| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge (Item Code HPPWDSR 2020 - Chapter 15.2) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix): (Item Code HPPWDSR 2020 - Chapter 15.2.1) |
| 2 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.(Item Code HPSR 2020 - Chapter 2.9)Ordinary Rock : (Item Code HPSR 2020 - Chapter 2.9.1) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (Item Code HPPWDSR 2020 - Chapter 2.8)All Kinds of soil : (Item Code HPPWDSR 2020 - Chapter 2.8.1) |
| 4 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth,including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. (Item Code HPPWDSR 2020 - Chapter 2.10)Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia.(Item Code HPPWDSR 2020 - Chapter 2.10.1.2) All Kinds of Soil |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 6 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.(Item Code HPPWDSR 2020 - Chapter 5.9.2) |
| 7 | Foundations, footings, bases for columns (Item Code HPPWDSR 2020 - Chapter 4.3.1) |
| 8 | Extra Allowance for formwork in concrete lining. |
| 9 | In Bed |
| 10 | In Side Slope |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) complete in all respect within all leads and lifts and to the entire satisfaction of theEngineer-in-Charge. |
| 12 | Providing and laying in position cement concrete 1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of theEngineer-in-Charge. |
| 13 | All work up to plinth level excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of theEngineer-in-Charge. |
| 14 | Providing and laying in positionreinforced cement concrete 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) and curing complete in : |
| 15 | All work up to plinth level excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of theEngineer-in-Charge. |
| 16 | In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of theEngineer-in-Charge. |
| 17 | Providing cement concrete lining 15 cm thick or less for irrigation channels, using cement concrete 1:2:4 (1 cement2 sand :4 stone aggregate 20 mm nominal size) in: |
| 18 | Bed complete in all respect within all leads and lifts and to the entire satisfaction of theEngineer-in-Charge. |
| 19 | Side slopes complete in all respect within all leads and lifts and to the entire satisfaction of theEngineer-in-Charge. |
| 20 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.(Item Code HPPWDSR 2020 - Chapter 11.3) |
| 21 | Providing Mild steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete in all respect within all leads and lifts and to the entire satisfaction of theEngineer-in-Charge. |
| 22 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(Item Code HPPWDSR 2020 - Chapter 10.2) |
| 23 | Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS:16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12(D=100 mm with tolerance of ± 2%) Zinic+PVC coated, Mesh wire diameter 2.7/3.7mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per directions of Engineer-in-charge.(Item Code HPPWDSR 2020-Chapter 16.94) |
| 24 | Providing, laying, jointing, commissioning & testing in trenchesHDPE pipesof following diameters & classes as per IS 4984 (1995) and jointing the pipes with push type compression joints byhydraulically operated machines, butt fussion welding & electro fusion welding machines i/c necessary fittings, bends, tees, unions, flanges, collars & reducersetc. confirming to IS 8360 & IS 8008with latest ammendments& shall be provided as per site conditions. Flanging of the pipes shall be made as & where required. Jointing shall be confirming to IS code 8008 & IS 7634, stub ends will be welded on pipes & MS flange shall be provided with slip on covered by epoxy coating/plastic powder. The flange should be confirm to ANSI B 16.5 with necessary nuts & bolts.All manufacturing maerial used shall be in accordance to IS 4427-2007 (latest revision) with 100 % virigin pre-compounded or natural PE resin. Jointing shall be complete in all respects i/c testing at site upto entire satisfaction of theEngineer-in-Charge. |
| 25 | HDPE Pipe 125 mm ? (PN. 6.0, PE. 100) |
| 26 | Providing, laying, jointing and testing in trenches (to level or grade) GMS tube ( IS : 1239-2004) of 150 mm dia, & medium Class conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge. (EARTH WORK IN TRENCHES TO BE MEASURED PAID FOR SEPARATELY) |
| 27 | Providing and fixing CI Sluice Valve of following dia & class of Leader / Kartar / Kirloskar make with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of theEngineer-in-Charge. |
| 28 | 150 mm dia,PN-1.0 (10.2 Kg/cm²) |
| 29 | 125 mm dia,PN-1.0 (10.2 Kg/cm²) |
| 30 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete(Item code HPPWDSR2020- Chapter 9.66)125 mm. (Item code HPPWDSR2020 Chapter-9.66.1) |
| 31 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. (Item Code HPPWDSR2020-Chapter 13.52.1) On Steel Work |
| 32 | Printing new lettters and figures of any shade with synthetic enamel black or any other approved colour to give n even shade as per drawings and technical specifications clause 1701 in English and roman, hyphen, commas and the like not to be measured and paid for |
| 33 | Providing & fixing Length of 75 mm ? HDPE Riser Double Threaded(PN. 6.0, PE. 80) . |
| 34 | Providing & Fixing 75 mm PP Ball Valve including all necessary fittings |