}

Tender For Renovation And Installation Of Play Equipments In Bastra Uddyan At Sualkuchi, Saraighat War Memorial Park At Agyathuri, Children Park At Majgaon And Silsako, North Guwahati, guwahati-Assam

Guwahati Metropolitan Development Authority-GMDA has published Tender For Renovation And Installation Of Play Equipments In Bastra Uddyan At Sualkuchi, Saraighat War Memorial Park At Agyathuri, Children Park At Majgaon And Silsako, North Guwahati. Submission Date for this Tender is 24-01-2024. Sport Accessories Tenders in guwahati Assam. Bidders can get complete Tender details and download the document.




Tender Notice

41428110
Tender For Renovation And Installation Of Play Equipments In Bastra Uddyan At Sualkuchi, Saraighat War Memorial Park At Agyathuri, Children Park At Majgaon And Silsako, North Guwahati
Open Tender
Indian
Assam
guwahati
24-01-2024

Tender Details

Renovation And Installation Of Play Equipments In Bastra Uddyan At Sualkuchi, Saraighat War Memorial Park At Agyathuri, Children Park At Majgaon And Silsako, North Guwahati-Bastra Udyan, Sualkuchi 2 Earth Workearth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In- Charge.All Kinds Of Soil. 3 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 4 Plinth Filling: Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 5 Concrete Works:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 6 Reinforced Cement Concrete Worksproviding And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . 7 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement:1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 8 Formworkcentering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 9 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Suspended Floors, Roofs, Landings, Balconies And Access Platform 10 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 11 Steel Reinforcementsteel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 12 Masonry Work: Brick Work With Common Burnt Clay F.P.S. ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In::: Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 13 Masonry Work : Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. : Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand ) 14 Cement Plastering12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 15 Applying Priming Coat:With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 16 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 17 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 18 Vitrified Floor Tilesproviding And Laying Vitrified Tiles In Floor With Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tile 600X600 Mm 19 Wpc Door Frameproviding And Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door / Window / Celestory Windows & Other Frames / Chowkhat Comprising Of Virgin Pvc Polymer Of K Value 58- 60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg / Cum, Screw Withdrawal Strength Of 2200 N ( Face ) & 1100 N ( Edge ) , Minimum Compressive Strength Of 58 N / Mm2, Modulus Of Elasticity 900 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With M.S Hold Fast / Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge. ( M.S Hold Fast / Lugs Or Ss Dash Fasteners Shall Be Paid For Separately ) . Note: For Wpc Solid Door / Window Frames, Minus 5Mm Tolerance In Dimensions I.E Depth And Width Of Profile Shall Be Acceptable. Variation In Profile Dimensions On Plus Side Shall Be Acceptable But No Extra Payment On This Account Shall Be Made.Frame Size 65 X 150 Mm 20 Door Shutter: Providing And Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of Required Size Comprising Of Virgin Polymer Of K Value 58-60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg / Cum And Screw Withdrawal Strength Of 1800 N ( Face ) & 900 N ( Edge ) , Minimum Compressive Strength 50 N / Mm2, Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk S.S Screws, All As Per Direction Of Engineer-In- Charge. ( Note: Stainless Steel Butt Hinges And Necessary S.S Screws Shall Be Paid Separately ) 35 Mm Thick 21 Upvc Window : Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Window Upto 1.50 M In Height Dimension Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Extruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy ( White Powder Coated ) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers ( Weight Bearing Capacity To Be 40 Kg ) , G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes, Wire Mesh And Silicon Sealent Shall Be Paid Separately ) . Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Note: For Upvc Frame And Sash Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable.::Two Track Two Panels Sliding Window Made Of ( Small Series ) Frame 52 X 44 Mm &Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. ( Area Of Window Upto 1.75 Sqm ) 22 M.S. Grill: Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc. 23 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall15 Mm Nominal Outer Dia Pipes 24 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall20 Mm Nominal Outer Dia Pipes 25 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall25 Mm Nominal Outer Dia Pipes 26 Soak Pitmaking Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 27 Urinal Basin:Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :One Urinal Basin With Brass. Push Plate. ( Jaquar And Cera Or Eqv. Brand Make ) 28 Counter Top Wash Basin: Providing Vitreous Chinawash Basinwith Ci / Ms Brackets, C.P Brass Chain With Plug, Pvc Waste Pipe Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls / Platform Wherever Required. ( Pillar Cock, Stop Cocks, Waste Coupling Are To Be Paid Separately ) ( Jaquar And Cera Or Eqv. Brand Make ) 29 Wc: Providing Vitreous Chinawall Hung Wcwith Conceal Cistern, Ci / Ms Brackets, C.P Brass Chain With Plug, Pvc Waste Pipe Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls / Platform Wherever Required. Make : Jaquar, Cera , Hindware Or Eqv. Brand 30 Pillar Cocksupplying Fitting And Fixing Pillar Cock 15Mm Dia Complete As Directed And Specified As Follows. ( Pipes Will Be Measured And Paid Separately ) . ( Jaquar And Cera Or Eqv. Brand Make ) 31 Health Faucetsupplying Fitting And Fixing Hand Shower ( Health Faucet ) Abs With Rubbit Cleaning System, 1.25 M Long Pvc Flexible Tube With Abs Wall Hook And Operating Knob Complete In All Respects. Hindware ( Cat No. F160013 ) ( Jaquar And Cera Or Eqv. Brand Make ) 32 Floor Trap Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors 100 Mm Inlet And 75 Mm Outlet: Silver With Crome Finish Solid Construction Fast Drainage And Automatic Sealing. 33 Providing And Fixing Of Urinal Basin Partition ( Jaquar And Cera Or Eqv. Brand Make ) 34 Providing And Fixing Of Angle Cock Complete As Directed And Specified. ( Jaquar And Cera Or Eqv. Brand Make ) 35 Supplying, Fitting And Fixing Pvc Pipes Of 6 Kg / Cm2 ( Supreme / Prince ) Or Other Isiapproved Including Joining, Fitting And Fixing Wiyh Clamps Etc.As Necessary Completeat All Levels Including Below G.L As Directed And Specified.A ) In Exposed Surfaces Or In Trenches. ( I ) 110Mm Dia. 36 Supplying, Installing, Testing And Commissioning Of Double Arm Pole 4 Mtr Height ( M.S Pole Painted ) Light Fixture 50 Watt Medium 37 Supply And Installation Of Net Climber 38 Supply And Installation Ofmulty Play Station. 39 Supply And Installation Of All Purpose Dustbin 40 Repair Renovation Of Garden Statue And Water Body 41 Supply Fitting And Installation Of Garden Bench With Back Rest. 42 Supply Installation And Repairing And Artistic Paiting Of Meusium Statue / Artistic Wok 43 Supply Installation And Repairing Of Garden Entarnce Gate / Artistic Work. 44 Saraighat War Memorial Park, Agyathuri 45 Earth Workearth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In- Charge.All Kinds Of Soil. 46 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 47 Plinth Filling: Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 48 Concrete Works:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 49 Reinforced Cement Concrete Worksproviding And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 50 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement:1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 51 Formworkcentering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 52 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Suspended Floors, Roofs, Landings, Balconies And Access Platform 53 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 54 Steel Reinforcementsteel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 55 Masonry Work: Brick Work With Common Burnt Clay F.P.S. ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In::: Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 56 Masonry Work : Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. : Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand ) 57 Cement Plastering12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 58 Applying Priming Coat:With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 59 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 60 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 61 Vitrified Floor Tilesproviding And Laying Vitrified Tiles In Floor With Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tile 600X600 Mm 62 Wpc Door Frameproviding And Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door / Window / Celestory Windows & Other Frames / Chowkhat Comprising Of Virgin Pvc Polymer Of K Value 58- 60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg / Cum, Screw Withdrawal Strength Of 2200 N ( Face ) & 1100 N ( Edge ) , Minimum Compressive Strength Of 58 N / Mm2, Modulus Of Elasticity 900 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With M.S Hold Fast / Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge. ( M.S Hold Fast / Lugs Or Ss Dash Fasteners Shall Be Paid For Separately ) . Note: For Wpc Solid Door / Window Frames, Minus 5Mm Tolerance In Dimensions I.E Depth And Width Of Profile Shall Be Acceptable. Variation In Profile Dimensions On Plus Side Shall Be Acceptable But No Extra Payment On This Account Shall Be Made.Frame Size 65 X 150 Mm 63 Door Shutter: Providing And Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of Required Size Comprising Of Virgin Polymer Of K Value 58-60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg / Cum And Screw Withdrawal Strength Of 1800 N ( Face ) & 900 N ( Edge ) , Minimum Compressive Strength 50 N / Mm2, Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk S.S Screws, All As Per Direction Of Engineer-In- Charge. ( Note: Stainless Steel Butt Hinges And Necessary S.S Screws Shall Be Paid Separately ) 35 Mm Thick 64 Upvc Window : Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Window Upto 1.50 M In Height Dimension Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Extruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy ( White Powder Coated ) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers ( Weight Bearing Capacity To Be 40 Kg ) , G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes, Wire Mesh And Silicon Sealent Shall Be Paid Separately ) . Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Note: For Upvc Frame And Sash Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable.::Two Track Two Panels Sliding Window Made Of ( Small Series ) Frame 52 X 44 Mm &Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. ( Area Of Window Upto 1.75 Sqm ) 65 Antiskid Tilesproviding And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Antiskid Finish Of Sizesize Of Tile 300X 300 Mm 66 Precast Rcc Rectangular Coversproviding And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Rcc Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Rcc Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C / C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I / C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. 67 Flooringcement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 68 Cement Concrete Tiles: Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) . 11.20.3 Dark Shade Pigment Using Ordinary Cement ( 300X300 ) Mmparking Tiles ) 69 M.S. Grill: Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc. 70 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall15 Mm Nominal Outer Dia Pipes 71 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall20 Mm Nominal Outer Dia Pipes 72 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall25 Mm Nominal Outer Dia Pipes 73 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete25 Mm Nominal Bore 74 Soak Pitmaking Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 75 Urinal Basin:Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :One Urinal Basin With Brass. Push Plate. ( Jaquar And Cera Or Eqv. Brand Make ) 76 Counter Top Wash Basin: Providing Vitreous Chinawash Basinwith Ci / Ms Brackets, C.P Brass Chain With Plug, Pvc Waste Pipe Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls / Platform Wherever Required. ( Pillar Cock, Stop Cocks, Waste Coupling Are To Be Paid Separately ) ( Jaquar And Cera Or Eqv. Brand Make ) 77 Wc: Providing Vitreous Chinawall Hung Wcwith Conceal Cistern, Ci / Ms Brackets, C.P Brass Chain With Plug, Pvc Waste Pipe Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls / Platform Wherever Required. Make : Jaquar, Cera , Hindware Or Eqv. Brand 78 Pillar Cocksupplying Fitting And Fixing Pillar Cock 15Mm Dia Complete As Directed And Specified As Follows. ( Pipes Will Be Measured And Paid Separately ) . ( Jaquar And Cera Or Eqv. Brand Make ) 79 Health Faucetsupplying Fitting And Fixing Hand Shower ( Health Faucet ) Abs With Rubbit Cleaning System, 1.25 M Long Pvc Flexible Tube With Abs Wall Hook And Operating Knob Complete In All Respects. Hindware ( Cat No. F160013 ) ( Jaquar And Cera Or Eqv. Brand Make ) 80 Floor Trap Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors 100 Mm Inlet And 75 Mm Outlet: Silver With Crome Finish Solid Construction Fast Drainage And Automatic Sealing. 81 Providing And Fixing Of Urinal Basin Partition ( Jaquar And Cera Or Eqv. Brand Make ) 82 Providing And Fixing Of Angle Cock Complete As Directed And Specified. ( Jaquar And Cera Or Eqv. Brand Make ) 83 Over Head Pvc Water Tank:Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is:12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 84 Supplying, Fitting And Fixing Pvc Pipes Of 6 Kg / Cm2 ( Supreme / Prince ) Or Other Isiapproved Including Joining, Fitting And Fixing Wiyh Clamps Etc.As Necessary Completeat All Levels Including Below G.L As Directed And Specified.A ) In Exposed Surfaces Or In Trenches. ( I ) 110Mm Dia. 85 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group B 86 Underground Cablelaying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required.Up To35 Sq. Mm 87 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 430 Volts, 10 KaC Series, Miniature Circuit Breaker Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole And Neutral 16A 88 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 89 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivitycurrent 30Ma Intheexisting Mcbdb Complete With Connections, Testing And Commissioning Etc. As Required For Rooms And Media Room.40A 90 Earthing Withg.I.Earthpipe4.5Metrelong, 40Mmdia Cover Plate Having Locking Arangement And Watereing Pipe With Charcoal / Coke Andsalt As Requiredfor Out Doorlighting System& Indoor Dbs. One For Vtpn And 1 Forwashr Room And1 For Cofee House . 91 Supplying And Drawingfollowingsize Of Frls Pvc Insuleted Copper Conductor, Single Core Cable In Thr Existing Surface / Recessed Steel / Pvc Conduit As Required1.17. 1X17.20 2X4 Sq.Mm 92 Supply Of Ip65, 60W Led Cdldecorative Street Light For Beautification Application. Make: Empire ( Ref. Cat.No. Lptc 40 Cdl ) Of Cgl / Vega Of Surya Or Equivalent Syska, Havells, Philips, Jaquar, K / Lights As Approved. 93 Bollard Light 94 Supply Of 6 Mtrs Heightdecorative Polewith Inbuilddecorativesinglearmmatching With The Lamps Set As Described Above. Please Refer Cgl Decorative Pole Cataloguefor Cgl Set Or For Surya Makeset Please Refer Corwndecorative Pole Oras Approved For Other Company Make Decorative Set. 95 Children Park Majgaon, North Guwahati 96 Earth Workearth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In- Charge.All Kinds Of Soil. 97 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 98 Plinth Filling: Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 99 Concrete Works:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 100 Reinforced Cement Concrete Worksproviding And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 101 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement:1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 102 Formworkcentering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 103 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Suspended Floors, Roofs, Landings, Balconies And Access Platform 104 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 105 Steel Reinforcementsteel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 106 Masonry Work: Brick Work With Common Burnt Clay F.P.S. ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In::: Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 107 Masonry Work : Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. : Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand ) 108 Cement Plastering12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 109 Applying Priming Coat:With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 110 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 111 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 112 Vitrified Floor Tilesproviding And Laying Vitrified Tiles In Floor With Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tile 300X300 Mm 113 Wpc Door Frameproviding And Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door / Window / Celestory Windows & Other Frames / Chowkhat Comprising Of Virgin Pvc Polymer Of K Value 58- 60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg / Cum, Screw Withdrawal Strength Of 2200 N ( Face ) & 1100 N ( Edge ) , Minimum Compressive Strength Of 58 N / Mm2, Modulus Of Elasticity 900 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With M.S Hold Fast / Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge. ( M.S Hold Fast / Lugs Or Ss Dash Fasteners Shall Be Paid For Separately ) . Note: For Wpc Solid Door / Window Frames, Minus 5Mm Tolerance In Dimensions I.E Depth And Width Of Profile Shall Be Acceptable. Variation In Profile Dimensions On Plus Side Shall Be Acceptable But No Extra Payment On This Account Shall Be Made.Frame Size 65 X 150 Mm 114 Door Shutter: Providing And Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of Required Size Comprising Of Virgin Polymer Of K Value 58-60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg / Cum And Screw Withdrawal Strength Of 1800 N ( Face ) & 900 N ( Edge ) , Minimum Compressive Strength 50 N / Mm2, Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk S.S Screws, All As Per Direction Of Engineer-In- Charge. ( Note: Stainless Steel Butt Hinges And Necessary S.S Screws Shall Be Paid Separately ) 35 Mm Thick 115 Upvc Window : Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Window Upto 1.50 M In Height Dimension Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Extruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy ( White Powder Coated ) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers ( Weight Bearing Capacity To Be 40 Kg ) , G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes, Wire Mesh And Silicon Sealent Shall Be Paid Separately ) . Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Note: For Upvc Frame And Sash Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable.::Two Track Two Panels Sliding Window Made Of ( Small Series ) Frame 52 X 44 Mm &Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. ( Area Of Window Upto 1.75 Sqm ) 116 Antiskid Tilesproviding And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Antiskid Finish Of Sizesize Of Tile 300X 300 Mm 117 Precast Rcc Rectangular Coversproviding And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Rcc Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Rcc Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C / C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I / C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. 118 M.S. Grill: Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc. 119 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall15 Mm Nominal Outer Dia Pipes 120 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall20 Mm Nominal Outer Dia Pipes 121 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall25 Mm Nominal Outer Dia Pipes 122 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete25 Mm Nominal Bore 123 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is:12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 124 Supplying, Fitting And Fixing Pvc Pipes Of 6 Kg / Cm2 ( Supreme / Prince ) Or Other Isiapproved Including Joining, Fitting And Fixing Wiyh Clamps Etc.As Necessary Completeat All Levels Including Below G.L As Directed And Specified.A ) In Exposed Surfaces Or In Trenches. ( I ) 110Mm Dia. 125 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group B 126 Underground Cablelaying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required.Up To35 Sq. Mm 127 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 430 Volts, 10 KaC Series, Miniature Circuit Breaker Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole And Neutral 16A 128 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 129 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivitycurrent 30Ma Intheexisting Mcbdb Complete With Connections, Testing And Commissioning Etc. As Required For Rooms And Media Room.40A 130 Earthing Withg.I.Earthpipe4.5Metrelong, 40Mmdia Cover Plate Having Locking Arangement And Watereing Pipe With Charcoal / Coke Andsalt As Requiredfor Out Doorlighting System& Indoor Dbs. One For Vtpn And 1 Forwashr Room And1 For Cofee House . 131 Supplying And Drawingfollowingsize Of Frls Pvc Insuleted Copper Conductor, Single Core Cable In Thr Existing Surface / Recessed Steel / Pvc Conduit As Required1.17. 1X17.20 2X4 Sq.Mm 132 Supply Of Ip65, 60W Led Cdldecorative Street Light For Beautification Application. Make: Empire ( Ref. Cat.No. Lptc 40 Cdl ) Of Cgl / Vega Of Surya Or Equivalent Syska, Havells, Philips, Jaquar, K / Lightas Approved. 133 Supply Installation Of Bollard Light 134 Supply Of 6 Mtrs Heightdecorative Polewith Inbuilddecorativesinglearmmatching With The Lamps Set As Described Above. Please Refer Cgl Decorative Pole Cataloguefor Cgl Set Or For Surya Makeset Please Refer Corwndecorative Pole Oras Approved For Other Company Make Decorative Set. 135 Supply And Installation Of Net Climber 136 Supply And Installation Of Four Seatter See-Saw 137 Supply And Installation Of Merry Go Round 138 Supply And Installation Of Cycling 139 Supply And Installation Of Air Walker 140 Supply And Installation Of Waist Twister 141 Supply Fitting And Installation Of Garden Bench With Back Rest. ( As Per Quotation ) 142 Machine Boring Of Deep Tube Well Upto 150Mm Dia. Bore Hole Asdirected By The Engineer In Charge 143 Supply Installation Testing And Commissioning Of Centrifugal Pump ( Submersible / Vertical / Horizontal Pump ) Of Flow Rate 220 Lpm @ 50M Head ( One Working And One Standby ) 144 Supply Fitting And Installation Of Two In One Swing 145 Supply Fitting And Installation Of Rowing Machine 146 Silsako Park, North Guwahati 147 Earth Workearth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In- Charge.All Kinds Of Soil. 148 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 149 Plinth Filling: Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 150 Concrete Works:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 151 Reinforced Cement Concrete Worksproviding And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 152 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement:1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 153 Formworkcentering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 154 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Suspended Floors, Roofs, Landings, Balconies And Access Platform 155 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 156 Steel Reinforcementsteel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 157 Masonry Work: Brick Work With Common Burnt Clay F.P.S. ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In::: Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 158 Masonry Work : Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. : Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand ) 159 Cement Plastering12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 160 Applying Priming Coat:With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 161 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 162 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 163 Vitrified Floor Tilesproviding And Laying Vitrified Tiles In Floor With Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tile 300X300 Mm 164 Wpc Door Frameproviding And Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door / Window / Celestory Windows & Other Frames / Chowkhat Comprising Of Virgin Pvc Polymer Of K Value 58- 60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg / Cum, Screw Withdrawal Strength Of 2200 N ( Face ) & 1100 N ( Edge ) , Minimum Compressive Strength Of 58 N / Mm2, Modulus Of Elasticity 900 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With M.S Hold Fast / Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge. ( M.S Hold Fast / Lugs Or Ss Dash Fasteners Shall Be Paid For Separately ) . Note: For Wpc Solid Door / Window Frames, Minus 5Mm Tolerance In Dimensions I.E Depth And Width Of Profile Shall Be Acceptable. Variation In Profile Dimensions On Plus Side Shall Be Acceptable But No Extra Payment On This Account Shall Be Made.Frame Size 65 X 150 Mm 165 Door Shutter: Providing And Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of Required Size Comprising Of Virgin Polymer Of K Value 58-60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg / Cum And Screw Withdrawal Strength Of 1800 N ( Face ) & 900 N ( Edge ) , Minimum Compressive Strength 50 N / Mm2, Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardant And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk S.S Screws, All As Per Direction Of Engineer-In- Charge. ( Note: Stainless Steel Butt Hinges And Necessary S.S Screws Shall Be Paid Separately ) 35 Mm Thick 166 Upvc Window : Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Window Upto 1.50 M In Height Dimension Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Extruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy ( White Powder Coated ) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers ( Weight Bearing Capacity To Be 40 Kg ) , G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes, Wire Mesh And Silicon Sealent Shall Be Paid Separately ) . Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Note: For Upvc Frame And Sash Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable.::Two Track Two Panels Sliding Window Made Of ( Small Series ) Frame 52 X 44 Mm &Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. ( Area Of Window Upto 1.75 Sqm ) 167 Antiskid Tilesproviding And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Antiskid Finish Of Sizesize Of Tile 300X 300 Mm 168 Precast Rcc Rectangular Coversproviding And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Rcc Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Rcc Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C / C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I / C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. 169 Pcgi Roofingproviding And Fixing Precoated Galvanised Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0.50 Mm ( + 0.05 % ) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X55 Mm ) With Epdm Seal, Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 170 Applying Priming Coat: ( Truss ) With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works. 171 Flooring ( Stage ) Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 172 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work ( Truss ) 173 M.S. Grill: Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc. 174 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall15 Mm Nominal Outer Dia Pipes 175 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall20 Mm Nominal Outer Dia Pipes 176 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.Internal Work - Exposed On Wall25 Mm Nominal Outer Dia Pipes 177 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete25 Mm Nominal Bore 178 Soak Pitmaking Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 179 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is:12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 180 Supplying, Fitting And Fixing Pvc Pipes Of 6 Kg / Cm2 ( Supreme / Prince ) Or Other Isiapproved Including Joining, Fitting And Fixing Wiyh Clamps Etc.As Necessary Completeat All Levels Including Below G.L As Directed And Specified.A ) In Exposed Surfaces Or In Trenches. ( I ) 110Mm Dia. 181 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group B 182 Underground Cablelaying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required.Up To35 Sq. Mm 183 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 430 Volts, 10 KaC Series, Miniature Circuit Breaker Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole And Neutral 16A 184 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 185 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivitycurrent 30Ma Intheexisting Mcbdb Complete With Connections, Testing And Commissioning Etc. As Required For Rooms And Media Room.40A 186 Earthing Withg.I.Earthpipe4.5Metrelong, 40Mmdia Cover Plate Having Locking Arangement And Watereing Pipe With Charcoal / Coke Andsalt As Requiredfor Out Doorlighting System& Indoor Dbs. One For Vtpn And 1 Forwashr Room And1 For Cofee House . 187 Supplying And Drawingfollowingsize Of Frls Pvc Insuleted Copper Conductor, Single Core Cable In Thr Existing Surface / Recessed Steel / Pvc Conduit As Required1.17. 1X17.20 2X4 Sq.Mm 188 Supply Of Ip65, 60W Led Cdldecorative Street Light For Beautification Application. Make: Empire ( Ref. Cat.No. Lptc 40 Cdl ) Of Cgl / Vega Of Surya Or Equivalent Syska, Havells, Philips, Jaquar, K / Lightas Approved. 189 Supply Installation Of Bollard Light 190 Supply Of 6 Mtrs Heightdecorative Polewith Inbuilddecorativesinglearmmatching With The Lamps Set As Described Above. Please Refer Cgl Decorative Pole Cataloguefor Cgl Set Or For Surya Makeset Please Refer Corwndecorative Pole Oras Approved For Other Company Make Decorative Set. 191 Supply And Installation Of Net Climber 192 Supply And Installation Of Double Bar See-Saw 193 Supply And Installation Of Tubo Roto Slide 194 Supply And Installation Of Arc Swing Rubber Belt 195 Supply And Installation Of Multiplay Station 196 Supply And Installation Of Leg Press 197 Supply And Installation Of Cycling 198 Supply And Installation Of Wsist Twister 199 Supply And Installation Of Two Level Chin Up 200 Supply And Installation Of All Purpose Dustbin 201 Push And Pull Chair 202 Supply Fitting And Installation Of Garden Bench With Back Rest. ( As Per Quotation ) 203 Machine Boring Of Deep Tube Well Upto 150Mm Dia. Bore Hole Asdirected By The Engineer In Charge 204 Supply Installation Testing And Commissioning Of Centrifugal Pump ( Submersible / Vertical / Horizontal Pump ) Of Flow Rate 220 Lpm @ 50M Head ( One Working And One Standby ) 205 Repairing Of Artistic Work: Entry Gate And Statue Of Garden 206 Supply And Installation Of Fountain. 207 Supply And Installation Of Bust

Key Value

Document Fees
INR 2000 /-
EMD
INR 255400.0 /-
Tender Value
INR 1.27 Crore /-

BOQ Items

Name of Work: Renovation & Installation of play equipments in Bastra Uddyan at Sualkuchi, Saraighat War memorial Park at Agyathuri, Children Park at Majgaon & Silsako, North Guwahati
Sl. No. Item Description
1Bastra Udyan, Sualkuchi
2EARTH WORK Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge. All kinds of soil.
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
4PLINTH FILLING: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
5CONCRETE WORKS: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
6REINFORCED CEMENT CONCRETE WORKS Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
7Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
8FORMWORK Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
9Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
10Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
11STEEL REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
12MASONRY WORK: Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in::: Cement mortar 1:4 (1 cement : 4 coarse sand)
13MASONRY WORK : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : Cement mortar 1:3 (1 cement :3 coarse sand)
14CEMENT PLASTERING 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
15Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
16Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
17Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
18VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
19WPC DOOR FRAME Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Celestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 150 mm
20DOOR SHUTTER: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick
21UPVC WINDOW : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.::Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
22M.S. GRILL: Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
23Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes
24Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes
25Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes
26SOAK PIT Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
27URINAL BASIN: Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with Brass. push plate.(Jaquar and Cera or eqv. brand make)
28COUNTER TOP WASH BASIN: Providing vitreous Chinawash basinwith CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls/ platform wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) (Jaquar and Cera or eqv. brand make)
29WC: Providing vitreous ChinaWall Hung WCwith Conceal Cistern, CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls/ platform wherever required. Make : Jaquar, Cera , Hindware or eqv. Brand
30PILLAR COCK Supplying fitting and fixing pillar cock 15mm dia complete as directed and specified as follows. (pipes will be measured and paid separately). (Jaquar and Cera or eqv. brand make)
31HEALTH FAUCET Supplying fitting and fixing hand shower (health faucet) ABS with rubbit cleaning system, 1.25 m long PVC flexible tube with ABS wall hook and operating knob complete in all respects. Hindware(Cat No. F160013) (Jaquar and Cera or eqv. brand make)
32FLOOR TRAP Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 75 mm outlet: Silver with crome finish solid construction fast drainage and automatic sealing.
33Providing and fixing of URINAL BASIN partition (Jaquar and Cera or eqv. brand make)
34Providing and fixing of Angle cock complete as directed and specified. (Jaquar and Cera or eqv. brand make)
35Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining, fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
36Supplying, installing, testing and commissioning of Double Arm Pole 4 MTR Height (M.S POLE Painted) Light Fixture 50 Watt Medium
37Supply and installation of Net Climber
38Supply and installation ofMulty Play Station.
39Supply and installation of All Purpose Dustbin
40Repair Renovation of Garden Statue and water Body
41Supply fitting and installation of Garden Bench with back rest.
42Supply installation and repairing and artistic paiting of Meusium statue / Artistic wok
43Supply installation and repairing of garden Entarnce gate /Artistic work.
44Saraighat War Memorial Park, Agyathuri
45EARTH WORK Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge. All kinds of soil.
46Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
47PLINTH FILLING: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
48CONCRETE WORKS: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
49REINFORCED CEMENT CONCRETE WORKS Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
50Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
51FORMWORK Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
52Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
53Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
54STEEL REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
55MASONRY WORK: Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in::: Cement mortar 1:4 (1 cement : 4 coarse sand)
56MASONRY WORK : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : Cement mortar 1:3 (1 cement :3 coarse sand)
57CEMENT PLASTERING 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
58Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
59Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
60Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
61VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
62WPC DOOR FRAME Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Celestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 150 mm
63DOOR SHUTTER: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick
64UPVC WINDOW : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.::Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
65ANTISKID TILES Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Antiskid finish of size Size of Tile 300x 300 mm
66Precast RCC Rectangular Covers Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
67Flooring Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
68cement concrete tiles: Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 11.20.3 Dark shade pigment using ordinary cement (300X300 ) mmparking tiles)
69M.S. GRILL: Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
70Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes
71Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes
72Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes
73Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete25 mm nominal bore
74SOAK PIT Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
75URINAL BASIN: Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with Brass. push plate.(Jaquar and Cera or eqv. brand make)
76COUNTER TOP WASH BASIN: Providing vitreous Chinawash basinwith CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls/ platform wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) (Jaquar and Cera or eqv. brand make)
77WC: Providing vitreous ChinaWall Hung WCwith Conceal Cistern, CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls/ platform wherever required. Make : Jaquar, Cera , Hindware or eqv. Brand
78PILLAR COCK Supplying fitting and fixing pillar cock 15mm dia complete as directed and specified as follows. (pipes will be measured and paid separately). (Jaquar and Cera or eqv. brand make)
79HEALTH FAUCET Supplying fitting and fixing hand shower (health faucet) ABS with rubbit cleaning system, 1.25 m long PVC flexible tube with ABS wall hook and operating knob complete in all respects. Hindware(Cat No. F160013) (Jaquar and Cera or eqv. brand make)
80FLOOR TRAP Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 75 mm outlet: Silver with crome finish solid construction fast drainage and automatic sealing.
81Providing and fixing of URINAL BASIN partition (Jaquar and Cera or eqv. brand make)
82Providing and fixing of Angle cock complete as directed and specified. (Jaquar and Cera or eqv. brand make)
83Over head PVC Water Tank:Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
84Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining, fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
85Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
86UNDERGROUND CABLE Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to35 sq. mm
87Supplying and fixing 5 amps to 32 amps rating, 240 / 430 volts, 10 KA"C" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 16A
88Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
89Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivitycurrent 30mA intheexisting MCBDB complete with connections, testing and commissioning etc. as required for rooms and media room. 40A
90Earthing withG.I.earthpipe4.5metrelong,40mmdia cover plate having locking arangement and watereing pipe with charcoal / coke andsalt as requiredfor out doorlighting system& indoor DBs. One for VTPN and 1 forwashr room and1 for cofee house .
91Supplying and drawingfollowingsize of FRLS PVC insuleted copper conductor, single core cable in thr existing surface/recessed steel/PVC conduit as required1.17. 1x17.20 2x4 sq.mm
92Supply of IP65, 60W LED CDLdecorative street light for beautification application. Make: Empire ( Ref. Cat.No. LPTC 40 CDL) of CGL/ Vega of Surya or equivalent Syska, Havells, Philips,Jaquar, K/lights as approved.
93Bollard Light
94Supply of 6 mtrs heightdecorative polewith inbuilddecorativeSINGLEarmmatching with the lamps set as described above. Please refer CGL decorative pole cataloguefor CGL set or for Surya makeset please refer corwndecorative pole oras approved for other company make decorative set.
95Children Park Majgaon, North Guwahati
96EARTH WORK Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge. All kinds of soil.
97Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
98PLINTH FILLING: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
99CONCRETE WORKS: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
100REINFORCED CEMENT CONCRETE WORKS Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
101Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
102FORMWORK Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
103Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
104Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
105STEEL REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
106MASONRY WORK: Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in::: Cement mortar 1:4 (1 cement : 4 coarse sand)
107MASONRY WORK : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : Cement mortar 1:3 (1 cement :3 coarse sand)
108CEMENT PLASTERING 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
109Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
110Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
111Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
112VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 300x300 mm
113WPC DOOR FRAME Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Celestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 150 mm
114DOOR SHUTTER: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick
115UPVC WINDOW : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.::Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
116ANTISKID TILES Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Antiskid finish of size Size of Tile 300x 300 mm
117Precast RCC Rectangular Covers Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
118M.S. GRILL: Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
119Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes
120Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes
121Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes
122Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete25 mm nominal bore
123Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
124Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining, fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
125Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
126UNDERGROUND CABLE Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to35 sq. mm
127Supplying and fixing 5 amps to 32 amps rating, 240 / 430 volts, 10 KA"C" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 16A
128Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
129Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivitycurrent 30mA intheexisting MCBDB complete with connections, testing and commissioning etc. as required for rooms and media room. 40A
130Earthing withG.I.earthpipe4.5metrelong,40mmdia cover plate having locking arangement and watereing pipe with charcoal / coke andsalt as requiredfor out doorlighting system& indoor DBs. One for VTPN and 1 forwashr room and1 for cofee house .
131Supplying and drawingfollowingsize of FRLS PVC insuleted copper conductor, single core cable in thr existing surface/recessed steel/PVC conduit as required1.17. 1x17.20 2x4 sq.mm
132Supply of IP65, 60W LED CDLdecorative street light for beautification application. Make: Empire ( Ref. Cat.No. LPTC 40 CDL) of CGL/ Vega of Surya or equivalent Syska, Havells, Philips, Jaquar,K/Lightas approved.
133Supply installation of Bollard Light
134Supply of 6 mtrs heightdecorative polewith inbuilddecorativeSINGLEarmmatching with the lamps set as described above. Please refer CGL decorative pole cataloguefor CGL set or for Surya makeset please refer corwndecorative pole oras approved for other company make decorative set.
135Supply and installation of Net Climber
136Supply and installation of Four seatter See-Saw
137Supply and installation of Merry go round
138Supply and installation of Cycling
139Supply and installation of Air Walker
140Supply and installation of Waist twister
141Supply fitting and installation of Garden Bench with back rest. ( AS PER QUOTATION)
142Machine boring of deep tube well upto 150mm dia. Bore hole asdirected by the Engineer in Charge
143Supply installation testing and commissioning of centrifugal pump (submersible/vertical/horizontal pump) of flow rate 220 LPM @ 50m head (One working and one standby)
144Supply fitting and installation of Two in one Swing
145Supply fitting and installation of Rowing Machine
146Silsako Park, North Guwahati
147EARTH WORK Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge. All kinds of soil.
148Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
149PLINTH FILLING: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
150CONCRETE WORKS: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
151REINFORCED CEMENT CONCRETE WORKS Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
152Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
153FORMWORK Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
154Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
155Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
156STEEL REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
157MASONRY WORK: Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in::: Cement mortar 1:4 (1 cement : 4 coarse sand)
158MASONRY WORK : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : Cement mortar 1:3 (1 cement :3 coarse sand)
159CEMENT PLASTERING 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
160Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
161Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
162Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
163VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 300x300 mm
164WPC DOOR FRAME Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Celestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 150 mm
165DOOR SHUTTER: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick
166UPVC WINDOW : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.::Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
167ANTISKID TILES Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Antiskid finish of size Size of Tile 300x 300 mm
168Precast RCC Rectangular Covers Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
169PCGI ROOFING Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
170Applying priming coat: (Truss) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
171Flooring ( Stage) Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
172Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work (Truss)
173M.S. GRILL: Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
174Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes
175Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes
176Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes
177Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete25 mm nominal bore
178SOAK PIT Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
179Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
180Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining, fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
181Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
182UNDERGROUND CABLE Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to35 sq. mm
183Supplying and fixing 5 amps to 32 amps rating, 240 / 430 volts, 10 KA"C" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 16A
184Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
185Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivitycurrent 30mA intheexisting MCBDB complete with connections, testing and commissioning etc. as required for rooms and media room. 40A
186Earthing withG.I.earthpipe4.5metrelong,40mmdia cover plate having locking arangement and watereing pipe with charcoal / coke andsalt as requiredfor out doorlighting system& indoor DBs. One for VTPN and 1 forwashr room and1 for cofee house .
187Supplying and drawingfollowingsize of FRLS PVC insuleted copper conductor, single core cable in thr existing surface/recessed steel/PVC conduit as required1.17. 1x17.20 2x4 sq.mm
188Supply of IP65, 60W LED CDLdecorative street light for beautification application. Make: Empire ( Ref. Cat.No. LPTC 40 CDL) of CGL/ Vega of Surya or equivalent Syska, Havells, Philips, Jaquar,K/Lightas approved.
189Supply installation of Bollard Light
190Supply of 6 mtrs heightdecorative polewith inbuilddecorativeSINGLEarmmatching with the lamps set as described above. Please refer CGL decorative pole cataloguefor CGL set or for Surya makeset please refer corwndecorative pole oras approved for other company make decorative set.
191Supply and installation of Net Climber
192Supply and installation of Double bar See-Saw
193Supply and installation of Tubo Roto Slide
194Supply and installation of ARC Swing Rubber Belt
195Supply and installation of Multiplay station
196Supply and installation of Leg press
197Supply and installation of cycling
198Supply and installation of wsist twister
199Supply and installation of Two level Chin Up
200Supply and installation of all purpose dustbin
201Push and Pull Chair
202Supply fitting and installation of Garden Bench with back rest. ( AS PER QUOTATION)
203Machine boring of deep tube well upto 150mm dia. Bore hole asdirected by the Engineer in Charge
204Supply installation testing and commissioning of centrifugal pump (submersible/vertical/horizontal pump) of flow rate 220 LPM @ 50m head (One working and one standby)
205Repairing of artistic work: Entry Gate and Statue of garden
206Supply and installation of Fountain.
207Supply and Installation of Bust
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail