Tender For Provision Of Storage Accommodation For Ecc And E Clo Incl Scme Stores At Haws Gulmarg Under Ge 969 Ews., Baramulla-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provision Of Storage Accommodation For Ecc And E Clo Incl Scme Stores At Haws Gulmarg Under Ge 969 Ews.. Submission Date for this Tender is 27-01-2024. Building Work Tenders in Baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41401608
Corrigendum : Tender For Provision Of Storage Accommodation For Ecc And E Clo Incl Scme Stores At Haws Gulmarg Under Ge 969 Ews.
Open Tender
Indian
Jammu And Kashmir
Baramulla
27-01-2024

Tender Details

Tender For Provision Of Storage Accommodation For Ecc And E Clo Incl Scme Stores At Haws Gulmarg Under Ge 969 Ews. ; 1 Surface Excavation N.Exc 30Cm Deep And Averaging 15Cm Deep And Getting Out In Soft / Loose Of Soil Complete All As Specified And` Directed. 2 Excavation In Trenches N.Exc 1.50M Wide And N. Exc 1.50M In Depth And Getting Out In Soft / Loose Of Soil Complete All As Specified And` Directed. 3 Excavation In Trenches N.Exc 1.50M Wide And N. Exc 1.50M In Depth And Getting Out In Hard / Dense Of Soil Complete All As Specified And` Directed. 4 Excavating Over Areas, N Exc 1.5M Deep And Getting Out In Hard / Dense Soil, Complete All As Specified And` Directed. 5 Returning, Filling In Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25Cm Complete All As Specified And` Directed. 6 Removing Excavated Material N Exc 50M And Depositing Where Directed At A Level N Exc 1.5M Above The Starting Point Complete All As Specified And` Directed. 7 M&L Pcc Type C2 1:3:6 ( 40Mm Graded Aggregate ) In Foundations, Filling And Mass Concrete Complete All As Specified And` Directed. 8 M&L Pcc Type D2 1:4:8 ( 40Mm Graded Aggregate ) In Foundations, Filling And Mass Concrete Complete All As Specified And` Directed. 9 M&L 75Mm Thick Pcc Type E2 1:5:10 ( 40Mm Graded Aggregate ) In Foundations, Filling And Mass Concrete Complete All As Specified And` Directed. 10 M&L Random Rubble Masonry Built In Cement Mortar 1:4 Uncoursed, Well Bonded, Bedded And Solidly Hearted Complete All As Specified And` Directed. 11 M&L For Shingle Filling In Floors Or Pavings, Laid In Layers N Exc. 15 Cm Thick, Spread, Levelled, And Blinded With Earth And Rammed Including Watering Complete All As Specified And` Directed. 12 M&L Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc. 6M Mean Radius Built In Cm 1:4 Complete All As Specified And` Directed. 13 Extra Over Stone Walling For Hammer Dressing On Face From Straight Edge Held Against The Dressed Surface N Exc. 40Mm To Face Stones And Dressing Of Face Beds And Joints, As Specified, Of Random Rubble Walling, Uncoursed Or Brought Upto Courses For Granite Ot Trap Complete All As Specified And` Directed. 14 Flush Pointing In Cement Mortar 1:4To Random Rubble Masonry, Uncoursed Or Brought Upto Courses Complete All As Specified And` Directed. 15 M&L For Boulder Filling Dry Hand Packed ( Any Thickness ) At Back Of Walls Over Arches Etc. And Raising ( Or Lowering ) To The Required Level Complete All As Specified And` Directed. 16 M&L Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Radius In Half Brick Thick Walls Built In Cm 1:4 Complete All As Specified And` Directed. 17 M&L For Pcc 1:2:4 Type B-0 ( 12.5Mm Graded Aggregate ) As In Coping, Plinth Band , Bed Block Including Rounded Or Chamfered Angle As Directed Including Necessary Formwork Etc Complete All As Specified And` Directed. 18 Material And Labour For Plain Cement Concrete 1:2:4 Type B-1 ( Using 20Mm Graded Mechanically Crushed Stone Aggregate ) As In Surface Channels And Drains, Complete All As Specified And Ditected. 19 M&L Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length Bent To Shap Required Including Cranking, Bending Spirally For Hooping For Columnshooking Ends And Binding With And Including Mild Steel Wire ( Annealed Not Less Than 0.9 Mm Dia Or Secur;Ing With Clips Quality Conforming To Fe-410-S Or Fe 410-0 Complete All As Specified And` Directed. 20 Ditto As Per Itemno 18 Above But8 Mm Dia Bars As In Stirrups / Spacers Complete All As Specified And Directed. 21 M&L Rendering 10Mm Thick Plaster On Internal Face Of Wallin Cm 1:6 Finished Even And Smooth Without Using Extra Cement Complete All As Specified And` Directed. 22 M&L Rendering 15Mm Thick Plaster On Stone / Brick Masonary Surface Or Other Than Fair Faces Of Brick Work In Cement Mortar 1:4Finished Even And Smooth Without Using Extra Cement Complete All As Specified And` Directed. 23 M&L Rendering 15Mm Thick Plaster On Stone / Brick Masonary Surface Or Other Than Fair Faces Of Brick Work In Cement Mortar 1:4 Mixed With Water Proofing Compound Complete All As Specified And` Directed. Note: Wpc Shall Be Measured And Paid Separately. 24 Supply Only Liquid Water Proofing Compound Isi Marked Complete All As Specified And Directed. 25 Supply And Fixing Pressed Steel Doors Frames Of Size 105 Mm X 60 Mm With One Or More Rebates Including Fixing Necessary Lugs, 3 Nos 100 Mm Long Hinges Per Shutter , Lock Strike Plate Etc. Including Making Good The Disturbed Portion To Match With Existing Complete All As Specified And Directed. 26 S&F Prepainted Galvalume Aluminium Zink Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screwincluding Necessary Scaffolding, Anytype, Any Location / Height Complete All As Specified Anddirected By Engr-In-Charge. 27 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Including Necessary Scaffolding, Anytype, Any Location / Height Complete All As Specified Anddirected By Engr-In-Charge. 28 S&F Factory Made Box Type Steel Ventilators With Centre Hung Shutter Including Two Pairs Of Brass Cup Pivots, Catch Spring And Pulley Wheel, Complete All As Specified Anddirected By Engr-In-Charge. 29 Supply And Fixing Factory Made Box Type Steel Windows With Side Hung Shutters Including Projecting Type Hinges With Steel Handle And Steel Peg Stay Complete With Glazing Barscomplete All As Specified. 30 M&L Preparation Of Newly Plaster Surface Andapplyingtwo Coat Of Cement Base Paint Over A Coat Of Primercomplete All As Specified And` Directed. 31 M&L Preparation Of Newly Plaster Surface Andapplying Two Coat Of Oil Bond Distemper Over One Coat Of Putty Complete All As Specified And` Directed. 32 Material And Labour For Plain Cement Concrete 1:3:6 Type C1 Using 20 Mm Graded Mechanically Crushedstone Aggregate As In Cills, Steps, Copings, Bed Plates, Kerbs, Hold Fasts Blocks Etc Including Weathering Slightly Rounded Or Chamfered Angles Of Throating Includingnecessary Form Work To Concrete Surfaces Complete All As Specified And Directed. 33 Preparing Surfaces Of New Steel And Iron Work Of Any Description And Girth, Not Otherwise Described, And Treated With Tar Or Coal Tar Black Painttreating Small Articles Such As Stop, Covers, Gully Gratings, Holdfasts, Ends Of Posts, Backs Of Chowkats, Etc., Area N Exc 0.1 Sq. M Each Complete All As Specified And Directed. 34 S&F Fi 25X3mm For Bands, Straps, Supports Or Stays For Rainwater, Ventilating Pipes, Including Bolts, If Required: Hooks ( Stay ) , Heavy, For Large Gates; Hook And Pintle Hinges: Large Hasps And Staples; Chains; Hand Made Sliding Bolts; Clamps; Hold Fasts; Wall Ties; Hooks For Hanging Fans; Plain Angle Cleats For Securing Purlins To Wood Trusses Or Rafters; Knee Piece Inserts; Two Way And Three Way Straps, Plate Washers And Similar Small Articles Conforming To Fe-290 Gde-E-165 Complete All As Specified And` Directed. 35 Supply And Fixing Mild Steel Section Such As In Roof Truss, Rails, Purlin As In Framed Work For Roof Covering Including All Flange, Cutting, Welding, Drilling Holes For Screws Including Distance Pieces And Cleats Etc Complete All As Specified And Conforming To Fe 410-0 W ( Gde-E-250 ) Quality-A Complete All As Specified. 36 Material And Labour For Preparation Of Newly Steel And Iron Surfaces Of Any Description Not Otherwise Described Over 10 Cm In Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer Complete All As Specified And` Directed. 37 Material And Labour For Preparation Of New Or Previosly Untreated Wood And Wood Based Surfaces Of Any Description Not Otherwise Described Over 10 Cm In Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over One Coat Of Pink Primer Primer Complete All As Specified And` Directed. 38 M&L Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section And Fixed 150 Mm Isi Marked Complete All As Specified And` Directed. 39 M&L Mild Steel Sliding Door Bolts, Plate Type, Stove Enamelled Black, With Bright Bolt Not Less Than 12Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, Four On Bolt Plate And Two On Staple Plate And Fixed 250Mm Isi Marked Complete All As Specified And Directed. 40 M&L Aluminium Oval Type Handles, Cast Type, Anodised 150Mm Complete All As Specified And Directed. 41 S&F Sheet Glass 4 Mm Thick, Figured Glass, Pin Head Type And Glazing With Oil Putty In Square Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. 42 S&F Factory Made 35Mm Thick Second Class Soft Wood Plain, Framed, Panelled Shutters ( Any Number Of Panels ) , With Panels Of Timber Flat On Both Sides ( Feather Edged ) , Or Of Veneered Particle Board Medium Density, Wood Particle Board With Commercial Face Veneers: Supplied And Fitted To Chowkats Complete All As Specified And Directed. 43 M&L Hardcore Of Gaugeexc. 63Mm But Not Exc 100Mm, Deposited, Spread And Levelled In Layers N Exc. 150Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And` Directed. 44 M&L For 25Mm Thick Pcc 1:2:4 Type B1 ( Using 20Mm Graded Crushed Stone Agg ) As In Sub Base & Floor Base Complete All As Specified And Directed. 45 M&L For 75Mm Thick Pcc 1:4:8 Type D2 ( Using 40Mm Graded Crushed Stone Agg ) As In Sub Base & Floor Base Complete All As Specified And Directed. 46 Supply Andfixingpcc Coloured , Rubber Moulded , Interlocking Designer Paver Blocks ( Double Glossy ) In Any And Shape, Confirming To Is-15658-2006 Of 60Mm Thickness, M-35 Gradein Path, Hard Standing, Etc. Laid Over And Including 50 Mm Thick Screed Or Bedding Layer Of Sand, Complete All As Specified. 47 M & L For Sand Filling Under Floors Or In Foundations Including Watering And Consolidation, Complete All As Specified And` Directed. 48 Material Andlabour For Plain Cement Concrete, 1:2:4 Type B-1 ( Using 20 Mm Graded Mechanical Crushed Aggregate ) For Levelling Course, Benching, Coving, Roof Kerbs Mixed With Acrylic Bases Polymer Water Proofing Compound, Complete All As Specified Anddirected .Note- Supply Only Acrylic Based Polymer Water Proofing Compoundshall Be Measured And Paid For Separately. 49 M&L Damp Proof Course To Horizontal Or Verticalsurfaces Including Necessary Formwork, 40Mm Thick In Cement Concrete 1:2:4 Type-B-0 Using 12.5Mm Graded Stone Aggregate Complete All As Specified And Directed. 50 M&L 25 Mm Thick Pcc ( 1:3:6 ) Type C-1 ( Using 20 Mm Graded Crushed Stone Aggregate ) As In Plinth Protection, Surfaces Finished Even And Fair, Complete All As Specified And Directed. 51 Gl Frame Work For Seamless Ceiling Comprising Of Gl Perimeter Channnel 0.55 Mm Thick With Two Unequal Flanges Of 20 And 30 Mm And Web Of 27 Mm Fixed To Surrounding Wall Using Nylon Sleeves And Screws At 450 Mm Centre To Centre / Intermediate Channel 0.9 Mm Thick Having Two Equal Flanges Of 15 Mm Each And Web Of 45 Mm Suspended From Soffit At Approx 900 Mm Centre To Centre With Gl Cleat And Steel Expansion Fasteners With And Including Ceiling Section ( Not Exc 1.2 M Length ) Of 0.55 Mm Thickness Having Kurled Web Of 50 Mm And Flange Of 26 Mm Each With Lips Of 10.5 Mm Fixed To The Intermediate Channel With Connecting Clips Across The Intermediate Channel At 457 Mm Centre To Centre, Complete All As Specified And Directed. 52 Material And Labour For Machine Cut Kota Stone Slab 20-25Mm Thickas In Flooring, Laid Over And Including Cement Screed Bed 20 Mm Thick In Cement Mortar 1:3, And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Granite Polishing Complete All As Specified. 53 M&L Formachine Cut Kota Stone Slab Flooring 12-15 Mm Thick As On Vertical Surfaces Such As Skirting / Dadosover 10 Mm Rendering In Cm 1:3 Height Of Skirting 100 Mm And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Granite Polishing Complete All As Specified And Directed. 54 M&L For 110Mm Dia Pvc ( Swr ) Pipes Isi Marked Single Socketed In Any Length With Rubber Ring Joints As In Weep Holes Etc Complete All As Specified And` Directed. 55 M&L For Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams; And Similar Work; Verticle Or To Batter Withrough Finish Flat Surface Complete All As Specified And Directed. 56 M&L For Form Work To Sides Of Pillars, Posts, Struts, Pears, Columns & Stanchion Square Or Rectangularor Polygonal Etc With Rough Finished Surface Of Concrete Complete All As Specified And As Directed. 57 M&L For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelvves Including Sup-Ports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc Finish Withrough Finish Flat Surface Complete All As Specified And Directed. 58 M&L Rcc M-30 ( Design Mix ) As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc; Basement Slabs, Under-Reamed Piles And Mass Concrete Completet All As Specified And Directed. 59 M&L Rcc M-30 ( Design Mix ) As In Columns, Pillars, Piers, Posts And Struts Completet All As Specified And Directed. 60 M&L Rcc M-30 ( Design Mix ) As In Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span Completet All As Specified And Directed. 61 M&L For Rcc 1:2:4 Type B-1 Using 20Mm Graded Mechanically Crushed Stone Aggregate As In Lintels Upto 1.5M Clear Span, Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For Inclduing Necessary Form Workcomplete All As Specified. 62 Providing And Fixing 10Mm Thick Plaster Of Paris Ceiling ( Gypsum Anhydrous ) To Flat Surface Over Seamless Ceiling Fillets Or Metal Frame Work And Reinforced With G.I. Wire Mesh Complete All As Specified. 63 Extra For Forming Fair Finished Drain Or Channel 30Cm Inner Girth In Cement Concrete, Using Extra Cement, Including Forms, Moulds, Mitred / Stopped Ends Etc. Complete All As Specified And Directed. 64 M&L Precast Cement Concrete B1 Type, ( 1:2:4 ) Using 20 Mm Graded Aggregate Set In Cement Moertar 1:6 In Bond Stones For Stone Masonary And The Like Including Necessary Formworketc Complete All As Per Specified And Directed. 65 Point Wiring For One Light Point / Fan Point Controlled By One Switch With 1.5 Sqmm Pvc Frls Insulated Un-Sheathed Copper Conductor Single Core Multi Strand Flexible Cable And 1.5 Sqmm Pvc Frls Insulated Un-Sheathed Copper Conductor Single Core Multi Stranded Flexible Cable ( Green Color ) As Earth Lead In And Including Cable 1100 Volts Grade Including Pvc Casing And Capping / Conduit ( Isi Marked ) For One Light / Fan Point Including 2Nd Class Hard Wood Rectangular Block Open Recessed Cover With 3Mm Thick Plastic Laminated Sheet Cover Including Cutting Chases To Wall Making Good The Disturbed Surfaces To Match With Theexisting Specification Complete All As Specified. 66 All As Per Item No 65 Herein Before But Wiring With 2.5 Sqmm Copper Wire ( Frls ) And 2.5 Sqmm Earth Wire For Socket Outlet 3 Pin 5 Amps On Same Board Complete All As Specified And` Directed. 67 All As Per Item No 65 Herein Before But Wiring With 1.5 Sqmm Copper Wire ( Frls ) And 1.5 Sqmm Earth Wire For Socket Outlet 3 Pin 5 Amps On Independent Board Complete All As Specified And` Directed. 68 S&Fswitch Piano Flush Button Single Pole, One Way 6 Amps 240 Volts Including Taking Down Complete All As Specified And Directed. 69 S & F Switchsocket Combination 2 In 1, 3 Pin 5A, Flush Type Universal Complete All As Specified And Directed . 70 S & F Switchsocket Combination 2 In 1, 3 Pin 15A, Flush Type Universal Complete All As Specified And Directed . 71 S&F Of Distribution Board Single Pole & Neutral With 200 Amps Rated Bus Bar, For Double Door Ip-42 DbS , Made Outof Sheet Steel Enclosure, Recessed Type, Factory Made Powder Coated 8 Way -415 Volts Suitable For Housing McbS And IsolatorS Complete In All Fixing Material / Accessories Etc Complete All As Specified And Directed. 72 S&F McbS Single Pole 240 Volts 6 To 32Amps 10 Ka BCurve Series, All As Specified And As Directed By Engr -In-Charge. 73 S&F McbS Single Pole 240 Volts 40 To 63Amps 10 Ka CCurve Series, All As Specified And As Directed By Engr -In-Charge. 74 M & L In Repairlamp Holder, Pvc / Polycarbonate Type With Cord Grip Cap Suitable For Pendant Fittings Complete All As Specified And Directed 75 S&F Led, 20 Watts, 4 Ft, 220V Ac Fittings Decorative Box Type With Driver Complete With All Accesories For Mounting Light Fittings Complete With Earth Terminal Connection, 3 Terminal / Pvc / Polycarbonate, Isolated Body Complete All As Specified And Directed. 76 Supply And Fixing Ceiling Rose With Earth Terminal Connection, 3 Terminal / Pvc / Polycarbonate, Isolated Body Complete All As Specified And Directed. 77 Material And Labour For Earthing Complete With Galvanised Steel, Earth Plate Electrode 600Mm X 600Mm X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtrs Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.65 Mtrs Below Normal Ground Level Connected To Galvanised Earth Lead Wire 4Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron / Steel All As Shown In Electrical Plate No 5 On Page 19-49 Of Mes Schedule 1991 Part I Connected To Main Switch Board / Main Dbs / Earthing Test Point Including All Necessary Excavation And Earth Work In Hard / Dense Soil Common Salt And Charcoal Dust Mixed And Packed 150Mm Thick All-Round The Gi Earth Plate, Watering Pipe 20Mm Dia Gi Medium Grade.Gi Sheet 0.63Mm Thick Funnel, Wire Gauge, 50Mm Thick Rcc Cover In Pcc 1:2:4 Type B1 Duly Reinforced With Ms Round Bars 6Mm Dia @ 150C / C Both Ways And Pit / Chamber In Pcc 1:3:6 Type C1 With Suitable Lifting Handle To Cover, Gi Protection Pipe 25Mm Dia Light Grade Up To 7.5M From Complete All As Specified, Including On Electrical Plate No 5 And As Directed Including Testing On Completion. Note: ( I ) Earthing Will Be Strictly As Per Specifications Contained In Standard Schedule Of Rates Of Mes Part I ( Ii ) On Testing After Completion If Desired Earth Resistance Is Not Obtained, The Earthing Will Not Be Measured For Payment To The Contractor. 78 S&F 09W / 10W Bulk Head Liminiares Including Led Light Driver Holder Connectingup With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed. 79 Supply And Fix Led Lamp 7 Watt Complete All As Specified And Directed. 80 Supply, Laying , Jointing And Testing Lt Underground Cable, Heavy Duty, 1100 Volts, Xlpe Insulated And Sheathed, Armoured With Multi-Stranded Aluminium Conductor Cable Isi Marked, Laid In Trenches / Ducts Or Fixed To Poles / Walls Or Laid Under Roads / Paths / Drains / Culverts Duly Encased In Galvanised Steel Pipe Of Suitable Sizes 16 Sqmm2.0 Core Including Cable Gland Of Suitable Sizesand Aluminium Lugs For Connection Complete All As Specified And Directed 81 Supply And Laying Dry River Sand For Cable Cushioning In Trenches To Required Width At Bottom And Top Of Cable Including Spreading Levelling Watering And Consolidation Complete All As Specified And Directed By Engineer-In-Chargenote:-Punned Thickness Only Shall Be Measured And Paid. 82 Supply And Laying Old Size Brick Covering With Width Equal To Length Of Brick As The Mechanical Protection To Cable With Well Burnt Sub Class B Laid In Trenches Flat Complete All As Specified And Directed By Engineer-In-Charge. 83 Supplying And Fixing , 50 Mm Borelight Grade Isi Marked , Galvanised Mild Steel Pipe / Tubing, Complete With All Fittings, Laid Under Roads, Drain, Paths, Fixed To Poles / Walls With Suitablemild Steel Clamps , Bolts , Nuts And Washers Complete All As Specified And Directed As For Cable Proction Of Following Sizes:-. ( Note:- Excavation & Earth Work Shall Be Measured And Paidfor Separately Under Appropriate Item Of This Schedule ) :-

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-01-2024
2 22-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-01-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 110840.0 /-
Tender Value
INR 57.22 Lakhs /-

BOQ Items

Name of Work: PROVN OF STORAGE ACCN FOR ECC & E COL INCL SCME STORES AT HAWS GULMARG UNDER GE 969 EWS.
Sl. No. Item Description
1Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose of soil complete all as specified and` directed.
2Excavation in trenches n.exc 1.50m wide and n. exc 1.50m in depth and getting out in soft/loose of soil complete all as specified and` directed.
3Excavation in trenches n.exc 1.50m wide and n. exc 1.50m in depth and getting out in hard/dense of soil complete all as specified and` directed.
4Excavating over areas, n exc 1.5m deep and getting out in hard/dense soil, complete all as specified and` directed.
5Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and` directed.
6Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and` directed.
7M&L PCC type C2 1:3:6 (40mm graded aggregate ) in foundations, filling and mass Concrete complete all as specified and` directed.
8M&L PCC type D2 1:4:8 (40mm graded aggregate ) in foundations, filling and mass Concrete complete all as specified and` directed.
9M&L 75mm thick PCC type E2 1:5:10 (40mm graded aggregate ) in foundations, filling and mass Concrete complete all as specified and` directed.
10M&L Random rubble masonry built in cement Mortar 1:4 uncoursed, well bonded, bedded and solidly hearted complete all as specified and` directed.
11M&L for Shingle filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled, and blinded with earth and rammed including watering complete all as specified and` directed.
12M&L Brick work with sub class "B" bricks, straight or curved on plan exc. 6m mean radius built in CM 1:4 complete all as specified and` directed.
13Extra over stone walling for hammer dressing on face from straight edge held against the dressed surface n exc. 40mm to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses for Granite ot Trap complete all as specified and` directed.
14Flush pointing in cement mortar 1:4to random rubble masonry, uncoursed or brought upto courses complete all as specified and` directed.
15M&L for boulder filling dry Hand packed (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and` directed.
16M&L Brick work with sub class "B" bricks, straight or curved on plan radius in half brick thick walls built in CM 1:4 complete all as specified and` directed.
17M&L for PCC 1:2:4 type B-0 (12.5mm graded aggregate) as in coping,plinth band ,bed block including rounded or chamfered angle as directed including necessary formwork etc complete all as specified and` directed.
18Material and labour for plain cement concrete 1:2:4 type B-1 (using 20mm graded mechanically crushed stone aggregate) as in surface channels and drains, complete all as specified and ditected.
19M&L Mild steel TMT bars 10mm dia and over, cut to length bent to shap required including cranking, bending spirally for hooping for columnshooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or secur;ing with clips quality conforming to FE-410-s or FE 410-0 complete all as specified and` directed.
20Ditto as per itemNo 18 above but8 mm dia bars as in stirrups/ spacers complete all as specified and directed.
21M&L Rendering 10mm thick plaster on internal face of wallin CM 1:6 finished even and smooth without using extra cement complete all as specified and` directed.
22M&L Rendering 15mm thick plaster on stone/brick masonary surface or other than fair faces of brick work in cement mortar 1:4finished even and smooth without using extra cement complete all as specified and` directed.
23M&L Rendering 15mm thick plaster on stone/brick masonary surface or other than fair faces of brick work in cement mortar 1:4 mixed with water proofing compound complete all as specified and` directed. Note: WPC shall be measured and paid separately.
24Supply only liquid water proofing compound ISI Marked complete all as specified and directed.
25Supply and fixing pressed steel doors frames of size 105 mm x 60 mm with one or more rebates including fixing necessary lugs,3 Nos 100 mm long hinges per shutter ,lock strike plate etc. including making good the disturbed portion to match with existing complete all as specified and directed.
26S&F prepainted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screwincluding necessary scaffolding, anytype, any location/height complete all as specified anddirected by Engr-in-Charge.
27S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including necessary scaffolding, anytype, any location/ height complete all as specified anddirected by Engr-in-Charge.
28S&F factory made box type steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete all as specified anddirected by Engr-in-Charge.
29Supply and fixing factory made Box type steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing barscomplete all as specified.
30M&L Preparation of newly plaster surface andapplyingtwo coat of cement base paint over a coat of primercomplete all as specified and` directed.
31M&L Preparation of newly plaster surface andapplying two coat of oil bond distemper over one coat of putty complete all as specified and` directed.
32Material and labour for plain cement concrete 1:3:6 type C1 using 20 mm graded mechanically crushedstone aggregate as in cills, steps, copings, bed plates, kerbs, hold fasts blocks etc including weathering slightly rounded or chamfered angles of throating includingnecessary form work to concrete surfaces complete all as specified and directed.
33Preparing surfaces of new steel and iron work of any description and girth, not otherwise described, and treated with tar or coal tar black painttreating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area n exc 0.1 sq. m each complete all as specified and directed.
34S&F FI 25X3mm for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and` directed.
35Supply and fixing mild steel section such as in roof truss, rails, purlin as in framed work for roof covering including all flange, cutting, welding, drilling holes for screws including distance pieces and cleats etc complete all as specified and conforming to Fe 410-0 W (Gde-E-250) quality-A complete all as specified.
36Material and labour for preparation of newly steel and iron surfaces of any description not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and` directed.
37Material and labour for preparation of new or previosly untreated wood and wood based surfaces of any description not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of pink primer primer complete all as specified and` directed.
38M&L Aluminium, anodised, barrel tower bolts of extruded section and fixed 150 mm ISI Marked complete all as specified and` directed.
39M&L Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm ISI Marked complete all as specified and directed.
40M&L Aluminium Oval type handles, cast type, anodised 150mm complete all as specified and directed.
41S&F sheet glass 4 mm thick, Figured glass, pin head type and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and directed.
42S&F factory made 35mm thick second class soft wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
43M&L Hardcore of gaugeexc. 63mm but not exc 100mm, deposited, spread and levelled in layers n exc. 150mm thick, watered and rammed to a true surface complete all as specified and` directed.
44M&L for 25mm thick PCC 1:2:4 type B1 (using 20mm graded crushed stone agg) as in sub base & floor base complete all as specified and directed.
45M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone agg) as in sub base & floor base complete all as specified and directed.
46Supply andfixingPCC coloured , rubber moulded , interlocking designer paver blocks( double glossy)in any and shape, confirming to IS-15658-2006 of 60mm thickness, M-35 gradein path, hard standing, etc. laid over and including 50 mm thick screed or bedding layer of sand, complete all as specified.
47M & L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and` directed.
48Material andlabour for plain cement concrete, 1:2:4 type B-1 (using 20 mm graded mechanical crushed aggregate) for levelling course, benching, coving, roof kerbs mixed with acrylic bases polymer water proofing compound, complete all as specified anddirected .Note- Supply only acrylic based polymer water proofing compoundshall be measured and paid for separately.
49M&L Damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick in cement concrete 1:2:4 type-B-0 using 12.5mm graded stone aggregate complete all as specified and directed.
50M&L 25 mm thick PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate ) as in plinth protection, surfaces finished even and fair, complete all as specified and directed.
51Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed.
52Material and labour for machine cut Kota stone slab 20-25mm thickas in flooring, laid over and including cement screed bed 20 mm thick in cement mortar 1:3, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polishing complete all as specified.
53M&L forMachine cut kota stone slab flooring 12-15 mm thick as on vertical surfaces such as skirting /dadosover 10 mm rendering in CM 1:3 height of skirting 100 mm and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polishing complete all as specified and directed.
54M&L for 110mm dia PVC (SWR) pipes ISI Marked single socketed in any length with rubber ring joints as in weep holes etc complete all as specified and` directed.
55M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticle or to batter withrough finish flat surface complete all as specified and directed.
56M&L for form work to sides of pillars,posts, struts, pears, columns & stanchion square or rectangularor polygonal etc with rough finished surface of concrete complete all as specified and as directed.
57M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvves including sup-ports, overhangs, etc. also splays between floors and beams, etc finish withrough finish flat surface complete all as specified and directed.
58M&L RCC M-30 (Design mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete completet all as specified and directed.
59M&L RCC M-30 (Design mix) as in Columns, pillars, piers, posts and struts completet all as specified and directed.
60M&L RCC M-30 (Design mix) as in Beams, cantilevers, bressummers, lintels over 1.5m span completet all as specified and directed.
61M&L for RCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for inclduing necessary form workcomplete all as specified.
62Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over seamless ceiling fillets or metal frame work and reinforced with G.I. wire mesh complete all as specified.
63Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
64M&L Precast cement concrete B1 type, (1:2:4) using 20 mm graded aggregate set in cement moertar 1:6 in bond stones for stone masonary and the like including necessary formworketc complete all as per specified and directed.
65Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLS insulated un-sheathed copper conductor single core multi stranded flexible cable (green color) as earth lead in and including cable 1100 volts grade including PVC casing and capping/conduit(ISI marked) for one light/ fan point including 2nd class hard wood rectangular block open recessed cover with 3mm thick plastic laminated sheet cover including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specified.
66All as per item No 65 herein before but wiring with 2.5 sqmm copper wire ( FRLS)and 2.5 sqmm earth wire for socket outlet 3 pin 5 amps on same board complete all as specified and` directed.
67All as per item No 65 herein before but wiring with 1.5 sqmm copper wire ( FRLS)and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on independent board complete all as specified and` directed.
68S&Fswitch piano flush button single pole, one way 6 amps 240 Volts including taking down complete all as specified and directed.
69S & F switchsocket combination 2 in 1, 3 pin 5A, flush type universal complete all as specified and directed .
70S & F switchsocket combination 2 in 1, 3 pin 15A, flush type universal complete all as specified and directed .
71S&F of distribution board single pole & neutral with 200 Amps rated bus bar,for double door IP-42 DB"s ,made outof sheet steel enclosure, recessed type, factory made powder coated 8 way -415 volts suitable for housing MCB"s and isolator"s complete in all fixing material/accessories etc complete all as specified and directed.
72S&F MCB"s single pole 240 volts 6 to 32Amps 10 KA "B"curve series, all as specified and as directed by Engr -in-Charge.
73S&F MCB"s single pole 240 volts 40 to 63Amps 10 KA "C"curve series, all as specified and as directed by Engr -in-Charge.
74M & L in repairLamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed
75S&F LED, 20 Watts, 4 ft, 220V AC fittings decorative box type with driver complete with all accesories for mounting light fittings complete with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed.
76Supply and fixing ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed.
77Material and labour for earthing complete with galvanised steel, earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.65 mtrs below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 5 on page 19-49 of MES schedule 1991 Part I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all-round the GI earth plate, watering pipe 20mm dia GI medium grade.GI sheet 0.63mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150C/C both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 25mm dia light grade up to 7.5m from complete all as specified, including on electrical plate No 5 and as directed including testing on completion. NOTE: (i)Earthing will be strictly as per specifications contained in Standard Schedule of Rates of MES Part I (ii)On testing after completion if desired earth resistance is not obtained, the earthing will not be measured for payment to the contractor.
78S&F 09W/10W Bulk head liminiares including LED light driver holder connectingup with three core flexible copper conductor cable of suitable size complete all as specified and directed.
79Supply and fix LED Lamp 7 Watt complete all as specified and directed.
80Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable ISI Marked, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes 16 sqmm2.0 core including cable gland of suitable sizesand aluminium lugs for connection complete all as specified and directed
81Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed by Engineer-in-chargeNote:-Punned thickness only shall be measured and paid.
82Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class "B" laid in trenches flat complete all as specified and directed by Engineer-in-charge.
83Supplying and fixing ,50 mm borelight grade ISI Marked , Galvanised mild steel pipe / tubing, complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitablemild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable proction of following sizes:-.(Note:- Excavation & earth work shall be measured and paidfor separately under appropriate item of this schedule ):-
Disclaimer :