Tender For Routine Maintenance Of Fire Alarm System, Smoke Detection, Fire Fighting System And Other Fire Fighting Assets And Connected Items Under Age E/M -Ii In Ge (U) Chandimandir., chandimandir-Haryana

Military Engineer Services-MES has published Tender For Routine Maintenance Of Fire Alarm System, Smoke Detection, Fire Fighting System And Other Fire Fighting Assets And Connected Items Under Age E/M -Ii In Ge (U) Chandimandir.. Submission Date for this Tender is 03-02-2024. Alarm Systems Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

41483856
Tender For Routine Maintenance Of Fire Alarm System, Smoke Detection, Fire Fighting System And Other Fire Fighting Assets And Connected Items Under Age E/M -Ii In Ge (U) Chandimandir.
Open Tender
Indian
Haryana
chandimandir
03-02-2024

Tender Details

Tender For Routine Maintenance Of Fire Alarm System, Smoke Detection, Fire Fighting System And Other Fire Fighting Assets And Connected Items Under Age E/M -Ii In Ge (U) Chandimandir.

Key Value

Document Fees
INR 1000 /-
EMD
INR 130000.0 /-
Tender Value
INR 70 Lakhs /-

BOQ Items

Name of Work: ROUTINE MAINT OF FIRE ALARM SYSTEM, SMOKE DETECTION, FIRE FIGHTING SYSTEM AND OTHER FIRE FIGHTING ASSETS AND CONNECTED ITEMS UNDER AGE E/M -II IN GE (U) CHANDIMANDIR
Sl. No. Item Description
1Servicing/Maintenance of fire alarm system Make:- Morley installed at War Gaming Centre complete all as specified and directed comprising following services/maintinance to be carried out under this item:- (i) Small spare parts as required (like wire, lugs, pvc caps, nuts and bolts etc.) shall be measured under this item. (ii) The work shall be executed by OEM or his authorised agency only as approved by GE. (iii) Checking of Alarm, signal should not lost when primery power failure untill the alarm signal processed. (iv) Checking of audio amplifiers and tone genrating equipment (v)Checking of smoke detector sensibility. (vi) checking of all speaker circuit and loops. Note:- Work carried in restricted area and the contractor getprior permision of DEPARTEMENT for work. .
2Servicing/Maintenance of fire alarm system Make: Morley installed at COMPAD Building (Chanakya Bldg) complete all as specified and as directed comprising following services/maintinance to be carried out under this item:- (i) Small spare parts as required (like wire,lugs,pvc caps,nuts and bolts etc.) shall be measured under this item. (ii)The work shall be executed by OEM or his authorised agency only as approved by GE. (iii) Checking of Alarm, signal should not lost when primery power failure untill the alarm signal processed. (iv)Checking of audio amplifiers and tone genrating equipment. (v)Checking of smoke detector sensibility. (vi)Checking of all speaker circuit and loops.
3Servicing/Maintenance ofof fire alarm system( two nos of Pannel) Make: Morley installed at HQ Western Command Building complete all as specified and directed comprising following services/maintinance to be carried out under this item:- (i)Small spare parts as required (like wire,lugs,pvc caps,nuts and bolts etc.) shall be measured under this item. (ii)The work shall be executed by OEM or his authorised agency only as approved by GE. (iii) Checking of Alarm, signal should not lost when primery power failure untill the alarm signal processed. (iv)Checking of audio amplifiers and tone genrating equipment. (v)Checking of smoke detector sensibility. (vi)Checking of all speaker circuit and loops.
4Servicing/Maintenance of fire alarm system Make: Morley installed at Manekshaw auditorium complete all as specified anddirected comprising following services/maintinance to be carried out under this item:- (i)Small spare parts as required (like wire,lugs,pvc caps,nuts and bolts etc.) shall be measured under this item. (ii) The work shall be executed by OEM or his authorised agency only as approved by GE. (iii) Checking of Alarm, signal should not lost when primery power failure untill the alarm signal processed. (iv)Checking of audio amplifiers and tone genrating equipment (v)Checking of smoke detector sensibility. (vi)Checking of all speaker circuit and loops.
5Servicing/Maintenance of fire alarm/ Sprinkler system Make: Honeywell installed atCar parking at HQWC complete all as specified anddirected comprising following services/maintinance to be carried out under this item:- (i)Small spare parts as required (like wire,lugs,pvc caps,nuts and bolts etc.) shall be measured under this item. (ii) The work shall be executed by OEM or his authorised agency only as approved by GE. (iii) Checking of Alarm, signal should not lost when primery power failure untill the alarm signal processed. (iv)Checking of audio amplifiers and tone genrating equipment (v)Checking of smoke detector/Sprinkle sensibility. (vi)Checking of all speaker circuit and loops.
6Supply, Installation, Testing and Commissioning in replacement of analog addressable type self acclaimatising multi sensing Photo and heat detector with standard mounting base, LED, Address switch completefor mounting on surface /on false ceilling/ below false floor, cable Lugs at ends, cable compression glands, cable tags and ferruling complete all as specified and directed. Make:-Morley/ Honeywell/ Notifier.
7Supply, Installation, Testing and Commissioning in replacement of UL listed analog addressable dual action manual pull station/ glass break with address switch and all mounting accessories complete for mounting on surface /on false ceilling/ below false floor, cable iugs at ends, cable compression glands, cable tags and ferruling complete all as specified and directed.
8Supply, Installation, Testing and Commissioning in replacement of addressable control input module with address switch and all mounting accessories complete for mounting on surface, cable lugs at ends, cable compression glands, cable tags and ferruling complete all as specified and directed.
9Supply, Installation, Testing and Commissioning in replacement of addressable control output module with address switch and all mounting accessories,comlete for mounting on surface,cable lugs at ends,cable compression glands,cable tags and ferruling complete all as specified and directed. Make:-Morley/Honeywell/Notifier.
10Supply, Installation, Testing and Commissioning in replacement of fault isolator module,complete with for mounting on surface, cable lugs at ends,cable compression glands, cable tags and ferruling complete all as specified and directed. Make :- Morley/ Honeywell/ Notifier.
11Supply & Fixing in replacement of hooter with all required accessories for mounting complete all as specified and directed.
12Supply & Fixing in replacementresponse indicator withmatching screws complete with GI junction box etc all as specfied and direected.
13Supply, Installation, Testing and Commissioning in replacementof UL listed with qwerty keypad networkable repeater panel having 640 character backlit LCD displays function keys and soft keys, Repeater panel should be on true peer to peer network complete all as specified and directed.
14Supply and fixing in replacementof hose pipe reelwith capacity of minimum working pressure of 20 bar complete all as specified and directed.
15Supply, Installation, Testing and Commissioning in replacement2 Loop Control Panel 230Vac 4 sounder circuits , 4 line display and networking capability , 6 Amp PSU with 460 Ma loop capability 500*500*195 mm (H8W8D) including Mother Board with power Supply copletely all as directed.
16Supply, Installation, Testing and Commissioning in replacementSingle Loop Control Panel 230Vac 4 sounder circuits , 4 line display and networking capability , 6 Amp PSU with 460 Ma loop capability 500*500*195 mm (H8W8D) including Mother Board with power Supply copletely all as directed.
17Supply, Installation, Testing and Commissioning in replacement4 Loop Control Panel 230Vac 4 sounder circuits , 4 line display and networking capability , 6 Amp PSU with 460 Ma loop capability 500*500*195 mm (H8W8D) including Mother Board with power Supply copletely all as directed.
18Supply, Installation, Testing and Commissioning in replacementLoop Driver Card suitable for 4 line disply complete all as specified and directed.
19Supply, Installation, Testing and Commissioning in replacementRS 485 Communication Card and as directed.
20Supply, Installation, Testing and Commissioning in replacement Loop control module suitable for 4 line display complete all as specified and directed.
21Supply , fixing & Testingin replacement ofZHFR cable of size 1.5 Sqmm,2 core Sheathedincluding passing through exisiting conduit / exisiting route and necessary cutting and chessing of wall / roof for laying of cable and neceesary PCC work for cutting surface complete all as specified and directed.
22Supply and fixing in replacement of battery 12V 7AH complete all specifed.
23Supply and fixing in replacementintelligent and addressable FSB-200 Seriessmoke sensing technology Beam indicatorwith reflector complete set, FSB-200 Single-ended beam smoke detector Operating Temperature: –22°F to 131°F (–30°C to 55°C), FSB-200S Single-ended beam smoke detector with integral sensitivity test, Operating Temperature: –22°F to 131°F (–30°C to 55°C), 16 to 328 foot protection range , Single-ended, reflected type design, Paintable cover complete all as specified and as directed.
24Supply and fixing in replacement MS pipe 150 mm diaincluding welding work complete all as specified.
25Supply and fixing in replacement MS pipe 100 mm diaincluding welding work complete all as specified.
26Supply and fixing in replacement MS pipe 80 mm diaincluding welding work complete all as specified.
27Supply and fixing in replacement MS pipe 50 mm diaincluding welding work complete all as specified.
28Supply and fixing in replacement MS pipe 32 mm diaincluding welding work complete all as specified.
29Supply and fixing in replacement MS pipe 25 mm diaincluding welding work complete all as specified.
30“Supply and fixing glow signage board such as ""FIRE EXIT"" , ""FIRE HYDRANT BOX"" etc. on the board with base frame made from angle iron and back side from ACP sheet 3 mm thick with IP 68 protecttion LED module, good quality virgin monomer acrylic sheet , 3 inch rising moulding of acrylic letter with 5 mm sun board channel, including complete wiring and SMPS power supply with IP 68 protection, Each letter will be made with computer offset for having same letter style and type as approved by Engineer-in-Charge , all as directed and specified.”
31Material and Labour for preparing old painted steel surfaces of over 10 cm in width or girth and applying one coat of synthetic enamel paint as per the colour standard specified by the Engineer-in-Charge.
32Supply and fixing in replacement PVC Canvas Fire Hose Pipe, Dia 65 MM , length 30mtr, with lining, Min pressure 0.8 Mpa, including 65 mm dia stainless steel mail femailcoupling complete all as specified and directed by Engineer-in-Charge.
33Supply and fixing in replacement PVC Canvas Fire Hose Pipe, Dia 65 MM , length 15 mtr, with lining, Min pressure 0.8 Mpa, including 65 mm dia stainless steel mail femailcoupling complete all as specified and directed by Engineer-in-Charge.
34Supply and fixing in replacement of Nozzle made of brass for connecting with hose reel for extinguishing fire of size 65 mm including nut and bolts complete all as specified and directed by Engineer-in-Charge.
35Material and Labour for drilling and welding for connection of 4 inch hydrant line to 0.5 inch using nipples and gate valves on both ends complete all as specified and directed by Engineer-in-Charge.
36Taking down carefully centrifugal pump set 60 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, inlet, delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on load for smooth operation , complete all as specified and as directed. Spare parts if any required to be replaced shall measured and paid under respective schedule of item here in- after as supply only. labour element for fixing of any defective part/spare shall be part of this item.
37Supply only pump shaft sleeve made of gun metal suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
38Supply only key for main shaft/impeller (SS 410) suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
39Supply only check nut suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
40Supply only stuffing box bush suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
41Supply only motor pump M S coupling with spacer LR 226 type complete with nut, bolts etc suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
42Supply only water seal suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
43Supply only stuffing box packing and greasing suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
44Supply only star couplingtype LR-226 suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
45Supply only bronze impeller suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
46Supply only pump set bearing housing DE/NDE of CI grade FG 210 suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed.
47Supply only ball bearing (roller/ thrust/ any other type) DE/NDE suitable for 60HP motor pump as per manufacturer"s design complete all as specified and as directed. Note:All the items/parts mentioned srl 37 to 47 here-in-before shall be suitable/ compatible for the type and make of pumping set as mentioned against each item and cost of fixing of items is deemed to be included in the quoted rate of item No. 36
48Taking down carefully jockey pump set 10 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, inlet, delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on load, complete all as specified and as directed.Spare parts if any required to be replaced shall measured and paid under respective schedule of item here-in-after item as supply only, labour eliment for fixing of any defective part/spare shall be part of this item. Make of pump:- KSB, Kirloskar, Mather platt or any Make existing on site.
49Supply only pump shaft sleeve made of gun metal suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.
50Supply only key for main shaft/impeller (SS 410) suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.
51Supply only check nut suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.
52Supply only stuffing box bush suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.
53Supply only motor pump M S coupling of suitable size complete with nut, bolts etc suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.
54Supply only water seal suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.
55Supply only stuffing box packing and greasing suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.
56Supply only tyre coupling of suitable size suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.
57Supply only cast iron impeller suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.
58Supply only ball bearing (roller/ thrust/ any other type) DE/NDE suitable for 10HP motor pump as per manufacturer"s design complete all as specified and as directed.Make - NBC, SKF,ABC Note:All the items/parts mentioned srl 49 to 58 here-in-before shall be suitable/ compatible for the type and make of pumping set as mentioned against each item and cost of fixing of items is deemed to be included in the quoted rate of item No.48
59Taking down defective electric motor, squirrel cage type of any make, from base plate after unscrewing nuts, bolts of foundation/ coupling (approx weight 600kg), 3 phase, 415/440 volts, 50 c/s, AC, capacity 60 HP,shifting the same to workshop, strip opening after unscrewing nuts, bolts/ screws etc. taking out rotor from stator, cutting and taking out burnt winding carefully from the stator, cleaning of slots, rewinding of stator with super enameled copper winding wire of appropriate size matching with manufacturer"s design including replacement of all insulating materials such as glass paper, leathered paper, PVC insulated copper conductor wire connection leads of appropriate size with sleeves of suitable size upto terminal connection box, varnishing, drying up and re-assembling, re-fxing and re-installationat site and testing on load all as specified and directed by Engineer-in-Charge. Note:- Required T&P such as chain pulley block and tranportation shall be contractors responsibility. Repair/ replacement of shall be done within a period as intimated by the Engr-in-Charge falling which necessary recoveryshall be made. (iii) Repair shall be done from any workshop within a radius of 5KM from GE(U) Chm.
60Taking down defective electric motor, squirrel cage type of any make, from base plate after unscrewing nuts, bolts of foundation/ coupling (approx weight 600kg), 3 phase, 415/440 volts, 50 c/s, AC, capacity 10 HP,shifting the same to workshop, strip opening after unscrewing nuts, bolts/ screws etc. taking out rotor from stator, cutting and taking out burnt winding carefully from the stator, cleaning of slots, rewinding of stator with super enameled copper winding wire of appropriate size matching with manufacturer"s design including replacement of all insulating materials such as glass paper, leathered paper, PVC insulated copper conductor wire connection leads of appropriate size with sleeves of suitable size upto terminal connection box, varnishing, drying up and re-assembling, re-fxing and re-installationat site and testing on load all as specified and directed by Engineer-in-Charge. Note:- Required T&P such as chain pulley block and tranportation shall be contractors responsibility. Repair/ replacement of shall be done within a period as intimated by the Engr-in-Charge falling which necessary recoveryshall be made. (iii) Repair shall be done from any workshop within a radius of 5KM from GE(U) Chm.
61Demolition and removing from site old PCC and Material and Labour for Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate (mass concrete) for pump set bed including necessary form workcomplete all as specified and directed.
62S & F in replacement rolled mild steel channel, angle or tee sections, fixed independently, without connection plate, etc Fe-290 (Gde E-165) including nuts, bolts and washers for base frame of motor pump set, drilling of holes of suitable size for bolts & painting with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge
63Supply and fixingin replacement duty contactor 10 KVAR Inbuilt 1 NO/NC auxiliary contact complete all as specified and as directed by Engineer-in-charge.
64Material labour for finding minor fault in the main panel and providing in replacement worn out small control fuses, indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable all as specified and directed
65Supply and fixing in replacement HRC Fuse 250/200/150 Amps
66Supply and fixing in replacement CT of 300/5 including complete wiring.
67Supply and fixing in replacement CT of 200/5 including complete wiring.
68Supply and fix in replacement 3 pole power contactor MNX-18 Ampcomplete all as specified and directed.
69Supply and fix in replacement 3 pole power contactor MNX-A2complete all as specified and directed.
70Supply and fix in replacement 3 pole power contactorMNX-A1 complete all as specified and directed.
71Supply and fixing in replacement MCCB, triplepole, 125 Amp 415 volts. 50 Hz breaking capacity not less than 35 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icucomplete all as specified and as directed
72Supply and fixing in replacement MCCB, triplepole, 63 Amp 415 volts. 50 Hz breaking capacity not less than 35 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icucomplete all as specified and as directed
73Supply and fixing in replacement MCCB, triplepole, 160 Amp 415 volts. 50 Hz breaking capacity not less than 35 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icucomplete all as specified and as directed
74Dismantalling ofexisting cable and Supply, laying and testingPVC cable with Aluminium conductor , galvanised steel strip armoured, heavy duty LT power cables, 1100 volts grade cross sectional area70 sqmm 3 core including lux of cable complete all as specified and directed.
75Dismantalling ofexisting cable and Supply, laying and testingPVC cable with copper conductor , heavy duty LT power cables, 1100 volts grade cross sectional area10 sqmm three run including lux of cable complete all as specified and directed.
76Supplying and fixing in replacement MS Double Door Glass Cabinet for housing Hose reel, nozzle etc. of size 800x600x250 mm complete all as specified and directed by Engineer-in-Charge.
77S & F in replacement maintenance free lead acid sealed lead accumilater (SMF) 12 volts 100 Ah (battery) complete all as specified and as directed.
78Supply & fix in replacement offire brigade inlet 2way with painting in red colour & fixing arrangement complete all as specified and directed.
79Supply & fix in replacement ofHydrant valve single headed65 mm bore including flange, washer, and nut and bolt complete all as specified.
80Supply & fix in replacement ofHydrant valve double headed65 mm bore including flange, washer, and nut and bolt complete all as specified.
81Supply & fix in replacement ofAir Cushion tank with relief valve 200 mm with painting in red colour & fixing arrangement complete all as specified and directed.
82Supply & fix in replacement fire hydrant post/stand post 80 mm dia GI/MS both flanged type 1.5 mtr height with landing valve SS type B of 63 mm dia, single headed 3 waycomplete with painting in red colour & fixing arrangement complete all as specified and directed.
83Supply and fix in replacement CI butteryfly valveof size 150 mm ,screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions.complete all as specified and directed.
84Supply and fix in replacement CI butteryfly valveof size 100 mm ,screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions.complete all as specified and directed.
85Supply and fix in replacement CI butteryfly valveof size 80 mm ,screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions.complete all as specified and directed.
86Supply & Fixing in replacement cast iron Non Return Valve (NRV) swing check type, double flanged/butt end welded with bolted cover design of size 150 mm complete all as specified and directed.
87Supply & Fixing in replacement cast iron Non Return Valve (NRV) swing check type, double flanged/butt end welded with bolted cover design of size 100 mm complete all as specified and directed.
88Supply & Fixing in replacement cast iron Non Return Valve (NRV) swing check type, double flanged/butt end welded with bolted cover design of size 80 mm complete all as specified and directed.
89Supply & Fixing in replacement of 80 mm dia sluice valve cast iron body heavy duty class PN 1.6 , ISI marked (IS-14848) both end flanged, with stainless steelspindle,with cast iron hand wheel, including jointing material like rubber insertaion sheet 3 mm thick, bolt, nuts and fixed to pipe line, testing complete all as specified and directed.
90Supply & Fixing in replacement of 100 mm dia sluice valve cast iron body heavy duty class PN 1.6 , ISI marked (IS-14848) both end flanged, with stainless steelspindle,with cast iron hand wheel, including jointing material like rubber insertaion sheet 3 mm thick, bolt, nuts and fixed to pipe line, testing complete all as specified and directed.
91Supply,Installation,Testing and Commissioning in replacement of sprinkle glass bulb type (standard response ) as per IS 15/06/TAC guidline 68 Degree temperature rating pendent type complete all as specified and directed.
92Supply & Fixing in replacement of Adressable electronic sounderwith all required accessories for mounting complete all as specified and directed.
93Supply & Fixing in replacement of Automatic star delta starter 3 phase, 50 Hz, 415 Vincluding 34-51 Amp relay and 50 Amp contactor with all connecting accessories suitable for 45KW/60HP motor pump and mounting complete all as specified and directed.
94Material and Labour for pumping out ofwater from the 50000 liter capacity under ground sumpby means of suitable pumping set of appropriate capacity and thorough cleaning of the sump by rubbing, scrapping the surfaces and taking out all the foreign materials, silt, mud, sludge etc from the sump including vegitation from the unit and disposing offatlow laying area, distance not less than 500 mtrs and applying two coats of white wash on the entire internal surfacescomplete all as specified and directed.
95Note-(a). Necessary T&P , pumping set, pipes etc shall be arranged by the contractor. Required safety equipments such as hand gloves, headgears, masks, gum boots, oxygen gas cylinders etc shall also be arranged by the contractor. Labour trained in cleaning of sewerage sumps shall only be deployed to carry out the above job. Entire responsibility for safety of the deployed labour shall be of the contractor and deptt shall not be responsible for any mishappening or any type of loss occured during the execution of above job. Unit rate quoted shall be deemed to include the cost of all the above factors and no extra payment shall be made for the same.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail