Tender For Misc. Works For Restoration Of Various Areas Damaged By Fire Incident At C Block & Adjoining Areas, Nehru Hospital, Pgimer, Chandigarh (Sh: Restoration Of Fire Alarm System)., Chandigarh-Chandigarh

Post Graduate Institute Of Medical Education And Research-PGIMER has published Tender For Misc. Works For Restoration Of Various Areas Damaged By Fire Incident At C Block & Adjoining Areas, Nehru Hospital, Pgimer, Chandigarh (Sh: Restoration Of Fire Alarm System).. Submission Date for this Tender is 08-01-2024. Building Work Tenders in Chandigarh Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

41399690
Tender For Misc. Works For Restoration Of Various Areas Damaged By Fire Incident At C Block & Adjoining Areas, Nehru Hospital, Pgimer, Chandigarh (Sh: Restoration Of Fire Alarm System).
Open Tender
Indian
Chandigarh
Chandigarh
08-01-2024

Tender Details

Tender For Misc. Works For Restoration Of Various Areas Damaged By Fire Incident At C Block & Adjoining Areas, Nehru Hospital, Pgimer, Chandigarh ( Sh: Restoration Of Fire Alarm System ) .; 1 Supplying, Installation, Testing And Commissioning Of Micro Processorbasedintelligentaddressablemainfirealarm Panel, Centralprocessingunitwiththefollowingloop Modules And Capable Of Supporting Not Less Than 240 Devices ( Including Detectors ) And Minimum 120 Detectors Per Loop And Loop Length Up To 2 Km, Network Communication Card, Minimum 320 Character Graphics / Lcd Display With Touch Screen Or Other Keypad And Minimum 4000 Events History Log In The Non Volatile Memory ( Eprom ) / Gui, Power Supply Unit ( 230 ± 5%V, 50Hz ) , 48Hrsback-Upwith 24Voltsealed Maintenancefreebatterieswithautomaticcharger. 2 The Panel Shall Have Facility To Connect Printer To Printout Log And Facility To Have Seamless Integration With Analog / Digital Voice Evacuation System ( Which Is Part Of The Schedule Of Work Undersh:Pasystem ) , The Panel Should Have Integrated / Saparate Fire Fighting Telephone Controller For Fire Fighter Telephone System Andshallbecompletewithall Accessories . The Panel Shall Be Compatible For Ibms System With Open Protocol Bacnet / Modbus Over Ip Complete As Per Specifications 3 Ten Dual Loop Card Panel 4 Supplying, Installation, Testing And Commissioning Of Micro Processor Based Intelligent Addressable Asu / Ft Two Way Communication System With Audio & Talkback Unit With 2 Nos. Digital Audio Amplifier75 W, The Unit Should Have Eight Channels For Audio Selection, Voice Command Keypad 6 Zone, With Microphone Assembly , Vu Display Shows Paging Output Level, On Board Storage Of Programmed Messages And Tones, Lcd Display Of Fire Phone Calls Complete Withall Accessories With Main Fire Alarm Panel As Required To The Satisfaction Of Engineer In-Charge 5 Supplying, Installation, Testing & Commissioning Of Addressable Monitor Module Complete As Required 6 Supplying, Installation, Testing & Commissioning Of Intelligent Analog Addressable Photothermal Detector Complete With Mounting Base Complete As Required. 7 Supplying, Installation, Testing & Commissioning Of Fault Isolator Complete With Base As Required. 8 Supplying, Installation, Testing & Commissioning Of Intelligent Addressable Thermal Detector With Rate Of Rise Cum Fixed Temperature Thermistor Complete With Base As Required. 9 Supplying, Installation, Testing & Commissioning Of Addressable Fire Control / Relay Module Complete As Required. 10 Supplying, Installation, Testing & Commissioning Of Addressable Phone Control Module With Jack Plate Complete As Required. 11 Supplying, Installation, Testing & Commissioning Of Fire Fighter Telephone Handset Complete As Required 12 Supplying, Installation, Testing & Commissioning Of Addressable Manual Call Point Complete As Required. 13 Supplying, Installation, Testing & Commissioning Of Response Indicator On Surface / Recessed Ms Box Having Two Led, Metallic Cover Complete With All Connections Etc As Required. 14 Supplying, Installation, Testing & Commissioning Of Addressable Horn Cum Strobe Complete As Required. 15 Supplying & Laying Of 2X1.5 Sqmm Fire Survival Armoured Cable, 600 / 1000V Rated With Annealed Copper Conductor Having Glass Mica Fire Barrier Tape Covered By An Extruded Layer Of Cross Linkable Ethylene Propylene Rubber ( Epr ) Insulation And Lszh Inner Bedding, Steel Wire Armouring & Lszh Outer Sheath Complete As Required. 16 Supplying, Installation, Testing & Commissioning Of Intelligent Addressable Duct Detector Including Suitable Photo Detector Complete With Base As Required 17 Supplying, Installation, Testing & Commissioning Of 1.5 / 3 / 6W Metal Box Body Ceiling / Wall Speakers Complete As Required. 18 Supplying & Fixing In Position Ms Anodised Box Colour Caoted For Installation Of Detectors On True Ceiling Complete As Required. 19 Sitc Of Clean Agentnovec 1230 Based Gas Fire Suppression System Suitable Upto 2 Cum Volume. The Clean Agent With Zero Odp As Per Nfpa 2001, Ul Listed, With Container Bs En3-8, Electrical Non Conductive Clean Agent, Capacity 2 Kg. The System Comprisinging Of Heat Sensing Tube ( Hst ) Made Of Polyamide ( Ul / Lpcb Listed ) , Size Of Tube 4Mm Id And 6Mm Od, The Hst To Be Pressurised With Dry Nitrogen Gas Confirming Is:1747 With Quantity As Per Requirermemt At Site And Connected To An Extinguishing Agent Container Via Adirect Low Pneumatic Pressure Relesevalve Havingtwo Nos Outlets , Inbuilt Pressure Gauge , Integrated Ball Valve For Open / Close With In The Valve Body. System To Have Audio-Video Monitoring Panel, Microprocessor Based To Check The Health Of System And Pressure In The Tube With Indication Of Ac Power On, System Discharge, Valve Open / Closed, Pressure Heal;Thy, Battery Low, Etc. System To Have Power Pack Having 12V 7 Ah 2 Nos Smf Battery With Piezo Electric Buzzer 50 Db. System Should Have Third Party Integration Facility With Existing Fire Alarm System, Job Complete With Elbow, Connectors, Ts, End Of Line Adapter And End Of Line Plug In Hst Tube As Required. Max Working Pressure Is 20 Bar, Burst Pressure At 20 Degreec: 110 Deg.C, System Operating Pressure Is 15 Bar. System To Be Lpcb Standard Lps 1666:Issue 1.0 20 Add Gst @ 6% ( Mf@ 0.633 ) 21 Rebate For Old Detectors & Other Fire Alarm Components

Key Value

Document Fees
Refer document
EMD
INR 179660.0 /-
Tender Value
INR 89.83 Lakhs /-