Tender For Construction Of Evm/Vvpats Warehouse In The Campus Of Mini Sectt. At Narnaul (Pdg. Fire Alarm System, Water Cooler With Ro Cctv System And Air Conditioner), narnaul-Haryana

Public Works Department-PWD has published Tender For Construction Of Evm/Vvpats Warehouse In The Campus Of Mini Sectt. At Narnaul (Pdg. Fire Alarm System, Water Cooler With Ro Cctv System And Air Conditioner). Submission Date for this Tender is 05-01-2024. Godown Tenders in narnaul Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

41315297
Tender For Construction Of Evm/Vvpats Warehouse In The Campus Of Mini Sectt. At Narnaul (Pdg. Fire Alarm System, Water Cooler With Ro Cctv System And Air Conditioner)
Open Tender
Indian
Haryana
narnaul
05-01-2024

Tender Details

Construction Of Evm / Vvpats Warehouse In The Campus Of Mini Sectt. At Narnaul ( Pdg. Fire Alarm System, Water Cooler With Ro Cctv System And Air Conditioner )

Key Value

Document Fees
INR 500 /-
EMD
INR 9938.0 /-
Tender Value
INR 4.96 Lakhs /-

BOQ Items

Name of Work: Construction of EVM/VVPATs warehouse in the campus of Mini Sectt. at Narnaul (Pdg. Fire Alarm system, water cooler with RO CCTV System and Air Conditioner) (Rs. 15.45 Lac) (Pdg. Fire Alarm System only)
Sl. No. Item Description
1[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
2Supply Installation Testing Commissioning of addressable Heat Detector with fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletrmagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panel-current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector. Make: Bosch FAH-440 plus FAA-440, Siemensr Cerberus HI921 plus DB-11, Honeywell Morley MI-RHSE plus B501.
3Supply Installation Testing Commissioning of UL/EN54/LPCB listed and FM approved line isolator for isolation the section of circuit in case of short in the addressable loop wiring Make: Bosch / Siemens Cerberus/ Morley.
4SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with Back Box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make:Honeywell /Bosch /Siemens.
5SITC of Addressable Loop Powered Sounder with Strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.Make:Honeywell/Bosch/Siemens.
6SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including zost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work .Make GLOLITE / PES / OMEX.
7Supply Installation Testing Commissioning ofAddressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall beEN54/UL/VDS CertificationMakes :Bosch /Siemens Cerberus / Morley.
8SITC of Addressable Monitor Modulesfor monitoring of line with EOL resisteor/Potentialfree contact/voltage moitoring shall be EN54/UL/VDS approved. ( In case of 2 monioring features in one module (points) each points shall be consider separtely for payment).Makes: Bosch- FLM - 325 - 214, Siemens cerberus HTRI-M,Morley MI-DMMI.
9Supply Installation Testing Commissioning of minimum 1000 Mtr. Range Siren genertor provided at the roof of building with separate power supply, relay etc with all accessories required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make:- Kheraj / National.
10SITC of PVC unsheathed s/c stranded (ISI Marked) copper conductor cable 1100v grade in exising Pipe excluding the cost and errection of pipe but including connection etc with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make:- Havell`s / Polycab / Fenolex ( i )1.5sqmm fire cable single core
11Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire). ABC Dry Powder extinguisher 6 Kg Capacity.
12Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire). CO2 type 4.5 Kg Capacity.
13SITC of Water CO2 9Ltr Cap ISI Marked (Safex / Minimax / Ajax)
14SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\ shall have a built in power supply and battery charger maintenance free 24 AH 2x12 W SMF LEDbattery capable of running for a minimum24 hours withbattery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specification complete in all respect upto entire satisfaction of engineer incharge of work .Make:Honeywell Marlay DXE series /Bosch FPA 1000 series/ Cerberus by Siemens
15SITC of addressable multisensor detector with a combination of Opticaland Thermalincluding mounting base, auto addressing feauture asrequired.Detetctor should have 2as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices). Makes: Bosch FAP-440-T plus FAA-440, Siemens Cerberus OH921 plus DB-11, Honeywell Morley MI-PTSE plus B501
Disclaimer :