| 1 | Earth work in excavation by mechanical means (HydraulicExcavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil asdirected, within a lead of 50 m.in all kinds of soil. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinthsides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m. |
| 3 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8(1Cement:4coarsesand:8gradedstoneaggregate 40 mm nominal size). |
| 4 | Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 5 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level withCement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand |
| 7 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete1:1.5:3(1cement:1.5coarse sand: 3gradedstoneaggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in walls (any thickness), includingReinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size) |
| 10 | Centring and shuttering including strutting,ropping etc. and removal of form forCentring and shuttering for foundations, footings, bases of columns, etc. for mass concrete. |
| 11 | Centring and shuttering including strutting,ropping etc. andremoval of form for Suspendedfloors,roofs,landings,balconiesandaccess platform. |
| 12 | Centring and shuttering including strutting,ropping etc. andremoval of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Centring and shuttering including strutting,ropping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.Hot rolled deformed bars |
| 15 | Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together bymechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge.Profile B |
| 16 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.Ingratings,frames,guardbar,ladder,railings,brackets,gates and similar works. |
| 17 | ProvidingandfixingM.S.Tubularframesfordoors,windows, ventilatorsand nuts asrequired including fixingofnecessarybutthinges andscrews and applyinFixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 18 | 12 mm cement plaster of mix1:6 (1 cement : 6 fine sand |
| 19 | 15 mm cement plaster on rough side of single or half brick wall of mix1: 6 (1 cement: 6 fine sand) |
| 20 | Cement plasterskirting(upto30 cm height) with cement mortar1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 18 mm thick |
| 21 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thickcement mortar 1:3 (1 Cement : 3 fine sand). |
| 22 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 23 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 24 | Providingandfixingglassstripsinjointsofterrazo/cementconcrete floors. 40 mm wide and 4 mm thick. |
| 25 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)non decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 26 | Providing and fixing ISI marked oxidised M.S.sliding door bolts250x16mm |
| 27 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 200x10 mm |
| 28 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS125 mm |
| 29 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete.With 4.0 mm thick glass panes. |
| 30 | Providing&laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting ofapplying:(a) after surface prepration, first layer of slurry of cement@ o.488kg/sqm mixed with waterproofing compound &.0.253kg/sqm (b) laying second layer of fiber glass cloth when the first layer is still green. overlaps of joints of fiber glass cloth should not be less than 10 cm.(c)third layer of 1.5mm thickness consisting of slurru of [email protected]/sqm mixed with waterproofing [email protected]/sqm and course [email protected]/sqm thish will be allowed to air cure for 4 huors followed by wter curring for 48 hours. the entire treatment will be taken up to 30cm on parapit wall and tucked into groove in parapit all around(d) fourth &final layer of brick tiling with cement morter (which will be paid seprately .for purposeof measurement the entire treated surface will be measured. |
| 31 | 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 |
| 32 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 33 | Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). |
| 34 | Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete, as per manufacturer’s specificationTwo or more coats on new work. |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 36 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including finishing the topsmooth. |
| 37 | Providingandfixinginpositioncollapsiblesteelshutterswithverticalchannels 20x10x2mm and braced with flat iron diagonals 20x5mm sizewithtopandbottomrailofT-iron40x40x6mmwith40mmdia,steelpulleyscompletewithbolts,nuts,lockingarrangement,stoppers,handles, including applying a priming coat of approved steel primer. |
| 38 | Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 |
| 39 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction |
| 40 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
| 41 | Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
| 42 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix (1:2:4) |