Tender For Construction Of Proposed Swahid Smarak Khetra At Pachim Boragaon (Separable Items), guwahati-Assam

Public Works Department-PWD has published Tender For Construction Of Proposed Swahid Smarak Khetra At Pachim Boragaon (Separable Items). Submission Date for this Tender is 24-01-2024. Building Work Tenders in guwahati Assam. Bidders can get complete Tender details and download the document.




Tender Notice

41456952
Corrigendum : Tender For Construction Of Proposed Swahid Smarak Khetra At Pachim Boragaon (Separable Items)
Open Tender
Indian
Assam
guwahati
24-01-2024

Tender Details

Construction Of Proposed Swahid Smarak Khetra At Pachim Boragaon ( Separable Items ) - 1 Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1) UNIFORM PILE Concrete Grade M25 Pile dia 400 mm 2 Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) TMT bar made ofPrimary producer (From Primary producer) 3 Demolishing R.C.C./ P.C.C. pile head of different diameters carefully without disturbing the remaining portion of the pile including opening out of the pile head to be demolished by excavating the earth upto required depth and clearing the debris as directed. 4 Empty boring for specified diameter piles from ground level to cut-off level. d) Pile Dia 400 mm 5 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil 6 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In prop 1cement: 3 sand :6 coarse aggregate by volume 7 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details,ying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). ISI approved super ductile TMT Bar.TMT corrosion Resistant. 8 Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. 9 Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. 10 Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)(I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 grade concrete or Prop. 1:1.5:3 11 In super structure from plinth level up to 1st floor level.Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. N) Without using admixture, plasticiser M20 grade concrete 12 Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of N) Without using admixture, plasticiserM20 grade concrete or Prop. 1:1.5:3 13 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank 14 Sides of tie beams, grade beams etc. at or below ground level.(b) Using 25mm thick plank 15 Columns, Pillars, Posts & Strut Using 25mm thick plank 16 Sides and soffits of beams, beam haunchings , cantilever giders , bressumers , lintels and horizontal ties. Using 25mm thick plank 17 Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)25mm thk. Plank 18 Formwork Flat surfaces such as soffits of suspended floors , roofs landing , cantilaever slabs chajjas , balconies and like 25mm thk. Plank 19 Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering complete.Brick on flat soiling. 20 Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.In Sub-structure upto plinth level including dewatering if necessaryIn proportion 1:4. 21 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately) 112mm thick brick wallIn cement mortar in proportion 1:4. (1 cement:4 sand) 22 Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding, providing face stone, through stone and centering including racking of joints, curing and supplying and all carriage of stone as directed including payment of forest royalty and sales tax and carriage. (a) Random Rubble Masonry 23 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises orrounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. In cement mortar 1:4 24 15 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On fair side In cement mortar 1:4 25 On rough side In cement mortar 1:4 26 20 mm thick Cement plaster in two coats on single or half brickwalls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. On rough side (backing coat 15 mm and finishing coat 5mm thick) In cement mortar 1:4 27 B) On fair side (backing coat 10 mm and finishing coat 10mm thick) In cement mortar 1:4 28 Supplying and laying of permanent wall finish for interior and exterior walls with surface coating of Heritage Surface Texture of Bakelite Hylam Limited for all types of buildings at all levels as specified and directed by the department. Granules (Code : HGR) 29 Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. 30 Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem “Rakshak” brand of required shade by thinning 11ltr. of paint with 750ml of water to give an even shade after thoroughly brooming the surface to remove all dirt and remains of loose powdered materials as specified and directed by the department. Asian paint / Berger paint / ICI ect. 31 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) on new surface to give and even shade after thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. 32 Providingtwo coats of J.K. wall putty (white cementbased putty for concrete /mortar walls and ceiling both internal And external) after removing all loosely Adhering materials from the wall surface With the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coates is maximum 1.5mm). 33 Applying priming coat over newwood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughlycleaningoil, grease, dirt snd other foreign matter , sand papering and knotting. With ready mixed paint , wood primer (white). 34 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.Surfaces over 100mm in width or girth.General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). 35 Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.a). With ready mixed red-lead/ red oxide primer. 36 Applying primary coat over new steel and other metal surface upto 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. With ready mixed red-lead/ red oxide primer. 37 Painting two coats (excluding priming coat) on new steel and other metal surface with alluminium paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) and brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.(a).Surfaces over 100mm in width or girth. 38 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.(ii).Surfaces up to 100mm in width or girth.a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). 39 18 mm thick marble stone tiles in flooring including risers and treads of steps, skirting, dado, walls, pillars laid with 10 mm thick base of cement plaster in prop.1:3 ( I cement : 3 coarse sand) and jointed with grey cement slurryincluding rubbing and polishing complete with marble tiles of specified quality and shade at all levels.(a) With 18mm thick marble stone tiles of size 600mm x 600 mm Dungri slab 40 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make Of size 600mmx600mm and above 41 Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). Delux rangeSomany/ Orient/Nitco/Varmora Make Of size 300mmx450mm and above 42 Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. CERAMIC i)Normal range (Sizes 300 mm x 300mm and above)Orient made:Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate 43 Providing polished SUNROCK-Hi CTS/ MULTIWYNtiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (a) SUNROCKHi CTS TILES Well, Chocolate, Diamond Square, Ramp, Beach Sand (300x300) mm 44 Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade. 45 Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. a) Decorative type face panel and block board core.(i) 40 mm thick . 46 Providing, fitting and fixingM.S.grillof required pattern for windows/ clerestory windows/ openingwith M.S. flatsat required spacingin frame all round,squre or round M.S.bars with round headed bolts and nuts or screws.I .Plain grill(c) Fixed to Brickwork/P.C.C/R.C.C. 47 Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.(b)3 Track sliding window(i)6mm clear glass 48 Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mmand bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete etc complete as specified and directed by the department at all levels.(a) with 12 mm thick toughened glass 49 Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid separately).Side hung and Top hung windows and ventilators5mm frosted glass 50 Providing, fitting and fixing aluminium curtain wall on the exterior face of building fitting to concrete member by drilling hole fixing by brass screw fabricated with coloured anodised aluminium section of approved brand 101mm x 55mm x 2mm by providing jointing angles including providing coloured reflectory type glass 6mm thick fitted with aluminium at all levels. 51 Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with twoequal flanges of15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary).12.5mm thick 52 Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint. 53 Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately) .(a) 1.25mm thick sheetSize 125mm x 60mm (Double rebate) 54 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes , channels , plates etc., including welding , grinding , buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete , i.e. fixing the railing with necessary accessories & stainless steel dash fasteners ,stainless steel bolts etc., of required size , on the top of the floor or the side of waistslab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of stainless steel member is be considered.No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered) 55 Supplying, fitting, fixing electrocoloured iron fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete. Sliding door boltsi) 300mm x 16mm 56 Tower boltsi) 250mm x 10mm 57 MS door handles i) 150 mm 58 MS butt hingeI) Heavy typei) 50mm x 40mm x 2.5mm 59 ii) 75mm x 60mm x 3.15 60 Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department.A) Godreja) Single Speed Door Closer( size166.5x 48mmx 67mm)-Model C071 61 Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished. 62 Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. 63 Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. 64 Providing plain Polycarbonate transparent sheet roofing at all levels with self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) (iii) 3.00 mm thick 65 Providing, fitting, hoisting and fixing of roof trusses fabricated out ofcombination of anytwo or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997 66 EUROPEAN TYPE WATER CLOSETC) Jaquar make a) WhiteProviding fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)(ii) Size 550 x 350 x 360 (Cat No.CNS-WHT-WS02) (inclusive of seat cover) 67 Supplying, fiting and fixing PVC flushing cisternwith all internal fittingswith CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)i) Parryware make a) WhiteEconomy Single Flush (Cat No.C8090/C8055) 68 Providingfitting and fixing vitreous china flat back type lippedfront urinal basinwith standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting offittings and brackets, cutting andmaking good the walls& floors wherever required.(B) Hindware MakeFB 460 x 350 x 260 (Cat. No.60001) 69 Providing vitreous Chinawash basinwith CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)Basin (without pedestal) Hindware Make(a) White(ii) Viking 550 x 400(Cat.No.10008) 70 Providing fitting & fixinglaboratory sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipeetc. complete includingpainting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately.Hindware Make(a) White (iii) Size 450 x 300 x 180 (Cat.No.50001) 71 Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified. 72 Providing fitting and fixing Glass Shelf complete as directed and specified.Glass shelf with C.P. guard railAgmeco make(e) Dolfee (Cat.No.DE-00104) 73 Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified (a) Parryware MakeWall Soap tray (Cat. No.C9951) 74 Providing, fitting and fixing CP towel rail complete as directed and specified. Sona make(Cat. No.C9951) (iii) Towel rail Diplomat 600mm long (Cat.No.TR-0605) 75 Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified.Jaquar make(i) Continental (Cat.No. ACN-1191N) 76 1.33Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified.Sona make(i) Bottle trap indian 32mm (Cat. No.BT-0751) 77 Supplying, fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required andcomplete at all levels including below G.L as directed and specified. In exposed surfaces or tranches.150 mm dia. 78 100mm dia. 79 50mm dia. 80 Concealed by chiselling or breaking brick wall/C.C./R.C.Cand making good to the damages.100mm dia. 81 50mm dia. 82 Supplying, fitting and fixing H.C.I bend with door including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified.In exposed surfaces or in trenches.150mm dia. 83 100mm dia. 84 50mm dia. 85 Concealed by chiselling or breaking brick wall/C.C./R.C.Cand making good to the damages.100mm dia. 86 Supplying,fitting and fixing H.C.I plain bend including bolts and nuts and other fittings as requiredcomplete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. .150mm dia. 87 100mm dia. 88 50mm dia. 89 Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining ,fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. In exposed surfaces or in trenches. . . 160mm dia. 90 110mm dia. 91 63 mm dia. 92 Supplying fiting and fixing 87.5 degree PVC bendwith doorof (Supreme/Prince) or other ISI approvedincluding joining , fittingand fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 160mm dia. 93 110mm dia. 94 75 mm dia. 95 Providing fitting and fixing PVC cowel of ISI make completeas directed and specified.110mm dia. PVC cowel of ISI make 96 Providing fiting & fixingC.I. Grating to the floors complete asdirected and specified.110mm dia 97 Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approvedincluding joining , fittingand fixing etc. as necessary complete at all levels including below G.L. as directed and specified.In exposed surfaces or in trenches. .(i) 160mm x 110 mm 98 Supplying, fitting and fixing H.C.I plain single equal junction/plain tee including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified.In exposed surfaces or in trenches. (ii) 100mm dia. 99 Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table. 100 Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. 101 Providingfitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 19 Kg. weight complete as directed and specified 102 Providingfitting and fixing (600x600)mm90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified 103 upplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary R brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified.Exposed or in trenches. SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) 50 mm dia 104 40 mm dia 105 32 mm dia 106 25 mm dia 107 Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.20 mm dia 108 15 mm dia 109 Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary R brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. Exposed on walls 50 mm dia (Medium)Using Tata make 110 40 mm dia (Medium)Using Tata make 111 32 mm dia (Medium)Using Tata make 112 25 mm dia (Medium)Using Tata make 113 20 mm dia (Medium)Using Tata make 114 Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary R brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. Exposed or in trenchesSUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)15mm diameter 115 20mm diameter 116 Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Jaquare make Continental /ClarionStandard 117 Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar15mm dia Male / Female (long thread) 118 Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately)Brass stop cock (heavy) ofSant make15mm dia 119 20mm dia 120 25mm dia 121 32mm dia 122 40mm dia 123 50mm dia 124 Supplying fitting and fixing push bib cock 15mm dia complete as directed and specified as follows. (pipes will be measured and paid separately).a) C.P.C.H.Light type 125 Heavy type 126 Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed.ii) Jaguar make Continental 127 Long neck with areator 128 Agmeco(classic) Elbow action pillar cock (Agmeco)MS-491/ Heavy Duty 129 Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) Jaquar brand Sink cock with raised J shaped swinging spout 130 Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Makeas specified and directed.50mm dia 131 Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes2000 Lt capacitySintex make 132 Wiring for light/ fan/ call bell point with2x1.5 sq. mm.P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) inrecessed conduit wiring system with2 mm thick 20mm dia rigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)completeSP upto 3.00 metre length. 133 MP upto 6.00 metre length. 134 LP upto 10.00 metre length. 135 Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete.SP upto 3.00 metre length. 136 MP upto 6.00 metre length. 137 LP upto 10.00 metre length. 138 Wiring for 5 pin 16 Amps power plug point with4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessedconduit wiring system including earth continuity with2.5 sq. mmcableto the 3rd pin of the socketas required complete with 2 mm thick20 mm. dia.rigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) SP upto10.00 metre length. 139 MP upto 15.00 metre length. 140 LP upto 20.00 metre length. 141 Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete.SP upto 3.00 metre length. 142 MP upto 6.00 metre length. 143 LP upto 10.00 metre length. 144 Wiring to 5 a pin 6 Amps plug point with1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) inrecessed2 mm thickrigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)wiring system including earth continuity with1.5 sq. mm.cable to third pin of the plug socket etc. as required complete. SP upto10.00 metre length. 145 MP upto 15.00 metre length. 146 LP upto 20.00 metre length. 147 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedconduit wiring system includingand fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switchboard (I.S.I. mark withphenolic laminated sheet cover earth continuity with 2.5 sq. mm cableto the 3rd pin of the socketas required complete with20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Long point up to 10.00 metre. Length. 148 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedconduit wiring system includingand fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switchboard (I.S.I. mark withphenolic laminated sheet cover earth continuity with 2.5 sq. mm cableto the 3rd pin of the socketas required complete with20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Extra long pt. upto 15.00 mtr. Length 149 Extra long pt. upto 20.00 mtr. Length 150 Extra long pt. upto 25.00 mtr. Length 151 Wiring to 5 a pin 6 Amps plug point with1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) inrecessed2 mm thickrigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)wiring system including earth continuity with1.5 sq. mm.cable to third pin of the plug socket etc. as required complete. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit. 152 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit. 153 With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cablein 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit. 154 Wiring to 5 a pin 6 Amps plug point with1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) inrecessed2 mm thickrigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)wiring system including earth continuity with1.5 sq. mm.cable to third pin of the plug socket etc. as required complete.With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit. 155 Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department. 156 SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department. 157 Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department. 158 Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department. 159 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including earth continuity in surface/ recessedPVC20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system .With 3 x 16 sq. mm. + earth continuity with2x 10 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit. 160 Wiring for 5 pin 6 amp plug with 1.5 sq mmP.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socketas required on the switch board in surface/ recessedP.V.C. conduit wiring system. When fitted on same board of light and fan. 161 Supplying and fixing of polished Brass Bracket of 18 S.W.G,25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp 162 CE Approv. 2 Supplying, installation, testing and Commission of the following indoor Decorative Surface mounted2 x 2 LEDdown lighter luminaries of model no-SM365C LED 32 -6500PSU OD GR / SM365C LED 32 -6500PSU OD GH / SM365C LED 32 -6500PSU OD GR /SM365C LED 32 -6500PSU OD WH/ LSVR01S036SC / LSVR01S0365SN / LSVR01S0365SW/ CRCO10S038HP57G1complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / Jaquar / Wipro make). 163 Supplying,installation,testing and Commission of the following indoor Surface Mounted and Suspended Luminaires LED Luminaires complete with all accessories such as driver etc. and necessary connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department CE. Apprv. Philips 24 W, Astra Surface & wall mounted LED batten Model BN150W LED20S-6500 PSE OD GR or equivalent as approved by the Deptt. 164 Supplying,installation,testing and Commission of the following LED lamp as directed by the department CE ApprvPhilips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt. 165 Supplying,installation,testing and Commission of the following indoor Recessed Mounted LED Luminaires complete with all accessories such as driver etc. In the flase ceiling type Armstronng /Gypsum or similar ceiling mouting with necessary support and connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department CE Apprv. Philips lighting luminaire 15 W GreenLED Model BBS170 1xDLED -5000 PSU WH/ BBS170 1xDLED -4000 PSU WH or GreenLED Square ModelBBS175 1xDLED -5000 PSU WH/ BBS175 1xDLED -4000 PSU WH or equivalent as approved by the Deptt. 166 Supplying with fitting and fixing of Foot lamp with Box and lamp holder in 3 module recessed system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. Without lamp. 167 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)in surface/ recessedsystem complete as per direction of department. 3 module 168 6 module 169 12 module 170 Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)front plate of suitable colour as per direction of department.3 module 171 6 module 172 12 module 173 Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department. 174 Supplying and fixing of polished Brass Bracket of 18 S.W.G,25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp 175 CE Apprv. Supplying, installation, testing and Commission of the following indoor Decorative Recess mountedLEDdown lighter luminaries of model no-LESP01R009XC / LESP01R009XN /LESP01R009XW / L00957R000 / L00940R000 /L00930R000/LD90-111 - XXX-65-XXcomplete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar/ LT / Wipro make). 176 Supplying and fixing of Jaquar or equivalent Philips/ Wipro LED wall light fittings complete with Shade, back plate including connection cable,as approved by the Deptt.s etc. as required. Linear LED Tube 12W 177 Supplying with fitting and fixing of Foot lamp with Box and lamp holder in 3 module recessed system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. Without lamp. 178 CE Apprv Supplying fitting & fixing of LED Bulb non-dimmable in the existing batten / angle holderas required and as directed by the department ( Jaquar or eqvt. make).6/b Prima Series Bulb 7W 179 CEAppr.Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department.10/b BN 021C LED 20 S PSU CW GR S2 180 CE Apprv. Supplying fitting & fixing of LED Kubik Batten tube light fitting 300mm lengthas required and as directed by the department ( Jaquar or eqvt. make).7/c kubik Series Batten tube fitting 20W 181 Supplying and fixing of Jaquar or equivalent Philips/ Wipro LED wall light fittings complete with Shade, back plate including connection cable,as approved by the Deptt.s etc. as required.3.23.3 LED Bulk Head 8W 182 CE Apprv Supplying,installation,testing and commissioning of the following integral flood lighting luminaires conforming to IP 65 / IP 66 suitable for vertical and horizontal mounting applications pressure die cast powder coated aluminium alloy housing with corrosion resistance powder coating using nano Technology transparent injection moulded poly carbonate UV stabilized diffuser having high impact strength to withstand min IK09 with high power LED and unique flood optics to ensure uniform light distribution and maintenance free system ideal for area lighting, high mast lighting, sports lighting and billboard. The luminaires should be equiped with external surge protection device to withstand 10 KV / 5KV including connection with 2.5 sqmm 3 core PVC insulated round copper conductor as required and as directed by the department.12/g BVP 410 LED 215 CW HE NB FG S4 XTFCL 183 Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete. 184 Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required. 185 Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete. 186 Supplying including fitting fixing of followingstar rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable,as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)ECBC1.1.1Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make 187 26/SB8.21 Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.8.21.2 120 watt electronic modular 5 step speed control2 - module 188 Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.Power Flow225 mm sweep (ORIENTmake) 189 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake)12 way SPN double door 190 Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake)4way TPN (4+12)double door 191 Supplying including fitting fixing of followingA.C. Wall fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. ORIENTmake or equivalent Ushamake Air Circulator wall fan 600 mm sweep Turbo force 192 Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.100 watt electronic modular 4 step speed control2 - module type 193 Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split typeair conditioner of the following capacity with cordless remote complete withindoor and outdoor unit, copper pipeand electrical connection as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department. 2 Ton capacity Voltage make 194 Supplying with fitting and fixingVoltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUSmake) 5.0 KVA Automatic Input 90-280 V Out put 200-240 V 195 Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. Overload Relay Range 16 - 25 Amps in 3 Module 196 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.ABB, Schneider MG, legrand, Hagermake) 8 way SPN double door 197 Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake)6way TPN (4+18)double door 198 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.1C Series 6 - 32 A 199 Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake) 6-32A 200 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DPRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 30mA sensitivity DP RCCB(ABB, Schneider MG, legrand, Hagermake) 40A 201 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4PRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.100/300mA sensitivity 4P RCCB(ABB, Schneider MG, legrand, Hagermake) 202 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4PRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity 4P RCCB6-32A 203 6-32A 204 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DPRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.30mA sensitivity DP RCCB40A6-32A 205 Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, neutral adjustable with earth fault protection Without enclosureof the following capacity complete with making necessary connection as approved, specified and directed by the deptt.50KA(ABB, Schneider, legrand, L&T, Siemens, C&Smake) 160A 206 Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.35M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and35mm X 35mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 6nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:20mm X 3mm4 strip copper Bus-Bar 0.6 M length each Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no Digital 3 Phase Ammeter Accuracy class 0.5- 1 noPilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no Voltmeter & Ammeter Selector Switch- 2 no 2 A Slide fuse unit - 3nos (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately) 207 Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.50M X 1.60MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and40mm X 40mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 400A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:40mm X 5mm 4 strip copper Bus - Bar 1.50 M length each Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no Digital 3 Phase Ammeter Accuracy class 0.5- 1 no Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 noVoltmeter & Ammeter Selector Switch- 2 no 2 A Slide fuse unit - 3nos(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately) 208 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DPRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 3P MCCB(Havells, HPL, Indo Asian make)63A 209 125A 210 Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch,through medium duty G.I. pipe(Tata/ Nezonemake or equivalent as approved by the Deptt)bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make):3&1/2core A2XFY70.00 Sq.mm.3 & 1/2 Core armoured U.G. cable 211 150.00 Sq.mm.3 & 1/2 Core armoured U.G. cable 212 Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch,through medium duty G.I. pipe(Tata/ Nezonemake or equivalent as approved by the Deptt)bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)150.00 Sq.mm 3&1/2 Core U.G. cable in65mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) 213 Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch,through medium duty G.I. pipe(Tata/ Nezonemake or equivalent as approved by the Deptt)bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 3&1/2core A2XWFY,A2XFY 70.00 Sq.mm 3&1/2 Core U.G. cable in65mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Jan-2024 Corrigendum Technical Bid 24-01-2024

Key Value

Document Fees
INR 9466 /-
EMD
INR 946645.0 /-
Tender Value
INR 4.73 Crore /-

BOQ Items

Name of Work: Construction of Proposed Swahid Smarak Khetra at Pachim Boragaon (Separable items)
Sl. No. Item Description
1Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1) UNIFORM PILE Concrete Grade M25 Pile dia 400 mm
2Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) TMT bar made ofPrimary producer (From Primary producer)
3Demolishing R.C.C./ P.C.C. pile head of different diameters carefully without disturbing the remaining portion of the pile including opening out of the pile head to be demolished by excavating the earth upto required depth and clearing the debris as directed.
4Empty boring for specified diameter piles from ground level to cut-off level. d) Pile Dia 400 mm
5Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil
6Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In prop 1cement: 3 sand :6 coarse aggregate by volume
7Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details,ying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). ISI approved super ductile TMT Bar. TMT corrosion Resistant.
8Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
9Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
10Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)(I) Using Mixer Machine(A) In substructure up to plinth levelFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 grade concrete or Prop. 1:1.5:3
11In super structure from plinth level up to 1st floor level.Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. N) Without using admixture, plasticiser M20 grade concrete
12Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of N) Without using admixture, plasticiser M20 grade concrete or Prop. 1:1.5:3
13Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
14Sides of tie beams, grade beams etc. at or below ground level.(b) Using 25mm thick plank
15Columns, Pillars, Posts & Strut Using 25mm thick plank
16Sides and soffits of beams, beam haunchings , cantilever giders , bressumers , lintels and horizontal ties. Using 25mm thick plank
17Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank) 25mm thk. Plank
18Formwork Flat surfaces such as soffits of suspended floors , roofs landing , cantilaever slabs chajjas , balconies and like 25mm thk. Plank
19Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering complete. Brick on flat soiling.
20Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed.In Sub-structure upto plinth level including dewatering if necessary In proportion 1:4.
211st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately) 112mm thick brick wall In cement mortar in proportion 1:4. (1 cement:4 sand)
22Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding, providing face stone, through stone and centering including racking of joints, curing and supplying and all carriage of stone as directed including payment of forest royalty and sales tax and carriage. (a) Random Rubble Masonry
2310 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises orrounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. In cement mortar 1:4
2415 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On fair side In cement mortar 1:4
25On rough side In cement mortar 1:4
2620 mm thick Cement plaster in two coats on single or half brickwalls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. On rough side (backing coat 15 mm and finishing coat 5mm thick) In cement mortar 1:4
27B) On fair side (backing coat 10 mm and finishing coat 10mm thick) In cement mortar 1:4
28Supplying and laying of permanent wall finish for interior and exterior walls with surface coating of Heritage Surface Texture of Bakelite Hylam Limited for all types of buildings at all levels as specified and directed by the department. Granules (Code : HGR)
29Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
30Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem “Rakshak” brand of required shade by thinning 11ltr. of paint with 750ml of water to give an even shade after thoroughly brooming the surface to remove all dirt and remains of loose powdered materials as specified and directed by the department. Asian paint / Berger paint / ICI ect.
31Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) on new surface to give and even shade after thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
32Providingtwo coats of J.K. wall putty (white cementbased putty for concrete /mortar walls and ceiling both internal And external) after removing all loosely Adhering materials from the wall surface With the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coates is maximum 1.5mm).
33Applying priming coat over newwood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughlycleaningoil, grease, dirt snd other foreign matter , sand papering and knotting. With ready mixed paint , wood primer (white).
34Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. Surfaces over 100mm in width or girth. General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
35Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.a). With ready mixed "red-lead/ red oxide" primer.
36Applying primary coat over new steel and other metal surface upto 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. With ready mixed "red-lead/ red oxide" primer.
37Painting two coats (excluding priming coat) on new steel and other metal surface with alluminium paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) and brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.(a).Surfaces over 100mm in width or girth.
38Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.(ii).Surfaces up to 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
3918 mm thick marble stone tiles in flooring including risers and treads of steps, skirting, dado, walls, pillars laid with 10 mm thick base of cement plaster in prop.1:3 ( I cement : 3 coarse sand) and jointed with grey cement slurryincluding rubbing and polishing complete with marble tiles of specified quality and shade at all levels.(a) With 18mm thick marble stone tiles of size 600mm x 600 mm Dungri slab
40Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make Of size 600mmx600mm and above
41Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). Delux range Somany/ Orient/Nitco/Varmora Make Of size 300mmx450mm and above
42Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. CERAMIC i)Normal range (Sizes 300 mm x 300mm and above) Orient made:Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
43Providing polished SUNROCK-Hi CTS/ MULTIWYNtiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (a) SUNROCKHi CTS TILES Well, Chocolate, Diamond Square, Ramp, Beach Sand (300x300) mm
44Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
45Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. a) Decorative type face panel and block board core. (i) 40 mm thick .
46Providing, fitting and fixingM.S.grillof required pattern for windows/ clerestory windows/ openingwith M.S. flatsat required spacingin frame all round,squre or round M.S.bars with round headed bolts and nuts or screws.I .Plain grill (c) Fixed to Brickwork/P.C.C/R.C.C.
47Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.(b)3 Track sliding window (i)6mm clear glass
48Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mmand bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete etc complete as specified and directed by the department at all levels. (a) with 12 mm thick toughened glass
49Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid separately). Side hung and Top hung windows and ventilators 5mm frosted glass
50Providing, fitting and fixing aluminium curtain wall on the exterior face of building fitting to concrete member by drilling hole fixing by brass screw fabricated with coloured anodised aluminium section of approved brand 101mm x 55mm x 2mm by providing jointing angles including providing coloured reflectory type glass 6mm thick fitted with aluminium at all levels.
51Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with twoequal flanges of15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). 12.5mm thick
52Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
53Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately) .(a) 1.25mm thick sheet Size 125mm x 60mm (Double rebate)
54Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes , channels , plates etc., including welding , grinding , buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete , i.e. fixing the railing with necessary accessories & stainless steel dash fasteners ,stainless steel bolts etc., of required size , on the top of the floor or the side of waistslab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of stainless steel member is be considered.No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
55Supplying, fitting, fixing electrocoloured iron fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete. Sliding door boltsi) 300mm x 16mm
56Tower boltsi) 250mm x 10mm
57MS door handles i) 150 mm
58MS butt hingeI) Heavy type i) 50mm x 40mm x 2.5mm
59ii) 75mm x 60mm x 3.15
60Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department. A) Godrej a) Single Speed Door Closer( size166.5x 48mmx 67mm)-Model C071
61Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
62Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
63Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
64Providing plain Polycarbonate transparent sheet roofing at all levels with self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) (iii) 3.00 mm thick
65Providing, fitting, hoisting and fixing of roof trusses fabricated out ofcombination of anytwo or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
66EUROPEAN TYPE WATER CLOSETC) Jaquar make a) White Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)(ii) Size 550 x 350 x 360 (Cat No.CNS-WHT-WS02) (inclusive of seat cover)
67Supplying, fiting and fixing PVC flushing cisternwith all internal fittingswith CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)i) Parryware make a) White Economy Single Flush (Cat No.C8090/C8055)
68Providingfitting and fixing vitreous china flat back type lippedfront urinal basinwith standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting offittings and brackets, cutting andmaking good the walls& floors wherever required.(B) Hindware Make FB 460 x 350 x 260 (Cat. No.60001)
69Providing vitreous Chinawash basinwith CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)Basin (without pedestal) Hindware Make(a) White(ii) Viking 550 x 400(Cat.No.10008)
70Providing fitting & fixinglaboratory sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipeetc. complete includingpainting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately. Hindware Make(a) White (iii) Size 450 x 300 x 180 (Cat.No.50001)
71Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
72Providing fitting and fixing Glass Shelf complete as directed and specified.Glass shelf with C.P. guard rail Agmeco make(e) Dolfee (Cat.No.DE-00104)
73Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified (a) Parryware Make Wall Soap tray (Cat. No.C9951)
74Providing, fitting and fixing CP towel rail complete as directed and specified. Sona make(Cat. No.C9951) (iii) Towel rail Diplomat 600mm long (Cat.No.TR-0605)
75Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. Jaquar make(i) Continental (Cat.No. ACN-1191N)
761.33Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. Sona make(i) Bottle trap indian 32mm (Cat. No.BT-0751)
77Supplying, fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required andcomplete at all levels including below G.L as directed and specified. In exposed surfaces or tranches. 150 mm dia.
78100mm dia.
7950mm dia.
80Concealed by chiselling or breaking brick wall/C.C./R.C.Cand making good to the damages. 100mm dia.
8150mm dia.
82Supplying, fitting and fixing H.C.I bend with door including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 150mm dia.
83100mm dia.
8450mm dia.
85Concealed by chiselling or breaking brick wall/C.C./R.C.Cand making good to the damages. 100mm dia.
86Supplying,fitting and fixing H.C.I plain bend including bolts and nuts and other fittings as requiredcomplete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. . 150mm dia.
87100mm dia.
8850mm dia.
89Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining ,fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. In exposed surfaces or in trenches. . . 160mm dia.
90110mm dia.
9163 mm dia.
92Supplying fiting and fixing 87.5 degree PVC bendwith doorof (Supreme/Prince) or other ISI approvedincluding joining , fittingand fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 160mm dia.
93110mm dia.
9475 mm dia.
95Providing fitting and fixing PVC cowel of ISI make completeas directed and specified. 110mm dia. PVC cowel of ISI make
96Providing fiting & fixingC.I. Grating to the floors complete asdirected and specified. 110mm dia
97Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approvedincluding joining , fittingand fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. .(i) 160mm x 110 mm
98Supplying, fitting and fixing H.C.I plain single equal junction/plain tee including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. (ii) 100mm dia.
99Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
100Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
101Providingfitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 19 Kg. weight complete as directed and specified
102Providingfitting and fixing (600x600)mm90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified
103upplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary "R" brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. Exposed or in trenches. SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) 50 mm dia
10440 mm dia
10532 mm dia
10625 mm dia
107Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. 20 mm dia
10815 mm dia
109Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. Exposed on walls 50 mm dia (Medium) Using Tata make
11040 mm dia (Medium) Using Tata make
11132 mm dia (Medium) Using Tata make
11225 mm dia (Medium) Using Tata make
11320 mm dia (Medium) Using Tata make
114Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary "R" brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) 15mm diameter
11520mm diameter
116Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Jaquare make Continental /Clarion Standard
117Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar 15mm dia Male / Female (long thread)
118Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) Brass stop cock (heavy) ofSant make 15mm dia
11920mm dia
12025mm dia
12132mm dia
12240mm dia
12350mm dia
124Supplying fitting and fixing push bib cock 15mm dia complete as directed and specified as follows. (pipes will be measured and paid separately).a) C.P.C.H. Light type
125Heavy type
126Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed.ii) Jaguar make Continental
127Long neck with areator
128Agmeco(classic) Elbow action pillar cock (Agmeco) MS-491/ Heavy Duty
129Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) Jaquar brand Sink cock with raised "J" shaped swinging spout
130Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Makeas specified and directed. 50mm dia
131Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes 2000 Lt capacity Sintex make
132Wiring for light/ fan/ call bell point with2x1.5 sq. mm.P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) inrecessed conduit wiring system with2 mm thick 20mm dia rigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)complete SP upto 3.00 metre length.
133MP upto 6.00 metre length.
134LP upto 10.00 metre length.
135Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete. SP upto 3.00 metre length.
136MP upto 6.00 metre length.
137LP upto 10.00 metre length.
138Wiring for 5 pin 16 Amps power plug point with4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessedconduit wiring system including earth continuity with2.5 sq. mmcableto the 3rd pin of the socketas required complete with 2 mm thick20 mm. dia.rigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) SP upto10.00 metre length.
139MP upto 15.00 metre length.
140LP upto 20.00 metre length.
141Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete. SP upto 3.00 metre length.
142MP upto 6.00 metre length.
143LP upto 10.00 metre length.
144Wiring to 5 a pin 6 Amps plug point with1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) inrecessed2 mm thickrigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)wiring system including earth continuity with1.5 sq. mm.cable to third pin of the plug socket etc. as required complete. SP upto10.00 metre length.
145MP upto 15.00 metre length.
146LP upto 20.00 metre length.
147Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedconduit wiring system includingand fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switchboard (I.S.I. mark withphenolic laminated sheet cover earth continuity with 2.5 sq. mm cableto the 3rd pin of the socketas required complete with20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Long point up to 10.00 metre. Length.
148Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedconduit wiring system includingand fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switchboard (I.S.I. mark withphenolic laminated sheet cover earth continuity with 2.5 sq. mm cableto the 3rd pin of the socketas required complete with20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Extra long pt. upto 15.00 mtr. Length
149Extra long pt. upto 20.00 mtr. Length
150Extra long pt. upto 25.00 mtr. Length
151Wiring to 5 a pin 6 Amps plug point with1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) inrecessed2 mm thickrigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)wiring system including earth continuity with1.5 sq. mm.cable to third pin of the plug socket etc. as required complete. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
152With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
153With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cablein 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
154Wiring to 5 a pin 6 Amps plug point with1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 withflexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) inrecessed2 mm thickrigidlow halogen SFT PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)wiring system including earth continuity with1.5 sq. mm.cable to third pin of the plug socket etc. as required complete. With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
155Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
156SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
157Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
158Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
159Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including earth continuity in surface/ recessedPVC20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system . With 3 x 16 sq. mm. + earth continuity with2x 10 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
160Wiring for 5 pin 6 amp plug with 1.5 sq mmP.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socketas required on the switch board in surface/ recessedP.V.C. conduit wiring system. When fitted on same board of light and fan.
161Supplying and fixing of polished Brass Bracket of 18 S.W.G,25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
162CE Approv. 2 Supplying, installation, testing and Commission of the following indoor Decorative Surface mounted2" x 2" LEDdown lighter luminaries of model no-SM365C LED 32 -6500PSU OD GR / SM365C LED 32 -6500PSU OD GH / SM365C LED 32 -6500PSU OD GR /SM365C LED 32 -6500PSU OD WH/ LSVR01S036SC / LSVR01S0365SN / LSVR01S0365SW/ CRCO10S038HP57G1complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / Jaquar / Wipro make).
163Supplying,installation,testing and Commission of the following indoor Surface Mounted and Suspended Luminaires LED Luminaires complete with all accessories such as driver etc. and necessary connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department CE. Apprv. Philips 24 W, Astra Surface & wall mounted LED batten Model BN150W LED20S-6500 PSE OD GR or equivalent as approved by the Deptt.
164Supplying,installation,testing and Commission of the following LED lamp as directed by the department CE ApprvPhilips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt.
165Supplying,installation,testing and Commission of the following indoor Recessed Mounted LED Luminaires complete with all accessories such as driver etc. In the flase ceiling type Armstronng /Gypsum or similar ceiling mouting with necessary support and connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department CE Apprv. Philips lighting luminaire 15 W GreenLED Model BBS170 1xDLED -5000 PSU WH/ BBS170 1xDLED -4000 PSU WH or GreenLED Square ModelBBS175 1xDLED -5000 PSU WH/ BBS175 1xDLED -4000 PSU WH or equivalent as approved by the Deptt.
166Supplying with fitting and fixing of Foot lamp with Box and lamp holder in 3 module recessed system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. Without lamp.
167Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)in surface/ recessedsystem complete as per direction of department. 3 module
1686 module
16912 module
170Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)front plate of suitable colour as per direction of department. 3 module
1716 module
17212 module
173Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
174Supplying and fixing of polished Brass Bracket of 18 S.W.G,25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
175CE Apprv. Supplying, installation, testing and Commission of the following indoor Decorative Recess mountedLEDdown lighter luminaries of model no-LESP01R009XC / LESP01R009XN /LESP01R009XW / L00957R000 / L00940R000 /L00930R000/LD90-111 - XXX-65-XXcomplete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar/ LT / Wipro make).
176Supplying and fixing of Jaquar or equivalent Philips/ Wipro LED wall light fittings complete with Shade, back plate including connection cable,as approved by the Deptt.s etc. as required. Linear LED Tube 12W
177Supplying with fitting and fixing of Foot lamp with Box and lamp holder in 3 module recessed system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. Without lamp.
178CE Apprv Supplying fitting & fixing of LED Bulb non-dimmable in the existing batten / angle holderas required and as directed by the department ( Jaquar or eqvt. make). 6/b Prima Series Bulb 7W
179CEAppr.Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. 10/b BN 021C LED 20 S PSU CW GR S2
180CE Apprv. Supplying fitting & fixing of LED Kubik Batten tube light fitting 300mm lengthas required and as directed by the department ( Jaquar or eqvt. make). 7/c kubik Series Batten tube fitting 20W
181Supplying and fixing of Jaquar or equivalent Philips/ Wipro LED wall light fittings complete with Shade, back plate including connection cable,as approved by the Deptt.s etc. as required. 3.23.3 LED Bulk Head 8W
182CE Apprv Supplying,installation,testing and commissioning of the following integral flood lighting luminaires conforming to IP 65 / IP 66 suitable for vertical and horizontal mounting applications pressure die cast powder coated aluminium alloy housing with corrosion resistance powder coating using nano Technology transparent injection moulded poly carbonate UV stabilized diffuser having high impact strength to withstand min IK09 with high power LED and unique flood optics to ensure uniform light distribution and maintenance free system ideal for area lighting, high mast lighting, sports lighting and billboard. The luminaires should be equiped with external surge protection device to withstand 10 KV / 5KV including connection with 2.5 sqmm 3 core PVC insulated round copper conductor as required and as directed by the department. 12/g BVP 410 LED 215 CW HE NB FG S4 XTFCL
183Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
184Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
185Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
186Supplying including fitting fixing of followingstar rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable,as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) ECBC1.1.1Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
18726/SB8.21 Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 8.21.2 120 watt electronic modular 5 step speed control2 - module
188Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Power Flow225 mm sweep (ORIENTmake)
189Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake) 12 way SPN double door
190Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake) 4way TPN (4+12)double door
191Supplying including fitting fixing of followingA.C. Wall fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. ORIENTmake or equivalent Ushamake Air Circulator wall fan 600 mm sweep Turbo force
192Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 100 watt electronic modular 4 step speed control2 - module type
193Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split typeair conditioner of the following capacity with cordless remote complete withindoor and outdoor unit, copper pipeand electrical connection as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department. 2 Ton capacity Voltage make
194Supplying with fitting and fixingVoltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUSmake) 5.0 KVA Automatic Input 90-280 V Out put 200-240 V
195Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. Overload Relay Range 16 - 25 Amps in 3 Module
196Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.ABB, Schneider MG, legrand, Hagermake) 8 way SPN double door
197Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake) 6way TPN (4+18)double door
198Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 1C Series 6 - 32 A
199Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake) 6-32A
200Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DPRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hagermake) 40A
201Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4PRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hagermake)
202Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4PRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity 4P RCCB 6-32A
2036-32A
204Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DPRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 30mA sensitivity DP RCCB 40A 6-32A
205Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, neutral adjustable with earth fault protection Without enclosureof the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 50KA(ABB, Schneider, legrand, L&T, Siemens, C&Smake) 160A
206Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.35M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and35mm X 35mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 6nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 20mm X 3mm4 strip copper Bus-Bar 0.6 M length each Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no Digital 3 Phase Ammeter Accuracy class 0.5- 1 no Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no Voltmeter & Ammeter Selector Switch- 2 no 2 A Slide fuse unit - 3nos (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
207Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.50M X 1.60MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and40mm X 40mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 400A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 40mm X 5mm 4 strip copper Bus - Bar 1.50 M length each Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no Digital 3 Phase Ammeter Accuracy class 0.5- 1 no Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no Voltmeter & Ammeter Selector Switch- 2 no 2 A Slide fuse unit - 3nos (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
208Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DPRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 3P MCCB (Havells, HPL, Indo Asian make) 63A
209125A
210Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch,through medium duty G.I. pipe(Tata/ Nezonemake or equivalent as approved by the Deptt)bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make): 3&1/2core A2XFY 70.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
211150.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
212Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch,through medium duty G.I. pipe(Tata/ Nezonemake or equivalent as approved by the Deptt)bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 150.00 Sq.mm 3&1/2 Core U.G. cable in65mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
213Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch,through medium duty G.I. pipe(Tata/ Nezonemake or equivalent as approved by the Deptt)bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 3&1/2core A2XWFY,A2XFY 70.00 Sq.mm 3&1/2 Core U.G. cable in65mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy