| Sl. No. | Item Description |
| 1 | NOTE (Applicable for all Parts/ Items):-The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | SCHEDULE \"A\" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced Schedule is given in tender documents |
| 3 | SCHEDULE \"A\" PART-II (EARTH WORK AND SITE CLEARANCE) Details of pre-priced Schedule is given in tender documents |
| 4 | SCHEDULE \"A\" PART-III (INTERNAL ELECTRIFICATION) Details of pre-priced Schedule is given in tender documents. |
| 5 | SCHEDULE \"A\" PART-IV (INTERNAL WATER SUPPLY)Details of pre-priced Schedule is given in tender documents. |
| 6 | SCHEDULE \"A\" PART-V (ROAD/FOOT PATH/SLAB CULVERT)Details of pre-priced Schedule is given in tender documents. |
| 7 | SCHEDULE \"A\" PART-VI (AREA DRAINAGE)Details of pre-priced Schedule is given in tender documents. |
| 8 | SCHEDULE \"A\" PART-VII (SEWAGE DISPOSAL)Details of pre-priced Schedule is given in tender documents. |
| 9 | SCHEDULE \"A\" PART-VIII (EXTERNAL WATER SUPPLY)Details of pre-priced Schedule is given in tender documents |
| 10 | SCHEDULE \"A\" PART-IX (EXTERNAL ELECTRIFICATION)Details of pre-priced Schedule is given in tender documents |
| 11 | SCHEDULE \"A\" PART-X (STREET/SECURITY LIGHT)Details of pre-priced Schedule is given in tender documents |
| 12 | SCHEDULE \"A\" PART-XI (LIGHTENING PROTECTION)Details of pre-priced Schedule is given in tender documents |
| 13 | SCHEDULE \"A\" PART-XII (DEMOLITION/DISMANTLING)Details of pre-priced Schedule is given in tender documents |
| 14 | SCHEDULE \"A\" PART -XIII (MISCELLANEOUS ITEMS)Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.\" F \" signifies this fact only. |
| 15 | INTERNAL ELECTRIFICATION.S&F Ultra bright LED 24W polycarbonate Tubelight with THD<10% with very high efficacy suited for installation in surface and wall mounted LED batten with Aluminum housing & integrated electronic driver with required accessories, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . |
| 16 | S&F Ultra bright LED 20W polycarbonate Tubelight with THD<10% with very high efficacy suited for installation in surface and wall mounted LED batten with Aluminum housing & integrated electronic driver with required accessories, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . |
| 17 | S&F Ultra bright LED 18W polycarbonate Tubelight with THD<10% with very high efficacy suited for installation in surface and wall mounted LED batten with Aluminum housing & integrated electronic driver with required accessories, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . |
| 18 | S&F Ultra bright LED 10W polycarbonate Tubelight with THD<10% with very high efficacy suited for installation in surface and wall mounted LED batten with Aluminum housing & integrated electronic driver with required accessories, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . |
| 19 | S&F Ultra bright LED 9W Tubelight with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in existing T5 fitting with G5 lamp holders, LED driver outside with surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and required accessories, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . |
| 20 | S&F High output NU Bulb Plus 9 W -865-B22, 3 Star specialized high wattage lamps and decorative LED Filament lamps for all household and commercial needs with required accessories complete all as specified and directed . |
| 21 | S&F LED 9W Surface mounted downlight with white powder coated polycarbonate decorative housing and pressure die-cast heat sink having high efficiency with heavy duty driver having THD<10%. with required accessories, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . |
| 22 | S&F surface mounting LED 15W Light fixture which provides soft-light and glare free symmetrical illumination with required accessories,connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . |
| 23 | S&F LED Bulkhead 10W Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit LED luminaire comprising of high brightness LEDs. with required accessories, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . |
| 24 | S&Fenergy saving and environmental friendly long life 20WLED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK-07 wth required accessories connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . |
| 25 | S&F recess mounting luminaire (2\" x 2\") 36 watt with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, CRCA powder coated,integrated high efficiency electronic driver with lower THD (< 20 %) , IP 20, CRI >=80, Colour Temp (CCT)- 6500 K, System lumen not less than 4350 lm. Electronic driver & surge suppressor, power factor0.95, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including 01 No. 10 W (2 FT) LED lamp or strip high efficiency LEDs as per OEM with viewing angle of 120º with certification LM 79 for luminare, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twintwisted flexible copper conductor cable of suitable size ceiling rose to terminal blockcomplete all as specified and directed . |
| 26 | S&F recess mounting luminaire 15 Watts square with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, CRCA powder coated,integrated high efficiency electronic driver with lower THD (< 20 %), Colour Temp (CCT)- 6500 K,Electronic driver & surge suppressor, power factor0.90, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including high efficiency LEDs as per OEM with certification LM 79 for luminare, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twintwisted flexible copper conductor cable of suitable size ceiling rose to terminal blockcomplete all as specified and directed . |
| 27 | S&F recess mounting luminaire 12 Watts squarewith high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, CRCA powder coated,integrated high efficiency electronic driver with lower THD (< 20 %), Colour Temp (CCT)- 6500 K,Electronic driver & surge suppressor, power factor0.90, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including high efficiency LEDs as per OEM with certification LM 79 for luminare, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twintwisted flexible copper conductor cable of suitable size ceiling rose to terminal block complete all as specified and directed . |
| 28 | S&F recess mounting luminaire 9 Watts square with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, CRCA powder coated,integrated high efficiency electronic driver with lower THD (< 20 %), Colour Temp (CCT)- 5700 K,Electronic driver & surge suppressor, power factor0.90, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including high efficiency LEDs as per OEM with certification LM 79 for luminare, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twintwisted flexible copper conductor cable of suitable size ceiling rose to terminal block complete all as specified and directed . |
| 29 | S&Fstreet light fittings bracketmade out of 1.0 meter long 40 mm boreGI pipe, light grade,bent to required shape and fixing to building including flat iron clamp of size 40mm x 6 mm fixed with bolts and nutswith washer of suitable size/length as required duly grouted in wall including two coats of aluminum paint over a coat ofprimer complete all as specified and directed . |
| 30 | S&F Energy efficient five star rated ceiling fan 230 volts, single phase AC, 1200 mm sweep, BEE 5 star rated, Brushless Direct Current(BLDC) without remote type with accessories like holding down rod,hanging clamps, blades, fan hook including writing MES number (as per standard practice)including provision of three core flexible copper wire ofsuitable sizefrom ceiling rose to ceiling fancomplete in all respect all as specified and directed. |
| 31 | S&Fexhaust fan metallic steel body, single phase, 230 volts, 50 Hzs of size 300mm sweep, 900/950 RPM,heavy duty type with suitable metallic louver, blades, frameand flexible three core copper conductor cable of suitable size for connecting with ceiling rose completeall as specified and as directed. |
| 32 | S&Fexhaust fan with louvers 200 mm sweep , AC single phase 240 volts, 50Hz and connecting up complete including built in louvers and provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fancomplete all as specified and as directed. |
| 33 | M&L forconcealed sub main wiringsubmain wiring for main DBs to Sub DBs/Plug & Sockets with PVC insulated unsheathed FR-LSH cable 1100 volts grade of size 2.5 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 1.5 Sq mm x 1 run, ISI markedmulti stranded copper conductor single core cable drawn in and includingnon-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm as requried as specified and as directed.Note:- (a)Two runs of 2.5sqmm conductor for main and one run of 1.5 sqmm conductor as earth wire with PVC conduitshall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c)Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles. |
| 34 | M&L forconcealed sub main wiringsubmain wiring for main DBs to Sub DBs/Plug & Sockets with PVC insulated unsheathed FR-LSH cable 1100 volts grade of size 4 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 2.5 Sq mm x 1 run, ISI markedmulti stranded copper conductor single core cable drawn in and includingnon-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm all as requried as specified and as directed.Note:- (a)Two runs of 4 sqmm conductor for main and one run of 2.5 sqmm conductor as earth wire with PVC conduitshall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c)Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles. |
| 35 | M&L forconcealed sub main wiringsubmain wiring for main DBs to Sub DBs with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 6 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 4 Sq mm x 1 run, ISI markedmulti stranded copper conductor single core cable drawn in and includingnon-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm as requried all as specified and as directed.Note:- (a)Two runs of 6 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with PVC conduitshall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c)Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles. |
| 36 | M&L forconcealed sub main wiringsubmain wiring for main DBs to Sub DBs with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 10 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 6 Sq mm x 1 run, ISI markedmulti stranded copper conductor single core cable drawn in and includingnon-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm as requried all as specified and as directed.Note:- (a)Two runs of 10 sqmm conductor for main and one run of 6sqmm conductor as earth wire with PVC conduitshall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c)Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles. |
| 37 | M&L forconcealed submain wiringwith PVC insulated unsheathed FR-LScable 1100 volts grade of size 6 Sqmm x 4 run alongwith earth continuity wire connected from main earth of size 4 Sq mm x 2 run, ISI markedmulti stranded copper conductor single core cable drawn in and includingnon-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 40 mm as requried all as specified and as directed.Note:- (a)Four runs of 6 sqmm conductor for main and Two runs of 4 sqmm conductor as earth wire with PVC conduitshall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c)Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles. |
| 38 | M&L forconcealed submain wiringwith PVC insulated unsheathed FR-LScable 1100 volts grade of size 10 Sqmm x 4 run alongwith earth continuity wire connected from main earth of size 6 Sq mm x 2 run, ISI markedmulti stranded copper conductor single core cable drawn in and includingnon-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 40 mm as requried all as specified and as directed.Note:- (a)Four runs of 10 sqmm conductor for main and Two runs of 6 sqmm conductor as earth wire with PVC conduitshall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c)Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles. |
| 39 | M&L forconcealed submain wiringwith PVC insulated unsheathed FR-LScable 1100 volts grade of size 16 Sqmm x 4 run alongwith earth continuity wire connected from main earth of size 10 Sq mm x 2 run, ISI markedmulti stranded copper conductor single core cable drawn in and includingnon-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 40 mm as requried all as specified and as directed.Note:- (a)Four runs of 16 sqmm conductor for main and Two runs of 10 sqmm conductor as earth wire with PVC conduitshall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c)Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles. |
| 40 | M&L for Sheet metal enclosure MCB DB, 6 way, SPN, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder coated including earthing etc. as required.complete all as specified and directed. |
| 41 | M&L for Sheet metal enclosure MCB DB double door, 4 way , IP-43, TPN with 200 amps rated bus bar, IP-20 protection, including four pole MCCB 63 Amps with blanking platescomplete all as specified and directed. |
| 42 | M&L for 4 way surface/ recess mounting, vertical type, 415 V, TPN MCCB DB of sheet steel, dust protected, duly powder coated,tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required completeall as specified and directed. |
| 43 | S&F MCCB four pole, 32 Amps, 16 kA breaking capacity with thermal magnetic releasecomplete all as specified and directed. |
| 44 | S&F MCB TP 32Amps (C-Curve), breaking capacity 10 kA, 415 voltscomplete all as specified and directed. |
| 45 | S&F MCB TPN 32Amps (C-Curve), breaking capacity 10 kA, 415 voltscomplete all as specified and directed. |
| 46 | S&F MCB 4P32Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed. |
| 47 | S&F MCB 4P40Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed. |
| 48 | S&F MCB 4P63Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed. |
| 49 | S&F MCB Double Pole40Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed. |
| 50 | S&F MCB Double Pole32Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed. |
| 51 | S&F MCB SPN6-32Amps (C-Curve), breaking capacity 10 kA, 240 volts with cable connection and copper lugsing complete all as specified and directed. |
| 52 | S&F MCB SP 6 to 32Amps (C-Curve), breaking capacity 10 kA, 240 volts with cable connection and copper luging complete all as specified and directed. |
| 53 | S&F blanking Plate to coversuitable for MCB DB complete all as specified and as directed. |
| 54 | S&F modular Telephone socket with modular plate and switch box including connections including modular plate etc as required complete all as specified and directed. |
| 55 | S&F modular TV socket with modular plate and switch box including connections including modular plate etc as required complete all as specified and directed. |
| 56 | Supplying and drawing Two pair 0.4 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed. |
| 57 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed. |
| 58 | Supplying and drawing PVC Insulated with RG-59 Co-axial cable copper conductor and PVC outer Sheathed CCTV Camera Cable in the existing surface/ recessed Steel/ PVC conduit as required complete all as specified and directed. |
| 59 | Supply, installation, testing and commissioning of 4U, wall/floor Mountable powder coated Rack with Cable Manager, Power Manager, with Power Distribution Unit, fan, minimum 3 Nos of shelves, Front Glass door with Lock andkey complete all as specified and directed. |
| 60 | Supply, installation, testing and commissioning of 2U, wall/floor Mountable powder coted Rack with Cable Manager, Power Manager, with Power Distribution Unit, fan, min 3 nos of shelf, Front Glass door with Lock & key complete all as specified and directed. |
| 61 | Supply, installation, testing and commissioning of 16 PORT 10/100/1000 GIGABIT 16 PORT gigabit switchwith 4 SFP SLOT complete all as specified and directed. |
| 62 | Supply, installation, testing and commissioning of 8 PORT 10/100/1000 GIGABIT 8 PORT gigabit switchwith 4 SFP SLOT complete all as specified and directed. |
| 63 | Supply, installation, testing and commissioning of 16 Port Patch Panel completeall as specified and directed. |
| 64 | Supply, installation, testing and commissioning of 8 Port Patch Panel completeall as specified and directed. |
| 65 | S & F MDF Telephone Krone DB 50 way in a thermoplastic, enclosure, on wall including cutting, drilling, making hole on wall including cutting of brick work, fixing with cement sand mortar, including finishing the surface with existing finishes completeall as specified and directed. |
| 66 | S&F electric water heater storage type acrylic/ABSbody with stainless steel inner tank and heating element upto 1.5/2 KW capacity 25 litre, vertical type BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, includingPVC connectionpipe for hot/ cold water to existing water lines,necessary fixing arrangementby using 50 X 5 mm MS plateand writing MES No and paste the instruction sheet of Do’s and DO NOTcomplete all as specified and as directed. |
| 67 | Supply, installation, testing & commissioning of Single Phase, two wire, tamper proof Smart Prepaid Meter, System WAN Communication based, AC Single Phase, Two wire, 240 V AC, 50 Hz, current rating 5-60 Amps or 10-60 Amps having accuracy class 1.0 with Single phase Hot pressed SMC meter box of minimum size 250x250x160mm or as suitable with viewing glass, concealed hinge and earth bolt plugged completed , shall be in accordance with IS-16444Part I (Latest version) or relevant IEC standards with dual mode (Credit/Prepay) support. Smart Prepaid Energy Meter shall be the followingfeatures:-(a) Capacitive touch/push button keypad in meter, Calibration LED and Load controlling feature and provision for TOD (Time of Day) tariffand R.T.C (Real Time Clock).(b) Additional Bluetooth features shall be enabled in meter for manually and remote vending token transfer and ABC (Authenticated Billing Code) reading collection through remotely (Mobile app suitable for Android/iOS/Windows phone).(c) Provided mobile app shall have a provision of offline and online vending token process.(d) SMS facility for providing the vending token to consumer mobile number provision shall be there.(e) All prepaid meters shall be provided with integrated cloud system for Smart prepaid energy meter. |
| 68 | Supply and installation of 3.5 KW Solar Off Grid System consisting of Solar Photo-Voltaic modules, Power Conditioning Unit, 1 x 5 KVA Off Grid Inverter, 4 Nos of solar Battery, Solar Module Mounting Structures,Electrical Accessories such as Cable Tie, Nut and Bolts, Interconnections, arrays to junction boxes, Junction boxes to DCDB to Inverter etc shall be selected to keep voltage drop and losses to the minimum, AC Combiner Box Enclosure With IP 65 Protection, Fuse Protection, Earthing Kit and Lightening Arrestors enclosure with IP65 Protection in order to protect in hazardous conditions from high voltage and current leakage etc complete all as specified and as directed. |
| 69 | M & Lfor Extension ofEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required, 4mm dia galvanised iron or steel wire complete all as specified and as specified. |
| 70 | M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plateNo-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (medium grade), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. [Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately.(b)PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c)Excavation/earthwork is deemed to be included in the quoted rate.] |
| 71 | Design, Manufacture, Supply and Installationat site in positioning, connecting, testing and commissioning of the following cubical type, dead front, 2mm thick sheet steel enclosed, free standing indoor type extendible Sub Distribution Panel with vermin proof hinged lockable doors for each compartment provide bus bar interconnections for incoming and outgoing including feeders earthing and paintingcomplete all as specified and directed.(Main Lighting & Power Distribution Panel for Offrs Mess)INCOMER(a)01 No 250 Amp FP MCCBBUS BARS(a)01 No 300 Amp FP busbar of aluminium alloy as per SLDOUTGOING(a)02 Nos 160 Amp FP MCCB(b)02 Nos 63 Amp FP MCCB(c)01 No 40 Amp FP MCCBINSTRUMENTS(a) 01 No 0 to 500 Volt digital voltmeter with Voltmeter Selector Switch and Protective SP MCB (96mmSquare)(b) 01 No 0 to 400 Amp digital Ammeter(c) 01 Set of Phase indicating Lamp (RYB) with protection fuses(d) 01 Set of breaker ON and OFF indicating Lamp(e) 01 Set auto trip indicating Lamp |
| 72 | Design, Manufacture, Supply and Installationat site in positioning, connecting, testing and commissioning of the following cubical type, dead front, 2mm thick sheet steel enclosed, free standing indoor type extendible Sub Distribution Panel with vermin proof hinged lockable doors for each compartment provide bus bar interconnections for incoming and outgoing including feeders earthing and paintingcomplete all as specified and directed.(Main Lighting & Power Distribution Panel for HQ Building)INCOMER(a)01 No 200 Amp FP MCCB(b)01 No 40 Amp FP MCCBBUS BARS(a)01 No 250 Amp FP busbar of aluminium alloy as per SLDOUTGOING(a)04 Nos 63 Amp FP MCCB(b)04 Nos 40 Amp FP MCCB(c)03 No 32 Amp FP MCCBINSTRUMENTS(a) 02 Nos 0 to 500 Volt digital voltmeter with Voltmeter Selector Switch and Protective SP MCB (96mmSquare)(b) 02 Nos 0 to 400 Amp digital Ammeter(c) 02 Sets of Phase indicating Lamp (RYB) with protection fuses(d) 02 Sets of breaker ON and OFF indicating Lamp(e) 02 Sets auto trip indicating Lamp |
| 73 | ROAD/FOOTPATH/SLAB CULVERT.Material & Labourfor 300 mm thick(compacted thickness) GSB (Granular sub base)grade V as per table 400-1 of MORTH, IRC specification, spreading in layers n.exc. 75 mm thick in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 8 to 15 tonne static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and as directed.directed |
| 74 | Material & Labour for 100mm thick(compacted thickness) Wet Mix Macadam (WMM)in a single layer 100mm thick compacted with crushed stone aggregate of specified grading ,spread using mechanical paver as specified, rolled and consolidated using 8 to 10 tonne capacity tandem vibratory power roller as specified to required gradient and camber to achieve minimum 98% density of MDD determined using modified procter density determination method as per IS 2720(Part-8) and as per MORTH clause 406 for NEW RIGID PAVEMENTcomplete all as specified and as directed. |
| 75 | M&L forpreparing bituminous surfaces of road and marking 2.5 mm thickcentre lines, stop lines, dashes, arrows etc and the like n exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS-3262-1989 with special applicator machine all as per manufactures instruction complete all as specified and directed. |
| 76 | SEWAGE DISPOSALConstruction Septic Tank for 25 users all as specified and as shown on drawings. |
| 77 | Construction Septic Tank for 50 users all as specified and as shown on drawings. |
| 78 | Construction Septic Tank for 100 users all as specified and as shown on drawings. |
| 79 | M & LSoakage wells for 25 Users,excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick batscomplete all as specified and as directed. |
| 80 | M & LSoakage wells for 50 Users,excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and as directed. |
| 81 | M & L Soakage wells for 100 users,excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and as directed. |
| 82 | EXTERNAL WATER SUPPLY. Construction of brick masonry valve pit with sub class ‘B’ brick in CM (1:4) of internal dimension 60cm x 60cm x 60cm depth with one brick wall thick over 15cm thick PCC in foundation with PCC (1:3:6) type C2 using 40mm graded aggregate, PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bedding and coping including 10mm thick rendering with CM (1:4) complete, 3.15 mm thick MS sheet cover with angle iron framing of size 50mm x 50mm x 6 mm with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on external and internal steel surfaces and two coats of black bituminous paint on hidden steel surfaces including necessary excavation and earth work in any type of soil complete all as specified and as directed. |
| 83 | Construction of brick masonry valve pit with sub class ‘B’ brick in CM (1:4) of internal dimension 90cm x 90cm x 90cm depth with one brick wall thick over 15cm thick PCC in foundation with PCC (1:3:6) type C2 using 40mm graded aggregate, PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bedding and coping including 10mm thick rendering with CM (1:4) complete, 3.15 mm thick MS sheet cover with angle iron framing of size 50mm x 50mm x 6 mm with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on external and internal steel surfaces and two coats of black bituminous paint on hidden steel surfaces including necessary excavation and earth work in any type of soil complete all as specified and as directed. |
| 84 | Construction of brick masonry valve pit with sub class ‘B’ brick in CM (1:4) of internal dimension 120cm x120cm x 120cm depth with one brick wall thick over 15cm thick PCC in foundation with PCC (1:3:6) type C2 using 40mm graded aggregate, PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bedding and coping including 10mm thick rendering with CM (1:4) complete, 3.15 mm thick MS sheet cover with angle iron framing of size 50mm x 50mm x 6 mm with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on external and internal steel surfaces and two coats of black bituminous paint on hidden steel surfaces including necessary excavation and earth work in any type of soil complete all as specified and as directed. |
| 85 | M&L for drilling of Trial bore of 200 mm dia upto 200 mtrs depth below ground level by any suitable method as per soil condition and CG WB report, through any kind of soil, boulders, rocks etc. for a bore size 250 x 150 mm dia as required at site including disposal of spoil from the site of work complete all as specified and as directed.NOTE :(i) After complete drilling of the bore hole electric logging to be carried out for exact selection of strata & the same will be measured & paid separately under relevant items of schedule.(ii) In case the results of the borehole/strata are found un-satisfactory & the tubewell is not likely to yield the specified quantity of water, the site shall be abandoned & the contr shall be paid for the boring part only. |
| 86 | M&L for development of trial bore by reaming upto 525 mm for 200 mtrs depth from ground level using any suitable method as per soil condition and CG WB report including disposal of spoil from the site of work complete all as specified and as directed. |
| 87 | Carrying out Electric logging Test of bore for precise delineation of granular zones & also the quality of ground water including report interpretation complete all as specified and as directed.NOTE:- Electric logging shall be carried out by any approved Govt Agency. |
| 88 | Supplying and assembling including jointing, lowering & fixing in position threaded uPVC casing pipe of 250 mm dia nominal size (internal), 12.5 mm wall thickness (Min), Class CM, as per IS 12818 : 2010(ISI marked) of suitable length including socket and jointing materials and jointing complete all as specified and as directed. |
| 89 | Supplying and assembling including jointing, lowering & fixing in position threaded uPVC casing pipe of 150 mm dia nominal size (internal), 7.5 mm wall thickness (Min), Class CM,as per IS 12818 : 2010(ISI marked) of suitable length including socket and jointing materials and jointingcomplete all as specified and as directed. |
| 90 | M & Lfor packing pea gravel 3 to 5 mm of size as per IS of natural shapebrought directly from river bed and packing around the casing pipe of MS to entire depth upto ground level complete all as specified and as directed |
| 91 | S&F MS centralising guide made out of MS flat iron 40x6 mm and 30 cm length all as specified in IS : 2800 (Part – 1) : 1991 complete all as specified and as directed. |
| 92 | Supplying and assembling including jointing, lowering & fixing in position threaded uPVC Screen slotted casing pipe of 150 mm dia nominal size (internal), 7.5 mm wall thickness (Min), Class CM, with slot 0.5 mmas per IS 12818 : 2010(ISI marked) of suitable length including socket and jointing materials and jointing complete all as specified and as directed. |
| 93 | Supply and fixing well cap suitable for 250 mm bore housing pipe made out of 6 mm thick steel plate complete all as specified and directed. NOTE : After completion of the work well cap will be used to keep the bore well closed until the submersible pumping set is installed. |
| 94 | Development of tube well with air compressor of suitable capacity till sand/mud free water of potable quality is obtained & to achieve minimum discharge capacity of 48000 LPH/max yeild(Compressor with accessories & tube etc. shall be arranged by the contractor) complete all as specified and as directed. |
| 95 | Development of tube well by over pumping 25% using suitable size/type of pump after completion of item above, including yield testing for tube wellas per IS requirements complete all as specified and as directed. NOTE :-Yield test of bore well shall be carried outin the presence of rep of Accepting Officer. |
| 96 | Supplyonly strata sample box with glass cover 3mm thick having internaldimension 1000x600x100mm made out of 20mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various depthevenly 2 mtr interval met in boring including strata chart in duplicate complete all as specified and as directed. |
| 97 | Testing of water (Raw Water & Treated Water) from approved Govt lab for potability by doing chemical and bacteriological analysis as per norms of WHO and submission of test reports to the to the Dept for entire satisfaction of the Dept. |
| 98 | Supply, lowering, jointing & testing MS Black column pipe3.0 mtr long, heavy duty, 80 mm bore, wall thickness 4.85 mm, both ends flanged, ISI Marked with heavy duty MS flanges not less than 20 mm screwed & welded inside & outside with pre-drilled holes including jointing with rubber gasket, nuts, bolts, washers & necessary grooves for facilitating submersible cables, steel ropes etc. The pipe shall be duly painted with anti-corrosive paint suitable for drinking water purpose complete all as specified and as directed. |
| 99 | S&F flat submersible cable 3 core 1100 volt grade multi stranded copper conductor PVC insulated, water proof, ISI marked of size 6 sqmm for connecting from starter to bore well submersible pump sets complete all as specified and as directed. |
| 100 | Supply and fixing bail plug of 150 mm internal dia threadedof minimum thickness 6 mm and 3 mtr long made up of mild steel and continuous welded by electric arc welding at both ends complete all as specified and directed. |
| 101 | Supply and fixing chain pully block, triple spur gear, 2 ton capacity with 3 mtr lift, manually operated complete with hooks high tensile forged steel confirming to IS : 3815 and load confirming to IS: 6216 and hand chain to IS: 2429 (Part-I) complete all as specified & as directed |
| 102 | Supply and fixing steel rope flexible 8 mm dia with GI clamps, nuts, bolts, washer etc for fixing of submersible pump set complete all as specified & as directed. |
| 103 | M&L for MS Taper reducer of 250 x 150 mm with and including socket threaded and by electric arc welding both sides complete all as specified and as directed. |
| 104 | S&F mild steel clamp of required length bend to shape suitable for 80 mm dia MS column pipe made out of 12 mm thick MS plate fabricated to shape, including drilling holes, nuts, bolts, washers etc complete all as specified & as directed. |
| 105 | M&L for fabricating of MS nipple 0.6 Mtr long 80 mm dia threaded both side externally. Flanged one end with heavy duty flange drilled four holes and provision of groove for cable entrance system complete all as specified and as directed. |
| 106 | M&L Water Meter Cast Iron body both end flange ISI marked suitable for fixing on 150mm diapipe line including nut, bolt, washer and rubber gasket required for joint all as specified and as directed. |
| 107 | M&L for Water Pressure Gauge dial Type with central knob 4\" dia having pressure range 0 to 10 Kg/Sq cm |
| 108 | M&L for rubber or fibre board gasket joints suitable for 80 mm dia flanged pipes including fixing of bolts, nuts, washers complete all as specified and as directed. |
| 109 | Supply only CHLORINE TEST KIT with coloured sample & test-tubes complete with all testing fitments and OT solution in Rexene finish box complete all as specified & as directed |
| 110 | Supply only PH test kit with coloured sample covered under BTB (range 6.0 to 7.0) or phenol red (range 6.8 to 8.4) & test-tubes with necessary fitments and 100 ml testing solution in rexene finish wooden box complete all as specified & as directed |
| 111 | Supply only IRON Test Kit & test-tubes with necessary fitments and testing solution in rexene finish box complete all as specified & as directed |
| 112 | Supply andinstall testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. Note :-(i)The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. |
| 113 | Supply andinstall testing and commissioning of horizontal monoblock pumping Setwith suitable capacity motor,voltage range 350 to 440 volts, AC 3 Phase, IP 55 Protection, Insulation class \"F\", Mechanical sealing, CI motor and Pump body, SS Pump Shaft, Bronze Impellar alongwith suitable star delta starter and electric connection with 3 Core stranded copper conductor of required size as per OEMsuitable for operation with operating minimum head 40 mtr and having capacity to discharge water 25 Ltrs per Sec with suction and discharge duly mounted on MS frame on foundation / platform grouted with MS bolts, nuts of required sizeproperly connected with suction and delivery water line, complete all as specified and as directed. |
| 114 | Supply, fixingand testing CI Reflux/ Non Return valve single door pattern with flanged ends PN-1.0 confirming to IS: 5312, ISI marked of size 100 mm dia bore with bypass arrangement including all fixing accessoriestype Cast iron flanged end with nuts, rubber gasket, bolts (full threaded), nuts & washers complete all as directed. |
| 115 | Design, supply, install, testing and commissioning Iron Removal/water treatment Plant of capacity 45 Cum/Hr (10000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :-(a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set |
| 116 | Item No 14.01 Contd (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set(c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set |
| 117 | Item No 14.01 & 14.02 Contd (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(ii) Contractor has to carry out necessary water testing and design the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (iii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. |
| 118 | Supply, install testing and commissioning of Altoch (Chlorine) Dosing Systemconsisting of :- (a) Receptacle for power-free automatic water sanitizer / conditioning treatment station with proportional dosing arrangement with following attachments: (i)Water Inlet Regulator (ii) Overflow Vent (iii) Water Outlet Regulator (for standalone gravity flow) (iv) Water Outlet Regulator (for offline automated gravity flow) (v)Drain valve (vi) Fluid Level controller (vii) Sludge Level Guage (viii) Station Base Assembly with Station Base Buffer (ix)Station Hood Assembly with multi-cavity arrangement (13) (x)Station Holding AssemblyMaterial of construction: Non-metallic thermoplastic, Maximum Temperature: 45°C, Capacity: 100 litres,Shape: Cylindrical(b) Custom cover for power-free automatic water sanitiser / conditioning treatment station with proportional dosing arrangement with following attachments:- (i)Refill Cavity Lids (13) (ii) In-built Level Switch & Processor (iii) ½ inch Processor Outlet & Processor Inlet connections (iv)Flexible Connecting Duct.Material of construction: Non-metallic, Maximum Temperature: 45°C,Shape: Circular(c) Additional Fittings:- (i)6 Mtr Suction Tubing (ii)PVC Ball Valve(iii) Plastic check valve (iv) Hose nipple Note :- Necessary connections with pump distribution line shalldeemed to be included in the quoted rate. |
| 119 | Supply and dozing Chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation through recommended dosing system complete all as specified and as directed. Replacement indication: visual & weight variationWater contact orifice design: Sealed when dry, exposed upon immersion.Operation type: Non contact, non inhalatory.Cylinder dia: 2.5 inches ± 0.5 inchesCylinder height: Minimum 10.0 inches ± 0.5 inches |
| 120 | Supply,Laying, Jointing & Testing 250mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laidin trenches/floor/wall etcin standard lengths,, ISI marked includingpush on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted. |
| 121 | Supply,Laying, Jointing & Testing 200mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laidin trenches/floor/wall etcin standard lengths,, ISI marked includingpush on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted. |
| 122 | Supply,Laying, Jointing & Testing 150mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laidin trenches/floor/wall etcin standard lengths,, ISI marked includingpush on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted. |
| 123 | Supply,Laying, Jointing & Testing 100mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laidin trenches/floor/wall etcin standard lengths,, ISI marked includingpush on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted. |
| 124 | Supply,Laying, Jointing & Testing 80mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laidin trenches/floor/wall etcin standard lengths,, ISI marked includingpush on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted. |
| 125 | M&L for fittings ISI marked of size 80 - 200 mm bore suitable forDI pipes class K-12, PN 10, as per IS: 9523 / 2000 with inside cement mortar lining andoutside Zinc coating with finishing layer of Black Bitumen, such as bends (any type radius & angle) tapers, tee pieces, single branches, Y junctions, double junctions, connecting pieces, Nuts & bolts, gaskets, flanges, including push on rubber joints etc. complete all as specified andas directed. |
| 126 | M&L for fittings ISI marked of size 250 -300 mm bore suitable forDI pipes class K-12, PN 10, as per IS: 9523 / 2000 with inside cement mortar lining andoutside Zinc coating with finishing layer of Black Bitumen, such as bends (any type radius & angle) tapers, tee pieces, single branches, Y junctions, double junctions, connecting pieces, Nuts & bolts, gaskets, flanges, including push on rubber joints etc. complete all as specified and directed. |
| 127 | Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 250 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed. |
| 128 | Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 200 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed. |
| 129 | Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 150 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed. |
| 130 | Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 100 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed. |
| 131 | Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 80 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed. |
| 132 | Supply, Installation, Testing & Commissioning ofFoot Valve conforming to IS 4038, 100 mm (4”) dia complete all as specified and as directed. |
| 133 | S & F Strainer Y type conforming to IS, size 100 mm (4”) diacomplete all as specified and as directed. |
| 134 | Supply, Assembling, Jointing & Fixing in position MS ERW pipe fine cut of internal dia 200 mm bore 2.0 Mtr long of thickness 5.4 mm confirming to IS 4270-2001 (ISI marked) both side flanged and covered with suitable dummy cover includingelectric arc welding both sides all as specified for header to make branch connections including painting, the pipes with single coat of epoxy primer and two coats of red enamelled paintcomplete all as specified andas directed. |
| 135 | Supply, Installation, Testing & Commissioning ofAir release valve, Cast iron, double air outlet, flanged ends,conforming to IS- 14845, 100 mm bore connected to the main line including all jointing materials as required complete all as specified and as directed. |
| 136 | Supply, Installation, Testing & Commissioning ofAir release valve, Cast iron, double air outlet, flanged ends,conforming to IS- 14845, 80 mm bore connected to the main line including all jointing materials as required complete all as specified and as directed. |
| 137 | Supply, Installation, Testing & Commissioningof indoor cubical typeLT Control Board, factory fabricated CPRI type tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 2.0 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50 x 50 x 6 mm angle iron suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl PCC platform/plinth of suitable size complete all as specified & as directed with & incl the following accessories :- (LT Panel, Pocket -2, Booster Pump House -3) complete all as specified and as directed:-BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos tinned copper 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \"F\" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables.INCOMING (a) MCCB 4P (Ics = 100% Icu) with adjustable thermal magnetic release, having breaking capaity 16 KA of rating 32 A - 01 No. |
| 138 | Item No 14.23 Contd......OUTGOING/INSTRUMENTATION SYSTEM :(a)MCCB, 3 Pole, 32 Amp rating, (Ics = 100% Icu) with adjustable thermal magnetic release, having breaking capaity 16 KA- 02 Nos.(b)MCB, SPN, 10 Amp rating,having breaking capaity 10 KA- 01 No.(c)Fully Automatic Panel mounted open execution star-delta starter suitable for 20 HP induction motor, 415 volts, including overload relay, auto timer & single phase preventer etc complete -02 Nos(d)Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 03 Nos.(e) Digital Ammeter with inbuilt selector switch and CT coil, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit,0-100 Amps - 3 Nos.(f) Indicator lamp with LED (red, yellow & blue), Set of Three - 02 Sets(g)APFC System with MD-XL Capacitors of 8 KVAR capacity to improve power factor to 0.99 . A set of Heavy duty capacitor, type MD-XL, 440 Volts with output capacity 8 KVAR, in suitable ste and configeration all possible set of automatic operation to maintain 0.99 Power Factor. Required MCB\"s, TP, \"C\" Series 415 Volts of required numbers and suitable ratings as per the capacity of the capacitors shall be provided with Microprocessor based control suitable for Power Factor Correction and indication of Lagging and Leading Power Factor. Suitable Power Contactor heavy duty shall be provided for Automatic operation of Each Capacitor. Digital Panel Meter for Current, Voltage,Frequency and Power Factor Having built in selector, Accuracy class-1.0 shall be provided. Detuning reactors of suitable size shall be provided to maintain THD less than 7 percent. The reactors shall be suitable to prevent amplification of 3rd and higher order harmonics |
| 139 | Item No 14.23 & 14.24 Contd......NOTE : (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be got approved from the Dept before placing final order to the manufacturer.(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 140 | Supply, Installation, Testing & Commissioning of indoor cubical typeLT Control Board, factory fabricated CPRI type tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 2.0 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50 x 50 x 6 mm angle iron suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl PCC platform/plinth of suitable size complete all as specified & as directed with & incl the following accessories :- (LT Panel for Bore Well)BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos tinned copper 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \"F\" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables.INCOMING (a) MCCB 4P (Ics = 100% Icu) with adjustable thermal magnetic release, having breaking capaity 16 KA of rating 32 A - 01 No. |
| 141 | Item No 14.26 Contd......OUTGOING/INSTRUMENTATION SYSTEM :(a)MCB, TP, 32 Amp rating, having breaking capaity 10 KA- 02 Nos.(01 x Spare) (b)MCB, SPN, 10 Amp rating,having breaking capaity 10 KA- 01 No.(c)Fully Automatic Panel mounted open execution star-delta starter suitable for 10 HP induction motor, 415 volts, including overload relay, auto timer & single phase preventer etc complete -02 Nos(One Spare)(d)Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 02 Nos.(e) Digital Ammeter with inbuilt selector switch and CT coil, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit,0-100 Amps - 2 Nos.(f) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set(g)APFC System with MD-XL Capacitors of 4 KVAR capacity to improve power factor to 0.99 . A set of Heavy duty capacitor, type MD-XL, 440 Volts with output capacity 4 KVAR, in suitable ste and configeration all possible set of automatic operation to maintain 0.99 Power Factor. Required MCB\"s, TP, \"C\" Series 415 Volts of required numbers and suitable ratings as per the capacity of the capacitors shall be provided with Microprocessor based control suitable for Power Factor Correction and indication of Lagging and Leading Power Factor. Suitable Power Contactor heavy duty shall be provided for Automatic operation of Each Capacitor. Digital Panel Meter for Current, Voltage,Frequency and Power Factor Having built in selector, Accuracy class-1.0 shall be provided. Detuning reactors of suitable size shall be provided to maintain THD less than 7 percent. The reactors shall be suitable to prevent amplification of 3rd and higher order harmonics. |
| 142 | Item No 14.26 & 14.27 Contd......NOTE : (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be got approved from the Dept before placing final order to the manufacturer.(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 143 | EXTERNAL ELECTRIFICATIONSupply, installation, testing and commissioningVacum Circuit Breaker, Indoor11 KV ofcapacity630 Amps, 3 Phase, 3 wire, 50 Hz, AC supply system, having rupturing capacity 350 MVA at 11 KV, 20 KA breaking capacity, totally enclosed metal clad switch gear as per IEC 62958-1 with overload and earth fault protection, digital ammeter, digital voltmeter, single bus bar for each phase, floor mounting, metal clad, indoor horizontal draw out type, horizontal/vertical isolation type with electrical and mechanical interlock and automatic safety shutter gear including pad locking arrangement, isolation plugs, assembly of 3 vaccum interrupters, with epoxy support insulations and self aligning finger type isolation contacts, truck having integral racking with necessary interlocks (for insertion and withdrawal of VCB),cubical should have not less than IP-43 Class degree of protection, copper bus bar, pre-wired for controller and accessories using copper conductor, suitable for side extension in both directions and provision for cable entry / outgoing system complete,manual and automatic motor charged independent closing/tripping spring,trip free operating mechanism with closing and tripping push bottons and mechanical breakers, including in built battery back up system and all standard fittings for incoming,outgoing including PCC foundation completeand comprising of the following :-(A) HT Vacuum Circuit Breaker Switchgear, Indoor type, dust and vermin proof, motorized as well as manually charged fully interlocked, horizontal draw out type, floor mounted, normal / highest working voltage – 11/12 KV, normal current – 630 A, 3-Phase, 50 HZ AC supply, Breaking capacity - 18.4 KA, Making capacity - 52.5 KA (p), insulation level KV(rms) / KV(p) -28/75, closing voltage – 110 V DC complete as per IS : 3427 & IS : 118 with all standards accessories and metering equipment and comprising the following :- |
| 144 | Item No 14.29 Contd......(i) HT CT 100/50/5-5 (Dual Core), Cast resin, Class 5 P 10 for protection and Class 1.0 for metering, 15 VA burden, short time rating – 18.4 KA for 1 sec, having IS : 2705 marking, suitable for 12 KV – 03 Nos.(ii) HT PT (1x3 Phase), draw out type, resin cast, dry type, having rating 11 KV / 110 V Class-1, with VA burden 15 having IS : 3156 marking – 01 No. (iii) Microprocessor based combined Over Current and Earth fault relays.(iv) Over and under voltage relays.(v) Tripping relays(vi) Digital power factor meter.(vii) Digital Voltmeter with selector switch 0-15 V.(viii) Digital Ammeter with selector switch.(ix)Digital frequency meter.(x) LED indicator lamps for RYB, phase healthy, Breaker ON / OFF, trip circuit healthy, spring charged.(xi) Breaker Control switch.(xii) Push buttons for check Trip Circuit healthy and Emergency trip.(xiii) Switch for closing / tripping of VCB.(xiv) Alarm annunciator for DC supply fail / trip.(xv) Power pack of suitable capacity with I/P voltage 220 V AC & O/P voltage 110 V DC.(xvi) Other standard accessories as specified by OEM. |
| 145 | Item No 14.29 & 14.30 Contd......NOTE :-(i)Design / Drawingof the HT VCB Panel Board showing the dimensions is to be obtained from the OEM / Auth supplier and is to be got approved from the dept placing final orderto the manufacturer.(ii)Necessary PCC foundation, cable ducts etc. shall be as per the recommendations of OEM and cost of the same is deemed to be included in the quoted rates.(iii)The cost of Primary / Secondary Injection Tests, Calibration etc. during the complete defect liability period as and when required is deemed to be included in the quoted rates.(iv)Anything missed out in the technical specifications but technically required for efficient working of the system is deemed to be included in the quoted rates.(v)The quoted rate shall be deemed to be inclusive of the factory inspection to be carried out by auth rep of Accepting Officer before dispatch and Pre-commissioning Inspection by SEI on ground. |
| 146 | Supply, installation, testing and commissioning Compact Sub Station (CSS-6) complete all as specified comprising of the following equipments :-(A) OUTDOOR ENCLOSUREOutdoor type enclosure having construction of galvanized steel sheet of thickness 2mm. The enclosure shall have IP 54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure shall be powder coated as per approved colour. Each compartment will be provided with door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided in each compartment.(B) HT SWITCHGEAR(i) HT 11 kV, 630 Amps, 350 MVA, 21 kA for 3 secs, SF6 insulated Non-extensible Compact Switchgear consisting of 01 No. fixed manual Vacuum Circuit breaker as Incomer and 01 No. manual load break switch as Outgoing and 01 No. fixed manual Vacuum Circuit Breaker as Outgoing with microprocessor based self powered relay in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMT + Inst) protection along with Class 1.0 Metering with interconnection between HT switchgear and transformer with Cable240 sqmm 3 Core aluminium unarmoured XLPE cable - 01 Set(ii) 11 kV single phase indoor resin cast PT of ratio 11 kV/rt 3/110 V/rt3, lass 0.5-3, Burden 5VA - 50VA, insulation level 28/75 kV, voltage factor 1.2 const and 1.9 for 30 sec, conforming to IS-3156 - 01 Set. (iii)11 kV single phase indoor resin cast CT of appropriate ratio as per manufactrurer\"s design, based on load, class 0.5, 5P10, Burden as per manufacturer\"s design, insulation level 28/75 KV, as per IS-2705- 01 Set. |
| 147 | Item No 14.32 Contd......(C) TRANSFORMER(i) 630 KVA, 11 kV/433 V, Dyn11, 3 phase, copper wound insulation class \"F\", Natural Air Cooling Cast Resin Dry Type Transformer with off circuit link +5% to -5% @ 2.5 % on HT side of transformer with WTI scanner with Alarm and trip contact and other standard accessories - 01 No.(D) LT PANEL1500 Amps rated aluminium bus bar for three phase and neutral with PVC sleeves supported on insulators - 04 NosINCOMING :-(i) ACB, 1000 Amps, 50 kA, 4 pole, rated operational voltage 415-690 V,Manual draw out (MDO) type microprocessor release with LSIG protection unit with over current, short circuit and earth fault protection with LCD display with the manual setting nobs & current measurement on screen and battery back up with over temperature protection and indication for protection unit shunt trip, under voltage release, Terminals, dedicated slots for releases,In Built Temperature Protection,Ics=Icu=Icw rated impulse withstand voltage 12 kV - 01 No.OUTGOING :- (i)MCCB FP, 400 Amps rating, Ics=100%Icu, 50 kA breaking capacity, adjustable thermal magnetic release - 04 Nos ( 01 No Spare) (ii)MCCB FP, 320 Amps rating, Ics=100%Icu, 35 kA breaking capacity, adjustable thermal magnetic release - 01 No. (iii)MCCB FP, 200 Amps rating, Ics=100%Icu, 35 kA breaking capacity, adjustable thermal magnetic release - 02 Nos.( 01 No Spare) (iv)MCCB FP, 160 Amps rating, Ics=100%Icu, 35 kA breaking capacity, adjustable thermal magnetic release - 01 No. (v) MCCB FP, 40 Amps rating, Ics=100%Icu, 25 kA breaking capacity, adjustable thermal magnetic release - 01 No. |
| 148 | Item No 14.32 & 14.33 Contd......(vi)Automatic Power Factor Correction (APFC) Systemwith capacitor heavy duty, type MD-XL , 440 V with output capacity 200 KVAR, capacitor bank shall be 12 Step in steps(2 x 50 + 2 x 25 + 1 x 15 + 2 x 10 + 2 x 5 + 2 x2 + 1 x 1 KVAR) ( each set coupled with each portion of LT panel ) and configuration to accommodate all possible set of automatic operation to maintain 0.99 power factor. Capacitor panelcontrolled by an intelligent microprocessor based PF correction relay with MCBs TP, “C” Series, 415 V of required sizes with required numbers and suitable ratings as per the capacity of the capacitors,Power Contactors heavy duty for suitable capacitors shall be provided for automatic operation of each capacitors with ON / OFF indications. Power Factor Capacitors shall confirm to IS 13340,13341,IEC 60831. The capacitors shall be suitable for 3 Phase 440 volts,50 Hz suitable for indoor use up to 55 deg C, fitted with discharge register with standard discharge timing 60 Sec as per IS. The Capacitor bank shall be provided with 7% detuned reactor filter to compensate third harmonics from being generated - 01 Set (vii)Digital Panel Meter for Amp, KWh, PF and other parameter flush mounting of size 96 x 96 mm - 01 No(viii) Digital Ammeter with inbuilt selector switch and CT coilwith suitable ratio, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit- 1 No.(ix) Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 01 No(x) LED indicating lamp (set of three) - 01 Set(xi) Internal control wiring with 1100 volts grade 1.5sqmm stranded copper cable as per colour coding with suitable size lugs as per requirement |
| 149 | Item No 14.32, 14.33 & 14.34 Contd......(E) INTERCONNECTION AND EARTHINGInterconnection between switchgear & transformer using 3 x 240 sqmm, 11 kV (E) XLPE cable with interconnection between transformer & LT switchgear using aluminium bus bars; Internal earthing connections by using 50 x 6 mm GI strips.(F) FOUNDATION : - PCC foundation (1:1.5:3 - M-20 grade) of approximate 300 mm depth above the ground the length & breadth of foundation should be at least 250mm more on all sides than the size of the enclosure. (CSS-6)NOTE :-1. Design, Drawingof the CSS showing the dimensions is to be obtained from the OEM / Auth supplier and shall be got approved from the Deptbefore placing final orderto the manufacturer.2. Anything missed out in the technical specifications but technically required for efficient working of the system is deemed to be included in the quoted rates. |
| 150 | Supply, installation, testing and commissioning Compact Sub Station (CSS-5) complete all as specified comprising of the following equipments :-(A) OUTDOOR ENCLOSUREOutdoor type enclosure having construction of galvanized steel sheet of thickness 2mm. The enclosure shall have IP 54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure shall be powder coated as per approved colour. Each compartment will be provided with door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided in each compartment.(B) HT SWITCHGEAR(i) HT 11 kV, 630 Amps, 350 MVA, 21 kA for 3 secs, SF6 insulated Non-extensible Compact Switchgear consisting of 01 No. fixed manual Vacuum Circuit breaker as Incomer and 01 No. manual load break switch as Outgoing and 01 No. fixed manual Vacuum Circuit Breaker as Outgoing with microprocessor based self powered relay in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMT + Inst) protection along with Class 1.0 Metering with interconnection between HT switchgear and transformer with Cable240 sqmm 3 Core aluminium unarmoured XLPE cable - 01 Set(ii) 11 kV single phase indoor resin cast PT of ratio 11 kV/rt 3/110 V/rt3, lass 0.5-3, Burden 5VA - 50VA, insulation level 28/75 kV, voltage factor 1.2 const and 1.9 for 30 sec, conforming to IS-3156 - 01 Set.(iii)11 kV single phase indoor resin cast CT of appropriate ratio as per manufactrurer\"s design, based on load, class 0.5, 5P10, Burden as per manufacturer\"s design, insulation level 28/75 KV, as per IS-2705- 01 Set. |
| 151 | Item No 14.36 Contd......(C) TRANSFORMER(i) 315 KVA, 11 kV/433 V, Dyn11, 3 phase, copper wound insulation class \"F\", Natural Air Cooling Cast Resin Dry Type Transformer with off circuit link +5% to -5% @ 2.5 % on HT side of transformer with WTI scanner with Alarm and trip contact and other standard accessories - 01 No.(D) LT PANEL600 Amps rated aluminium bus bar for three phase and neutral with PVC sleeves supported on insulators - 04 NosINCOMING :-(i)MCCB FP, 400 Amps rating, Ics=100%Icu, 35 kA breaking capacity, adjustable thermal magnetic release - 01 No OUTGOING :-(i)MCCB FP, 200 Amps rating, Ics=100%Icu, 25 kA breaking capacity, adjustable thermal magnetic release - 03 Nos ( 01 No Spare)(ii)MCCB FP, 160 Amps rating, Ics=100%Icu, 25 kA breaking capacity, adjustable thermal magnetic release - 01 No.(iii)MCCB FP, 100 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 02 Nos.( 01 No Spare)(iv)MCCB FP, 32 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 02 Nos. |
| 152 | Item No 14.36 & 14.37 Contd......(v)Automatic Power Factor Correction (APFC) Systemwith capacitor heavy duty, type MD-XL , 440 V with output capacity 60 KVAR, capacitor bank shall be 8 Step in steps(1 x 20 + 1 x 15 + 1 x 10 + 2 x 5 + 2 x 2 + 1 x 1KVAR) ( each set coupled with each portion of LT panel ) and configuration to accommodate all possible set of automatic operation to maintain 0.99 power factor. Capacitor panelcontrolled by an intelligent microprocessor based PF correction relay with MCBs TP, “C” Series, 415 V of required sizes with required numbers and suitable ratings as per the capacity of the capacitors,Power Contactors heavy duty for suitable capacitors shall be provided for automatic operation of each capacitors with ON / OFF indications. Power Factor Capacitors shall confirm to IS 13340,13341,IEC 60831. The capacitors shall be suitable for 3 Phase 440 volts,50 Hz suitable for indoor use up to 55 deg C, fitted with discharge register with standard discharge timing 60 Sec as per IS. The Capacitor bank shall be provided with 7% detuned reactor filter to compensate third harmonics from being generated - 01 Set (vi)Digital Panel Meter for Amp, KWh, PF and other parameter flush mounting of size 96 x 96 mm - 01 No(vii) Digital Ammeter with inbuilt selector switch and CT coilwith suitable ratio, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit- 1 No.(viii) Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 01 No(ix) LED indicating lamp (set of three) - 01 Set(x) Internal control wiring with 1100 volts grade 1.5sqmm stranded copper cable as per colour coding with suitable size lugs as per requirement |
| 153 | Item No 14.36, 14.37 & 14.38 Contd......(E) INTERCONNECTION AND EARTHINGInterconnection between switchgear & transformer using 3 x 240 sqmm, 11 kV (E) XLPE cable with interconnection between transformer & LT switchgear using aluminium bus bars; Internal earthing connections by using 50 x 6 mm GI strips.(F) FOUNDATION : - PCC foundation (1:1.5:3 - M-20 grade) of approximate 300 mm depth above the ground the length & breadth of foundation should be at least 250mm more on all sides than the size of the enclosure. (CSS-5)NOTE :-1. Design, Drawingof the CSS showing the dimensions is to be obtained from the OEM / Auth supplier and shall be got approved from the Deptbefore placing final orderto the manufacturer.2. Anything missed out in the technical specifications but technically required for efficient working of the system is deemed to be included in the quoted rates. |
| 154 | Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (LTP-17) |
| 155 | Item No 14.40 Contd......BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos tinned copper 250 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \"F\" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables.INCOMING (i)MCCB FP, 160 Amps rating, Ics=100%Icu, 25 kA breaking capacity, adjustable thermal magnetic release - 01 No OUTGOING/INSTRUMENTATION SYSTEM :(i)MCCB FP, 63 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 01 No.(ii) MCCB FP, 32 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 07 Nos ( 01 No Spare)(iii)Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 01 No.(iv) Digital Ammeter with inbuilt selector switch and CT coilwith suitable ratio, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digitfor0- 160 Amps - 1 No.(v) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set. |
| 156 | Item No 14.40 & 14.41 Contd......NOTE : (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be got approved from the Dept before placing final order to the manufacturer.(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 157 | M&L for cable route marker made up of PCC block (1:3:6) , Type C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with red colour paint( HT cable 11/33 KV orLT cable 1100 Volts) on route marker including necessary excavation and earthwork complete all as specified and as directed. NOTE : (i) The spacing between two consecutive cable route indicators shall not be more than 50meters & also shall be provided at each & every bend or corner.(ii)PCC will be measured and paid separately |
| 158 | Supply and Laying sub class \"B\" bricks laidin trenches for protection of UG cable with width equal to length of bricks, laid dry & flat complete all as specifiedandas directed. |
| 159 | Supply and Installation ofThree Way Ring Main Unit (RMU) (2 LBS + 01 VCB),One incoming, Two outgoing SF6 filled load break switch each of outdoor type of rating 630 Amp Aluminium bus bar with a faultclearing capacity of 21 KA for 3 sec, rated voltage 12 KV, operational voltage -11 KV, frequency -50Hz totally enclosed ring main unit with IP 67 protection for SF6 tank and IP 55 protection for outdoor enclosure with self powered microprocessor based numerical relay with over current and earth fault protection. Entire RMU should be tested for internal arc test of 21 KA for 1 Sec as per IEC-62271-200 standards including installation and testing, PCC foundation as per OEM complete all as specified and as directed. NOTE : (i) Design / drawing of the HT RMU showing the dimensions shall be obtained from the OEM/ AuthorisedSupplierandshall be got approved from the Dept before placing final order to the manufacturer.(ii) Necessary PCC foundation, cable ducts etc shall be as per the recommendations of OEM and cost of the same is deemedto be included in the quoted rates.(iii)The cost of Primary/Secondary Injection Tests, Caliberation etc during the complete defect liability period as and when required is deemed to be included in the quoted rates.(iv) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.(v) The quoted rate shall be deemed to be inclusive of the factory inspection which shall be carried out by Authorised Rep of Accepting Officer before despatch and Pre-commissioning inspection by SEI on ground. |
| 160 | STREET LIGHT/SECURITY LIGHTSupply and Fixing 9 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 155 mm, Section Length - 9000 mm, Thickness - 3 mm, Foundation type Base Plate (250 x 250 x 16 mm), Foundation Bolts - 4 Nos 24 mm dia, pitch circle dia 250 mm, bolt length 750 mm, projects bolt length 125 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal weldingcomplete all as specified and as directed. |
| 161 | Supply and Fixing 9 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 155 mm, Section Length - 9000 mm, Thickness - 3 mm, Foundation type Base Plate (250 x 250 x 16 mm), Foundation Bolts - 4 Nos 24 mm dia, pitch circle dia 250 mm, bolt length 750 mm, projects bolt length 125 mm , with Double type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding complete all as specified and as directed. |
| 162 | Supply and fixing LEDstreet light luminaire 35 Watt Energy saving and environmental friendly long lifemade up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP-65 protection and Impact resistance of IK07 with 10 KV Built-in Surge Protection device with high performance LEDs,System Lumen Efficacy- > 100 Lm/Watt,power factor >=0.90, polyester powder coated with high efficiency polycarbonate UV stabilised cover, tempered protective polycarbonate diffuser,integrated high efficiency electronic driver with lower THD ,Colour Temp (CCT)- 5700 K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete includingLEDs with certification LM 79 for luiminare, LM 80 for LED source including all necessary internally pre-wired and connecting up complete all as specified and as directed. |
| 163 | Supply and Fixing LEDstreet light luminaire 70 Watt Energy saving and environmental friendly long lifemade up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP-65 protection and Impact resistance of IK07 with 10 KV Built-in Surge Protection device with high performance LEDs,System Lumen Efficacy- > 115 Lm/Watt,power factor >=0.90, polyester powder coated with toughened glass having IP-66 protection, tempered protective polycarbonate diffuser,integrated high efficiency electronic driver with lower THD ,Colour Temp (CCT)- 6500 K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete includingLEDs with certification LM 79 for luiminare, LM 80 for LED source including all necessary internally pre-wired and connecting up complete all as specified and as directed. |
| 164 | Supply, Erection, Commissioning and Testing of High Galvanized Mast Light 16 Meter High suitable for 06 Nos. 1 x 200 W LED Flood light and having three point suspension system with steel wire rope of 6 mm did and double drum winch with luminaire mounting arm, 01 No. twin LED type aviation obstruction light including lamp, lightning arrestor spike, power tools including lamp, includingexcavation for RCC foundation complete with following and all as specified and as directed :-(a) High mast fabricated from steel plates conforming to BSEN-10025/IS:5986, cut and foldedto from a polygonal section. Mast shall be in two sections for 16 mtr heights having only longitudinal weld conforming to BS-5135/AWS. The mast is to be provided with a fully penetrated flange which shall be free from any laminations or incursions. The welded connection of the base flange shall be fully developed to the strength of the entire section. The base flange shall be provided with supplementary gussets between bolt holes to ensure elimination of helical stress concentration. For environmental protection of the mast, the entire fabricated mast shall be Hot Dip Galvanized (As per IS:2629) internally and externally having uniform thickness of average 86 microns for bottom / top sections respectively and certificate from the OEM regarding the same to be submitted alongwith the PV and test certificates. The minimum size 410 mm bottom, 150 mm top, 4 / 3 mm section thickness, PCD 490 mm with base plate of 570 X 25 mm with 2 wire rope system and accessories.include Head frame, Lantern ring with 6 nos. of lum arms (symmetrically arrangement), wire ropes, powertool, AOL bracket and 1 set of Foundation Accessories, each set consists of 8 nos.of M 30 x 850 mm bolts with Anchor plate and 10 % templates. |
| 165 | Item No 14.50 Contd......(b) An adequate door opening shall be provided at the base of the mast. The opening shall be such that it permits clear access to equipment’s lich winch, cable, wire rope, plug and socket etc. and also facilitates easy removal of the winch for servicing. The door opening shall be complete with a close fitting vandal resistant allen key locking with provision for external lock. The door opening shall be carefully designed and reinforced with adequate steel section so that the mast section at the base is unaffected, and undue buckling of the cut portion is prevented under heavy wind condition.(c) Mast structure shall sustain as assumed maximum reaction arising from wind speed as per IS-875 (Part-3) 1987 (three seconds) which is measured at a height of 10 mtrs above ground level.(d) The high mast shall be provided with accessories which include a raising and lowering system (R&L), trailing cable, power tool, lighting finial and aviation obstruction warning light.(e) The wire ropes shall be of stainless steel grade AISI 304 with minimum 6 mm diameter and 7/19 construction. Its central cores shall be also SS and have a minimum breaking strength of 2400 Kgs. The power tool shall be integral type suitable for handling the total head load. It shall have a mechanical torque limiter to ensure safety and also a manual handle shall be provided. |
| 166 | Item No 14.50 & 14.51 Contd......(f) Earthing 04 Nos. (02 for FP Box and 02 for High mast) complete with Galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below ground level with the top edge of the earth plate not less than 1.5 mtr below ground level and connected to galvanized iron earth lead strip 32 x 6 mm upto the required lengthby means of bolts, nuts, check nuts and washer of galvanized iron including PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) precast RCC cover slab including one handle made out of 8 mm dia round bar embedded in precast slab and 20 mm bore medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soilcomplete all as shown in EP No. 3 of SSR Part-I and testing on completion complete all as specified and as directed.(g)One number heavy duty hot dip galvanised finial shall be provided for the mast. The lightning finial shall be minimum 1.2 Mtr in length and shall be provided at the centre of the head frame. It shall be bolted solidly to the head frame to get a direct conducting path to the eath through the mast. The mast body acts as a conductor and earth Strip shall be connected to the mast door stiffener. |
| 167 | Item No 14.50 , 14.51 & 14.52 Contd......(h) Earthing 01 No. (for Surge protection device) complete with Galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below ground level with the top edge of the earth plate not less than 1.5 mtr below ground level and connected to galvanized iron wire 4 mmdia upto the required lengthby means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) precast RCC cover slab including one handle made out of 8 mm dia round bar embedded in precast slab and 20 mm bore medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soilcomplete all as shown in EP No. 3 of SSR Part-I and testing on completion complete all as specified and as directed.(j) The light luminaries shall be 200 W LED, CT>=5700 K made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor 5 KV or more and high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor >=0.90, operating range – 140 to 270 V, 50 Hz complete including suitable fixing arrangement , necessary MS angle/clamps, nuts, bolts etc. complete all as per OEM and as specified. (k) The aviation obstruction light shall be LED type with IP 65/66 protection and all as per the recommendations of the OEM complete. |
| 168 | Item No 14.50, 14.51, 14.52 & 14.53 Contd......(l) Supply and fixingcontrol panel as per OEM including Surge Protection Device, type-2, 40 KA, 3P+N, 2 module with 01 No. 32 Amps MCB TPN including internal connection done by using suitable size of copper wire complete all as specified and as directed.Note : 1. Design / Drawing of the High Mast Light showing the dimensions is to be obtained from the OEM / Auth supplier and is to be got approved from the departmentbefore placing final orderto the manufacturer.2. Anything missed out in the technical specifications but technically required for efficient working of the system is deemed to be included in the quoted rates. |
| 169 | Supply and LayingPVC Insulated PVC sheathed LT cableunarmoured with stranded copper conductor of size 2.5 Sqmm x3 core drawn into steel pole for connection or security/street light fitting from junction box complete all as directed and as specified |
| 170 | Supply,Installation, Testing and Commissioning of LED based Solar street light system stand alone type, onpole(MNRE specification) incl LED street light system of 1 x 36 watt/ nearest higher available rating, system lumen not less than 3150 lm, capable of working on DC 12 volts power from battery unit, being charged by the solar photovoltaic array panel through charge controller, luminaire fixing arm made out of ISI marked GI pipe medium grade of dia 50 mm of length not less than 0.5 mtr with suitable fixing arrangementsas per manufacturer etc. The details of different items are as under :-(a) Luminaire :- IP 65, full body, aluminium pressure die cast housing, LED type 1 x 30 W/ nearest higher available rating all as specified and directed suitable for battery system of 12 Volts DC.(b) Maintenance free Lithium Ion Battery 1 No of minimum 12V, 100 AH @ C10 rating (12 Volt system) all as specified and directed.(c) Poly crystalline solar photovoltaic array panel conforming to all relevant IEC/IS standards of best quality. Solar Panel shall bemin 125 Wp(12 Volt system). The panel shall be suitably connected to battery through charge controller for its charging all as specified and directed.(d) Solar Charge controller MPPT based conforming to relevant IEC/IS standards shall be provided to charge the battery from solar photo voltaic array panel all as specified and directed including suitable protection mechanism. |
| 171 | Item No 14.56Contd......(e) Battery box made out of 2 mm thick MS sheet powder coated with minimum 60 micron thickness, weather proof, including locking arrangement for housing batteries and necessary arrangement to fix on pole with suitable MS angle/ flat iron support duly painted with two coat of synthetic enamel paint over a coat of primer all as specified and as directed.(f) Steel tubular pole, hot dip galvanised, 80 mm dia, 3 metre height, conforming to relevant IS/IEC standards. The pipe shall conform to IS 1161. Thickness and other specification of pole shall be as per manufacturer and shall be capable of taking all types of load, wind load etc at Panagarh area. The earth work, foundation etc of pole shall be as per manufacturer guidelines and quoted rate is deemed to be included all as directed.(g) All the electrical fittings, batteries including box, solar photo voltaic array panel shall be fixed on apole of suitable height from ground level all as specified and directed.Note :- All the items like solar photo voltaic array panel, luminaire, solar charge controller, batteries etc shall confrom to relevant IEC/IS standards. |
| 172 | Supply,install, testingand commissioningout door type Street light LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB amps rated to MCCB input and MCCB/MCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mmduly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:-(SLP-3) |
| 173 | Item No 14.58 Contd......BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos tinned copper 50 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \"F\" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables.INCOMING (i)MCCB FP, 25 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 01 NoOUTGOING/INSTRUMENTATION SYSTEM :(i)MCB TPN 20 Amps rating, 10 kA breaking capacity,\"C\" curve, ISI marked - 02 Nos ( 01 No Spare)(ii) MCB SPN 6 Amps rating, 10 kA breaking capacity,\"C\" curve, ISI marked- 03 Nos( 01 No Spare) (iii)Analog time switch, Programmed via captive segment.Power supply: 230 V~ 50/60 Hz,3-Position override switch \"ON-AUTO-OFF\" on frontpanel. 16 Amp - 01 No(iv)ML-2 Power Contactor, 415 Volt, 3 Pole, Conforming to IS/IEC 60947-4-1 & IEC 60947-4-1, Standard Coil Voltage 240V, rating 40 Amps - 01 No(v)Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 01 No.(vi) Digital Ammeter with inbuilt selector switch and CT coilwith suitable ratio, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit ,for 0-25 Amps - 1 No.(vii) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set. |
| 174 | Item No 14.58& 14.59 Contd......NOTE : (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be got approved from the Dept before placing final order to the manufacturer.(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 175 | STANDBY POWER SUPPLY Supply, Installation, Testing and Commissioning ofSilent type built in within an acoustic enclosure Diesel Enginedriven Generating set water cooled including AMF panel for standby power supply 415 volts, 3 Phase, 4 wire, 50 cycles / sec,0.8 power factor,125 KVA (100 KW) or next higher standard size available KVA,1500 RPM. Self exicited self regulated brushless AC generator installed. The alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter 12 volt. Acoustic enclosure suitable for ambient condition at Panagarh and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000to meet exhaust emission test as per revised MoEF norms/as per CPCB. Fuel tank capacity not less than 08 hours fuel requirement & battery as reccommended by OEMbattery leads, sound proof canopy etc. with features for automatic shutdown in the event ofa circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based gen-set controller with the following under-mentioned features complete all as specifiedand as directed (DG-11):-Note :- The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS Standards design.(A)Alternator :-Standard design alternator rated at 125 KVA / nearest higher available capacityat 0.8 (lag) power factor AC,3 - phase 4 - wire, 415 volts, 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proofbrushless design with winding in pole faces, insulating class \"H\" and voltage regulation of+ 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequecy regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. |
| 176 | Item No 14.61Contd......(i) Insualation class - \"H\"(ii) Temparature rise Class - \"H\"(iii) Excitation : Self Excited(iv) Regulation performance: The voltage is kept constant with + 1%.(v) Frequency regulation + 1%(B) Diesel Engine: - Adequate capacity of Diesel enginewater cooled to drive independently above alternator and after considering de-rating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylindermulti stroke direct injection,cold starting 1500 RPM, as per relevant IS/BS complete, with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-(i) Fly wheel with housing(ii)Cooling system :- Moulded radiator with fan & belts.(iii) Cooling Water pump : - Centrifugal type belt driven.(iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade. MS Exhaust pipe with bends/flanges and all accessories to be supplied and erected as per OEM recommendation. The Exhaust Pipe shall be insulated with low resin bounded wool of min 75 mm thickness min 144 Kg/m density. The dia/thickness and Stack height of the Exhaust pipe shall be as per OEM recommendation and CPCB norms. The minimum height of Stack to be provided with each gererator set shall be worked outas per CPCB norms.Turbo charger typeExhaust manifoldSilencer : Residential type |
| 177 | Item No 14.61 & 14.62Contd......(v) Fuel System :- Diesel Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequency regulation. Comprising with Fuel Filters and Fuel Hoses.(vi) Lub oil System :-Comprising of Lubricating oil filter, Lubricating oil pump etc.(vii) Air Intake System :- Air intake Manifold, Air cleaner dry type etc(viii) Governer Electronic type(ix) Starting System :- Electric Self starter with and including battery charging alternator 24 Volts DC.(x) Batteries :- Batteries of maintenance free of capacity 12 V, 180 AH- 02 Nos complete with copper conductor multistranded leads of suitable length fromself starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified.(aa) Start and stop push button.(ab) Ignition key / Switch.(ac) Radiator with blower fan & first fill of coolant oil.(ad) Corrosion inhibitor coolant. |
| 178 | Item No 14.61,14.62& 14.63 Contd......(xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display.(xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine.(xiii) Coupling arrangement : - Flexible coupling.(xiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.(xv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes as per manufacturer. |
| 179 | Item No 14.61, 14.62 , 14.63 & 14.64 Contd......(xvi) Fuel Tank :- Daily service fuel tank made complete on a common base inside the acoustic enclosure as per manufacturer guidelines for min 8 hrs continuous operation.(xvii) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.(xviii) Battery Charger shall be provided as per manufacturer guidelines.(xix)The DG Set shall comply to the emission limits requirement as per Govt of India,The DG Set shall be complied with all test requirements as stipulated in the gazette notification. All relevant test results from NABL accredited lab shall be produced.(C) AMF Panel :- Factory madecontrol cubical made out of 2mm thick CRCA sheet dust and vermin proof totally encosed with front and rear opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated painted, copper bus bar of one and half times the rated load of 125 KVA alternator complete with internal wiring with PVC insulated single core copper condutor multistranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole ACB/MCCBs and Contactors. The size / rating of all the connected accessories viz. Contactors, relays, timers, bus-bars, connecting cables etc. of the AMF Panel shall be in conformity with the I/C and O/G ACBs/MCCBs and as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard fitting shall be as follows: |
| 180 | Item No 14.61, 14.62 , 14.63 ,14.64 & 14.65 Contd......(a) Digital Ammeter with selector switch of suitable capacity with CTs - 1 set.(b) Digital Volt meter with slector switch of 0 to 500 volts - 1 Set.(c) Digital Frequency meter - 1 No.(d) Digital KW meter - 1 No.(e) Digital KWH meter panel mounted type- 1 No.(f) Digital PF meter - 1 No.(g) Annuciation with indication lamps for :-(i) Low lub oil pressure.(ii) High Water Temparature.(iii) Engine over speed.(iv) Battery low voltage.(v)Over voltage, under voltage and over current. (vi) Display shall be alphanumeric LCD display with LED backlight.Controls and Records:-(a) Load on Indication (b) Load off indication (c) Engine start push button(d) Engine stop push button(e) Fault accept / reset push button (f) Battery Charger shall be provided as per manufacturer guidelines (g) Suitable to provide a record of most recent fault conditions & fault history.(h) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA , frequency etc.(j)Complete engine data viz, starting battery voltage, engine temp, engine runnning hours, engine oil pressure etc.(k)Control incl provn of service adjustment & calibration of DG control functions. |
| 181 | Item No 14.61 to 14.66 Contd......(D) Civil Works :- All civil works including PCC plat form and related foundations including for panel and equipments including making good of distrubed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer.Note:- The contractor shall arrange for artificial load for testing of DG Set at site and the cost is deemed to be included in the above offer.(E) Acoustic Enclosure:- Manufactured by OEM suitable for 125 KVA DG Set.(i) Tested by NABL approved lab as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating setbattery should be inside the enclosure. (iv) Fuel tank should be inside the enclosure, however, the fuel storage shall be enough for 8 hrs continuous operation. If required contractor may arrange outside fuel storage capacity to achieve this (v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick (c) Sound Insulation :- 100 mm thick rock wool (minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level.(vi) The acoustic should be composite in construction and fully assembled integral unit. (vii) The DG Set should be provided with external Emergency stop push button. (viii) The enclosure should be suitably internally illuminated by CFL/FTL Lamp fittings. (ix) The noise level should be 75 dB at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre treatment process.The base frame should be painted with epoxy based black shade. |
| 182 | Item No 14.61 to 14.67 Contd......Note :- (i) The complete DG Set shall be procured from authorised OEM. Design / Drawing of the AMF Panel and DG Set showing the dimensions is to be obtained from the OEM / Auth supplier and shallbe got approved from the Dept before placing final orderto the manufacturer. Desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation.(iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests.(iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test.(v)Necessary PCC foundation / plinthshall be as per the recommendations of OEM and cost of the same is deemed to be included in the quoted rates.(vi) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates.(vii) DG Set shall be supplied with one complete Set of double open end jaw spanner and one complete Set of Ring Spanner Set.(viii) Factory Test shall be carried out by Testing officer nominated by accepting officer. |
| 183 | Supply, installation, testing and commissioning of LT feeder pillar box suitable for 415 volts, 50Hz, 3 phase 4 wire, size 1.5m x 1.2m x 0.6m, outdoor type for accomodating the following accesories totally enclosed self supporing structure/cubicle, fully compartmentalised type, weather proof, protection IP 52, CPRI approved, suitable for outdoor use, with bottom cable entry with suitable cable gland, structure made out of 3.15mm thick CRCA sheet with angle iron frame work and legs of ISA 50 x 50 x 5mm, with four legs grouted with PCC 1:2:4 foundation block with suitable mounting arrangement for bus bars, volt meters, ammeter, changover switch and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking aarangement, provision of louvers at sides, structure treated under 7-tank metal treatment process and duly powder coated, completed all as specified and directed:-BUS BARS :-Electronic copper bus bar 320 Amps, supported on non hygroscopic fibres and brass screws for mounting - 04 Nos. INCOMMING :-MCCB 4 pole 415 volt, 160 Amp of breaking capacity 25 KA -01 No. INDICATING DEVICE(a) LED indicating lamps for main supply indicating R, Y, B- 01 Set (Set of 3). (b) Multifunctional meter for V, A, F, KW, KWh including CT\"s with suitable CT ratio - 01 No. (c) Timer switch 1P module, 24 hours programe, progamable every 15 mins backup of 100 hrs currentcapacity of 16A, with 01 change over (1CO) -01 No.OUTGOING(a) MCCB 4 pole 160 Amp 16 KA -02 Nos. (b)MCCB 2P, 0 to 32 Amps, 16 KA - 03 Nos. (c)Power contactor 3P, 32 Amps with AC coil - 01 No. |
| 184 | Supply,install, testingand commissioningout door type DG LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (DGP-6 for 125 KVA DG) |
| 185 | Item No 14.70 Contd...... BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos tinned copper 300 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \"F\" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables.INCOMING (i)MCCB FP, 200 Amps rating, Ics=100%Icu, 25 kA breaking capacity, adjustable thermal magnetic release - 01 NoOUTGOING/INSTRUMENTATION SYSTEM :(i)MCCB FP, 63 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 04 Nos ( 01 No Spare)(ii) MCCB FP, 40 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 01 No (iii) MCCB FP, 32 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 02 Nos( 01 No Spare)(iv) MCCB FP, 25 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 01 No (v)Digital voltmeter with inbuilt selector switch, 3 phase, Accuracy Class-1.0, Flush mounting 96 x 96 mm,Input Voltage measurement range 50 - 520 Volts AC (P-P) - 01 No.(vi) Digital Ammeter with inbuilt selector switch and CT coilwith suitable ratio, 3 phase, Accuracy Class-1.0 ,Flush mounting 96 x 96 mm, 4 digit ,for 0-200 Amps - 1 No.(vii) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set. |
| 186 | Item No 14.70 & 14.71 Contd......NOTE : (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be got approved from the Dept before placing final order to the manufacturer.(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 187 | FLAMEPROOF ELECTRICAL SERVICESM and L for Point wiring complete with 1.5 sqmm single core PVC insulatedunsheathed FRLS cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including stove enamelled steel conduit and conduit accessories ISI marked concealed in wall / ceiling/ fixed to roofetc and including provision of 1.5 sqmm PVC insulatedmultistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor connected with Flame proof switch (specified separetely )etc completeall as specified and as directed.Note :- (i) Wiring shall be carried out all as per IS /relevant standard.(ii) Switch board to be provided in the passage/ lobby i.e out side of the Store/Room (iii) Metal flush box and cover outer plate shall be included in the quoted rate. Cutting chases, making good disturbed surface shall be included in quoted lump sum of schedule \"A\" Part-I. |
| 188 | M & Lfor wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed as required. (2x2.5 sq. mm +1x2.5 sq. mm earth wire in steel Conduit) complete all as specified and as directed. |
| 189 | S&F forflameproof, Integral LED Flying Saucer LED lightfittings40W including integral reflector made of aluminium alloy LM 6, with electronic driver, connector block etc including LED and all accessories pre-wired with all accessories completeall as specified and as directed. |
| 190 | S& F forFlame Rotary Switch 6A SP with separate terminal junction box dual chamber completeall as specified and as directed. |
| 191 | S& F Flame proof Switch Socket 6A SP with 3-Pin Plug and separate terminal junction box dual chamber completeall as specified and as directed. |
| 192 | S & F heavy duty Flame Proof exhaust fan 450 mm sweep MS Body,3 wing 1400 rpm, single phase 230/240 volts copper wounds complete with all accessories as louvers shutters etcincluding making connection through 3 core PVC copper wire run through flexible pipe. Single phase type complete all as specified and as directed. |
| 193 | EARTHINGM&L for earthing complete with galvanized steel pipe electrode 40mm bore , medium grade, 2.5 mtr length buried directly and perferably vertical in ground with top edge not less than 1.25 meters below ground level connected withearthing lead of 4mm dia galvanisediron or steel wire bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plateNo-2 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (medium grade), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completioncomplete all as specified and directed. [Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately.(b)PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c)Excavation/earthwork is deemed to be included in the quoted rate.] |
| 194 | M & L Earthing complete with Galvanized steel earth plate electrode 600 mm x 600mm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32 x 6 mmby means of bolts, nuts,check nuts and washers protected by 40mm bore medium grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.[Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately.(b)Excavation/earthwork is deemed to be included in the quoted rate.] |
| 195 | M & L Earthing complete with copper earth plate electrode 600 mm x 600mm x 3.15mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with copper strip of size 32 x 6 mmby means of bolts, nuts,check nuts and washers protected by 40mm bore medium grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.[Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) excavation/earthwork is deemed to be included in the quoted rate.] |
| 196 | DEMOLITION/DISMANTLING.Dismantling old barbed wire fencing of any description from RCC/Steel fencing post complete all as directed. |
| 197 | SCHEDULE \"A\" PART-XIV (SCHEDULE OF CREDIT) Note :- Amount of Rs.6,63,500.00 shall be deducted from the total quoted amount of BOQ |