Tender For Repair/Maintenance Of Kitchen Toilet Exhaust System Fire Detection System And Other Misc Works Of Manekshaw Centre Under Ge (U) Pm Delhi Cantt-10, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Kitchen Toilet Exhaust System Fire Detection System And Other Misc Works Of Manekshaw Centre Under Ge (U) Pm Delhi Cantt-10. Submission Date for this Tender is 30-01-2024. Flame Detectors Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41407612
Corrigendum : Tender For Repair/Maintenance Of Kitchen Toilet Exhaust System Fire Detection System And Other Misc Works Of Manekshaw Centre Under Ge (U) Pm Delhi Cantt-10
Open Tender
Indian
Delhi
delhi
30-01-2024

Tender Details

Repair / Maintenance Of Kitchen Toilet Exhaust System Fire Detection System And Other Misc Works Of Manekshaw Centre Under Ge ( U ) Pm Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 83460.0 /-
Tender Value
INR 41.73 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINTENANCE OF KITCHEN / TOILET EXHAUST SYSTEM, FIRE DETECTION SYSTEM AND OTHER MISC WORKS OF MANEKSHAW CENTRE UNDER GE (U) P&M DELHI CANTT-10
Sl. No. Item Description
1Material and labour for de-scaling of condensers of central AC plantcapacity 3X270 TR by opening side plate, flushing the condenser tubes using de-scaling solution, Roding the condenser tubes carefully removing all the deposited materials completely and raising the solution through condenser tubes till clear water starts to come out from the condensers as complete including re-fixing the side plates by replacing gaskets & testing complete for satisfactory working at complete at Manekshaw Centre all as specified and directed. Notes :- (i)Necessary T&Psuch as pump, tube, descaling solution etc shall be arranged by the contractor without any extra cost to Department. (ii) Descalling of all condensers in one AC plant shall be considered as one job.
2Material and labourfor servicing of AHU unit including cleaning of bottom tray and cleaning of cooling coil complete with high pressure and coil shine solutionsand jet ofwater pressure with pump without damaging cooling coils and fins and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure through flow of air over the cooling coil, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc all as directed for following capacity AHU:-
318000 CFM AHU
47000 CFM AHU
54000 CFM AHU
68000 CFM AHU
714000 CFM AHU
822000 CFM AHU
96000 CFM AHU
1013000 CFM AHU
1113500 CFM AHU
1211000 CFM AHU
13Material and labourfor servicing of ceiling mounted AHU unit including cleaning of bottom tray and cleaning of cooling coil complete with high pressure vaccum cleaner without damaging cooling coils and fins and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure through flow of air over the cooling coil, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc all as directed for following capacity AHU:-
146000 CFMceiling mounted AHU
158000 CFMceiling mounted AHU
165000 CFMceiling mounted AHU
173000 CFMceiling mounted AHU
182000 CFMceiling mounted AHU
192500 CFMceiling mounted AHU
20Supply and fixing in repair of AHU Shaft bearing (02 Nos in each) of size for following capacityAHU as per site requirement complete all as specified and directed. (Make :- MTM/SKS or equivalent as approved by Accepting Officer.)
2118000 CFM AHU
227000 CFM AHU
234000 CFM AHU
248000 CFM AHU
2514000 CFM AHU
2622000 CFM AHU
276000 CFM AHU
2813000 CFM AHU
2913500 CFM AHU
3011000 CFM AHU
313000 CFMceiling mounted AHU
322500 CFMceiling mounted AHU
332000 CFMceiling mounted AHU
34Supply and topping up Refrigerator Gas R-134A complete all as specified & directed. (Make:- Mefron/ Floron/ Refron.)
35Material and Labour for disamtling the one side puff panel of AHU and then diconnecting the chiller pipe and cooling coil of AHU of required andthen Supply and fixing in replacement of bottom tray for fan and coil section of AHU of any size and any capacity made out of SS sheet tray of grade 304 and also including 25mm thick thermocol insulation covered with tarfelt for AHU bottom complete all as specified and directed.
36Supply and fixing in replacement of shock absorbing rubber pads at the bottom of the AHU unit for absorbing shocks and vibrations, heavy duty of suitable size as per ground requirement complete all as speicifed and directed.
37Supply and fixing in replacement of Pre filter 10 micron of size 610mm x 610x 50mm made of out of GI wire mesh interspaced with two crimp layers and three flat layers flanged deep box type and efficiency 90% as per existing size and pattern for the AC Plant air handling unit complete all as speicifed and directed. (Make :- Thermodyne/ AAF or equivalent as approved by Accepting Officer.)
38ditto- all as per item No. 8.00 above but size 610mm x 300mm x 50mm.
39ditto- all as per item No. 8.00 above but size 300mm x 300mm x 50mm.
40ditto- all as per item No. 8.00 above but size500mm x 450mm x 50mm.
41ditto- all as per item No. 8.00 above but size 500mm x 500mm x 50mm.
42ditto- all as per item No. 8.00 above but size 500mm x 400mm x 50mm.
43Supply and fixing in repair bimetallic thermaloverload relay,9 to 15 Ampscomplete as specified and directed.
44Supply and fixing in repair bimetallic thermaloverload relay,14 to 23 Ampscomplete as specified and directed.
45Supply and fixing in repair bimetallic thermaloverload relay,20 to 33 Ampscomplete as specified and directed.
46Supply and fixing in repair bimetallic thermaloverload relay,24 to 40 Ampscomplete as specified and directed.
47Supply and fixing in replacement of Rubber Tyre Coupling (TC-14) set for chiller / condensor pump motor complete all as specified and directed. (Make:- Unique or equivalent make as approved by Accepting Officer)
48Supply and fixing in replacement of Rubber Tyre Coupling (TC-13) set for chiller / condensor pump motor complete all as specified and directed. (Make:- Unique or equivalent make as approved by Accepting Officer)
49Supply and fixing in replacement of Rubber Tyre Coupling (TC-11) set for chiller / condensor pump motor complete all as specified and directed. (Make:- Unique or equivalent make as approved by Accepting Officer)
50Supply and fixing in replacement of multifunction electronic timer( 0 to 60 Sec) type Series 525 complete all as specified and directed. (Make:- Siemens/L&T/ ABB)
51Material and Labour for frame work with angle ironfor frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and asdirected.
52Material and Labour for repairing /servicing Condenser or Chillerpump (Centrifugal pump) of following capacities by disconnecting the pump from motor, opening for inspection, replacing the worn out parts like gland bush, bearings, gland bolts and nuts, gland packing, gasket, water seal etc including repairing to pump shaft by remetalling, grinding, polishing and reassembling complete pump & refixing in same position & connecting including replacing the rusted nuts, bolts, washers etc and testing and commissioning including loading/unloading and transportation to & from authorised workshopcomplete all as specified and directed: -
53Condenser or Chiller Pump of capacity 30 HP
54Hotwater generator Pump of capacity 25 HP
55Disconnecting from mains/taking out existing unserviceable/defectivemotor of following capacity of any size, type, and make including disconnecting all electrical connectionsremoving from foundation transporting to repair workshop disconnecting unserviceable burn out winding completely including insulating materials and rewinding of the complete stator with super enameled copper wire of existing size applying proper insulation ‘F’ class varnish drying in oven, assembling, transporting back to site, re-installating, testing and commissioning complete all as specified and as directed .
56Condenser or Chiller Pump of capacity 30 HP
57Hotwater generator Pump of capacity 25 HP
58Material and Labourfor repairing/ servicingAHU Fan Motor/ exhaust AHU of following capacity, opening themotor, cutting & removing old burnt windingwire, rewinding the motor with new super enamelled copper winding wire of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate,reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed :-
592 HP Motor
603 HP Motor
615 HP Motor
627.5 HP Motor
6310 HP Motor
6415 Hp Motor
65Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-32 includingNO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed.. (Make :-L&T/Siemens/ ABB/ C & S.)
66Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-25 includingNO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. (Make -L&T/Siemens/ ABB/ C & S.)
67Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-18 includingNO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. (Make :-L&T/Siemens/ ABB/ C & S.)
68Supply and fixing in replacement Rigid UPVC piping of following dia complete with fittings, supports as perspecifications and duly insulated with 6mm thick closed cell nitrile rubber insulation. (Make :- Supreme/ Finolex/ Prayag)
6940mm dia
7032mm dia
71Supply and fixing in replacement over load relay 30-50 Amps complete all as specified and directed. (Make :- L&T/Siemens/Legrand/ ABB/ C & S.)
72Supply & fixing in replacementbrass terminals of follwing ways complete all as specified and directed.
733 way
744 way
756 way
7610 way
77Material and Labour for control wiring with 6 coreX 1.5 sqmm sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694complete all as specified and directed (Make of wire :- Finolex/Havells/Polycab) (Make of PVC rigid conduct :- Finolex/ Supreme/ Presto plast)
78Supply & fixing in replacement single phasing preventer type VSP2 complete all as specified and directed . (Make:- Minilec/ L&T/ Siemens/Legrand/ ABB/ C & S.)
79Material and Labour in replacement of unserviceable 3 way modulating motorized valve with Teflon gland, with linear movement actuator 24 V AC input supply, 0-10 V input signal with modulating thermostat & transformerof following sizes completeall as specified and directed. (Make :- Honeywell/ Siemens/ Indfoss/ Johnson)
8032 mm dai
8165 mm dia
8250 mm dia
8340 mm dia
8480 mm dia
85100 mm dia
86Supply and fixing in replacement Water temperature sensor suitable chiller units of 270 TR as per existing model and makecomplete all as specified and directed.
87Supply and fixing in replacement Air Vent valves made out of brass of size 15mm dai for chiller chiller pipe line complete all as specified and directed .
88Supply and fixing moulded polyethylene water storage tank of capacity 200L(cuboidal type vertical with closed top) hoisted and fixed in position all as specified in SSR Part I allas directed and specified. (Make :- Sintex/ Polycon/ Rotex)
89Supply and fixing in replacement cast iron Y strainer flenged ends with SS perforated sheet screen of following size complete all as specified and directed. (Make: - ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO).
90100mm dia
91150mm dia
92200mm dia
9332mm dai
9465mm dia
9550 mm dia
9680 mm dia
97Supply and fixing in replacement cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of following size dai complete all as specified and directed. (Make: - ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO).
98300 mm dia.
99200 mm dia.
100150 mm dia.
101125 mm dia.
102100 mm dia.
10380 mm dia.
10450 mm dia.
10565 mm dai
106Supply, Laying, jointing and testing of under ground electric cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed . (Make :- Finolex/ Havells/ Polycab)
1074 core 10 Sqmm
1084 core 16 Sqmm
1094 core 25 Sqmm
1103.5 core 35 Sqmm
1113.5 core 50 Sqmm
1123.5 core 70 Sqmm
1133.5 core 95 Sqmm
114Supply and fixing in replacementmotorized spring return actuator for device with control panel and temprature sensor complete all as specified and directed.
115Supply , installation, testing and commission in replacement of fire dampers complete with smoke detector/ thermister linkage etc and actuator as required for operation complete all as specified and directed.
116Supply and fixing MS damper of size 450mm X 450mm of supply diffuser as directed and specified by engineer in charge.
117Material and Labour for control wiring with 4 coreX 4 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694complete all as specified and directed. (Make :- Finolex/Havells/Polycab) (Make of PVC rigid conduct :- Finolex/ Supreme/ Prestoplost)
118Material and Labour for control wiring with 4 coreX 6sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 40 mm dia as per IS 694complete all as specified and directed (Make :- Finolex/Havells/Polycab) (Make of PVC rigid conduct :- Finolex/ Supreme/ Presto plast)
119Material and Labour for control wiring with 2 coreX 1.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694complete all as specified and directed. (Make :-Finolex/Havells/Polycab) (Make of PVC rigid conduct :- Finolex/ Supreme/ Prestoplost)
120Material and Labour for control wiring with 2 coreX 2.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694complete all as specified and directed (Make :- Finloex/Havells/Polycab) (Make of PVC rigid conduct :- Finotex/ Supreme/ Presto plast)
121Material and Labour For Providing,fixing, testing and commissioning in replacement of Duct mounted inline fans ofG.I. construction, complete with centrifugal fan Size 315mm dai complete as specified and directed. (Make :- Otsberg(model No. CK315C)or equivalent inZECO, EDGEtech)
122Supply and fixing in replacement bakelite terminal plate of 6 way including brass studs, bolts and nuts etc suitable to match any make of 3 phase electric motors and capacity up to 30 HP complete all as specified and directed.
123Supply and fixing in replacement thermometer suitable for condenser water line with suitable housing for mounting on pipe line 0-50°C complete including taking down old unsv thermometer all as specified and directed. (Make :- Indfoss/ Renutrol).
124Supply and fixing in replacement Compound pressure gauge (Discharge pressure) of size 100 mm dia suitable for 0 to 300 PSI complete including taking down old unsv pressure gauge all as specified and directed . (Make :- Adarsh/Febic)
125Supply and fixing in replacement indicator lamp assembly complete LED type suitable for the existing system supply voltage 230V / 440V ACcomplete all as specified and directed. (Make:- MIMIC CONTROL/ GE CONTROLS / RR MICRO / L&T / SIEMENS/ BCH/ SCHNEIDER)
126Supply and topping up Compressor Oil RL-170 H complete all as specified & directed. (Make:- HPCL(Seetal)/ HP (Seetal)/ Servo.)
127Material and labourfor servicing of Exhaust AHU of capacity up to 10000 CFM including cleaning of bottom tray and with air pressure to sweep up all the particles andchecking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc all as directed and specified.
128Supply and fix in replacementGalvanised iron strip 32X6 mm as earth continuity conductor including fixing arrangement on suitable size insulator complete all as directed.
129Material and Labour earthing complete with GI plate electrode of size 600 x 600 x 6 mm thick bured directly in ground vertically at a depth not less 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 1.5 cm thick packed layer of charcoal of dust and common salt filling in alternate layers and making electrode connection by using GI strip of size 32X6 (up to 7 meter GI strip included) mm by means of bolts nuts check nuts and washers made of brass and earth strip protected by light grade 40 mm dia GI Pipe upto test point and connected to main switch board are main controlled board with provision of GI pipe medium grade 20mm bore for watering including funnel wire mass RCC pit cover and PCC Chamber pit with 1:2: 4 type C2 (including excavation earth work) all as specified and shown on plate No 5 of SSR Part-1.
130Supply, install, testing and commissioning in replacementof Duct insulation with 25mm thick Nitrile Rubber insulation of class "o" fire retardantwithMechanicalprotection over insulation with fiber glass cloth & UV paint (for exposedduct) for Ducts installed outside, (exposed to sunlight) complete all as specified and directed.
131Supply and fixing in repair MCB TP 63 Amps, capacity 10 KA, C curve including taking down old unsv one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
132Supply and fixing in repair MCB TP 40 Amps, capacity 10 KA, C curve including taking down old unsv one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
133Material and Labour for preparation of surfaces of Cenral AC Plant of capacity 3 x 270 TR at Manekshaw Centre for painting of trap door, condensers,chillers,compresors, Induction motors, pumps, hot water boiler, C channels, all pipe lines, valves and outer body of cooling towers and AHU"s with different colors following the color code system as directed by the site-in-charge.Job includes removing the old paint by rubbing, brushing and applying one coat of red oxide zinc chrome primer and two coats of Synthetic Enamel Paint (1st grade quality) complete all as specified and directed. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
134Supply & fixing MCCB 4 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 25 kA with thermal magnetic release including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
135Supply & fixing MCCB 4 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 25 kA with thermal magnetic release including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
136Supply & fixing MCCB 3 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
137Supply & fixing MCCB 3 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
138Supply & fixing MCCB 4 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
139Supply & fixing MCCB 3 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
140Supply & fixing MCCB 4 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
141Supply & fixingMCCB 3 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed . (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
142Supply & fixing MCCB 3 Pole of capacity 200 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
143Supply & fixing MCCB 3 Pole of capacity 250 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed .. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
144Supply and fixing in replacement V-belt of size SPA-1120 complete all as specified and directed by Engr-in-Charge. (Make - Feener or equivalent as approved by Accepting Officer.)
145ditto- all as per item No. 71.00 above but size SPA-1750
146ditto- all as per item No. 71.00 above but size SPA-1850
147ditto- all as per item No. 71.00 above but size A-1610
148ditto- all as per item No. 71.00 above but size SPA-1800
149ditto- all as per item No. 71.00 above but size B-2350
150ditto- all as per item No. 71.00 above but size A-1630
151ditto- all as per item No. 71.00 above but size SPB-1320
152ditto- all as per item No. 71.00 above but size SPA-1550
153ditto- all as per item No. 71.00 above but size A-2270
154ditto- all as per item No. 71.00 above but size SPA-900
155Material and Labour for replacement ofchilled water pipe line insulation on MS class "C" pipe insulation of size 50 to 100 mm dia inside the building but excluding valves/strainers/pr gauges etc and adequately supported on rigid supports and duly insulated withclosed cell elastometric nitrile rubber of class "O" insulation and insulation applied by adhesive confirming to standard OEM specifications secured with 0.63 mmGI sheet cladding complete at the joints and repairing of damage to the buildings if any etc as per specifications and as required complete in all respects
156All same as of intem No. 82.00 but pipe of size 100mm to 200mm
157Supply and fixing in replacement 80 mm dia cast iron non return valves of pressure class PN 1.6 including nuts, bolts, washers, gaskets, etc for Central type AC plants complete all as specifed and directed. (Make: - ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO).
158ditto- all as per item No. 84.00 above but 100mm dia
159ditto- all as per item No. 84.00 above but 150mm dia.
160Ditto- all as per item No. 84.00 above but 250mm dia.
161Supply, Installation , Testing and commissioning in repair of perfabricated type cable tray of size 45mm wide x 50mm x 1.6mm fabricated out of perforated hot dip galvanized sheet of minimum 1.6mm thick with 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed.
162All as per Item No.88.00 above but of size75mm wide x50mm x 1.6mm complete all as specified and as directed.
163All as per Item No.88.00 above but of size150mm wide x50mm x 1.6mm complete all as specified and as directed.
164Material and Labourfor Supply, fixing of powder coated extruded aluminum rectangular diffusers complete with black anodized extruded aluminum VCD (wherever specified), nuts, bolts, screws etc.complete as required at site all as specified and directed.
165Supply air diffusers (outer size 305mm X 305mm) of required sizes with volume control damper.
166Supply air diffusers (outer size 610mm X 610mm) of required sizes with volume control damper.
167Return air diffusers(outer size 150mm X 105mm) of required sizes without volume control damper
168Return air diffusers(outer size 305mm X 305mm) of required sizes without volume control damper
169Return air diffusers (outer size 610mm X 610mm) of required sizes without volume control damper
170Material and Labour for Supply & Fixingofpowder coated extruded aluminum supply & return grilles complete with nuts, bolts, screws etc. to make the system complete, as required at site all as specified and directed.
171Material and Labourfor Supply and installation in replacement of thermal insulation material for non-exposed Ducts with closed cell class o nitrile rubber elastomeric insulation of density 40-60 Kg/m3 thermal conductivity of 0.033-0.038 W/mk and µ>=7000 (k-flex st) to be applied on ducts using manufacturers recommended rubber based adhesive as per the approved specification the material shall be from global approved & UL approved for new ducts as required at site complete all as specified and directed.
172(b) 19 mm thick
173(a) 25 mm thick
174Material and Labour for Supply, installation, testing and commissioning in replacement of flexible fire retardant canvas connector cloth including flanged from both side with inspection chain in it removing of old one complete all as specified and directed.
175Supplyand fixing in replacementrubber mat LT 1.1KV volt grade 1mtrx 2mtr x 10mm
176Supply & fixing in replacement aluminium lugs for cable of cross sectional area 10 Sqmm complete all as specified and directed.
177Supply & fixing in replacement aluminium lugs for cable of cross sectional area 16 Sqmm complete all as specified and directed.
178Supply & fixing in replacement aluminium lugs for cable of cross sectional area 25 Sqmm complete all as specified and directed .
179Supply & fixing in replacement aluminium lugs for cable of cross sectional area 35 Sqmm complete all as specified and directed by Engineer-in-charge.
180Supply & fixing in replacement aluminium lugs for cable of cross sectional area 75 Sqmm complete all as specified and directed.
181Supply & fixing in replacement aluminium lugs for cable of cross sectional area 95 Sqmm complete all as specified and directed.
182Supply & fixing in replacement aluminium lugs for cable of cross sectional area 120 Sqmm complete all as specified and directed.
183Supply & fixing in replacement copper lugs for cable of cross sectional area 10 Sqmm complete all as specified and directed .
184Supply & fixing in replacement copper lugs for cable of cross sectional area 16 Sqmm complete all as specified and directed.
185Supply & fixing in replacement copper lugs for cable of cross sectional area 25 Sqmm complete all as specified and directed.
186Material and labour for maintenance of AHU supply panel / feeder pillar/LT panel indoor/outdoor type including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends fresh and supply and crimping new thimbles/lugs and fixing the cable on bus bar/MCCB/Main switch/MCB including providing new nut bolts and washer if required greasing the doors of feeder pillar/LT panel outdoor/indoor type complete all as specified & directed .
187Attending complaint of control panel wiring and making it fully serviceable with and including PVC tape, PVC tie, Nut bolt, and other items complete all as specified and directed. Notes : - After intimation ofbreakdownby Engineer in Charge/JE E&M through telephone or verbally, the contractor shall arrange theMechanic to attend the complaint within 2 hours and make the plant functional.If contractor failed to attend complaint with in time frame, a penalty of Rs 400/- per Hrs per complaint shall imposed on contractor and shall be recovered from contractor"s dues
188Cleaning of inside surface of supply ducts of HVAC (minimum open area of duct 1.00Sqm and maximum area 16.00Sqm) system of any area using high power vacuum air compressor robotic camera, air hammer, special nozzles, air sweep with other required accessories given/showing inspection of dust before and after cleaning of duct using colour video inspection complete all as specified & as directed .
189Material and Labour for servicing of LT ACB 1600 Amps, 1200 Amps or 600 Amps draw out type 415 volts, 50 Hz, brushing, greasing and tightening of nuts and bolts fixed and movingcontacts for smooth functioning and replacing of minor accessories complete all as specified and directed.
190Material and Labour in repair of site fabricated GSS Sheet metal, rectangular/round ducting complete with neoprene rubber gaskets,elbows,splitter damper vanes,hangars,supports as per approved drawings and specifications of following sheet thickness complete. (Make :- Sail/ Tata/ Jindal)
1910.63 mm thickness sheet (24 gauge)
1920.80 mm thickness sheet(22 gauge)
193Inspection, checking, cleaning, testing and commissioning of fire alarm cum fire detection system complete including fire detectors, smoke detectors, heat detectors, response indicators, wiring etc. through trained/experianced technician of OEM, the system and carry out planned maintenance in systematic and controlled manner at Manekshaw centre building complete except new server room all as specified and directed .
194Notes for Serial item No 111.00 (a) Fire Alarm control panel:- These shall be kept clean by checking for its controls, indicating equipment’s system and all operations/fault indicators including checking of panel circuits for its healthiness and including of healthy battery/UPS/battery charger system. (b) Smoke Detectors &Fire Detectors: - All smoke/fire detectors shall be removing dust/dirt accumulated on them due to local ambient conditions. These shall be tested & cleaned once in a quarterly and report shall be maintained as directed by Engineer-in-Charge duly signed by user and concerned JE/Engineer-in-charge. (c)Response Indicators, Manual Call Point and Hooter:All items which are installed inside a cabin, room or above ceiling shall be tested by actuating the particular detectors every quarterly so as to ensure proper functioning of indicator. (d) Wiring and cables:Complete wiring shall be inspected jointly by contractor, MES rep and users so that structure or occupancy changes doesn"t damage the cable/wiring/trigger device (Manual call points smoke heat ionization detector etc) (e)During attending complaint and quarterly maintenance check any spares/items required forreplacemnet will done by the technician of OEM (i.e detectors, panels, response indicators, hooters wiring, battery) (f) Quarterly maintenance schedule submit by the contracor to the Engineer-in-Charge for his approval before going to the quarterly check.
195(g) Deployed Technician/mechanic fully equiped with necessary tools and plants are deemed to be included in the quoted rate. (h) Arrangement of testing equipment provided by the contractor deemed to be included in quoted rates. (i) The mechanic shall also be in possesion of mobile and two wheeler for communication and mobility. (j) The contractor deemed to have visited the site and seen the scope of work before quoting the rates. (l) Quarterly inspection test report will be submitted to deptt duly signed by user/ Engr-in-Charge. (m) Mock drill will be conducted once in quarterlyin presence of user after completion of cleaning and testing. (n) Adequate manpower shall be deployed at site to carried out for quarterly maintenance check as per CA provision. (o) All the work mentioned in notes above are deemed to be included in the quoted rates. (p) The rates for making necessary arrangement of scaffaolding/ ladders is deemed to be included in the quoted rates. (q) Any damage to smoke and fire detection system during maintenance shall be repaired by the contractor at his own cost.
196Checking and attending day to day complaints by means of finding the faultsonlyrelated to fire alarm, detectors, hooters, response indicators, wiring and all other accessories and fixtures maintained by the department complete all as specified and directed. NOTE :- (i) The rate of this item are included for attending of complaints only. (ii) Taking down of unserviceable materials and fixing of new materials will be measured and paid seperately under relevent items as mentioned in Section-IV here-in-after. (iii) Complaints shall be attend any time from user/MES rep without fail, failing which recovery of rate Rs 1000/- per complaint shall be effected from the RARs/FB. (iv) Minor materials such as PVC wire of any size as per requirement upto 1.0 mtr length, thimble, electric tape, fixing accessories, etc shall be deemed to be included in the quoted rate of this itmes. (v) The complaints shall be attend and defects shall be rectified within 08 Hrs commencing from date and time of notifing the complaint, failing which a penauly Rs 1000/ per complaint shall be leived/imposed on the contractor and recovery shall be made from his dues. (vi) Contractor shall be arrange suitable T&P incl necessary ladder and scaffolding for approach and safety measures to make it functional complete all as specified and directed. The rates for which are deemed to be included in the quoted rate.
197Supply and fixing of Multi Detector, optical type low current draw, wide operating voltage 8 to 30 VDC, Bi-colour LED detector status indicator, Automatic drift compensation, tested and approved to EN54 - 7:2000 (Amendment 1)including taking down old unserviceable one complete all as specified and directed. (Make :- APPOLO / EDWARD / SEIMENS/HONEYWELL).
198Supply and fixing of response indicators with MS Box 16 SWG and plastic coverincluding taking down old unserviceable one complete all as specified and directed . (Make :- APPOLO / EDWARD / SEIMENS /AGNI).
199Supply and fixing of maintanance free battery 7 AH, 12 Volts with 8 Hours backup and 12 months warrantyincluding taking down old unserviceable one complete all as specified and directed . (Make:- EXIDE/ AMARON/ STANDARD FURKKAVA)
200Supply and fixing of PVC conduit pipe medium grade size of 25mmincluding taking down old unserviceable one complete all as specified and directed. (Make- Kalinga/ Polycab/Finolex/ Havells/ Anchor).
201Supply and fixing of multi-stranded copper conductor cable 1.5 Sq. mm nominal cross-sectional area, two core, PVC insulated and unsheathedFRLSH cable 1100 volts grade for sub main wiringincluding taking down old unserviceable one complete all as specified and directed. (Make :- Havells/Polycab/Finolex/ RR Kabel)
202Material and labour for rectification, maintenance of addressable zones, searching the faults, up/down loading software of main control panel at Manekshaw center and reprogramming entire system and testing by authorized Technical Engineer of OEM complete all as directed by Engr-in-charge. and including Inspection, testing and commissioning of complete fire alarm system installed done by authrized OEM of Honywell manufacturer only all as required complete all as specified and directed .
203Supply, fixing, commissioning and testing of automatic Floating Sensitivity type Analog addressable Acclimate Photo thermal smoke detector with mounting based LED, Address Switch from 01-159 , to programme the detectors, complete as required. (In Changing Environment Area) ul- 7th editionincluding taking down old unserviceable one complete all as specified and directed. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
204Supply, fixing, commissioning and testing of analog addressable Rate of Rise Cum Fixed temperature detector with mounting based LED, Address Switch from 01-159 , to programme the detectors complete as required. Ul- 7th editionincluding taking down old unserviceable one complete all as specified and directed. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
205Supply,fixing,testing and commissioning of addressable type fault for isolating module shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base Model)including taking down old unserviceable one complete all as specified and directed . (Make: - NOTIFIER GST/APPOLO/ EDWARD/HONYWELL).
206Supply and fixing of addressable control modules for Hooters / Sounders / Strobes etc. including taking down old unserviceable one complete all as specified and directed. (Make : - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
207Supply and fixing of Strobe Lights Cum Hooter with 110 cd. The strobes shall be synchronized for better evacuationincluding taking down old unserviceable one complete all as specified and directed . (Make:- NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
208Supply and fixing of manual call pointincluding taking down old unserviceable one complete all as specified and directed . (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
209Supply and fixing in replacement oflinear BEAM type smoke detectorconsistingof a combined transceiver unit and an accompanying reflector which is to be fitted with all technical specifications as under :- 1. The distance between opposite walls is to be kept between 10 and 80 m from one another. If required, special additional stable ball joint units may be used to ensure that they are precisely fitted. The infrared beam that is emitted by the transmitter and is to be bounced back by the reflector and to be evaluated by the receiver. This is to be done by measuring the absorption of the infrared beam and of the smoke or fire modulation. The detectors shall get individually adapted to local conditions in the event of there being difficult visible conditions like strong interference from foreign light sources, reflections or very short monitoring distances etc. The beam detector shall be connected to the loop line via. individual monitor/ IO module to enable the detector being addressable and it shall operate in separate DC supply of 12 – 24 V