Tender For Repairs/Replacement And Maintenance To U/S Parts Of Central Ac Plants Of Various Buildings In Technical Area Under Age (I) Rnd, Nstl, Visakhapatnam., visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Tender For Repairs/Replacement And Maintenance To U/S Parts Of Central Ac Plants Of Various Buildings In Technical Area Under Age (I) Rnd, Nstl, Visakhapatnam.. Submission Date for this Tender is 25-01-2024. HVAC Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41460945
Tender For Repairs/Replacement And Maintenance To U/S Parts Of Central Ac Plants Of Various Buildings In Technical Area Under Age (I) Rnd, Nstl, Visakhapatnam.
Open Tender
Indian
Andhra Pradesh
visakhapatnam
25-01-2024

Tender Details

Tender For Repairs/Replacement And Maintenance To U/S Parts Of Central Ac Plants Of Various Buildings In Technical Area Under Age (I) Rnd, Nstl, Visakhapatnam.

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: REPAIRS/ REPLACEMENT AND MAINTENANCE TO U/S PARTS OF CENTRAL AC PLANTS IN VARIOUS BUILDINGS IN TECH AREA UNDER AGE (I) R&D NSTL, VISAKHAPATNAM
Sl. No. Item Description
1M&L for cleaning/ servicing the cooling coil of 35 TR (2 x 35 TR) capacity plant at Manasi AHU ofby air pressure method using air blower and cleaning the cooling coil with suitable cleaning agent, cleaning the AHU base tray completely and applying one coat of synthetic enamel paint inside the base tray, including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter, replacement of unserviceable V belts etc. all as directed. Note:- V belts shall be measured and paid separately as "Supply only" under respective items of this Schedule.
2All as per Item No. 1 herein before but for 70 TR (3 x 35TR) capacity plant at C&G
3All as per Item No. 1 herein before but for 260 TR / 280 TRcapacity plant at Talwar / CNC
4M & L for cleaning/ servicing of cooling tower, natural draught type/ FRP type of 35 TR (2x35TR) Capacity AC Plant at Manasi including cleaning of wooden/ PVC/ FRP louvers by scraping inside and outside, cleaning of water tank, cleaning and replacement of damaged/ choked nozzles, replacement of PVC pipe n. exc. 3 mtr in length; arranging, refixing in position of all louvers in correct manner and applying one coat of black bituminous paint inside and outside of water tank, cleaning of CT Fan blades, replacement of corroded nuts and bolts as per existing sizeincluding replacement of damaged/ broken louvers and unserviceable nozzles all as specified and as directed.
5All as per Item No. 4 herein before but for 70 TR (3 x 35TR) capacity plant at C&G
6All as per Item No. 4 herein before but for 260/ 280 TR capacity plant at Talwar / CNC
7M & L for complete leak testing the entire central AC plant of anycapcity up to 60TRper unit consisting of compressors, condensers, chillers, AHUs with connected chilled piping, expansion valves and all accessories by flushing out the refrigerant gas present in the system, pumping Nitrogen gas at requisite pressure, locating leak positions, rectifying the leaks, including pressure testing and holding the pressure for 48 Hrs for observation for any pressure drop in the system and flushing out the complete system on rectification of leaks if any,vacuumising & de-hydration the complete system with heavy duty vacuum pump and removal of moisture and other foreign particles from the system complete including checking of all safety controls and parameters, testing & commissioning ofthe AC plant after charging the refrigerant gas all as directed by the Engineer-in-Charge. [Note: Supply & charging refrigerant gas will be measured and paid separately]
8M & L for complete leak testing the entire central AC plant of anycapcity above 60TR and up to140 TRper unit consisting of compressors, condensers, chillers, AHUs with connected chilled piping, expansion valves and all accessories by flushing out the refrigerant gas present in the system, pumping Nitrogen gas at requisite pressure, locating leak positions, rectifying the leaks, including pressure testing and holding the pressure for 48 Hrs for observation for any pressure drop in the system and flushing out the complete system on rectification of leaks if any,vacuumising & de-hydration the complete system with heavy duty vacuum pump and removal of moisture and other foreign particles from the system complete including checking of all safety controls and parameters, testing & commissioning ofthe AC plant after charging the refrigerant gas all as directed by the Engineer-in-Charge. [Note: Supply & charging refrigerant gas will be measured and paid separately]
9M & L for de-scaling the condenser unit, shell and tube type of 35TR capacity by circulating the approved cleaning agent / diluted hydrochloric acid at the appropriate ratio depending up on the scale deposits till removal inside the copper tube by means of circulating the de-scaling chemical through condenser by pressure feeding method after disconnecting condenser water lines, opening the end covers, scraping/cleaning the condenser water tubing, removing the scales and refixing the dismantled part, end cover with 3mm thick rubber gasket set, re-connecting with the system etc. including minor repairs all as specified and as directed.
10All as per Item No.9 herein before but of 130 TR capacity
11All as per Item No. 9 herein before but of 140 TR capacity
12M&L for Disconnecting electrically and mechanically mono-block pump set of 15 to 20 HP capacity of any make from the existing position by arranging dummy plates to suction and delivery line, removing from the existing position, opening up, varnishing to stator winding with class I varnish, heating/ baking the same, removal of damaged motor bearing, cleaning the rotor and re assembling the motor, cleaning the impeller of pump, supply & replacement of shaft bearings, gland rope, gland bolts &nuts, greasing the pump bearing, fixing back at original location with proper alignment, connecting and testing complete all as specified.
13All as per Item No. 12 herein before but of 10 to 12.5 HP capacity
14All as per Item No. 12 herein before but of 5 / 7.5 HP capacity
15M & L for disconnecting/ Dismantlig (electrically & mechanically) 3 phase, 440 volts, 50 Hz electrical motor from the monoblock pump set of 20 HP capacity and shifting to workshop, opening the motor end cover, taking ou trotor, taking out burnt stator winding, cleaning the stator and rewinding the motor with appropriate gauge, weight and turns of super enamelled copper wire using proper insulating material, varnishing with Class-I varnish, heating/ baking, reassembling the motor completely and brought back to site, fixing back duly coupled with the pump in prope aignment, connecting and testing complete all as specified. Note: Insulation of wiondng shall be Class "B" upto 7.5 HP and Class "F" for 10 HP and above.
16All as per Item No 15 here-in-before but of 10 HP Capacity
17All as per Item No 15 here-in-before but of 5/7.5 HP Capacity
18Supply only Wedge (V) Belts B - 134 for compressor & motor/ AHU & motor. [Make: Fenner/ Yule/ ContiTech]
19Supply only Wedge (V) Belts B - 95 for compressor & motor/ AHU & motor. [Make: Fenner/ Yule/ ContiTech]
20Supply only Wedge (V) Belts B-2253 LP /B87 for compressor & motor/ AHU & motor. [Make: Fenner/ Yule/ ContiTech]
21S&F in repairs Single phase preventer Heavy duty relay for protection against single phasing, phase reversal condition, unbalance condition, with inbuilt timer working on 440V, 50Hz power supply complete all as specified and directed. [Make:Minilec 3NA-30-323 or equivalent in Siemens]
22S&F in repairs electronic timer working on 160V to 500V for time delay 3-30 sec to 12-120 sec. [Make: Select/ L&T/ GIC]
23S&FStarter Push Button switch with 1 NO + 1 NC complete working on DC/ AC supply up to 16 Amps capacity by removing of the defective unit all as specified and as directed. [Make: L&T ESBEE/ Siemens]
24S&F in repairs 4 pole contactors AC operated rating at 415 Volts, AC1 45 Amps rating with 2NO + 2NC auxiliary contacts with operatabe coil voltage 24 volts to 415 volts AC/DC with front/ side mounted Add On blocks as per site requirement.[Make: ABB/ Siemens/ Schneider/ legrad
25All as per Item No. 24 herein before but of AC1 rating 30 Amps
26All as per Item No. 24 herein before but of AC1 rating 60 Amps
27S&F in repairs Thermal Overload relay, 18 to 42 Amps, direct mounted on contactors [TA42DU series of make: ABB or equivalent in GE/ scheider
28S&F in repairs Thermal Overload relay, 22 to 80 Amps, direct mounted on contactors [TA75DU series of make: ABB or equivalent in GE/ scheider
29Supply only Refrigerant gas "R- 22" in manufacturer"s sealed cylinder.
30Supply only Refrigerant gas "R- 134a"in manufacturer"s sealed cylinder. Note for Sl. item No 29 & 30:- (i) Empty cylinder will be returned to contractor on completion of work (ii) Net weight of refrigerant gas shall be measured and paid under these items.
31Supply onlyfilling of compressor oil suitable for compressor of Make: Carrier all as directed by Engr-in-charge.
32Supply onlyfilling of compressor oil suitable for compressor of Make: Voltas all as directed by Engr-in-charge.
33Supply and fixingof PCB board with flexible cards by replacing the damaged/ worn-out electronic components/ ICs with heat sinks, programming automation complete for Central AC plants of various capacities from 70 TR to 160 TR complete including testing and commissioning all as directed.
34S&F in repairs pneumatic safety valve for condensers of central AC plants of capacity 35 /130 / 140 TR. [Make: Castle/ Brassolite/ Henry]
35S&F in repairs flow control limit switch/ sensor as per the existing make/ model complete all as specified and as directed. [Make: Castle/ Rapid controls/ Honeywell]
36Supply and fixing of water pressure meter dial type up to 7 Kg/cm2 complete all as specified and directed. Make: Guru/Danfoss
37Supply and fixing oftemperature meter dail type with stop valve o to 30 degree cebntigrade with complete acessories by removing of the old unserviceable meter complete all as specified and directed. Make: H- guru / danfoss/ universal
38Removal of the damaged HP cut out, supply and fixing of High Pressure cut out on the compressed / pressurised gas lines complete all as specified and directed.
39Removal of the damaged LP cut out, supply and fixing of Low Pressure cut out on the compressed / pressurised gas lines complete all as specified and directed.
40Removing of the defective unserviceable temperature sensor and supply and fixing oftemprature sensor / thermostat controller along with necessary controll wiring and acessories. Make: Simens/ Honey well
41Removing of the defective unserviceable humidity sensor and supply and fixing of humidity sensor/ controlleralong with necessary controll wiring and acessories. Make: Simens/ Honey well
42Supply only HRC fuses suitable for Screw compressor control panel of capacity 130 TR suitable
43Disconnection and removing the LTcable connection from the Air Circuit breakers of capacity up to 1600 Amps AC 440 volts from existing LT panel including Complete Servicing of ACB for smooth functioning and operation withrepair/replacement of worn out parts such as Switches, Arcing contacts, Main contacts, Jaw contacts, tripping coil, charging motor, relays etc with new spare parts suitable for the existing ACB"s make,specifications complete and refixing the same in original position, testing complete all as specified and as directed by Engineer in charge. Make of existing ACB"s: C & S / Note:- (i)Spares required for servicing are measued and paid separately under relevant items.
44Supply only Isolating Contacts 800/ 1600 A suitable for LT ACBs
45Supply only shunt trip coil 230/ 440 Volts suitable for LT ACBs
46Supply only UVcoil 230/ 440 Volts suitable for LT ACBs
47Supply only Rack-in Rack-out mechanism suitable for LT ACBs
48Disconnection and removing the unserveciable MCCB & Supply and fix new MCCB with thermal-magnetic release Conforms to IS/IEC 60947-2 & IEC 60947-24 pole ,415 V ,400 A , 50 Hz , breaking capacity of 36 KA , complete all as directed by Engineer in charge.Make : scheinder, ABB,Legrand,Siemens,L&T
49All as per item No 48but of capacity 250 A , 36 KA
50All as per item No 48 but of capacity 200 A , 36 KA
51M&L for Preparation of old painted surface of scrapping of existing cooling tower & connected itemsby applying two coats of synthetic enamel paint over a coat of zinc chrome primer on existingcomplete all as specified and directed by Engr-in-charge.
52M&L for Preparation of old painted surface of scrapping including valves, strainers etc and applying two coats of synthetic enamel paint over a coat of zinc chrome primer on existing pipe line surfacescomplete all as specified and directed by Engr-in-charge.
53M&L for disconnecting the existing rusted MS pipe line of any size from their existing position including all accessoriescomplete all specified and directed by Eng in charge.
54S&F MSpipe line of 125 mm size
55S&F MSpipe line of 150 mm size
56S&F in repairs gun metal Ball vales 15mm dia with screwed ends fixed complete all as directed. [Make: Leader/ Zoloto/ Lakshmi/ Sakthi]
57All as per item 55 above herein before but 25 mm dia
58S&F 25mm bore ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed in repairs. [Make: Leader/ Zoloto/ Lakshmi/ Sakthi]
59Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
60Tubes, "light grade" galvanised of size 25 mm bore ,with all fitting and fixed complete to walls and ceilings or laid in floors.
61Tubes, "light grade" galvanised of size 40 mm bore ,with all fitting and fixed complete to walls and ceilings or laid in floors.
62S&F of air filter with aluminium frame for HV AC AHU of 10 micron for AC plant 70 TR (2x35 TR) Capacity plant at Mansi ( filter size-610x610x50mm)
63S&F of air filter with aluminium frame for HV AC AHU of 10 micron for AC plant 70 TR (3x35 TR) Capacity plant at C&G ( filter size-610x610x50mm)
64S&F of air filter with aluminium frame for HV AC AHU of 10 micron for AC plant260 TRCapacity plant atTalwari ( filter size-610x610x50mm)
65S&F of air filter with aluminium frame for HV AC AHU of 10 micron for AC plant 280 TR Capacity plant at C&C ( filter size-610x610x50mm)
Disclaimer :