Tender For Special Repair To Bldg No T-2 & T-3 Under Age B/R-Iiat Itarana Cantt Alwar, alwar-Rajasthan

Military Engineer Services-MES has published Tender For Special Repair To Bldg No T-2 & T-3 Under Age B/R-Iiat Itarana Cantt Alwar. Submission Date for this Tender is 22-01-2024. Building Work Tenders in alwar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

41263433
Corrigendum : Tender For Special Repair To Bldg No T-2 & T-3 Under Age B/R-Iiat Itarana Cantt Alwar
Open Tender
Indian
Rajasthan
alwar
22-01-2024

Tender Details

Tender For Special Repair To Bldg No T-2 & T-3 Under Age B / R-Iiat Itarana Cantt Alwar ; 1 Demolition Cement Concrete ( Unreinfored ) As In Ground Floor And Paving Not Exceeding 15Cm Thick Below Or Above The Ground Level Complete All As Specified & Directed. 2 Demolition Of Brick / Stone Masonry Work Built In Cement Mortar Or Cement Lime Mortar Including All Quion Arches Complete All As Specified & Directed. 3 Taking Down Chowkhat With Shutter Without Taking Off Shutte From The Frame Exc 1.5 Sqmand Not Exc 4 Sqm Each Complete All As Specified & Directed. 4 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters Frome The Frames ) N Exc 1.5 But Each Complete All As Specified & Directed. 5 Dismantling Of Concrete Post As In Roof Truss / Puline Etc Any Section In Any Description And Making Good In Disturbed Portion Complete All As Specified & Directed. 6 Dismantling Ac / Cgi / Fibre Sheet ( Corrugated, Semi Corrugated Etc ) As In Rooof Etc Complete As As Specified 7 Excavation In Post Holes ( Soft / Loose Soil ) Each N.Exc.0.5 Cum, Getting Out, Rfr In And Ramming Earth Or Broken Rubble Mixed Wth Earth Around In Layers Not Exceeding 25 Cm, Watering, And Removing Surplus Soil To A Distance N.Exc. 50M Complete All As Specified & Directed. 8 M&L Pcc ( 1:3:6 ) Type C-2, Using 40 Mm Graded Stone Aggregate In Foundation Filling / Mass Concrete As In Post Hole Complete All As Specified & Directed. 9 S&F For Structural Steelas In Trusses , Pulines, Raftermade Of Hallow / Square / Rectangle / Roundsection Including Necessary Tee, Angle, Cleats Including Necessary Cutting Welding Notching Complete All As Specified And Directed 10 S&F For Structural Steelas In As In Vertical Member Made Of Hallow / Square / Rectangle / Roundsection Including Necessary Tee, Angle, Cleats Including Necessary Cutting Welding Notching Complete All As Specified And Directed 11 S&F Plates ( Plain Or Chequered ) Chanels Square Cut Or Notched ( Ordinary And Counter Sunk ) Forming Holes, Without Any Attachment Complete All As Specified & Directed. 12 S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified And Directed. 13 S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet Reday Made Ridge Suitable For Corrugated Sheet 0.50 Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa With Self Tapping Screws As Specified And Directed. 14 M&L For Cutting Holes In Stone Walls Built In Cement Mortar For Inserting Hold Fasts And Making Good Dismantled Portion In Cement Mortar 1:3, Exc Half Brick & Not Nec One Brick ( Depth Of Embedded Portion Of Hold Fasts Or Lungs Measured From The Face Of The Jamb Into The Wall ) Complete All As Specified & Directed. 15 M&L Pcc 1:2:4 Type B1 ( Using 20Mm Graded Aggregate ) To Fill The Gap Between Roof Sheet And Wall, Both Outer Side And Inner Sidecomplete All As Specified And Directed. 16 Dismantling Wall And Any Type Of Ceiling Boards ( Fibre, Pulp, Insulation Etc ) Or Insulation Boards / Slabs / Blankets Any Thickness Fixed To Any Type Of Frame Including Cover Fillets Complete All As Specified. 17 M&L For Suspendedfalse Ceiling System Using 4 Mm ThickE Board Ceiling Tiles Classic / Designer As Approved By Ge Of Size 595 X 595Mm ( As Approved By Ge ) Fixed With And Including Galvanized Iron Powder Coated Gi Grid System Suspendedfrom Ceiling With Provision Of Galvanized Wire 4 Mm Dia With Butterfly Clips And Wall Taping Screw I, Hold Down Clips For Fixing The Board To Frame Complete All As Per Manufacturer’S Instructions, Complete, All As Directed And Specified. ( A ) Size Of Grid - 600 X 600 Mm. ( B ) Size Of Main Tee – 39 X 24 ( C ) Size Of Cross Tee – 29X34 ( D ) Size Of Wall Angle – 22.20 X 22.20 18 S&F Granite ( Of Any Type ) Work20mm Thick ( Table Rubbed And Polished ) In Steps, Jambs, Pillars , Window Cills, Cooking Platforms And Like ( Including Cutting For Fixing Of Whb, Sink Etc ) In Cement Mortar ( 1:4 ) Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Complete All As Specified And Directed. 19 M&L Vitrified Tiles ( Light Shade ) 9 To 10Mm Thick Of Size 600Mmx600mmas In Floorset And Jointed In Neat Cement Slurry And Pointed In White. / Colour Cement To Match The Shed Over And Including 15Mm Thick Cement Morter Screed Bed 1:6 Complete All As Specified And Directed 20 All As Per Ser Item No 19.00 But In Skirting And Dado Including 10Mm Thick Rendering Cement Mortar 1:4. 21 M&L Non Skid Ceramic Colour Tiles 7 To 8Mm Thickarea Of Each Tiles Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm Set And Jointed In Neat Cement Slurry In Floor And Pointed In Colour Cement To Match The Sade Of Tiles Including Sceed Bed Or Bedding Layer Of Mortar 15 Mm Thik 1:6 Complete All As Specified And As Directed 22 All As Per Ser Item No 21.00 But As In Skirting Includinf Cm 1:4 10M Thick 23 M&L Walling Of Random Rubble, Uncoursed , Well Bonded Bedded And Solidly Hearted, Built In Cm 1:4 Compleete All As Specified And Directed 24 All As Per Ser Item No 23.00 But Except Stone ( Old Stoneto Be Re Used In This Items ) 25 Racking Out Joint From Random Rubble Masonry Brought Up To Uncourse Complete All As Specified & Directed. 26 Taking Down Cement Plaster In Any Description Including Racking Out Joints And Hacking For Key Scrubbing Down With Water Complete All As Specified And Directed 27 M&L15mm Thick Rendering In Cement Mortar 1:4 On Other Than Fair Faces Of Brstone Masonrysurace Rendering Is To Be Even And Smooth With Out Using Extra Cenent Complete All As Specified And Directed 28 M&L15mm Thick Rendering In Cement Mortar 1:6 Onfair Faces Of Brick Work Surace Rendering Is To Be Even And Smooth With Out Using Extra Cenent Complete All As Specified And Directed 29 M&L For Rough Cast Plaster On Exterior Wallsapplying The Under Coat Of Cement And Sand Morrtar 1:3 Not Less Than 10Mm Thick And While It Is Still In Plastic State The Roughcast Mixture Consisting Of Crushed Stone Or Fine Gravel Aggregate ( Size Between 6 To 12Mm ) Mixed With Coarse Sand And Cement In The Raio Of 1:1:1 Shall Be Applied And Finished Even.The Mix Of Cement And Sand Shall Made Slightly Wetter Than Normal For Rendering To Ensure That Larger Aggregate Are Thoroughly Covered Completeall As Specified And Directed By Engineer In Charge 30 M&L 50Mm Thick Cement Concrete 1:3:6Type C2 ( Using 40Mm Graded Crushed Stone Aggregate ) As In Plinth Protection Path Laid In Panel Surface Finished Even And Fair With Outusing Extra Cement Including Filling The 6Mm Wide Joints Shall Be Laid Between Panels And Junction Of Wall.The Joints Shall Be Filled With Bitumenous Masic ( 1:3 ) 1 Part Of Cement And 3 Part Ofsandcomplete All As Specified And As Directed 31 M&L Chequered Cement Concrete ( Coloured ) Tiles 30Cmx30cm X25mm Thick With ( Lacquer / Glossyfinish ) Set And Jointed In Net Cement Slurry In Floor And Pointed With Grey Cement And Pimentincluding Cement Mortar Screed Bed 1:4, 20Mm Thick Complete All As Specified And Directed 32 M&L Preparation Of Newly Plasterd Surface Of Wall And Applying Two Coats White Oild Bound Distemper Over A Coat Of Layer Ofwall Care Putty Complete All As Specified And Directed 33 M&L Preparation Of Newly Plasterd Surface Of Wall And Applying Two Coats Cement Base Paint Over A Coat Of Primer Complete All As Specified And Dircted 34 M&Lcomplete Removal Of Old Exiting Surface By Washing Rubbing Of Wall And Applying One Coat Cement Base Paint Over A Coat Of Primer Complete All As Specified And Dircted 35 M&L For Complete Removal Of Existing Treatment Including Cleaning Of Mortar Drops, Smoke Soot, Moulds, Moss, Efforsecent Salt, Trading Oil Grees Spots Etc Using Grinding Machine On Wall Surfaces And Preparation Of Old Plastered Wall Surfaces And Applying Two Coats Of Oil Emulsion Distemper ( Obd ) Of Approved Shed / Tint Over And Including A Coat Of White Wall Care Putty2 Mm Thick Complete.Over A Coat Of Primer . 36 S&F Powder Coated Aluinium Dooranodised Of Approved Colour ( Size Of Frame :63.5Mx38.10Mmx2mm Thick & Size Of Shutter :Door Vertical ( Style ) With Gasket Of Size 46.3Mmx45.00Mmx 1.50Mm Thick, Top Rail Of Size 47.00Mmx45.00Mmx1.30Mmlock Rail / Middle Rail 83.00Mmx44.50Mmx1.65Mm Thickbottom Rail 114.3Mmx45.00Mmx1.50Mm Thick Including S&F Of4.8 Mm Thicksheet Glass Withglazing Clip, Pvc Track Gasket , Epdm Rubber Gasket On Glass Of Weather Tightening Alongwith Recessed Type Handle, Hingees, Mortic Lock, Door Closer Complete All As Specified As Per Td -2004 / 61R Sheet No 1 / 1 37 S&F Powder Coated Aluinium Window Having Three Track Section 92Mmx31.75M Shutter Section 40Mmx18mm Mounted On Bearing To Slide On Track Plain Anodised Of Approved Colour Including S&F Of5 Mm Thick Frosted / Plain Glass And Wire Mesh With Glazing Clip, Pvc Track Gasket , Epdm Rubber Gasket On Glass Of Weather Tightening Alongwith Recessed Type Handle And Lock Including Sealing Gap With Marble / Granite Surfacewith Silicon Sealent Aking It Water Proof In All Mannerincluding Aluminium Grill Complete All As Specified And Directed By Engineer In Charge . 38 S&F Decorative Ultra Slim Liner Led Lighting Fixture With Extruded Polycarbonate, Environmental Friendly, Energy Efficient Suitable For 16 Watt To 20 Watt With Led Tube Of Model E-Lite Led Pride Plus And Connecting Up With And Including Three Core, Pvc Insulated, Sheathed Copper Conductore Cable Of Required Size And Length From Ceiling Rose To Fitting Complete All As Specified & Directed.Make :- Havells Cat Part No Lhexbhp71nw018 Or Equivalent Of Philips / Crompton Greaves / Bajaj / Wipro. 39 Excavation In Trenches N.Exc 1.5M Wide And N.Exc 1.5M In Depth For Foundation And Getting Out In Soft / Loose Soil All As Specified And Directed. 40 Removing Excavated Material N.Exc 50M And Depositing Where Directed At A Level N.Exc 1.5M Above The Starting Point. 41 Returning Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers N.Exc. 25Cm Deep As In Soft / Loosesoil Copletete All As Specified. 42 S&F Pvc White Cover Plate With Frame 1 Module 43 S&F Pvc White Cover Plate With Frame 2 Module 44 S&F Pvc White Cover Plate With Frame 3 Module 45 S&F Pvc White Cover Plate With Frame 4 Module 46 S&F Pvc White Cover Plate With Frame 6 Module 47 S&F Pvc White Cover Plate With Frame 8 Module 48 S&F Modular Metal Flush Box 1 Module 49 S&F Modular Metal Flush Box 2 Module 50 S&F Modular Metal Flush Box 3 Module 51 S&F Modular Metal Flush Box 4 Module 52 S&F Modular Metal Flush Box 6 Module 53 S&F Modular Metal Flush Box 8 Module 54 Taking Down Carefully Copper / Aluminium Point Wiring For One Light / Socket / Power Point And Taking Down Of Teak Wood Batten / Pvc Casing Caping And Making Good Disturbed Surfaces Of Walls / Ceiling / Floors Etc Including Dismentling Of Fittings. 55 M&L For Point Wiring For One Light Point Controlled By One, One Way Switch With 1.50 Sqmm Two Single Core Pvc Insulated And Unsheathed Multistranded Copper Conductor Frls Cable 1100 Volt Grade Including 1.50 Sqmm Single Core Pvc Insulated And Unsheathed Multistranded Copper Conductor Frls Cable 1100 Volt Grade As Continuous Earth Wire In Green Colour To Common Earth And Connected To Earth Dolly Laid / Drawn Into And Including Pvc Casing & Caping With Accessories Fixed On Surface Of Walls / Ceiling By Means Of Pvc Sleeves / Dash Fasteners With Cadmium Plated Screws, All As Per Is And Including Wooden Boxes Fixed On Wall With And Including 3Mm Thick Phenolic Laminated Sheet Top Cover For Mounting Switches, Sockets, Fan Regulators Etc Complete All As Specified. 56 All As Per Serial Item No 55.00 Here-In-Before But For One Fan / Ceiling Fan Point Controlled By One Switch And Regulator. 57 All As Per Serial Item No 55.00 Here-In-Before But For One Bell Buzzer Point Controlled By One Switch And Regulator. 58 All As Per Serial Item No 55.00 Here-In-Before But For One 3 Pin 5 / 6 Amp Socket Outlet Controlled By One 5 Amp Switch On Same Board. 59 All As Per Serial Item No 55.00 Here-In-Before But For One 3 Pin 5 / 6 Amp Socket Outlet Controlled By One 5 Amp Switch On Independent Board. 60 All As Per Serial Item No 55.00 Here-In-Before But For One Light Point Controlled By Two, Two Way Switches. 61 All As Per Serial Item No 55.00 Here-In-Before But For One 3 Pin Socket Outlet 15 / 16 Amps Controlledby One 15 / 16 Amps Switch On Independent Board With 2.50 Sqmm Two Single Core Pvc Insulated And Unsheathed Multistranded Copper Conductor Frls Cable 1100 Volt Grade Including 2.50 Sqmm Single Core Pvc Insulated And Unsheathed Multistranded Copper Conductor Frls Cable 1100 Volt Grade As Continuous Earth Wire In Green Colour. 62 All As Per Serial Item No 55.00 Here-In-Before But For One 3 Pin Socket Outlet 15 / 16 Amps Controlledby One 15 / 16 Amps Switch On Independent Board With 4.00 Sqmm Two Single Core Pvc Insulated And Unsheathed Multistranded Copper Conductor Frls Cable 1100 Volt Grade Including 4.00 Sqmm Single Core Pvc Insulated And Unsheathed Multistranded Copper Conductor Frls Cable 1100 Volt Grade As Continuous Earth Wire In Green Colour. 63 S&F Switch Piano Flush Type, Single Pole, One Way, 5 / 6 Amp, 250 Volts Module Typecomplete All As Specified And Directed. 64 S&F Switch Piano Flush Type, Single Pole, One Way, 15 Amp, 250 Volts Module Typecomplete All As Specified And Directed. 65 Supply And Fixing Sheet Metal Enclosuressingle Door Type Suitable For Fixing McbS, Spn With 200 Amps Rated Bus Bar, 2 Way, 240 Volts. 66 S&F Ac Box Signle Plie And Neutral Elcolsure With A Two Pin And Socket Complete With One Single Pole Mcb 240 Volts, 32 Amps 67 S&F Switch Piano Flush Type, Single Pole, Two Way, 5 Amp, 230 Volts Module Type Complete All As Specified And Directed. 68 S&F Socket Outlet For 3 Pin ( With 2 Pin Outlet Also ) , 5 / 6 Amp, Flush Type 240 Voltmodule Type Complete All As Specified And Directed. 69 S&F Socket Outlet For 2 In 1, 3 Pin 5 & 15 Amp, Flush Type 240 Volt Module Type Complete All As Specified And Directed. 70 S&Fmodular Bell Push , 5 Amp 240 Volts Complete All As Specified And Directed. 71 S&F Bell / Buzzer Ac 230 Volts Single Pole Complete All As Specified And Directed. 72 S&F Ceiling Rose Surface Bakelite 65X50mm Two Or Three Terminals Complete All As Specified And Directed. 73 S&F Led 16 Watt Ultra Slim Edge 2X2 Feet Lit Panel In Aluminium Casing Recess Mounted Square Fixture In White Finsh Suitable For Low Ceiling Height, 3 In 1 , 3K, 4K, 6Kwith & Including Led Previred And Connecting Up Dismantling Of Old Unsv Recessed Mounted Light.Make : Havells Cat Part No Lhexbhp71nw018or Equivalent Of Philips / Crompton Greaves / Bajaj / Wipro. 74 S&F In Repair Adore Led Lamp 9 / 10 Watt Complete All As Specified And Directed. Make : HavellS / Crompton / Syska. 75 Supply And Fixing Adore Led Lamp Of 9 / 10 Watt Including Taking Down Old U / S Cfl Lamp Complete All As Specified & Directed. Make :- Havells Cat Part No. Lhlderheml8x010or Equivalent Of Philips / Crompton Greaves / Wipro / Bajaj 76 S&F Stepped Type Electronic Fan Regulator, Module Type And Connecting Up Isi Marked 240 Volts Complete All As Specified & Directed. 77 S&F Sheet Metal Enclosures, Double Door Type, Suitable For Fixing Mcb Spn With 200 Amps Rated Bus Bar, 8 Way, 240 Volts Complete All As Specified And Directed. 78 Supply And Fixing Sheet Metal Enclosuressingle Door Type Suitable For Fixing McbS, Spn With 200 Amps Rated Bus Bar, 4 Way, 240 Volts. 79 S&F Mcb 63 Amps, Single Pole & Neutral, 240 Volts Complete All As Specified And Directed. Make : Legrand / Havells / Abb 80 S&F Mcb 32 Amps, Single Pole & Neutral, 240 Volts Complete All As Specified And Directed. Make : Legrand / Havells / Abb 81 S&F Mcb 6-32 Amps, Single Pole, 240 Volts C Curve, 10Ka, Isi Marked As Per Is / Iec 60898-1 2002 Complete All As Specified And Directed. Make : Legrand / Havells / Abb 82 S&F Sub Main Wiring On Including Passing Throuh Pvc Conduit Pipe 1100 Volts Grade With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 6 Sqmm And Continuous Earth With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm Of Green Colour Confirming To Is 694 / 1990 Including Taking Down Existing Unserviceable Sub Main Wiring. ( Note : Two Runs Of Cable With One Run Of Earth Wire And One Run Of Pvc Casing Caping Should Measured As One Length ) . 83 Supply, Laying, Jointing And Testing Xlpe Insulated, Armoured, Heavy Duty Lt Underground Electric Cable With Stranded Aluminium Conductor 1100 Volts Grade Cross Sectional Area 50 Sqmm 3.5 Core Laid In Trenches, Along Poles Through Pipes Etc Complete All As Specified & As Directed.Note : ( I ) Sand Cushioning, Cable Protection, Gi Protection Pipe, Clamps, Jointing Kits And Excavation & Earth Work Shall Be Measured & Paid For Separately Including Taking Down Old Unserviceable Xlpe Cable. ( Ii ) Road Cutting / Floor Cutting / Cutting Holes Etc In Walls Required For Laying / Fixing Of Cable Etc Shall Be Made Good As Per Existing. Nothing Extra Shall Be Admissible On This Account. Quoted Rates Shall Be Inclusive Of The Above Provisions. 84 M&L For Brick Work With Fly Ash Bricks { As Per Is-13757 ( 1993 ) Burnt Clay Fly Ash Building Bricks } , ( Old Size Bricks ) With Width Equal To The Length Of The Brick Laid Dry & Flat Abutted With Each Other With Gap Between Adjacent Bricks Not Exc 10 Mm Over Ug Cable For Protection Complete All As Specified & Directed. 85 M&L Dry Sand ( Tibba Sand ) And Punning For Cushioning To Under Ground Cable All As Directed. Note :- For The Purpose Of Payment Only Punned Thickness Shall Be Measured. 86 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick Burried Directly In Ground ( Earth Pit Not Less Than 2.25 M Deep Below Ground Level ) With Top Edge Of Plate Not Less Than 1.5 M Deep Below Normal Ground Level And Connected To And Including Galvanized Iron Earth Wire 4 Mm Dia By Means Of Gi Nuts, Bolts, Check Nuts, Washers Thimbles, Etc As Shown In Electrical Plate No 3 Of Ssr Part-I And Connection To Main Switch Board / Test Point / Panel / Equipment And Testing On Including Excavation And Earth Work In Any Type Of Soil, Returning Filling In, And Removal Of Surplus Spoil To A Distance Not Exc 50 Metre, Charcoal And Salt In Alternate Layer 15 Cm Thick All Around The Earth Plate Electrode, Ms Funnel With Wire Mesh, Gi Pipe Medium Grade 20 Mm Bore For Watering And 15 Mm Bore 3.00 Metre Long Gi Pipe Light Grade For Earth Wire Protection Fixed With Poles With Two Clamps, Made From Ms Flat 25 Mmx3mm, Bolts, Nuts And Washers, Pccchamber ( 1:3:6 ) Type C1, 40Mm Thick Precast Rcc Cover 1:2:4 Type B1 Shall Be Provided On Ci Frame Etc Complete All As Specified & As Directed. 87 Taking Down & Refixing Of Ceiling Fan Complete Of Any Sweep 240V, Ac And Connecting Up With Necessary Wiring Of 3 Core Flexble Copper Wire, Complete All As Specified And Directed. 88 Boring Of Holes Under Road, Payment Hard Standing By Trench Less Technology Unsing Ultra Sound Technique And Necessary Amchine Including Supply And Fixing Hpde Pipe Of 80Mm Bore Suitable For 0.4 Mpa Working Pressure All As Specified And Directed 89 S&F Led Type Street Draco Series Light Luminaire 20 Watt 230 V 50 Hz Including All Necessary Fitting Accessories And Led Complete All Directed. Make :- C&S Cat Part No Ltess Wled Or Equvalent Crompton Freaves / Wipro 90 S&F Cubical Metallic Box Of Size 1.0 Mtr X 0.9 Mtr X 0.30 M Depth Made Out Of 2 Mm Thick Mild Steel Sheet, Fron Openable Double Door Type With Locking Arrangment With And Including 3 Mm Tgick Plain Sheet Clear Glass Of Suitable Size Fixed To Facilite Meter Reading, All Internal And External Steel Surfaces Painted Wityh Two Costs Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Internal Wiring With Pvc Insulated Single Core Multistranded Copper Conductor Frls Cable Is-694 Marked Of Adequate Size But Not Less Than 6 Sq Mm With Proper Ferrule And Cable Gland, Box Shall Be Fixed On Wall With Anchor Type / Fastner Type Bolts & Nuts ( Set Of 6 Bolts Of 12 Mm Dia 200Mm Long With Nuts And Washer ) Frouted Into The Wall Properly To Hold The Box, Writing Mes / Qtr No For Each Energy Meter With Thick Whit Synthetic Enamel Paint, Neoprene Rubber Gasket Shall Be Provided For Proper Sealing, Including Bos Shall Have Arrangement For Fixing Electric Energy Meter- 04 Nos, Mcb Db Spn 2 Way -04 Nos, Mcb Db Spn 4 Way -01 Nos Complete All As Dirtected. Note :- ( A ) Existing Electric Meter -04 Nos Will Be Taking Doen Carefully And Refixing The Same Inside The New Meter Box Carefully Incl Necessary Electric Connections And Sealing The Elcectric Meter, And Mcb Db Spn 4 Way And Mcb Db Spn 2 Way Shall Be Measured And Paid For Separately Under Relevent Items Of This Dchedule. ( B ) The Cubical Box Shall Be Fix Inside ( Concelled ) The Existing Wall By Necessary Cutting / Frouting The Wall And Make Good The Distrubed Surfaces Be Applying Cement.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jan-2024 Corrigendum No 1 BOQ 15-01-2024
2 13-Jan-2024 Extension of dates Date 22-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 77500.0 /-
Tender Value
INR 38.74 Lakhs /-

BOQ Items

Name of Work :SPL REPAIR TO BLDG NO T-2 & T-3 UNDER AGE B/R-II AT ITARANA CANTT ALWAR
Sl. No. Item Description
1Demolition cement concrete(unreinfored) as in ground floor and paving not exceeding 15cm thick below or above the ground level complete all as specified & directed.
2Demolition of brick/Stone masonry work built in cement mortar or cement lime mortar including all quion arches complete all as specified & directed.
3Taking down chowkhat with shutter without taking off shutte from the frame exc 1.5 Sqmand not exc 4 Sqm each complete all as specified & directed.
4Taking down chowkats or frames with shutters (without taking off shutters frome the frames) n exc 1.5 but each complete all as specified & directed.
5Dismantling of concrete post as in Roof truss/puline etc any section in any description and making good in disturbed portion complete all as specified & directed.
6Dismantling AC/CGI/Fibre sheet (Corrugated,Semi corrugated etc) as in rooof etc complete as as specified
7Excavation in post holes (soft/loose soil) each n.exc.0.5 cum, getting out, RFR in and ramming earth or broken rubble mixed wth earth around in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc. 50m complete all as specified & directed.
8M&L PCC (1:3:6) type C-2, using 40 mm graded stone aggregate in foundation filling /mass concrete as in post hole complete all as specified & directed.
9S&F for structural steelas in Trusses , pulines,raftermade of Hallow /square/rectangle/roundsection including necessary tee, angle, cleats including necessary cutting welding notching complete all as specified and directed
10S&F for structural steelas in as in vertical member made of Hallow /square/rectangle/roundsection including necessary tee, angle, cleats including necessary cutting welding notching complete all as specified and directed
11S&F plates (Plain or chequered ) Chanels square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified & directed.
12S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
13S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet reday made ridge suitable for corrugated sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa with self tapping screws as specified and directed.
14M&L for cutting holes in stone walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3, exc half brick & not nec one brick (Depth of embedded portion of hold fasts or lungs measured from the face of the jamb into the wall) complete all as specified & directed.
15M&L PCC 1:2:4 type B1 (using 20mm graded aggregate ) to fill the gap between roof sheet and wall,both outer side and inner sidecomplete all as specified and directed.
16Dismantling wall and any type of ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness fixed to any type of frame including cover fillets complete all as specified.
17M&L for suspendedfalse ceiling system using 4 mm thick"E" Board ceiling tiles classic/ designer as approved by GE of size 595 x 595mm (as approved by GE) fixed with and including galvanized iron powder coated GI Grid system suspendedfrom ceiling with provision of galvanized wire 4 mm dia with butterfly clips and wall taping screw i, hold down clips for fixing the board to frame complete all as per manufacturer’s instructions, complete, all as directed and specified. (a)Size of grid - 600 x 600 mm. (b)Size of main Tee – 39 x 24 (c)Size of cross Tee – 29X34 (d)Size of wall angle – 22.20 x 22.20
18S&F Granite(of any type )work20mm thick (table rubbed and polished)in steps, jambs, pillars ,window cills,cooking platforms and like (including cutting for fixing of WHB, Sink etc) in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
19M&L vitrified tiles (light shade) 9 to 10mm thick of size 600mmx600mmas in floorset and jointed in neat cement slurry and pointed in white./ colour cement to match the shed over and including 15mm thick cement morter screed bed 1:6 complete all as specified and directed
20All as per ser item No 19.00 but in skirting and dado including 10mm thick rendering cement mortar 1:4.
21M&L non skid ceramic colour tiles 7 to 8mm thickarea of each tiles exceeding 0.11 Sqm but not exceeding 0.18 sqm set and jointed in neat cement slurry in floor and pointed in colour cement to match the sade of tiles including sceed bed or bedding layer of mortar 15 mm thik 1:6 complete all as specified and as directed
22All as per ser item No 21.00 but as in skirting includinf CM 1:4 10m thick
23M&L walling of random rubble, uncoursed , well bonded bedded and solidly hearted, built in CM 1:4 compleete all as specified and directed
24All as per ser item No 23.00 but except stone(old stoneto be re used in this items)
25Racking out joint from random rubble masonry brought up to uncourse complete all as specified & directed.
26Taking down cement plaster in any description including racking out joints and hacking for key scrubbing down with water complete all as specified and directed
27M&L15mm thick rendering in cement mortar 1:4 on other than fair faces of brstone masonrysurace rendering is to be even and smooth with out using extra cenent complete all as specified and directed
28M&L15mm thick rendering in cement mortar 1:6 onfair faces of brick work surace rendering is to be even and smooth with out using extra cenent complete all as specified and directed
29M&L for Rough cast plaster on exterior wallsapplying the under coat of cement and sand morrtar 1:3 not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm ) mixed with coarse sand and cement in the raio of 1:1:1 shall be applied and finished even.The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered completeall as specified and directed by Engineer in Charge
30M&L 50mm thick cement concrete 1:3:6type C2 (using 40mm graded crushed stone aggregate) as in plinth protection path laid in panel surface finished even and fair with outusing extra cement including filling the 6mm wide joints shall be laid between panels and junction of wall.The joints shall be filled with Bitumenous masic (1:3) 1 part of cement and 3 part ofsandcomplete all as specified and as directed
31M&L chequered cement concrete (coloured) tiles 30cmx30cm x25mm thick with (Lacquer/glossyfinish)set and jointed in net cement slurry in floor and pointed with grey cement and pimentincluding cement mortar screed bed 1:4, 20mm thick complete all as specified and directed
32M&L preparation of newly plasterd surface of wall and applying two coats white oild bound distemper over a coat of layer ofwall care putty complete all as specified and directed
33M&L preparation of newly plasterd surface of wall and applying two coats cement base paint over a coat of primer complete all as specified and dircted
34M&Lcomplete removal of old exiting surface by washing rubbing of wall and applying one coat cement base paint over a coat of primer complete all as specified and dircted
35M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efforsecent salt, trading oil grees spots etc using grinding machine on wall surfaces and preparation of old plastered wall surfaces and applying two coats of oil emulsion distemper( OBD) of approved shed/tint over and including a coat of white wall care putty2 mm thick complete.over a coat of primer .
36S&F powder coated aluinium dooranodised of approved colour( size of frame :63.5mx38.10mmx2mm thick & size of shutter :door vertical (style ) with gasket of size 46.3mmx45.00mmx 1.50mm thick, top rail of size 47.00mmx45.00mmx1.30mmlock rail/middle rail 83.00mmx44.50mmx1.65mm thickbottom rail 114.3mmx45.00mmx1.50mm thick including S&F of4.8 mm thicksheet glass withglazing clip, pvc track gasket ,EPDM rubber gasket on glass of weather tightening alongwith recessed type handle,hingees, mortic lock, door closer complete all as specified as per TD -2004/61R sheet No 1/1
37S&F powder coated aluinium window having three track section 92mmx31.75m shutter section 40mmx18mm mounted on bearing to slide on track plain anodised of approved colour including S&F of5 mm thick frosted/plain glass and wire mesh with glazing clip, pvc track gasket ,EPDM rubber gasket on glass of weather tightening alongwith recessed type handle and lock including sealing gap with marble /granite surfacewith silicon sealent aking it water proof in all mannerincluding aluminium grill complete all as specified and directed by Engineer in Charge .
38S&F decorative ultra slim liner LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for 16 Watt to 20 Watt with LED tube of model E-LITE LED Pride Plus and connecting up with and including three core, PVC insulated, sheathed copper conductore cable of required size and length from ceiling rose to fitting complete all as specified & directed.Make :- Havells Cat Part No LHEXBHP71NW018 or equivalent of Philips/ Crompton Greaves /Bajaj/Wipro.
39Excavation in trenches n.exc 1.5M wide and n.exc 1.5M in depth for foundation and getting out in soft/loose soil all as specified and directed.
40Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
41Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25cm deep as in soft/loosesoil copletete all as specified.
42S&F PVC white cover plate with frame 1 Module
43S&F PVC white cover plate with frame 2 Module
44S&F PVC white cover plate with frame 3 Module
45S&F PVC white cover plate with frame 4 Module
46S&F PVC white cover plate with frame 6 Module
47S&F PVC white cover plate with frame 8 Module
48S&F modular metal flush box 1 Module
49S&F modular metal flush box 2 Module
50S&F modular metal flush box 3 Module
51S&F modular metal flush box 4 Module
52S&F modular metal flush box 6 Module
53S&F modular metal flush box 8 Module
54Taking down carefully copper/aluminium point wiring for one light/socket/power point and taking down of teak wood batten/ PVC casing caping and making good disturbed surfaces of walls/ ceiling/ floors etc including dismentling of fittings.
55M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS and including wooden boxes fixed on wall with and including 3mm thick phenolic laminated sheet top cover for mounting switches, sockets, fan regulators etc complete all as specified.
56All as per serial item No 55.00 here-in-before but for one fan/ceiling fan point controlled by one switch and regulator.
57All as per serial item No 55.00 here-in-before but for one bell buzzer point controlled by one switch and regulator.
58All as per serial item No 55.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
59All as per serial item No 55.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
60All as per serial item No 55.00 here-in-before but for one light point controlled by two, two way switches.
61All as per serial item No 55.00 here-in-before but for one 3 pin socket outlet 15/16 Amps controlledby one 15/16 Amps switch on independent board with 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
62All as per serial item No 55.00 here-in-before but for one 3 pin socket outlet 15/16 Amps controlledby one 15/16 Amps switch on independent board with 4.00 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
63S&F switch piano flush type, single pole, one way, 5/6 Amp, 250 Volts module typecomplete all as specified and directed.
64S&F switch piano flush type, single pole, one way, 15 Amp, 250 Volts module typecomplete all as specified and directed.
65Supply and fixing sheet metal enclosuressingle door type suitable for fixing MCB"s, SPN with 200 Amps rated bus bar,2 way, 240 Volts.
66S&F AC box signle plie and neutral elcolsure with a two pin and socket complete with one single pole MCB 240 volts, 32 Amps
67S&F switch piano flush type, single pole, two way, 5 Amp, 230 Volts module type complete all as specified and directed.
68S&F socket outlet for 3 pin (with 2 pin outlet also), 5/6 Amp, flush type 240 Voltmodule type complete all as specified and directed.
69S&F socket outlet for 2 in 1, 3 pin 5 & 15 Amp, flush type 240 Volt module type complete all as specified and directed.
70S&Fmodular bell push , 5 Amp 240 Volts complete all as specified and directed.
71S&F bell/buzzer AC 230 Volts single pole complete all as specified and directed.
72S&F ceiling rose surface Bakelite 65x50mm two or three terminals complete all as specified and directed.
73S&F LED 16 Watt ultra slim edge 2x2 feet lit panel in aluminium casing recess mounted square fixture in white finsh suitable for low ceiling height, 3 in 1 , 3K, 4K, 6Kwith & including LED previred and connecting up dismantling of old unsv recessed mounted light.Make : Havells Cat Part No LHEXBHP71NW018or equivalent of Philips/ Crompton Greaves/Bajaj/Wipro.
74S&F in repair adore LED lamp 9/10 watt complete all as specified and directed. Make : Havell"s/Crompton/ Syska.
75Supply and fixing Adore LED lamp of 9/10 watt including taking down old u/s CFL lamp complete all as specified & directed. Make :- Havells cat part No. LHLDERHEML8X010or equivalent of Philips / Crompton Greaves / Wipro/Bajaj
76S&F stepped type electronic fan regulator, module type and connecting up ISI marked 240 volts complete all as specified & directed.
77S&F sheet metal enclosures, double door type, suitable for fixing MCB SPN with 200 Amps rated bus bar, 8 way, 240 volts complete all as specified and directed.
78Supply and fixing sheet metal enclosuressingle door type suitable for fixing MCB"s, SPN with 200 Amps rated bus bar,4 way, 240 Volts.
79S&F MCB 63 Amps, single pole & neutral, 240 Volts complete all as specified and directed. Make : Legrand/Havells/ABB
80S&F MCB 32 Amps, single pole & neutral, 240 Volts complete all as specified and directed. Make : Legrand/Havells/ABB
81S&F MCB 6-32 Amps, single pole, 240 Volts "C" curve, 10KA, ISI marked as per IS/IEC 60898-1 2002 complete all as specified and directed. Make : Legrand /Havells /ABB
82S&F sub main wiring on including passing throuh PVC conduit pipe 1100 volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 Sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to IS 694/1990 including taking down existing unserviceable sub main wiring.(Note : Two runs of cable with one run of earth wire and one run of PVC casing caping should measured as one length).
83Supply, laying, jointing and testing XLPE insulated, armoured,heavy duty LT underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 50 sqmm 3.5 core laid in trenches, along poles through pipes etc complete all as specified & as directed.Note : (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately including taking down old unserviceable XLPE cable. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
84M&L for brick work with fly ash bricks {As per IS-13757 (1993) burnt clay fly ash building bricks}, (Old size bricks) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection complete all as specified & directed.
85M&L dry sand (Tibba sand) and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
86M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/ Test point /panel / equipment and testing on including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed.
87Taking down & Refixing of ceiling fan complete of any sweep 240V, AC and connecting up with necessary wiring of 3 core flexble copper wire, complete all as specified and directed.
88Boring of holes under road, payment hard standing by trench less technology unsing ultra sound technique and necessary amchine including supply and fixing HPDE pipe of 80mm bore suitable for 0.4 mpa working pressure all as specified and directed
89S&F LED type street DRACO SERIES light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete all directed. Make :- C&S Cat Part No LTESS WLED or equvalent Crompton Freaves /Wipro
90S&F cubical metallic box of size 1.0 Mtr X 0.9 Mtr X 0.30 M depth made out of 2 mm thick mild steel sheet, fron openable double door type with locking arrangment with and including 3 mm tgick plain sheet clear glass of suitable size fixed to facilite meter reading, all internal and external steel surfaces painted wityh two costs of synthetic enamel paint over a coat of red oxide primer, internal wiring with PVC insulated single core multistranded copper conductor FRLS cable IS-694 marked of adequate size but not less than 6 Sq mm with proper ferrule and cable gland, box shall be fixed on wall with "Anchor" type/fastner type bolts & nuts (Set of 6 bolts of 12 mm dia 200mm long with nuts and washer) frouted into the wall properly to hold the box, writing MES/Qtr No for each energy meter with thick whit synthetic enamel paint, neoprene rubber gasket shall be provided for proper sealing, including bos shall have arrangement for fixing electric energy meter- 04 Nos, MCB DB SPN 2 way -04 Nos, MCB DB SPN 4 way -01 Nos complete all as dirtected. Note :-(a) Existing Electric meter -04 Nos will be taking doen carefully and refixing the same inside the new meter box carefully incl necessary electric connections and sealing the elcectric meter, and MCB DB SPN 4 Way and MCB DB SPN 2 Way shall be measured and paid for separately under relevent items of this dchedule. (b) The cubical box shall be fix inside (concelled) the existing wall by necessary cutting/frouting the wall and make good the distrubed surfaces be applying cement.
Disclaimer :