Tata Memorial Centre has published Tender For Estimated Labour Rate Contract For Installation Testing Commissioning Of Hvac And Fire Fighting Items And Sitc Of Required Items As Per Design And Site Condition At 4Th And 5Th Floor Wing C Hospital Building Hbchrc New Chandigarh Punjab 14. Submission Date for this Tender is 16-01-2024. Fire Fighting Consumable Tenders in S.A.S Nagar Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-Jan-2024 | Corrigendum | Date | 16-01-2024 |
Sl. No. | Item Description |
1 | Installation, Testing and commissioning of Horizontal floor mounted AHU, frame made up of Hollow extruded Aluminum profile, chilled water double skin type made of 25 mm thick PUF injected (40 kg/mm3 density) panels consisting of G.I. casing of thickness 0.6 mm outside (pre-coated) and 0.6mm inside layer, complete with blower section (DIDW Centrifugal backward curved fan) suitable for static pressure as detailed below, minimum 2 bend GSS/ PVC eliminators,cooling coil section with aluminum finned copper tubes (tube thickness not less than 0.8 mm and dia not less than 1/2”) suitable 6 row cooling coil and 2 row deep coil for heating coil with SS 304 casing, 12 FPI, filter sections with 50mm thick metal viscous/ washable synthetic type air pre-filters (90% down to 10 Micron), Electrical cable of suitable size as per AHUs from panel to AHU to make it run , TEFC belt driven motor suitable for 415 + 10% volts, 50Hz, 3 phase, A.C Installation, Testing and commissioning , SS 304 drain pan duly insulated, etc. Complete as per specifications and instructions of Engineer-in-charge, of following capacities. AHU should be supplied with Installation, Testing and commissioningVCD. AHU is having one working and one stand by motor. AHU is eurovent certified. |
2 | 12000 CFM/ 55 MM static pressure / 26 TR Cooling Coil ( 4th Floor ) |
3 | 12000 CFM/ 55 MM static pressure / 30 TR Cooling Coil ( 5Th floor ) |
4 | Supply, shifting and installationofVI pads and PCC blocks for installation of AHUs. |
5 | Shifting, Cutting,welding, Installation, Testing and commissioning ofthefollowingMSclass‘C’pipesoffollowingdiameterandof6mtr standard lengths for Chilled water lines including insulation. |
6 | 2.1/2" dia size ( 65 MM ) |
7 | 2" dia size ( 50 MM ) |
8 | Butterfly Valve Shifting, Installation, Testing and commissioningof Insulated ( 25 MM nitrile insulation ) BUTTERFLY VALVE (MANUAL)with CI body CI Disc. Nitrile RubberSeal & O-Ring PN16Pressure rating forchilledwater,complete with flanges, nut bolt etc. |
9 | 2.1/2" dia size ( 65 MM ) |
10 | 2" dia size ( 50 MM ) |
11 | PIBCV Valve Shifting, Installation, Testing and commissioningof Insulated ( 25 MM nitrile insulation with 26 G Al Cladding )PIBCV Valve with CI bodyCI disc. Valves should be installed with thermostat, actuators or any other accesories to run the AHUs in automatic mode without BMS system. Vendor should test and offer witness testing of all AHUs for control of Air condtioning parameters.. |
12 | 2.1/2" dia size ( 65 MM ) |
13 | 2" dia size ( 50 MM ) |
14 | Y Strainer Valve Shifting, Installation, Testing and commissioningof Insulated ( 25 MM nitrile insulation with 26 G Al Cladding ) Y strainer with CI body. Nitrile Rubber Seal & O-Ring PN 16 Pressure rating for chilled water. complete with flanges, nut bolt etc. |
15 | 2.1/2" dia size ( 65 MM ) |
16 | 2" dia size ( 50 MM ) |
17 | Temperature Guage Shifting, Installation, Testing and commissioningof temperature guage suitable for measuring chilled water and hot water inlet and outlet temperatures of AHU. |
18 | Pressure Guage Shifting, Installation, Testing and commissioning ofdialtypepressureguage(0-10Kg) formeasuringchilledwaterandhotwater temperature at AHU inlet and outlet. |
19 | Shifting, Installation, Testing and commissioningof auto air vents suitable for AHU mentioned at SL 1 for hot water and chilled water. |
20 | Installation, Testing and commissioningof Ball Valves ( SS in MOC type Only) 25 MM |
21 | 10/12 MMAir vent |
22 | AIR DISTRIBUTION GI Ducts Shifting, fabrication , InstallationofGI Duct for HVACducting work of following sizesfor Supplyair & return air system complete with site fabrication, installation including angle support and nitrile rubber gasket. Vendor should fabricate ducts at site from available GI sheets as per site conditions. |
23 | 22 Guage |
24 | 24 Guage |
25 | Thermal Insulation Shifting , cutting , Installation ofclosedcellnitrilerubberthermalinsulationClass"O"forductinsulationof standard dimention). Material should be supplied in rolls. |
26 | Accoustic Insulation Shifting , cutting , Installationof15mm aquasoundopencell nitrile rubberinsulation ofductwithstandard dimension. Make - APL/AFlex / Kflex /Armacell / Aerofoam |
27 | Accoustic Insulation(AHU Room) Shifting , cutting , Installation of 50 mm Resin bonded glass wool with 32 kg/cm3 density with 600x600 C channel of GI with aluminium perforated sheet 0.6 mm thick with tissue paper. |
28 | Fire Damper Shifting , Installation, Testing and commissioningof fire dampers for Supplyair duct/return air path i/c control wiring, the damper shall be motorized as required. Size : 1700x500 mm |
29 | Shifting , Installation, Testing and commissioningof Actuators |
30 | Shifting , Installation, Testing and commissioningofControllers |
31 | Shifting , cutting , Installation of canvas for connection of AHUs and ducts |
32 | Grills/ Diffusers Shifting, Installation of Supplyairdiffusersofpowdercoatedaluminiumwithaluminiumvolume control Dampers with anti smudge ring & removable core. Standard size 595x595 (375X375 neck size) |
33 | Shifting, Installation ofreturnairdiffusersofpowdercoatedaluminiumwithoutvolumecontrol Dampers anti smudge ring & removable core. Standard size 595x595 (375X375 neck size) |
34 | Shifting, Installation fixingofpowdercoatedextrudedaluminiumreturnAirgrillswithlouversbut without volume control Damper complete as required. Size |
35 | Shifting, Installation of freshExternalweatherlouversmanufacturedfrom18GGIframecompletewithVCD, blades, bird screen etc.( Size - 700x300 mm) |
36 | ELECTRICAL ACCESSORIES Shifting, Installation, Testing and commissioning of wallmounted type electricalpanelsincludingsystem control wiringwith incoming, outgoingfeeders as described below :- Installation, Testing and commissioning of wallmounted type electricalpanelsincludingsystem control wiringwith incoming, outgoingfeeders as described below :- a.40A TPN MCCB for 7.5 HP motor - 01 Set. b.RYB LED type indication lights --- 01 Set. c.VFD Installation, Testing and commissioningand simulation d. BypassFullyautomaticDOLstarterwithbuilt insingle phasingpreventer,contactor, overload relay suitable for 7.5 HP Fan Motor --- 01 Set. e. Auto-Manualtypeselectorswitchtofacilitate autostartoffansafterrestorationof power -- 01 Set. f.Control wiring and safety circuit as required with Start-Stop PBs and LED type "ON"/ "OFF" indication lights. g.Control wiring and safety circuit as required with Start-Stop PBs and LED type "ON"/ "OFF" indication lights. VFD MAKE- Danfoss/ABB/Fuji/Siemens Panel Accessories |
37 | Cables Shifting , Installation, Testing and commissioning of thefollowingsizesof1.1KVarmouredXLPEinsulatedaluminium/copper conductor cables. Cables shall be inclusive conductor cables. Cables shall be inclusive of all clamps,saddles,screws,cableidentificationtags,insulatingtapes,affecting terminal connections to the equipment as per the specifications and as required. |
38 | 3 C x 4 Sq.mm, Cu |
39 | 3 C x 2.5 Sq.mm, Cu |
40 | 3 C x 1.5 Sq.mm, flexible control cable copper |
41 | Cable Tray Shifting , Installationof following sizes of GI cable trays dulypainted, perforated type along with necessary elbows, bends, reducers etc. anchored along the wall/ suspended from the slab/ laid on terrace with necessary MS supports, anchor fasters, threaded rods etc. 150 x 50 x 1.6 MM |
42 | Shifting , Installation of the following bare GI tape/ GI wire including providing all fixing accessories & effecting proper connections. 25 x 3 GI Strip |
43 | Shifting , Installation, Testing and commissioning 2 - 2.5 TR Fix speed Splitair-conditioning equipment using CFC / HCFC - free refrigerant,having BEE rating of minimum 3-star with outdoor stand. Charges include scaffolding/ miscellaneous chargesfor installation of out door unit of these ACs on 4th and 5th floor level" |
44 | 4F- HUB ROOM(1W+1S) |
45 | 5F- HUB ROOM (1W+1S) |
46 | Shifting , Installation, Testing and commissioning of Refrigerant pipe with 19 mm thick Class-O closed cell elastometricnitrile rubber tubular sleeves sections should be supplied seperatlyRefrigerant pipe with 19 mm thick Class-O closed cell elastometricnitrile rubber tubular sleeves sections should be supplied seperatly. Cost of refrigerant, Copper fittings , vaccumiazationandNitrogentesting etc. will be included. |
47 | 9.5 mm |
48 | 15.88 mm |
49 | Shifting , Installation of PVC pipe dia 25 mm for Drain pipe |
50 | Shifting , Installation, Testing and commissioning Drain pump |
51 | Shifting , Installationof SS Flexible hose pipe for installing fire sprinklers |
52 | Shifting , Installationof upright fire sprinklers |
53 | Shifting, Cutting,welding, Installation, Testing and commissioningof MS C class pipe 25 mm Dia of standard length 6 m |
54 | Cable Providing and fixing ofof thefollowingsizesof1.1KVarmouredXLPEinsulatedaluminium/copper conductor cables. Cables shall be inclusive conductor cables. Cables shall be inclusive of all clamps,saddles,screws,cableidentificationtags,insulatingtapes,affecting terminal connections to the equipment as per the specifications and as required. |
55 | 3 C x 1.5 Sq.mm, Cu |
56 | 2 C x 1.5 Sq.mm Cu |
57 | Opening in brick wall for supply and return air duct |
58 | Flexible Duct Providing and fixing of fire rated as per BS 476 part 5 & 6 insulated flexible ductof thefollowingsizes: Make : Sphere / Caryaire |
59 | 300 mm dia |
60 | 250 mm dia |
61 | 200 mm dia |
62 | Spigot for flexible Duct Providing and fixing of Spigot for insulated flexible ductof thefollowingsizes |
63 | 300 mm dia |
64 | 250 mm dia |
65 | 200 mm dia |
66 | Plenum Box Providing and fixing of factory / Site fabricated GI plenum box for supply air diffuser ( size : 450 x 450 x 300/400 ( H) mm |
67 | Providing and fixing of threaded GI fittings for Sprinkler |
68 | Thermal Insulation for drain pipes Providing and fixing ofclosedcellnitrilerubberthermalinsulationClass"O"forcondensate drain pipes . Material should be supplied in tube form. Make - APL/AFlex / Kflex /Armacell / Aerofoam 9 MM for Supply Air |
69 | Tube Axial Flow Fans Supply, Installation,testing and commissioning of approved make ofLong / short case Tube Axial fan complete with suitable motor(as the case may be, based on duty conditions and other requirements) , suitable for operating on 3 phase electric supply, 415+/-10% volts, 50 Hz cycles. The fan shall be complete with all accessories, including hanging arrangementsuitable for wall mounted / ceiling suspended , including vibration isolation (Spring type),The fan shall be supplied with a suitable 3 phase motor ( 960 / 1450 RPM) . The motor shall beclass Fin case of Fresh Air / pressurisation andclass-Hincase of exhaust / smoke Spill duty. All ventilation Fans and fan motors shall be suitably rated to handle high temperature (250 Deg C, as per BS-7346 Part-2 : 1090]) of smoke (class -H), . Motor shall be VFD compatible. Make : Airflow / Wolter / Kruger or equivalent |
70 | 3000 CFM Tube axial fan, 30 mm SP WG ( for smoke extraction) |
71 | 3500 CFM Tube axial fan, 30 mm SP WG ( for smoke extraction) |
72 | 4000 CFM Tube axial fan, 30 mm SP WG ( for smoke extraction) |
73 | 3000 CFM Tube axial fan, 30 mm SP WG ( for Replenishment Air ) |
74 | 3500 CFM Tube axial fan, 30 mm SP WG ( for Replenishment Air ) |
75 | 4000 CFM Tube axial fan, 30 mm SP WG ( for Replenishment Air ) |
76 | Inline fan Supply,installation,testing and commissioning of Inline fan of the following capacity of approved make and specification. |
77 | 400 CFM, 15 mm SP WGsuitable for 220±5% volts 50 Hz cycles, 1 phase AC supply. |
78 | 700 CFM, 15 mm SP WGsuitable for 220±5% volts 50 Hz cycles, 1 phase AC supply. |
79 | ELECTRICAL ACCESSORIES Supply, installation, testing and commissioning of wall / floor mounted type electricalpanelsincludingsystem control wiringwith incoming, outgoingfeeders as described below :- Supplyof wallmounted type electricalpanelsincludingsystem control wiringwith incoming, outgoingfeeders as described below :- Panel Accessories MAKE- ABB / Siemens / Schinder/ Legrand / L&T |
80 | Fan Panel -1 ( Smoke extraction - 4th floor ) Incoming 1 no. 50 amp 4P MCB Breaker ON/OFF/TRIP indicating lights. Digital voltmeter with SS with control fuses. Digital ammeter with SS and CT"s. Phase indicating lights with control fuses. 63 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves. Outgoings Breaker ON/OFF/TRIP indicating lights on each feeder ON/OFF Push Button with indication lights on each feeder Auto / Manual Switch for BMS integration on on each feeder 4 nos. 16 amp,TP MCB with SPPR( with DOL starter, 1.5 KW) 1 no. 10 Amp. DP MCB Panel as described above and in drawings. |
81 | Fan Panel -1 ( Smoke extraction - 5th floor ) Incoming 1 no. 63 amp 4P MCB Breaker ON/OFF/TRIP indicating lights. Digital voltmeter with SS with control fuses. Digital ammeter with SS and CT"s. Phase indicating lights with control fuses. 80 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves. Outgoings Breaker ON/OFF/TRIP indicating lights on each feeder ON/OFF Push Button with indication lights on each feeder Auto / Manual Switch for BMS integration on on each feeder 6 nos. 16 amp,TP MCB with SPPR( with DOL starter, 1.5 KW) 1 no. 10 Amp. DP MCB Panel as described above and in drawings. |
82 | Supply & laying of following grade with aluminium/Copper conductor armoured FIRE SURVIVAL cable with (EPR) Ethylene Propylene rubber insulation as per BS 7846:2009 & IEC-60502:2004 Part-1 (Armoured), Retain circuit integrity as per BS 6387 C.W.Z (armoured), BS-8491:2008, BS 8434-2: 2009 (armoured), (Resistance to fire at 950º C for 3 hours), as per specifications. Cost oftermination glands and GI earthing (flats / strips / wires, as may be applicable as per electric rules : Earthing system shall comply to IS: 3043-1987.), identification tags , clamps , and saddles shall be included. |
83 | 3C x 2.5 Sqmm Copper,make- Polycab, Havels, KEI |
84 | Supply, Installation testing and commissioning of zero leak back draft damper manufacturedfrom18GGIframe MAKE- Caryaire/Dynacraft/ Airflow/ Systemair / Uniaire/ Dynamic or equivalent |
85 | Following tests to be done by the contractor in 4th and 5th floor HVAC system to make the system fully functional:- 1. Light/ Smoke testing, 2 Air Balancing of entire 4th and 5th floor, testing , adjusting of entrie system with TESTO AIR CAPTURE HOOD with report, vibration and noise testing. 3.All 04 AHUs capacity test, CFM testing, Vibration testing, noise testing, water balancing. |
86 | Providing and fixing of aluminum fixed tye louver with bird screen for Somke fans |
87 | Providing and fixing of extruted aluminum air transfer grille |
88 | Return air "Z" shape piece Providing and fixing of factory / Site fabricated "Z" shape return air duct piece duly acoustically lined with 10 mm thick open cell nitirle rubber Class-1. |
89 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc as per site conditions. |
90 | Grills/ Diffusers SITC of Supplyairdiffusersofpowdercoatedaluminiumwithaluminiumvolume control Dampers with anti smudge ring & removable core. Standard size 595x595 (375X375 neck size) Rate only item. If number of diffusers increase at the the time of execution, vendor will be paid amount according to the additional measured quantity over BOQ quantity and will be paid as per mentioned rate |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy