Tender For Hvac Work At Regional Food And Drug Lab And Regional Office Distt-Gonda, gonda-Uttar Pradesh

Uttar Pradesh Projects Corporation Limited has published Tender For Hvac Work At Regional Food And Drug Lab And Regional Office Distt-Gonda. Submission Date for this Tender is 15-01-2024. HVAC Tenders in gonda Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41512858
Tender For Hvac Work At Regional Food And Drug Lab And Regional Office Distt-Gonda
Open Tender
Indian
Uttar Pradesh
gonda
15-01-2024

Tender Details

Tender For Hvac Work At Regional Food And Drug Lab And Regional Office Distt-Gonda

Key Value

Document Fees
INR 11800 /-
EMD
INR 192000.0 /-
Tender Value
INR 95.80 Lakhs /-

BOQ Items

Name of Work: HVAC WORK AT REGIONAL FOOD & DRUG LAB AND REGIONAL OFFICE DISTT-GONDA
Sl. No. Item Description
1Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.
2Providing & laying cement concrete in 1:4:8 (1 cement: 4 coarse sand: 8 graded brick aggreagate 40mm nominal size) including supply of all materials,labour and T & P etc. required for completion of work and curing complete including cost of form work in foundation and floors
3Class-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
4Class-150 brick workin 1:4 cement & coarse sandcement of 1.50 fineness modulus mortar insuper-structure including necessarycutting andmouldingofbricksrequiredandalsoincludinghoney comb brick workthickness of wall more than one brick and for extra labour to above items Ground Floor
512mm Cement plaster with cement mortar in proportion of 1:6 cement & coarse sand of single coat for interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm in girth and finished even and smooth. Ground Floor
6Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor).
7OUTDOOR UNIT"S Supply, installation, Testing and comissioning of Modular type outdoor units, with all BLDC scroll Inverter compressor for cooling and heating application. The unit must runs with two no"s of inverter compressors above 16HP along with the same shall having minimum COP of 3.7 at standard condition at 100% load. All inverter capacity controlling compressor is suitable for 380~415 volts, 3 Phase, 50 Hz. Condenser Fins should have factory anticorrosive coating treatment and same treatment should have third party certification from UL/TUV under the standard Salt Spray test method of ISO21207. All ODU unit compressors should have inbuilt oil level sensor so as to ensure reliable oil return technology to further add additional safety for Compressor. The manufacturer must be an OEM of its compressors and should be having manufacturing and NABL certified testing facility in India. The Outdoor PCB should be having the technology to be cooled by refrigerant. Outdoor unit must not having any de-ration up to 39 deg ambient and should have wide operation range from -5? C to 53? C. The outdoor unit must have the feature of Record running parameters of last 3 minutes before failure, for fault analysis & easy and faster trouble 12 HP ( Heating & Cooling)
822 HP ( Heating & Cooling)
9INDOOR UNIT"S Supply, of Indoor units equipped with pre-filter, fan section with suitable static fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities as per specifications. MAKE:- LG 4 WAY CASSETTES UNIT.-1.5 Tr Cassette 4 Way
102.0 Tr Cassette 4 Way (840 x 840)
112.5 Tr Cassette 4 Way (840 x 840)
123.0 Tr Cassette 4 Way (840 x 840)
133.5 Tr Cassette 4 Way (840 x 840)
144.5 Tr Cassette 4 Way (840 x 840)
15HIGH WALL UNIT. 1.25 High Wall (Wall mounted)
161.65 High Wall (Wall mounted)
172.0High Wall (Wall mounted)
18ACCESSORIES.- 4 Way Cassette Panel G-Style (840 x 840)
19Y Branch IDU
20Y Branch ODU
21Wired/Wireless Remote
22Basic Total Amount Equipment GROUP "B" (Low Side Works)- ITC FOR OUTDOOR UNIT 22 HP ( Heating & Cooling)
2312 HP ( Heating & Cooling)
24ITC FOR INDOOR UNIT"S- 4 WAY CASSETTES UNIT- 1.5 Tr Cassette 4 Way (840 x 840)
252.0 Tr Cassette 4 Way (840 x 840)
262.5 Tr Cassette 4 Way (840 x 840)
273.0 Tr Cassette 4 Way (840 x 840)
283.5 Tr Cassette 4 Way (840 x 840)
294.5 Tr Cassette 4 Way (840 x 840)
30HIGH WALL UNIT- 1.25 High Wall (Wall mounted)
311.65 High Wall (Wall mounted)
322.0High Wall (Wall mounted)
33Refrigerant Piping for VRV / VRF System- Supply, installation, testing and commissioning of interconnecting 53.9 mm OD ( insulation 19mm) 16 Gauge, 44.4 mm OD ( insulation 19mm) 16 Gauge, 41.3 mm OD ( insulation 19mm) 16 Gauge, 34.9 mm OD ( insulation 19mm) 16 Gauge, 28.58 mm OD ( insulation 19mm) 16 Gauge, 25.0 mm OD ( insulation 19mm) 16 Gauge, 22.2 mm OD ( insulation 19mm) 16 Gauge, 19.05 mm OD ( insulation 19mm) 16 Gauge, 15.88 mm OD ( insulation 19mm) 20 Gauge, 12.7 mm OD ( insulation 19mm) 20 Gauge, 9.52 mm OD ( insulation 13mm) 20 Gauge, 6.35 mm OD ( insulation 13mm) 20 Gauge
34Condensate Drain Piping 25 mm dia pipe, Insulation Thick - 6 mm
3532 mm dia pipe, Insulation Thickness - 6 mm
36TRANSMISSION WIRING. Supplying and drawing following sizes of PVC insulated Copper
37Miscelaneous Work Lifting & Shifting of Units
38Outdoor Stands Fabrication of M.S chanel stand for outdoor units
39Refregrent Add Refregrent Charging (R410 A)
40Y Branch IDU Installation of y branch in indoor unit
41G.I.Cable Tray Supply & Installation of Cable tray
42GST Extra as per avlivel
Disclaimer :