as per specifictaions shall be provided with GSS frame with Gasket, Nuts & Bolts.
505Installation, testing and commissioning of I-touch Controller and adaptor remote controller unit.
506Installation of smart meter.
507CIVIL WORK Chase cutting in walls, holes for drain piping and ducting in walls.
508STANDS Supply and installation of MS Stands for each outdoor unit with viberation pads as approved by Engineer in charge.
509Supply and Installation of following size of GI perforated cable tray including horizontal and vertical bends, reducers, tees, cross members & other accesries as required & duly suspended from the ceiling with c channel suspenders as required.
510300 mm (w) x 50 mm (d) x 1.6 mm (t) with cover
511450 mm (w) x 50 mm (d) x 1.6 mm (t) with cover
512Supply, Installation and Testing of Metal body Propeller fans with bird screen, frame etc. complete with all accessories. Suitable to operate at 220V 1 Ph 50 Hz power supply.
513300mm dia- for toilet exhaust
514450mm dia- for toilet exhaust
515600mm dia- for kitchen exhaust
516Part-6 Electrical work for HVAC Works
517Providing, fixing, testing and commissioningof vermin proof, dust proof Outdoor type, floor mounted factory built sheet steel enclosed nondrawout modular panel for booster pump, fabricated out ofsuitable sized square tubular section andcoveredwith 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, dulypainted complete with earthbus, necessary metering protections & indications and mounted with the following including all inter connection etc.VRV Sub-Main Distribution Board :IP65 (For Outdoor Application) : is as specified below :- Note:- 1. Relay setting & co-ordination with up & down stream breaker shall included with this line item. INCOMER: 1 no. 630A C-Curve, 25kA, 4P MCCB. 1 Set ofON,OFF LED indicating lamp with MCB protection. BUSBARS: 800 Amp 4P (10kA for 1sec) aluminium busbar chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips. Current density of aluminiumshall not be more than 0.8 Amps/ sq.mm. OUTGOINGS: 13 No. 63A, TPN MCB 17 Nos. 40A, TPN MCB 1 No. 32A, SP MCB
518VRV Sub-Main Distribution Board :IP65 (For Outdoor Application) : is as specified below :- Note:- 1. Relay setting & co-ordination with up & down stream breaker shall included with this line item. INCOMER: 1 no. 630A C-Curve, 25kA, 4P MCCB. 1 Set ofON,OFF LED indicating lamp with MCB protection. BUSBARS: 800 Amp 4P (10kA for 1sec) aluminium busbar chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips. Current density of aluminiumshall not be more than 0.8 Amps/ sq.mm. OUTGOINGS: 15 No. 63A, TPN MCB 19 Nos. 40A, TPN MCB 1 No. 32A, SP MCB
519Providing, fixing, testing and commissioning of Indoor type, floor mounted factory built sheet steel enclosed nondrawout modular panel for booster pump, fabricated out ofsuitable sized square tubular section andcoveredwith 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, dulypainted complete with earthbus, necessary metering protections & indications and mounted with the following including all inter connection etc.HVAC Sub-Main Distribution Board for Auditorium is as specified below :- Note:- 1. Relay setting & co-ordination with up & down stream breaker shall included with this line item. INCOMER: 1 no. 125A C-Curve, 25kA, 4P MCCB. 1 Set ofON,OFF LED indicating lamp with MCB protection. BUSBARS: 160 Amp 4P (10kA for 1sec) aluminium busbar chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips. Current density of aluminiumshall not be more than 0.8 Amps/ sq.mm. OUTGOINGS: 8 No. 25A, TPN MCB DOL Starter 1 Nos. 32A, TPN MCB Star Delta Starter 1 No. 32A, SP MCB Starters shall have following provisions and features: MCB with DOL starter, overload relay, start/stop push buttons, ammeter (0-40A) with three CT & selector switch, on/off/trip indication lights with protection fuse, single phase preventer. - 01 Set One panel type volt meter 96mm square with Rotary selection switch for reading voltage between phase and neutral or incoming feeder. One Ampere meter 96mm square panel type of appropriate range. Etched plastic identification plates for all switch gears. All internal wiring should be colour coded from incoming main to switchgear, starters, meters, indicating lights. Single phasing preventors. (1 No.) Rotary manual/auto/off switch. (1 No.)
520Providing, fixing, testing and commissioning of Indoor type, floor mounted factory built sheet steel enclosed nondrawout modular panel for booster pump, fabricated out ofsuitable sized square tubular section andcoveredwith 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, dulypainted complete with earthbus, necessary metering protections & indications and mounted with the following including all inter connection etc.Emergency Ventilation Sub-Main Distribution Board for Auditorium is as specified below :- Note:- 1. Relay setting & co-ordination with up & down stream breaker shall included with this line item. INCOMER: 1 no. 125A C-Curve, 25kA, 4P MCCB. 1 Set ofON,OFF LED indicating lamp with MCB protection. BUSBARS: 125 Amp 4P (10kA for 1sec) aluminium busbar chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips. Current density of aluminiumshall not be more than 0.8 Amps/ sq.mm. OUTGOINGS: 8 No. 25A, TPN MCB 1 No. 32A, SP MCB
521CABLE, TERMINATION AND FLEXIBLE WIRE.Supply And Laying XLPE PVC armoured cable of 1100 V grade of Aluminium/ Copper conductor with brass termination of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. Termination set shall be as per above I/Gs and O/Gs mentioned
522300 sq.mm x 3.5 c Al cable (MDB to VRV Panel)
523120 sq.mm x 4 c Al cable (MDB to VRV Panel)
52410 sq.mm x 4 c Cu. cable ( SMDB to HVAC VRF ODU)
5254 sq.mm x 3 c Cu. cable
5264 sq.mm x 4 c Cu. cable
5271.5 sq.mm x 3 c Cu. cable
528SITC of IP65 isolator box with RCBO
52963 A
53040 A
53125A/32A 3P Isolator for AHU Motor
532CABLE TRAY Supply and installation ofPerforated G.I cable tray of thickness 2mm/1.6mm and galvanization thickness of 120 Mic. The cable tray shall be supplied with all necessary hardwares, couplers. The bends and cross shall be of pre fabricated type and the same will be measured in the straight length.
533450 x 50 made out of 2 mm thick
534300 x 50 made out of 1.6 mm thick
535100 x 50 made out of 1.6 mm thick
536Supply and laying earthing strips for interconnecting the earthing stations, panels, DB"s etc. in built-up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with : b) Corrosion protection of buried conductors with bitumino us coating and covered with PVC tapes. c) All strip used for earthing should be provided with green color PVC sleeves.
53725 x 3 mm GI. Strip with 1.1KV insulation sleeve
53825 x 6 mm GI. Strip with 1.1KV insulation sleeve
539Part 7 SMOKE EXTRACTION SYSTEM
540Supplying, installing, testing and commissioning of Smoke extraction Axial fans as per specifications. Fan shall be with direct driven Tube axial fan. The fan shall be equipped with mounting bracket, fire rated flexible connection. Cost of spring isolators for the installation of the fans needs to be included.The motor shall be Class H rating and suitable for 415±10% volts 3 phase 50 cycles, AC supply. The motor selected shall be IE2 efficiency at full load. Fan shall be selected for minimum efficiency of 60-70%. Fan will be selected on the basis of best in-class efficiency. Fan and casing shall be suitable for normal & smoke exhaust application.Motor shall be mounted inside the fan casing & thermally rated for 250 Deg Cfor 2 hour as per [BS-7346 Part-2 : 1090].Fan used in case of fire can be selected for higher outlet velocity as sound is not criteria while selecting. Bird screen, mounting bracket, fastners shall be souced from fan OEM. Supply and Installation of spring hangers for all above mention Fans. The hangers should consist of a free-standing, laterally stable steel spring and elastomeric washer in series, assembled in a stamped or welded steel bracket with a Neoprene element at the top . The hanger bracket shall be designed to carry five times overload without failure and shall allow up to 30 degree rod misalignment without metal to metal contact. The spring should have a minimum deflection of 25 mm and Neoprene element minimum 4mm deflection.
541Supply, installation, testing & commissioning of Axial Flow Fans suitable for installing in both Horizontal or vertical position as per site requirement and complete with totally encloseddirect driven, motor mount, fire rated flexible connection and vibration isolators. The fan shall be equipped with mounting bracket.The motor shall be suitable for 415±10% volts 3 phase 50 cycles, AC supply. The motor selected shall be IE 2 efficiency . Supply and Installation of spring hangers for all above mention Fans. The hangers should consist of a free-standing, laterally stable steel spring and elastomeric washer in series, assembled in a stamped or welded steel bracket with a Neoprene element at the top . The hanger bracket shall be designed to carry five times overload without failure and shall allow up to 30 degree rod misalignment without metal to metal contact. The spring should have a minimum deflection of 25 mm and Neoprene element minimum 4mm deflection.
542Supply, installation, testing and commissioning of Motorised Combined Smoke & Fire Damper (UL rated). The quoted price shall include control panel alongwith fire resistant inter connecting wiring and also termination of Fire alarm control wiring.
543Smoke & Fire Dampers.
544Control Panel & Wiring (including actuators)
545Supplying & fixing of opposed blade GI construction Volume Control DampersinRectangular supplyairductas per approved drawings and specifications.
546Supply, installation and balancing of Extruded Aluminium construction Supply Air Grilles with Volume Control Dampers. The grilles will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications.The grilles may be double or single louvered, adjustable or fixed as required by Client
547Supply, installation and balancing of Extruded Aluminium construction Exhaust Air Grilles without Volume Control Dampers. The grilles will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications. The grilles may be double or single louvered, adjustable or fixed as required by Client
548Supply, installation, testing and balancing of Powder coated/Anodisedextruded aluminium construction inlet air louvers with bird screen for fresh air alongwith GI construction volume control damper.The louvers will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications.
549Supply, installation, testing and balancing of Powder coated/Anodisedextruded aluminium construction exhaust air louvers with bird screen.The louvers will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications.
550Providing, fixing, testing and commissioningof Indoor type, wall mounted factory built sheet steel enclosed nondrawout modular panel for booster pump, fabricated out ofsuitable sized square tubular section andcoveredwith 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, dulypainted complete with earthbus, necessary metering protections & indications and mounted with the following including all inter connection etc. 25A TP MCB with DOL starter, overload relay, start/stop push buttons, ammeter (0-40A) with three CT & selector switch, on/off/trip indication lights with protection fuse, single phase preventer. - 01 SetOne panel type volt meter 96mm square with Rotary selection switch for reading voltage between phase and neutral or incoming feeder. One Ampere meter 96mm square panel type of appropriate range. Etched plastic identification plates for all switch gears. All internal wiring should be colour coded from incoming main to switchgear, starters, meters, indicating lights. Single phasing preventors. (1 No.) Rotary manual/auto/off switch. (1 No.)
551Providing and fixing heavy duty Copper armored cables 1.1 KVA grade including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects. Power cable 3 core 4 Sq.mm
552Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 50mmx50mmx1.60mm trays
553Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail